No Chromophore? No Problem! Universal HPLC Detection. The world leader in serving science

Similar documents
The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

Discover what you re missing

Corona Veo the Next Generation Charged Aerosol Detector

Agilent 385-ELSD Evaporative Light Scattering Detector

Charged Aerosol Detection 101

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

Agilent 385-ELSD Evaporative Light Scattering Detector

Sensitive HPLC Method for Triterpenoid Analysis Using Charged Aerosol Detection with Improved Resolution

Direct Analysis of Surfactants using HPLC with Charged Aerosol Detection

Selecting Detectors for Compounds with No Optical Absorbance

Quantitation of Surfactants in Samples by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

Charged Aerosol Detection and Evaporative Light Scattering Detection Fundamental Differences Affecting Analytical Performance

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Varian 385-LC. ELSD for Low Molecular Weight Compounds

Varian 380-LC. ELSD for Routine HPLC and GPC Analysis. Key Benefits

HPLC Analysis of Non-volatile Analytes Using

Agilent 1260 Infinity Evaporative Light Scattering Detector (ELSD)

Analysis of Silicone Oils by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

Quantitation and Characterization of Copper Plating Bath Additives by Liquid Chromatography with Charged Aerosol Detection

Evaporative Light Scattering Detector (ELSD)

Analysis of pharmaceuticals using HPLC with evaporative light scattering detection

Enhancement of Linearity and Response in Charged Aerosol Detection

HPLC Analysis of Nonvolatile Analytes Using Charged Aerosol Detection

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

Quantitation and Characterization of Copper and Nickel Plating Bath Additives by Liquid Chromatography

Shodex TM ODP2 HP series columns

Pharmaceutical Analysis of API and Counter Ions in Complex Formulations in a Single Injection

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Chapter content. Reference

High Performance Liquid Chromatography

High Performance Liquid Chromatography

LUMEFANTRINUM LUMEFANTRINE

Use of Charged Aerosol Detection as an Orthogonal Quantification Technique for Drug Metabolites in Safety Testing (MIST)

for Acclaim Mixed-Mode HILIC-1 Column

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

Advantages of polymerbased. an alternative for ODS

HPLC Column Selection: Solve the Separation Mystery. The world leader in serving science

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific

Selecting an LC/MS Interface Becky Wittrig, Ph.D.

Figure 1. Structures for Vitamin B2 and Vitamin B1.

High Performance Liquid Chromatography

CHAPTER V ANALYTICAL METHODS ESTIMATION OF DICLOFENAC. Diclofenac (gift sample from M/s Micro Labs Ltd., Pondicherry)

Figure 1. Structures for Vitamin B2 and Vitamin B1.

for Acclaim Trinity TM P1

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

High Pressure/Performance Liquid Chromatography (HPLC)

Tips & Tricks GPC/SEC: Quantify and Get More Than Molar Mass Averages

BRIEFING. Pharmacopeial Discussion Group Sign Off Document Attributes EP JP USP Definition Loss on drying Readily carbonizable substances

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Acclaim Mixed-Mode WCX-1

Chemistry Instrumental Analysis Lecture 27. Chem 4631

Determination of Caffeine by HPLC

H 3 CO H 3 CO S CH 3

CYCLOSERINE Final text for addition to The International Pharmacopoeia. (November 2008) CYCLOSERINUM CYCLOSERINE

9.1 Water. Chapter 9 Solutions. Water. Water in Foods

COLLIGATIVE PROPERTIES

APPLICATION NOTE Goal. Introduction. Keywords

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

AN INTRODUCTION TO ATOMIC SPECTROSCOPY

Packings for HPLC. Packings for HPLC

Comparison of different aqueous mobile phase HPLC techniques

Charged Aerosol Detection: Factors for consideration in its use as a generic quantitative detector

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Mechanisms of retention in HPLC

Chromatography. Chromatography is a combination of two words; * Chromo Meaning color * Graphy representation of something on paper (writing)

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Spectroscopy and Chromatography

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited


5072 CHEMISTRY (NEW PAPERS WITH SPA) TOPIC 1: EXPERIMENTAL CHEMISTRY 5067 CHEMISTRY (NEW PAPERS WITH PRACTICAL EXAM) TOPIC 1: EXPERIMENTAL CHEMISTRY

HPLC. High Performance Liquid Chromatography (HPLC) Harris Chapter 25

TEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD

Saccharides and Organic Acids

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Metoprolol and Select Impurities Analysis Using a Hydrophilic Interaction Chromatography Method with Combined UV and Charged Aerosol Detection

Expanded capabilities in ammonium and amine detection

Method Development with ZirChrom's Ion Exchange Phases

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

M M e M M H M M H. Ion Sources

What type of samples are common? Time spent on different operations during LC analyses. Number of samples? Aims. Sources of error. Sample preparation

Chromatography & instrumentation in Organic Chemistry

Analytical Methods to Qualify and Quantify PEG and PEGylated Biopharmaceuticals

ARTEMETHER AND LUMEFANTRINE ORAL SUSPENSION:Final text for addition to The International Pharmacopoeia (November 2008)

Lecture 4 : Gel Permeation or Size Exclusion Chromatography

CHM151 Quiz Pts Fall 2013 Name: Due at time of final exam. Provide explanations for your answers.

8. Methods in Developing Mobile Phase Condition for C18 Column

Open Column Chromatography, GC, TLC, and HPLC

A Novel LC-ELSD Method for the Quantification of 2-Deoxy D-Glucose Using HILIC Chromatography

Introduction to Pharmaceutical Chemical Analysis


CP Chapter 15/16 Solutions What Are Solutions?

ARTEMETHER AND LUMEFANTRINE TABLETS: Final text for addition to The International Pharmacopoeia (July 2008)

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

CHEMISTRY 31 FINAL EXAM - SOLUTIONS Dec. 10, points total

10/2/2008. hc λ. νλ =c. proportional to frequency. Energy is inversely proportional to wavelength And is directly proportional to wavenumber

Transcription:

No Chromophore? No Problem! Universal HPLC Detection The world leader in serving science

Topics Key concepts behind Thermo Scientific Charged Aerosol Detection (CAD) Universal Detection and Uniform Response How does CAD work? Recent Advances Use of Thermo Scientific Vanquish Duo and CAD for Relative Quantitation 2

Key Concepts Universal Detection Response for every component within eluent (except mobile phase) Discriminator is volatility (similar to ELSD) Eluents need to be volatile Detects all species that form stable (non-volatiles) or semi-stable (semi-volatiles) aerosol particles Does not rely on a chromophore or ability to form a gas phase ion (Unlike UV or MS) Enables a more comprehensive view of sample composition 3

Key Concepts Uniform Response Same response for all components independent of chemical structure Very desirable for many applications (i.e., when use of individual standards is not feasible) Drug libraries, synthetic mixtures Impurities and degradants Herbal medicines Natural products Polymers and surfactants Lipids Allows estimation of quantity 10.7% RSD variation in CAD response among a wide diversity of non-volatile analytes 4

Topics Key concepts behind Charged Aerosol Detection (CAD) Universal Detection and Uniform Response How does CAD work? Recent Advances Use of Vanquish Duo and CAD for Relative Quantitation 5

How Charged Aerosol Detection Works 3. Spray Chamber Larger droplets collide with surface Signal is directly proportional to the analyte quantity 10. Signal Out 2. Nebulizer Droplet spray formed 8. Ion Trap Excess gas ions / smaller charged particles removed 1.Inlet: Column Effluent and gas 4. Drain Condensed liquid removed 9. Collector Charge on analyte particles is measured by a sensitive electrometer 5. Drying Tube Droplets evaporate leaving dry particles 6. Corona Charger Gas is ionized - positive charge 7. Mixing Chamber Positive charge transferred to particles 6

Evaporative Aerosol Detection Pneumatic nebulizers create wide droplet size distribution Isocratic size distribution ~ constant throughout separation Solvent gradient size distribution changes with eluent viscosity and surface tension With less volatile eluents (e.g., aqueous) - largest droplets must be removed ( size cut ) Evaporation from remaining droplets produces a steady stream of dried particles Size of each particle depends on nonvolatile solute mass concentration in initial droplet 7

Droplet Evaporation Solutes that form stable particles - behave as nonvolatiles and should have similarly-shaped response curves Solutes that form less stable particles - behave as semivolatiles Lower overall response, non-linear drop at low end = shape of response curve is distinct from that of nonvolatiles Not fully predicted by boiling point, vapor pressure, etc. more complex Important to consider possible ionic interactions Evap T - more analytes behave as semivolatiles less uniform response 8

Response Curve Shape Peak Area (pa*min) Nonvolatiles - similarly-shaped response curves Semi-volatiles Higher exponent (b) supralinear, most pronounced at low end Smaller particles evaporate more quickly variability / imprecision Higher Evap T more analytes behave as semivolatiles 0.2 0.15 0.1 ultra RS SN 8038993: PF 1.0 from 091012 R² = 0.9996 0.05 R² = 0.9994 semivolatile 0 0 20 40 60 80 100 120-0.05 Mass (ng) 9

Particle Charging for Charged Aerosol Detection Particle size proportional to mass of analyte + background residue Each dried particle/ consists of multiple species Charged particle Charge per particle proportional to particle size independent of composition Charged particles are measured, not gas phase ions as in MS Ion jet Mixing Chamber 10

Response Uniformity Dependency of Response on Analyte Properties* ELSD Refractive index (RI), which may vary > 2-fold for analytes within expected RI range of 1.4 1.6 Absorbance and fluorescence: mainly when using a monochromatic (e.g., laser diode) light source CAD Only a minor dependence on particle dielectric constant ( ): 3 to 5% difference between NaCl ( = 3.3) and Ag ( = infinity) CNLSD Particle wettability and solubility with respect to the condensing fluid, usually water Several comparison studies* - CAD has been consistently shown to provide more analyte-independent response than ELSD Direct comparison: Similar experiments (to right) % RSD - CAD 8.0; CNLSD 39.0 * Gamache PH, editor. Charged Aerosol Detection for Liquid Chromatography and Related Separation Techniques. John Wiley & Sons; 2017 May 8 11

CAD Unipolar Diffusion Charging of Aerosol Particles Peak area[pa*min] D-Glucose L-Ascorbic Acid Fluorescin Cortisone Lactose Maltose a-d-methyl-glucoside Rhodamin800 Mefloquine Chloramphenicol Taurine Cephalexin Mevinolin Dopamine HCl Guanidine HCl Diclofenac SodiumSalt Guanine Folic acid Oxalic acid Size-dependent charge, effectively independent of particle (chemical) composition Uniform response for nonvolatiles in isocratic conditions 3 2.5 CAD Response, 0.5 µg by flow injection Salt formation Semi-volatile Ionic analytes + mobile phase additives = larger particles, higher response Semivolatiles lower response, preferential loss of smaller particles 2 1.5 1 0.5 0 Substances 12

Summary - Evaporative Aerosol Detectors Response of all EADs depends on upstream spraydrying process: Relative volatility / partitioning into condensed phase Solvent (gradients) change in mass transport to downstream detector Salt formation between ionizable analyte and additives Downstream aerosol detector of CAD has least dependency on dried particle composition enabling the most uniform response Photometer Nebulizer Drain Nebulizer Light source Evaporation Tube Evaporation Tube Filter - Electrometer Drain Charger 13

Topics Key concepts behind Charged Aerosol Detection (CAD) Universal Detection and Uniform Response How does CAD work? Recent Advances Use of Vanquish Duo and CAD for Relative Quantitation 14

CAD Technology Development Thermo Scientific Dionex Corona ultra RS Charged Aerosol Detector Corona ultra RS Thermo Scientific Veo and Vanquish Model CADs To Evaporation Tube Impactor Concentric Nebulizer Spray chamber Cross-flow Nebulizer Inlet Gas In (N 2 ) Drain 15

Particle Size Distributions Comparison of Designs Larger median size and higher [#] produced by newer CADs More sensitive to nonvolatile / semivolatile: analyte and impurities Semivolatiles larger particles are more stable 20% aq. CH 3 OH 1 µg/ml theophylline; 20% aq. CH 3 OH 10 µg/ml theophylline; 20% aq. CH 3 OH Corona ultra RS GMD: 5.0 nm [#/sec]: 0.13 x 10 9 GMD: 8.8 nm [#/sec]: 1.1 x 10 9 GMD: 12 nm [#/sec]: 8.5 x 10 9 Corona Veo RS GMD: 9.7 nm [#/sec]: 1.1 x 10 9 GMD: 19 nm [#/sec]: 3.6 x 10 9 GMD; - 26 nm [#/sec] n/a range exceeded SMPS spectrometer, TSI Model 3938, 1.0 ml/min liquid flow; GMD = geometric mean diameter. 16

CAD Technology Developments - Improved Sensitivity Theophylline Theophylline Caffeine Caffeine More sensitive detection of: Nonvolatiles (e.g., theophylline) Semi-volatiles (e.g., caffeine) at higher evap T (Veo 35 C, Ultra RS subambient due to evaporative cooling) Impurities nonvolatile and semi-volatile Best sensitivity limits with cleanest eluents Most uniform response with lowest Evap T 0.03 0.02 0.01 0.00 0.10 0.08 pa Veo RS Ultra RS 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 pa 0.5 ng 2.0 ng min 0.06 0.04 0.02 Veo RS 0.00 Ultra RS 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 min 17

Response Uniformity - CAD Peak area [pa*min] Flow injection analysis of 36 structurally diverse nonvolatile analytes Vanquish CAD, Evap T = 35 C Variance among analytes = 5.8% RSD Additional factors?: Purity of starting material (e.g., powder) Changes during preparation (e.g., water absorption) Weighing and dilution errors Analyte degradation, loss on column 3 2.5 2 1.5 1 0.5 0 CAD response to 0.5 µg by flow injection Dopamine Folic acid Guanidine Mevinolin Thiamine Cephalexin Succrose Bumetanid Acetaminophen D-Pantothenic acid Diuron Tetracaine Uridine Uracil Tripolidine Taurine Chloramphenicol Dibucaine Mefloquine Hippuric acid Rhodamin800 D-Fructose Saccharin a-d-methyl-glucoside Maltose Cortisone Diclofenac New coccine Fluorescin Lactose L-Ascorbic Acid L-Citruline D-Glucose Buspirone Guanine Malic acid 18

Topics Key concepts behind Charged Aerosol Detection (CAD) Universal Detection and Uniform Response How does CAD work? Recent Advances Use of Vanquish Duo and CAD for Relative Quantitation 19

Additives Choice of additive type and concentration simultaneously consider separation and detection requirements ph modifiers (acids and bases) Buffers (weak acid + conjugate base or weak base + conjugate acid) Ion-pairing reagents (acid or base with hydrophobic tail) Cl - + H + HCl volatile Cl - + NH 4+ NH 4 Cl nonvolatile Volatile additives can form less volatile salts with other ionic eluent components Analytes, other additives, impurities, sample matrix components Beneficial when Cl - is analyte Detrimental if impurity/ matrix component 20

Solvents - Gradients Higher mass transport for solvents with lower viscosity and surface tension Analyte - signal, less uniform response Impurities baseline signal, noise, drift 10 µg/ml theophylline CH 3 OH: 20% Impurities in weaker solvent (e.g., H 2 O) may concentrate on column resulting in peaks, artifacts, drift CH 3 OH: 80% Inverse gradient compensation - more uniform response, less drift Column bleed, impurities in weaker solvent still a concern Conventional Gradient Elution Inverse Gradient Compensation 21

Inverse Gradient Compensation Vanquish Duo for Inverse Gradient 22

Salt Formation - Influence on Ionic Analyte Response Volatile / semivolatile significant response increase and change in curve shape, toward that of nonvolatiles (decrease in exponent b) Nonvolatile ionized analytes no change in curve shape, smaller affect on response Use lowest practical evaporation T to achieve more uniform response Relative quantitation If extent of ionization and molar mass (M) are known: [(Peak Area x M analyte )/(M analyte + M additive )] Use low M additives (e.g., formic acid, ammonia) to minimize affect / achieve more uniform response Estimating quantity in the absence of individual standards Without inverse gradient compensation With inverse gradient compensation With inverse gradient compensation and correction for salt formation* *In 0.1 M acetic acid eluent, each analyte was assumed to have one fully ionized basic functional group 23

Summary CAD and other EADs have in common: Detection scope and eluent requirements Response dependency on Solvent composition Analyte volatility Salt formation for ionic solutes Downstream aerosol detector of CAD enables: Better detection limits Wider linear and dynamic ranges More uniform response Vanquish Duo for Inverse Gradient New Technology Even better detection limits More uniform response More flexibility by use of wider range of eluent flow rates and compositions Uniform response and relative quantitation Inverse gradient compensation Lowest practical evaporation temperature Accounting for effects of salt formation 24

Join the Fun! Cache a Chromeleon Game Use your mobile device to complete challenges and earn a Charlie Chromeleon plush toy! If you are playing, you have earned points for attending this seminar. Be sure to scan the barcode on the desk outside the door. Ask booth staff for more details on how to play. 25

Thank You Please join me in the Liquid Chromatography section of our booth where I ll address additional comments and questions. 26