Calculation of Bubble Detector Response Using Data from the Matroshka-R Study

Similar documents
ISSCREM: International Space Station Cosmic Radiation Exposure Model

Update on Calibration Studies of the Canadian High-Energy Neutron Spectrometry System (CHENSS)

Bubble-Detector Measurements for Matroshka-R and Radi-N2: ISS-51/52 and ISS-53/54

Bubble Detector Characterization for Space Radiation

Simulations of MATROSHKA-R experiment 2006 at the ISS using PHITS

František SPURNÝ, Iva JADRNÍCKOVÁ. Nuclear Physics Institute Department of Radiation Dosimetry, Academy of Sciences of the Czech Republic, Prague

Passive dosimetry in the Service (Zvezda) module: J.K. Pálfalvi1

In-Situ Estimation of Cosmic Radiation Exposure During High-Altitude, Long-Distance Commercial Flights

Preliminary results of SI2 experiment obtained by PADC track etch detectors J. Szabó, J. K. Pálfalvi, B. Dudás

Development of Active Space Radiation Detector, A-DREAMS-2 at NIRS

H. Koshiishi, H. Matsumoto, A. Chishiki, T. Goka, and T. Omodaka. Japan Aerospace Exploration Agency

Neutron dose assessments for MATROSHKA using the HPA PADC dosemeter

A Predictive Code for ISS Radiation Mission Planning

ICRP Symposium on the International System of Radiological Protection

Analysis of the EVA Doses Observed by Liulin-Type Instruments on ISS

(PHENS) for Active Diagnostics of Radiation Environment in Spacecraft

Space Radiation Dosimetry - Recent Measurements and Future Tasks

PHITS calculation of the radiation field in HIMAC BIO

Some problems to be solved for automatic analysis of a CR-39 nuclear track detector in space radiation

18-th Workshop on Radiation Monitoring for the International Space Station. 3-5 September 2013, Budapest, Hungary

Radiation Protection Dosimetry (2007), Vol. 126, No. 1 4, pp Advance Access publication 23 May 2007

ICRP Symposium on the International System of Radiological Protection

Republic. Sept. 3rd th WRMISS in Budapest 1

Requirements for Space Radiation Dosimetry Walter Schimmerling, Francis A. Cucinotta, and John W. Wilson

CRaTER Science Requirements

Department of Radiation Protection, Nuclear Science Research Institute, Japan Atomic Energy Agency

Neutron Metrology Activities at CIAE (2009~2010)

DOSIMETRY AND MICRODOSIMETRY ONBOARD ISS AND RELATED TOPICS František SPURNÝ, Iva JADRNÍČKOVÁ, Karel TUREK

Determination of the Neutron Component of the Cosmic Radiation Field in Spacecraft using a PADC Neutron Personal Dosemeter

Prairie View A&M University Center for Applied Radiation Research

DOSIMETRY ON THE FOTON M2/BIOPAN-5 SATELLITE

Dosimetry for space radiation in ISS lifescience experiments using PADLES system

Deep Space Test Bed. POC Deep Space Test Bed (DSTB)

Geant4 simulation of SOI microdosimetry for radiation protection in space and aviation environments

Portable, Low-cost Proportional Counters for Space, Atmospheric and Ground based Applications

PR157 Characterization of particle detectors and dosemeters used at flight altitudes and on space missions

High Dose Rates by Relativistic Electrons: Observations on Foton M2/M3 satellites and on International Space Station

NSRL-ICCHIBAN Brief Report, ICCHIBAN-7&8 Announcement and Future ICCHIBAN Experiments

Spectral Correction Factors for Conventional Neutron Dose Meters Used in High-Energy Neutron Environments

Contribution of the Nuclear Physics Institute of the AS CR to the BEOBAL Project

Fast-Neutron Production via Break-Up of Deuterons and Fast-Neutron Dosimetry

Neutron dosimetry and microdosimetry with track etch based LET spectrometer

Geant4 Based Space Radiation Application for Planar and Spherical Geometries

Characterization of the 3 MeV Neutron Field for the Monoenergetic Fast Neutron Fluence Standard at the National Metrology Institute of Japan

Calculation of Cosmic Radiation Exposure of Aircrew: PCAIRE Code

SPACE DOSIMETRY WITH A 3D SILICON DETECTOR TELESCOPE

Measuring dose equivalent in an aviation environment using PIN diodes

InterComparison for Cosmic-ray with Heavy Ion Beams At NIRS

Secondary Particles Produced by Hadron Therapy

International Journal of Scientific & Engineering Research, Volume 7, Issue 2, February-2016 ISSN

Recent Radiation Monitoring Results: Expedition 10, 11 and STS-114


Neutron and/or photon response of a TLD-albedo personal dosemeter on an ISO slab phantom

Influence of Sensitive Volume Dimensions on the Distribution of Energy Transferred by Charged Particles

Secondary Neutron Dose Measurement for Proton Line Scanning Therapy

Estimation of Radioactivity and Residual Gamma-ray Dose around a Collimator at 3-GeV Proton Synchrotron Ring of J-PARC Facility

Energy Response Characteristics of Several Neutron Measuring Devices Determined By Using the Scattered Neutron Calibration Fields of KAERI

Personal Dose Monitoring System

Development of a Passive Dosimeter for Life Science Experiments in Space (PADLES) in NASDA

APPLICATION OF POLYMERIC NANO COMPOSITES AT LOW EARTH ORBIT AND GEOSYNCHRONOUS EARTH ORBIT

IAC-08-A MONTE CARLO SIMULATIONS OF ENERGY LOSSES BY SPACE PROTONS IN THE CRATER DETECTOR

Laboratoire National Henri Becquerel (CEA/LIST/LNHB), France (2) ENEA-Radiation Protection Institute, Bologna, Italy (3)

THE ACTIVE PERSONNEL DOSIMETER - APFEL ENTERPRISES SUPERHEATED DROP DETECTOR*

Energy response for high-energy neutrons of multi-functional electronic personal dosemeter

Introduction. Neutron Effects NSEU. Neutron Testing Basics User Requirements Conclusions

Advacam, Prague, Czech Republic. Nuclear Physics Institute, Czech Academy of Sciences, Prague, Czech Republic

Fluence-to-Dose Conversion Coefficients for Muons and Pions Calculated Based on ICRP Publication 103 Using the PHITS Code

Validation of the UFS Bonner Sphere Spectrometer and Monte Carlo Methods at the CERN-EU high energy Reference Field (CERF)

November 2013 analysis of high energy electrons on the Japan Experimental Module (JEM: Kibo)

Lunar Exploration Initiative. Ionizing Radiation on the Moon David A. Kring

Volume 1 No. 4, October 2011 ISSN International Journal of Science and Technology IJST Journal. All rights reserved

PECULIARITIES OF FORMING THE RADIATION SITUATION AT AN AREA OF NSC KIPT ACCELERATORS LOCATION

THE NEWEST HUNGARIAN COSMIC RADIATION MEASUREMENT RESULTS IN THE STRATOSPHERE USING STRATOSPHERIC BALLOONS AND SOUNDING ROCKETS

Tritel: 3D Silicon Detector Telescope used for Space Dosimetry. Tamás Pázmándi, Attila Hirn, Sándor Deme, István Apáthy, Antal Csőke, *László Bodnár

GCR Methods in Radiation Transport. F.A. Cucinotta And M.Y. Kim NASA Johnson Space Center

An extremity (wrist) dosemeter based on the Landauer InLight TM whole body dosemeter

The Cosmic Ray Telescope for the Effects of Radiation (CRaTER) Investigation for the Lunar Reconnaissance Orbiter

CHARACTERIZATION OF A RADIATION DETECTOR FOR AIRCRAFT MEASUREMENTS

Solar Particle Effects in Aircrew Dosimetry

D E S I R E Dose Estimation by Simulation of the ISS Radiation Environment

ICALEPCS Oct. 6-11, 2013

R&D of emulsion technology to study fragment interaction to improve ion therapy

Activation of Air and Concrete in Medical Isotope Production Cyclotron Facilities

CRaTER Pre-Ship Review (PSR) Instrument Calibration Science Requirements Compliance

MARE International Payload aboard Orion EM-1 Status Update for 23rd WRMISS

THESIS MICRODOSIMETRIC MEASUREMENTS OF SHIELDING EFFECTS FOR IRON PARTICLES AT 500 MEY/NUCLEON INCIDENT UPON ALUMINUM AND POLYETHYLENE

Lead shielding impact on fast neutron spectrum (>10MeV) in QUINTA uranium target.

Solar Particle Events in Aviation and Space. Günther Reitz Insitute of Aerospace Medicine German Aerospace Center, DLR, Cologne, Germany

Part E. Radiation monitors. Radiation Safety - JUAS 2014, X. Queralt. Part E. Radiation monitors

Radiation Transport Tools for Space Applications: A Review

POSTER EVIDENCE FOR FAST NEUTRON EMISSION DURING SRI S SPAWAR/GALILEO TYPE ELECTROLYSIS EXPERIMENTS #7 AND #5, BASED ON CR-39 TRACK DETECTOR RECORD

SIMULATIONS OF SPACE RADIATION INTERACTIONS WITH MATERIALS AND DOSE ESTIMATES FOR A LUNAR SHELTER AND ABOARD THE INTERNATIONAL SPACE STATION

ESTIMATION OF 90 SCATTERING COEFFICIENT IN THE SHIELDING CALCULATION OF DIAGNOSTIC X-RAY EQUIPMENT

Radiation Shielding Simulation For Interplanetary Manned Missions

Chapter V: Cavity theories

Simultaneous Investigation of Galactic Cosmic Rays on Aircrafts and on International Space Station

Radiation Shielding Simulation For Interplanetary Manned Missions

Probing the sub-disciplines: what do we know? what do we need to know? The physics The chemistry - Modelling

Bonner Sphere Spectrometer. Cruzate, J.A.; Carelli, J.L. and Gregori, B.N.

Simulation of light ion transport in a water phantom using Geant4.

Transcription:

Calculation of Bubble Detector Response Using Data from the Matroshka-R Study B. J. Lewis 1, T. Matthews 2, S. El-Jaby 1, L. Tomi 2, M. Smith 3, H. Ing 3, H.R. Andrews 3, V. Shurshakov 4, I. Tchernykh 4 1 Royal Military College 2 Canadian Space Agency 3 Bubble Technology Industries 4 Institute of Biomedical Problems 15 th WRMISS Workshop Radiation Monitoring for the International Space Station September 7-9 2010

Motivation In 2009, WRMISS asked Canadian Space Agency to prepare an overview paper on Bubble Detector Technology which would: Highlight all the work and previous publications on Bubble Detector technology Summarize data on Bubble Detector response to neutrons, protons, and HZE particles.

1 of 19 OUTLINE Introduction Bubble Detector Characterization Studies Mission Applications Russian Matroshka-R Session 8 : Proton and Neutron Studies Session 7 : Heavy Ion Studies Contributions of Protons, Neutrons, and Heavy Ions to Bubble Count Conclusions

Introduction 2 of 19 Neutron Dosimetry in Space Bubble Detector *NASA, ROSAT Guest Observer Facility, 2002 (http://heasarc.gsfc.nasa.gov/docs/rosat/gallery/misc_saad.html) There exists a complex particle and neutron field in space. Albedo neutrons from Earth s atmosphere and secondary production from spacecraft shielding contributes ~10-30% of total dose equivalent. TEPC reliable doses <20 MeV (response to higher energies?) CR-39 passive dosimeters complement TEPC (and TLDs)

Introduction 3 of 19 Bubble Detector Experimental Apparatus Space bubble detectors (SBD s) Used in space applications since 1989, including Russian Matroshka-R (2006,-2008) Test-tube-shaped neutron dosimeter developed by Bubble Technology Industries Inc. (BTI) Microscopic liquid droplets form bubbles of trapped gas upon contact with neutrons. Number of bubbles can be auto-counted using a reader and is indicative of the neutron radiation field intensity.

Introduction 4 of 19 Experimental Apparatus Bubble reader aboard the ISS Russian Segment Source: Bubble Technology Industries http://www.bubbletech.ca/radiation_detectors_files/bdr.html

5 of 19 Bubble Detector Neutrons Characterization Studies Protons and Heavy Ions Neutrons Defence Research and Development Canada Ottawa (DRDC-O) [1980 s] National Institute of Standards and Technology (NIST) [1990] Thermal Neutrons (144 kev) National Physical Laboratory (NPL) Van de Graff Accelerator [1990] 7 Li(p,n) 0.033 to 0.627 MeV T(p,n) 0.214 to 2.22 MeV D(d,n) 2.03 to 5.26 MeV T(d,n) 13 to 18 MeV CERN/European Commission High Energy Reference Field (CERF) [2002] Simulated space spectrum Integral neutron field ithemba [2007] High energy neutrons (100 and 200 MeV)

6 of 19 Bubble detector Protons and Heavy Ions Characterization Studies Protons Tri-University Meson Facility (TRIUMF) [2003] 81.7 MeV (as protons entered experimental apparatus) 77 MeV (as protons entered the detector) National Institute of Radiological Sciences (NIRS) [2004] 35, 50 and 70 MeV Heavy Ions Heavy Ion Medical Accelerator in Chiba (HIMAC) [2006] Irradiated with N, Kr and Ar ions at 180, 400, and 500 MeV/u respectively.

7 of 19 Matroshka-R Experiments Performed over a series of experimental sessions ISS-13 (Sessions 1 & 2) [2006] ISS-14 (Sessions 3 and 4) [2007] ISS-15 (Sessions 5, 6 and 7) [2007/2008] ISS-16 (Sessions 8 and 9) [2008] Experiments performed using a spherical phantom with detectors placed on inside and outside of sphere.

Matroshka-R Experiments 8 of 19 Detector Locations for Sessions 7 and 8 Session 7 (ISS-15) : phantom placed in the Russian docking module B01, B02, B03 placed on surface of phantom B04 located behind the phantom on outer wall of the cabin B05, B06 located on internal wall of cabin Session 8 (ISS-16) : phantom place in the Russian PIRS module B01, B02, B03 gelled to the surface of phantom B04 located in the service module (SM) starboard cabin B06, B07 were located in the SM, close to the astronaut working desk B08 located in the SM (on the ceiling by the R16 radiometer)

9 of 19 Matroshka-R Experiments Measurements for Sessions 7 and 8 Matroshka-R Results for Session 7 Detector Label B01 B02 B03 B04 B05 B06 Sensitivity (bubble/µsv) 0.123 0.117 0.111 0.111 0.099 0.093 Exposure Time (s) 6.09E+05 6.09E+05 6.08E+05 6.08E+05 6.09E+05 6.09E+05 Number of bubbles 99 98 94 106 104 71 Dose (µsv) 803 838 845 951 993 697 Dose Rate (µsv/day) 114 119 120 135 141 99 Maschrafi et al., Neutron Dose Study With Bubble Detectors Aboard the International Space Station as part of the Matroshka-R Experiment, Radiation Protection Dosimetry, Advance Access Publication, Vol. 133, No. 4, pp. 200-207, 2009 Matroshka-R Results for Session 8 Detector Label B01 B02 B03 B04 B06 B07 B08 Sensitivity (bubble/µsv) 0.123 0.117 0.111 0.111 0.099 0.093 0.086 Exposure Time (s) 4.47E+05 4.47E+05 4.47E+05 4.47E+05 4.47E+05 4.47E+05 4.47E+05 Number of bubbles 72 71 64 105 73 71 48 Dose (µsv) 585 605 574 947 740 766 554 Dose Rate (µsv/day) 113 117 111 183 143 148 107 Internal Report: Bubble Technology Industries Inc. (2009). Matroshka R Experiment Phase 2. Chalk River, ON, Canada: Bubble Techology Industries Inc.

10 of 19 Analysis Particle flux estimate (CREME96 with shielding function) Differential flux: neutrons, protons and heavy ions (He, N, O and Ar) Integrated differential flux: Neutrons (0.25 100 MeV) 1.70 x 10 5 neutrons/cm 2 /s Protons (10 MeV 100 GeV) 6.3 x 10 5 protons/cm 2 /s Detector sensitivity S d (bubbles/µsv) Particle sensitivity S p,n (b/(particle/cm 2 )/(b/µsv)) Experiment duration, t (s) 4π particle incidence Shielding Function *Bubble Technology Industries, Matroshka-R Experiment Phase 2 - FINAL REPORT, August 10, 2010

11 of 19 Neutron and Charged Particle Spectra ϕ n,p (E) *Koshiishi et al, Evaluation of the Neutron Radiation Environment Inside the International Space Station Based on Bonner Ball Neutron Detector Experiment, Radiation Measurements, 2007, 1510-1520 *Charged particle differential flux from CREME96

12 of 19 Calculation Methodology Rate of bubble formation for protons (bubble/s) N& b = 4π S E d E upper ϕ ( E) S lower p p ( E) de ~ 4π S 100 GeV d 10 MeV ϕ( E) S p ( E) E Proton sensitivity (energy independent): S p = 5.0 x 10-6 b/(p/cm 2 )/(b/μsv)* Lower energy limit of 10 MeV (Proton penetration through detector shell) *H. Ing and A. Mortimer, Advances in Space Research (1993)

13 of 19 Calculation Methodology Protons contribute <1% to overall bubble count: 4πS p Σ [φ p (E) E] (b/(b/µsv)/s) Detector Label S d (b/µsv) N p (bubbles/ s) Time (s) N (bubbles from protons) # of bubbles determined from BTI Report Proton Contribution % 4.49E-06 B01 0.123 5.52E-07 4.47E+05 0.25 72 0.34 4.49E-06 B02 0.117 5.25E-07 4.47E+05 0.23 71 0.33 4.49E-06 B03 0.111 4.98E-07 4.47E+05 0.22 64 0.35 4.49E-06 B04 0.111 4.98E-07 4.47E+05 0.22 105 0.21 4.49E-06 B06 0.099 4.44E-07 4.47E+05 0.20 73 0.27 4.49E-06 B07 0.093 4.17E-07 4.47E+05 0.19 71 0.26 4.49E-06 B08 0.086 3.86E-07 4.47E+05 0.17 48 0.36 Mean: 0.21 72 0.30 Comparable results of ~1% using Takada response function for S p * *Takada et al, Measured Proton Sensitivities of Bubble Detectors, Radiation Protection Dosimetry, Vol. 111 (2), 181-189)

14 of 19 Neutron Response Function (S n (E)) High energy neutron sensitivities data collected at ithemba during experiments in 2007 Values averaged based on results of calibrations performed for the Radi N study in 2009 and 2010 *Bubble Technology Industries, Report on Characterization of the Space Bubble Detector Spectrometer, March 31st 2010 (Detector sensitivity of 0.1 bubble µsv -1 )

15 of 19 Predicted Versus Measured Bubble Count for Neutrons (Matroshka-R Session 8) 4πΣ [φ n (E) * Sn(E)* E] (b/(b/µsv)/s) N& b = 4π S Detector Label E d E upper ϕ ( E) S lower n Detector Sensitivity S d (b/µsv) n ( E) de ~ 4π S # of Bubbles/s 100 MeV d n 0.25 MeV Time Elapsed (s) ϕ ( E) S n ( E) E Total # of Bubbles due to Neutrons Bubble Count during Matroshka-R Measured Value/ Predicted Value 7.57E-04 B01 0.123 9.31E-05 447000 42 72 1.73 7.57E-04 B02 0.117 8.86E-05 447000 40 71 1.79 7.57E-04 B03 0.111 8.41E-05 447000 38 64 1.70 7.57E-04 B04 0.111 8.41E-05 447000 38 105 2.79 7.57E-04 B06 0.099 7.50E-05 447000 34 73 2.18 7.57E-04 B07 0.093 7.04E-05 447000 31 71 2.26 7.57E-04 B08 0.086 6.51E-05 447000 29 48 1.65 Mean: 0.106 Mean: 36 72 2.01 Reasonable agreement of number of bubbles predicted using neutron differential spectra from Koshiishi et al. with Matroshka measurement (factor of ~2 ).

16 of 19 Heavy Ion Contributions Calculations for Linear Energy Transfer (LET) P bf (x) = 1 e (-nσx) n = # of droplets per cm 3 (active volume of detector) σ = cross section of droplet x = critical distance the particle travels above threshold Considers minimum and maximum energy to enter and pass completely through detector Calculations for Nuclear Interaction X + 19 F interactions (scaled to p + 19 F) to determine heavy ion sensitivities σ pt = πr o ((A p ) 1/3 + ((A T ) 1/3 -b) 1/2 σ pt is cross section for interaction of projectile (p) and target (T) nuclei A p,t is the mass number b is the overlap parameter b = 1.56 0.2((A p ) 1/3 + ((A T ) 1/3 ) 2

17 of 19 Heavy Ion Calculation : LET Heavy ions contribute ~ 0.02% to overall bubble count due effect of linear energy transfer (LET): Element Ion Mass Matroshka-R Results for Session 7 Detector Label B01 B02 B03 B04 B05 B06 Sensitivity (bubble/µsv) 0.123 0.117 0.111 0.111 0.099 0.093 Exposure Time (s) 6.09E+05 6.09E+05 6.08E+05 6.08E+05 6.09E+05 6.09E+05 Number of bubbles 99 98 94 106 104 71 Dose (µsv) 803 838 845 951 993 697 Dose Rate (µsv/day) 114 119 120 135 141 99 Min Energy* (MeV) Min Energy (MeV/nuc) *Bubble Technology Industries, Matroshka-R Experiment Phase 2 - FINAL REPORT, March 31st 2009, Revised: August 10th 2010 Heavy Ion Contribution for Detector B01: Max Energy** (MeV) Max Energy (MeV/nuc) Critical Distance (cm) Bubble Formation Probability 4πΣ of Integrated Flux (particles/cm 2 /s) Flux Ions (/s) Bubbles due to Ions Observed Bubbles Bubbles due to Ions (%) He 4 35 8.75 150 150 0.0035 1.88E-05 6.33E-05 3.37E-04 3.85E-03 99 0.00389 N 14 250 17.86 1000 71.43 0.121 6.50E-04 1.25E-06 6.66E-06 2.63E-03 99 0.00266 O 16 300 18.75 1300 81.25 0.181 9.72E-04 3.93E-06 2.09E-05 1.24E-02 99 0.01249 Ar 40 1100 27.5 5000 125 0.859 4.60E-03 1.52E-07 8.10E-07 2.27E-03 99 0.00229 *Energy required to enter the detector **Energy required to travel at least the length of the detector Sum: 0.02133

18 of 19 Heavy Ion Calculation : Nuclear Interaction Heavy ions contribute ~ 0.03% to overall bubble count due effect of nuclear interactions: Element Matroshka-R Results for Session 7 Detector Label B01 B02 B03 B04 B05 B06 Sensitivity (bubble/µsv) 0.123 0.117 0.111 0.111 0.099 0.093 Exposure Time (s) 6.09E+05 6.09E+05 6.08E+05 6.08E+05 6.09E+05 6.09E+05 Number of bubbles 99 98 94 106 104 71 Dose (µsv) 803 838 845 951 993 697 Dose Rate (µsv/day) 114 119 120 135 141 99 Σ of Integrated Flux (particles/cm 2 /s) Ion Sensitivity (bubble/(bubble/usv)(p article/cm2)) Sensitivity to Neutrons (bubble/usv) *Bubble Technology Industries, Matroshka-R Experiment Phase 2 - FINAL REPORT, March 31st 2009, Revised: August 10th 2010 Heavy Ion Contribution for Detector B01: Bubbles due to Ions (/s) Measurement Time (s) Bubbles due to Ions Observed Bubbles Nuclear Interaction Contribution to Bubble Count (%) He 4.55E-02 8.66E-06 0.123 4.84E-08 6.09E+05 0.0295 99 0.02978 N 3.07E-04 1.63E-05 0.123 6.17E-10 6.09E+05 0.0004 99 0.00038 O 8.36E-04 1.76E-05 0.123 1.81E-09 6.09E+05 0.0011 99 0.00111 Ar 1.45E-05 3.10E-05 0.123 5.52E-11 6.09E+05 0.0000 99 0.00003 Sum: 0.03131

19 of 19 Summary The passive BD dosimeter developed in Canada has been used for neutron radiation monitoring in space since 1989 During 2006-2008, BDs have been used in the Russian Matroshka-R study aboard International Space Station (ISS) during four expeditions (ISS-13, -14, -15 and -16). Using response data for neutrons, protons and heavy ions, based on comprehensive review of all literature bubble-detector data, along with differential-flux data calculated using the CREME code, calculations performed to determine contribution of charged particles to bubble formation Charged particles have a negligible overall contribution to the bubble count (< 0.5%)

Key Points Protons below 10 MeV cannot penetrate the shell of the detector (SRIM Calculation) We have an isotropic flux in space (4π) We have come at the response function in two separate ways We also folded in the response function measured at HIMAC by Takada (differential flux derived with CREME96 with an appropriate shielding function (RUSSIAN) for charged particle spectrum + heavy ions We used the same methedology for neutrons and simply substituted in a differential flux measured with Bonner Sphere balls measured by the Japanese and a response function extended to high energy based on 100 and 200 MeV measurements at ithemba (got factor of 2)