OVL FLOWMETER Meter Size:,,,, ( Single ase onstruction ) Pocketless Design GENERL SPEIFITION GS.No.GBB--E GENERL The OVL flowmeter is a positive displacement type flowmeter comprising a pair of oval gear rotors. It is capable of metering the actual quantity of the material passing through it with a high degree of precision over a wide flow range and accepts any liquid irrespective of its chemical or physical properties. It s accuracy, reliability, and quality has made it a highly valued industrial instrument. FETURES. Pocketless design of the measuring chamber does not cause accumulation of metered material and also makes this meter easy to disassemble.. Simple construction allows for easy maintenance and inspection.. ompatible with a variety of pulse generators that allows a wide selection of remote instrumentation.. an accept liquids of widely varying chemical properties by selecting appropriate meter materials.. vailable to wide range of operating temperature and pressure. GENERL SPEIFITIONS Meter Body Item Description Meter size Nominal size mm 8 ( ) ( ) ( ), ( ) ( ), (8 ) onstruction Single case construction, pocketless design pplicable fluid Water, petroleum's, liquid food, chemical liquids in general, etc. Flow range See flow range table (P.) Operating temp. ±.% ~+ Linearity range ±.% ~+ Linearity ±.% or ±.% Repeatability ±.% or ±.% Outer housing SS Material Inner housing, Rotor SUS or SUSL Bearing arbon or ceramic Flow direction Right Left (st'd.), Left Right, Bottom Top, Top Bottom Finish Body, Transmission Gear Box & Register ase:munsell.g 8/ Register Frame: Munsell N. special Flange Ratings and Max. Operating Pressures: MPa Pressure Rating Housing Material K SS K SS NOTE: Reference temperature;. Flange Rating JIS Flange Rating NSI lass.8..8.. OVL orporation Head Office: Tokyo; Tel. 8---. Fax 8---8 Beijing Office: Tel., Fax. 8---. Tel. 8--- Overseas Branch Offices: Seoul. Singapore. Taipei http: www.oval.co.jp
FLOW RNGE Table Flow Range for Liquid in General (Linearity : ±.%) (Operating temp. range : ~+ ) Meter Size Water Water Liquids other than water (Unit in mpa s) max. ~ less than..~.8.8~ ~ ~ ~ ~ ontinuous 8 ~ ~ ~ ~ 8 ~ ~ ~ ~ ~ 8 Intermittent 8 ~ ~ ~ ~ 8 ~ ~ ~ ~ ~.I.F. 8 ontinuous ~ ~ ~ 8 ~ 8 ~ 8 8 ~ ~ ~ ~ Intermittent ~ ~ ~ ~ ~ 8 ~ ~ ~ ~.I.F. ontinuous ~ ~ ~ ~ ~ ~ 8 ~ 8 ~ ~ Intermittent ~ ~ ~ ~ ~ ~ ~ ~ ~.I.F. ontinuous ~ ~ ~ 8 ~ 8 ~ 8 ~ ~ ~ ~ Intermittent ~ ~ ~ ~ ~ ~ ~ ~ ~.I.F. ontinuous ~ ~ 8 8 ~ ~ ~ ~ ~ ~ ~ 8 Intermittent ~ ~ 8 ~ 8 ~ 8 ~ 8 ~ ~ ~ 8 ~.I.F. 8 Table B Flow Range for Liquid in General (Linearity : ±.%) (Operating temp. range : ~+ ) Meter Size Nom. size mm Nom. size mm Type of Liquid Temp. Viscosity Range Operating ondition Type of Liquid Temp. Viscosity Range Operating ondition Liquids other than water (Unit in mpa s) Unit in m /h Unit in m /h max. less than..~.8.8~ ~ ~ ~ ~ ontinuous ~ ~ ~ ~ ~ ~ ~ ~ 8 Intermittent ~ ~ ~ ~ ~ ~ ~ ~.I.F. 8 ontinuous ~ ~ 8 ~ 8 ~ 8 ~ 8 ~ 8 ~ 8 ~ Intermittent ~ ~ ~ ~ ~ 8 ~ 8 ~ 8 ~.I.F. ontinuous ~ ~ ~ ~ ~ 8 ~ 8 ~ ~ Intermittent ~ ~ ~ ~ ~ ~ ~ ~.I.F. ontinuous ~ ~ 8 ~ 8 ~ 8 ~ ~ ~ ~ Intermittent ~ ~ ~ ~ ~ ~ ~ ~.I.F. ontinuous ~ ~ 8 ~ ~ ~ ~ ~ ~ 8 Intermittent ~ ~ 8 8 ~ 8 ~ 8 ~ ~ ~ 8 ~.I.F. 8 NOTES: l. In the Operating ondition column ontinuous means continuous operation; Intermittent means no more than 8 hours operating a day, and.i.f. indicates allowable instantaneous flow rate.. Flow range should be selected within the ontinuous or Intermittent range specified.. For applications where viscosity exceeds mpa s, specially machined rotors are used.. Regarding special chemical liquid (liquid ammonia, nitric acid, ammonium sulfate, chlorosulfonic acid, fuming sulfuric acid, sulfuric acid) and highly viscous liquids in excess of mpa s, consult factory.. Regarding liquid ammonia, consult factory.. : Special REGISTERS ND UNIT REGISTRTION Register Model Direct-reading Register (LW) Direct-reading Register w/reset ounter (LW) Resettable Register (LW) Resettable Register w/printer ombination (LW) Dial and Pointer Total ounter Volume per Point Rev. (L) Min. Reading (L) Max. Readout (L) LSD Drum (L) 8 8 (Output Shaft) (Output Shaft) (Output Shaft) (Output Shaft) (Output Shaft) (Output Shaft) s to general specifications of registers, refer to individual General Specification Sheets. (LSD: Least Significant Digit)
Unit of Factored Pulse Generated Unit of Unfactored Pulse Generation Volume per Pointer Rev. L/rev. Meter Size Generator Pulse No. Signal Unit (L/P) P / rev. PG - PGS Freq. at Max. (Hz).... (L/P) P / rev. Freq. at Max. (Hz).... : Standard For detailed pulse generator specifications, see individual General Specification Sheets. Full Scale for Indicator or Recorder (L/P) P / rev. PG - PGD Freq. at Max. (Hz) Max. m /h PGS Nominal Meter Factor (ml/p) Less than Full Scale (m /h). () 8. ().8 (). () 8. () More than Full Scale (m /h) Meter Size Full Scale m /h Full Scale L/min. 8 8 8 8 8 8 8.... P / rev. (L/P).... Freq. at Max. (Hz)........... 8...88...... ().8 () (). (8) 88.8 () METER ERROR and PRESSURE LOSS Meter Error % +.. Pressure Drop kpa Gasoline.mPa s Water mpa s Gas Oil mpa s Fuel Oil mpa s Meter Size Meter Size Meter Size Meter Size Meter Size 8 8 8 8 8 m /h
OVL MODEL EL REGISTERS ND REMOTE INSTRUMENTTION SYSTEMS Direct-coupled Registers and Remote Instrumentation System with Pulse Generator Equipped Totalizer EL EL Batch ontroller EL8 Batch ontroller EL8 Series Blender EL Series Multiple Temp. ompensator EL Series 8 Digital ontroller PG Pulse Generator (ontact-closure) PG, PGD, PGS, Voltage Pulse Generator LW Register 8 LW Register Factored Pulse Generation Basic Flowmeter Unfactored Pulse Generation onvenient Type ccuracy djustor (F) Fixed Type ccuracy djustor (G) 8 PG S F/I onverter onverter/ ompensator SU SU EL8 Indicator EL Recorder ontroller, nalog Instrument Direct-coupled Registers without Pulse Generator LW Registser 8 LW Register 8 LW, Register Basic Flowmeter NOTES:. For details of the direct-coupled registers, pulse generators, receiving instruments, etc., see individual General Specification sheets.. Explosionproof construction of pulse generators are available.
DIMENSIONS Meter Size: (LW Register Installed) Unit in mm a: Transmission Gear Box w/external ccuracy djustor (GB- ) b: Transmission Gear Box w/built-in ccuracy djustor (GB-) Symbol L F R D Flange Rating a b JIS K FF,RF JIS K RF,RF 8 8 8 8 NSI RFF 8 * In case of cooling fin, add mm to F above. Mass kg 8.. DIMENSIONS Meter Size: (LW Register Installed) Unit in mm a: Transmission Gear Box w/external ccuracy djustor (GB- ) b: Transmission Gear Box w/built-in ccuracy djustor (GB-) Symbol L F R Flange ratings a b JIS K FF... JIS K RF. 8.. NS RF... * In case of cooling fin coupled, add mm to F above. Mass kg 8
DIMENSIONS Meter Size: (LW Register Installed) Unit in mm ;;; a: Transmission Gear Box w/external ccuracy djustor (GB- ) b: Transmission Gear Box w/built-in ccuracy djustor (GB-) Symbol L F R D Flange Rating a b JIS K FF JIS K RF NSI RF * In case of cooling fin coupled, add mm to F above. Mass kg DIMENSIONS Meter Size:, (LW Register Installed) Unit in mm a: Transmission Gear Box w/external ccuracy djustor (GB- ) b: Transmission Gear Box w/built-in ccuracy djustor (GB-) Symbol L F R D Meter Size a b Mass kg JIS K RF 8 NSI FF 8 8 8 JIS K RF NSI FF 8 8 * In case of cooling fin coupled, add mm to F above.
MODEL ODE NUMBER Item pplication L Material of Metering Element Meter Size Meter onstruction and Flange Bore Direction-coupled Register ccuracy djustor and Mounting daptor Item Housing Material Basic Meter Register ode No. _ 8 Description Liquid service flowmeter SS (stainless steel casting) E SUS L(Rotors) Large Size Small Size Nominal size 8mm Nominal size mm Nominal sizemm Nominal size mm (Special) Nominal size mm Nominal size mm (Special) Nominal size mm Nominal size mm (Special) _ Single case construction (Small Size) (Special) _ Single case connection (Large Size) Direct-reading register (LW) Direct-reading register w/reset counter (LW) Resettable register (LW) Resettable register/printer combination (LW), ccumulative type Fixed type adjustor G or G provided onvenient type adjustor F provided ngle adaptor + Fixed type adjustor G or G provided ngle adaptor + onvenient type adjuster F provided ooling fin + Fixed type adjustor G or G provided ooling fin + onvenient type adjustor F provided Other rd Group Basic Meter B Generator ode No. _ SS (Stainless steel casting) Pressure Nominal pressure K (JIS K; NSI ) Rating Nominal pressure K (JIS K; JIS K) arbon plain bearings Bearings eramic bearings Transmission System _ Unfactored Pulse Generation D Factored Pulse Generation Mechanical Temperature ompensator and Pulse Generator ombination st Group nd Group th Group B D B D Description (ngle adaptor is used to mount LW, LW register at angle) (ooling fin is used in applications where operating temp. exceeds 8 and PG or PGS pulse generator is added.) Magnetic coupling (inserted into rotor and hollow shaft) Where pulse generator is not required. PGS voltage pulse ( VD, wires) PGSEP (flameproof construction) voltage pulse ( VD, Wires) PGD Non contact pulse ( VD, wires) PGDEP EP type Non contact pulse ( VD, wires) Others Where pulse generator is not required. PG voltage pulse ( VD, wires) PGEP (flameproof construction) voltage pulse ( VD, wires) PGS voltage pulse ( VD, wires) PGSEP (flameproof construction) voltage pulse (VD, wires) PG ontact pulse (Dry read switch) PGEP ontact pulse (Dry read switch) PGD Non contact pulse ( VD, wires) PGDEP EP type Non contact pulse ( VD, wires) Others Where mechanical temp. compensator is not required. Mechanical temp. compensator (T) provided. Where factored pulse is required upon mechanical temp.compensation (T + PG) Where factored pulse is required upon mechanical temp.compensation (T + PGEP) Where factored pulse is required upon mechanical temp.compensation (T + PGS) Where factored pulse is required upon mechanical temp.compensation (T + PGS EP) Where factored pulse is required upon mechanical temp.compensation (T + PG) Where factored pulse is required upon mechanical temp.compensation (T + PGEP) Where factored pulse is required upon mechanical temp.compensation (T + PGD) Where factored pulse is required upon mechanical temp.compensation (T + PGDEP) Others ccuracy (Linearity): ±.%
When making inquiries, Please state following information : Please fill out the following specifications when making inquiries.. Model L. Fluid to be measured Name Viscosity mpa s Specific gravity. (m /h) Maximum Normal Minimum. Fluid temperature ( ) Maximum Normal Minimum. mbient temperature ( ) Maximum Normal Minimum. Pressure (MPa) Maximum Normal Minimum. Flow direction Right Left, Bottom Top 8. Flange connection Nominal diameter mm, Flange rating. Required accuracy (Linearity) ± %. Explosion-proof construction Required class Not required. ccessories Strainer, ir eliminator, ompanion flange. Quantity Including accessories. Receiving device Type, manufacturer, model, specifications (input, output, power supply, etc.). Distance between the flow meter and the receiving device m Remote Instrumentation Signal type and application (totalizer, indicator, recorder, controller, computer input, data logger input, batch, blend) Pulse generator type and signal unit Full scale and unit Flowmeter to receiving instrument distance Power source, voltage, frequency Receiving instrument utomatic Batching Quantity per batch, preset full scale Time required for each batch Daily total number of batch llowable error in each batch Operating air pressure, power source, voltage, frequency Valve used and accessories The specification as of Sep., is stated in this GS Sheet. Specifications and design are subject to change without notice. Sales Representative: