C101-E112. BioSpec-nano. Shimadzu Spectrophotometer for Life Science

Similar documents
Spectrophotometer for Life Science. BioSpec-nano C101-E112D

Structural Analysis by In-Depth Impurity Search Using MetID Solution and High Accuracy MS/MS

Operation Manual. SPECTRO-NANO4 Nucleic Acid Analyzer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

TL6 Ultra Micro-volume Spectrophotometer

BioDrop DUO dsdna Application Note

The Plus for your lab!

INSTRUCTION MANUAL. VWR myspec spectrophotometer

JAPAN QUALITY. Automated Clinical Analyzer

Nano Spectrophotometer LNS-A10

ON SITE SYSTEMS Chemical Safety Assistant

SolidSpec-3700 SolidSpec-3700DUV

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

ND-1000 Spectrophotometer. V3.5 User s Manual

Micro-Spectrohpotometer USERS MANUAL

Jasco V-670 absorption spectrometer

CHEMISTRY WORKSTATION. The power of proven quality GIVING YOU PEACE OF MIND

ND-1000 Spectrophotometer. V3.3 User s Manual

In Association With. Introduces. TPT Contractor

JAPAN QUALITY. Automated Clinical Analyzer

C101-E111. Talk Letter. Vol.2 February 2009

ISSP User Guide CY3207ISSP. Revision C


A new chapter. medicacorp.com

SOFTWARE USER MANUAL. Weather Capture Advance WS1640 WM9280

Software BioScout-Calibrator June 2013

CLINICAL CHEMISTRY ANALYSER. The economical solution for all your needs GIVING YOU PEACE OF MIND

NINE CHOICE SERIAL REACTION TIME TASK

Protein Sequencer PPSQ-31A / 33A C297-E055B

C101-E116. Talk Letter. Vol.4 March 2010

Nucleic Acid Thermo Scientific NanoDrop Spectrophotometers

Biochrom Libra. UV-Visible Spectrophotometers. High performance instruments with added application value for academia, research and industry

Quick Start Guide New Mountain Visit our Website to Register Your Copy (weatherview32.com)

1/5 Specifications Hidex 300 SLL automatic TDCR liquid scintillation counter

Single Nano Particle Size Analyzer

TitriSoft 2.5. Content

Spectrometer User s Guide

FLASH CHROMATOGRAPHY

Automated Clinical Analyzer

SPECTROPHOTOMETERS. Visible and UV-Visible

Manual Laser Doppler Anemometry Manual remote experiment Project e-xperimenteren+

Microplate Spectrophotometer

NEW HOLLAND IH AUSTRALIA. Machinery Market Information and Forecasting Portal *** Dealer User Guide Released August 2013 ***

Protein Deconvolution Version 2.0

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Zetasizer Nano-ZS User Instructions

Experiment 13. Dilutions and Data Handling in a Spreadsheet rev 1/2013

AutoChem II 2920 A Catalyst Characterization Laboratory

M E R C E R W I N WA L K T H R O U G H

Reference Manual. Program Help for Electrophoretic Buffer Studies. Version 1.3. Copyright 2001 ANALIS sa/nv

Optical density measurements automatically corrected to a 1-cm pathlength with PathCheck Technology

mylab: Chemical Safety Module Last Updated: January 19, 2018

An ultra-sensitive, versatile, and affordable single tube luminometer for Life Science Research.

Minimum (-31) every 10 s -35 (-31)

Nucleic Acid Quantitation in Microplates

World s First Universal Quantum Computation Simulator. Quantum Computer Simulator. For Windows/Macintosh. User Guide

96 Well? Done! Eppendorf epmotion 96 semi-automated electronic pipette for fast and precise 96 channel microplate processing

Ocean Optics Educational Spectrometers. Getting Started Manual

PolarSync Quick Start

NanoPhotometer NP80/N60/N50/C40 User Manual. Version 1.0.5

Instruction Manual. Qubit Fluorometer. probes.invitrogen.com/qubit

How to Make Photometric & Colorimetric Measurements of Light Sources using an Ocean Optics Spectrometer and SpectraSuite Software


FoodScreen Radiological Food Screening System

Colorimetric Protein Assays Thermo Scientific NanoDrop Spectrophotometers

3M Microbiology. 3M TM Petrifilm TM Plate Reader

C101-E100. Talk Letter. Vol.1 October 2008

User's Guide. DISTO online. Leica Geosystems

Fast, Effective XPS Point Analysis of Metal Components

Photoluminescence Spectrometer (FLS980)

HSC Chemistry 7.0 User's Guide

ISIS/Draw "Quick Start"

Quality Measures Green Light Report Online Management Tool. Self Guided Tutorial

PowerWaveX Select and KC4 : A Multifunctional System for Today s Laboratory Environment

Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI

Lightcloud Application

A Program for the Study of Driven Piles under Axial Loads

Presenting Tree Inventory. Tomislav Sapic GIS Technologist Faculty of Natural Resources Management Lakehead University


University of Colorado Denver Anschutz Medical Campus Online Chemical Inventory System User s Manual

Dielectric Analysis of Insulation Liquids

Orbit Support Pack for Excel. user manual

The Multi-Wiper HE. High Energy Nuclear Medicine Well Counter. The first multi-well counters designed specifically for Nuclear Medicine!

Ramberg-Osgood Convertor. User Manual

Nanoparticle Analyzer

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

ST-Links. SpatialKit. Version 3.0.x. For ArcMap. ArcMap Extension for Directly Connecting to Spatial Databases. ST-Links Corporation.

SC400 Colorimeter. Silica. Photometer-System. Instruction Manual. SiO 2. Bedienungsanleitung Seite Instruction Manual Page 19 33

Measurement of L-Malic Acid in Wines Using the SpectraMax Plus 384 Microplate Reader

SuperCELL Data Programmer and ACTiSys IR Programmer User s Guide

Protocol for Use of BCMP Jasco J-815 Circular Dichroism Spectropolarimeter

CyFlow Ploidy Analyser & CyFlow Space High-resolution DNA analysis

FleXScan User Guide. for version 3.1. Kunihiko Takahashi Tetsuji Yokoyama Toshiro Tango. National Institute of Public Health

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

LED Lighting Facts: Product Submission Guide

L-malic acid measurement in wines using the SpectraMax Plus 384 Microplate Reader

SSL promotion activities 1. Seminars. 2. User Meeting. 3. Academic Conferences. 4. Internal Sales Training

A Program for the Study of Driven Piles under Axial Loads

In-System Serial Programming (ISSP) Guide

BioSpec-mini. Shimadzu Nucleic Acid & Protein Spectrophotometer

User's Manual. Chemical software Acid-base equilibria for Windows. ABEW Version Windows XP - Windows Vista - Windows 7 - Windows 8 - Windows 10

Transcription:

C101-E112 BioSpec-nano Shimadzu Spectrophotometer for Life Science

Power of small. BioSpec-nano

BioSpec-nano Shimadzu Spectrophotometer for Life Science Quick and Simple Nucleic Acid Quantitation Drop-and-Click Analysis To analyze a sample, just drop it onto the target and click the button. The instrument will perform measurement and wiping automatically. 1 μl or 2 μl Nucleic Acid Quantitation Analysis can be performed with 1 μl (pathlength: 0.2 mm) or 2 μl (pathlength: 0.7 mm) samples. Quick & Simple Operation Blank measurement, sample measurement, output of reports as PDF or CSV files, and other basic operations are performed quickly and simply just by a click of a button. Contents P 4.5 - Drop-and-Click Analysis P 6.7 - Quick & Simple Operation P 8 - Stress-free Nucleic Acid & Labeled Nucleic Acid Quantitation P 9 - Outstanding Analysis Range & Measurement Reproducibility P 10 - BioSpec-nano Specifications P 11 - Introducing a "Power of Small Series" Product

Drop-and-Click Analysis [1 μl / 2 μl samples can be meas Just drop the sample onto the target and click the button. That's all there is to analysis. The instrument will perform everything else for you sample mounting, measurement and wiping. Liquid-contact parts no longer need to be wiped with a cloth. 1. Drop the sample. Sample volume required for measurements are *: 1 μl for pathlength 0.2 mm 2 μl for pathlength 0.7 mm 2. Start measurement. Click the button with the mouse to start sample measurement. You will find using the [start] button on the instrument handy when performing analyses with gloves on. Button in software window Just click the button. And leave the rest up to the instrumen Instrument [start] button 3. Check the analysis results. Analysis results are automatically displayed after measurement ends. A series of samples can be analyzed while confirming spectra in the Detailed View Mode. [Simple Nucleic Acid Quant. - Detailed View Mode] [Measurement Sample: Purified dsdna in Tris-EDTA (TE) buffer] * If the surface tension of the sample is small, droplets might not be formed with a 1 to 2 μl sample. 4

ured.] Automatic Mounting and Wiping Function (1) Automatic Mounting The upper window automatically moves down, and a droplet with the specified pathlength is formed. Upper window Target (2) Measurement The Xenon flash lamp is lit for 3 seconds to perform spectrum measurement. t! (3) Automatic Wiping After measurement, liquid-contact parts (upper window and target) are automatically cleaned by the dedicated wiper. The utility life of the dedicated wiper is about 100 operations.* The wiper features excellent water absorption and there is little influence from contamination. * We recommend exchanging the wiper after each series of sample measurements or once per day. Position of wiper arm during wiping 5

Quick & Simple Operation Basic operations can be conveniently performed by clicking icons in the software or function keys on the instrument itself. Start Starts sample measurement. Exchange Wiper Moves the wiper arm to the exchange position so a new wiper can be attached. The wiping count is reset at each exchange of the wiper. Blank Executes blank measurement. [Simple Nucleic Acid Quant. - Detailed View Mode] [Measurement Sample: Purified dsdna in TE buffer] 6

Detail / List Toggles between the Detail and List view modes. Detail Displays the analysis results and spectrum of the sample currently selected. List Displays the analysis results of all samples in a table format. Check Marks analysis results of interest for review. [Simple Nucleic Acid Quant. - List View Mode] Exit Exits the software. Analysis results are automatically saved. Display PDF Converts analysis results to PDFs and displays them in Adobe Reader. [PDF Display Output Example] Save CSV/PDF Saves analysis results to CSV or PDF files. CSV files can be edited in Microsoft Excel or other spreadsheet software. CSV File Output Example 7

Stress-free Nucleic Acid & Labeled Nucleic Acid Quantitation Simple Nucleic Acid Quantitation Mode For the quantitation of RNA, dsdna, ssdna, and OligoDNA. The nucleic acid concentration and OD ratio (OD260/280 and OD260/230) are calculated. [Simple Nucleic Acid Quant. - Detailed View Mode] [Measurement sample: Purified dsdna in TE buffer] [Analysis Setting Windows - Simple Nucleic Acid Quant.] Labeled Nucleic Acid Quantitation Mode For the quantitation of nucleic acids (RNA, dsdna, ssdna, OligoDNA) labeled by Cy3, etc. The nucleic acid concentration, label concentration, nucleotide concentration, and labeling ratio are all calculated. [Labeled Nucleic Acid Quant. - Detailed View Mode] [Measurement Sample: OligoDNA labeled by Cy3 in TE buffer] [Analysis Setting Windows - Labeled Nucleic Acid Quantitation] 8

Outstanding Analysis Range & Measurement Reproducibility Secure Analysis / High Measurement Accuracy The optimum pathlength for the sample concentration can be selected using the instrument lever. * Laptop PC is sold separately. Pathlength: 0.2 mm Example of analysis at 1 μl* Pathlength: 0.7 mm Example of analysis at 2 μl* Pathlength: 5 mm The 5 mm pathlength cell and 5 mm cell adapter are required separately. The optional 5 mm pathlength cell and its adapter are placed over the target for use as shown below. Example of analysis at 2 ml* 5 mm pathlength cell (sample volume: 2 ml) (P/N: 208-92258) 5 mm cell adapter (P/N: 206-26513) * All of the analysis example data are provided for reference only. 1 OD corresponds to 50 ng/μl dsdna. Sample: Purified dsdna Buffer: TE Ten measurements were performed at each point. 9

BioSpec-nano Specifications Hardware Specifications Item Measuring wavelength range Spectrum band width Wavelength accuracy Pathlength Photometric range Photometric value unit Option cell Sample volume Light source Monochrometer Specification 220 to 800 nm 3 nm ±1 nm 0.2 mm, 0.7 mm (manual selection) 0 to 1.5 Abs OD (Optical Density), absorbance converted with 10 mm pathlength Available (pathlength: 5 mm, sample volume: 2 ml) Pathlength lever switched to Option (5 mm) position 1 μl min. (pathlength: 0.2 mm) 2 μl min. (pathlength: 0.7 mm) Xenon flash lamp Holographic grating Item Detector Auto wiping function Sample mount function Spectrum measuring time Quantitation range (OD, dsdna concentration) Power requirements Ambient temperature, humidity Dimensions Weight Specification Photo diode array Provided Auto 3 sec Pathlength 0.2 mm, 1 to 75 OD 50 to 3,700 ng / μl Pathlength 0.7 mm, 0.3 to 21 OD 15 to 1,000 ng / μl Optional 5 mm pathlength cell, 0.04 to 3 OD 2 to 150 ng / μl AC 100 V / 120 V / 220 V / 230 V / 240 V, 50 / 60 Hz, 40 VA 18 to 28 C, 40 to 80 % (without dew condensation) Width 210 mm x Depth 214 mm x Height 417 mm 7 kg Software Specifications Item Analysis mode Simple nucleic acid quantitation Labeled nucleic acid quantitation Label management Analysis results display Specification Simple nucleic acid quantitation, labeled nucleic acid quantitation Nucleic acid concentration (RNA, dsdna, ssdna, OligoDNA) calculation OD ratio (OD260 / 280, OD260 / 230) calculation Nucleic acid concentration (RNA, dsdna, ssdna, OligoDNA), nucleotide concentration calculation Label concentration, labeling ratio calculation OD ratio (OD260 / 280) calculation Label registration (up to 8 new labels), edit, deletion Default labels (Cy 3, Cy 5, Alexa Fluor 546, Alexa Fluor 647) Detailed view (displays the focused sample analysis results and spectrum) List view (displays analysis results of all samples) Item Analysis data judgement PDF output CSV output User management (Multiple user mode) Specification OD ratio (OD260 / 280, OD260 / 230), OD 800 judgement Analysis results (detailed view, list view) saved in PDF file Analysis results (detailed view, list view), spectra data saved in tab delimited text Multiple user or single user mode selected at the time of installation User management: User registeration, edit, deletion Login: User name, password entry Data saved in respective folders PC Requirements for BioSpec-nano Item OS CPU System memory Hard disk capacity Display resolution USB2.0 port Printer Disk drive * A separate PC is required. Specification Windows Vista Business SP1 Windows XP Professional SP2/SP3 1.6 GHz or higher processor 512 MB or larger (1 GB or larger when using Windows Vista) 40 GB or larger 1024 x 768 pixels or above 1 port or more (for connecting the instrument), 2 ports or more when using a USB printer Printer compatible with the system used DVD-ROM or CD-ROM drive H : 417mm Consumables P/N 206-25901 Part Name Wiping paper (highly absorbent wiper, 100 sheets/set) W : 210mm D : 214mm BioSpec, MultiNA, and Power of small are trademarks or registered trademarks of Shimadzu Corporation. Microsoft, Windows, Windows Vista, Windows XP, and Excel are trademarks or registered trademarks of Microsoft Corporation in the United States or other countries. Adobe, Adobe logo, Acrobat, Adobe PDF logo, Distiller and Reader are trademarks or registered trademarks of Adobe Systems Incorporated in the United States or other countries. Cy is a registered trademark of GE Healthcare. Alexa Fluor is a trademark or registered trademark of Invitrogen. 10

Small, but powerful. Small, and easy to use. Shimadzu's superb range of laboratory tools embraces the power of small. JQA-0376 Founded in 1875, Shimadzu Corporation, a leader in the development of advanced technologies, has a distinguished history of innovation built on the foundation of contributing to society through science and technology. We maintain a global network of sales, service, technical support and applications centers on six continents, and have established long-term relationships with a host of highly trained distributors located in over 100 countries. For information about Shimadzu, and to contact your local office, please visit our Web site at www.shimadzu.com SHIMADZU CORPORATION. International Marketing Division 3. Kanda-Nishikicho 1-chome, Chiyoda-ku, Tokyo 101-8448, Japan Phone: 81(3)3219-5641 Fax. 81(3)3219-5710 URL http://www.shimadzu.com The contents of this brochure are subject to change without notice. Printed in Japan 3295-01908-50AIT