A New Low Background Laboratory in the Pyhäsalmi Mine: Towards 14C free liquid scintillator for low energy neutrino experiments

Similar documents
Underground Physics in the Pyhäsalmi mine

arxiv: v1 [physics.ins-det] 3 Feb 2011

Neutron flux measurement using fast-neutron activation of 12 B and 12 N isotopes in hydrocarbonate scintillators

Rivelazione di neutrini solari - Borexino Lino Miramonti 6 Giugno 2006 Gran Sasso

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

1. Introduction on Astroparticle Physics Research options

The JUNO veto detector system. Haoqi Lu Institute of High Energy physics (On Behalf of the JUNO Collaboration) TIPP2017, May22-26,Beijing

XMASS: a large single-phase liquid-xenon detector

Overview about the Work with Liquid Scintillators

Neutrino Physics with SNO+ Freija Descamps for the SNO+ collaboration

Study of Performance Improvement for Air Shower Array with Surface Water Cherenkov Detectors

arxiv: v1 [physics.ins-det] 22 Dec 2016

Muon detector and muon flux measurement at Yangyang underground laboratory for the COSINE-100 experiment

Hands on Project: Large Photocathode PMT Characterization

Neutrino oscillations from CERN to Pyhäsalmi

The LENA Neutrino Observatory

Primary cosmic ray mass composition above 1 PeV as measured by the PRISMA-YBJ array

arxiv: v2 [nucl-ex] 24 Jul 2015

Publications of Francesco Arneodo: journal articles

Characteristics of Forbush decreases measured by means of the new scintillation muon hodoscope ScMH

PoS(EPS-HEP2017)074. Darkside Status and Prospects. Charles Jeff Martoff Temple University

Astroparticle physics

Dark matter search with the SABRE experiment

arxiv: v1 [physics.ins-det] 27 Jun 2017

LENA. Investigation of Optical Scintillation Properties and the Detection of Supernovae Relic Neutrinos. M. Wurm. January 18, 2006 LENA. M.

LOW ENERGY SOLAR NEUTRINOS WITH BOREXINO. Lea Di Noto on behalf of the Borexino collaboration

Neutrino Oscillations

Measurement of 39 Ar in Underground Argon for Dark Matter Experiments

The NEXT-100 experiment for Neutrino-less Double Beta decay: Main features, Results from Prototypes and Radiopurity issues.

PoS(ICHEP2016)474. SoLid: Search for Oscillations with a Lithium-6 Detector at the SCK CEN BR2 reactor

Neutrino oscillation physics potential of Hyper-Kamiokande

The next generation dark matter hunter: XENON1T status and perspective

The Short Baseline Neutrino Program at Fermilab

Studies of the XENON100 Electromagnetic Background

Search for Dark Matter with Liquid Argon and Pulse Shape Discrimination

GERDA: The GERmanium Detector Array for the search for neutrinoless decays of 76 Ge. Allen Caldwell Max-Planck-Institut für Physik

Radioactivity measurements for the ERMES project at the STELLA facility

POTASSIUM GEONEUTRINOS AND THEIR DETECTION

Recent results from the UK Dark Matter Search at Boulby Mine.

The SOX experiment. Stefano Davini (on behalf of the Borexino-SOX collaboration) Brussels, December 1 st 2017

Timing calibration of the LHAASO-KM2A electromagnetic particle detectors

Astroparticle physics

XMASS 1.5, the next step of the XMASS experiment

A Large Liquid Scintillator Detector for Neutrino Mass Hierarchy : RENO-50

A multipurpose detector for low energy

HEROICA: a test facility for the characterization of BEGe detectors for the GERDA experiment

Testing DAMA/LIBRA signal with ANAIS-112

PoS(EPS-HEP2017)008. Status of the KM3NeT/ARCA telescope

The GERmanium Detector Array

Neutrino Experiments: Lecture 2 M. Shaevitz Columbia University

Neutrino AstroPhysics

Calibration of large water-cherenkov Detector at the Sierra Negra site of LAGO

The NUCLEON Space Experiment Preliminary Results. Skobeltsyn Institute of Nuclear Physics, Moscow State University, Moscow, , Russia

arxiv:hep-ex/ v1 15 Aug 2006

Underground cosmic-ray experiment EMMA

PANDA-X A New Detector for Dark Matter Search. Karl Giboni Shanghai Jiao Tong University

arxiv: v1 [physics.ins-det] 27 Feb 2014

Neutrinoless double beta decay with SNO+

Barometric pumping effect for radon-due neutron flux in underground laboratories

ANAIS: Status and prospects

Results on geoneutrinos at Borexino experiment. Heavy Quarks and Leptons Yamagata Davide Basilico

Hands on LUNA: Detector Simulations with Geant4

Distillation purification and radon assay of liquid xenon

Neutrino Geophysics at Baksan I: Possible Detection of Georeactor Antineutrinos

Background optimization for a new spherical gas detector for very light WIMP detection

Accurate Measurement of the Cosmic Ray Proton Spectrum from 100TeV to 10PeV with LHAASO

Neutrino Physics. Neutron Detector in the Aberdeen Tunnel Underground Laboratory. The Daya Bay Experiment. Significance of θ 13

Observation of Reactor Antineutrinos at RENO. Soo-Bong Kim for the RENO Collaboration KNRC, Seoul National University March 29, 2012

KamLAND. Introduction Data Analysis First Results Implications Future

Complex set of cosmic rays monitoring

PoS(ICRC2017)945. In-ice self-veto techniques for IceCube-Gen2. The IceCube-Gen2 Collaboration

Scintillator phase of the SNO+ experiment

The Cosmic Ray Air Fluorescence Fresnel lens Telescope (CRAFFT) for the next generation UHECR observatory

Antifreeze design for Muon Detector of LHAASO

Neutrino detectors. V. Lozza,

Underground Physics in Pyhäsalmi Mine

An Underground Laboratory for a Multi-Detector Experiment. Karsten Heeger Lawrence Berkeley National Laboratory

PoS(idm2008)010. The PICASSO Dark Matter Search Project. A. Davour for the PICASSO collaboration Queen s University

Water Purification in Borexino

Jelena Maricic Drexel University. For Double Chooz Collaboration. Spain. France. Germany U.S.A. Japan Russia. Brazil U.K. Courtesy of T.

Neutrinos. Why measure them? Why are they difficult to observe?

Metallicities in stars - what solar neutrinos can do

XENONNT AND BEYOND. Hardy Simgen. WIN 2015 MPIK Heidelberg. Max-Planck-Institut für Kernphysik Heidelberg

DarkSide-50: performance and results from the first atmospheric argon run

The DarkSide-50 Outer Detectors

Solar Neutrinos in Large Liquid Scintillator Detectors

1. Neutrino Oscillations

Detectors for astroparticle physics

Radioactivity and Ionizing Radiation

Status and Perspectives for KM3NeT/ORCA

Neutrino Experiments with Reactors

arxiv:physics/ v1 3 Aug 2006

Determination of parameters of cascade showers in the water calorimeter using 3D-distribution of Cherenkov light

GERDA experiment A search for neutrinoless double beta decay. Roberto Santorelli (Physik-Institut der Universität Zürich)

UNIT1: Experimental Evidences of Neutrino Oscillation Atmospheric and Solar Neutrinos

Neutrinoless Double Beta Decay Search with SNO+

Borexino and status of the project Aldo Ianni INFN, Gran Sasso Laboratory on behalf of the Borexino collaboration

Measurements of Liquid Scintillator Light Yield for Future Neutrino Experiments

Supernova Neutrinos in Future Liquid-Scintillator Detectors

LENA Scintillator Development

Transcription:

A New Low Background Laboratory in the Pyhäsalmi Mine: Towards 14C free liquid scintillator for low energy neutrino experiments S. Lubsandorzhiev* 2, T. Enqvist 1, J. Hissa 1, J. Joutsenvaara 1, J. Kutuniva 1, P. Kuusiniemi 1, A. Virkajärvi 1, L. Bezrukov 2, V. Kazalov 2, S. Krokhaleva 2, B. Lubsandorzhiev 2, A. Sidorenkov 2, K. Loo 3, M. Słupecki 3, W. Trzaska 3, 1 Oulu Southern Institute and Astronomy Research Unit, University of Oulu, Finland; 2 Institute for Nuclear Research of the Russian Academy of Sciences, Moscow, Russia; 3 Department of Physics, University of Jyväskylä, Finland E-mail:sultim@inbox.ru A new low background laboratory in Pyhäsalmi mine in the Central Finland has been put into operation in the beginning of 2017. The laboratory operates at the depth of 1436 m (~4100 meters of water equivalent). In this paper, we present description of the laboratory s existing facility and background conditions. In the laboratory, a series of measurements has been started where the 14 C concentration is determined from several liquid scintillator samples. A dedicated setup has been designed and constructed with the aim of measuring the 14 C/ 12 C ratio smaller than 10-18. 35th International Cosmic Ray Conference ICRC2017 *Speaker 10-20 July, 2017 Bexco, Busan, Korea Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (CC BY-NC-ND 4.0).

1. Introduction The Pyhäsalmi mine is located in the Central Finland. The maximum depth of the mine is ~1440 m corresponding to ~4100 meters of water equivalent (m.w.e.). There is well developed infrastructure in and around the mine. High quality high ways and railroads connect the site with international airports in Helsinki and Oulu. The geographical location and transverse section of the mine are shown in Fig. 1a and b respectively. It takes half an hour to reach the deepest point from the surface by ven very heavy trucks using 11 km long decline or just 3 minutes by a hoist capable transporting ~21 tons of ore or 20 persons. At the deepest point there is also high quality communication system (fiber optics, mobile phone network). The foregoing put the mine into excellent position to host large-scale astroparticle experiments. Indeed, the site has been under intense discussions connected with a number of astroparticle physics experiments- LAGUNA long base line experiment and LENA multi-purpose low energy neutrino project. a) b) Figure 1. Pyhasalmi mine a) geographical location; b) transverse section/ Presently a collaboration of several Finnish and Russian universities and institutions are running the EMMA experiment [1, 2], which is located in the mine at relatively shallow depth of 85 m (~240 m.w.e.). The experiment measures muon multiplicities of extensive air showers trying to study mass composition of primary cosmic rays around the knee region (~5 10 15 ev). 2

2. Facility of a new low background laboratory in the Pyhasalmi mine. In parallel to the EMMA experiment several years ago, we started to develop a low background laboratory in the big cavity at the depth of 1436 m (~4100 m.w.e.). The laboratory is provided with air ventilation, electricity and connected with the surface laboratory via optical fibre. A photograph of the new low background laboratory is shown in Fig. 2. Figure 2. Pyhasalmi mine The radon content in the laboratory is at the level of less than 20 Bq/m 3. Radioactive background of surrounding rock is the following: 238 U (7.8±0.3) 10-8 g/g 232 Th (7.6±1.5) 10-8 g/g 40 K (1.69±0.02) 10-7 g/g The rock activity measurements were done at the Baksan low background laboratory. The depth intensity curve measured at different depths in the mine is presented in Fig. 3 [3]. The muon flux at the depth of 1390 m, slightly above the low background laboratory is F = (1.1 0.1) 10-4 m -2 s -1 [3]. The new laboratory operation started with measurements of concentration of 14 C isotope in liquid scintillators. 3

Figure 3. Depth-intensity curve measured in the Pyhasalmi mine [3] 3. Measurements of 14 C/ 12 C ratio in liquid scintillators The intrinsic 14 C content in liquid solvents is the main source of background at very low energies in high-purity liquid scintillation detectors. 14 C concentration values measured in a number of liquid organic solvents are presented in Tab. 1 for scintillators based on PC (Pseudocumene; C9H12), PXE (Phenylxylylethane; C16H18) and Dodecane (C12H26). So far there are no published data for the 14 C concentration measurements in LAB (Linear alkylbenzene; C6H5CnH2n+1, n=10 16) which is presently the most actively used solvent for liquid scintillator being under development for large-scale detectors of low energy neutrinos like SNO+ and JUNO. Table 1 C concentration ( 10-18 ) Liquid scintillator & Experiment Reference fluor 1.94 0.09 PC+PPO Borexino CTF 4 9.1 0.4 PXE+p-Tp+ -MSB Borexino CTF 5 3.98 0.94 PC-Dodecane+PPO KamLAND 6 12.6 0.4 PXE+PPO Dedicated setup 7 The end-point energy (Q ) of the 14 C -decay spectrum is relatively low, Q =156 kev. Therefore, the detector counting rate due to 14 C -decay could be simply lowered by setting the 4

appropriate threshold energy. Nevertheless, unfortunately, too high concentration of 14 C in the liquid scintillator may results in the effect of pile-ups of pulses. For instance, in the Borexino detector at Gran Sasso, Italy, the trigger rate is largely dominated by the 14 C isotope [8] (with the 14 C/ 12 C ratio of ~2 10-18 ). Based on the analysis of the 14 C/ 12 C ratio in liquid scintillators produced using derivatives from old deep oil and gas fields [9], it is believed that values of 14 C content lower than 10-18 should be achievable if the source is carefully chosen. The contamination from the reaction 14 N(n; p) 14 C is expected to be the main source of 14 C also deep underground but in this case neutron flux is produced by U and Th decay chains. A dedicated campaign has been started to measure the 14 C concentration in several liquid scintillator samples (based on oil, gas and coal derivatives of different locations) with the goal to find samples with 14 С concentrations smaller than 10-18. Careful measurements of 14 С concentrations are presently ongoing simultaneously with essentially similar set-ups and rock overburden, in two deep underground laboratories: in the Baksan Neutrino Observatory, Russia [10] and in the new low background laboratory in the Pyhäsalmi Mine [11]. The Accelerator Mass Spectroscopy (AMS) method [12] is capable to measure isotopes concentrations at the level of 10-15. To study the 14 C concentration in liquid scintillators at the level lower than 10-15 a dedicated experimental set-up has been developed, Fig. 4a. The central part of the detector set-up of the present work consists of two low background PMTs (3" ET 9302B), Fig. 4c, two acrylic light guides and a quartz vessel of 1.6 litres, Fig. 4c. The vessel and light guides are wrapped by VM2000 high reflective foil. a) b) c) Figure 4. A dedicated set-up for measurements of 14C concentration in the Pyhäsalmi mine. The shielding against and neutron background is implemented using thick layers (10 15 cm) of copper and lead around the central part. Paraffin layer (approximately 10 cm, as the outer 5

layer) may also be used to thermalize neutrons from the surrounding rock. The central part of the set-up is flushed with nitrogen to reduce the background from radon. The DAQ is developed using the DRS4 evaluation board (V5) [13] which is based on the DRS4 Switched Capacitor Array chip designed at the Paul Scherrer Institute, Villigen, Switzerland. Output signals of the two PMTs are fed directly to the inputs of the DRS4 board, which is connected to the DAQ Laptop via an USB connector. The DRS4 digitizes the pulse waveform in 10-bits range with 0.2 ns step and with the maximum sampling rate of 5 GS/s. Two channel high voltage power supply module NHQ 203M HV produced by iseg, Germany, is used to power the PMTs. The PMTs radioactive background levels were measured also at the Baksan low background laboratory and their values are the following: 238 U 220 mbq/pmt 232 Th 24 mbq/pmt 40 K 400 mbq/pmt Solvents of the liquid scintillator samples are purified by standard means using Al 2 O 3 column and they are mixed with ~3 g/l of PPO and bubbled with nitrogen to remove oxygen. The purification process is currently performed at the room atmosphere. A special purification system where the full process could be performed in a nitrogen atmosphere is presently under development. The energy calibration of the whole set-up is carried out using a number of -ray radioactive sources and finding the position of their Compton edges or the full absorption peak at low energies (~100 kev). 57 Co, 109 Cd, 133 Ba, 137 Cs and 241 Am sources are currently used in calibration measurements. Figure 5. Shielding of the set-up for measurements of 14C concentration. The calibration of 3-inch ET9302B photomultiplier tubes has been carried out in the laboratory with a fast blue LED light source. In the data processing, the digitized waveforms of the PMT signals are analyzed and the signal waveforms are used to suppress -particles and neutron 6

induced backgrounds. Measurements of 14 C content in different samples of liquid scintillators are being intensely done and as long as there are no final experimental results available yet from the new low background laboratory in the Pyhäsalmi mine. 4. Conclusion The new low background laboratory in Pyhäsalmi mine in the Central Finland started to operate. The laboratory is located at the depth of 1436 m (~4100 meters of water equivalent). In the laboratory, a series of measurements began to study 14 C concentration in a number of liquid scintillators produced by several manufacturers and from different oil and coal derivatives. A dedicated setup has been developed and built with the aim of measuring the 14 C/ 12 C ratio smaller than 10-18. The laboratory s deep location, low radioactivity background of surrounding rock and very good infrastructure allows to hope that the laboratory will start to attract many large-scale astroparticle physics experiments. This work was supported by the Russian Foundation for Basic Research, grant #16-52-53120. References [1] E.A. Akhrameev et al. Nuclear Instruments and Methods A. 2009. V.610. P.419 [2] V.I. Volchenko et al., Central European Physics Journal. 2010. V.8. N.3. P.425 [3] T. Enqvist et al. Measurements of muon fluxin the Pyhäsalmi underground laboratory. Nuclear Instruments and Methods A. 2005. V.554. P.286. [4] G. Alimonti et al. Physical Letters B. 1989. 442. P.49. [5] H.O. Back et al. Nuclear Instruments and Methods A. 2008. V.584. P.48. [6] G. Keefer. arxiv:1102.23876. [phys. ins-det] 18 February 2011. [7] C. Buck et al. Instruments and Experimantal Techniques. 2012. V.55. P.34. [8] G. Bellini et al. Phys. Rev. D. 2014. V.89. P.112007 [9] G. Bonvicini et al. arxiv:hep-ex/0308025v2 8Aug 2003. [10] Yu. Gavrilyuk et al. Nuclear Instruments and Methods A. 2013. V.729. P.576. [11] P. Jalas et al. Proceedings of Neutrino 2016 conference. London 2016. [12] S.M. Fahmi et al. Nuclear Instruments and Methods A. 2013. V.294. P.302. [13] http://www.psi.ch/drs/documentation 7