Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS

Similar documents
Hints and Tips for APGC Coupled with Xevo TQ-S for Food and Environmental Analysis

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

DETERMINATION OF OCs, PCBs AND SYNTHETIC PYRETHROIDS IN ANIMAL FAT

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Investigating Source, Age, Maturity, and Alteration Characteristics of Oil Reservoirs Using APGC/MS/MS Analysis of Petroleum Biomarkers

Highly Sensitive and Rugged GC/MS/MS Tool

A Case of Pesticide Poisoning: The Use of a Broad-Scope Tof Screening Approach in Wildlife Protection

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEY WORDS. Simultaneous high-throughput screening of melamine (MEL) and cyanuric acid (CYA).

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

A Method for Simultaneous Analysis of 174 Pesticides in Grape Using GC-MS/MS

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

LC-HRMS: Challenges for Routine Implementation

[application note] INTRODUCTION EXPERIMENTAL. Specimens. Extraction

Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry

Simultaneous determination of 74 kinds of pesticides in Chinese herbal medicine listed in Chinese pharmacopoeia (2015) by GPC-GC-MS/MS

Determination of Pesticide Residues in Oats by Automated. QuEChERS and LC/QQQ. Application Note. Abstract. Introduction

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Multi-residue analysis of pesticides by GC-HRMS

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

A S ENSIT IV E M E T HO D FO R T H E D E T E RM INAT IO N O F ENDO C RIN E- D IS RU P T ING COM P OUNDS IN RIV E R WAT E R BY L C / MS/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

DETERMINATION OF PESTICIDES IN FOOD USING UPLC WITH POLARITY SWITCHING TANDEM QUADRUPOLE LC/MS/MS

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

Analysis of Pesticides in Baby Foods Using a Triple-Quadrupole GC/MS/MS

Analysis of pesticide residues using various GC/MS systems. Radim Štěpán Czech Agriculture and Food Inspection Authority Prague, Czech Republic

Analysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Definitive EtG/EtS LC-MS/MS Analysis:

Food & Environmental. Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou SCIEX, Concord, Ontario, Canada

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Validation Report 18

Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate Yu 3

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis

T H E ANA LYSIS O F DIOX INS AND F U R A NS USING H RG C- H IG H R E SO LU T IO N MS W IT H T H E AU T OS P EC- ULTIMA NT

USP Method Transfer and Routine Use Analysis of Irbesartan Tablets from HPLC to UPLC

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

Validation Report 8 Determination of pesticide residues in rice and wheat by GC-MS/MS and LC-MS/MS (QuEChERS method) Appendix 2

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

Overview. Introduction

Pesticides Analysis Using the Agilent 5977A Series GC/MSD

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

Metabolic Phenotyping Using Atmospheric Pressure Gas Chromatography-MS

Q-TOF PREMIER DYNAMIC RANGE ENHANCEMENT AND ACCURATE MASS MEASUREMENT PERFORMANCE

Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou AB SCIEX, Concord, Ontario, Canada

C HA R AC T E RIZ AT IO N O F INK J E T P RINT E R C A RT RIDG E INK S USING A CHEMOMETRIC APPROACH

The Use of Tandem Quadrupole GC/MS/MS for the Determination of Polycyclic Aromatics Hydrocarbons (PAHs) in Food Products

Validation Report Determination of isoprothiolane residues in rice by GC-MS/MS (QuEChERS method)

Traditional Herbal Medicine Structural Elucidation using SYNAPT HDMS

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

ApplicationNOTE A STUDY OF THE ANALYSIS OF POLYBROMINATED DIPHENYL ETHER FLAME RETARDANTS BY GC/MS/MS. Introduction. Materials and Methods

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

2010 Waters Corporation. Xevo TQ-S for Bioanalysis

Solvent Flexibility for Size-Based Polymer Analysis Using the Advanced Polymer Chromatography (APC) System

Fully automated QuEChERS clean-up and LC/MS-QQQ analysis of pesticides in fruits and vegetables.

Routine MS Detection for USP Chromatographic Methods

Multi-residue analysis of pesticides in crude food extracts using a simple extraction technique and LC/MS/MS

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

László Tölgyesi LC/MS scientist EFSC Demo Group. International Symposium on Food Safety and Quality: Applications of Nuclear and Related Techniques

The Quantitation and Identification of Coccidiostats in Food by LC-MS/MS using the AB SCIEX 4000 Q TRAP System

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

Tyler Trent, Applications Sales Specialist, Teledyne Tekmar P a g e 1

DEMONSTRATING SUPERIOR LINEARITY: THE ACQUITY UPLC PHOTODIODE ARRAY DETECTOR

[application note] ACQUITY UPLC/SQD ANALYSIS OF POLYMER ADDITIVES. Peter J. Lee, and Alice J. Di Gioia, Waters Corporation, Milford, MA, U.S.A.

Analysis of Labeled and Non-Labeled Proteomic Data Using Progenesis QI for Proteomics

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

Analysis of Pesticides in Citrus Oil Using a Shimadzu GCMS-TQ8030. No. GCMS No. SSI-GCMS-1404

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

High Efficiency, Broad Scope Screening of Pesticides Using Gas Chromatography High Resolution Orbitrap Mass Spectrometry

[ a ppl ic at ion no t e ]

A Newly Approved ASTM Standard For Analysis of Thiophene in Benzene Using a Pulsed Flame Photometric Detector (PFPD)

Organochlorine Pesticides by GCxGC-ECD

ApplicationNOTE THE ANALYSIS OF POLYCHLORINATED BIPHENYLS (PCBS) BY GC-HIGH RESOLUTION MASS SPECTROMETRY USING THE MICROMASS AUTOSPEC ULTIMA NT

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Method of determination of phtalates in spirituous beverages by gaschromatography/mass

Performing Peptide Bioanalysis Using High Resolution Mass Spectrometry with Target Enhancement MRM Acquisition

[ FOOD SAFETY SOLUTIONS ] FASTER, EASIER, AND MORE ACCURATE FOOD SAFETY ANALYSES

Determination of Chlorinated Acid Herbicides in Soil by LC/MS/MS Application Note

UPLC Intact MASS Analysis Application Kit

Identification of Human Hemoglobin Protein Variants Using Electrospray Ionization-Electron Transfer Dissociation Mass Spectrometry

Determination of Pharmaceuticals in Environmental Samples

Application Note. Abstract. Introduction. Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution

Agilent 6495 Triple Quadrupole LC/MS System EXPERIENCE A NEW LEVEL OF CONFIDENCE

Implementation of Methods Translation between Liquid Chromatography Instrumentation

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Routine Multiresidue Pesticide Analysis using the Agilent 6470 Triple Quadrupole Mass Spectrometer

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

ImprovIng ADmE ScrEEnIng productivity In Drug DIScovEry

Jane Cooper 1 and Jérémy Marchand 2. Waters Corporation, Manchester, UK; 2 University of Nantes, France APPLICATION BENEFITS INTRODUCTION

Transcription:

Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS Dominic Roberts, 1 Sara Stead, 1 and Jennifer A. Burgess 2 1 Waters Corporation, Manchester, UK 2 Waters Corporation, Milford, MA, USA APPLICATION BENEFITS Increased sensitivity and selectivity for GC amenable pesticides Analyze LC and GC compounds on a single MS platform Fast and easy processing of MS data using TargetLynx WATERS SOLUTIONS DisQuE QuEChERS CEN Method Sample Preparation Kit, Pouches Atmospheric Pressure Gas Chromatography (APGC) INTRODUCTION Pesticides are widely used in the production of fruit and vegetables across the globe. Their use is widespread and governments, food producers and food retailers have a duty to ensure they are not present in final products for consumption. Most countries have clearly defined regulations governing pesticide residues. Legislation imposes Maximum Residue Limits (MRLs) for pesticides in food products requiring analytical techniques that are sensitive, accurate and robust. Multi-residue pesticide analysis is challenging due to the low limits of detection required in a diverse range of food commodities. As there are currently in excess of 00 pesticides in use, laboratories are under increasing pressure to broaden the range of pesticides determined in ever shorter turnaround times. Therefore, the analytical methods they employ need to be sensitive and robust in a wide variety of sample matrices. Typically, this analysis is carried out using a dedicated GC-MS/MS system using an EI source. As shown by Portolēs et al, 1 this source causes extensive fragmentation of some analytes leading to low sensitivity of the molecular ion. APGC is a soft ionization technique which results in an increased abundance of the parent ion and therefore enhancing sensitivity and specificity. An additional advantage is that the APGC source is interchangeable with the ESI source enabling a single MS platform to be used for the analysis of both LC and GC amenable pesticides. In this application note, we demonstrate that the Waters Xevo TQ-S equipped with an APGC source provides a sensitive and repeatable solution for the analysis of pesticides in QuEChERS extracts of strawberry, pear, and spinach. Xevo TQ-S TargetLynx Application Manager KEY WORDS Pesticides, fruit, vegetable, QuEChERS, Atmospheric Pressure Gas Chromatography, MS/MS 1

E X P E R IM E N TA L GC conditions GC system: 7890A GC Column: DB5-MS m x 0.25 mm x 0.25 µm film Carrier gas: He 1.2 ml/min Temp. gradient: Initial 70 C for 0.1 minute, 33 C/min to 180 hold for 1 min, 7 C/min to 0 C, hold 6.52 min Total run time: min Injector temp.: 250 C Injection type: Pulsed split/splitless Pulse time: 1 min Pulse pressure: 55 psi Injection volume: 1 µl Makeup gas: N 2 at 0 ml/min Transfer line temp.: 3 C MS conditions MS system: Xevo TQ-S Mode: API + Corona : 2.0 µa Cone gas: 0 L/hr Aux gas: 250 L/hr Source temp.: 150 C GC-MS/MS cone and collision parameters and MRM transitions used for this study are presented in Table 1. Sample preparation QuEChERS is a simple sample preparation technique suitable for multi-residue pesticide analysis in a variety of food and agricultural products. Strawberry, pear, and spinach samples were homogenized using a domestic food blender. The samples were then extracted using the DisQUE QuEChERS (CEN method 15662) protocol to generate blank matrix extract in acetonitrile. A nine-point calibration range from 0 to 50 ng/ml (equivalent to µg/kg) was prepared by adding a mixed pesticide standard in acetonitrile to each matrix. To test the repeatability at low concentration, each matrix was fortified with the pesticide mix at 1 µg/kg. A deuterated internal standard, chrysene -d12, was added to provide a fixed concentration of 2 ng/ml to each vial prior to analysis and this was used as an injection standard to correct for injection volume variation. All standards were analyzed in triplicate and the low level spike in each matrix was analyzed times using the Waters Xevo TQ-S with APGC source. Two MRM transitions were monitored for each pesticide, the most abundant species for quantification and the less abundant species for confirmation. MRMs were developed by injection of the solvent standards using a fast GC method ( minute gradient). The first step was to identify the precursor ion, which was followed by further injections to identify optimal product ions. The final step was to optimize the cone voltages and collision energies so that sensitive and specific MRMs were added to the instrumental method. RESULTS AND DISCUSSION The GC amenable pesticides that are difficult to analyze using an EI source due to excessive fragmentation, in strawberry, pear, and spinach was achieved using APGC with the Xevo TQ-S operated in target MRM mode. The MRMs with optimized cone voltages and collision energies are shown in Table 1. Using APGC and by varying the source conditions, analysts can choose to promote either proton transfer or charge transfer as the major ionization process. For the analysis of pesticides the dominant ionization mechanism was [M+H] +. Therefore, a vial of water was added to the source to promote protonation. The high intensity of the parent molecular ion observed in APGC spectra makes it possible to generate specific and sensitive MRM transitions for the target analytes. In contrast, many pesticide MRMs using an EI source rely on using a lower m/z, less specific fragment ion as the precursor. These features of APGC ensure that the analyst has confidence in identifying and quantifying pesticides that are detected in fruit and vegetable samples. 2

Each sample type, including matrix matched standards and replicates was analyzed on three different days. Figure 1 shows a typical calibration curve and residuals plot for endosulphan sulphate generated from the triplicate injection of each matrix-matched calibration standard in strawberry extract. The response was linear from 0.05 to 50 ng/ml with a correlation coefficient R 2 of 0.994. All of the residuals were <15% demonstrating excellent linearity and repeatability of the APGC system. The limits of detection and linearity achieved for all pesticides using the APGC with the Xevo TQ-S System are summarized in Table 1. The limits of detection ranged from 0.01 to 0.5 ng/ml with excellent linearity (R 2 >0.99) for all pesticides. This demonstrates that the method can easily achieve the regulatory limits and is applicable to routine quantitative analysis. Figure 1. Calibration and residuals plot of the pesticide endosulphan sulphate in strawberry matrix constructed using triplicate injections of each calibration point. 3

Compound Retention time (min) Aldrin 13.4 Azinphos-Ethyl 14.2 Azinphos-Methyl.0 Buprofezin 15.9 Chlorfenvinphos 14.3 Chlorpyriphos 13.2 Chlorpyriphos-Methyl 12.1 Dichlorvos 6.3 Dicrotophos 9.6 Dieldrin 16.0 Endosulfan I 15.3 Endosulfan-Ether 18.7 Endosulfan-Sulphate 17.7 Endrin 16.5 Ethion 16.8 Fenarimol.7 Heptachlor Epox B 17.7 Mevinphos 7.5 Phenthoate 14.4 Phosphamidon 12.0 MRM Cone voltage Collision energy 363>159 363>215 289>261 289>233 261>125 261>167 6>6 0>3 359>170 359>5 350>198 350>294 322>125 322>212 221>145 221>127 238>112 238>193 379>325 379>261 5>323 5>217 341>5 341>217 323>217 323>287 379>243 379>343 385>143 385>125 331>139 331>268 387>217 387>252 225>127 225>193 321>135 9 321>163 12 0>127 0>227 Limit of (ng/ml) Corelation coeffect (R 2 ) 0.50 0.992 0.50 0.990 0.05 0.994 0. 0.995 0.01 0.990 0. 0.995 0. 0.990 0.01 0.995 0.05 0.997 0. 0.997 0. 0.990 0. 0.993 Table 1. Summary of the pesticides analyzed, MRMs monitored, and quantitative performance results. 4

To assess the accuracy and precision of the method each sample matrix was spiked at 1 µg/kg ( times below the blanket MRL of µg/kg) and replicate injections were made. The concentration of each pesticide was calculated using matrix-matched calibration graphs. Figure 2 shows the mean calculated concentrations for each pesticide in all three sample matrices. The accuracy of the method is excellent, with all of the pesticides within 5% of the true concentration. Table 2 shows the mean concentrations for each pesticide in each of the three matrices. The %RSD for all pesticides is also shown to be very good at <5%. This demonstrates that the method is both accurate and reproducible across different sample matrices analyzed on different days. The sensitivity and performance of APGC with Xevo TQ-S currently exceeds existing regulations related to pesticide residue analysis. This additional sensitivity enables samples to be diluted, thereby reducing matrix interferences and minimizing the amount injected on column. This is turn has major benefits for system cleanliness and reduces the frequency of instrument maintenance requirements. Mean calculated concentration spike at 1 µg/kg (n=) in three different matrices Mean calculated concentration µg/kg Figure 2. Bar chart showing the mean concentration of pesticides spiked at 1 µg/kg in three different matrices (n=). 5

Spiked samples at 1 µg/kg Mean calculated concentration (n=) Pesticide Strawberry Pear Spinach Aldrin 0.99 1.01 0.90 Azinphos-Ethyl 1.03 0.94 0.94 Azinphos-Methyl 0.94 0.93 1.02 Buprofezin 0.98 0.97 0.96 Chlorfenvinphos 0.97 1.01 0.93 Chlorpyriphos 1.02 1.01 0.96 Chlorpyriphos-Methyl 1.01 1.01 0.95 Dichlorvos 1.04 1.00 0.87 Dicrotophos 0.99 0.99 1.00 Dieldrin 0.97 1.01 0.99 Endosulfan-Ether 0.99 1.01 0.90 Endosulfan-Sulphate 0.99 0.99 0.91 Endrin 1.02 1.02 0.95 Ethion 0.99 1.05 0.93 Fenarimol 1.00 1.04 0.95 Heptachlor Epox B 1. 1.00 0.93 Mevinphos 1.14 0.98 0.92 Phenthoate 1.01 1.02 0.93 Phosphamidon 1.04 1.04 0.90 Mean 1.01 1.00 0.94 SD 0.045 0.031 0.038 %RSD 4 3 4 Table 2. The mean concentration of each pesticide (n=) in the three sample matrices. RSD(%) <5. 6

CONCLUSIONS The ability to analyze both LC and GC compounds on a single MS platform is a significant advantage when trying to analyze an increasing number of compounds in a wide variety of sample matrices. References 1. T Portoles, L Cherta, J Beltran, F Hernandez, J Chromatogr A. 1260 (12) 183. APGC is a soft ionization technique that produces abundant [M+H] + ions for the majority of pesticides, which makes it possible to generate selective and sensitive MRM transitions that EI-GC-MS/MS systems fail to achieve routinely. APGC in combination with the Xevo TQ-S has been shown to be sensitive, accurate, and reproducible for pesticides that are difficult to analyze by conventional EI-GC-MS/MS. APGC offers the performance and versatility required for routine quantitative, multi-residue pesticide analysis in QuEChERS extracts of fruit and vegetables. Waters, Xevo, and The Science of What s Possible are registered trademarks of Waters Corporation. DisQuE and TargetLynx are trademarks of Waters Corporation. All other trademarks are the property of their respective owners. 14 Waters Corporation. Produced in the U.S.A. March 14 7004984EN AG-PDF Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 1 508 478 00 F: 1 508 872 1990 www.waters.com