Intro to Sample Prep:

Similar documents
Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Basics in Solid Phase Extraction (SPE)

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

Chemical Analysis Problem

SPE. Simply Efficient! Watchers bond Solid Phase Extraction by ISU. Ver

[ Care and Use Manual ]

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - CHROMABOND. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - SOLA & HyperSep. Catalogue 9.

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Sample Prep Options for GC users

Solid Phase Micro Extraction (SPME) of Opiates from Urine: Coupling SPME and DESI-MS/MS Detection

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods

What type of samples are common? Time spent on different operations during LC analyses. Number of samples? Aims. Sources of error. Sample preparation

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples

Chromatography. Gas Chromatography

METHOD 3600B CLEANUP

Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)

The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Solid Phase Extraction Method Development Tips and Tricks

A New Polymer-based SPE Sorbent to Reduce Matrix Effects in Bioanalytical LC-MS/MS

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Automated Sample Preparation. Andrew Duggan, PhD Aman Sharma Shimadzu Scientific Australia

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Open Column Chromatography, GC, TLC, and HPLC

Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications

METHOD 3600C CLEANUP

Simplify Sample Preparation [ SAMPLE PREPARATION SOLUTIONS ]

Yuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB

Determination of Pesticide Residues in Oats by Automated. QuEChERS and LC/QQQ. Application Note. Abstract. Introduction

CHROMATOGRAPHY. The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments.

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Chapter content. Reference

Thermo Scientific HyperSep Dispersive SPE Products. Efficient sample preparation and clean-up using the QuEChERS Method

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

GC/MS Application Note

trust Sample Preparation Products

SUPELCO. SPME-Adsorption versus Absorption: Which Fiber is Best for Your Application? Robert E. Shirey and Raymond F. Mindrup

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Thermo Scientific Chromatography Columns and Consumables. Trusted solutions. uncompromised analysis

OPTIMISATION OF SOLID PHASE MICROEXTRACTION (SPME) CONDITIONS FOR HEADSPACE ANALYSIS OF ORGANOPHOSPHATE PESTICIDES IN WHOLE BLOOD

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Development for SPE. Ron Majors Senior Chemist, CSD Joan Stevens SPE Application Chemist October 2009

Katherine K. Stenerson, Michael Ye, Michael Halpenny, Olga Shimelis, and Leonard M. Sidisky. Supelco, Div. of Sigma-Aldrich Bellefonte, PA USA

PAL SPME Arrow The Better SPME

BEKOlut - YOUR PARTNER FOR SMART SPE SOLUTIONS

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

Carbon Molecular Sieves and Spherical Graphitized Polymer Carbons for Sample Preparation Processes and Bulk Scale Purification Processes

Evaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis

Solid Phase Microextraction

PAL SPME Arrow The Better SPME

Headspace Technology for GC and GC/MS: Features, benefits & applications

Application Note. Abstract. Introduction. Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Analysis of Phthalates in Body Wash using Solid-Supported Liquid-Liquid Extraction

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

High Performance Liquid Chromatography

Application of Bio-SPME for the Enrichment of Illicit Phenethylamine and Cathinone Compounds from Biological Samples

Characterization of Carbon SPE for the Extraction of Polar Analytes

Biochemistry. Biochemical Techniques HPLC

Packings for HPLC. Packings for HPLC

High Performance Liquid Chromatography

Shodex TM ODP2 HP series columns

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Sample Preparation. Approaches to Automation for SPE

Agilent Products for Solid Phase Extraction. Improve the quality of your sample preparation so you can improve the quality of your analysis.

Bulletin 910. Guide to Solid Phase Extraction. Introduction 1

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Welchrom TM Solid Phase Extraction (SPE) Products From Welch Materials, Inc.

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

Preparation. Sample. Solid Phase Extraction (SPE) Discovery Products SUPELCO

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

ChromTech options for PAL systems

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

anthracene Figure 1: Structures of Selected Polyaromatic Hydrocarbons (PAHs)

CHAPTER CHROMATOGRAPHIC METHODS OF SEPARATIONS

SPE Columns. Solid Phase Extraction. SPE Columns

Determination of Alkaloids in Goldenseal Using Agilent Bond Elut Plexa Solid Phase Extraction Sorbent for Cleanup and HPLC-DAD Analysis

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

AN INTEGRATED SYSTEM USING TEMPERATURE BASED SAMPLING FOR POLYMER CHARACTERIZATION

Liquid Chromatography

Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

ProPac WCX-10 Columns

Determination of trace anions in concentrated hydrofluoric acid

Chemistry Instrumental Analysis Lecture 28. Chem 4631

Quad-Z 215 with Disposable Tips: Implementing the Use of ZipTips for the Purification of Biological Samples

Inside the Black Box of an Environmental Testing Laboratory Basic Analytical Procedures

Development of analytical methods for Catecholamines, Metanephrines and related metabolites in urine and plasma matrices

Sample Preparation Products General Catalogue. Sample Preparation Products General Catalogue

high performance OPTIC 3 and applications a total analytical solution

THE USE OF ORGANOCLAY IN MANAGING DISSOLVED ORGANIC CONTAMINANTS RELEVANT TO CONTAMINATED SEDIMENTS

Physical Separations and Chromatography

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

SPEReference Manual & Users Guide

Transcription:

Intro to Sample Prep: SPE and SPME Irina Galushko, irina.galushko@merckgroup.com

Why Sample Prep?..but the same technology workflow for analysis May require a unique sample prep solution 2

3 Time Spent on the Analytical Process

Sample prep Sources of Chromatographic Errors Contaminiation 4% Sample introduction 6% Interation 6% Chromatography 7% Sample Preparation 30% Instrument 8% Calibration 9% Column 11% Operator 19% Source: LC/GC Magazin 2002 4

SPE Solid Phase Extraction

Real World & Real Samples The Importance of Sample Preparation Urine Sample without SPE Urine Sample with SPE 0 2 4 6 Time (min) 0 2 4 6 Time (min)

Why is sample preparation required? Collected Sample GC, HPLC, or LC-MS/MS Analysis X Current Sample = Unsuitable for further analysis!!! Why? Too dirty- contains other sample matrix components that interfere with the analysis Too dilute- analyte(s) not concentrated enough for quantitative detection Present sample matrix not compatible with or harmful to the chromatographic column/system

SPE Formats Sorbent particles held securely in place to withstand the force of the liquid flow. 96-well plates Disks Tubes Loose/bulk sorbent (QuEChERS) Online SPE 8

On the Inside: SPE Sorbents (Packing Materials) The sorbent is the component of the tube responsible for the extraction. Most SPE sorbents are also used in HPLC applications, although with large particles in SPE. Some of the most common are: Silica-based Reversed phase (C18, C8, cyano, phenyl) Normal phase (silica, diol, NH 2 ) Ion exchange (SAX, WCX, SCX) Carbon-based Polymer-based Various compositions Different functionalities Others Florisil (magnesium silicate) Alumina Mixed-bed Combinations of nearly any of the above are possible in sequential layers Supel Sphere dual-layer 9

SPE Strategies There are 2 different elution strategies in SPE. Which one to choose depends on the goal of the extraction. 1. Bind-Elute Strategy Most common Bind: Analytes bind to tube, unwanted matrix components are washed off Elute: Eluant changed to remove analytes from tube Different eluents can be used to fractionate the analytes Analytes are concentrated via evaporation prior to HPLC or GC analysis Sorbent types employing this: DSC-C18, Supel -Select HLB, SupelMIP, ENVI -Carb Plus, PS/DVB, DSC-MCAX, ENVI -Chrom P 2. Interference Removal Strategy Bind all unwanted matrix components and allow analytes to pass through during the sample loading stage Like chemical filtration Sorbent types employing this: HybridSPE, QuEChERS, PSA, ENVI -Carb, Dual Layer 10

Bind-Elute Strategy Must first condition & equilibrate SPE tube Bind-Elute sorbent types: DSC-C18, Supel -Select HLB, SupelMIP, ENVI - Carb Plus, PS/DVB, DSC- MCAX, ENVI -Chrom P 11

Interference Removal Strategy Chemical Filtration Sample with Internal Standard in Matrix Matrix adsorbed Analytes & IS pass Must first condition & equilibrate SPE tube Interference Removal sorbent types: HybridSPE, QuEChERS, PSA, ENVI -Carb, Dual Layer 12

Well-Established SPE Product Lines Discovery Pharmaceutical focus Tube and 96-well plates Supelclean TM ENVI Environmental focus ENVI -Carb is a key product Supel TM -Select Polymeric, Universal SPE ENVI -DSK TM disks Porous glass fiber membranes embedded with sorbent particles 13

Sample Prep Star Products Overcoated SPME Physically robust fiber for direct immersion that is less prone to chemical fouling. Supel QuE QuEChERS tubes and supplies Pesticide Residue, PAH, PCB, PDBE analysis Supelclean Ultra Dual layer cartridge for the cleanup of difficult matrices such as dry commodities (tea, spices, coffee, etc.) Supel Tox Removes interferences associated with mycotoxin analysis Supel MIP Molecularly imprinted polymers Highly selective for analytes in difficult matrices Supelclean EZ-POP NP Simple, effective extraction of lipophilic persistent organic pollutants (POPs) from oily samples Supel -Select Polymeric SPE 14

Supel-Select: What is Hydrophilic Polymer SPE? Polymer chromatographic media designed for SPE Comprises of a hydrophilic component and a hydrophobic component: Hydrophilic component examples: N-vinyl pyrilidone, methacrylate, hydroxyl, vinylamidizol Hydrophobic component examples: Polystyrene, divinyl benzene

Supel-Select HLB: Statins from Rat Plasma Total Ion Chromatogram (MRM, 4 pairs: 557.3/397.2) Rat Plasma spiked with 5 ng/ml Statins

Supel-Select HLB: Minimum Extractables Assays today require greater sensitivity SPE phase chemistry and hardware should impart minimum extractables Each lot is tested for: Recovery LC-UV & LC-MS cleanliness Particle size Density Pore size Pore volume

Supel-Select Polymeric SPE Why are they so popular in SPE? Water Wettable do not dry out => highly reproducible Amenable to generic methodology Often referred to as a universal SPE phase Can retain an extremely broad range of compounds (polar to non-polar; acidic basic) Retained compounds easily eluted/ desorbed with MeOH or similar solvent Reduces ion suppression in LC/MS Low UV and MS extractables 1000s of references using this technology KZQ www.sigmaaldrich.com/supel-select

Current Supelclean Ultra 2400 Cartridge Cleanup difficult matrices prior to pesticide residue analysis by GC/MS/MS and LC/MS/MS Dry commodities (tea, spices, coffee, etc.), typically highly concentrated and with higher background than fresh samples Pigments and oils Not sufficiently cleaned by QuEChERS Dual layer SPE cartridge (1 ml and 3 ml) containing PSA, C18, specialty carbon, and Z-Sep Specialized Carbon reduces pigmentation and allows for recovery of planar pesticides without toluene Z-Sep sorbent Removes oils and some pigments, as was indicated in the cleanup of turmeric extracts for both GC and HPLC analysis 19 sigma-aldrich.com/supelcleanultra

SupelMIP SPE Molecularly Imprinted Polymer SPE MIPs (molecularly imprinted polymers) are SPE products designed for the highly selective extraction of trace analytes from complex matrices Selective Interaction Superior selectivity => reduced ion-suppression => achieve lower detection limits Robust & rapid methodology => Save time, money, & headache No method development req d sigma-aldrich.com/supelmip

Supelclean EZ-POP NP: For the extraction of non-polar compounds from edible oils Florisil layer Preferentially retains fatty matrix interferences Non-polar compounds are washed through and then analyzed Compared to other SPE methods: Produces a cleaner extract Z-Sep/C18 layer Easier and more versatile methodology The final extracts are in acetonitrile Compatible with both GC and HPLC. 21 sigma-aldrich.com/ez-pop

SPME Solid Phase Microextraction

Solid Phase Microextraction (SPME) Economical enrichment technique mainly for trace analysis Semivolatiles & volatile (GC) Coated fused silica or metal fibers (adsorbent/particle & absorbent/film coatings) Initially for GC analysis, now extended to LC Features: Very limited or no use of solvents All types of samples & matrixes Direct immersion or headspace Designs for manual, auto samplers and robots Benefits: One-step extraction that is easy to automate Quantitative and reproducible Extractions Portable (field use) and reusable 23 SigmaAldrich.com/spme

Official Methods / Applications applying SPME Europe ISO 27108 (former DIN 38407-34/Germany) Determination of selected plant treatment agents and biocide products - Method using solid-phase microextraction (SPME) followed by gas chromatographymass spectrometry (GC-MS) (Based on DIN 38407-F 34 from Germany) ISO 17943 (former DIN 38407-41/Germany) German standard methods for the examination of water, waste water and sludge - Jointly determinable substances (group F) - Part 41: Determination of selected easily volatile organic compounds in water - Method using gas chromatography (GC-MS) after solid-phase micro extraction (SPME) (F 41) OENORM A 1117, 2004-05-01 Determination of volatile compounds in cellulose-based materials by Solid Phase Micro Extraction (SPME) UNICIM 2237 / 2009 - Italian Method on SPME for air sampling Determinazione Delle Aldeidi Aerodisperse Methodo per microestrazione su fase solida (SPME) ed analisi mediante gascromatografia accoppiata a spettrometria di massa (GC-MS) Determination of air borne aldehydes by SPME/GC-MS using derivatisation on fiber with PFBHA 24

Other official methods for SPME US Methods ASTM D 6438, 2005 Standard Test Method for Acetone, Methyl Acetate, and Parachlorobenzotrifluoride Content of Paints, and Coatings by Solid Phase Microextraction-Gas Chromatography ASTM D 6520, 2000 Standard Practice for the Solid Phase Micro Extraction (SPME) of Water and its Headspace for the Analysis of Volatile and Semi-Volatile Organic Compounds ASTM D 6889, 2003 Standard Practice for Fast Screening for Volatile Organic Compounds in Water Using Solid Phase Microextraction (SPME) ASTM E 2154, 2001 Standard Practice for Separation and Concentration of Ignitable Liquid Residues from Fire Debris Samples by Passive Headspace Concentration with Solid Phase Microextraction (SPME) EPA Method 8272 (Dec 2007) Parent and Alkyl Polycyclic Aromatics in Sediment Pore Water by SPME GC/MS

How SPME is used 1 Analyst has a sample they want to determine the content of If sample prep is required 2 They extract the compounds from the sample onto the SPME fiber 3 They desorb the fiber into the GC instrument which tells them what was in the sample GC chromatogram showing all the compounds that were extracted from the sample by the SPME fiber

The SPME Concept 27 After extraction typically direct injection into GC injector port for thermal desorption

Sampling Technique: Headspace vs. Direct Immersion Analytical considerations: Volatility of sample Extraction time concerns Sample matrix Selectivity of analytes Direct immersion extraction Headspace extraction Liquid sample Liquid or solid sample 28

Adsorption Mechanism for SPME SPME is quantitative!!! Silica Rod Analyte Adsorbed Liquid Polymer Aqueous Solution Vial Time 29

SPME Fiber Coating: The Business End An equilibrium is set up between analytes dissolved in the sample (solution or gas phase) and in the liquid coating on the fiber. The fiber coating consists of: GC-type phases Particles Enlargement of the SPME fiber coating 30

Types of SPME Fiber Coatings Films Absorption: Coating Type Polarity 7 µm Polydimethylsiloxane (PDMS) Absorbent Nonpolar 30 µm PDMS Absorbent Nonpolar 100 µm PDMS Absorbent Nonpolar 85 µm Polyacrylate (PA) Absorbent Polar 60 µm PEG (Carbowax) Absorbent Polar Particles Adsorption: Coating Type Polarity 85 µm Carboxen-PDMS Adsorbent Bipolar 65 µm PDMS-DVB Adsorbent Bipolar 55 µm/30 µm DVB/Carboxen-PDMS Adsorbent Bipolar 31

Molecular Weight Range for SPME Fibers Carboxen DVB-Carboxen DVB 100µm PDMS 30µm PDMS 7µm PDMS 0 150 300 450 Molecular Weight Range 32

Effects of Salt and ph Salt usually increases analyte uptake Use 25-30% NaCl to salt-out samples Not necessary for large non-polar analytes, such as PAHs and large hydrocarbons, and may reduce recovery Lower ph to extract acidic compounds Raise ph to extract basic compounds Beware of stability of analytes at different ph levels 33

Thank You For Your Kind Attention! Copyright 2017 EMD Millipore Corporation. All Rights Reserved. MilliporeSigma, Millipore and the vibrant M are trademarks of Merck KGaA, Darmstadt, Germany. Supel, Supelclean, ENVI-Carb, and Stableflex are trademarks and Discovery, SLB, and SupelMIP are registered trademarks of Sigma-Aldrich Co. LLC. FocusLiner is a trademark of SGE Analytical Science Pty Ltd. Florisil is a registered trademark of U.S. Silica Company. Agilent is a registered trademark of Agilent Technologies, Inc. The life science business of Merck KGaA, Darmstadt, Germany operates as MilliporeSigma in the U.S. and Canada. 34