Study of a new concept of photovoltaic-thermal hybrid collector

Similar documents
Exergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness

NUMERICAL HEAT TRANSFER ENHANCEMENT IN SQUARE DUCT WITH INTERNAL RIB

Performance Assessment of PV/T Air Collector by Using CFD

Chapter 3 NATURAL CONVECTION

Solar Flat Plate Thermal Collector

UNIT FOUR SOLAR COLLECTORS

Experiment 1. Measurement of Thermal Conductivity of a Metal (Brass) Bar

Autumn 2005 THERMODYNAMICS. Time: 3 Hours

Numerical Study of Convective Heat Transfer for Flat Unglazed Transpired Solar Collectors

Numerical Study of the Three-dimensional Flow in a Flat Plate Solar Collector with Baffles

Comparative study of Different Geometry of Ribs for roughness on absorber plate of Solar Air Heater -A Review

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 06, 2015 ISSN (online):

Ceiling Radiant Cooling Panels Employing Heat-Conducting Rails: Deriving the Governing Heat Transfer Equations

CHME 302 CHEMICAL ENGINEERING LABOATORY-I EXPERIMENT 302-V FREE AND FORCED CONVECTION

True/False. Circle the correct answer. (1pt each, 7pts total) 3. Radiation doesn t occur in materials that are transparent such as gases.

Examination Heat Transfer

Keywords: Spiral plate heat exchanger, Heat transfer, Nusselt number

COVENANT UNIVERSITY NIGERIA TUTORIAL KIT OMEGA SEMESTER PROGRAMME: MECHANICAL ENGINEERING

EXPERIMENTAL AND NUMERICAL STUDIES OF A SPIRAL PLATE HEAT EXCHANGER

Effects of Nanofluids Thermo-Physical Properties on the Heat Transfer and 1 st law of Thermodynamic in a Serpentine PVT System

The Electrodynamics of a Pair of PV Modules with Connected Building Resistance

MAXIMUM NET POWER OUTPUT FROM AN INTEGRATED DESIGN OF A SMALL-SCALE OPEN AND DIRECT SOLAR THERMAL BRAYTON CYCLE. Willem Gabriel le Roux

Ben Wolfe 11/3/14. Figure 1: Theoretical diagram showing the each step of heat loss.

Experimental Evaluation of Natural Heat Transfer in Façade Integrated Triangular Enclosures

International Journal of Scientific & Engineering Research, Volume 6, Issue 5, May ISSN

EFFECT OF STAGGERED RIB LENGTH ON PERFORMANCE OF SOLAR AIR HEATER USING V-RIB WITH SYMMETRICAL GAP AND STAGGERED RIB

Convection Heat Transfer. Introduction

ENHANCEMENT OF THE HEAT TRANSFER RATE IN FREE CONVECTION SOLAR AIR HEATER USING PIN SHAPED ARTIFICIAL ROUGHNESS ON ABSORBER PLATE

Heat and Mass Transfer Unit-1 Conduction

PLATE TYPE HEAT EXCHANGER. To determine the overall heat transfer coefficient in a plate type heat exchanger at different hot fluid flow rate

Heat Transfer Enhancement of Solar Air Heater By Using Artificial Roughness double inclined ribs

HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF COMPOUND TURBULATORS IN RECTANGULAR DUCTS OF SOLAR AIR HEATER

Introduction to Heat and Mass Transfer. Week 5

W-Discrete Rib for Enhancing the Thermal Performance of Solar Air Heater

Thermal Analysis of a Flat-Plate Solar Collectors in Parallel and Series Connections Huseyin Gunerhan

EFFECT OF BAFFLES GEOMETRY ON HEAT TRANSFER ENHANCEMENT INSIDE CORRUGATED DUCT

Simplified Collector Performance Model

HEAT LOSS CHARACTERISTICS OF A ROOF INTEGRATED SOLAR MICRO-CONCENTRATING COLLECTOR

1D and 3D Simulation. C. Hochenauer

Faculty of Technology and Science Department of Physics and Electrical Engineering. Helena Johansson. Nocturnal cooling

Circle one: School of Mechanical Engineering Purdue University ME315 Heat and Mass Transfer. Exam #2. April 3, 2014

Effect of V-Shape Twisted Jaw Turbulators on Thermal Performance of Tube heat exchanger: An Experimental Study

Simulation of Free Convection with Conjugate Heat Transfer

ME 331 Homework Assignment #6

International Journal of Advanced Engineering Technology E-ISSN

COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF A V-RIB WITH GAP ROUGHENED SOLAR AIR HEATER

A concrete heat accumulator for use in solar heating systems a mathematical model and experimental verification

Numerical Investigation on Turbulent Forced Convection in Heating Channel Inserted with Discrete V-Shaped Baffles

Introduction to Heat and Mass Transfer. Week 14

Computational Fluid Dynamics Based Analysis of Angled Rib Roughened Solar Air Heater Duct

Department of Mechanical Engineering ME 96. Free and Forced Convection Experiment. Revised: 25 April Introduction

Chapter 5 MATHEMATICAL MODELING OF THE EVACATED SOLAR COLLECTOR. 5.1 Thermal Model of Solar Collector System

Examination Heat Transfer

CFD Analysis of Forced Convection Flow and Heat Transfer in Semi-Circular Cross-Sectioned Micro-Channel

Numerical Investigation of The Convective Heat Transfer Enhancement in Coiled Tubes

PROBLEM 7.2 1/3. (b) The local convection coefficient, Eq. 7.23, and heat flux at x = L are 1/2 1/3

Optimization of the Air Gap Spacing In a Solar Water Heater with Double Glass Cover

Parametric Effect on Performance Enhancement of Offset Finned Absorber Solar Air Heater

Analysis of the Cooling Design in Electrical Transformer

Convection Workshop. Academic Resource Center

طراحی مبدل های حرارتی مهدي کریمی ترم بهار HEAT TRANSFER CALCULATIONS

Thermo-Fluid Dynamics of Flue Gas in Heat Accumulation Stoves: Study Cases

1 Conduction Heat Transfer

S.E. (Chemical) (Second Semester) EXAMINATION, 2011 HEAT TRANSFER (2008 PATTERN) Time : Three Hours Maximum Marks : 100

Tutorial 1. Where Nu=(hl/k); Reynolds number Re=(Vlρ/µ) and Prandtl number Pr=(µCp/k)

Heat Transfer Convection

INTERNATIONAL JOURNAL OF SCIENTIFIC & TECHNOLOGY RESEARCH VOLUME 5, ISSUE 09, SEPTEMBER 2016 ISSN

Study of Temperature Distribution Along the Fin Length

Thermal Unit Operation (ChEg3113)

PHYSICAL MECHANISM OF CONVECTION

Heat Transfer Enhancement of Solar Flat Plate Collector by Using V Corrugated Fins and Various Parameters

FORMULA SHEET. General formulas:

Empirical Co - Relations approach for solving problems of convection 10:06:43

EXPERIMENTAL AND THEORETICAL ANALYSIS OF TRIPLE CONCENTRIC TUBE HEAT EXCHANGER

Coolant. Circuits Chip

TankExampleNov2016. Table of contents. Layout

Heat Transfer Analysis of Machine Tool Main Spindle

PROBLEM Node 5: ( ) ( ) ( ) ( )

HEAT TRANSFER ENHANCEMENT OF SOLAR FLAT PLATE COLLECTOR BY USING V CORRUGATED FINS AND VARIOUS PARAMETERS

Thermo-Hydraulic Performance of a Roughened Square Duct Having Inclined Ribs with a Gap on Two Opposite Walls

External Forced Convection :

Performance Investigation of Artificially Roughened Duct used in Solar Air Heaters

Modelling Results of Covered PVT Collectors regarding Low-E Coatings and F

TOPIC 2 [A] STEADY STATE HEAT CONDUCTION

1 Conduction Heat Transfer

Effect of External Recycle on the Performance in Parallel-Flow Rectangular Heat-Exchangers

Lecture 28. Key words: Heat transfer, conduction, convection, radiation, furnace, heat transfer coefficient

A dynamic model of hybrid photovoltaic/thermal panel

Dynamic thermal simulation of a solar chimney with PV modules

Numerical Analysis of a Helical Coiled Heat Exchanger using CFD

DETAILED MODELING OF SOLAR FLAT-PLATE COLLECTORS WITH DESIGN TOOL KOLEKTOR 2.2

Estimation of Heat Transfer in Internally Micro Finned Tube

The influence of PV coverage ratio on thermal and electrical performance of photovoltaic-trombe wall

Performance of contact and non-contact type hybrid photovoltaic-thermal (PV-T) collectors

1. Nusselt number and Biot number are computed in a similar manner (=hd/k). What are the differences between them? When and why are each of them used?

Lecture 30 Review of Fluid Flow and Heat Transfer

EFFECT OF OPERATING PARAMETERS ON THE PERFORMANCE OF THE HYBRID SOLAR PVT COLLECTOR UNDER DIFFERENT WEATHER CONDITION

Heat Transfer Enhancement by using Al 2 O 3 -Water Nanofluid in a Liquid Cooling System for Microprocessors

PERFORMANCE ANALYSIS OF PARABOLIC TROUGH COLLECTOR TUBE WITH INTERNAL INTERMITTENT FINS

Flow and Temperature Analysis inside Flat Plate Air Heating Solar Collectors

Transcription:

International Conference Passive and Low Energy Cooling 867 Study of a new concept of photovoltaic-thermal hybrid collector Y.B. Assoa, C. Menezo and R. Yezou Thermal Center of Lyon (CETHIL), Lyon, France G. Fraisse Laboratory of Optimization of the Design and Engineering of the Environment (LOCIE), University of Savoy, France T. Lefebvre SUNLAND21 Company, France ABSTRACT This work presents the first step of the development of a new concept of photovoltaic/thermal collector that will be combined with preheating air and/or water production. It consists in a simplified mathematical modeling of a PV/T air collector. The studied prototype is a component of metal sheet type which has an air gap at the backside and which can be integrated in roofs or in facades. The first step presented here consists in a parametric study (experimentally and numerically) in order to determine the effect of some factors as the air circulation (natural or forced) on the system thermal performances. Steady-state and a bidimensional geometry are considered. Then, an experimental confrontation led on a test bench permits to validate the results of the simulation and allows envisaging further development. 1. INTRODUCTION Hybrid PV/T collectors produce electricity and heat (air or water preheating). The advantage is to ameliorate the global energy efficiency of PV(/T) modules by extracting the heat loose by using a heat removal fluid (air or water). Many theoretical and experimental studies have been made on hybrid air PV/T collectors. Most of the thermal models proposed are based on a nodal approach. Thus, Mei (2003), in the analysis of a ventilated PV air collector, determined the Nusselt number corresponding to the heat transfer coefficient for forced convection by taking into account the combination of a laminar and a turbulent flow of the fluid. Guiavarch (2003) proposed a modeling of a PV hybrid air collector, which can be integrated in roofs. Hollick (1999) reported the experimental study of a solar collector composed of metal perforated and corrugated sheet steel on which a solar panel is stuck. Then, Belusko (2004) proposed the analysis of a solar air collector with a metal corrugated plate by comparing it to an unglazed solar collector. In our paper, a 2D simplified thermal model of a photovoltaic air collector is introduced. The final main function of this component will still remain production of electricity using solar energy. However, a first parametric study permits to evaluate the effect of many factors on the further thermal performances of this component especially for building air preheating configuration. Then, the results of simulation are compared to the experimental values obtained on a test bench led in controlled limit conditions. 2. COMPONENT THERMAL ANALYSIS The photovoltaic air collector studied is shown schematically in Figure 1. It consists of a ribbed sheet steel absorber on which is fixed a PV plate through a fin adhesive layer of Tedlar. There is an air gap between the absorber and an insulation layer. The prototype is investigated in two steps. First, a simplified 2D model of a non ventilated PV collector is developed. Then, the case of a ventilated air gap is considered. The models are based on a nodal approach according to some

868 International Conference Passive and Low Energy Cooling Metal sheet PV Modules y x z PV modules 4 Tedlar Insulation 0,8 Metal sheet Air gap 0,75 72 axis of symmetry T n T s2 T es2 22 T en T in Ventilation (natural or forced) Figure 1: Scheme of the prototype of PV air collector. assumptions. The inclined part of the rib is compared to a fin bathing in two different fluids at constant temperatures. The direct solar radiation G (W/m²) is supposed to be perpendicular to the collector surface. By symmetry, only half of the rib and the solar panel is taking into account in the study. 2.1 Thermal model of the non ventilated PV air collector The various layers constituting the system are represented by two or three nodes (Fig. 2). The node T c represents the sky temperature, T e represents the ambient air temperature, T ecell, T cell and T icell are for the PV modules temperature, T en, T n and T in are for the base of the rib, T ep, T p and T ip are for the metal sheet, T es, T s1, T is, T s2 and T es2 are for the polystyrene insulation, T conv, T rad and T f, are for the air gap and T iconv and T irad are for the temperature of the internal air of the building. 2.1.1 The inclined part of the rib The energy conservation equation over the inclined part of the rib is considered as a classical fin case (Ammari, 2003). The node T o is taken as the average temperature of this inclined wall. The radiation energy Q o absorbed by this node is given by: Q o =G*α o *((b 1 -b o )/2)*L (1) T e Metal fin β z T ecell T cell T icell T ip T p T ep G T conv T iconv T irad b o : width of the base of the rib, in meter b 1 : width of opening of the rib, in meter L: length of the collector, in meter α o : absorptance of steel (-) This fin effect calculation permits us to obtain the temperature T(z) function of the height z of the air gap and then at the node T o located at z =h/2 by writing the heat balance equation of the fin. T(z) =(T p -A/B)*cos(( B)*z)+(T p -A/B) *(sin(( B)*h)/cos(( B)*h)) *sin(( B)*z)+A/B (2) Where the parameters A and B are: A =(h ce *S e-o *T e +h conv *S o-conv *T conv +h rad *S o-rad *T rad +Q o )/k p *S o-p (3) B =(h ce *S e-o +h conv *S o-conv +h rad *S o-rad )/k p *S o-p (4) k i : thermal conductivity of the material i, T o T rad h=40mm T is T s1 T es Figure 2: Cross section of the PV air collector and state variables.

International Conference Passive and Low Energy Cooling 869 Temperature ( C) 180 160 140 120 100 80 60 40 20 Tecell Tip Tconv Tecellv Tipv Tf 350 500 625,4 800 900 1500 Radiation G (W/m²) Figure 3: Temperatures of PV modules, of the absorber and of air according to solar radiation G in the case of a forced (v) and of a natural ventilation. in W/m.K h i : heat transfer coefficient, in W/m².K h: height of the air gap, in m S i-j : heat exchange surface between the nodes i and j, in m² β: angle between the vertical and the inclined part of the rib, in degree. A heat balance is written in every nodes according to the phenomena of coupled heat transfers. It is divided in two parts: the first part concerns the base of the rib and the second part concerns the air gap. The equations have the following form: i K i-j *(T i -T j ) =M j *C j *(dt j /dt) for the central nodes, or I K i-j *(T i -T j ) =0 for the nodes of surface. Where the conductance is written as: K i-j =h i-j *S i-j (5) 2.1.2 Heat balance n 1 The first heat balance includes the base of the rib and the insulation layer of polystyrene. Since the tests have been carried out in a laboratory, we supposed that the local walls are at the ambient temperature T e. Then, the sky temperature is considered equal to the laboratory ambient air (T c =T e ) for radiation heat exchange equations. 0 =K rad, e-en *(T e -T en )+K n-en *(T n -T en )+K e-en *(T e -T en )+ G*α n *b o *L/2 (6) Temperature ( C) 75 70 65 60 55 50 45 40 35 30 1 2,7 4 8 10 20 Collector length (m) Figure 4: Temperature of air according to the collector length for T fin = 29,4 o C. Where: K rad,e-en : conductance for a radiation transfer between the nodes e and en, in W/K M n *C n *(dt n /dt) =K in-n *(T in -T n ) +K en-n *(T en -T n ) (7) M i : mass of the material i, in kg. C i : specific heat in J / kg K. 2.1.3 Heat balance n 2 The heat balance includes the insulation layer located under the air gap, the non ventilated air gap, the metal absorber and the photovoltaic cells. M s1 *C s1 *(dt s1 /dt) =K s1-es *(T es -T s1 ) +K s1-is *(T is -T s1 ) (8) For the non ventilated air gap, the temperature T rad is defined as the mean radiant tempera- Temperature ( C) 65 60 55 50 45 40 Tf Tf 0,5 1 2 3,7 Ventilation velocity (m/s) Figure 5: Temperature of air according to the velocity of air circulation.

870 International Conference Passive and Low Energy Cooling ture of the walls of the gap. 0 =K ep-rad *(T ep -T rad )+K o-rad *(T o -T rad )+K is-rad (T is -T rad ) (9) M air *C air *(dt conv /dt) =K ep-conv *(T ep -T conv ) +K o-conv *(T o -T conv )+K is-conv *(T is -T conv ) (10) The convective heat transfer coefficient can be obtained from the Nusselt number for fully developed laminar flow in natural convection in ducts (Ammary, 2003): Nu = 4,36. M p *C p *(dt p /dt) =K ip-p *(T ip -T p ) +K ep-p *(T ep -T p )+K o-p *(T o -T p ) (11) 0 =K cell-ecell *(T cell -T ecell )+K e-ecell *(T e -T ecell )+K rad, e-ecell *(T e -T ecell )+Q cell (12) The radiation energy absorbed by photovoltaic cells takes into account electric conversion and is given by: Q cell =G*b cell *(L/2)*α cell -E p (13) b cell : width of the solar panel, in meter. If r c is the ratio of cells area to aperture area and η cell is the temperature-dependent solar cell operating efficiency, the generated DC power E p is given by: E p =G*b cell *(L/2)*r c *η cell (14) The convective heat exchange coefficient between the cells surface and the ambient air can be obtained by the formula (Ammari, 2003): h e-ecell =3,8*u e +5,7 (15) u e : the ambient air velocity (m/s). 2.2 Modeling of the ventilated PV air collector In the case of a ventilated air gap, the air is represented by the node T f. The equations in the heat balance change only with certain nodes. Concerning the node T o, the result is similar to equation (6) but T f replaces Tconv in the formulas of the parameters A and B The ventilated air gap is represented by node T f. q m *C p *(T f -T fin )+M f *C f *(dt f /dt) =K f-is *(T f -T is )+K ep-f *(T ep -T f )+K o-f *(T o -T f ) (16) q m : mass flow rate of air in kg/s C p : specific heat of air in J/kg.K The Nusselt number Nu for forced convection in the ventilated gap can be obtained from Petukhov equation (1970) for fully developed turbulent flow in tubes or ducts. Nu=[(f/8)*Re*Pr]/[1,07+12,7 * ((f/8)*(pr 2/3-1))]*(µ/µ w ) 0,11 (17) Re: Reynolds number Pr: Prandtl number µ w : dynamic viscosity of water, in kg/m.s f: is a friction factor given by: f =(0,79*ln(Re)-1,64) 2 (18) 3. EXPERIMENTAL COMPARISON An experimental study on the prototype described was led by the Sunland21 Company on a test bench and permits to obtain experimental values of temperature in various preset points of the collector for two types of configurations. The tests were carried out in steady state and in controlled radiation conditions. 3.1 Description of the experimental device The sheet steel was placed in a box of dimensions 2,7 m x 0,6 ml x 0,45 m (Photo 1). The slope of the box is adjustable from 0 to 15. The internal walls of the box are covered with 5 mm of polystyrene. Three directional gas-discharge lamps offering a maximum power of 1500 W/m² ensure the radiation. The inten- Photo 1: Photograph of the test bench gone up by the Sunland21 Company.

International Conference Passive and Low Energy Cooling 871 Table 1: Comparison of simulation results and experimental results. Tcalculated Texp right Texp left Tecell 82,7 80 85,7 Ticell 82,6 Tip 82,5 Tep 82,4 82,4 86,7 Tconv 71,8 T(h/2)=To 82,6 80,9 81 Ten 82,7 79,2 79,2 sity of radiation was measured using a fluxmeter. The air velocity at the entry of the gap is adjustable with a ventilator from 0 to 5 m/s. For the air velocity measurement, probes speeds were used. 3.2 Analysis of simulation results 3.2.1 Non ventilated PV air collector The tests realized provided the following results for a radiation G =625 W/m² (Table 1). 3.2.2 Ventilated PV air collector The tests carried out provided the following results for a radiation G =625 W/m² and a mean velocity of ventilation of V=3,7 m/s. The inlet air temperature is of 29,4 C (Table 2). After comparison, the values obtained during the simulation are very close to the experimental values. The differences can be explained in particular by the fact that during calculations, the radiation was supposed uniformly distributed on all the surface of the collector, which was not checked during the tests carried out by the Sunland21 Company. 4. PARAMETRIC STUDY A study was undertaken on the collector for the two types of configurations in order to evaluate the influence of parameters such as the solar Table 2: Comparison of simulation results and experimental results Tcalculated Texp left Texp right Tecell 70,0 69,2 72,8 Ticell 69,8 Tip 67,7 Tep 67,7 67,7 69,2 Tf 45,5 46 48 T(h/2)=To 67,8 66,7 63,7 Ten 67,9 66,7 radiation G, the length of the gap L and the velocity of air circulation V in the gap on its thermal performances. 4.1 Effect of solar radiation G A parametric study was carried out in order to determine the influence of the radiation G on the temperature of the air at the exit of the gap, on that of the upper surface of the PV modules and on that of the back face of the absorber for a natural ventilation simulation (T conv, T ecell and T ip ) and for a forced ventilation simulation (T f, T ecellv and T ipv ) The value of radiation varies from 350 W/m² to 1500 W/m². The air velocity in the ventilated solar collector is fixed at 3,7 m/s. The analysis of the graphs obtained shows that the absorber and the PV cells curves are confused, so we can said that a good ventilation of the steel absorber is enough with cooling to PV modules. 4.2 Influence of the length of the gap on the fluid temperature A parametric study was carried out on the fluid temperature at the exit of the gap while varying the length of the ventilated PV air collector. The fluid temperature is doubled approximately when the length of the collector goes from 1 to 20 m. 4.3 Influence of air circulation velocity on the fluid temperature A study was carried out on the air temperature at the exit of the collector while varying the air velocity. The analysis of the curve shows that the air temperature decreases when the air circulation velocity increases. Compared to the variation of the collector length, the reduction in mass flow rate seems the most practical solution to increase the collector efficiency because it doesn t need to modify its dimensions. 5. CONCLUSION A mathematical model of the PV air collector presented was proposed according to whether the ventilation of the air gap is natural or forced. Then, an experimental study confirmed the values obtained during simulation. A parametric

872 International Conference Passive and Low Energy Cooling study carried out permitted to find the awaited tendencies concerning the temperature of cells and of the fluid at the outlet side of the air gap according to the velocity of ventilation, the collector length and the received radiation. We note that forced ventilation is obviously the best (in particular in summer) for the thermal efficiency of the collector. It would be also interesting to examine if natural ventilation can sufficiently support in real conditions a production of an optimal quantity of electricity. Thus, we will develop the model by integrating an electric balance. Currently, we instrument this collector in a phase of building integration (Fig. 1) within the framework of a project ADEME PUCA titled "Building at Horizon 2000" carried out in partnership with Sunland21, ARCELOR, TOTAL Energy companies and the CSTB (Building Scientific and Technical Center) laboratory. In the second part of this work, an evolution permitting to integrate a function of production of hot water will be proposed. REFERENCES Ammari, H.D. (2003). A mathematical model of thermal performance of solar air heating with slats. Renewable Energy, Karak, vol.28: pp.1597-1615. Belusko, M. (2004). Roof integrated solar heating system with glazed collector ventilated PV façade. Thèse Energétique-Environnement, Mawson Lakes, vol.76: pp.61-69. Guiavarch, A. (2003). Etude de l amélioration de la qualité environnementale du bâtiment par intégration de composants solaires, Université de Pontoise, Cergy- Pontoise, 311p.. Hollick, J.C. (1998). Solar cogeneration panels, Renewable Energy, Toronto, vol.15: pp.195-200. Mei, L. (2003). Thermal modeling of a building with an integrated ventilated PV façade, Energy and buildings, Stuttgart, vol.35: pp.605-617. Petukhov, B.S. (Hartnett JP, Irvine TF New York: Academic Press) (1970). Heat transfer and friction in turbulent pipe flow with variable physical properties, Advances in heat transfer, New York, p. 504-64.