Building physics. Reinforced concrete/reinforced concrete. Steel/reinforced concrete. Timber/reinforced concrete. Steel/steel.

Similar documents
Publ. No. T Rev. a326 ENGLISH (EN) March 6,

TREES Training for Renovated Energy Efficient Social housing

The Importance of Thermal Heat Bridges in Civil Engineering

Name Class Date. 3. In what part of the water cycle do clouds form? a. precipitation b. evaporation c. condensation d. runoff

Section 3.5 Thermal Comfort and Heat Stress

PREDICTING OVERHEATING RISK IN HOMES

QIRT th International Conference on Quantitative InfraRed Thermography

ISO INTERNATIONAL STANDARD. Thermal bridges in building construction Linear thermal transmittance Simplified methods and default values

Thermal bridges in building construction Linear thermal transmittance Simplified methods and default values

Warm surfaces warm edges Insulated glass with thermally improved edge seal

New correlations for the standard EN 1264

PROBLEM 1.2 ( ) 25 C 15 C dx L 0.30 m Ambient air temperature, T2 (C)

ISO INTERNATIONAL STANDARD

Computer Evaluation of Results by Room Thermal Stability Testing

COVENANT UNIVERSITY NIGERIA TUTORIAL KIT OMEGA SEMESTER PROGRAMME: MECHANICAL ENGINEERING

S TRUCTUR A L PR E- A N A LYSIS TA B LES

Fundamentals of Transmission Operations

Introduction to Weather Moisture in the Air Vapor Pressure and Dew Point

An examination of some aspects of the use of ISO 140 Part 4 and 7 in field measurements.

Thermal Imaging Survey. Conducted at Nottingham

Temperature and Heat. Chapter 10. Table of Contents. Chapter 10. Chapter 10. Bellringer. Objectives. Chapter 10. Chapter 10

5.2 (HUMIDITY) WEATHER EARTH SCIENCE

Laboratory Exercise #7 - Introduction to Atmospheric Science: The Seasons

Δ q = ( ψ L) HDH (1) here, Δq is the additional heat transfer caused by the thermal bridge, Ψ and L are the linear thermal transmittance and length of

GEOGRAPHY EYA NOTES. Weather. atmosphere. Weather and climate

Module 11: Meteorology Topic 5 Content: Weather Maps Notes

Determining of Thermal Conductivity Coefficient of Pressed Straw (Name of test)

3D UNSTEADY STATE ANALYSIS OF THERMAL PERFORMANCE OF DIFFERENTLY INSULATED FLOORS IN CONTACT WITH THE GROUND

Schöck Isokorb Type S22 and S16

ISO INTERNATIONAL STANDARD. Thermal performance of windows, doors and shutters Calculation of thermal transmittance Part 1: Simplified method

Hygrothermal Performance of Ventilated Cold Roofs an Experimental Study

Review: Conduction. Breaking News

5. AN INTRODUCTION TO BUILDING PHYSICS

The energy performance of an airflow window

Weather Maps. Name:& & &&&&&Advisory:& & 1.! A&weather&map&is:& & & & 2.! Weather&fronts&are:& & & & & &

EARLY AGE THERMAL CRACK CONTROL IN MASS CONCRETE

THERMAL PROPERTIES OF THERMOBLOCK 9LB25-O

ISO INTERNATIONAL STANDARD. Thermal insulation for building equipment and industrial installations Calculation rules

THERMAL PERFORMANCE TEST REPORT

3D Simulation of the Plunger Cooling during the Hollow Glass Forming Process Model, Validation and Results

PASSIVE COOLING DESIGN FEATURE FOR ENERGY EFFICIENT IN PERI AUDITORIUM

GEF2200 atmospheric physics 2018

Validation of the Advanced Calculation Model SAFIR Through DIN EN Procedure

Handout 10: Heat and heat transfer. Heat capacity

Hamid Abbasi This paper develops a series of expressions to predict the apparent strength and

Trevira Bioactive * For a plus in cleanliness and freshness. Workwear Hospital textiles. Functional apparel. Flame retardant Home textiles

CARBON COMPLIANCE. Setting an appropriate limit for zero carbon new homes. National or Regional Weather: Implications for Carbon Compliance

Extensions to the Finite Element Technique for the Magneto-Thermal Analysis of Aged Oil Cooled-Insulated Power Transformers

Chapter 5: Weather. Only Section 1: What is Weather?

METHOD OF IN-SITU MEASUREMENT OF THERMAL INSULATION PERFORMANCE OF BUILDING ELEMENTS USING INFRARED CAMERA

Lecture 07 February 10, 2010 Water in the Atmosphere: Part 1

Structural Fire Design according to Eurocodes

Greenhouse Steady State Energy Balance Model

Lecture Outline Chapter 18. Physics, 4 th Edition James S. Walker. Copyright 2010 Pearson Education, Inc.

THERMAL BRIDGE ASSESSMENTS Strachan P *, Nakhi A * and Sanders C # Glasgow G1 1XJ, Scotland. Kelvin Road, East Kilbride, G75 0RZ, Scotland

THERMAL ACTIONS. Milan Holický and Jana Marková. Czech Technical University in Prague, Czech Republic

Modeling Human Thermoregulation and Comfort. CES Seminar

Double-Skin Facade in Low-Latitude: Study on the Absorptance, Reflectance, and Transmittance of Direct Solar Radiation

Civil Engineering Design (1) Analysis and Design of Slabs 2006/7

a. Air is more dense b. Associated with cold air (more dense than warm air) c. Associated with sinking air

Laboratory Exercise #7 - Introduction to Atmospheric Science: The Seasons and Daily Weather

Manual Dew point scanner PCE-DPT 1

Thermal and mechanical modeling of thermal breaks in structural steel point transmittances

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

SAMPLE ASSESSMENT TASKS PHYSICS ATAR YEAR 11

Schöck Isokorb Type S22 and S16

INVESTIGATION OF THE PERFORMANCE OF COOLING PANELS: CEILING AND FLOOR PANElS.

Water in the Atmosphere

A fire resistance assessment case history G.C. and M.E. Giuliani

ADVANCED ROOF COATINGS: MATERIALS AND THEIR APPLICATIONS

Determination of installed thermal resistance into a roof of TRISO-SUPER 12 BOOST R

Heat Transfer. Thermal energy

Using Temperature and Dew Point to Aid Forecasting Springtime Radiational Frost and/or Freezing Temperatures in the NWS La Crosse Service Area

SEISMIC BASE ISOLATION

Test Results: Results of the test period on 06/19/16 using the Equivalent CTS Method: Thermal transmittance at test conditions (U s ):

Weather - is the state of the atmosphere at a specific time & place

Thermal mass vs. thermal response factors: determining optimal geometrical properties and envelope assemblies of building materials

FUNDAMENTALS OF HVAC

78% : component of atmosphere! 21% : 1% : Changes depending on origin of air: - originated over - originated over Ozone = O 3 Definition:

Modelling and Experimental Validation Possibilities of Heat Transfer Room Model

5) The amount of heat needed to raise the temperature of 1 gram of a substance by 1 C is called: Page Ref: 69

Energy flows and modelling approaches

Condensation Risk Analysis

Introduction. Lecture 6: Water in Atmosphere. How Much Heat Is Brought Upward By Water Vapor?

Weather, Atmosphere and Meteorology

PAPER 2 THEORY QUESTIONS

1. Base your answer to the following question on the weather map below, which shows a weather system that is affecting part of the United States.

1. A measure of a medium s stiffness (it s resistance to compression) is given in terms of the bulk modulus, B, defined by

Radiant Heating Panel Thermal Analysis. Prepared by Tim Fleury Harvard Thermal, Inc. October 7, 2003

A Global Index of Acoustic Assessment of Machines Results of Experimental and Simulation Tests

Demand Forecasting Models

CZECH TECHNICAL UNIVERSITY IN PRAGUE FACULTY OF MECHANICAL ENGINEERING DEPARTMENT OF ENVIRONMENTAL ENGINEERING

IDA ICE CIBSE-Validation Test of IDA Indoor Climate and Energy version 4.0 according to CIBSE TM33, issue 3

Societal Risk Assessment. Abstract

AR/IA 241 LN 231 Lecture 4: Fundamental of Energy

2013 Weather Normalization Survey. Itron, Inc El Camino Real San Diego, CA

Influence of material properties and boundary conditions on the dynamic thermal behaviour of a building corner

3.1 CONDITIONS FOR RIGID-BODY EQUILIBRIUM

DESIGN AND DETAILING OF COUNTERFORT RETAINING WALL

LOW E SATINÉ 5500 LOW E

Transcription:

Building physics Building physics Reinforced concrete/reinforced concrete Steel/reinforced concrete Timber/reinforced concrete Steel/steel 1

Thermal bridges Definition of thermal bridges Thermal bridges are local component areas in the building shell, in which heat loss occurs. The increased heat loss results in that the component area deviates from the even shape ( geometric thermal bridge ) or in that the component area concerned, local materials with increased thermal conductivity are present ( material-conditioned thermal bridge ). Effects of thermal bridges In the area of the thermal bridge the locally increased heat loss leads to a lowering of the inner surface temperatures. As soon as the surface temperature falls below the so-called mildew temperature θ S, mould forms. What is more, if the surface temperature falls below the dew-point temperature θ τ, then the moisture in the ambient air condenses on the cold surfaces in the form of condensate. If mould has formed in the area of a thermal bridge, then considerable impairments can occur to health for the resident due to the emitted mould spores in the room. Mould spores cause allergies and can therefore provoke allergic reactions in people, such as, for example, asthma. Through the general long-lasting daily exposure in dwellings there is a high risk that the allergic reactions will become chronic. Summarised, the effects of thermal bridges are thus: Danger of the formation of mould Danger of impairments to health (allergies etc.) Danger of occurrence of condensation Increased thermal energy loss Uninsulated cantilevered structural components With uninsulated cantilevered structural components such as, for example, reinforced concrete balconies or steel girders, the coaction of the geometric thermal bridge (cooling fin effect of the cantilever) as well as of the material-conditioned thermal bridge (breaching of the heat insulating layer with reinforced concrete or steel), there is a strong heat drainage. With this, cantilevers are among the most critical thermal bridges of the building shell. The results of uninsulated cantilevers are considerable heat losses and a significant lowering of the surface temperature. This leads to a marked increase of heating costs and a very high risk of mould in the area of the connection of the cantilever. Effective heat insulation using Schöck Isokorb The Schöck Isokorb, through its thermotechnically and statically optimised design (minimised reinforcement cross-section with optimised load-bearing capacity and employment of particularly good heat insulating materials), represents a very effective insulation of the cantilever. Heat progressions of balcony connections, from dark-coloured, cold balcony to light-coloured, warm internal area. Left: Continuous reinforced concrete floor without thermal separation. Right: Thermal separation using Schöck Isokorb 2

Thermal bridges Dew-point temperature The dew-point temperature θ τ of a room is that temperature at which the moisture present in the ambient air can no longer be held by the room air and is then released in the form of water droplets. The relative ambient air humidity is then 100 %. The areas of the air layer which have direct contact with the colder structural component surfaces, due to this contact, adopt the temperature of the cold structural component surface. If the minimum surface temperature of a thermal bridge lies below the dew-point temperature, then the air temperature directly at this point will also lie below the dew-point temperature. This has the result that the moisture held in this layer of ambient air is precipitated in the form of condensation on the cold surface: Condensation water drops out. The dew-point temperature depends only on the ambient air temperature and the ambient air humidity (see Figure 1). The higher the ambient air temperature and the higher the ambient air humidity, the higher is the dew-point temperature, i. e. the more easily condensation forms on cold surfaces. The normal ambient air climate in interior rooms on average is ca 20 C and ca 50 % relative ambient air humidity. This results in a dew-point temperature of 9.3 C. In rooms heavily loaded with moisture such as, for example, bathrooms, high humidities of 60 % and more are also reached. The dew-point temperature is correspondingly high and the risk of the formation of condensation increases. Thus the dew-point temperature with an ambient air humdity of 60 % is already 12.0 C (see Figure 1). You recognise this sensitive dependency of the dew-point temperature on the ambient air humidity very easily from the steepness of the curve in Figure 1: Already small increases of the ambient air humidity lead to a substantial increase of the dew-point temperature of the ambient air. This has as a result a significant increase of the risk of condensation on cold structural component surfaces. Mildew temperature The humidity required for the growth of mould on structural component surfaces is already achieved upwards from an an ambient air humidity of 80 %. This means, mould then forms on cold structural component surfaces, if the structural component surface is at least as cold, so that a humdity of 80 % is triggered in the directly adjacent layer of air. The temperature at which this occurs is the so-called mildew temperature θ S. Mould growth thus occurs already with temperatures above the dew-point temperature. For the atmospheric environment 20 C/50 % the mildew temperature is 12.6 C (see Figure 2) thus 3.3 C higher than the dew-point temperature. Therefore, for the avoidance of structural damage (formation of mould), the mildew temperature is more important than the dew-point temperature. It does not suffice if the interior surfaces are warmer than the dew-point of the ambient air: The surface temperatures must lie above the mildew temperature! 22 C Dew-point temperature in C Mildew temperature in C 20 C 15.3 18 C 12.6 Relative ambient air humidity ϕ in % Figure 1: Dependency of the dew-point temperature on ambient air humidity and temperature Relative ambient air humidity ϕ in % Figure 2: Dependency of the mould temperature on ambient air humidity and temperature 3

Thermal characteristic building-physical values of thermal bridges Summarised, the effects of thermal bridges are thus: Thermal effects Qualitative representation Quantitative single value Mould formation Condensation result Heat loss Isotherms with temperature scaling Heat flow lines Minimum surface temperature θ min Temperature factor ψ-value χ-value The mathematical determination of these characteristic values is possible exclusively through a thermal FE calculation of the precise existing thermal bridge. For this the geometric build-up of the structure in the area of the thermal bridge is modelled in the computer together with the thermal conductivities of the materials used. The constraints to be applied with the calculation and modelling are regulated in BS EN 10211. The FE calculation provides, along with the quantitative characteristics, also a representation of the temperature distribution within the structure (isotherm presentation) as well as the progress of the heat flow lines. The representation using the heat flow lines shows on which path through the structure the heat is lost, and it thus allows easy recognition of the thermal weak points of the thermal bridge. The isotherms are lines or surfaces of equal temperature and show the temperature distribution within the calculated structural component. Isotherms are often presented with a temperature step width of 1 C. Heat flow lines and isotherms are always perpendicular to each (see Figures 3 and 4). Figure 3: Example of a pure, geometric thermal bridge. Representation of isotherms and heat flow lines (arrows). Figure 4: Example of a pure. material-conditioed thermal bridge. Representation of isotherms and heat flow lines (arrows). 4

The minimum surface temperature θ si,min and the temperature factor The minimum surface temperature θ si,min is the lowest temperature occurring in the area of a thermal bridge. The value of the minimum surface temperature is decisive for whether condensation occurs on a thermal bridge or mould forms. The minimum surface temperature is thus a characteristic value for the humidity effects of a thermal bridge. The characteristic values θ si,min and ψ-value depend on the structural setup of the thermal bridge (geometry and thermal conductivities of the materials forming the thermal bridge). The minimum surface temeprature is, in addition, still dependent on the set outside air temperature: The lower the outside air temperature the lower is the minimum surface temperature (see Figure 5). The temperature factor is also used as an alternative to the minimum surface temperature as humidity characteristic value. The temperature factor is the temperature difference between inside and outside (θ i - θ e ) related to the temperature difference between minimim surface temperature and the outside air temperature (θ si,min - θ e ): = θ si,min θ e θ i θ e The -value is a relative value and thus has the advantage that this is dependent on the design of the thermal bridge and not, like θ si,min,on the applied outside and inside air temperatures. If one knows the -value of a thermal bridge then conversely the minimum surface temperature can be calculated with the aid of the air temperatures: θ si,min = θ e + (θ i θ e ) In Figure 5, with a constant inside temperature of 20 C, the dependency of the minimum surface temperature on the existing outside temperature is depicted for various -values. Depicted in Figure 6 is the relationship between θ si,min and, under the assumption of an outside temperature of 0 C. θ i = 20.0 1.0 θ min = 15.0 0.8 = 0.75 θmin in C θ min [ C] 10 5 0.6 0.4 0 0.2 Outside temperature θ e = 0.0 0.0 Figure 5: Dependency of the minimum surface temperature on the adjacent outside temperature. Inner temperature constant 20 C. Figure 6: For the definition of the -value 5

The thermal transmission coefficients ψ and χ The linear thermal transmission coefficient ψ ( ψ-value )indicates the per meter run. of additionally occurring heat loss of a linear-shaped thermal bridge. The point heat transmission coefficient χ ( χ-value ) indicates the additional heat loss via a point thermal bridge. Equivalent Thermal Conductivity λ eq The equivalent thermal conductivity λ eq is the overall thermal conductivity of all components of the Schöck Isokorb and is - at the same insulting element thickness - a measure for the thermal insulating effect of the connection. The smaller λ eq, the higher the thermal insulation of the balcony connection. λ eq values are determined through detailed thermal bridge calculations. Since each product has an individual geometry and placement specification, each Schöck Isokorb has an individual number. For the purpose of comparison of load bearing thermally insulating elements of varying element thickness, the equivalent resistance to heat transmission R eq is used instead of λ eq since it considers the insulating element s thickness in addition to the equivalent thermal conductivity λ eq. The larger R eq, the better thermal insulation effect. R eq is calculated from the equivalent thermal conductivity λ eq and the insulating element thickness as following: R eq = d λ eq Detailed thermal bridge calculation Where a detailed thermal bridge calculations is to be provided for the determination of ψ or values, the λ eq value can be used in modelling of the connection details. For this purpose, a homogenous rectangle of the same dimensions of the Schöck Isokorb insulting element is placed into the model in its position and the equivalent thermal conductivity λ eq assigned. Refer to figure. In this way, the building physics characteristic values of a design can be simply calculated. Representation of a sectional drawing with detailed Schöck Isokorb model Representation of a sectional drawing with substitute insulating element The calculation methodology to determine λ eq was validated based on the European Assessment Document - EAD for load bearing thermal insulating elements and - based on this - for Schöck Isokorb in a European Technical Assessment - ETA. It is possible to do the calculations using commercially available thermal bridge software by means of the thermal boundary conditions according to BS EN ISO 6946. In doing so, surface temperatures θ si and the resulting temperature factor can be calculated in addition to the heat loss through the thermal bridge (ψ value). Difference between ψ-value and λ eq The equivalent thermal conductivity λ eq of the insulating element of the Schöck Isokorb is a measure for the the heat insulating effect of the element, while the ψ-value represents a measure for the heat insulationof the complete balcony structure. The ψ-value changes with construction even if the connection element remains unchanged. Conversely, the ψ-value with firmly specified design is dependent on the equivalent thermal conductivity λ eq of the connection element: The smaller λ eq, the smaller the ψ-value (the higher the minimum surface temperature). 6

Requirements Condensation control and temperature factor Building Regulations Part L includes the requirement that minimum internal surface temperatures should be such that condensation risk is minimized and mould growth avoided. Approved Document L1A (L2A for non-residential buildings) cites the BRE Information Paper IP1/06 (Assessing the effects of thermal bridging at junctions and around openings) which includes some limiting values for : Type of building Minimum Dwellings, residential buildings, schools 0.75 Offices, retail premises 0.50 Sports halls, kitchens, canteens, buildings heated with unflued gas heaters 0.80 Details using Schöck thermal breaks show temperature factors far in excess of Part L requirements in all cases. Temperature factors can be calculated by Schöck on request to provide bespoke details that verify code compliance. Heat Losses To pass Building Control requirements in England it is necessary to demonstrate compliance with Building Regulations. The lastest version of the Building Regulations Part L (2013) and associated guidance document for residential construction Approved Document L1A (ADL1A) require that thermal bridging be included in the fabric heat loss calculations. The government Standard Assessment Procedure (SAP 2012) is the simple energy use and carbon emissions model used to provide evidence that the carbon emissions target has been achieved. The SAP calculation includes the term H TB (heat loss due to thermal bridging) which is calculated or estimated as below: a) The sum of all linear thermal transmittances (ψ) length of detail (L) or, if no linear thermal transmittances are known: H TB = (L ψ) b) Using the factor y = 0.15 in the equation below: H TB = y A exp (where A exp = total exposed fabric area) Linear thermal transmittance values (ψ) used in (a) can be a combination of: Approved Design Details if used (in Approved column of SAP Appendix K Table K1) Uncalculated details (in Default column of SAP Appendix K Table K1) Modelled details, in which numerical modelling has been carried out by a person of suitable experience and expertise. Method (a) is always preferable as it avoids the penalty imposed by (b) which can double the overall calculated heat loss in a well-insulated construction. A similar approach is taken for non-residential buildings in Part L2A, in which the Simplified Bilding Energy Model (SBEM) is used in place of SAP. One off calculations of ψ can be carried out on request for all details using Schöck thermal breaks to obtain the optimal solution. 7