Measurement of the n_tof beam profile in the second experimental area (EAR2) using a silicon detector

Similar documents
Silicon detectors for the n-tof neutron beams monitoring

Present and Future of Fission at n_tof

Neutron cross sections in stellar nucleosynthesis: study of the key isotope 25 Mg

Alpha-energies of different sources with Multi Channel Analyzer (Item No.: P )

Measurementof 7 Be(n,α) and 7 Be(n,p) cross sections for the Cosmological Li problem in

Experimental neutron capture data of 58 Ni from the CERN n TOF facility

Alpha-Energies of different sources with Multi Channel Analyzer

Be(n,a) and 7 Be(n,p) cross-sections measurement for the Cosmological Lithium problem at the n_tof facility at CERN

He-3 Neutron Detectors

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Theory English (Official)

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

Nuclear Cross-Section Measurements at the Manuel Lujan Jr. Neutron Scattering Center

Nuclear cross-section measurements at the Manuel Lujan Jr. Neutron Scattering Center. Michal Mocko

n_tof EAR-1 Simulations Neutron fluence Spatial profile Time-to-energy

Precision neutron flux measurement with a neutron beam monitor

The Possibility to Use Energy plus Transmutation Setup for Neutron Production and Transport Benchmark Studies

Nuclear Instruments and Methods in Physics Research A

The Use of Neutron Generators for the Detection of Illicit Materials in the Sea Transportation System

The possibility to use energy plus transmutation set-up for neutron production and transport benchmark studies

Flux and neutron spectrum measurements in fast neutron irradiation experiments

Neutron cross-section measurements at the n_tof facility at CERN

arxiv: v1 [physics.ins-det] 9 Apr 2018

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH. Letter of Intent to the ISOLDE and Neutron Time-of-Flight Committee

The Compton Effect. Martha Buckley MIT Department of Physics, Cambridge, MA (Dated: November 26, 2002)

The EDM Polarimeter Development at COSY-Jülich

H4IRRAD generic simulation results

GEANT4 simulation of the testbeam set-up for the ALFA detector

Principles of neutron TOF cross section measurements

Joint Institute for Nuclear Research. Flerov Laboratory of Nuclear Reactions. University Center LABORATORY WORK

Neutron induced reactions & nuclear cosmo-chronology. chronology. A Mengoni IAEA Vienna/CERN, Geneva

physics/ Sep 1997

ATLAS New Small Wheel Phase I Upgrade: Detector and Electronics Performance Analysis

Scintillation efficiency measurement of Na recoils in NaI(Tl) below the DAMA/LIBRA energy threshold

Relativistic Electrons

Geometry Survey of the Time-of-Flight Neutron-Elastic Scattering (Antonella) Experiment

Nuclear AstroPhysics at ELI-NP: preliminary experiments with ELISSA detector. Giovanni Luca Guardo

Information about the T9 beam line and experimental facilities

This paper should be understood as an extended version of a talk given at the

GAMMA DETECTORS FOR High energy Inelastic Neutron Scattering. E.M. Schooneveld

Special SLS Symposium on Detectors

BEAM BEAM. cathode anode cathode

Geant4 simulation of SOI microdosimetry for radiation protection in space and aviation environments

Recent Activities on Neutron Calibration Fields at FRS of JAERI

Tracking properties of the ATLAS Transition Radiation Tracker (TRT)

A new detector for neutron beam monitoring

Neutron capture and fission reactions on. sections, -ratios and prompt -ray emission from fission. 1 Introduction and Motivation

AGATA preamplifier performance on large signals from a 241 Am+Be source. F. Zocca, A. Pullia, D. Bazzacco, G. Pascovici

Final report on DOE project number DE-FG07-99ID High Pressure Xenon Gamma-Ray Spectrometers for Field Use

Solid state silicon + 6 LiF thermal neutron detectors: GEANT4 simulations versus real data

A gas-filled calorimeter for high intensity beam environments

Neutron Induced Nuclear Counter Effect in Hamamatsu Silicon APDs and PIN Diodes

Neutron capture cross sections of 69,71 Ga at n TOF EAR1

ORTEC. SLP Series Silicon Lithium-Drifted Planar Low-Energy X Ray Detector Product Configuration Guide

Determination of the boron content in polyethylene samples using the reactor Orphée

Relativistic Behavior Detection through Electron Acceleration

Estec final presentation days 2018

A Study of Neutron Shielding Methods for. Experimental Astrophysics

Bolometry. H. Kroegler Assciazione Euratom-ENEA sulla Fusione, Frascati (Italy)

EEE4106Z Radiation Interactions & Detection

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

GaN for use in harsh radiation environments

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Mass Determination of Rn and Hg isotopes using MASHA

CHARACTERISTICS OF LIGHT CHARGED PARTICLE EMISSION IN THE TERNARY FISSION OF 250 CF AND 252 CF AT DIFFERENT EXCITATION ENERGIES

arxiv: v1 [physics.ins-det] 9 Jan 2019

Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere. 1 Introduction

MEASUREMENT OF TEMPORAL RESOLUTION AND DETECTION EFFICIENCY OF X-RAY STREAK CAMERA BY SINGLE PHOTON IMAGES

PoS(TIPP2014)088. Diamonds for beam instrumentation. Erich Griesmayer 1. Pavel Kavrigin

Alpha-particle Stopping Powers in Air and Argon

Neutron Transport Calculations Using Monte-Carlo Methods. Sean Lourette Fairport High School Advisor: Christian Stoeckl

Total kinetic energy and fragment mass distributions from fission of Th-232 and U-233

Neutron transmission and capture measurements for 241 Am at GELINA

New measurement of the 62 Ni(n,γ) cross-section with n_tof at CERN

Examples for experiments that can be done at the T9 beam line

Joe Parker for the Cosmic Ray γ Group Kyoto University

High-energy neutron-induced fission cross sections in

Journal of Radiation Protection and Research

Los Alamos National Laboratory Facility Review

Radioactivity and Ionizing Radiation

Experiments on deflection of charged particles using silicon crystals at. Proton Synchrotron (KEK(

IFIN-HH participation at the n_tof CERN COLLABORATION (I)

THE USE OF GE DETECTORS FOR (N,XN) CROSS-SECTION MEASUREMENTS AT INTENSE AND LOW FREQUENCY PULSED NEUTRON BEAMS. Abstract

Measurement of prompt fission γ-ray spectra in fast neutroninduced

Measurement of the Proton Beam Polarization with Ultra Thin Carbon Targets at RHIC

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

DETECTORS. I. Charged Particle Detectors

Experimental study of nonlinear laser-beam Thomson scattering

Application Note. The Continuous Air Monitoring (CAM) PIPS Detector Properties and Applications

Práctica de laboratorio número 6: Non-Rutherford scattering near the MeV 12 C(p,p) 12 C resonance

Current studies of neutron induced reactions regard essentially two mass regions, identified in the chart of nuclides: isotopes in the region from Fe

EXPERIMENTAL STUDY OF NEUTRON FIELDS PRODUCED IN PROTON REACTIONS WITH HEAVY TARGETS. Nuclear Physics Institute AS CR, Rez Czech Republic

Measurement of the 62,63. Ni(n,γ) cross section at n_tof/cern

Ir TES electron-phonon thermal conductance and single photon detection

Hands on LUNA: Detector Simulations with Geant4

CVD Diamond History Introduction to DDL Properties of Diamond DDL Proprietary Contact Technology Detector Applications BDD Sensors

P-Carbon CNI Polarimeter Operation Experience

PoS(Baldin ISHEPP XXII)065

Method of active correlations in the experiment 249 Cf+ 48 Ca n

STATUS AND PERSPECTIVES OF THE N_TOF FACILITY AT CERN. Marco Calviani (CERN) and the n_tof CERN for the n_tof Collaboration

Transcription:

Measurement of the n_tof beam profile in the second experimental area (EAR) using a silicon detector Fidan Suljik Supervisors: Dr. Massimo Barbagallo & Dr. Federica Mingrone September 8, 7 Abstract A new beam line and a second experimental area (EAR) have been recently built at the neutron Time- Of-Flight (n_tof) facility at CERN. The characterization of the neutron beam in terms of spatial profile is a prerequisite for high accuracy cross-sections measurements. A silicon strip detector equipped with a neutron converter has been used to determine the beam profile as a function of incident neutron energy, in particular neutron beam profile has been measured from thermal energy up to ev. Preliminary results have been compared with those collected with a MicroMegas detector also installed during the measurement. Introduction High accuracy measurements of cross sections for neutron-induced reactions are performed at n_tof, the neutron Time-Of-Flight facility at CERN [], producing important data for several fields such as nuclear astrophysics, nuclear technology, fundamental physics and medical physics. To this end, GeV protons are accelerated at the CERN s Proton Synchrotron (PS), with typically 7 protons per pulse, and impinge on a lead target. As a result of the spallation process taking place and the subsequent moderation, a white spectrum of neutrons is produced []. Two neutron beam lines lead the neutrons to the corresponding experimental areas, the first one (EAR) located in the horizontal direction at 8 m from the target and the newly built second experimental area (EAR) reached through a shorter vertical flight path of about 9 m. The aim of this work is to determine the beam profile in EAR using a silicon strip detector. In particular it is important to determine the profile as function of incident neutron energy. neutron beam profile the detector is coupled to a LiF converter layer, deposited onto a carbon fibre plate ( mm thick), which can be seen in Figure. The converting reaction proceeds as follows: Li + n H (.7 MeV) + α (. MeV) () As depicted in Figure b, after a neutron is captured an alpha and a triton are emitted and eventually detected in the silicon strips according to the efficiency of the system. (a) (b) SiMonD detector The neutron beam profile monitor SiMonD is a x + y strip double sided silicon detector having x cm total active area and µm thickness, while each strip is mm wide []. In order to measure Figure : View of the strips of the front layer ( - ) of SiMonD and scheme of the interaction of the incoming neutron with the converter layer and detection of the produced particles. For the measurement, the neutron beam is coming from the bottom with the front layer of the detector facing directly the beam.

Laboratory test In order to get hands on the detector and the corresponding electronics, a laboratory test was conducted and the energy resolution was investigated. Figure : Scheme of the setup for the laboratory test. An Am- alpha source of 9.9 kbq was placed in a vacuum chamber, facing the SiMonD detector (see scheme of the setup in Figure ). The signals from the detector are transported through two vacuumtight feedthrough connectors to the preamplifier and subsequently to the amplifier and the multichannel analyzer (MCA). The spectrum presenting the alpha peak for each strip was collected. As an example the spectrum recorded for strip is reported in Figure. counts [a.u.] 9 8 7 Strip 8 8 Figure : Alpha source spectrum for one the strips during the laboratory test. A preliminary energy resolution was extracted for each strip and the data acquired were later on compared with values extracted during the in-beam measurement. Measurement and data analysis The measurement for the beam profile was performed in two configurations and using two different detec- Figure : Setup of the measurement (Config. B): upper position for the SiMonD detector with the neutron beam coming from the bottom. tors, SiMonD and an ancillary XY-MicroMegas, in order to be able to compare independent results. Moreover, the beam profile was measured at two different positions, where normally samples are placed during physics run at n_tof. In the first configuration (Config. A), SiMonD is placed in the lower position with respect to the Micromegas detector, facing directly the neutron beam coming from the bottom. The positions of the detectors are inverted in the second configuration shown in Figure (Config. B). In the picture, it is possible to see the vacuum chamber and the preamplifiers used for the silicon detector, as well as its actuator to insert and to remove the detector from the beam axis. After the completion of the measurement, the data analysis was performed. First, the amplitude spectrum has been investigated for all the strips, as it is presented for strip in Figure. Both alpha and triton peaks are well separated from the signals induced by background and electronic noise, nevertheless in the data analysis only the triton peak was used as a signature of the occurrence of neutron capture in the LiF sample. The stability of the detector response was checked in

counts [a.u.] Strip Figure : Amplitude spectrum for strip : each run is drawn in a different color in order to check the stability of the response of the detector. Figure 7: Gaussian fit of the triton peak for one strip of the front layer for the determination of the energy resolution. 8 8 Strip : Mean of gaussian fit run number Figure : Stability of strip. As expected, the gain has a decreasing trend but the variation is less than %. order to investigate possible degradation of the detector performances during the measurement. Indeed, since the detector is directly placed in the beam, the radiation damage in the silicon crystal lattice could affect the accuracy of the results. Figure presents the evolution of the position of the triton peak with respect to the run number for a selected strip, showing only a % change. The position of the peak is defined as being the mean of its gaussian fit. The effect of such a small change is completely negligible in terms of results provided by the measurement. The energy resolution of the strips of the detector was also determined by fitting the triton peak with a gaussian. Figure 7 shows a selected strip of the detector. Resolution (%) 8 Front Back 8 strip number Figure 8: Energy resolution for the strips of the front and back layers, which is better for central strips. FWHM E, The energy resolution defined as R = where E is the center of the peak, is reported in Figure 8 for all the strips, and it is between % and % in general. It is possible to see that the energy resolution is better for the middle strips and the results are consistent with what expected. It is important to note that each strip may have different levels of radiation damage. In order to extract the beam profile, coincidence events between strips on the front side and in the back side were taken in consideration. Prior to that, a suitable threshold in amplitude must be applied to each strip to select the triton peak, allowing the reconstruction of the X-Y neutron distribution. To this purpose, a proper time-of-flight to energy calibration had to be applied. If L [m] is the effective path and t [µs] the flight time, the non-relativistic neutron en-

Cut for tritons (strip ) Results The profile for configuration A (SiMonD in lower position) and for different energy decades, obtained by selecting corresponding intervals of time of flight, can be seen in Figure. neutron energy [ev] Figure 9: Energy deposited in strip as a function of neutron energy. In red is reported the threshold condition used for the selection of the triton peak. Reproduction of the Li(n,α)t cross section Li(n,α)t cross section data (normalized to neutron flux) 7 neutron energy (ev) Figure : Cross section of the reaction Li(n, α)t and normalized data. The curves are superimposed in the energy range from to ev. ergy E [ev] is given by []: ( ) 7, 9 L E =, () t the relativistic expression (or relativistic corrections) should be used above a few kev. The energy deposited (amplitude) as a function of the neutron energy could then be determined and the proper cuts selected, as shown in Figure 9 for strip. In order to determine the neutron energy range where the response of the detector is reliable, it has been checked how the reference Li(n, α)t cross section matches the data collected. As can be seen in Figure, it resulted that the detector could provide accurate data up to ev. - - - ev - ev 8 - - ev - ev Figure : Profile for different energy windows for config. A. The detector is not reliable anymore after ev. One observes that the profile is similar for energy decades from to ev, but it is not well reconstructed after ev, the detector being not reliable anymore beyond this energy. The profile integrated over all the energy range obtained with SiMonD is shown in Figures a and b for configurations A and B respectively. Investigating the sigma of the beam and the mean position in both directions, one observes that from the lower to the upper position the sigma of the beam increases, as expected since the beam is less focused at that position. Moreover, one can see that the shape changes slightly to a more turned and sharp ellipse, visible for example in the bottom right part of the shape. Indeed, in both configurations, the sigma of the beam is different in the two directions (the Y direction is less gaussian than the X direction), meaning that it is more elliptical rather than circular. The comparison of these first results with the ones obtained with the XY-MicroMegas detector shows that the results are compatible, since the shape and 8

- Beam profile: < En < (ev) 8 (a) SiMonD : lower position (Config. A) 8 - Beam profile: < En < (ev) 8 (b) SiMonD : upper position (Config. B) 8 I would like to express my gratitude also to Dr. M. Diakaki for her analysis using the MicroMegas detector and all the resulting discussions about the comparison of the preliminary results. Finally, I wish to thank all n_tof members for their warm welcome and for making this project possible. References 7 (c) XYMGAS : lower position (d) XYMGAS : upper position Figure : Beam profile obtained with SiMonD and XYMGAS (Courtesy of M. Diakaki) for both configurations. the behavior of the sigma of the beam are similar, increasing comparably from lower to upper position. Figures c and d present the profile integrated over the energy range for the two configurations with the XY-MicroMegas. The beam profiles obtained by the detectors for a given configuration are in agreement. [] F. Gunsing et al., Nuclear data activities at the n_tof facility at CERN, The European Physical Journal Plus () : 7 [] M. Barbagallo et al., High-accuracy determination of the neutron flux at n_tof, The European Physical Journal A () 9: [] L. Consentino et al., Silicon detectors for monitoring neutron beams in n-tof beamlines, Review of Scientific Instruments 8, 79 () [] G. Lorusso et al., Time-energy relation of the n_tof neutron beam: energy standards revisited, Nuclear Instruments and Methods in Physics Research A () - Conclusions The characterization of the n_tof beam in EAR in terms of spatial profile was performed using the silicon strip detector SiMonD, in an energy range from to ev. The extracted profile was compared with results from another detector (XY-MicroMegas) used for the measurement during the same experiment. The first comparison shows consistency of the results obtained. 7 Acknowledgements I would like to sincerely thank Dr. M. Barbagallo and Dr. F. Mingrone for their availability, help and valuable suggestions throughout this work.