TEST REPORT IES LM For Signlite Opto-electronics Co.,Ltd.

Similar documents
IES LM TEST REPORT For EIKO GLOBAL, LLC

IESLM-79-08TESTREPORT For KINGLUMI CO., LTD

IES LM TEST REPORT For Shenzhen sunper opto co., ltd

1 General 1.1 Product Information Manufacturer Maxlite.Inc Page 2 of 17 Manufacturer Address 12 York Ave West Caldwell, NJ Brand Name Luminaire

Test report of IES LM Approved Method: Electrical and Photometric

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT For

IES LM MEASUREMENT AND TEST REPORT For. IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Test Model: IGTFL

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS Jeanne Han/Safety Manager

IES LM MEASUREMENT AND TEST REPORT For. Eiko Limited W. 84th Street,Shawnee, KS, USA. Test Model: LEDP-13WPAR30/NFL/830-DIM

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W 84th St Shawnee, KS Jeanne Han/Safety Manager

IES LM MEASUREMENT AND TEST REPORT For

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-150W-50

IES LM MEASUREMENT AND TEST REPORT For. ATG Electronics Corp 9020 Rancho Park Court Rancho Cucamonga, CA Test Model: HBUF-100W-50

Photometric Test Report

Cat# LED Linear High Bay 100W

Page 2 of 14 Report No.: Test sample... : Type of test object... : LED Downlight LED Downlight

Test Report. Report No.: EED35I Page 1 of 12. Customer : Revolution Lighting Technologies : 4139 Guardian Street, Simi Valley, CA93063

TEST REPORT For Company:

Morris Products 53 Carey Road, Queensbury, NY 12804

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Photometric Test Report

Photometric Test Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For. LED Wav es,inc. (Brand Name: LED Wav es)

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Photometric Test Report. Keystone Technologies

Photometric Test Report. Keystone Technologies

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl350u1

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS350U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For SIMKAR CORPORATION. (Brand Name: ) LED Lamp. Model name(s): SALXS450U1. Model differences: N/A

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl5s50u1

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. For. Beyond LED Technology. (Brand Name: Beyond LED) 2725 Mountain Industrial Blvd. Suite A-1 Tucker, GA 30084

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For. Simkar Corporation. (Brand Name: ) LED Luminaire. Model name(s):salho2xl4s50u1

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For. Shenzhen Guanke Technologies Co. Ltd. (Brand Name: )

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report. For MaxLite Inc. LED Commercial Down lights Model: RR82540W

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

LM-79 Report TEST REPORT NO. L523A

LM-79 Report TEST REPORT NO.M037D

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MaxLed) 12 York Ave West Caldwell NJ 07006

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Photometric Test Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

LM Test Report. for. Forest Lighting Corporate. LED Tube. Model: FL-T8U BN

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Measurement method for the proficiency testing program

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Transcription:

NVLAP LAB CODE:201045-0 TEST REPORT IES LM-79-08 For Signlite Opto-electronics Co.,Ltd. 6F, Weixing industry park, No.268-3 Baoshi East Road, Shiyan subdistrict, Bao an District, Shenzhe, China. Report No.: Product Description: Electrical Rating: Model No.: Model Difference: R0117020237L1 High Bay Luminaires for Commercial and Industrial Buildings 100-277 VAC, 50/60 Hz, 200 W HB360X200RL ( X denotes CCT, X =M denotes 3000 K, X =R denotes 3500 K, X =N denotes 4000 K, X =V denotes 4500 K, X =P denotes 5000 K, X =W denotes 5700 K) All construction and rating are the same, except CCT. Test Date: 2017-02-10 to 2017-03-02 Report Date: 2017-03-20 Test Standard: Test Laboratory: LM-79-08 Shenzhen Anbotek Compliance Laboratory Limited Tested by Reviewed by Alcander Lou / Raymond Song / Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or use in part without prior written consent from Shenzhen Anbotek Compliance Laboratory Limited. This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of the Federal Government. Shenzhen Anbotek Compliance Laboratory Limited ADD: 1/F., 1/Building, SEC Industrial Park, No.0409 Qianhai Road, Nanshan District, Shenzhen, 518054, China TEL: (86)755-26066365 FAX: (86)755-26014772 EMAIL: service@anbotek.com WEB: www.anbotek.com.cn

General Information Applicant: Applicant Address: Manufacturer: Manufacturer Address: Brand Name: Tested Model: Light Source: Signlite Opto-electronics Co.,Ltd. 6F, Weixing industry park, No.268-3 Baoshi East Road, Shiyan subdistrict, Bao an District, Shenzhe, China. Signlite Opto-electronics Co.,Ltd. 6F, Weixing industry park, No.268-3 Baoshi East Road, Shiyan subdistrict, Bao an District, Shenzhe, China. Signlite HB360M200RL, HB360W200RL SL-IBEC30-EL of Shenzhen Smalite Opto-electronic Co.,Ltd. Summary of Result Test Item Luminous Flux (lm) Test Result Luminous Efficacy (lm/w) Integrating Sphere Test 25320 124.76 Goniophotometer Test 25204 125.27 Electrical Test Power Factor THDi 0.9090 21.5% Page 2 of 10

1 Test Condition 1.1 Air Temperature The ambient temperature in which measurements are being taken shall be maintained at 25 C±1 C, measured at a point not more than 1 m from the SSL product and at the same height as the SSL product. The temperature sensor shall be shielded from direct optical radiation from the SSL product and optical radiation from any other source. If measurements are performed at other than this recommended temperature, this is a non-standard condition and shall be noted in the test report. 1.2 Thermal Conditions for Mounting SSL Products The method of mounting can be the primary path for heat flow away from the device and can affect measurement results significantly. The SSL product under test shall be mounted to the measuring instrument so that heat conduction through supporting objects causes negligible cooling effects. If the SSL product under test is provided with a support structure that is designated to be used as a component of the luminaire thermal management system, the product shall be tested with the support structure attached. Any such support structure included in the measurement shall be reported. 1.3 Air Movement The incidence of air movements on the surface of a SSL product under test may substantially after electrical and photometric values. Air flow around the SSL product being tested should be such that normal convective air flow induced by device under test is not affected. 1.4 Waveshape of AC Power Supply The AC power supply, while operating the SSL product, shall have a sinusoidal voltage wave shape at the prescribed frequency (typically 50/60 Hz or 50 Hz) such that the RMS summation of the harmonic components does not exceed 3 percent of the fundamental during operation of the test item. 1.5 Voltage Regulation The voltage of an AC power supply (RMS voltage) or DC power supply (instantaneous voltage) applied to the device under test shall be regulated to within ±0.2 percent under load. 1.6 Seasoning For the purpose of rating new SSL products, SSL products shall be tested with no seasoning. 1.7 Stabilization Before measurements are taken, the SSL product under test shall be operated long enough to reach stabilization and temperature equilibrium. The time required for stabilization depends on the type of SSL products under test. The stabilization time typically ranges from 30 min to 2 or more hours for large SSL products. 1.8 Operating Orientation The SSL product under test shall be evaluated in the operating orientation recommended by the manufacturer for an intended use of the SSL product. Stabilization and photometric measurements of SSL products shall be done in such operating orientation. Page 3 of 10

2 Test Method 2.1 Integrating Sphere Measurement The integrating sphere system includes AC power source, digital power meter, DC power supply, spectrophotometer, and integrating sphere. The system is calibrated by standard lamp before measurement weekly. The standard lamp has been calibrated regularly and traced to the National Primary Standard. The 4π geometry was used to measure total luminous, luminous efficacy, chromaticity coordinates, correlated color temperature, and color rendering index, the spectral radiant flux measurements taken at 1 nm intervals over the range of 380 to 780 nm. The product was operated in its intended orientation and was recorded in the report. 2.2 Goniophotometer Measurement The goniophotometer system is calibrated by standard lamp before measurement weekly. The standard lamp has been calibrated regularly and traced to National Primary Standards. Type C goniophotometer was used for measuring total luminous flux, luminous efficacy, luminous intensity distribution, and color angular uniformity, which were calculated from the software taken at 0.5 vertical intervals and 22.5 horizontal intervals. The product was operated in its intended orientation and was recorded in the report. 2.3 Electrical Measurement According to ANSI C82.77-2002, the measurement was made using a digital power meter and power supply, the SSL product under test was operated at rated voltage and stabilized enough before measurement. The total harmonic distortion of current and power factor can be calculated from the digital power meter. The digital power meter was calibrated regularly and traced to National Primary Standards. Page 4 of 10

3 Test Result 3.1 Integrating Sphere Test at 25 C for HB360M200RL Input Voltage (V) Frequency (Hz) Current (A) Power Factor Power (W) 119.70 60 1.7220 0.985 202.90 Luminous Flux (lm) Radiant Flux (W) CCT (K) Duv Luminous Efficacy (lm/w) 25320 78030 3057-0.000029 124.76 Ra x y u v 83 0.4329 0.4026 0.2486 0.5202 R1 R2 R3 R4 R5 82 90 97 82 82 R6 R7 R8 R9 R10 88 84 62 12 78 R11 R12 R13 R14 R15 82 71 84 98 75 Page 5 of 10

3.2 Integrating Sphere Test at 25 C for HB360W200RL Input Voltage (V) Frequency (Hz) Current (A) Power Factor Power (W) 120.00 60 1.6920 0.985 199.90 Luminous Flux (lm) Radiant Flux (W) CCT (K) Duv Luminous Efficacy (lm/w) 25421 82635 6012-0.00166 127.17 Ra x y u v 88 0.3217 0.3282 0.2044 0.4692 R1 R2 R3 R4 R5 88 94 94 86 87 R6 R7 R8 R9 R10 88 89 76 33 83 R11 R12 R13 R14 R15 86 63 90 97 85 Page 6 of 10

3.3 Goniophotometer Test at 25 C for HB360M200RL Input Voltage (V) Frequency (Hz) Current (A) Power Factor Power (W) 119.86 60 1.7180 0.9770 201.20 Luminous Flux (lm) CBCP (cd) Zonal Lumen Density (20~50 ) Luminous Efficacy (lm/w) 25205 9011 52.1% 125.27 Luminous Intensity Distribution Zonal Lumen Summary Page 7 of 10

Luminous Intensity (cd) Distribution Data 0 30 60 90 120 150 180 210 240 270 300 330 360 0 9011 9011 9011 9011 9011 9011 9011 9011 9011 9011 9011 9011 9011 5 8986 8990 8969 9094 8969 8990 8986 8990 8969 9094 8969 8990 8986 10 8895 8895 8874 9011 8874 8895 8895 8895 8874 9011 8874 8895 8895 15 8712 8712 8709 8803 8709 8712 8712 8712 8709 8803 8709 8712 8712 20 8471 8476 8457 8554 8457 8476 8471 8476 8457 8554 8457 8476 8471 25 8156 8157 8147 8263 8147 8157 8156 8157 8147 8263 8147 8157 8156 30 7783 7772 7754 7864 7754 7772 7783 7772 7754 7864 7754 7772 7783 35 7318 7316 7295 7382 7295 7316 7318 7316 7295 7382 7295 7316 7318 40 6795 6785 6791 6875 6791 6785 6795 6785 6791 6875 6791 6785 6795 45 6198 6197 6229 6392 6229 6197 6198 6197 6229 6392 6229 6197 6198 50 5534 5504 5464 5578 5464 5504 5534 5504 5464 5578 5464 5504 5534 55 4779 4750 4724 4838 4724 4750 4779 4750 4724 4838 4724 4750 4779 60 3966 3909 3894 3990 3894 3909 3966 3909 3894 3990 3894 3909 3966 65 3103 3042 3021 3101 3021 3042 3103 3042 3021 3101 3021 3042 3103 70 2157 2097 2108 2178 2108 2097 2157 2097 2108 2178 2108 2097 2157 75 1236 1206 1182 1230 1182 1206 1236 1206 1182 1230 1182 1206 1236 80 448 439 438 466 438 439 448 439 438 466 438 439 448 85 41 50 45 50 45 50 41 50 45 50 45 50 41 90 0 0 0 0 0 0 0 0 0 0 0 0 0 95 0 0 0 0 0 0 0 0 0 0 0 0 0 100 0 0 8 0 8 0 0 0 8 0 8 0 0 105 0 0 8 8 8 0 0 0 8 8 8 0 0 110 0 0 0 0 0 0 0 0 0 0 0 0 0 115 33 4 4 0 4 4 33 4 4 0 4 4 33 120 0 17 0 0 0 17 0 17 0 0 0 17 0 125 8 8 4 0 4 8 8 8 4 0 4 8 8 130 0 4 12 12 12 4 0 4 12 12 12 4 0 135 17 8 8 12 8 8 17 8 8 12 8 8 17 140 17 17 0 0 0 17 17 17 0 0 0 17 17 145 17 17 8 17 8 17 17 17 8 17 8 17 17 150 0 17 8 17 8 17 0 17 8 17 8 17 0 155 17 17 12 12 12 17 17 17 12 12 12 17 17 160 17 12 17 12 17 12 17 12 17 12 17 12 17 165 17 8 17 17 17 8 17 8 17 17 17 8 17 170 17 12 17 17 17 12 17 12 17 17 17 12 17 175 8 4 17 12 17 4 8 4 17 12 17 4 8 180 11 11 11 11 11 11 11 11 11 11 11 11 11 Page 8 of 10

3.4 Electrical Test for HB360M200RL Input Voltage (V) Frequency (Hz) Current (A) Power Factor THDi 276.90 60 0.7840 0.909 21.5% 4 Test Equipment Equipment Name Manufacturer Model No Reference No Calibration Due Date Integrating Sphere (1.5m) SENSING SPR-600M SE-451 Before Use Integrating Sphere (2.0m) EVERFINE YF-1000 SE-599 Before Use Standard Lamp EVERFINE D062 SE-606 2017-07-01 Digital Power Meter YOKOGAWA WT210 SE-074 2017-04-05 Goniophotometer System SENSING GMS-3000 SE-450 Before Use Standard Lamp SENSING 110V/100W SE-465 2017-03-29 Digital Power Meter YOKOGAWA WT310 SE-381 2017-04-05 AC Power Source HUAYANG HY9010 SE-114 Before Use DC Power Source EVERFINE WY605 SE-605 2017-06-22 Temperature Sensor WALVICO HG126D SE-616 2017-09-06 Statement of Traceability: Shenzhen Anbotek Compliance Laboratory Limited attests that all calibration has been performed using suitable standards traceable to national primary standards and International System of Unit (SI). Page 9 of 10

Attachment A Product Photo *****END OF TEST REPORT***** Page 10 of 10