AIR HANDLING REFERENCE CATALOGUE PRODUCT SUMMARY COMPANY PROFILE HOW TO CONTACT US.

Similar documents
Circular duct grille

GTH. Rectangular double deflection grille QUICK FACTS

Plain diffuser. Dimensions

Circular duct grille. Dimensions. Description. Maintenance The grille should be removed to gain access to the duct.

Dimensions. Order code. Materials and finish. lindab ceiling diffusers

CDD/CDR. Circular ceiling diffuser for supply air QUICK FACTS

CDD/CDR. Single cone ceiling diffusers for supply air. Quick facts. Quick guide CDD/CDR A I R F L O W - S O U N D L E V E L

ALC. ALBATROSS Supply air terminal for large airflows

Linear diffuser. Description

GRC. Circular egg crate grille for transfer/extract air and wall/ceiling mounting QUICK FACTS

SWIFT Ceiling. Square ceiling air diffuser for supply air QUICK FACTS

Grille. Min. - max. dimensions

Plain diffuser. Dimensions

SWIFTTM. Ceiling. Square ceiling air diffuser for supply air

Slot diffuser. Type VSD35 2/2.6/B/3. with 35 mm wide slot

Multi-cone diffuser. Dimensions. Description FKD is an adjustable circular multi-cone diffuser, which is typically used for supply air.

Nozzle diffuser. Dimensions

Nozzles. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible.

Multi-cone diffuser. Dimensions

Krantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems

Nozzle diffuser. Dimensions

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air

Ceiling Diffuser. Type ADLR with circular face. Type ADLR-Q with square face 2/16/EN/8

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

Swirl Diffuser. Type SDW T 2.2/1/B/1. recommended for room heights from approx m

CIRCO. Sound-attenuating transfer unit QUICK FACTS

Air distribution systems. Radial outlet RA-N2...

Slot diffusers. Slot diffusers, Round duct diffusers. Slot diffusers. Slot diffusers LD-13, LD-14

Krantz. RL-C2 radial slot outlet. Air distribution systems

series KAT Acoustic air transfer units

Linear ceiling diffuser

DBQ Painted four four-way square square diffuseurs M A D E L

HELLA. Linear slot diffuser. Ordering codes. HELLA - Linear diffuser. Linear Diffusers 1 / 18. Example of the ordering code HELLA B-0-0-AN

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

Variable swirl diffusers

Air distribution systems. Linear whirl outlet WL...

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

Swirl diffusers, Variable swirl diffusers

Krantz. Radial slot outlet with square blade array RL-Q2... circular blade array RL-R2... Air distribution systems DS 4186 E 09.

Air distribution systems. Jet nozzle DW-N2... Swivel jet nozzle DW-V2... Twist nozzle DW-V2-...-DR

Air distribution systems. Adjustable induction outlet IN-V...

Supply air nozzle. Dimensions. DAD-0 With flange for mounting on a wall or duct side.

Step Impulse Diffuser Model SIA

KSV. Slot diffusers. Ordering code. Description. Linear diffusers 1 / 16

The diagram below. to the by the. outlet into. calculation. Since TRANSMISSION VIA STRUCTURE. Vibration Via Supports Duct Breakout

VK2 volume flow controller Overview

Valve Supply and exhaust air

SV-2, SV-1, AVS, AVSL, SI Grilles

Swirl diffusers, Variable swirl diffusers Swirl diffusers

Air distribution systems. Adjustable radial outlet RA-V...

NOP, NOT and NOX. Adaptable, flexible supply air diffusers with ultra low height for free installation. climecon.fi 07.16

series 50-PR Square perforated face diffusers

series FLOOR

Krantz Components. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems

Displacement Flow Diffusers

Ventilating grilles, Ventilating valves

Siv-inn School. Complete air-supply solution for school premises. Ensures excellent air supply Cleanable Reinforced front Ideal for renovation work

Krantz. Variable twist outlet with guide ring DD-VL... jet straightener DD-VG... Air distribution systems

zehnder stratos CS CS CS CSW CSW Product Overview Model Code (example)

AX6 adjustable blades swirl diffusers

Swirl Diffusers Type DLA 7 and DLA 8

FIXED ROUND CEILING DIFFUSERS & GRILLES APPLICATION

DCG adjustable core circular diffusers

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1

KSAb

Mechanical flow-rate controllers

AXO adjustable vanes swirl diffusers

BNA Series. PLENUM FAN with Backward Wheels

KZMb

KZPb

Addendum to ARI Standard , Air Terminals September 2002

Cabinets G " integrated in upright Handle strip in side panel Easy solution for shortened doors

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1

2/S12 DIFFUSER FOR HORIZONTAL OR VERTICAL DISCHARGE DHV. v 3.3 (en)

Worth noting. Introduction. Key figures. lindab architect. Picture 1. Architect Circum, Luna and Prisma.

STAIRCASE SWIRL DIFFUSERS

Twin City Fan Companies. Fan System Effects

SWIRL DIFFUSERS SWIRL DIFFUSERS OD-8

Hudevad P100. Technical datasheet

Air Diffusion Designing for Comfort

Connections Standard. Description

Industrial Air Diffuser Type DLD for Heating and Cooling

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.

Use. Worth noting. Key figures. Installation. lindab fasadium

Positive Signal The most technologically advanced. double coated dichroic filters are used, which transmit

AIR TECH SYSTEMS. Technical Brochure. LTG Air Diffusers. Linear air diffusers LDB. Installation in ceilings, walls and sills

EXPERIMENTAL INVESTIGATION OF NOISE PARAMETERS IN HVAC SYSTEMS

NEO-V. Smoke Control Damper SMOKE CONTROL FUNCTION APPLICATION DESCRIPTION. in libraries of

Ventilating grilles, Ventilating valves

PET PETI PET/PETI. Supply air diffuser for ceilings

Laboratory for Acoustics. Determination of the sound insulation of sliding door constructions, manufactured by Metaflex

Installation guide 862 MIT / MIR

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

42C/V. Fan Coil Unit 42C/V

Schlüter -KERDI-SHOWER. System components for floor level showers

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

8.6 Product data sheet

Introduction...COMB-2 Design Considerations and Examples...COMB-3

MEASUREMENTS OF SOUND ABSORPTION TIMBERCRETE

Transcription:

AIR HANDLING REFERENCE CATALOGUE PRODUCT SUMMARY COMPANY PROFILE HOW TO CONTACT US www.bradflo.com.au

HOME 1 GRILLES & LOUVRES GRILLES & LOUVRES Chapter Description Product Code 1.11 Double deflection grille AUR 1.12 Double deflection grille AUS2 1.21 Slimline wall grille ASG 1.22 Slimline floor grille ASGF 1.31 Return air grille ARG 1.32 Egg crate grille (13mm) AEC 1.33 Egg crate grille (15mm) AECL 1.41 Curved blade register ACB 1.51 Acoustic transfer grille ATJ 1.52 Aluminium door grille AADR 1.61 Weather louvre AWL 1.62 Vertical weather louvre AWLV 1.63 Double trap weather louvre AWLD 1.64 Slimline weather louvre AWLS 2 DIFFUSERS 3 PLENUMS 4 FITTINGS & ACCESSORIES Dampers, Equalisers & Measures 5 FLEXIBLE DUCTING

DOUBLE DEFLECTION GRILLE 1.11 AUR Selection Guide Sound Selection Chart Min 25 35 NR db MAX Recommended l/s 0 X 1 4 X 1 600 X 0 600 X 0 900 X 0 X 0 Size Δ T = 8 o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..Y (X & Y are the nominal neck sizes of the grille, see overleaf.) Example: If your requirement is for a 12 x 12 (0mm x 0mm) grille with a removable core, the ordering code would be AURR1212 (When ordering it is not necessary to include the periods [..]) Specials: Curved face grilles (AURC) to suit round rigid ducting and other sizes are available upon request. Please contact your nearest branch. "Type" "X" Size 04 (0) Product Size Numbers 06 (1) "Y" Size 08 (0) (2) 12 (0) 14 (3) 16 (400) 18 (4) (0) 24 (600) Colour AUR (Fixed core) (2) Powdercoate white AURR (Removeable core) 12 (0) 14 (3) 16 (400) 18 (4) (0) Special 24 (600) Special Page 1

1.11 AUR DOUBLE DEFLECTION GRILLE Description The 1.11 (AUR) grilles are designed for use in supply and return air applications. Double deflection grilles have horizontal front blades and vertical rear blades. The AURR type grille has a removable core for cleaning or installation. Standard finishes are natural anodised or powdercoat white. There are 15 other colours available at no additional cost. Please contact your nearest Bradflo branch for the selection range. Other non-standard colours are available upon request. All grilles feature attractively designed extruded aluminium features. The blades are aerodynamically designed to provide optimum air flow and low sound pressure level performance. Design dimensions Page 2

DOUBLE DEFLECTION GRILLE 1.11 AUR Ceiling b h b v Wall Plan view Wall Side elevation L bh L bv 0 0 blowing b h = L 0.3 x 0.3 L bh = L 0.3 x 0,5 45 0 blowing b h = L 0.3 x 1.5 L bh = L 0.3 x 0,5 0 0 blowing b v = L 0.3 x 0.09 L bv = L 0.3 x 0,5 0 0 blowing b v = L 0.3 x 0.06 L bv = L 0.3 x 0,4 Free Area of AUR Grille (m 2 ) Y/X 0 400 4 0 600 7 900 1 0.029 0.038 0.043 0.048 0.058 0.072 0.087 0.116 0 0.038 0.051 0.058 0.064 0.077 0.097 0.116 0.156 2 0.048 0.065 0.073 0.081 0.097 0.122 0.146 0.195 0 0.058 0.078 0.088 0.097 0.117 0.147 0.176 0.235 400 0.078 0.4 0.117 0.1 0.157 0.196 0.236 0.314 Free area for standard size double deflection grilles. Free area correction factor f 1 Free Area Factor To calculate the free area, the grille s nominal area is multiplied by f 1, where f 1 is a correction factor and is determined by the graph. For single deflection the nominal size is the grille s Y dimension. For double deflection it is the grille s X dimension. Example: Size 0 x 1 single deflection. From the graph, f 1 = 0.79 for the grille height of 1. The grille s free area is therefore: 0/00 x 1/00 x 0.79 = 0.0355m 2. For a double deflection include the factor f 1 for the grille length. The free area would therefore be: 0/00 x 1/00 x 0.79 x 0.80 = 0.0284m 2. Correction Factor 0.82 0.8 0.78 0.76 0.74 0.72 0 0 0 0 400 0 600 700 Nominal Size Page. 3

1.11 AUR DOUBLE DEFLECTION GRILLE Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Throw is given for equal slots in each direction. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. Performance data (0 0 deflection) Static Pressure (Pa) 0.05 0.08 0.12 0.18 0.03 0.04 0.06 0.1 0.15 0.24 0.33 40 35 25 25-5 5-6 - 12 15 - - 40 2 4-8 12-24 - 1 8-16 0 0 0 00 00 00 Performance data (22 0 deflection) Static Pressure (Pa) 40 0.05 0.08 0.12 0.18 0.03 0.04 0.06 0.1 0.15 0.24 0.33 35 4-8 25 12-24 15-5 3-6 - 2-4 8-16 2 6-12 1 5-0 0 0 00 00 00 Page 4

DOUBLE DEFLECTION GRILLE 1.11 AUR Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Throw is given for equal slots in each direction. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. Performance data (45 0 deflection) Static Pressure (Pa) 35 0.05 0.08 0.12 0.18 0.03 0.04 0.06 0. 0.15 0.24 0.33 5 2-4 6-12 8-16 - 5-2 4-8 3-6 1 0 0 0 00 00 00 Page. 5

DOUBLE DEFLECTION GRILLE 1.12 AUS2 Selection Guide Sound Selection Chart Min 25 35 NR db MAX Recommended l/s 0 X 1 4 X 1 600 X 0 600 X 0 900 X 0 X 0 Size Δ T = 8 o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..Y (X & Y are the nominal neck sizes of the grille, see overleaf.) Example: If your requirement is for a 12 x 6 (0mm x 1mm) grille, the ordering code would be AUS216 (When ordering it is not necessary to include the periods [..]) Specials: Special sizes are available up to a maximum of 0mm in the Y dim and 2400mm in the X dim. Please contact you nearest Bradflo office. 06 (1) 08 (0) Product Size Numbers (2) 12 (0) "Y" Size 14 (3) "Type" "X" Size Colour AUS2 (Fixed core) 12 (0) white 14 (3) 16 (400) 18 (4) (0) 16 (400) 22 (5) Special 24 (600) Special 26 (6) 28 (700) (7) 32 (800) 34 (8) 36 (900) 18 (4) (0) Page. 6

1.12 AUS2 DOUBLE DEFLECTION GRILLE Description The 1.12 (AUS2) grilles are designed for use in supply and return air applications. Double deflection grilles have horizontal front blades with vertical rear blades. All grilles feature attractively designed extruded aluminium features. The blades are designed to provide optimum air flow and low sound pressure level performance. Standard finishes are natural anodised or powdercoat white. There are 15 other standard colours available at no extra cost. Please contact your nearest Bradflo branch for colour selection. Other non standard sizes and finishes are available as special upon request. Design dimensions Page. 7

DOUBLE DEFLECTION GRILLE 1.12 AUS2 Engineering Graphs Throws shown are to a terminal velocity of 0.25 m/s. Performance data (AUS2) Static Pressure (Pa) 1 2 3 4 5 6 7 8 9 45 5 15 25 35 15 25 45 40 35 2 5 1 0 0 0 00 00 00 These graphs are for selection only and should not be used for commissioning. Example: An airflow of 0 l/s using size No.6 will give a pressure drop of 6Pa, an NR rating of 18 and a throw of 11 metre with a terminal velocity of 0.25 m/s. Performance Nomogram Notes: (i) Throw data is in metre at a terminal velocity of 0.25 m/s. (ii) Deflection is 0 0 (iii) Throws are based on isothermal air supply. ASPECT TABLE FOR SIZE NUMBERS Width (mm) Height (mm) X/Y 0 1 0 2 0 3 400 4 0 5 600 0 1.00 2 1.25 2.00 0 1. 2.25 3.00 3 1.75 2. 3. 4.00 400 2.00 3.00 4.00 4.25 4 2.25 3.25 4.00 4. 0 2. 3.75 4.25 5.00 5. 5 2.75 4.00 4. 5.25 5.75 600 3.00 4.00 4.75 5. 6.00 6.25 6 3.25 4.25 5.00 5. 6.00 6.25 6. 700 3. 4. 5.25 5.75 6.25 6. 6.75 7.00 7.25 7 3.75 4. 5.25 6.00 6.25 6. 6.75 7.25 7.25 8.00 800 4.00 4.75 5. 6.00 6.25 6.75 7.00 7. 8.00 8.25 8 4.00 5.00 5.75 6.25 6. 6.75 7.25 7.75 8.25 8. 9.00 900 4.00 5.00 6.00 6.25 6. 7.00 7. 8.00 8. 9.00 9.00 9 4.25 5.25 6.00 6.25 6.75 7.25 7.75 8.25 8.75 9.00 9.25 00 4.25 5.25 6.00 6. 6.75 7.25 8.00 8. 9.00 9.25 9. 4. 5. 6.00 6. 7.00 7. 8.25 8.75 9.00 9.25 9. 10 4. 5. 6.25 6. 7.00 7.75 8.25 9.00 9.25 9. 9.75 11 4.75 5.75 6.25 6.75 7.25 8.00 8. 9.00 9.25 9. 9.75 4.75 6.00 6.25 6.75 7. 8.25 8.75 9.00 9. 9.75.00 Page. 8

SLIMLINE WALL GRILLE 1.21 ASG Selection Guide Sound Selection Chart Min 25 35 NR db MAX Recommended l/s 75 0 1 0 2 400 Size Vertical X 1 m Δ T = 4 o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..Y (X & Y are the nominal neck sizes of the grille, see overleaf.) Example: If your requirement is for a 12 x 8 (0mm x 0mm) standard 15 0 deflection grille, the ordering code would be AAF18. (When ordering it is not necessary to include the periods [..]) "Type" "X" Size 04 (0) Product Size Numbers 06 (1) "Y" Size 08 (0) (2) 12 (0) 14 (3) 16 (400) 18 (4) (0) 24 (600) Colour ASF(Zero deflection) (2) Powdercoate white AAF(15 o deflection) 12 (0) Natural anodised AST (0 o (extra slim blade) 14 (3) AAT (15 o extra slim blade) 16 (400) 18 (4) (0) Special 24 (600) Special Page. 9

1.21 ASG SLIMLINE WALL GRILLE Description Model 1.21 (ASG) grilles have been designed for use in supply, return or exhaust air applications. They are recommended for side wall, or sill mounting. All grille core assemblies are mounted in a sturdy frame and can be either fixed core for security purposes or removable core for easy access. For Y sizes over 0mm and X sizes over mm the core is fixed. The grilles are manufactured from high quality aluminium extrusion with a choice of four blade styles with 0 o or 15 o air stream. Standard finishes are natural anodised and white electrostatic powdercoat. There are also 15 other colours available at no additional cost. Contact your local Bradflo branch for any special requirement you may have. Blade profiles available Page.

SLIMLINE WALL GRILLE 1.21 ASG Ceiling b h b v Wall Plan view Wall Side elevation L bh L bv 0 0 blowing b h = L 0.3 x 0.3 + X L bh = L 0.3 x 0,6 0 0 blowing b v = L 0.3 x 0.09 + Y L bv = L 0.3 x 0,5 X = Nominal width Y = Nominal height Sound data NR levels for the grille may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: L w = NR + K ok Correction table for grilles of length other than 1 metre Grille length (m) 0.5 1 1.5 2 3+ Add to NR value -3 0 +2 +3 +5 Multiply throw by 0.8 1 1.2 1.35 1.5 Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 All +6 +5 +3-2 -8-13 -15 Tol +/- 2 2 2 2 2 2 2 Correction factor k ok Free Area Factor To evaluate the free area, the grilles nominal area is multiplied by f 1 where f 1 is a correction factor and is determined by the graph. 0.82 0.8 0.78 Correction Factor 0.76 0.74 0.72 0 0 0 0 400 0 600 700 Nominal Size Page. 11

1.21 ASG SLIMLINE WALL GRILLE Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Throw is given for equal slots in each direction. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. ASF grille x 00 mm long ( X dim) 1 0 Static Pressure (Pa) 75 0 125 1 0 2 0 400 25 35 9-18 8-16 7-14 6-12 5 3-6 5-4 - 8 1 0 0 0 00 00 00 For return or exhaust air, the pressure drop and noise level may be calculated as follows. Pressure drop Noise level P dra = P d x 1.2 NR ra = NR + 8 Page. 12

SLIMLINE FLOOR GRILLE 1.22 ASGF Selection Guide Sound Selection Chart Min 25 35 NR db MAX Recommended l/s 75 0 1 0 2 400 Size Vertical X 1 m Δ T = 4 o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..Y (X & Y are the nominal neck sizes of the grille, see overleaf.) Example: If your requirement is for a 12 x 8 (0mm x 0mm) standard 15 0 deflection grille, the ordering code would be AAFF18. (When ordering it is not necessary to include the periods [..]) "Type" "X" Size Product Size Numbers 04 (0) "Y" Size 06 (1) 08 (0) (2) 12 (0) 14 (3) 16 (400) 18 (4) (0) 24 (600) Colour ASFF(0 o deflection ) (2) AAFF(15 o deflection ) 12 (0) Powdercoat ASTF (0 o slim blade ) 14 (3) White AATF (15 o slim blade ) 16 (400) ASIF (0 o deflection ) 18 (4) AAIF (15 o deflection ) (0) ASIF (0 o slim blade ) 24 (600) Special AAIF (15 o slim blade ) Special Page. 13

1.22 ASGF SLIMLINE FLOOR GRILLE Description Model 1.22 (ASGF) grilles have been designed for use in supply, return or exhaust air applications. They are recommended for floor mounting. (for wall mounting refer section 1.21 (ASG). All grille core assemblies are mounted in a sturdy frame and can be either fixed core for security purposes or removable core for easy access. For Y sizes over 0mm and X sizes over mm the core is fixed. The grilles are manufactured from high quality aluminium extrusion with a choice of four blade styles with 0 o or 15 o air stream. Standard finishes are natural anodised and white electrostatic powdercoat. There are also 15 other colours available at no additional cost. Contact your local Bradflo branch for any special requirement you may have. Flanged frame I frame Blade profiles available Important! The ASGF floor grille (1.22) has been designed to withstand an evenly distributed load of 70 kg with a built in safety factor of two (2). If the load on the grille is likely to exceed 70 kg then that load should be specified at the time of ordering for specific design and pricing. Page. 14

SLIMLINE FLOOR GRILLE 1.22 ASGF Wall L bh L bv b h b v Front elevation Floor Side elevation Floor 0 0 blowing b h = L 0.3 x 0.3 + X L bh = L 0.3 x 0,6 0 0 blowing b v = L 0.3 x 0.09 + Y L bv = L 0.3 x 0,5 X = Nominal width Y = Nominal height Sound data NR levels for the grille may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: L w = NR + K ok Correction table for grilles of length other than 1 metre Grille length (m) 0.5 1 1.5 2 3+ Add to NR value -3 0 +2 +3 +5 Multiply throw by 0.8 1 1.2 1.35 1.5 Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 All +6 +5 +3-2 -8-13 -15 Tol +/- 2 2 2 2 2 2 2 Correction factor k ok Free Area Factor To evaluate the free area, the grilles nominal area is multiplied by f 1 where f 1 is a correction factor and is determined by the graph. 0.82 0.8 0.78 Correction Factor 0.76 0.74 0.72 0 0 0 0 400 0 600 700 Nominal Size Page. 15

1.22 ASGF SLIMLINE FLOOR GRILLE Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Throw is given for equal slots in each direction. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. ASGF grille x 00 mm long ( X dim) 1 0 Static Pressure (Pa) 75 0 125 1 0 2 0 400 25 35 9-18 8-16 7-14 6-12 5 3-6 5-4 - 8 1 0 0 0 00 00 00 For return or exhaust air, the pressure drop and noise level may be calculated as follows. Pressure drop Noise level P dra = P d x 1.2 NR ra = NR + 8 Page. 16

RETURN AIR GRILLE 1.31 ARG Selection Guide Sound Selection Chart Min 25 35 NR db MAX Recommended l/s 2 X 1 2 X 2 400 X 0 600 X 4 600 X 600 Size 00 X 00 Δ T = o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..Y (X & Y are the nominal neck sizes of the grille, see overleaf.) Example: If your requirement is for a 18 x 24 (4 x 600) return air grille, the ordering code would be ARG1824. {When ordering it is not necessary to include the periods [..])Special sizes are available upon request. Please contact your nearest Bradflo office. "Type" "X" Size 14 (3) Product Size Numbers 16 (400) "Y" Size 18 (4) (0) 24 (600) (7) 36 (900) Colour ARG 14 (3) Powdercoate white ARGF (with filter) 16 (400) 18 (4) (0) 24 (600) Special sizes Special colours Page. 17

1.31 ARG RETURN AIR GRILLE Description The 1.31 (ARG) grilles are designed for use in exhaust or return air situations, and may be mounted in a wall or ceiling. This grille is an attractive, robust unit manufactured from aluminium extrusion and powder coated to provide a long lasting finish. The core is removable as standard for Y sizes up to and including 00mm. Standard finish is white electrostatic powdercoat. There are also 15 other colours to choose from at no additional cost. Contact your local Bradflo branch for any special requirement you may have. Air Filtration A filter is offered as a standard option in removable core grilles. This filter is easily removed for cleaning, easy access or replacement. General Description The filter media is manufactured in a synthetic nonwoven material. It offers low air resistance, long life and satisfactory dust extraction efficiency with particular emphasis on the collection of fluff, linters and pollens. Physical Properties of filter material Temperature resistance: 1 o C constant. Fire resistance: Manufactured in fire retardent resin system. Performance When tested to AS1132-1973 methods 2 and 4 the following results were obtained. Initial resistance at 1.8 m/s was 27 Pa When loaded to a final resistance of 125 Pa the average resistance was found to be 53.7% and the dust holding capacity 290 g/m2. Note! AS1132 method 4 uses test dust #4. Design dimensions Page. 18

RETURN AIR GRILLE 1.31 ARG Free area correction factor Correction Factor 0.82 0.8 Free Area Factor To calculate the free area, the grilles nominal area is multiplied by f 1, where f 1 is a correction factor and is determined from the graph. 0.78 0.76 0.74 0.72 0 0 0 0 400 0 600 700 Nominal Size Free Area of ARG Grille (m 2 ) Y/X 2 0 400 600 7 900 00 1 0.026 0.031 0.041 0.046 0.062 0.092 0.013 0.123 2 0.047 0.056 0.075 0.084 0.113 0.169 0.188 0.225 0 0.057 0.069 0.092 0.3 0.138 0.7 0.2 0.276 4 0.089 0.7 0.143 0.160 0.214 0.321 0.356 0.428 600 0.121 0.145 0.193 0.217 0.289 0.434 0.482 0.579 900 0.184 0.2 0.294 0.331 0.044 0.661 0.735 0.882 00 0.5 0.246 0.327 0.368 0.491 0.737 0.819 0.982 0.247 0.296 0.395 0.444 0.592 0.888 0.987 1.184 The graphs are for selection only and should not be used for commissioning. Sound data NR levels for the grille may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 All +5 +7 +4-3 -8-12 -15 Tol +/- 2 2 2 2 2 2 2 Correction factor K ok L w = NR + K ok Page. 19

1.31 ARG RETURN AIR GRILLE Performance data 1 0 Static Pressure (Pa) 0.04 0.06 0.09 0.14 0.18 0.27 0.36 0.56 0.80 1.00 1.44 25 35 5 1 0 0 0 00 00 00 The graphs are for selection only and should not be used for commissioning. Page.

EGG CRATE GRILLE 13mm 1.32 AEC Selection Guide Sound Selection Chart Min 25 35 NR db MAX Recommended l/s 1 X 1 0 X 0 0 X 0 Size 4 X 4 600 X 600 900 X 900 Δ T = 12 o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..Y (X & Y are the nominal neck sizes of the grille, see overleaf.) Example: If your requirement is for a 18 x 24 (4 x 600) egg crate grille, hinged with a filter, the ordering code would be AEHF1824. {When ordering it is not necessary to include the periods [..])Special sizes are available upon request. Contact your nearest Bradflo office. "Type" "X" Size 6" (1) 8" (0) Product Size Numbers " (2) "Y" Size 12" (0) 14" (3) 16" (400) 18" (4) " (0) 24" (600) 28" (700) 36" (900) 40" (00) Colour AEC (Fixed core) 6" (1) Powder AECS (Ceiling Clip) 8" (0) coat AECRC (Removeable core) " (2) white AEHF (Hinged with filter) 12" (0) AEH (Hinged with no filter) 14" (3) AECRI (Removeable inner) 16" (400) AECR (Removeable grille) 18" (4) " (0) Special Special sizes 24" (600) colours Page. 21

1.32 AEC EGG CRATE GRILLE 13mm Description The 1.32 (AEC) grilles are designed for use in exhaust or return air situations and may be mounted in walls or ceilings. They are not to be used for floor mounting. The grilles have extruded aluminium frames with a 13mm x 13mm x 13mm aluminium egg crate core. Hinged models are available as standard and provide easy access to filters or other equipment. Grilles up to 600mm x 600mm are available with spring retaining clip for fast and efficient mounting in ceilings. The free area of the grille is >90% of the nominal area, providing maximum air flow and very low noise levels. Finish Standard finish is white electrostatic powdercoat. There are also 15 other colours to choose from at no additional cost. Contact your local Bradflo branch for any special requirement you may have. Design dimensions Page. 22

EGG CRATE GRILLE 13mm 1.32 AEC Air Filtration A filter is offered as a standard option in removable and hinged core grilles. This filter is easily removed for cleaning, easy access or replacement. General Description The filter media is manufactured in a synthetic nonwoven material. It offers low air resistance, long life and satisfactory dust extraction efficiency with particular emphasis on the collection of fluff, linters and pollens. Physical Properties of filter material Performance When tested to AS1132-1973 methods 2 and 4 (Report No. 1558/95), the following results were obtained. Initial resistance at 1.8 m/s was 35 Pa When loaded to a final resistance of 2 Pa the average resistance was found to be 85.3% and the dust holding capacity 411 g/m2. Note! AS1132 method 4 uses test dust #4. Sound data NR levels for the grille may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 All +14 +14 +6-8 -5-4 -8 Tol +/- 2 2 2 2 2 2 2 Correction factor K ok L w = NR + K ok Performance data 1 0 Static Pressure (Pa) Square size (mm) 1 0 2 0 3 4 0 600 7 35 900 25 5 1 0 0 0 00 00 00 These graphs are for selection only and should not be used for commissioning. Page. 23

EGG CRATE GRILLE 15mm 1.33 AECL Selection Guide Sound Selection Chart Min 25 35 NR db MAX Recommended l/s 1 X 1 0 X 0 0 X 0 Size 4 X 4 600 X 600 900 X 900 Δ T = 12 o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..Y (X & Y are the nominal neck sizes of the grille, see overleaf.) Example: If your requirement is for a 18 x 24 (4 x 600) egg crate grille, hinged with a filter, the ordering code would be AELHF1824. {When ordering it is not necessary to include the periods [..])Special sizes are available upon request. Contact your nearest Bradflo office. "Type" "X" Size 6" (1) 8" (0) Product Size Numbers " (2) "Y" Size 12" (0) 14" (3) 16" (400) 18" (4) " (0) 24" (600) 28" (700) 36" (900) 40" (00) Colour AECL (Fixed core) 6" (1) Powder AECLS (Ceiling Clip) 8" (0) coat AECLRC (Removeable core) " (2) white AELHF (Hinged with filter) 12" (0) AELH (Hinged with no filter) 14" (3) AECLRI (Removeable inner) 16" (400) AECLR (Removeable grille) 18" (4) " (0) Special Special sizes 24" (600) colours Page. 24

1.33 AECL EGG CRATE GRILLE 15mm Description The 1.33 (AECL) grilles are designed for use in exhaust or return air situations and may be mounted in walls or ceilings. They are not to be used for floor mounting. The grilles have extruded aluminium frames with a 15mm x 15mm x 13mm aluminium egg crate core. Hinged models are available as standard and provide easy access to filters or other equipment. Grilles up to 600mm x 600mm are available with spring retaining clip for fast and efficient mounting in ceilings. The free area of the grille is >90% of the nominal area, providing maximum air flow and very low noise levels. Finish Standard finish is white electrostatic powdercoat. There are also 15 other colours to choose from at no additional cost. Contact your local Bradflo branch for any special requirement you may have. Design dimensions Page. 25

EGG CRATE GRILLE 15mm 1.33 AECL Air Filtration A filter is offered as a standard option in removable and hinged core grilles. This filter is easily removed for cleaning, easy access or replacement. General Description The filter media is manufactured in a synthetic nonwoven material. It offers low air resistance, long life and satisfactory dust extraction efficiency with particular emphasis on the collection of fluff, linters and pollens. Physical Properties of filter material Performance When tested to AS1132-1973 methods 2 and 4 the following results were obtained. Initial resistance at 1.8 m/s was 35 Pa When loaded to a final resistance of 2 Pa the average resistance was found to be 85.3% and the dust holding capacity 411 g/m2. Note! AS1132 method 4 uses test dust #4. Sound data NR levels for the grille may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 All +14 +14 +6-8 -5-4 -8 Tol +/- 2 2 2 2 2 2 2 Correction factor K ok L w = NR + K ok Performance data 1 0 Static Pressure (Pa) Square size (mm) 1 0 2 0 3 4 0 600 7 35 900 25 5 1 0 0 0 00 00 00 These graphs are for selection only and should not be used for commissioning. Page. 26

CURVED BLADE REGISTER 1.41 ACB Selection Guide Sound Selection Chart Min 25 35 NR db MAX Recommended l/s 0 X 0 2 X 2 0 X 0 400 X 400 0 X 0 600 X 600 Size Δ T = 8 o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..Y (X & Y are the nominal neck sizes of the grille, see overleaf.) Example: If your requirement is for a 12 x 12 (0mm x 0mm) curved blade (2 way blow) grille, the ordering code would be ACB2B1212. {When ordering it is not necessary to include the periods [..]) Specials: Special sizes are available upon request. Please contact your nearest Bradflo office. "Type" "X" Size Product Size Numbers 06 (1) "Y" Size 08 (0) (2) 12 (0) 14 (3) 16 (400) 18 (4) (0) 24 (600) Colour ACB2B (2 way blow) 06 (1) Powdercoate white ACBMB (Multi blow) 08 (0) Special colours (2) 12 (0) 14 (3) 16 (400) 18 (4) (0) Special 24 (600) Note! Shaded areas indicate standard product. Page. 27

1.41 ACB CURVED BLADE REGISTER Description Model 1.41 (ACB) grilles have been designed for supply air situations and are especially suited for evaporative cooling systems. These grilles are available in 1, 2, 3 or 4 way air flow patterns. The ACB2B may be configured to a 1 or 2 way blow and the ACBMB may be configured to all directions above. Note that when using a neck reducer (ANAG) the configuration of the ACBMB must be carried out prior to fitting the neck reducer. The blade profiles have been designed to provide the most efficient operation at the lowest possible sound level. The main components of the grille are manufactured from extruded aluminium. Finish Standard finish is white electrostatic powdercoat. There are also 15 other colours available at no additional cost. Contact your local Bradflo branch for any special requirement you may have. Page. 28

CURVED BLADE REGISTER 1.41 ACB Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Throw is given for equal slots in each direction. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s Performance data (1-way blow) Static Pressure (Pa) 0 2 0 3 400 4 0 600 35 25 8-16 - 5 2-4 6-12 7-14 2 5-4 - 8 3-6 1 0 0 0 00 00 Performance data (2-way blow) Static Pressure (Pa) 0 2 0 3 400 4 0 600 35 25 6-12 7-14 5-5 4-8 2 3-6 2-4 1 0 0 0 00 00 These graphs are for selection only and should not be used for commissioning Page. 29

1.41 ACB CURVED BLADE REGISTER Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Throw is given for equal slots in each direction. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s Performance data (3-way blow) Static Pressure (Pa) 0 2 0 3 400 4 0 600 25 35 6-12 5-5 4-8 3-6 2 2-4 1 0 0 0 00 00 Performance data (4-way blow) Static Pressure (Pa) 0 2 0 3 400 4 0 600 35 25 5-5 4-8 3-6 2 2-4 1 0 0 0 00 These graphs are for selection only and should not be used for commissioning 00 Page.

CURVED BLADE REGISTER 1.41 ACB Air pattern configuration Sound data NR levels for the grille may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 All +16 +14 +12 +6-1 -6-8 Tol +/- 2 2 2 2 2 2 2 Correction factor K ok L w = NR + K ok Air pattern (with isothermal air supply) b h = L 0.3 x 0.03 L bh = L 0.3 x 0.5 b h b v = L 0.3 x 0.05 L bv = L 0.3 x 0.4 L bh b v L bv Page. 31

ACOUSTIC TRANSFER GRILLE 1.51 ATJ Sound Selection Chart Min 25 35 NR db Selection Guide l/s 770 X 1 9 X 1 770 X 180 9 X 180 Size 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..Y (X & Y are the nominal face sizes of the grille, see overleaf) Example: If your requirement is for a 31 x 7 (770 x 180) acoustic transfer grille, the ordering code would be ATJ37. {When ordering it is not necessary to include the periods [..]) "Type" "X" Size 05 (1) 07 (180) Product Size Numbers "Y" Size Colour ATJ 31 (770) Powder coat white 37 (9) Special colours Note! Shaded areas indicate standard product. Page. 32

1.51 ATJ ACOUSTIC TRANSFER GRILLE Description Finish The 1.51 (ATJ) grille is a rectangular air transfer device for mounting directly on walls. The grille is double sided and identical both sides. The construction allows a very small sound transmition area in relation to the air flow. This results in neglible deterioration of the wall s original sound reduction factor. The grille may be used regardless of the wall thickness Standard finish is white electrostatic powdercoat. There are also 15 other colours to choose from at no additional cost. Contact your local Bradflo branch for any special requirement you may have. Design dimensions Size X Y L S 1 kg A 770 1 700 0.03 3.0 B 9 1 800 0.04 3.6 C 770 180 700 0.0400 3.2 D 9 180 800 0.00 3.8 Net reduction loss (S 1 =transmissionarea) Page. 33

ACOUSTIC TRANSFER GRILLE 1.51 ATJ Sound data Performance graph NR levels for the grille may be determined from the engineering graph. 2 Static Pressure (Pa) Size A B Sound power level L w C The generated sound power level L w db is calculat- 0 40 D ed by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: 35 L w = NR + K ok 25 Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 All +5 +7 +2-2 -7-21 -21 Tol +/- 2 2 2 2 2 2 2 Correction factor k ok 5 0 0 0 Table 1 shows the reduction factors R 1 and the mean reduction factor R 1 m relative to the transmission area S 1 of the air transfer grille. Size R 1 R 1m Mid band frequency in Hz 125 2 0 00 00 A&C 11 15 22 23 39 22 B & D 11 14 21 23 40 22 Table 2 shows the reduction factors R 2 and the mean reduction factor R 2m and the Ia value relative to the transmission area of 2m 2. Size R 1 R 1m I a Mid band frequency in Hz 125 2 0 00 00 A & C 11 15 22 23 39 22 37 B & D 11 14 21 23 40 22 35 Sound measurements are carried out in accordance with the ISO-Standard 3741 method 2 and ASHRAE 36-72 These graphs are for selection only and should not be used for commissioning. Page. 34

ALUMINIUM DOOR REGISTER 1.52 AADR Selection Guide Sound Selection Chart Min 25 35 NR db l/s 1 2 2 3 4 6 Size 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..Y (X & Y are the nominal neck sizes of the register, see over leaf) Example: If your requirement is for a 24 x 12 (600 x 0) aluminium door register, the ordering code would be AADR2412. {When ordering it is not necessary to include the periods [..]) "Type" "X" Size 06 (1) 08 (0) Product Size Numbers (2) 12 (0) "Y" Size 16 (400) 18 (4) (0) 22 (5) 24 (600) Colour AADR 12 (0) 18 (4) 24 (600) Natural Anodised Special sizes Page. 35

1.52 AADR ALUMINIUM DOOR REGISTER Description Finish The 1.52 (AADR) door registers have horizontally mounted blades firmly fixed into a frame. To ensure a pleasing appearance an adjustable rear frame covers the opening on the opposite side of the door. A unique spring clip method eliminates the need for screws of any sort when fixing the register to the door. All registers are manufactured from natural anodised aluminium extrusion and will fit doors from mm to 45mm thick. The blade profiles ensure maximum air flows at minimum sound levels. Standard finish is natural anodised. There are also 15 other colours to choose from at no additional cost. Contact your local Bradflo branch for any special requirement you may have. Design dimensions Design dimensions Page. 36

ALUMINIUM DOOR REGISTER 1.52 AADR Installation Sound data NR levels for the grille may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: L w = NR + K ok Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 All +15 +14 +12 +7 +1-4 -6 Tol +/- 2 2 2 2 2 2 2 Correction factor K ok Free Area Factor To calculate the free area, the grilles nominal area is multiplied by f 1 where f 1 is a correction factor and is determined by the graph below. The free area of standard sizes may be found adjacent. Opening Size Free Area 600 x 1 0.062 600 x 2 0.093 600 x 2 0.114 600 x 3 0.145 600 x 4 0.216 600 x 6 0.0 Correction Factor 0.85 0.8 0.75 0.7 0.65 0.6 0 0 0 0 400 0 600 700 Nominal size Page. 37

1.52 AADR ALUMINIUM DOOR REGISTER Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Other terminal velocities may be calculated using formulas in Section 4.2 of the Air Handling Reference Guide. Throw is given for equal slots in each direction. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s Performance data 0 Static Pressure (Pa) 1 2 2 3 4 6 40 35 25 5 1 0 0 0 00 00 These graphs are for selection only and should not be used for commissioning. Page. 38

WEATHER LOUVRE 1.61 AWL Selection Guide Sound Selection Chart Min 35 40 45 NR db l/s 0. 0. 0. Size m 2 1.00 2.00 4.00 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..Y (X & Y are the nominal neck sizes of the louvre, see overleaf.) Example: If your requirement is for a 24 x 12 (600 x 0) weather louvre, the ordering code would be AWLF2412. {When ordering it is not necessary to include the periods [..]) "Type" "X" Size 06 (1) 08 (0) Product Size Numbers (2) 12 (0) "Y" Size 16 (400) 18 (4) (0) 24 (600) Colour AWLF (standard) 06 (1) AWLC (recessed) 08 (0) (2) Natural anodised Special sizes 12 (0) 16 (400) 18 (4) (0) 24 (600) Special colours Page. 39

1.61 AWL WEATHER LOUVRE Description The 1.61 weather louvre has been designed to ensure minimum ingress of water whilst maintaining maximum air flow at low noise levels. The weather louvre may be used for supply or exhaust applications. Standard weather louvre s are manufactured with either flanged frame for surface mounting or channel frame for recess mounting. Blades and frames are manufactured from extruded aluminium. Finish Standard finish is natural anodised. There are 15 other colours available. Contact your local Bradflo branch for any special requirement you may have. Design and mm dimensions Most sizes can be manufactured, however, contact your nearest Bradflo branch with your special sizes. Bird wire is fitted to the rear of the weather louvre as standard. Design dimensions (flanged frame) Design dimensions (recessed frame) Page. 40

WEATHER LOUVRE 1.61 AWL Free Area Factor 0.8 Correction Factor To calculate the free area the louvre s nominal area is multiplied by f 1 where f 1 is a 0.7 correction factor and is determined by the graph. 0.6 0.5 0.4 0.3 0 0 0 0 400 0 600 700 800 900 00 10 10 1400 10 Nominal "Y" size Performance graph 1 0 Static Pressure (Pa) 40 35 25 45 0.1 0.2 0.3 0.5 0.75 1.0 1.5 2.0 3.0 4.0 1 0 0 00 00 000 These graphs are for selection only and should not be used for commissioning. Page. 41

VERTICAL WEATHER LOUVRE 1.62 AWLV Selection Guide Sound Selection Chart Min 35 40 45 NR db l/s 0. 0. 0. Size m 2 1.00 2.00 4.00 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..Y (X & Y are the nominal neck sizes of the louvre, see overleaf) Example: If your requirement is for a 24 x 12 (600 x 0) face mounted vertical weather louvre, the ordering code would be AWLV2412. {When ordering it is not necessary to include the periods [..]) "Type" "X" Size 06 (1) 08 (0) Product Size Numbers (2) 12 (0) "Y" Size 16 (400) 18 (4) (0) 24 (600) Colour AWLV (standard) 06 (1) AWLVC (recessed) 08 (0) Standard Special sizes (2) Natural anodised 12 (0) 16 (400) 18 (4) (0) 24 (600) Special colours Page. 42

1.62 AWLV VERTICAL WEATHER LOUVRE Description The 1.62 vertical weather louvre has been designed to ensure minimum ingress of water whilst maintaining maximum air flow at low noise levels. The weather louvre may be used for supply or exhaust applications where vertical blades are a requirement.. Standard weather louvre s are manufactured with either flanged frame for surface mounting or channel frame for recess mounting. Blades and frames are manufactured from extruded aluminium. Finish Standard finish is natural anodised. There are 15 other colours available. Contact your local Bradflo branch for any special requirement you may have. Design and mm dimensions Most sizes can be manufactured, however, contact your nearest Bradflo branch with your special sizes. Bird wire is fitted to the rear of the weather louvre as standard. Design dimensions (flanged frame) Design dimensions (recessed frame) Page. 43

VERTICAL WEATHER LOUVRE 1.62 AWLV Free Area Factor 0.8 Correction Factor To calculate the free area the louvre s nominal area is multiplied by f 1 where f 1 is a 0.7 correction factor and is determined by the graph. 0.6 0.5 0.4 0.3 0 0 0 0 400 0 600 700 800 900 00 10 10 1400 10 Nominal "Y" size Performance graph 1 0 Static Pressure (Pa) 25 40 35 45 0.1 0.2 0.3 0.5 0.75 1.0 1.5 2.0 3.0 4.0 5.0 1 0 0 0 00 00 00 000 These graphs are for selection and should not be used for commissioning. Page. 44

DOUBLE TRAP WEATHER LOUVRE 1.63 AWLD Selection Guide Sound Selection Chart Min 35 40 45 NR db l/s 0. 0. 0. Size m 2 1.00 2.00 4.00 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..Y (X & Y are the nominal neck sizes of the louvre, see overleaf.) Example: If your requirement is for a 24 x 12 (600 x 0) face mounted weather louvre, the ordering code would be AWLD2412. {When ordering it is not necessary to include the periods [..]) "Type" "X" Size 06 (1) 08 (0) Product Size Numbers (2) 12 (0) "Y" Size 16 (400) 18 (4) (0) 24 (600) Colour AWLD (standard) 06 (1) AWLDC (recessed) 08 (0) Standard Special sizes (2) Natural anodised 12 (0) 16 (400) 18 (4) (0) 24 (600) Special colours Page. 45

1.63 AWLD DOUBLE TRAP WEATHER LOUVRE Description The 1.63 double trap weather louvre has been designed to ensure minimum ingress of water whilst maintaining maximum air flow at low noise levels. The weather louvre may be used for supply or exhaust applications. Standard weather louvre s are manufactured with either flanged frame for surface mounting or channel frame for recess mounting. Blades and frames are manufactured from extruded aluminium. Finish Standard finish is natural anodised. There are also 15 other colours to choose from. Contact your local Bradflo branch for any special requirement you may have. Design and mm dimensions Most sizes can be manufactured, however, contact your nearest Bradflo branch with your special sizes. Bird wire is fitted to the rear of the weather louvre as standard. Design dimensions (flanged frame) Design dimensions (recessed frame) Page. 46

DOUBLE TRAP WEATHER LOUVRE 1.63 AWLD Free Area Factor 0.8 Correction Factor To calculate the free area the louvre s nominal area is multiplied by f 1 where f 1 is a 0.7 correction factor and is determined by the graph. 0.6 0.5 0.4 0.3 0 0 0 0 400 0 600 700 800 900 00 10 10 1400 10 Nominal "Y" size Performance graph 1 0 Static Pressure (Pa) 25 35 40 0.1 0.2 0.3 0.5 0.75 1.0 1.5 2.0 3.0 45 4.0 5.0 1 0 0 00 00 000 The graphs are for selection only and should not be used for commissioning. Note The Double Rain Trap Weather Louvre water is resistant except where the airflow exceeds the limits shown below. Over 2.25m/s some water vapour may be carried over. Over 3.m/s droplets formed on blades may be carried over. Over 4.25m/s the grille is no longer considered to be water resistant. Page. 47

SLIMLINE WEATHER LOUVRE 1.64 AWLS Selection Guide Sound Selection Chart Min 35 40 45 NR db l/s 0. 0. 0. Size m 2 1.00 2.00 4.00 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..Y (X & Y are the nominal neck sizes of the louvre, see overleaf.) Example: If your requirement is for a 24 x 12 (600 x 0) slimline flange mounted weather louvre, the ordering code would be AWLSF2412. {When ordering it is not necessary to include the periods [..]) "Type" "X" Size 06 (1) 08 (0) Product Size Numbers (2) 12 (0) "Y" Size 16 (400) 18 (4) (0) 24 (600) Colour AWLSF 06 (1) 08 (0) Standard Special sizes (2) Natural anodised 12 (0) 16 (400) 18 (4) (0) 24 (600) Special colours Page. 48

1.64 AWLS SLIMLINE WEATHER LOUVRE Description The 1.64 slimline weather louvre has been designed to ensure a low ingress of water whilst maintaining maximum air flow at low noise levels. The weather louvre may be used for supply or exhaust applications. Standard weather louvre s are manufactured with either flanged frame for surface mounting or channel frame for recess mounting. Blades and frames are manufactured from extruded aluminium. Finish Standard finish is natural anodised. There are also 15 other colours to choose from. Contact your local Bradflo branch for any special requirement you may have. Design and mm dimensions Most sizes can be manufactured, however, contact your nearest Bradflo branch with your special sizes. Bird wire is fitted to the rear of the weather louvre as standard. Design dimensions (flanged frame) These graphs are for selection only and should not be used for commissioning. 0.8 Correction Factor 0.75 0.7 0.65 0.6 0.55 0.5 0 0 0 0 400 0 600 700 800 900 00 10 Nominal "Y" size To calculate the free area, the louvre s nominal area is multiplied by f 1 where f 1 is a correction factor and is determined by the graph above. Page. 49

HOME DIFFUSERS 1 GRILLES & LOUVRES 2 DIFFUSERS Chapter Description Product Code 2.12 A-Blade linear diffuser ALDA 2.13 Plenum diffuser AVPA 2.21 Single air boot AABS 2.22 Double air boot AABD 2.31 Directional diffuser ACT 2.35 Directional diffuser ACB 2.36 Directional diffuser ACTL 2.37 Directional diffuser ACTB 2.41 Circulate plate diffuser ACDSC 2.42 Circular cone diffuser ACDRA 2.43 Round ceiling diffuser ARCD 2.51 Jet diffuser AJD 2.52 Jet diffuser AJA 2.53 Jet diffuser AJS 2.61 Perforated diffuser APD 2.62 Perforated exhaust grille APDE 2.63 Perforated Circular diffuser APR 2.64 Environment 00 exhaust grille APME 2.65 Environment 00 diffuser APMF 2.66 Environment 00 diffuser with plenum APM 3 PLENUMS 4 FITTINGS & ACCESSORIES Dampers, Equalisers & Measures 5 FLEXIBLE DUCTING

A-BLADE LINEAR DIFFUSER 2.12 ALDA Sound Selection Chart Min 25 35 NR db Selection Guide 1 slot x 00 2 slot x 00 3 slot x 00 Size Horizontal 1 - way MAX Recommended l/s 4 slot x 00 Δ T = 12 o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..S (X & Y are the nominal neck sizes of the diffuser, see overleaf.) For corners the ordering code is Type..S. Example: If your requirement is for a 2 slot linear diffuser with one end and mm long, the ordering code would be ALDA1E482. {When ordering it is not necessary to include the periods [..]). For a 2 slot 90 o corner the ordering code would be ALDA902. Note! Other sizes are available. Please contact your nearest Bradflo office. Product Size Numbers Number of slots, "S" "Type" "X" Size 1 2 3 4 5 6 7 8 Colour ALDA2E (2 ends) 24 (600) Powder coat white ALDA1E (1 end) 36 (900) Black internal blades ALDA0E (0 ends) 48 () ALDAC90 (90 0 corner) 72 (1800) 8 (2700) ALDAC135 (135 0 corner) Special sizes Special colours Page. 6

2.12 ALDA A-BLADE LINEAR DIFFUSER Description Finish The 2.12 (ALDA) linear diffuser is a versatile product designed for supply, return or exhaust air systems. The design incorporates concealed aligning keyways for continuous application. Center T-rails are easily removed to simplify installation. The blades are adjustable to facilitate an air pattern through 180 o. Maximum length of each individual piece is 2700mm. Please discuss your requirement with your nearest Bradflo office. Standard finish is natural anodised or white electrostatic powdercoat. There are also 15 other colours to choose from at no additional cost. Contact your local Bradflo branch for any special requirement you may have. Design dimensions Slot A B C D 1 40 53 77 2 78 53 115 88 3 116 53 153 126 4 154 53 192 164 5 192 53 2 2 6 2 53 268 240 7 269 53 6 279 8 7 53 344 317 Page. 7

A-BLADE LINEAR DIFFUSER 2.12 ALDA Sound data NR levels for the grille may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: Air pattern (with isothermal air supply) b h = L 0.3 x 0.02 + length L bh = L 0.3 x 0.7 b v = L 0.3 x 0.07 L bv = L 0.3 x 0.6 L w = NR + K ok Frequency (cycles per second) No. Slots 125 2 0 00 00 4000 8000 1 +22 +12 + +6 +5-2 -6 2 +23 +14 + +6 +5-2 -6 3 + +15 + +6 +5-1 -6 4 +21 +14 + +6 +5 0-7 6 +21 +14 + +6 +5 0-7 8 + +14 + +6 +5-5 -6 Tol +/- 2 2 2 2 2 2 2 Correction factor K ok L bh b h Data shown in engineering graphs is for lengths of 00 mm. For other lengths, refer to the correction tables below. L bv b v Correction tables Diffuser length (m) 0.5 1 1.5 2 3 AddtoNRvalue -3 0 +2 +3 +5 Multiply throw by 0.7 1 1.25 1.4 1.55 Horizontal pattern Model 2.12 is a diffuser which provides variable air flow pattern controls by means of individually operated blades. This type of control does afford some degree of volume adjustment. The design of the blades is such that noise generation is kept to a minimum. Diffuser length (m) 0.5 1 1.5 2 3 AddtoNRvalue -3 0 +2 +3 +5 Multiply throw by 0.7 1 1.2 1.4 1.5 Vertical pattern Diffuser length (m) 0.5 1 1.5 2 3 AddtoNRvalue -3 0 +2 +3 +5 Return air Page. 8

2.12 ALDA A-BLADE LINEAR DIFFUSER Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Throw is given for equal slots in each direction. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. ALDA horizontal 1-way pattern 2 Static Pressure (Pa) (No. Slots x 00mm) Refer to correction tables for other lengths. 1 2 3 4 0 40 35 6-12 5-25 4-8 2.5-5 3-6 5 2-4 0 0 0 00 ALDA horizontal 2-way pattern (No. Slots x 00mm) Refer to correction tables for other lengths. 2 Static Pressure (Pa) 2 4 6 8 0 40 35 6-12 5-25 2.5-5 3-6 4-8 2-4 5 0 0 00 00 Page. 9

A-BLADE LINEAR DIFFUSER 2.12 ALDA Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Throw is given for equal slots in each direction. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. ALDA vertical projection (No. Slots x 00mm) Refer to correction tables for other lengths. 2 Static Pressure (Pa) 1 2 3 4 5 6 7 8 0 40 35 25 8-12 7-11 6-5 - 8 9-14 5 4-6.5 3-5 2-3.5 1 0 0 00 00 ALDA return air (No. Slots x 00mm) Refer to correction tables for other lengths. 0 Static Pressure (Pa) 1 2 3 4 5 6 7 8 40 35 5 25 1 0 0 0 00 Page.

PLENUM DIFFUSER 2.13 AVPA Selection Guide Sound Selection Chart Min 25 35 NR db MAX Recommended l/s 1 slot x 600 1 slot x 900 1 slot x 2 slots x 600 2 slots x 900 2 slots x Size Horizontal 1 way blow Δ T = 12 o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..S..X..I (X is the overall length of the diffuser.) Example: If your requirement is for a 2 slot insulated plenum diffuser mm long with a 225 dia. inlet, the ordering code would be AVPAI24809. {When ordering it is not necessary to include the periods [..]). Note! Other sizes are available. Please contact your nearest Bradflo office. Product Size Numbers Number of slots "S" "Type" "X" Size 1 2 AVPA (uninsulated) 24 (600) AVPAI (insulated) 36 (900) 48 () 08 (0) Inlet diameter "I" 09 (225) (2) Colour Special lengths Page. 11

2.13 AVPA PLENUM DIFFUSER Description The 2.13 (AVPA) is a linear plenum diffuser designed to suit ceiling T-Bar systems. It has been designed specifically for perimeter air distribution systems although it can be used for other applications. Special consideration has been given to the various T-Bar ceiling systems in common use. The 2.13 is compatible with T-Bar face sizes from 25 to mm. The insulation is 25mm thick glasswool with the ends uninsulated. Other types of insulation are available Design dimensions The 2.13 diffusers are designed to handle maximum air quantities at the lowest practicable sound levels and are available in either one or two slot configurations. All diffusers are manufactured from galvanised steel and aluminium. The blade position is adjustable through the face of the diffuser. Finish All visible surfaces in situ are painted black. AVPAI Insulated Page. 12

PLENUM DIFFUSER 2.13 AVPA Design Dimensions AVPA Non Insulated Standard sizes available. Slots Size Overall Inlet B Length Diameter 1 600-0 600 2 0 1 900-0 900 2 0 1 900-225 900 275 225 1-0 1190 2 0 1-225 1190 275 225 1-2 1190 0 2 2 600-0 600 2 0 2 900-0 900 2 0 2 900-225 900 275 225 2-0 1190 2 0 2-225 1190 275 225 2-2 1190 0 2 Page. 13

2.13 AVPA PLENUM DIFFUSER Sound data Air pattern NR levels for the grille may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: (with isothermal air supply) b h = L 0.3 x 0.02 + length L bh = L 0.3 x 0.6 b v = L 0.3 x 0.08 L bv = L 0.3 x 0.5 L w = NR + K ok Frequency (cycles per second) No. Slots 125 2 0 00 00 4000 8000 1 +14 +16 +11 +6 +5 0 0 2 +15 +12 +8 +6 +5-5 -21 Tol +/- 2 2 2 2 2 2 2 b h Correction factor K ok L bh Sound absorption ΔL db The sound absorption shown relates to a reduction of the sound power level calculated from duct to room. The orifice loss is included in the values. L bv b v Frequency (cycles per second) No. Slots 125 2 0 00 00 4000 8000 1 14 9 9 15 15 15 14 2 14 9 13 7 11 Tol +/- 2 2 2 2 2 2 2 Page. 14

PLENUM DIFFUSER 2.13 AVPA Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s AVPA 2 Slots 1-way blow AVPA 2 Slots 2-way blow Static Pressure (Pa) 1 Size 600 900 Static Pressure (Pa) 1 Size 600 900 0 40 0 40 35 5-35 4-8 25 4-8 25 3-6 3-6 2.5-5 2-4 2.5-5 2-4 1.5-3 5 5 1 0 1 1 0 1 These graphs are for selection only and should not be used for commissioning. AVPA 1 Slots 1-way blow Static Pressure (Pa) 2 Size 600 900 0 40 5-25 35 4-8 3.5-7 3-6 2.5-5 2-4 5 0 0 Page. 15

SINGLE AIR BOOT 2.21 AABS Sound Selection Chart Selection Guide AABS TYPE A Size Min 25 35 NR db MAX Recommended AABS TYPE B AABS TYPE C l/s Δ T = 12 o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..I (X is the overall length of the air boot). Example: If your requirement is for a mm long diffuser with a 0 dia. inlet, to suit a 12mm slot 90 o blow, the ordering code would be AABSB4808. {When ordering it is not necessary to include the periods [..]). Note! Other sizes are available. Please contact your nearest Bradflo office. "Type" "X" Size AABSA (single mm slot) 24 (600) AABSB (single 12mm slot) 36 (900) 05 (125) Product Size Numbers Inlet diameter "I" 06 (1) 07 (175) 08 (0) (2) Colour AABSC (single mm 180 o deflection) 48 () Special lengths Page. 16

2.21 AABS SINGLE AIR BOOT Description The 2.21 (AABS) diffusers are designed to be fitted to recessed fluorescent light fittings. They may also be used in conjunction with a ceiling T-Bar system. Full details of the light fittings must be provide to ensure the correct interface of the light with the air boot. This is essential to ensure optimum air distribution performance is obtained from the combination. Insulated versions of the diffuser plenum are not insulated at the ends. All diffusers are manufactured from galvanised sheet steel and aluminium blades which may be adjusted via the outlet slot. Australian standard The 2.21 diffuser complies with the requirements of the Australian Standard AS 2946-1987 Finish All visible surfaces are painted flat black. Three basic types of blade and slot width provide air flow direction of 90 o up to 180 o. Design dimensions Type A - single side - mm slot - 0 to 90 o air deflection Type B - single side - 12 mm slot - 0 to 90 o air deflection Type C - single side - mm slot - 0 to 180 o air deflection Page. 17

SINGLE AIR BOOT 2.21 AABS Sound data NR levels for the grille may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: Air pattern (with isothermal air supply) b h = L 0.3 x 0.02 + length L bh = L 0.3 x 0.6 b v = L 0.3 x 0.08 L bv = L 0.3 x 0.5 L w = NR + K ok Frequency (cycles per second) Hz Size 125 2 0 00 00 4000 8000 A- Single B- Single +9 +14 +12 +3 +3-9 -28 +13 + +9-1 -2-18 -22 b h C- Single +13 + +9-1 -2-18 -22 Tol +/- 2 2 2 2 2 2 2 L bh Correction factor K ok b v Sound absorption ΔL db L bv The sound absorption shown relates to a reduction of the sound power level calculated from duct to room. The end reflection is included in the values. Frequency (cycles per second) Hz Size 125 2 0 00 00 4000 8000 8 A- Single B- Single C- Single 13 9 4 0 0 0 0 14 5 1 0 0 0 14 5 1 0 0 0 Tol +/- 2 2 2 2 2 2 2 5 140 Dimensions for the keyhole slot for fitting. Page. 18

2.21 AABS SINGLE AIR BOOT Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s AABD Type A AABD Type B Static Pressure (Pa) 2 mm Slot x mm Static Pressure (Pa) 2 12mm Slot x mm 0 35 40 3-6 2.5-5 0 25 40 2.5-5 35 2-4 1.5-3 1-2 25 2-4 1.5-3 5 5 1 0 0 1 0 These graphs are for selection only and should not be used for commissioning. AABD Type C Static Pressure (Pa) 2 mm Slot x mm 0 35 40 3-6 2.5-5 2-4 25 1.5-3 5 1 0 0 Page. 19

DOUBLE AIR BOOT 2.22 AABD Sound Selection Chart Selection Guide AABS TYPE A Size Min 25 35 NR db MAX Recommended AABS TYPE B AABS TYPE C l/s Δ T = 12 o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..I + (the distance between the two inside faces of the diffuser, to suit the luminaire) (X is the overall length of the diffuser). Example: If your requirement is for a mm long diffuser with a 0 dia. inlet, 12mm slot 90 0 blow with 0 mm between the diffusers, the ordering code would be AABDB4808 + 0. {When ordering it is not necessary to include the periods [..]). Note! Other sizes are available. Please contact your nearest Bradflo office. "Type" "X" Size AABDA (single mm slot) 24 (600) AABDB(single 12mm slot) 36 (900) AABDC (single mm 180 o deflection) 48 () 05 (125) Product Size Numbers Inlet diameter "I" 06 (1) 07 (175) 08 (0) (2) Colour Special lengths Page.

2.22 AABD DOUBLE AIR BOOT Description The 2.22 (AABD) diffusers are designed to be fitted to recessed fluorescent light fittings. They may also be used in conjunction with a ceiling T-Bar system. Full details of the light fittings must be provided to ensure the correct interface of the light with the air boot. This is essential to ensure optimum air distribution performance is obtained from the combination. Insulated versions of the diffuser plenum are not insulated at the ends. All diffusers are manufactured from galvanised sheet steel and aluminium blades which may be adjusted via the outlet slot. Australian standard The 2.22 diffuser complies with the requirements of the Australian Standard AS 2946-1987 Finish All visible surfaces are painted flat black. Three basic types of blade and slot width provide air flow direction of 90 o up to 180 o. Type A - double sided - mm slot -0 to 90 o deflection Type B - double sided - 12 mm slot -0 to 90 o deflection Type C - double sided - mm slot -0 to 180 o deflection Note! These sizes are available as standard products. Variations are available upon request. Contact Bradflo with your specific requirements. Page. 21

DOUBLE AIR BOOT 2.22 AABD Sound data NR levels for the grille may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: Air pattern (with isothermal air supply) b h = L 0.3 x 0.02 + length L bh = L 0.3 x 0.6 b v = L 0.3 x 0.08 L bv = L 0.3 x 0.5 L w = NR + K ok Frequency (cycles per second) No. Slots 125 2 0 00 00 4000 8000 A Double + +15 +12 +1-1 -16-25 B Double + +7 +7 _8-2 -15-26 C Double +14 +17 +9 +5-2 -16-27 Tol +/- 2 2 2 2 2 2 2 Correction factor K ok L bh b h b v Sound absorption ΔL db The sound absorption shown relates to a reduction of the sound power level calculated from duct to room. The end reflection is included in the values. L bv Frequency (cycles per second) No. Slots 125 2 0 00 00 4000 8000 A Double 13 9 4 0 0 0 0 B Double 13 9 4 0 0 0 0 C Double 13 9 4 0 0 0 0 Tol +/- 2 2 2 2 2 2 2 Page. 22

2.22 AABD DOUBLE AIR BOOT Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s AABD Type A AABD Type B Static Pressure (Pa) 2 mm Slot x mm Static Pressure (Pa) 2 12mm Slot x mm 0 0 40 35 2.5-5 25 40 3-6 35 2.5-5 2-4 1.5-3 2-4 25 1.5-3 1-2 0.5-1 5 5 1 1 0 0 0 0 0 These graphs are for selection only and should not be used for commissioning. AABD Type C Static Pressure (Pa) 2 mm Slot x mm 0 40 3-6 35 2.5-5 2-4 25 1.5-3 5 1 0 0 0 Page. 23

DIRECTIONAL DIFFUSER 2.31 ACT Selection Guide Sound Selection Chart Min 25 35 NR db MAX Recommended l/s 1 225 0 375 4 525 600 Size Δ T = 12 o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. ACT..T..B..X..Y (X & Y are the nominal neck sizes of the diffuser, see overleaf.) Example: If your requirement is for a 12 x 12 (0mm x 0mm) 2 Way Corner blow diffuser, the ordering code would be ACT2C1212. {When ordering it is not necessary to include the periods [..]) Product Size Numbers "Y" Size "T" Type "B" "X" Size 06 09 12 15 18 21 24 Colour 1 1 Way blow W 06 (1) Powdercoat White 2 2 Way blow W 09 (225) 2 2 Way corner blow C 12 (0) 3 3 Way blow W 15 (375 4 4 Way blow W 18 (4) 21 (525) Special blow 24 (600) Special colours Page. 24

2.31 ACT DIRECTIONAL DIFFUSER Description The 2.31 (ACT) square cone type directional diffuser is all aluminium construction and has been designed to meet modern building requirements. Standard frame configurations are available which are suitable for T-bar, tile or plaster ceilings. To maximize versatility, the 2.31 series diffusers allow different blow patterns. As with all Bradflo air products, this diffuser offers maximum air flow characteristics whilst maintaining low noise levels. Finish The standard finish is powdercoat white, baked at a temperature of 180 deg. C. There are fifteen other standard colours available. Other colours are available as specials upon request. The core section is removable for easy installation and maintenance. Note! Blanking plates are available for all diffuser types as a special order. Refer to following pages for performance data. Type 1 Type 2 Type 2C Type 3 Type 4 Page. 25

DIRECTIONAL DIFFUSER 2.31 ACT Sound data NR levels for the grille may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: Air pattern (with isothermal air supply) b h = L 0.3 x 0.03 L bh = L 0.3 x 0.65 b v = L 0.3 x 0.06 L bv = L 0.3 x 0.65 L w = NR + K ok Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 1 +17 +13 + +8 +3-5 -15 225 +14 +11 + +8 +1 - -16 0 +13 +9 +9 +8-3 -15-18 4 +13 +9 +11 +7-6 -21-21 525 +12 +8 + +7-4 -23-24 600 +12 +7 +9 +7-4 -23-24 Tol +/- 2 2 2 2 2 2 2 Correction factor K ok L bh b v b h Sound absorption ΔL db The sound absorption shown relates to a reduction of the sound power level calculated from duct to room. The end reflection is included in the values. Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 1 14 5 1 0 0 0 225 13 9 4 0 0 0 0 0 6 2 0 0 0 0 4 9 5 1 0 0 0 0 525 7 3 1 0 0 0 0 600 6 3 1 0 0 0 0 Tol +/- 2 2 2 2 2 2 2 L bv Page. 26

2.31 ACT DIRECTIONAL DIFFUSER Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. The following graphs apply to all Bradflo Directional Diffusers in sections 2.31 to 2.37. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. 4-way pattern (square) 1 0 Static Pressure (Pa) 1 225 0 375 4 525 40 600 35 25 4.5-9 4-8 3.5-7 3-6 2.5-5 5 2-4 1.5-3 1-2 1 0 0 00 00 4-way pattern (square) blanked to 3-way blow 1 0 Static Pressure (Pa) 1 225 0 375 4 525 600 40 35 25 4-8 4.5-9 3.5-7 3-6 2.5-5 5 2-4 1.5-3 1-2 1 0 0 00 00 Page. 27

DIRECTIONAL DIFFUSER 2.31 ACT Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. The following graphs apply to all Bradflo Directional Diffusers in sections 2.31 to 2.37. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. 4-way pattern (square) blanked to a 2-way blow 1 0 Static Pressure (Pa) 25 1 225 0 375 4 525 40 35 4.5-9 4-8 600 3.5-7 3-6 2.5-5 5 1.5-3 2-4 1-2 1 0 0 0 00 4-way pattern (square) blanked to a 1-way blow 1 0 Static Pressure (Pa) 25 1 225 0 375 4 525 600 40 35 4.5-9 4-8 3.5-7 3-6 2.5-5 5 2-4 1.5-3 1-2 1 0 0 0 00 Page. 28

2.31 ACT DIRECTIONAL DIFFUSER Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. The following graphs apply to all Bradflo Directional Diffusers in sections 2.31 to 2.37. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. 4-way pattern (rectangular) 1 0 Static Pressure (Pa) 35 1x0 1x4 225x525 0x600 40 25 5-4.5-9 4-8 3.5-7 3-6 5 1.5-3 2-4 2.5-5 1 0 0 00 00 1-way pattern (square) 1 0 Static Pressure (Pa) 35 40 1 225 0 375 4 25 6-12 5-5 2-4 3-6 4-8 1 0 0 00 00 Page. 29

DIRECTIONAL DIFFUSER 2.31 ACT Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. The following graphs apply to all Bradflo Directional Diffusers in sections 2.31 to 2.37. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. 2-way pattern (square) 1 0 Static Pressure (Pa) 35 40 1 225 0 375 4 25 5-5 2-4 2.5-5 3-6 4-8 1 0 0 00 00 3-way pattern (square) 1 0 Static Pressure (Pa) 25 35 40 1 225 0 375 4 3.5-7 4.5-9 4-8 3-6 5 1-2 1.5-3 2-4 2.5-5 1 0 0 00 00 Page.

DIRECTIONAL DIFFUSER 2.35 ACB Selection Guide Sound Selection Chart Min 25 35 NR db MAX Recommended l/s 1 225 0 375 4 525 600 Size Δ T = 12 o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. ACB..T..B..X..Y (X & Y are the nominal neck sizes of the diffuser, see overleaf.) Example: If your requirement is for a 12 x 12 (0mm x 0mm) 2 Way Corner blow diffuser, the ordering code would be ACB2C1212. {When ordering it is not necessary to include the periods [..]) Product Size Numbers "Y" Size "T" Type "B" "X" Size 06 09 12 15 18 21 24 Colour 1 1 Way blow W 06 (1) Powdercoat White 2 2 Way blow W 09 (225) 2 2 Way corner blow C 12 (0) 3 3 Way blow W 15 (375 4 4 Way blow W 18 (4) 21 (525) Special blow 24 (600) Special colours Page. 31

2.35 ACB DIRECTIONAL DIFFUSER Description The 2.35 (ACB) square cone type directional diffuser is all aluminium construction and has been designed to meet modern building requirements. The standard bevel frame is suitable for tile or plaster ceilings. To maximise versatility, the 2.35 series diffuser offers a number of different blow patterns. As with all Bradflo air products, this diffuser offers maximum air flow characteristics whilst maintaining low noise levels. Finish The standard finish is powdercoat white, baked at a temperature of 180 deg. C. There are fifteen other standard colours available. Other colours are available as specials upon request. The core section is removable for easy installation and maintenance. Note! Blanking plates are available for all diffuser types as a special order. Refer to following pages for performance data. Type 1 Type 2 Type 2C Type 3 Type 4 Page. 32

DIRECTIONAL DIFFUSER 2.36 ACTL Selection Guide Sound Selection Chart Min 25 35 NR db MAX Recommended l/s 1 225 0 375 4 525 600 Size Δ T = 12 o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. ACTL..T..W..X..Y (X & Y are the nominal neck sizes of the diffuser, see overleaf.) Example: If your requirement is for a 12 x 12 (0mm x 0mm) 3 Way blow diffuser, the ordering code would be ACTL3W1212. {When ordering it is not necessary to include the periods [..]) Product Size Numbers "Y" Size "T" Type "X" Size 06 09 12 15 18 Colour 1 3 Way blow 06 (1) Powdercoat White 2 4 Way blow 09 (225) 12 (0) 15 (375 18 (4) Special blow Special colours Page. 33

2.36 ACTL DIRECTIONAL DIFFUSER Description The 2.36 (ACTL) square cone type directional diffuser has an aluminium frame and steel core construction. It has been designed to meet modern building requirements. Standard frame configurations are available which are suitable for T-bar, tile or plaster ceilings. To maximise versatility, the 2.36 series diffuser offers a number of different blow patterns. As with all Bradflo air products, this diffuser offers maximum air flow characteristics whilst maintaining low noise levels. Finish The standard finish is powdercoat white, baked at a temperature of 180 deg. C. There are fifteen other standard colours available. Other colours are available as specials upon request. The core section is removable for easy installation and maintenance. Note! Blanking plates are available for all diffuser types as a special order. Refer to following pages for performance data. Type 1 Type 2 Type 2C Type 3 Type 4 Page. 34

DIRECTIONAL DIFFUSER 2.36 ACTL Sound data NR levels for the grille may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: Air pattern (with isothermal air supply) b h = L 0.3 x 0.03 L bh = L 0.3 x 0.65 b v = L 0.3 x 0.06 L bv = L 0.3 x 0.65 L w = NR + K ok Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 1 +17 +13 + +8 +3-5 -15 225 +14 +11 + +8 +1 - -16 0 +13 +9 +9 +8-3 -15-18 4 +13 +9 +11 +7-6 -21-21 525 +12 +8 + +7-4 -23-24 600 +12 +7 +9 +7-4 -23-24 Tol +/- 2 2 2 2 2 2 2 Correction factor K ok L bh b h Sound absorption ΔL db The sound absorption shown relates to a reduction of the sound power level calculated from duct to room. The end reflection is included in the values. Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 1 14 5 1 0 0 0 225 13 9 4 0 0 0 0 0 6 2 0 0 0 0 4 9 5 1 0 0 0 0 525 7 3 1 0 0 0 0 600 6 3 1 0 0 0 0 Tol +/- 2 2 2 2 2 2 2 L bv b v Page. 35

2.36 ACTL DIRECTIONAL DIFFUSER Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. The following graphs apply to all Bradflo Directional Diffusers in sections 2.31 to 2.37. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. 4-way pattern (square) 1 0 Static Pressure (Pa) 1 225 0 375 4 525 40 600 35 25 4.5-9 4-8 3.5-7 3-6 2.5-5 5 2-4 1.5-3 1-2 1 0 0 00 00 4-way pattern (square) blanked to 3-way blow 1 0 Static Pressure (Pa) 1 225 0 375 4 525 600 40 35 25 4-8 4.5-9 3.5-7 3-6 2.5-5 5 2-4 1.5-3 1-2 1 0 0 00 00 Page. 36

DIRECTIONAL DIFFUSER 2.36 ACTL Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. The following graphs apply to all Bradflo Directional Diffusers in sections 2.31 to 2.37. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. 4-way pattern (square) blanked to a 2-way blow 1 0 Static Pressure (Pa) 25 1 225 0 375 4 525 40 35 4.5-9 4-8 600 3.5-7 3-6 2.5-5 5 1.5-3 2-4 1-2 1 0 0 0 00 4-way pattern (square) blanked to a 1-way blow 1 0 Static Pressure (Pa) 25 1 225 0 375 4 525 600 40 35 4.5-9 4-8 3.5-7 3-6 2.5-5 5 2-4 1.5-3 1-2 1 0 0 0 00 Page. 37

2.36 ACTL DIRECTIONAL DIFFUSER Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. The following graphs apply to all Bradflo Directional Diffusers in sections 2.31 to 2.37. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. 4-way pattern (rectangular) 1 0 Static Pressure (Pa) 35 1x0 1x4 225x525 0x600 40 25 5-4.5-9 4-8 3.5-7 3-6 5 1.5-3 2-4 2.5-5 1 0 0 00 00 1-way pattern (square) 1 0 Static Pressure (Pa) 35 40 1 225 0 375 4 25 6-12 5-5 2-4 3-6 4-8 1 0 0 00 00 Page. 38

DIRECTIONAL DIFFUSER 2.36 ACTL Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. The following graphs apply to all Bradflo Directional Diffusers in sections 2.31 to 2.37. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. 2-way pattern (square) 1 0 Static Pressure (Pa) 35 40 1 225 0 375 4 25 5-5 2-4 2.5-5 3-6 4-8 1 0 0 00 00 3-way pattern (square) 1 0 Static Pressure (Pa) 25 35 40 1 225 0 375 4 3.5-7 4.5-9 4-8 3-6 5 1-2 1.5-3 2-4 2.5-5 1 0 0 00 00 Page. 39

DIRECTIONAL DIFFUSER 2.37 ACTB Selection Guide Sound Selection Chart Min 25 35 NR db MAX Recommended l/s 1 225 0 375 4 525 600 Size Δ T = 12 o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. ACTB..T..W..X..Y (X & Y are the nominal neck sizes of the diffuser, see overleaf.) Example: If your requirement is for a 12 x 12 (0mm x 0mm) 4 Way blow diffuser, the ordering code would be ACTB4W1212. {When ordering it is not necessary to include the periods [..]) Product Size Numbers "Y" Size "T" Type "X" Size 06 09 12 15 18 Colour 1 3 Way blow 06 (1) Powdercoat White 2 4 Way blow 09 (225) 12 (0) 15 (375 18 (4) Special blow Special colours Page. 40

2.37 ACTB DIRECTIONAL DIFFUSER Description The 2.37 (ACTB) square cone type directional diffuser has an aluminium frame and steel core construction. It has been designed to meet modern building requirements. The standard bevel frame is suitable for tile or plaster ceilings. To maximise versatility, the 2.37 series diffuser offers a number of different blow patterns. As with all Bradflo air products, this diffuser offers maximum air flow characteristics whilst maintaining low noise levels. Finish The standard finish is powdercoat white, baked at a temperature of 180 deg. C. There are fifteen other standard colours available. Other colours are available as specials upon request. The core section is removable for easy installation and maintenance. Note! Blanking plates are available for all diffuser types as a special order. Refer to following pages for performance data. Type 1 Type 2 Type 2C Type 3 Type 4 Page. 41

CIRCULAR PLATE DIFFUSER 2.41 ACDSC Selection Guide Sound Selection Chart Min 25 35 NR db MAX Recommended l/s 125 Size 160 Inlet Diameter 0 2 315 400 Δ T = o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X (X is the nominal neck diameter of the diffuser). Example: If your requirement is for a 0 mm diameter ceiling diffuser, the ordering code would be ACDSC0 {When ordering it is not necessary to include the periods [..]). Product Size Numbers "Type" "X" Size Colour ACDSC 125 Powder coat white 160 0 2 315 400 0 Special colours Page. 42

2.41 ACDSC CIRCULAR PLATE DIFFUSER Description Finish The 2.41 (ACDSC) diffuser is a adjustable single cone diffuser which allows a horizontal pattern. The core of the diffuser is easily removed for fitting and cleaning. The diffuser may be ceiling mounted or mounted in exposed duct work. Standard construction is steel. Standard finish is white powder coated paint applied to a pre-treated surface and baked at 180 o C to ensure a tough surface that resists damage, fading and discolouration. Special colours are available. Contact your nearest Bradflo office with your requirements. Design dimensions X Size Dia. B Dia. C D 125 270 5 90 160 270 5 80 0 3 378 92 2 4 477 7 315 5 591 126 400 6 703 138 Page. 43

CIRCULAR PLATE DIFFUSER 2.41 ACDSC Sound data NR levels for the grille may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: Air pattern (with isothermal air supply) b v = L 0.3 x 0.06 L bv = L 0.3 x 0.65 L w = NR + K ok Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 125 +23 +17 +11 +5-1 -17-18 160 +24 +16 + +5 0-8 - 0 +23 +17 +9 +4 0-14 -15 2 +22 +15 +9 +1-1 -17-315 +23 +16 + -2-3 -15-15 400 +21 +16 +12-3 -9-8 -15 Tol +/- 2 2 2 2 2 2 2 L bv b v Correction factor K ok Sound absorption ΔL db The sound absorption shown relates to a reduction of the sound power level calculated from duct to room. The end reflection is included in the values. Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 125 16 12 7 2 0 0 0 160 14 5 1 0 0 0 0 13 9 4 0 0 0 0 2 11 7 3 0 0 0 0 315 6 2 0 0 0 0 400 9 5 1 0 0 0 0 Tol +/- 2 2 2 2 2 2 2 Page. 44

2.41 ACDSC CIRCULAR PLATE DIFFUSER Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. ASC Horizontal blow 1 0 5 Static Pressure (Pa) 40 35 25 125 160 0 2 315 400 4-8 3-6 2.5-5 2-4 1.5-3 1 0 0 00 0 0 Page. 45

CIRCULAR CONE DIFFUSER 2.42 ACDRA Selection Guide Sound Selection Chart Min 25 35 NR db MAX Recommended l/s 125 Size 160 Inlet Diameter 0 2 315 400 Δ T = o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X (X is the nominal neck diameter of the diffuser). Example: If your requirement is for a 0 mm diameter ceiling diffuser, the ordering code would be ACDRA0 {When ordering it is not necessary to include the periods [..]). Product Size Numbers "Type" "X" Size Colour ACDRA 125 Powder coat white 160 0 2 315 400 0 Special colours Page. 46

2.42 ACDRA CIRCULAR CONE DIFFUSER Description Finish The 2.42 (ACDRA) diffuser is a adjustable multiple cone diffuser which provides a horizontal and vertical pattern. The core of the diffuser is easily removed for fitting and cleaning. The diffuser may be ceiling mounted or mounted in exposed duct work. Standard construction is steel. Standard finish is white powder coated paint applied to a pre-treated surface and baked at 180 o C to ensure a tough surface that resists damage, fading and discolouration. Special colours are available. Contact your nearest Bradflo office with your requirements. Design dimensions X Size Dia. B Dia. C D G H 125 270 5 90 13 160 270 5 80 13 0 3 378 92 14 13 2 4 477 7 17 16 315 5 591 126 400 6 703 138 24 24 0 780 845 1 Page. 47

CIRCULAR CONE DIFFUSER 2.42 ACDRA Sound data NR levels for the grille may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: Air pattern (with isothermal air supply) b v = L 0.3 x 0.06 L bv = L 0.3 x 0.65 L w = NR + K ok Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 125 +14 +12 +11 +8 +4-4 -8 160 +14 +16 +11 +8 +3-5 -9 0 +15 +13 +11 +6 +2-6 -8 2 +17 +16 +11 +6 +2-8 -8 315 +15 +15 +12-6 +1-8 -8 400 +18 +16 +13-6 +1-7 -9 Tol +/- 2 2 2 2 2 2 2 L bv b v Correction factor K ok Sound absorption ΔL db The sound absorption shown relates to a reduction of the sound power level calculated from duct to room. The end reflection is included in the values. Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 125 16 12 7 2 0 0 0 160 14 5 1 0 0 0 0 13 9 4 0 0 0 0 2 11 7 3 0 0 0 0 315 6 2 0 0 0 0 400 9 5 1 0 0 0 0 Tol +/- 2 2 2 2 2 2 2 Page. 48

2.42 ACDRA CIRCULAR CONE DIFFUSER Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. ARA Horizontal blow (dimension G) 1 Static Pressure (Pa) 125 160 0 2 315 400 0 0 40 25 35 4-8 3-6 2.5-5 2-4 5 1.5-3 1-2 0.5-1 1 0.75-1.5 0 0 00 00 ARA Vertical blow (dimension H) 1 Static Pressure (Pa) 125 160 0 2 315 400 0 35 25 40 0-16.5 9-15 8-13.5 7-12 6-5 5-8 4-7 3.5-6 3-5 1 2.5-4 0 0 0 00 Page. 49

ROUND CEILING DIFFUSER 2.43 ARCD Selection Guide Sound Selection Chart Min 25 35 1 0 Size Inlet Diameter NR db 2 MAX Recommended l/s 4 Δ T = o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X (X is the nominal neck diameter of the diffuser). Example: If your requirement is for a 0 mm diameter ceiling diffuser, the ordering code would be ARCD0 {When ordering it is not necessary to include the periods [..]). Product Size Numbers "Type" "X" Size Colour ARCD 1 Powder coat white 0 2 0 Special colours Page.

2.43 ARCD ROUND CEILING DIFFUSER Description The 2.43 (ARCD) Round ceiling diffuser is fabricated from spun aluminium. The diffuser has a round spigot to suit flexible duct. The core is adjustable and acts as both balancing damper and pattern control. The diffuser may be easily fixed into position using special fixing clips provided. Finish Standard finish is white electrostatic powdercoat. There are also 15 other colours available to choose from at no additional cost. Contact your nearest Bradflo office for any special requirement you may have. Design dimensions Product Code A B C ARCD1 1 3 145 ARCD0 0 360 165 ARCD2 2 4 175 ARCD0 0 460 190 Page. 51

ROUND CEILING DIFFUSER 2.43 ARCD PERFORMANCE DATA Note! Throw data is at a terminal velocity of 0.5m/s. Air supply is isothermal Inlet Diameter mm (in) Discharg egap mm(in) Airflow I/s (cfm) Statistic Pressure pa ( In H 2 O) Sound Power Level Octave band centre frequency (Hz) Throw m (ft) 63 125 2 0 00 00 4000 8000 1 40 (1.6) 40 (85) 5.5 (.022).92 (3.0) 45.0 46.0 45.0 45.0 42.0 34.5 26.5 28.5 (5.9) 32 (1.25) 7.5 (.0) 1.40 (4.6) 45.0 45.5 43.5 45.0 44.0 35.5 21.5 29.5 25 (1.0) 23 (0.90) 1.70 (5.60) 43.5 51.5 48.5 45.0 42.0 36.5.0 2.3 40 (1.6) 75 (158) 6.5 (0.26) 1.35 (4.4) 44.5 46.5 44.5 45.0 43.5 33.5 26.5 28.5 32 (1.25) 8.5 (0.34) 1.70 (5.6) 46.0 52.0.0.5 51.0 43.5 34.5 23.5 25 (1.0) 44 (.173) 2.03 (6.7) 47.0 54.0.5.0.5 39.5 31.5 29.5 40 (1.6) 0 (212) 7 (.028) 1.80 (5.9) 45.0 49.5 47.5 49.0 49.0 41.0 25.5 28.5 32 (1.25) 13 (.051) 2. (8.2) 47.0 52.0 49.0 51.0 51.5 44.5 34.5 23.5 25 (1.0) 63 (.248) 3.00 (9.8) 48.0 54.0 52.5.5 52.5 46.0 36.5 29.0 40 (1.6) 1 (318) 13 (.051) 2.15 (7.1) 29.5 55.5 54.0 56.5 58.0 52.5 44.5 33.5 32 (1.25) 25 (1.0) 40 (1.6) 0 (424) 21 (.083) 2.95 (9.7) 57.5 66.0 63.0 64.0 66.0 62.0 55.0.5 32 (1.25) (.118) 3.4 (11.2) 56.0 64.0 63.0 61.5 64.5 60.5 52.5 49.0 25 (1.0) 1 (.472) 3.8 (12.5) 51.5 63.0 63.5 61.0 60.5 58.5 51.5 44.5 0 40 (1.6) 75 (158) 16 (.063).95 (3.1) 42.0 45.0 40.5 35.5 31.5 22.5 17.5 22.0 (7.9) 32 (1.25) (.118) 1.5 (4.9) 42.0 45.0 42.5 36.0 32.0 24.5 17.5 23.0 25 (1.0) 75 (.295) 1.8 (5.9) 42.5 57.0 47.0 43.5 38.0 34.0 25.0 23.0 40 (1.6) 0 (212) 18 (.071) 1.75 (5.7) 41.5 44.5 41.0 36.0 32.0 23.0 17.5 22.5 32 (1.25) 55 (.217) 1.85 (6.1) 41.5 48.5 46.5 41.5 37.5 33.5 21.5 23.0 25 (1.0) 3 (.406) 2.0 (6.6) 42.0 49.5 49.5 47.5 43.0 40.0 33.5 22.5 40 (1.6) 1 (318) 35 (.138) 2.1 (6.9) 45.0 51.5 48.5 44.0 41.0 36.5 22.5 22.5 32 (1.25) 96 (.378) 2.2 (7.2) 44.0 54.0 53.5 49.0 45.5 41.5 21.5 37.0 25 (1.0) 170 (.669) 2.6 (8.5) 44.0 54.5 56.0 56.0 52.0 49.0 44.0 37.0 40 (1.6) 0 (424) 57 (.224) 2.4 (7.9) 48.0 58.0 55.0.5 48.0 45.0 34.5 29.0 32 (1.25) 180 (.709) 2.65 (8.7) 48.0 60.0 60.5 57.0 53.0 51.0 42.5 37.0 25 (1.0) 265 (1.04) 3.0 (9.8) 47.5 59.0 60.5 62.5 59.5 55.0 51.5 47.0 40 (1.6) 2 (5) 95 (.374) 3.1 (.2) 51.0 64.0 61.5 57.0 55.5 53.0 45.5 35.5 32 (1.25) 260 (1.02) 3.35 (11) 51.5 65.0 65.5 63.0 59.5 57.0 51.5 45.0 40 (1.6) 0 (636) 2 (.866) 3.75 (12.3) 55.5 67.5.6 65.0 60.0 58.5 55.5 48.5 37.5 32 (1.25) 0 (1.97) 3.9 (12.8) 53.0 64.5 65.0 69.5 65.5 64.0 59.0 55.5 2 40 (1.6) 0 (212) 12 (.047) 1.05 (3.4) 42.5 41.5 35.5 31.0 26.0 11.5 16.5 28.0 (9.8) 32 (1.25) 15 (.059) 1.35 (4.4) 42.5 41.5 37.0 32.0 26.5 15.5 17.5 27.5 25 (1.0) 40 (.157) 2.2 (7.2) 42.0 44.0 43.5 39.5 36.5.0 24.5 22.0 40 (1.6) 1 (138) 18 (.071) 1.65 (5.4) 43.0 41.5 38.5 34.0 29.5 16.0 17.5 27.5 32 (1.25) (.079) 1.85 (6.1) 44.0 45.0 40.5 34.5 32.0 29.5 17.5 28.5 25 (1.0) 73 (.287) 2.8 (9.2) 44.0.5 48.0 43.5 41.5 38.5 28.0 21.5 40 (1.6) 0 (424) 27 (.6) 1.8 (5.9) 45.0 47.5 43.0 39.5 36.0 25.5 17.5 27.5 32 (1.25) (.197) 2.35 (7.7) 45.0.5 46.0 41.5 39.0 32.5 17.5 28.5 25 (1.0) 1 (.433) 3.40 (11.2) 43.5 54.5 52.5 48.5 47.0 44.5 36.5 28.5 40 (1.6) 2 (3) 42 (.165) 2.85 (9.3) 48.0 53.5 49.5 44.5 42.5 36.5 17.5 27.5 32 (1.25) 65 (.256) 3.0 (9.8) 46.0 53.5 51.5 47.0 44.5 39.0 17.5 36.0 25 (1.0) 165 (.6) 3.8 (12.5) 47.0 57.0 59.5 55.0 52.5.5 45.5 35.5 40 (1.6) 0 (636) 60 (.236) 3.05 (.0) 51.5 59.0 53.5 49.0 47.0 42.5 32.0 27.5 Page. 52

JET DIFFUSER 2.51 AJD Selection Guide Sound Selection Chart Min 25 35 0 2 Size Inlet Diameter NR db 0 MAX Recommended l/s 375 Δ T = 12 o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..N (X is the nominal neck diameter of the diffuser). Example: If your requirement is for three 2 mm diameter Jet diffusers mounted on a plate, the ordering code would be AJD23. {When ordering it is not necessary to include the periods [..]). Product Size Numbers Diffusers mounted on plate "N" "Type" "X" Size 1 2 3 4 Colour AJD 0 Powder coat white 2 0 375 Special colours Page. 53

2.51 AJD JET DIFFUSER Description Finish The 2.51 (AJD) diffusers are designed for air conditioning or ventilating large areas such as sports centres, theatres, entertainment and industrial areas. The diffusers are able to operate at a high air throughput. By rotating the nozzle through 360 deg., the air pattern may be adjusted from a jet pattern to a diffused pattern. The diffuser core is manufactured from spun alluminium and the outer case is steel. The entire assembly is powder coated in a range of standard colours. Contact your nearest Bradflo Office with your requirement. Design dimensions No. of Jets 1 2 3 4 X-Size Dia. H L W W W W 0 280 225 280 5 760 00 2 3 265 3 6 9 0 380 0 380 7 60 1400 375 455 0 455 870 1285 1700 1 to 4 Jet Diffusers mounted. Page. 54

JET DIFFUSER 2.51 AJD Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. AJD Jet pattern 2 Static Pressure (Pa) 0 2 0 375 0 25 35 40 8-16 16-32 14-28 12-24 - 25 - - 40 18-36 6-12 5 4-8 1 0 0 0 00 00 AJD Diffused pattern 2 Static Pressure (Pa) 0 2 0 375 0 25 35 40 4-8 5-8 - 16 7-14 16-12 12-24 - 9-18 3-6 5 2-4 1 0 0 0 00 00 Page. 55

JET DIFFUSER 2.52 AJA Selection Guide Sound Selection Chart Min 25 35 0 2 Size Diameter NR db 315 MAX Recommended l/s 400 Δ T = 15 o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..N (X is the nominal neck diameter of the diffuser). Example: If your requirement is for three 2 mm diameter Jet diffusers mounted on a plate, the ordering code would be AJA23. {When ordering it is not necessary to include the periods [..]). Product Size Numbers Diffusers mounted on plate "N" "Type" "X" Size 1 2 3 4 Colour AJA 0 Powder coat white AJAX 2 315 400 0 Special colours Page. 56

2.52 AJA JET DIFFUSER Description Finish The 2.52 (AJA) diffusers are designed for air conditioning or ventilating large areas such as sports centres, theatres, entertainment and industrial areas. The diffusers are able to operate at a high air throughput. The diffuser core and the outer case are made of steel. The entire assembly is powder coated in a range of standard colours. Contact your nearest Bradflo Office with your requirement. By rotating the nozzle through 360 deg., the air pattern may be adjusted from a jet pattern to a diffused pattern. Design dimensions No. of Jets 1 2 3 4 X-Size Dia. A B C H W W W W 0 46 142 132 280 280 5 760 00 2 58 177 167 3 3 6 9 315 71 227 217 395 395 7 15 1460 400 91 282 272 480 480 970 13 1800 0 116 3 3 580 580 11 16 20 Page. 57

JET DIFFUSER 2.52 AJA Sound data NR levels for the grille may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: Air pattern (with isothermal air supply) L b = distance from air device to the plane where the maximum spread occurs. O d = the jet diameter at L b L w = NR + K ok Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 0 +4-1 -2 +1-5 -12-9 2 0-1 +2-1 - -15-5 315 +2 0 +1-1 -8-13 -11 400 +3 +1 +3-1 -7-9 - 0 +3 0 +2 0-7 -8-11 Tol +/- 2 2 2 2 2 2 2 L b O d K ok with diffused pattern Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 0 +3-2 -3 +1-5 - -7 2 +1-4 -3 +2-11 -13-14 315 +2-1 +1 0-9 -19-14 400 +2 +1 +4-3 -8-11 - 0 +2 +1 +5 0 - -12-11 Tol +/- 2 2 2 2 2 2 2 K ok with jet pattern Sound absorption ΔL db The sound absorption shown relates to a reduction of the sound power level calculated from duct to room. The end reflection is included in the values. Jet Pattern Diffused Pattern O d 0 = L 0.3 x 0.13 O d 0 = L 0.3 x 0.46 O d 2 = L 0.3 x 0.08 O d 2 =L 0.3 x 0.48 O d 315 = L 0.3 x 0.11 O d 315 = L 0.3 x 0.42 O d 400 =L 0.3 x 0.13 O d 400 = L 0.3 x 0.38 O d 0 = L 0.3 x 0.13 O d 0 =L 0.3 x 0.38 L b 0 = L 0.3 x 0.27 L b 0 = L 0.3 x 0.54 L b 2 =L 0.3 x 0.33 L b 2 = L 0.3 x 0.63 L b 315 = L 0.3 x 0.34 L b 315 =L 0.3 x 0.57 L b 400 = L 0.3 x 0.45 L b 400 = L 0.3 x 0.45 L b 0 =L 0.3 x 0.45 L b 0 = L 0.3 x 0.45 Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 0 13 4 0 0 0 0 2 11 7 3 0 0 0 0 315 6 2 0 0 0 0 400 9 5 1 0 0 0 0 0 7 3 0 0 0 0 0 Tol +/- 2 2 2 2 2 2 2 Page. 58

2.52 AJA JET DIFFUSER Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. AJA Jet pattern 2 Static Pressure (Pa) 0 2 315 400 0 0 40 25 35-9 - 18 8-16 7-14 18-36 14-28 12-24 5 5-4.5-9 4-8 3.5-7 6-12 1 0 0 0 00 00 AJA Diffused pattern 2 Static Pressure (Pa) 0 2 315 400 0 5 25 40 35 12-24 - 9-18 8-16 7-14 6-12 5-4 - 8 3-6 1 0 0 0 00 00 Page. 59

JET DIFFUSER 2.52 AJA Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. AJAX Jet pattern 2 Static Pressure (Pa) 0 2 315 400 0 0 40 25 35 14-28 12-24 - 9-18 18-36 8-16 7-14 5 6-12 5-4 - 8 1 0 0 0 00 00 AJAX Diffused pattern 2 Static Pressure (Pa) 0 2 315 400 0 0 25 40 35-8 - 16 7-14 6-12 5-4 - 8 5 3.5-7 3-6 2.5-5 1 0 0 0 00 00 Page. 60

JET DIFFUSER 2.53 AJS Selection Guide Sound Selection Chart Min 25 35 0 2 Size Diameter NR db 315 MAX Recommended l/s 400 Δ T = 15 o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..N (X is the nominal neck diameter of the diffuser). Example: If your requirement is for three 2 mm diameter Jet diffusers mounted on a plate, the ordering code would be AJS23. {When ordering it is not necessary to include the periods [..]). Product Size Numbers Diffusers mounted on plate "N" "Type" "X" Size 1 2 3 4 Colour AJS 0 Powder coat white AJSX 2 315 400 0 Special colours Page. 61

2.53 AJS JET DIFFUSER Description Finish The 2.53 (AJS) diffusers are designed for air conditioning or ventilating large areas such as sports centres, theatres, entertainment and industrial areas. The diffusers are able to operate at a high air throughput. By rotating the nozzle through 360 deg., the air pattern may be adjusted from a jet pattern to a diffused pattern. The diffuser core and the outer case are made of steel. The entire assembly is powder coated in a range of standard colours. Contact your nearest Bradflo Office with your requirement. Design dimensions No. of Jets 1 2 3 4 X-Size Dia. A B C H W W W W 0 71 142 132 280 280 5 760 00 2 89 177 167 3 3 6 9 315 111 227 217 395 395 7 15 1460 400 1 282 272 480 480 970 13 1800 0 170 3 3 580 580 11 16 20 Page. 62

JET DIFFUSER 2.53 AJS Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. AJS Diffused pattern 2 Static Pressure (Pa) 0 2 315 400 0 0 40 35 25 5-4 - 8 3.5-7 5 3-6 2.5-5 2-4 1 0 0 0 00 0 0 00 AJS Jet pattern 2 Static Pressure (Pa) 0 2 315 400 0 0 40 35 25 15 - - 40 5 5-9 - 18 8-16 7-14 6-12 12-24 - 1 0 0 0 00 00 Page. 63

2.55 Bradflo FLANGED JET DIFFUSER DJD The Bradflo DJD jet nozzle allows high volumes of air to be delivered over long distances. The centre of the DJD can be rotated to allow for accurate air distribution and can be used for either jet or diffuse applications. The diffuser is constructed using spun aluminium segments, creating a lightweight and corrosion resistant jet diffuser. Standard finish is powder coated white with other colours available on request. Product Specifications PART CODE SIZE DIMENSION "A" DIMENSION "B" DIMENSION "H" DJD0P 0 272 199 164 DJD2P 2 322 249 164 DJD0P 0 372 299 181 DJD3P 3 422 349 217 DJD400P 400 472 399 2

Performance Data PRODUCT PERFORMANCE MEASURE NECK VELOCITY (m/sec) CODE DATA 2 3 4 5 6 7 DJD0P DJD2P DJD0P DJD3P DJD400P AIR FLOW l/sec 63 94 126 157 188 2 NOISE NC <15 16 23 31 38 44 PRESSURE DROP Pa 3 8 13 21 41 THROW Metres 4.2 4.9 5.6 6.3 7.1 8 AIR FLOW l/sec 98 147 196 245 295 344 NOISE NC <15 17 25 33 40 45 PRESSURE DROP Pa 3 7 13 29 40 THROW Metres 4.9 5.6 6.4 6.9 7.6 8.7 AIR FLOW l/sec 141 212 283 354 424 495 NOISE NC <15 18 27 35 42 48 PRESSURE DROP Pa 3 7 13 28 39 THROW Metres 5.8 6.4 6.9 7.4 8.1 9.2 AIR FLOW l/sec 192 289 385 481 577 673 NOISE NC 17 29 36 43 49 PRESSURE DROP Pa 3 7 12 19 28 38 THROW Metres 6.0 6.6 7.2 7.6 8.3 9.4 AIR FLOW l/sec 251 377 3 629 754 880 NOISE NC 19 22 31 39 46 54 PRESSURE DROP Pa 3 7 12 19 28 38 THROW Metres 6.3 6.8 7.5 7.9 8.7 9.8 NOTE: Throws are based on sidewall mounted 2.00m from floor in the diffuse position The distances indicated are at a terminal velocity - 0.25 m/sec. For throws with the DJD centre in the jet application, multiply the above diffuse distances x 2.

PERFORATED DIFFUSER 2.61 APD Sound Selection Chart Min 25 35 NR db Selection Guide 0 x 0-1 400 x 400-0 600 x 600-2 Size Square - Inlet Diameter MAX Recommended l/s 600 x 600-0 Δ T = 5 o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..C (X is the nominal face size of the diffuser). Example: If your requirement is for a 400 mm square perforated diffuser with a 0 mm dia inlet, the ordering code would be APD1608. {When ordering it is not necessary to include the periods [..]). "Type" "X" Size 06 (1) Product Size Numbers Inlet dia. "C" 08 (0) (2) 12 (0) Colour APD 12 (0) Powder coat white 16 (400) 24 (600) Special colours Page. 64

2.61 APD PERFORATED DIFFUSER Description Finish The 2.61 (APD) perforated diffuser is designed for flush mounting and suspended ceilings. The diffuser is available in 1,2,3 or 4-way blow configurations. Each diffuser is powdercoated white unless otherwise specified. There are 15 standard colours to choose from. The perforated face may be removed from the frame for installation and cleaning. The frames are made from aluminium with a perforated, galvanised core. Design dimensions Size X Size Inlet dia. A 0 x 0-125 0 1 B 400 x 400-0 400 0 C 600 x 600-2 600 2 D 600 x 600-0 600 0 Page. 65

PERFORATED DIFFUSER 2.61 APD Sound data NR levels for the grille may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: Air pattern (with isothermal air supply) b h = L 0.3 x 0.03 L bh = L 0.3 x 0.65 b v = L 0.3 x 0.06 L bv = L 0.3 x 0.65 L w = NR + K ok Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 A +3 +2 +5 +8 +4-6 -13 B +2 +1 +5 +8 +3 - -15 C +2 0 +5 +9 0-12 -15 D +2 0 +5 +9 +1-13 -15 Tol +/- 2 2 2 2 2 2 2 L bh b h K ok with diffused pattern b v L bv Sound absorption ΔL db L bh The sound absorption shown relates to a reduction of the sound power level calculated from duct to room. The end reflection is included in the values. Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 A 13 8 4 3 1 1 0 B 11 6 3 2 1 0 0 C 5 2 1 1 0 0 D 8 4 1 1 0 0 0 Tol +/- 2 2 2 2 2 2 2 b h Page. 66

2.61 APD PERFORATED DIFFUSER Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. APR 4-way pattern 0 Static Pressure (Pa) A B C D 35 40 25 3-6 2.5-5 2-4 5 1.5-3 1-2 1 0 0 0 00 Page. 67

PERFORATED EXHAUST GRILLE 2.62 APDE Sound Selection Chart Min 25 35 NR db Selection Guide 0 x 0 400 x 400 Size Square l/s 600 x 600 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X (X is the nominal face size of the diffuser). Example: If your requirement is for a 400 mm square perforated return air grille, the ordering code would be APDE16. {When ordering it is not necessary to include the periods [..]). Product Size Numbers "Type" "X" Size Colour APDE 12 (0) Powder coat white 16 (400) 24 (600) Special colours Page. 68

2.62 APDE PERFORATED EXHAUST GRILLE Description Finish The 2.62 (APDE) perforated grille is designed for flush mounting and suspended ceilings. The perforated face is fixed in the frame. Each diffuser is powdercoated white unless otherwise specified. There are 15 standard colours to choose from. The frames are made from aluminium with a perforated, galvanised core. Design dimensions Size X Size Y Size 0 x 0 0 244 400 x 400 400 344 600 x 600 600 544 These graphs are for selection only and should not be used for commissioning. APDE performance graph 0 Static Pressure (Pa) 0X0 400X400 600X600 40 35 25 5 1 0 0 0 00 00 Page. 69

PERFORATED CIRCULAR DIFFUSER 2.63 APR Selection Guide Sound Selection Chart Min 25 35 NR db 125 1 0 2 Size Inlet Diameter MAX Recommended l/s 0 Δ T = 8 o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..C (X is the nominal face diameter of the diffuser). Example: If your requirement is for a 400 mm dia perforated circular diffuser, the ordering code would be APR1608. {When ordering it is not necessary to include the periods [..]). "Type" "X" Size 05 (125) 06 (1) Product Size Numbers Inlet dia. "C" 08 (0) (2) 12 (0) Colour APR (2) Powder coat white 16 (400) 24 (6) Special colours Page. 70

2.63 APR PERFORATED CIRCULAR DIFFUSER Description The 2.63 (APR) is a circular perforated supply air diffuser for mounting in ceilings where exacting requirements for draught free conditions are necessary, such as in schools, offices and hotels. The air is supplied partly through the perforated side. This type of construction gives the device a high degree of induction and makes the 2.63 model suitable for systems with variable air flow, or for installations where air has to be supplied with a large negative temperature and short throw. The design provides a fully radial pattern and minimises the occurrence of dust accumulating on the ceiling. The 2.63 model can be ceiling mounted or directly mounted into exposed ductwork. Finish Each diffuser is powdercoated white unless otherwise specified. There are 15 standard colours to choose from. Design dimensions φ XSize φ Inlet C φ L 2 125 45 145 400 1 54 180 400 0 54 2 6 2 76 270 6 0 76 3 Page. 71

PERFORATED CIRCULAR DIFFUSER 2.63 APR Sound data NR levels for the grille may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: Air pattern (with isothermal air supply) b v = L 0.3 x 0.06 L bv = L 0.3 x 0.65 L w = NR + K ok Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 125 +8 +7 +8 +7 +3-8 - 160 +8 +7 +8 +8 +1-9 -12 0 +8 +5 +7 +8 +1-12 -14 2 +7 +7 +6 +7 +4-9 -12 0 +7 +5 +7 +8 0-14 -12 Tol +/- 2 2 2 2 2 2 2 L bv b v Correction factor K ok Sound absorption ΔL db The sound absorption shown relates to a reduction of the sound power level calculated from duct to room. The end reflection is included in the values. Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 125 14 9 5 3 2 1 0 160 13 8 4 3 1 1 0 0 11 6 3 2 1 0 0 2 5 2 1 1 0 0 0 8 4 1 1 0 0 0 Tol +/- 2 2 2 2 2 2 2 Page. 72

2.63 APR PERFORATED CIRCULAR DIFFUSER Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. APR performance graph 1 0 Static Pressure (Pa) 125 1 0 2 0 25 35 40 1.5-3 2-4 5 1-2 0.75-1.5 1 0 0 0 00 Page. 73

ENVIRONMENT 00 EXHAUST AIR GRILLE 2.64 APME Sound Selection Chart Min 25 35 NR db Selection Guide 0 400 Size Square l/s 600 0 0 00 00 Ordering Procedure Using the chart below select your requirement and substitute the underscored text below. Type..X (X is the nominal face size of the diffuser). Example: If your requirement is for a 400 mm square exhaust air device, the ordering code would be APME16. (When ordering it is not necessary to include the periods [..]). Product Size Numbers "Type" "X" Size Colour APME (2) Powder coat white 16 (400) 24 (6) Special colours Page. 74

2.64 APME ENVIRONMENT 00 EXHAUST AIR GRILLE Description Finish The Environment 00 range is an exclusive series of air distribution devices with diffuser components that will fit any ceiling. The 2.64 (APME) exhaust air grille matches in appearance the 2.65 and 2.66 diffusers. Standard finish is powdercoat white unless otherwise specified. There are 15 other standard colours to choose from. After installation there are no visible mounting hardware or fixing components visible. Size X Y 0 x0 0 2 400 x 400 400 3 600 x 600 600 5 Page. 75

ENVIRONMENT 00 EXHAUST AIR GRILLE 2.64 APME Applications Plaster ceiling Exposed T-Bar Concealed T-Bar Perforated centre core can be adjusted to any one of three positions from face side of grille. 0 mm, 7mm & 14 mm Adjustable gap Sound data NR levels for the grille may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: L w = NR + K ok Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 0 +13 +11 + +8 +5-1 -11 400 +15 +12 +11 +8 0-2 -3 600 +19 +14 +12 +7 +5-5 - Tol +/- 2 2 2 2 2 2 2 Page. 76

2.64 APME ENVIRONMENT 00 EXHAUST AIR GRILLE APME Exhaust air 0 Static Pressure (Pa) 0X0 400X400 600X600 35 40 25 5 1 0 0 0 00 00 These graphs are for selection only and should not be used for commissioning. Page. 77

ENVIRONMENT 00 DIFFUSER 2.65 APMF Selection Guide Sound Selection Chart Min 25 35 NR db MAX Recommended l/s 0 X 0-1 400 X 400-1 400 X 400-0 600 X 600-0 600 X 600-2 600 X 600-0 Size Square - Inlet Diameter Δ T = 12 o C 0 0 00 00 Ordering procedure Using the chart below, select your requirements and substitute the underscored text below. APMF..X..C..B Example: If your requirement is for a 400mm square diffuser with an inlet dia. of 0mm, 2-way corner blow, the ordering code would be: APMF1608C. When ordering it is not necessary to include the periods (..)). "Type" "X" Size 06 (1) Product Size Numbers Inlet dia. "C" 08 (0) (2) 12 (0) 1 Way 2 Way Blow pattern "B" 3 Way 4 Way Corner Blow Colour APMF 12 (0) C Powder coat white 16 (400) C 24 (600) C Special colours Note! Shaded areas indicate standard product. Page. 78

2.65 APMF ENVIRONMENT 00 DIFFUSER Description The 2.65 (APMF) diffuser has been designed for air conditioning systems where a draught free, quiet and pleasant atmosphere is required. They are especially suited for variable air volume systems. Through slots around the perimeter of the diffuser a primary air stream is projected along the ceiling. The volume of air out of these slots may be controlled by using the 3 position adjustment available at the face of the diffuser. The diffuser is manufactured to match the 2.64 and 2.66 models in appearance. The air pattern is fully radial and may also be supplied in either 1, 2 or 3-way patterns. Finish The standard finish is white unless otherwise specified. There are 15 other standard colours available. Size X B C φd A 0-1 0 255 0 1 B 400-1 400 355 0 1 C 400-0 400 355 0 0 D 600-0 600 555 0 0 E 600-2 600 555 0 2 F 600-0 600 555 0 0 Page. 79

ENVIRONMENT 00 DIFFUSER 2.65 APMF Applications Plaster ceiling Exposed T-Bar Concealed T-Bar Perforated centre core can be adjusted to any one of three positions from face side of grille. 0 mm, 7mm & 14 mm Adjustable gap b h 2-way pattern L bh b v L bv 2-way corner pattern 3-way pattern Refer to next page for formulas to determine the isothermal air pattern. Page. 80

2.65 APMF ENVIRONMENT 00 DIFFUSER Adjustable throw The throw may be adjusted according to the following table by raising or lowering the diffuser fascia panel. Sound absorption ΔL db The sound absorption shown relates to a reduction of the sound power level calculated from duct to room. The end reflection is included in the values. Perimeter Slot Multiply Throw by: 0mm 1.2 7mm 1.1 14 mm 1 Factors for different patterns. Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 1 13 8 4 3 1 1 0 0 11 6 3 2 1 0 0 2 5 2 1 1 0 0 0 8 4 1 1 0 0 0 Tol +/- 2 2 2 2 2 2 2 4-Way 3-Way 2-Way 2-Way Corner 1-Way b h =L 0.3 x - 0.40 1.00 0. 0.90 L bh =L 0.3 x - 0.40 0. 0.40 0. b v =L 0.3 x 0.05 0.05 0.05 0.05 0.06 L bv =L 0.3 x 0.40 0.40 0.40 0.40 0.40 L bh = distance from diffuser to maximum spread. b v = vertical spread b h = horizontal spread Sound data NR levels for the grille may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: L w = NR + K ok Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 1-3 -4-1 +2-2 -12-19 0-4 -5-1 +2-3 -16-21 2-4 -6-1 +2-6 -18-21 0-4 -6-1 +2-5 -19-21 Tol +/- 2 2 2 2 2 2 2 Correction factor K ok Page. 81

ENVIRONMENT 00 DIFFUSER 2.65 APMF Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. APMF 2-way blow 2 Static Pressure (Pa) A B C D E F 0 25 40 35 2-4 2.5-5 3-6 1.5-3 5 1-2 1 0 0 0 00 00 APMF 1-way blow 2 Static Pressure (Pa) A B C D E F 0 25 35 40 2-4 2.5-5 3-6 5 1.5-3 1 0 0 0 00 Page. 82

2.65 APMF ENVIRONMENT 00 DIFFUSER Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s These graphs are for selection only and should not be used for commissioning. APMF 4-way blow 2 Static Pressure (Pa) A B C D E F 0 35 40 3-6 25 2.5-5 2-4 1.5-3 5 1-2 1 0 0 0 00 00 APMF 3-way blow 2 Static Pressure (Pa) A B C D E F 0 35 25 40 3-6 2.5-5 2-4 1-2 1.5-3 5 1 0 0 00 00 Page. 83

ENVIRONMENT 00 DIFFUSER WITH MULTI- FUNCTION PLENUM 2.66 APM Sound Selection Chart Min 25 35 NR db Selection Guide 0 x 0-1 400 x 400-0 600 x 600-2 Size Square - Inlet Diameter MAX Recommended l/s 600 x 600-0 Δ T = 12 o C 0 0 00 00 Ordering procedure Using the chart below select your requirement and substitute the underscored text below. Type..X..C..B (X is the nominal face size of the diffuser). Example: If your requirement is for a 400 mm square multi-function plenum with a 0 mm inlet, corner blow, the ordering code would be APM1608C (When ordering it is not necessary to include the periods[..]). "Type" "X" Size 06 (1) Product Size Numbers Inlet dia. "C" 08 (0) (2) 12 (0) 1 2 Way Blow pattern "B" 3 Way 4 Way Corner Blow Colour APM 12 (0) C Powder coat white 16 (400) C 24 (600) C Special colours Page. 84

2.66 APM ENVIRONMENT 00 DIFFUSER WITH MULTI- FUNCTION PLENUM Description The 2.66 (APM) diffuser has been designed for air conditioning systems where a draught free, quiet and pleasant atmosphere is required. They are especially suited for variable air volume systems. Through slots around the perimeter of the diffuser a primary air stream is projected along the ceiling. The volume of air out of these slots may be controlled by using the 3 position adjustment available at the face of the diffuser. The diffuser is manufactured to match the 2.64 and 2.66 models in appearance. The air pattern is fully radial and may also be supplied in either 1, 2 or 3-way patterns. The pressure reducing plenum chamber contains a regulating damper, sound attenuation and balancing system. This system eliminates the need to remove any part of the ceiling or diffuser during air balancing. Finish The standard finish is white unless otherwise specified. There are 15 other standard colours available. Design dimensions Size X B C D A 0-1 0 0 1 254 B 400-1 400 0 1 354 C 400-0 400 3 0 354 D 600-0 600 3 0 554 E 600-2 600 400 2 554 F 600-0 600 4 0 554 Page. 85

ENVIRONMENT 00 DIFFUSER WITH MULTI- FUNCTION PLENUM 2.66 APM Applications Plaster ceiling Exposed T-Bar Concealed T-Bar Perforated centre core can be adjusted to any one of three positions from face side of grille. 0 mm, 7mm & 14 mm Adjustable gap b h 2-way pattern L bh b v L bv 2-way corner pattern 3-way pattern Refer to next page for formulas to determine the isothermal air pattern. Page. 86

2.66 APM ENVIRONMENT 00 DIFFUSER WITH MULTI- FUNCTION PLENUM Adjustable throw The throw may be adjusted according to the following table by raising or lowering the diffuser fascia panel. Perimeter Slot Multiply Throw by: 0mm 1.2 7mm 1.1 14 mm 1 Factors for different patterns. 4-Way 3-Way 2-Way 2-Way Corner 1-Way b h =L 0.3 x - 0.40 1.00 0. 0.90 L bh =L 0.3 x - 0.40 0. 0.40 0. b v =L 0.3 x 0.05 0.05 0.05 0.05 0.06 L bv =L 0.3 x 0.40 0.40 0.40 0.40 0.40 L bh = distance from diffuser to maximum spread. b v = vertical spread b h = horizontal spread Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 0-1 Open +16 +13 +7 +8-3 - -18 Closed +4 +12 +9 +5 +3 +2-3 400-1 Open +15 +12 +6 +6 +3-12 -18 Closed +15 +14 +8 +8 +3 +2-2 400-0 Open +19 +12 +7 +6-6 -14 - Closed +7 +9 +5 +6 +2 +2 +1 600-0 Open +14 +8 +3 +8-2 -9-18 Closed +22 + +7 +7 0-5 -8 600-2 Open + +12 +7 +4-5 -12-16 Closed +22 + +7 +5-3 -8-8 600-0 Open +17 +9 +7 +4-8 -16-21 Closed +15 + +6 +6 +1 0-5 Tol +/- 2 2 2 2 2 2 2 Correction factor K ok Sound absorption ΔL db The sound absorption shown relates to a reduction of the sound power level calculated from duct to room. The end reflection is included in the values. Sound data NR levels for the grille may be determined from the engineering graph. Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 0-1 16 16 13 14 18 18 400-1 13 15 13 15 18 17 15 400-0 13 15 13 15 18 17 15 600-0 13 15 13 15 18 17 15 600-2 12 15 13 15 18 17 15 600-0 8 14 13 15 18 16 15 Tol +/- 2 2 2 2 2 2 2 Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: L w = NR + K ok Page. 87

ENVIRONMENT 00 DIFFUSER WITH MULTI- FUNCTION PLENUM 2.66 APM Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s APM 0 x 0-1 4 WAY BLOW APM 0 x 0-1 3 WAY BLOW Static Pressure (Pa) 0 Damper 40 C O Static Pressure (Pa) 0 Damper 40 C O 35 35 0 0 25 1-2 1.5-3 0 0 25 1.5-3 0.5-1 1-2 0.5-1 0 0 0 0 These graphs are for selection only and should not be used for commissioning. APM 0 x 0-1 APM 0 x 0-1 2 WAY BLOW 1 WAY BLOW Static Pressure (Pa) 0 Damper 40 C O Static Pressure (Pa) 0 Damper 40 C O 35 35 0 0 0 25 1.5-3 0 25 2-4 1-2 1.5-3 0.5-1 1-2 0.5-1 0 0 0 0 Page. 88

2.66 APM ENVIRONMENT 00 DIFFUSER WITH MULTI- FUNCTION PLENUM Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s APM 400 x 400-1 4 WAY BLOW APM 400 x 400-1 3 WAY BLOW Static Pressure (Pa) 0 Damper 40 C Static Pressure (Pa) 0 Damper 40 C 35 O 35 O 0 25 0 25 0 1-2 0 1-2 0.5-1 0.5-1 0.3-0.6 0.3-0.6 0 0 0 0 These graphs are for selection only and should not be used for commissioning. APM 400 x 400-1 APM 400 x 400-1 2 WAY BLOW 1 WAY BLOW Static Pressure (Pa) 0 Damper 40 C Static Pressure (Pa) 0 Damper 40 C 35 O 35 O 0 25 0 25 1.5-3 0 0 1.5-3 1-2 0.5-1 1-2 0.3-0.6 0.5-1 0 0 0 0 Page. 89

ENVIRONMENT 00 DIFFUSER WITH MULTI- FUNCTION PLENUM 2.66 APM Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s APM 400 x 400-0 APM 400 x 400-0 4 WAY BLOW 3 WAY BLOW Static Pressure (Pa) Damper C 40 0 35 Static Pressure (Pa) Damper C 40 0 35 25 O 25 O 0 0 0 0 1.5-3 1.5-3 1-2 1-2 0.5-1 0.5-1 0 0 0 0 0 0 These graphs are for selection only and should not be used for commissioning. APM 400 x 400-0 APM 400 x 400-0 2 WAY BLOW 1 WAY BLOW Static Pressure (Pa) Damper C 40 0 35 Static Pressure (Pa) Damper C 40 0 35 25 O 25 O 0 0 0 2-4 0 2.5-5 1.5-3 2-4 1.5-3 0.5-1 1-2 0 0 0 0 0 0 Page. 90

2.66 APM ENVIRONMENT 00 DIFFUSER WITH MULTI- FUNCTION PLENUM Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s APM 600 x 600-0 4 WAY BLOW APM 600 x 600-0 3 WAY BLOW Static Pressure (Pa) 0 Damper C O Static Pressure (Pa) 0 Damper C O 40 40 0 35 0 35 25 25 0 2-4 0 2-4 1.5-3 1.5-3 1-2 1-2 0.5-1 0 0 0 0.5-1 0 0 0 These graphs are for selection only and should not be used for commissioning. APM 600 x 600-0 APM 600 x 600-0 2 WAY BLOW 1 WAY BLOW Static Pressure (Pa) 0 Damper C O Static Pressure (Pa) 0 Damper C O 40 40 0 35 0 35 0 25 2.5-5 0 25 3-6 2-4 2.5-5 1.5-3 2-4 1-2 1.5-3 0 0 0 0 0 0 Page. 91

ENVIRONMENT 00 DIFFUSER WITH MULTI- FUNCTION PLENUM 2.66 APM Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Other terminal velocities may be calculated using formulas in Section 4.2 of the Air Handling Reference Guide. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s APM 600 x 600-2 4 WAY BLOW APM 600 x 600-2 3 WAY BLOW Static Pressure (Pa) 0 Damper 40 C Static Pressure (Pa) 0 Damper 40 C 35 35 0 O 0 O 25 25 0 0 2.5-5 2-4 2-4 1.5-3 1.5-3 0 1-2 0 0 0 1-2 0 0 These graphs are for selection only and should not be used for commissioning. APM 600 x 600-2 APM 600 x 600-2 2 WAY BLOW 1 WAY BLOW Static Pressure (Pa) 0 Damper 40 C Static Pressure (Pa) 0 Damper 40 C 35 35 0 O 0 O 25 25 0 0 3-6 2.5-5 2.5-5 2-4 1.5-3 2-4 0 0 0 0 1.5-3 0 0 Page. 92

2.66 APM ENVIRONMENT 00 DIFFUSER WITH MULTI- FUNCTION PLENUM Engineering Graphs Throws shown are to a terminal velocity of 0.60 m/s and 0. m/s. Other terminal velocities may be calculated using formulas in Section 4.2 of the Air Handling Reference Guide. Terminal velocity 0.60 m/s 0. m/s Approximate air velocity in room 0. m/s 0.15 m/s APM 600 x 600-0 4 WAY BLOW APM 600 x 600-0 3 WAY BLOW Static Pressure (Pa) 0 Damper C Static Pressure (Pa) 0 Damper C 40 40 0 35 0 35 0 25 O 0 25 O 2-4 2-4 1.5-3 1.5-3 1-2 1-2 0 0 0 0 0 0 These graphs are for selection only and should not be used for commissioning. APM 600 x 600-0 APM 600 x 600-0 2 WAY BLOW 1 WAY BLOW Static Pressure (Pa) 0 Damper C Static Pressure (Pa) 0 Damper C 40 40 0 35 0 35 0 25 O 0 25 O 2.5-5 3-6 2-4 2.5-5 1.5-3 2-4 0 1-2 0 0 0 1.5-3 0 0 Page. 93

ENVIRONMENT 00 DIFFUSER WITH MULTI- FUNCTION PLENUM 2.66 APM BALANCING GRAPH 1 0 Static Pressure (Pa) 1 0 2 0 5 1 0 0 0 00 0 0 These graphs are for selection only and should not be used for commissioning. Page. 94

4 FITTINGS & ACCESSORIES Dampers, Equalisers & Measures 5 FLEXIBLE DUCTING HOME PLENUMS Chapter Description Product Code 3.11 3.12 3.13 3.31 3.33 Plenum box Insulated plenum box Plenum box with measurer Linear plenum box Linear plenum box with measurer ADC ADCI ADE ASA ASE 1 GRILLES & LOUVRES 3 PLENUMS 2 DIFFUSERS

PLENUM BOX 3.11 ADC Description The 3.11 plenum box is for use with grilles and diffusers. The plenum is manufactured from galvanised steel. Ordering procedure Using the chart below, select your requirement and substitute the underscored text ADC..X..Y..D Example:If your requirement is for a 375 mm square plenum with a 0 mm dia. inlet, the ordering code would be: ADC1518 Other sizes are available upon request. Please contact your nearest Bradflo office. "Type" "X" Size 06 (1) 08 (0) Product Size Numbers 09 (225) (2) "Y" Size 12 (0) 15 (375) 16 (400) 18 (4) 24 (600) Inlet Dia. "D" ADC 06 (1) 06 (1) 08 (0) 08 (0) 09 (225) (2) (2) 12 (0) 12 (0) 15 (375) 16 (400) 18 (4) Special sizes 24 (600) Page. 1

3.11 ADC PLENUM BOX Design dimensions Inlet larger than the outlet Inlet smaller than the outlet Page. 2

INSULATED PLENUM BOX 3.12 ADCI Description The 3.12 insulated plenum box is for use with grilles and diffusers. The plenum is manufactured from galvanised steel and internally insulated with black faced glasswool. Other types of insulation is available upon request including external polyurethane foam. Ordering procedure Using the chart below, select your requirement and substitute the underscored text ADCI..X..Y..D Example:If your requirement is for a 375 mm square plenum with a 0 mm dia. inlet, the ordering code would be: ADCI1518 Other sizes are available upon request. Please contact your nearest Bradflo office. "Type" "X" Size 06 (1) 08 (0) Product Size Numbers 09 (225) (2) "Y" Size 12 (0) 15 (375) 16 (400) 18 (4) 24 (600) Inlet Dia. "D" ADCI 06 (1) 06 (1) 08 (0) 08 (0) 09 (225) (2) (2) 12 (0) 12 (0) 15 (375) 16 (400) 18 (4) Special sizes 24 (600) Page. 3

3.12 ADCI INSULATED PLENUM BOX Design dimensions Page. 4

PLENUM BOX WITH MEASURER 3.13 ADE Selection Guide Sound Selection Chart Min 25 35 NR db l/s 1 Inlet Diameter 0 Inlet Diameter 2 Inlet Diameter 0 Inlet Diameter 3 Inlet Diameter Size 0 0 00 00 Ordering Procedure Using the chart below, select your requirements and substitute the underscored text below. Type..X..Y..D Example: If your requirement is for a 0mm square plenum with a 0mm dia inlet, the ordering code would be: ADE..12..12..08. (When ordering it is not necessary to include the periods (..)). Note! Other sizes are available upon request. Please contact your nearest Bradflo of "Type" "X" Size 06 (1) 08 (0) Product Size Numbers 09 (225) (2) "Y" Size 12 (0) 15 (375) 16 (400) 18 (4) 24 (600) Inlet Dia. "D" ADE 06 (1) 06 (1) 08 (0) 08 (0) 09 (225) (2) (2) 12 (0) 12 (0) 15 (375) 16 (400) 18 (4) Special sizes 24 (600) Page. 5

3.13 ADE PLENUM BOX WITH MEASURER Description method of measuring and balancing air flow. The 3.13 ADE plenums provide multiple functions by incorporating into the acoustically designed plenum, a damper and measuring device. The multi-function plenum provides a technical, acoustically highly effective air terminal device for use with all types of square, rectangular and circular diffusers. It includes a measuring and balancing device which provides a simple and effective The damper is operated through the face of the diffuser as is the connections for the measuring device. The design of the plenum provides even air flow across the face of the diffuser. The plenum is manufactured from galvanised steel. Design dimensions Page. 6

PLENUM BOX WITH MEASURER 3.13 ADE Sound data NR levels for the grille may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: L w = NR + K ok Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 1 +22 _17 +7 +7 +5-4 -16 0 +27 +16 +5 +6 +5-5 -18 2 +24 +16 +4 +5 +4-6 -19 0 +21 +13 +6 +7 +5-7 -23 3 +22 +14 +5 +6 +5-7 -23 Tol +/- 2 2 2 2 2 2 2 K ok with jet pattern Sound absorption ΔL db The sound absorption shown relates to a reduction of the sound power level calculated from duct to room. The end reflection is included in the values. Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 1 14 8 8 8 9 7 0 11 9 8 7 9 7 7 2 11 7 7 6 8 7 6 0 9 8 7 5 7 7 7 3 8 6 5 6 7 6 7 Tol +/- 2 2 2 2 2 2 2 Page. 7

3.13 ADE PLENUM BOX WITH MEASURER 1 Inlet diameter 0 Inlet diameter 00 Static Pressure (Pa) Damper C 00 Static Pressure (Pa) Damper C 0 0 25 35 40 O 0 0 40 35 25 O 0 0 0 0 0 0 0 These graphs are for selection only and should not be used for commissioning 2 Inlet diameter 0 Inlet diameter 00 Static Pressure (Pa) Damper C 00 Static Pressure (Pa) Damper C 0 0 0 40 35 25 O 0 0 0 40 35 25 O 0 0 0 0 0 0 Page. 8

PLENUM BOX WITH MEASURER 3.13 ADE 3 Inlet diameter 00 Static Pressure (Pa) Damper C 0 40 35 0 25 O 0 0 0 0 00 Balancing graph 1 0 Static Pressure (Pa) 125 1 175 0 225 2 0 3 400 5 1 0 0 0 00 00 Example: If the measured differential pressure was 45 Pa and the size of the inlet 0 mm dia., the flow rate would be approximately 170 l/s Page. 9

LINEAR PLENUM 3.31 ASA Description The ASA is a plenum suitable for use with all types of linear grilles and diffusers. It is manufactured from galvanised steel. Ordering procedure Using the chart below, select your requirements and sustitute the underscored text ASA..N..U..D..E Example: If your requirement is for a 4 slot mm long linear plenum with a 0 mm dia. inlet and a left hand end, the ordering code would be: ASA..4..48..08..EL (When ordering it is not necessary to include the periods [..]) Other sizes are available upon request. Please contact your nearest Bradflo office. Product Size Numbers "Type" No. of Slots "N" Length "X" Inlet dia. "D" No. of Ends "E" Colour ASA 1 24 (600) 08 (0) 0E (No ends) Matt black on 2 36 (900) 09 (225) EL (One end left) inside faces 3 48 () (2) ER (One end right) 4 60 (1800) 2E (Two ends) 5 6 7 8 Page.

3.31 ASA LINEAR PLENUM Design dimensions Page. 11

PLENUM BOX WITH MEASURER FOR LINEAR DIFFUSERS 3.33 ASE Selection Guide Sound Selection Chart Min 25 35 NR db l/s 2 Slots x 00-0 2 Slots x - 225 2 Slots x 1800-2 4 Slots x 1800-2 6-8 Slots x 1800-0 Size 0 0 00 00 Ordering Procedure Using the chart below, select your requirements and substitute the underscored text below. Type..N..X..D..E Example: If your requirement is for a 0mm square plenum with a 0mm dia inlet, the ordering code would be: ASE..4..48..08..EL. (When ordering it is not necessary to include the periods (..)). Note! Other sizes are available upon request. Please contact your nearest Bradflo of Product Size Numbers "Type" No. of Slots "N" Length "X" Inlet dia. "D" No. of Ends "E" Colour ASE 1 24 (600) 08 (0) 0E (No ends) Matt black on 2 36 (900) 09 (225) EL (One end left) inside faces 3 48 () (2) ER (One end right) 4 60 (1800) 2E (Two ends) 5 6 7 8 Page. 12

3.33 ASE PLENUM BOX WITH MEASURER FOR LINEAR DIFFUSERS Description The 3.33 ASE plenums provide multiple functions by incorporating into the acoustically designed plenum, a damper and measuring device. The multi-function plenum provides a technical, acoustically highly effective air terminal device for use with all types of square, rectangular and circular diffusers. It includes a measuring and balancing device which provides a simple and effective method of measuring and balancing air flow. The damper is operated through the face of the diffuser as is the connections for the measuring device. The design of the plenum provides even air flow across the face of the diffuser. The plenum is manufactured from galvanised steel. Design dimensions Page. 13

PLENUM BOX WITH MEASURER FOR LINEAR DIFFUSERS 3.33 ASE Sound data NR levels for the grille may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: L w = NR + K ok Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 0 +27 +16 +5 +6 +5-5 -18 225 +26 +16 +5 +6 +5-5 -18 2 +24 +16 +4 +5 +4-6 -19 0 +21 +13 +6 +7 +5-7 -23 Tol +/- 2 2 2 2 2 2 2 K ok with jet pattern Sound absorption ΔL db The sound absorption shown relates to a reduction of the sound power level calculated from duct to room. The end reflection is included in the values. Frequency (cycles per second) Size 125 2 0 00 00 4000 8000 0 8 7 9 13 7 11 225 7 6 8 11 6 2 6 6 8 6 9 0 5 6 7 9 5 9 8 Tol +/- 2 2 2 2 2 2 2 Page. 14

3.33 ASE PLENUM BOX WITH MEASURER FOR LINEAR DIFFUSERS 2 slots x 00 x 0 Inlet diameter 2 slots x x 225 Inlet diameter 2 Static Pressure (Pa) Damper C 35 O 2 Static Pressure (Pa) Damper C 35 0 25 0 25 O 1 0 0 1 0 0 0 0 These graphs are for selection only and should not be used for commissioning 2 slots x 10 x 2 Inlet diameter 2 Static Pressure (Pa) Damper C 35 O 0 25 1 0 0 0 Page. 15

PLENUM BOX WITH MEASURER FOR LINEAR DIFFUSERS 3.33 ASE 4 slots x 00 x 0 Inlet diameter 4 slots x x 225 Inlet diameter 2 Static Pressure (Pa) Damper C 35 O 2 Static Pressure (Pa) Damper 35 C 0 25 0 25 O 1 0 0 1 0 0 0 0 These graphs are for selection only and should not be used for commissioning 4 slots x 10 x 2 Inlet diameter 2 Static Pressure (Pa) Damper C 35 0 25 O 1 0 0 0 Page. 16

3.33 ASE PLENUM BOX WITH MEASURER FOR LINEAR DIFFUSERS 8 slots x 00 x 225 Inlet diameter 8 slots x x 2 Inlet diameter Static Pressure (Pa) Damper 2 35 C 2 Static Pressure (Pa) Damper C 0 25 O 0 25 35 O 1 0 0 1 0 0 0 0 These graphs are for selection only and should not be used for commissioning 8 slots x 10 x 0 Inlet diameter 2 Static Pressure (Pa) Damper C 35 0 25 O 1 0 0 0 Page. 17

PLENUM BOX WITH MEASURER FOR LINEAR DIFFUSERS 3.33 ASE Balancing graph 1 0 Static Pressure (Pa) 125 1 175 0 225 2 0 3 400 5 1 0 0 0 00 00 Example: If the measured differential pressure was 45 Pa and the size of the inlet 0 mm dia., the flow rate would be approximately 170 l/s Page. 18

5 FLEXIBLE DUCTING HOME FITTINGS & ACCESSORIES Dampers, Equalisers & Measures Chapter Description Product Code 4.11 4.21 4.31 4.32 4.34 4.35 4.36 End-line duct measurer Measuring unit with balancing damper Opposed blade damper Damper & equalising deflector Adjustable steam splitter Adjustable steam splitter Bellmouth spigot AMU ARU AOB ACK ASSD AED AHSP 1 2 3 4 GRILLES & LOUVRES DIFFUSERS PLENUMS FITTINGS & ACCESSORIES Dampers, Equalisers & Measures

END-LINE DUCT MEASURER 4.11 AMU Selection Guide Sound Selection Chart Min 35 40 45 NR db l/s 1 0 2 0 3 400 Size 0 0 00 00 Ordering procedure Using the chart below, select your requirements and substitute the underscored text below Type..X Example: If your requirement is for a 0mm diameter end-line measurer, and you wish to measure through the face of the grille, the ordering code would be: AMC0 (When ordering it is not necessary to include the periods [..]) Product Size Numbers "Type" "X" Size Colour AMC 125 AME 1 0 2 0 3 400 4 Special Page. 1

4.11 AMU END-LINE DUCT MEASURER Description The end-line measurer is a fixed air measuring device for mounting in circular ductwork. It provides a very simple and highly accurate method of measuring the air flow. The air flow rate is determined by measurement of the differential pressure across the mid mounted sensor then cross referenced to the diameter of the end-line measurer. Sound data NR levels for the diffuser may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: L w = NR + K ok Frequency (cycles per second Hz) Size 125 2 0 00 00 4000 8000 125 +15 +9 +1-6 -13-21 -28 1 +15 +6-3 -9-13 - -29 175 +15 +6-2 -6-11 -18-27 0 +17 +7 +1-3 -6-13 -21 225 +17 +7 0-4 -6-13 -19 2 +17 +6-1 -5-7 -13-19 0 +17 +6-2 -5-9 -15-25 3 +17 +7-1 -3-7 -14-22 400 +17 +5 +1-1 -5-14 -21 4 +16 +5 0-1 -4-13 - Tol +/- 2 2 2 2 2 2 2 Page. 2

END-LINE DUCT MEASURER 4.11 AMU Engineering graphs The performance data graph is not to be used for balancing. Performance data 1 0 Static Pressure (Pa) 125 1 175 0 225 2 0 3 400 4 0 45 5 40 35 5 1 0 0 0 00 These graphs are for selection only and should not be used for commissioning 00 Balancing graph 1 0 Differential Pressure (Pa) 125 1 175 0 225 2 0 3 400 4 0 5 1 0 0 0 00 Example: If the measured differential pressure was 45 Pa and the size of the measurer 175mm diameter, the flow rate would be approximately 1 l/s 00 Page. 3

MEASURING UNIT WITH BALANCING DAMPER 4.21 ARU Selection Guide Sound Selection Chart Min 35 40 45 NR db l/s 1 0 2 0 3 400 Size 0 0 00 00 Ordering procedure Using the chart below, select your requirements and substitute the underscored text below Type..X Example: If your requirement is for a 0mm diameter end-line measurer, and you wish to measure through the face of the grille, the ordering code would be: ARC0 (When ordering it is not necessary to include the periods [..]) Product Size Numbers "Type" "X" Size Colour ARC 125 ARE 1 0 2 0 3 400 4 Special Page. 4

4.21 ARU MEASURING UNIT WITH BALANCING DAMPER Description The 4.21 ARU is a fixed air measuring device for mounting in circular ductwork. It provides a very simple and highly accurate method of measuring the air flow. The air flow rate is determined by measurement of the differential pressure across the mid mounted sensor then cross referenced to the diameter of the measuring unit. There are two different models for damper adjustment. The ARC model with inside control cords and test tubes which must be accessed through the face of the grille or diffuser and the ARE model which has the damper control and test tubes external to the unit. A control motor may be fitted to the ARE model. The unit is constructed out of galvanised steel. Design dimensions ARC model Design dimensions ARE model XSize B 125 340 1 360 0 380 2 425 0 480 3 545 400 560 4 590 Page. 5

MEASURING UNIT WITH BALANCING DAMPER 4.21 ARU Sound data NR levels for the diffuser may be determined from the engineering graph. Sound power level L w The generated sound power level L w db is calculated by adding the correction factor K ok (see table below) to the sound level NR db according to the formula: Frequency (cycles per second Hz) Size 125 2 0 00 00 4000 8000 125 +16 +7-1 - +17-28 -33 1 +16 +8 0-7 +13-23 -29 0 +16 +6-3 -9-14 -23-32 2 +16 +8-2 -5 - -19-27 0 +15 +9 +1-3 -8-18 -27 3 +15 +9 +1-2 -7-18 -26 400 +15 +8-2 -1-7 -18-24 4 +15 +8 _3-1 -7-18 -24 Tol +/- 2 2 2 2 2 2 2 L w = NR + K ok Engineering graphs To determine the air flow using measured differential pressure, refer to the balancing graph at the end of this section. ARU Size 125 dia. ARU Size 1 dia. 2 Static Pressure (Pa) 45 Damper C 2 Static Pressure (Pa) Damper 45 C 0 40 0 40 O 35 O 35 5 5 1 0 1 0 0 These graphs are for selection only and should not be used for commissioning Page. 6

4.21 ARU MEASURING UNIT WITH BALANCING DAMPER ARU Size 0 dia. ARU Size 2 dia. 2 0 Static Pressure (Pa) Damper 45 40 35 C O 2 0 Static Pressure (Pa) Damper 45 40 35 C O 5 5 1 0 0 1 0 0 0 These graphs are for selection only and should not be used for commissioning ARU Size 0 dia. ARU Size 3 dia. 2 Static Pressure (Pa) Damper 45 C 0 Static Pressure (Pa) C Damper 0 40 35 0 40 45 O 0 35 O 5 1 0 0 0 0 0 0 00 Page. 7

MEASURING UNIT WITH BALANCING DAMPER 4.21 ARU ARU Size 400 dia. ARU Size 4 dia. 0 Static Pressure (Pa) C Damper 0 Static Pressure (Pa) Damper C 45 45 0 40 0 40 35 O 35 0 0 O 0 0 0 00 00 0 0 0 00 00 These graphs are for selection only and should not be used for commissioning Balancing graph 1 0 Differential Pressure (Pa) 125 1 0 2 0 3 400 4 0 5 1 0 0 0 00 00 Example: If the measured differential pressure was 45 Pa and the size of the measurer 0mm diameter, the flow rate would be approximately 170 l/s Page. 8

OPPOSED BLADE DAMPER 4.31 AOB Selection Guide Sound Selection Chart Min 25 35 NR db l/s 1 X 0 1 X 4 1 X 600 0 X 600 2 X 600 0 X 600 0 X 900 Size 0 0 00 00 Ordering Procedure Using the chart below, select your requirements and substitute the underscored text below. AOBD..X..Y Example: If your requirement is for a 0mm square opposed blade damper, the ordering code would be: AOBD0808 (When ordering it is not necessary to include the periods (..)). Special sizes are available upon request. Contact your nearest Bradflo Office. "Type" "X" Size 06 (1) Product Size Numbers 08 (0) "Y" Size (2) 12 (0) 14 (3) 16 (400) 18 (4) (0) 24 (600) 36 (900) Colour AOBD 06 (1) Black 08 (0) (2) 12 (0) 14 (3) 16 (400) 18 (4) Special Page. 9

4.31 AOB OPPOSED BLADE DAMPER Description The 4.31 opposed blade damper has been designed to fit on grilles. Adjustment is carried out through the face of the grille. The damper is manufactured from extruded aluminium and is painted matt black as standard. Design dimensions Note! Maximum X size is 4 mm per section. For larger grilles, dampers must be made in sections to suit. Page.

OPPOSED BLADE DAMPER 4.31 AOB Sound data NR levels for the damper may be determined from the engineering graph. 5 Throttled damper / Open damper 4 3 2 1 0 5 15 Free area in m 2 for standard sizes. X/Y 0 0 400 0 600 7 900 1 0.02 0.04 0.05 0.06 0.07 0. 0.11 0.15 0 0.03 0.05 0.07 0.08 0. 0.13 0.15 0.21 2 0.04 0.06 0.08 0. 0.13 0.16 0.19 0.26 0 0.05 0.08 0. 0.13 0.16 0. 0.23 0.31 3 0.06 0.09 0.12 0.15 0.18 0.23 0.27 0.36 400 0.07 0. 0.14 0.17 0.21 0.26 0.31 0.42 4 0.08 0.11 0.16 0. 0.23 0.29 0.35 0.47 Static Pressure (Pa) 0.05 0.08 0.12 0.18 0.03 0.04 0.06 0. 0.15 0.24 40 0.33 5 25 35 1 0 0 00 0 0 These graphs are for selection only and should not be used for commissioning. Page. 11

DAMPER & EQUALISING DEFLECTOR 4.32 ACK Description The 4.32 circular damper with equalising grid has individualy adjustable blades to regulate flow. The damper body is manufactured from galvanised steel and the blades extruded aluminium. Finish The standard finish is matt black. Ordering procedure Using the chart below, select your requirement and substitute the underscored text below ACK..X Example: If your requirement is for a 0 diameter damper, the ordering code would be: ACK0 (When odering it is not neccessary to include the periods [..]) Product Size Numbers "Type" "X" Size Colour ACK 125 Black 160 0 315 400 Special Page. 12

4.32 ACK DAMPER & EQUALISING DEFLECTOR Design dimensions Page. 13

ADJUSTABLE STREAM SPLITTER 4.34 ASSD Description The 4.34 (ASSD) adjustable stream splitter is designed for use on large duct take offs in industrial or relatively low cost commercial systems. The stream splitter damper has a screw adjustment through the face of the grille or diffuser. Standard finish is matt black over galvanised steel. Ordering Procedure Using the chart below, select your requirements and substitute the underscored text below. ASSD..X..Y Example: If your requirement is for a 0mm x 400mm damper, the ordering code would be: ASSD..08..16. (When ordering it is not neccessary to include the periods (..)). Specials sizes are available. Contact your nearest Bradflo office. Product Size Numbers "Y" Size "Type" "X" Size 06 08 09 12 15 16 (1) (0) (225) (2) (0) (375) (400) Colour ASSD 06 (1) Black Special 08 (0) 09 (225) (2) 12 (0) 15 (375) 18 (4) 24 (600) Page. 14

4.34 ASSD ADJUSTABLE STREAM SPLITTER Design dimensions Note! C = (X x 0.258) + Page. 15

ADJUSTABLE STREAM SPLITTER 4.35 AED Description The 4.35 (AED) equalising grid spreads the airflow over the face of the grille or diffuser. Th air equalising grid has individual adjustable blades. The grid is manufactured from galvanised steel with aluminium extruded blades. The finish is matt black. Ordering Procedure Using the chart below, select your requirements and substitute the underscored text below. Type..X..Y for square grids or Type..X for circular grids. Example: If your requirement is for a 0mm x 400mm grid, the ordering code would be: AED..0..400. (When ordering it is not neccessary to include the periods (..)). Other sizes are available upon request. Contact your nearest Bradflo office. Product Size Numbers "Y" Size "Type" "X" Size 1 0 2 0 400 4 0 600 Colour AED (square) 1 Black AEDC (Circular) 0 2 0 400 4 0 600 Special Page. 16

4.35 AED ADJUSTABLE STREAM SPLITTER Design dimensions Page. 17

BELLMOUTH SPIGOT 4.36 AHSP Description The bellmouth spigot and damper is a high efficiency, energy saving product suitable for both high and low velocity applications. The spigot is manufactured from galvanised steel. Ordering procedure Using the chart below, select your requirement and substitute the underscored text Type..D Example: If your requirement is for an 8 (0 mm) diameter bellmouth spigot with a damper fitted, the ordering code would be AHSPD08 Product Size Numbers "Type" "X" Size Colour AHSP 5 (125) AHSPD 6 (1) 7 (175) 8 (0) 9 (225) (2) 12 (0) Page. 18

4.36 AHSP BELLMOUTH SPIGOT Design dimensions NOMINAL FLEX SIZE "A" LENGTH "B" BELLMOUTH FLANGE DIMENSIONS HOLE "C" DIAMETER "D" mm 125 mm 165 mm 0 mm 225 1 165 225 255 175 165 255 280 0 165 280 5 225 165 5 3 2 165 3 355 0 165 380 405 Page. 19

BELLMOUTH SPIGOT 4.36 AHSP Performance comparison (1mm duct) 0 Static Pressure (Pa) SPIN-IN SPIGOT 175 1 125 SPUN ALUM FLANGED SPIGOT BELLMOUTH SPIGOT Comparative static pressure/ airflow tests indicate that the bellmouth spigot is over % more efficient than equivalent spun aluminium or steel flanged spigots or spin-in spigots. 0 75 25 0 0 25 75 0 125 1 175 0 225 2 275 0 Performance data 0 tests undertaken without ducting Static Pressure (Pa) mouth spigots has been based on The performance data for the bell- 175 1 125 attached. The additional pressure drop resulting from the flexible ducting needs to be accounted for in the final calculations. 0 75 25 0 0 0 0 0 400 0 600 700 800 900 00 10 Page.

HOME FLEXIBLE DUCTING Chapter Description Product Code 5. 5.12 5.14 5.15 5.16 5.17 5.18 5. 5.21 5.22 5.25 5.26 5.27 Fabriflex R1 duct Rollflex duct Extractaflex industrial duct Isodec R1 duct Acoustflex R1 duct 3Zero3 R0.6 polyester duct Aludec 4 Zero nude core 3Zero3 R0.6 polyester duct BC Flex R1 glasswool duct BC Flex R0.6 polyester duct 3Zero3 R1.0 insulated duct Polyfab R1 polyester duct Iscodec poly insulated duct AF AFL AHE AIS AIL A3ZDP AAL A3ZDP ABCD ABCD A3ZDP AFPB AIS 1 4 FITTINGS & ACCESSORIES 2 3 5 GRILLES & LOUVRES DIFFUSERS PLENUMS FLEXIBLE DUCTING Dampers, Equalisers & Measures

FABRIFLEX R1.0 DUCT 5. AF Description Fabriflex ducting is made from aluminised fabric with an external metal helix formed to clamp the edges of the fabric in a mechanical lock. No adhesives are used. The metal helix gives the duct strength durability and scuff resistance. The duct is insulated with a glasswool blanket (R value of 1.0 m 2 W/K) which is protected by a outer vapourbarrier sleeve. The duct assembly is lightweight, easy to handle and extremely flexible, Fabriflex ducting can be compressed to less than a quarter of its normal extended length. The duct is suitable for both high and low pressure heating ventilation and air conditioning systems. Ordering Procedure Using the chart below, select your requirements and substitute the underscored text below. AF..L..R..40..D..A Example: If your requirement is for a 8 (3mm) dia. plain core duct, 6m long, non fire rated, the ordering code would be: AF..6..S..40..08..P (When ordering it is not necessary to include the periods (..)). Type Length (m) "L" Fire Rating "R" Diameter (inch) "D" Noise Attenuation "A" 3m 6m Standard Fire Rated Inch (mm) Acoustic Plain AF 3 6 S F 06 (152) A P " 3 6 S F 08 (3) A P " 3 6 S F (254) A P " 3 6 S F 12 (4) A P " 3 6 S F 14 (355) A P " 3 6 S F 16 (406) A P " 3 6 S F 18 (457) A P " 3 6 S F (8) A P " 3 6 S F 22 (558) A P " 3 - S F 24 (609) A P Page. 1

5. AF FABRIFLEX R1.0 DUCT Performance 00 0 Static Pressure (Pa) /m Acoustical Plain } 0mm dia Acoustical Plain } 2mm dia Acoustical Plain } 0mm dia Acoustical Plain } 3mm dia } 400mm dia Acoustical Plain Acoustical Plain } 4mm dia 0 0 0 0 00 00 00 4000 These graphs are for selection only and should not be used for commissioning. Ratings Maximum air Velocity m/s plain core 15 m/s acoustic core Airflow temperature range - 0 C to 80 0 C Maximum working pressure/ vacuum Refer to graph in this section. Page. 2

FABRIFLEX R1.0 DUCT 5. AF Acoustic properties Fabriflex duct has sound attenuation properties. The sound attenuation graph below is based on the NATA Report No. 413-82. The testing was in accordance with BS4718/1971 methods of test for silencers for air distribution systems, Section 2.3 diffuse field method, and Air Diffusion Council Test Code - FD 72. Care should be taken in estimation the attenuation from ducts of different lengths. Results are not linear. The graph shows results of tests on 3 metre lengths. These graphs are for selection only and should not be used for commissioning. Weight (g/m) 1600 10 Insulated 1400 10 10 00 900 800 Plain 700 600 0 400 0 0 0 0 0 1 0 2 0 3 400 4 0 5 600 Duct Nominal Diameter (mm) Average Static Insertion Loss (db) 40 2mm Perforated 4mm Unperforated 2mm 0 4mm 0 63 1 1252 2 3 0 4 1k 5 2k 6 4k 7 8k 8 Frequency Band (Hz) Maximum recommended working pressures 25 kpa Maximum recommended working vacuum 20 mmh2o 00 15 10 00 5 Plain 0 0 1 0 2 0 3 400 4 0 5 600 Duct Nominal Diameter (mm) 0 Plain 0 0 1 0 2 0 3 400 4 0 5 600 Duct Nominal Diameter (mm) Page. 3

ROLLFLEX DUCT 5.12 AFL Description Rollflex non-compressible duct is formed by a single ply aluminium band, helically wound and corrugated with a 4-ply folded and crimped seam. The all metal construction makes the duct virtually non-compressible. Rolllex can be easily bent by hand while retaining its basic round shape. It comes in plain, insulated and insulated acoustic forms. The insulated duct has R1.0 m 2 K/W glasswool retained by a vapour barrier sleeve. Available in 3 metre lengths only. Ordering procedure Using the chart below, select your requirements and substitute the underscored text AFL3..R..I..D..A Example: If your requirement is for a 8 (3 mm) dia. fire rated duct, the ordering code would be: AFL3..F..40..08..P (When ordering it is not necessary to include the periods [..]) Type Fire Rating "R" Insulation "I" Diameter (inch) "D" Noise Attenuation "A" Standard Fire Rated Nude core Insulated Inch (mm) Acoustic Plain AFL3 S F 00 40 06 (152) A P " S F 00 40 08 (3) A P " S F 00 40 (254) A P " S F 00 40 12 (4) A P " S F 00 40 14 (355) A P " S F 00 40 16 (406) A P " S F 00 40 18 (457) A P " S F 00 40 (8) A P Page. 4

5.12 AFL ROLLFLEX DUCT 40 Average Static Insertion Loss (db) 2mm Acoustic 2mm Non acoustic 0 0 63 1 1252 2 3 0 4 1k 5 2k 6 4k 7 8k 8 Frequency Band (Hz) Acoustic properties Insulated Rollflex duct may be supplied with small perforations in the duct core. These perforations serve to improve the acoustic properties of the duct. The duct can be supplied in either acoustic or plain form, however acoustic duct will always be insulated. The sound attenuation graph above has been based on NATA test (report No. 946-87) Performance ratings Air velocity * m/s maximum (unperforated core) * 15 m/s maximum (perforated core) Working pressure * 00 Pa maximum (unperforated core) * 00 Pa maximum (perforated core) Working vacuum * 00 Pa maximum (unperforated core) * 00 Pa maximum (perforated core) Working temperature uninsulated * 0 deg C on internal and external surface Working temperature insulated * 1 deg C on internal surface * 80 deg C on External surface Page. 5

EXTRACTAFLEX DUCT 5.14 AHE Description The Bradflo range of industrial ducting is made from a range of special purpose fabrics with a external helix. This helix is formed to clamp the fabric in a mechanical lock. No adhesives are used at all. The construction provides strength and durability to resist rough external treatment while maintaining good flexibility. Extractaflex is easy to handle and may be compressed to about 1/5th of its extended length. It is suitable for both high and low pressure applications. Ordering procedure Using the chart below, select your requirements and substitute the underscored text Type..D..L Example: If your requirement is for a AHEEHT (extra high temperature duct), 127 mm in dia. 6 m long, the ordering code would be AHEEHT..127..6 (When ordering it is not necessary to include the periods [..]) Product Size Numbers Type Diameter "D" Length "L" Millimetre Metre AHEGG 051 1- AHEYG 076 1- AHEHT 2 1- AHEEHT 127 1- AHEHD 152 1-3 1-5 1-356 1-406 1-457 1-6 1- Page. 6

5.14 AHE EXTRACTAFLEX DUCT Types of Extractaflex duct Type Description Properties AHEGG PE Green General service dust collection, AHEYG PE Yellow fume control, light abrasion, gravity feed. Temperature: - deg C - +60 deg C Type Description Properties AHEHT Flexible aluminium High temperature air and fume control including weling fumes. Temperature: - deg C - +1 deg C Type Description Properties AHEEHT Silicone grey Extremely hot air, dust and fume control Resists alkalies, ozone and fungi Temperature: - deg C - +2 deg C Type Description Properties AHEHD Tarp black Heavy duty dust collection, internal and external abrasion, gravity feed. Temperature: - deg C - +1 deg C Performance data 00 Static Pressure (Pa) /m 0 0mm dia 2mm dia 0mm dia 3mm dia 400mm dia 4mm dia 0 0 0 0 00 00 00 4000 These graphs are for selection only and should not be used for commissioning Ratings Maximum air velocity: m/s Airflow temperature: Refer description above Working pressure & vacuum: Refer chart next page. Page. 7

EXTRACTAFLEX DUCT 5.14 AHE Maximum recommended Nominal diameter mm Working pressure kpa Vacuum mm WG 51 - - 76 40 2 34 2800 127 28 2400 152 19 3 5 3 2 6 1 Chemical compatability AHEGG AHEYG AHEHT AHEEHT AHEHD AHEGG AHEYG Acetaldehyde c c c x Hydrochloric acid dilute s x s s Acetic acid dilute s c s s Hydrogen s s s s Acetone x c c x Hydrogen sulphide s c s c Acetylene gas x s x c Kerosene x c x c Aluminium hydroxide s s s s Lime (hydrated) s c s s Ammonia gas s c s s Methyl alcohol x c s s Ammonium hydroxide s c s s Methylethyl ketone x c x x Amyl alcohol x c s s Natural gas s s s s Aniline x s s x Nitric acid dilute s x s c Animal fats & oils c s c c Nitrogen s s s s Benzene x c x x Nitrobenzene c c x x Bromine gas x c s x Oxygen s s s s Butane gas x s s c Perchlorethylene x c x x Carbon dioxide s s s s Petrol x c x c Carbon monoxide s s s s Phenol x c c c Carbon tetrachloride x x x x Propane gas c s s s Cement-high alumina s s s s Sodium carbonate s c s s Cement-portland s s s s Sodium silicate s s s s Chalk (dry) s s s s Sulphur dioxide (dry) s c s c Chlorine gas x x s x Sulphuric acid dilute s x s s Chlorinated solvents c c x x Tetrahydrofuran x c x x Chloroform x x x x Toluene x c x x Citric acid s s s s Trychlorethene x c x x Crude oil c c c c Turpentine x c x x Cyclohexane x c x x Urea s s s s Diesel oil x s c c Water s c s s Ether x c x c Xylene x c x x Ethyl alcohol x c s s Ethyene glycol x c s s Formaldehyde s c c c Gypsum (dry) s s s s s - satisfactory, c - conditional, x - not suitable AHEHT AHEEHT AHEHD Page. 8

ISODEC INSULATED DUCT 5.15 AIS Construction The duct is made up of a aluminium/polyester film laminated core, incorporating a coated mechanical spring wire helix and solvent based adhesive. The duct is constructed in a way that allows it to maintain its full diameter throughout bends. When correctly installed, it offers low resistance to air flow. The glasswool insulation surrounding the duct core is encapsulated in a UV resistant and heat stabilised polyethylene sleeve or, in the case of the fire rated version, a aluminium/polyester laminated sleeve. Insulation The insulation is 40mm glasswool blanket with a nominal R value of 1.0m 2 K/W. Application Isodec has been designed for high and low pressure heating, ventilation and cooling. It is supplied in standard diameters from 127mm through 2mm in 25mm increments, and from 2mm through 0mm in mm increments. Lengths of 3m and 6m up to and including 400mm dia. The 4mm and 0mm dia. is available in 3m lengths only. Ordering Procedure Using the chart below, select your requirements and substitute the underscored text below. AIS..L..R.. 40..D..A Example: If your requirement is for a 8 (3mm) dia. fire rated, plain core duct, 6m long, the ordering code would be: AIS..6..F..40..08..P (When ordering it is not necessary to include the periods (..)). Type Length (m) "L" Rating "R" Diameter (inch) "D" Noise Attenuation "A" 3m 6m Standard Fire Inch (mm) Acoustic Plain Rated AIS 3 6 S F 05 (127) A P " 3 6 S F 06 (152) A P " 3 6 S F 07 (178) A P " 3 6 S F 08 (3) A P " 3 6 S F 09 (228) A P " 3 6 S F (254) A P " 3 6 S F 12 (4) A P " 3 6 S F 14 (355) A P " 3 6 S F 16 (406) A P " 3 6 S F 18 (457) A P " 3 - S F (8) A P Page. 9

5.15 AIS ISODEC INSULATED DUCT Performance data 00 0 Static Pressure (Pa) /m Acoustical Plain } 0mm dia Acoustical Plain } 2mm dia Acoustical Plain } 0mm dia Acoustical Plain } 3mm dia } 400mm dia Acoustical Plain Acoustical Plain } 4mm dia 0 0 0 0 00 00 00 4000 These graphs are for selection only and should not be used for commissioning Ratings Maximum Air velocity: m/s plain core 15m/s acoustic core Airflow temperature: range - 0 C to 0 C (External temperature should not exceed 80 0 C) Fire Hazard Performance Isodec Fire Rated duct achieves a zero for all indices when tested to AS15.3 in accordance with AS/NZS 1668.1-1998 Isodec also meets the requirements of AS4254-1995 and amendments when tested to AS 15.3 and UL181 Maximum Working Pressure: 20 Pa (plain core) 7 Pa (acoustic core) (When installed to Bradflo installation instructions.) Page.

ISODEC INSULATED DUCT 5.15 AIS Weight of duct Acoustic properties 1600 Weight (g/m) 40 10 1400 Insulated 10 10 00 900 800 Nude core 700 600 0 400 0 0 0 0 1 0 2 0 3 400 4 0 5 600 Duct Nominal Diameter (mm) Average Static Insertion Loss (db) 2mm dia. Perforated 2mm dia. Unperforated 0 0 63 1 1252 2 3 0 4 1k 5 2k 6 4k 7 8k 8 Frequency Band (Hz) Isodec duct has sound attenuation properties. The sound attenuation shown in the graph above has been based on NATA test, report No. 943-87 Page. 11

ACOUSTIFLEX DUCT 5.16 AIL Description The Acoustiflex range of flexible duct is manufactured using a non-woven polyester fabric with an external metal helix formed to clamp the edges of the fabric in a mechanical lock. The construction provides strength and durability while maintaining superior flexibility. The duct is lightweight and easy to handle and may be compressed to about one fifth of its length. The duct is designed for low pressure heating, ventilation and cooling where noise may be transmitted through the ductwork and for systems where heat gains or losses are not high, such as evaporative cooling. The insulation is a glasswool blanket held in place by either a UV and heat resistant polyethylene or an aluminium laminated, fire resistant sleeve. Ordering Procedure Using the chart below, select your requirements and substitute the underscored text below. AIL..L..R..40..D Example: If your requirement was for 12 (0) fire rated duct, 6m long, the ordering code would be: AIL6F4012. (When ordering it is not necessary to include the periods (..)). Product Size Numbers Type Length "L" Fire rating "R" Diameter "D" 3m 6m Standard Fire rated Inch (mm) AIL 3 6 S F 06 (1) 3 6 S F 08 (0) 3 6 S F (2) 3 6 S F 12 (0) 3 6 S F 14 (3) 3 6 S F 16 (400) 3 6 S F 18 (4) 3 - S F (0) 3 - S F 22 (5) 3 - S F 24 (600) Page. 12

5.16 AIL ACOUSTIFLEX DUCT Acoustic properties 40 Performance ratings Air velocity * m/s maximum Average Static Insertion Loss (db) 2mm dia. 0 0 63 1 1252 2 3 0 4 1k 5 2k 6 4k 7 8k 8 Frequency Band (Hz) Airflow temperature * Range 0 deg. C - 80 deg. C Working pressure * 00 Pa maximum Working vacuum * 125 Pa maximum Vapour barrier * Water vapour transmission rate at 40 deg. C and 0% relative humidity is 6.4 g/m 2 /day. Acoustiflex duct has sound attenuation properties. The sound attenuation graph above has been based on NATA test No. 945-87 Performance data Pressure Drop Pa/m 0 0 5 3 Air velocity m/sec 6 4 5 22 24 Duct Diameter (mm) 63 71 80 90 0 125 1 180 225 112 140 160 0 2 8 9 7 12 14 1618 280 315 355 400 4 0 1 0 0 00 00 000 Airvolume m3/hr These graphs are for selection only and should not be used for commissioning. Page. 13

3ZERO3 GLASSWOOL R1.0 INSULATED DUCT 5.17 A3ZD Construction The duct is made up of a polyester film laminate core, incorporating a coated mechanical spring wire helix and black, water based adhesive. The duct is constructed in a way that allows it to maintain its full diameter throughout bends. When correctly installed, it offers low resistance to air flow. The glasswool insulation surrounding the duct core is encapsulated in a aluminium/polyester film laminated sleeve. Insulation The insulation is 40mm glasswool blanket with a nominal R value of 1.0m 2 K/W. Application 3Zero3 has been designed for high and low pressure heating, ventilation and cooling. It is supplied in standard diameters from 1mm through 0mm in mm increments, and in lengths of 3m and 6m up to and including 4mm dia. The 0mm dia. duct is available in 3m lengths only. The duct meets the requirements of AS 4254-1995 and it s amendments. Ordering Procedure Using the chart below, select your requirements and substitute the underscored text below. A3ZD..L..40..D..A Example: If your requirement is for a 3mm dia. plain core duct, 6m long, the ordering code would be: A3ZD..6..40..0..P (When ordering it is not neccessary to include the periods (..)). Type Length (m) "L" Diameter (inch) "D" Noise Attenuation "A" 3m 6m metric (inch) Acoustic Plain A3ZD 3 6 1 (6") A P " 3 6 0 (8") A P " 3 6 2 (") A P " 3 6 0 (12") A P " 3 6 3 (14") A P " 3 6 400 (16") A P " 3 6 4 (18") A P " 3-0 (") A P Page. 14

5.17 A3ZD 3ZERO3 GLASSWOOL R1.0 INSULATED DUCT Performance data 00 0 Static Pressure (Pa) Acoustical Plain } 0mm dia Acoustical Plain } 2mm dia Acoustical Plain } 0mm dia Acoustical Plain } 3mm dia } 400mm dia Acoustical Plain Acoustical Plain } 4mm dia 0 0 0 0 00 00 00 4000 These graphs are for selection only and should not be used for commissioning. Weight 1600 Weight (g/m) Insulated Acoustic properties 40 10 1400 10 10 00 900 800 700 600 0 400 0 0 Plain 0 0 1 0 2 0 3 400 4 0 5 600 Duct Nominal Diameter (mm) Ratings Maximum air velocity * m/s Average Static Insertion Loss (db) 2mm Perforated 2mm Unperforated 0 0 63 1 1252 2 3 0 4 1k 5 2k 6 4k 7 8k 8 Frequency Band (Hz) Airflow temperature * Range: - deg C - +80 deg C Working pressure * 20 Pa (When installed to Bradflo installation instructions) Fire hazard performance This duct meets the requirements of the Building Code of Australia and AS4254-1995 when tested to AS15.3 and UL181. The duct also meets the requirements of AS/NZS1668-1998 when tested to AS4254-1995. Page. 15

ALUDEC NUDE CORE DUCT 5.18 AAL Construction The duct is made up of a aluminium/polyester film laminated core, incorporating a coated mechanical spring wire helix and solvent based adhesive. The duct is constructed in a way that allows it to maintain its full diameter throughout bends. When correctly installed, it offers low resistance to air flow. Application Aludec has been designed for high and low pressure heating, ventilation and cooling. It is supplied in standard diameters from 127mm through 2mm in 25mm increments, and from 2mm through 0mm in mm increments. Lengths of 3m and 6m up to and including the 400mm dia. The 4mm and 0mm dia. is available in 3m lengths only. Ordering Procedure Using the chart below, select your requirements and substitute the underscored text below. Type AAL..L..00..D Example: If your requirement is for a 8 (3mm) dia. uninsulated duct, 6m long, the ordering code would be: AAL..6..00..08 (When ordering it is not necessary to include the periods (..)). Product Size Numbers Type Length "L" Diameter "D" 3m 6m Inch (mm) AAL 3 6 05 (127) 3 6 06 (1) 3 6 07 (178) 3 6 08 (3) 3 6 09 (228) 3 6 (254) 3 6 12 (4) 3 6 14 (355) 3 6 16 (406) 3-18 (457) 3 - (8) Page. 16

5.18 AAL ALUDEC NUDE CORE DUCT Performance data 00 0 Static Pressure (Pa) /m Acoustical Plain } 0mm dia Acoustical Plain } 2mm dia Acoustical Plain } 0mm dia Acoustical Plain } 3mm dia } 400mm dia Acoustical Plain Acoustical Plain } 0 0 0 0 00 00 00 4000 These graphs are for selection only and should not be used for commissioning. Weight 600 0 400 Vacuum (Pa) 0 0 0 0 06" 8" 1 " 2 12" 3 14" 4 16" 5 18" 6 Duct diameter Ratings Maximum air velocity * m/s Airflow temperature * Range: - deg C - +1 deg C Working pressure * 20 Pa (When installed to Bradflo installation instructions) Fire Hazard Performance This duct meets the requirements of the Building Code of Australia and AS 4254-1995 and it s amendments when tested to AS15.3 and UL181. This duct has achieved a zero for all four of the indices when tested to AS 15.3 Page. 17

3ZER03 POLYESTER R0.6 INSULATED DUCT 5. A3ZDP Construction The duct is made up of a polyester film laminate core, incorporating a coated mechanical spring wire helix and black, water based adhesive. The duct is constructed in a way that allows it to maintain its full diameter throughout bends. When correctly installed, it offers low resistance to air flow. The polyester insulation surrounding the duct core is encapsulated in a metalised polyester film, laminated sleeve. Insulation The insulation is 35mm polyester blanket with a nominal R value of 0.6 m 2 W/K. Application 3Zero3 Poly has been designed for high and low pressure heating, ventilation and cooling. It is supplied in standard diameters from 1mm through 0mm in mm increments, and in lengths of 3m and 6m up to and including 400mm dia. The 4mm and 0mm dia. duct is available in 3m lengths only. The duct complies with the requirements of AS 4254-1995. Ordering Procedure Using the chart below, select your requirements and substitute the underscored text below. A3ZD..L..P35..D..P Example: If your requirement is for a 0mm dia. duct, 6m long, the ordering code would be: A3ZD..6..P35..0P (When ordering it is not necessary to include the periods (..)). Type Length (m) "L" Diameter (inch) "D" Noise Attenuation "A" 3m 6m metric (inch) Plain A3ZD 3 6 1 (6") P " 3 6 0 (8") P " 3 6 2 (") P " 3 6 0 (12") P " 3 6 3 (14") P " 3 6 400 (16") P " 3 6 4 (18") P " 3-0 (") P Page. 18

5. A3ZDP 3ZER03 POLYESTER R0.6 INSULATED DUCT Performance 00 0 Static Pressure (Pa) /m Acoustical Plain } 0mm dia Acoustical Plain } 2mm dia Acoustical Plain } 0mm dia Acoustical Plain } 3mm dia } 400mm dia Acoustical Plain Acoustical Plain } 4mm dia 0 0 0 0 00 00 00 4000 These graphs are for selection only and should not be used for commissioning. Weight Weight (g/m) 1600 10 1400 10 10 00 900 800 700 600 0 400 0 0 (Polyester insulation) mm Insulated Plain 35 mm Insulated 0 0 1 0 2 0 3 400 4 0 5 600 Duct Nominal Diameter (mm) Working vacuum Vacuum (Pa) 600 0 400 0 0 0 0 06" 8" 1 " 2 12" 3 14" 4 16" 5 18" 6 Duct diameter Ratings Maximum Air velocity m/s Airflow temperature range - 0 C to 80 0 C Maximum Working Pressure 20 Pa When installed to Bradflo installation instructions. Page. 19 Fire Hazard Performance This duct meets the requirements of the Building Code of Australia and AS 4254-1995 and it s amendments when tested to AS15.3 and UL181. The duct also meets the requirements of AS/NZS 1668.1-1998 when tested in accordance with AS 4254-1995.

BC FLEX GLASSWOOL R1.0 INSULATED DUCT 5.21 ABCD Construction The duct is made up of a polyester film laminate core, incorporating a coated mechanical spring wire helix and black, water based adhesive. The duct is constructed in a way that allows it to maintain its full diameter throughout bends. When correctly installed, it offers low resistance to air flow. The glasswool insulation surrounding the duct core is encapsulated in a UV resistant and heat stabilised polyethylene sleeve. Insulation The insulation is 40mm glasswool blanket with a nominal R value of 1.0m 2 K/W. Application BC Flex has been designed for high and low pressure heating, ventilation and cooling. It is supplied in standard diameters from 1mm through 4mm in mm increments, and in lengths of 3m and 6m up to and including 400mm dia. The 4mm and 0mm dia. duct is available in 3m lengths only. Ordering Procedure Using the chart below, select your requirements and substitute the underscored text below. ABCD..L..S..38..D Example: If your requirement is for a 8 (3mm) dia. duct, 6m long with glasswool insulation, the ordering code would be: ABCD..6..S..38..08 (When ordering it is not necessary to include the periods (..)). Type Length (m) "L" Diameter (inch) "D" 3m 6m metric (inch) ABCD 3 6 1 (6") " 3 6 0 (8") " 3 6 2 (") " 3 6 0 (12") " 3 6 3 (14") " 3 6 400 (16") " 3-4 (18") " 3-0 (") Page.

5.21 ABCD BC FLEX GLASSWOOL R1.0 INSULATED DUCT Performance data 00 0 Static Pressure (Pa) /m Acoustical Plain } 0mm dia Acoustical Plain } 2mm dia Acoustical Plain } 0mm dia Acoustical Plain } 3mm dia } 400mm dia Acoustical Plain Acoustical Plain } 0 0 0 0 00 00 00 4000 These graphs are for selection only and should not be used for commissioning. Weight 600 0 400 Vacuum (Pa) 0 0 0 0 06" 8" 1 " 2 12" 3 14" 4 16" 5 18" 6 Duct diameter Ratings Maximum air velocity * m/s Airflow temperature * Range: - deg C - +80 deg C Working pressure * 20 Pa (When installed to Bradflo installation instructions) Page. 21

BC FLEX POLYESTER R0.6 INSULATED DUCT 5.22 ABCD Construction The duct is made up of a polyester film laminate core, incorporating a coated mechanical spring wire helix and black, water based adhesive. The duct is constructed in a way that allows it to maintain its full diameter throughout bends. When correctly installed, it offers low resistance to air flow. The polyester insulation surrounding the duct core is encapsulated in a UV resistant and heat stabilised polyethylene sleeve. Insulation The insulation is 35mm polyester blanket with a nominal R value of 0.6 m 2 K/W. Application BC Flex has been designed for high and low pressure heating, ventilation and cooling. It is supplied in standard diameters from 1mm through 4mm in mm increments, and in lengths of 3m and 6m up to and including 0mm dia. Ordering Procedure Using the chart below, select your requirements and substitute the underscored text below. ABCD..L..P..35..D Example: If your requirement is for a 8 (3mm) dia. duct, 6m long with glasswool insulation, the ordering code would be: ABCD..6..P..35..08 (When ordering it is not necessary to include the periods (..)). Type Length (m) "L" Diameter (inch) "D" 3m 6m metric (inch) ABCD 3 6 1 (6") " 3 6 0 (8") " 3 6 2 (") " 3 6 0 (12") " 3 6 3 (14") " 3 6 400 (16") " 3 6 4 (18") " 3 6 0 (") Page. 22

5.22 ABCD BC FLEX POLYESTER R0.6 INSULATED DUCT Performance data 00 0 Static Pressure (Pa) /m Acoustical Plain } 0mm dia Acoustical Plain } 2mm dia Acoustical Plain } 0mm dia Acoustical Plain } 3mm dia } 400mm dia Acoustical Plain Acoustical Plain } 0 0 0 0 00 00 00 4000 These graphs are for selection only and should not be used for commissioning. Weight 600 0 400 Vacuum (Pa) 0 0 0 0 06" 8" 1 " 2 12" 3 14" 4 16" 5 18" 6 Duct diameter Ratings Maximum air velocity * m/s Airflow temperature * Range: - deg C - +80 deg C Working pressure * 20 Pa (When installed to Bradflo installation instructions) Page. 23

3ZER03 POLYESTER R1.0 INSULATED DUCT 5.25 A3ZDP Construction The duct is made up of a polyester film laminate core, incorporating a coated mechanical spring wire helix and black, water based adhesive. The duct is constructed in a way that allows it to maintain its full diameter throughout bends. When correctly installed, it offers low resistance to air flow. The polyester insulation surrounding the duct core is encapsulated in a metalised polyester film, laminated sleeve. Insulation The insulation is mm polyester blanket with a nominal R value of 1.0 m 2 K/W Application 3Zero3 Poly has been designed for high and low pressure heating, ventilation and cooling. It is supplied in standard diameters from 1mm through 0mm in mm increments, and in lengths of 3m and 6m up to and including 400mm dia. The 4mm and 0mm dia. duct is available in 3m lengths only. Ordering Procedure Using the chart below, select your requirements and substitute the underscored text below. A3ZD..L..P..D Example: If your requirement is for a 0mm dia. duct, 6m long, the ordering code would be: A3ZD..6..P..0 (When ordering it is not necessary to include the periods (..)). Type Length (m) "L" Diameter (inch) "D" Noise Attenuation "A" 3m 6m metric (inch) Plain A3ZD 3 6 1 (6") P " 3 6 0 (8") P " 3 6 2 (") P " 3 6 0 (12") P " 3 6 3 (14") P " 3 6 400 (16") P " 3-4 (18") P " 3-0 (") P Page. 24

5.25 A3ZDP 3ZER03 POLYESTER R1.0 INSULATED DUCT Performance 00 0 Static Pressure (Pa) Acoustical Plain } 0mm dia Acoustical Plain } 2mm dia Acoustical Plain } 0mm dia Acoustical Plain } 3mm dia } 400mm dia Acoustical Plain Acoustical Plain } 4mm dia 0 0 0 0 00 00 00 4000 These graphs are for selection only and should not be used for commissioning. Weight Weight (g/m) 1600 10 1400 10 10 00 900 800 700 600 0 400 0 0 (Polyester insulation) mm Insulated Plain 35 mm Insulated 0 0 1 0 2 0 3 400 4 0 5 600 Duct Nominal Diameter (mm) Working vacuum Vacuum (Pa) 600 0 400 0 0 0 0 06" 8" 1 " 2 12" 3 14" 4 16" 5 18" 6 Duct diameter Ratings Maximum Air velocity m/s Airflow temperature range - 0 C to 80 0 C Maximum Working Pressure 20 Pa When installed to Bradflo installation instructions. Page. 25

POLYFAB R1.0 DUCT 5.26 AFPB Description Polyfab ducting is made from a black laminated fabric with an external metal helix formed to clamp the edges of the fabric in a mechanical lock. No adhesives are used. The metal helix gives the duct strength durability and scuff resistance. The duct is insulated with a polyester blanket (R value of 1.0 m 2 W/K) which is protected by a outer vapourbarrier sleeve. The duct assembly is lightweight, easy to handle and extremely flexible, Fabriflex ducting can be compressed to less than a quarter of its normal extended length. The duct is suitable for both high and low pressure heating ventilation and air conditioning systems. Ordering Procedure Using the chart below, select your requirements and substitute the underscored text below. AFPB..L..P..60..D..A Example: If your requirement is for a 8 (3mm) dia. plain core duct, 6m long, non fire rated, the ordering code would be: AFPB..6..P..60..0..P (When ordering it is not necessary to include the periods (..)). Type Length (m) "L" Diameter "D" Noise Attenuation "A" 3m 6m (Inch) mm Plain AFPB 3 6 (6) 1 P " 3 6 (8) 0 P " 3 6 () 2 P " 3 6 (12) 0 P " 3 6 (14) 3 P " 3 6 (16) 400 P " 3 - (18) 4 P " 3 - () 0 P " " Page. 24

5.26 AFPB POLYFAB R1.0 DUCT Performance 00 0 Static Pressure (Pa) /m Acoustical Plain } 0mm dia Acoustical Plain } 2mm dia Acoustical Plain } 0mm dia Acoustical Plain } 3mm dia } 400mm dia Acoustical Plain Acoustical Plain } 4mm dia 0 0 0 0 00 00 00 4000 These graphs are for selection only and should not be used for commissioning. Ratings Maximum air Velocity m/s plain core 15 m/s acoustic core Airflow temperature range - 0 C to 80 0 C Maximum working pressure/ vacuum Refer to graph in this section. Page. 25

POLYFAB R1.0 DUCT 5.26 AFPB Acoustic properties Fabriflex duct has sound attenuation properties. The sound attenuation graph below is based on the NATA Report No. 413-82. The testing was in accordance with BS4718/1971 methods of test for silencers for air distribution systems, Section 2.3 diffuse field method, and Air Diffusion Council Test Code - FD 72. Care should be taken in estimation the attenuation from ducts of different lengths. Results are not linear. The graph shows results of tests on 3 metre lengths. These graphs are for selection only and should not be used for commissioning. Weight (g/m) 1600 10 Insulated 1400 10 10 00 900 800 Plain 700 600 0 400 0 0 0 0 0 1 0 2 0 3 400 4 0 5 600 Duct Nominal Diameter (mm) Average Static Insertion Loss (db) 40 2mm Perforated 4mm Unperforated 2mm 0 4mm 0 63 1 1252 2 3 0 4 1k 5 2k 6 4k 7 8k 8 Frequency Band (Hz) Maximum recommended working pressures 25 kpa Maximum recommended working vacuum 20 mmh2o 00 15 10 00 5 Plain 0 0 1 0 2 0 3 400 4 0 5 600 Duct Nominal Diameter (mm) 0 Plain 0 0 1 0 2 0 3 400 4 0 5 600 Duct Nominal Diameter (mm) Page. 26

ISODEC POLY INSULATED DUCT 5.27 AIS Construction The duct is made up of a aluminium/polyester film laminated core, incorporating a coated mechanical spring wire helix and solvent based adhesive. The duct is constructed in a way that allows it to maintain its full diameter throughout bends. When correctly installed, it offers low resistance to air flow. The polyester insulation surrounding the duct core is encapsulated in a UV resistant and heat stabilised polyethylene sleeve or, in the case of the fire rated version, a aluminium/polyester laminated sleeve. Insulation The insulation is 35mm polyester blanket with a nominal R value of 0.6m 2 K/W. Application Isodec has been designed for high and low pressure heating, ventilation and cooling. It is supplied in standard diameters from 127mm through 2mm in 25mm increments, and from 2mm through 0mm in mm increments. Lengths of 3m and 6m up to and including 400mm dia. The 4mm and 0mm dia. is available in 3m lengths only. Ordering Procedure Using the chart below, select your requirements and substitute the underscored text below. AIS..L..R..P.. 35..D..P Example: If your requirement is for a 8 (3mm) dia. fire rated, plain core duct, 6m long, the ordering code would be: AIS..6..F..P..35..08..P (When ordering it is not necessary to include the periods (..)). Type Length (m) "L" Rating "R" Diameter (inch) "D" Noise Attenuation "A" 3m 6m Standard Fire Rated Inch (mm) Acoustic Plain AIS 3 6 S F 05 (127) P " 3 6 S F 06 (152) P " 3 6 S F 07 (178) P " 3 6 S F 08 (3) P " 3 6 S F 09 (228) P " 3 6 S F (254) P " 3 6 S F 12 (4) P " 3 6 S F 14 (355) P " 3 6 S F 16 (406) P " 3 6 S F 18 (457) P " 3 - S F (8) P Page. 29

5.27 AIS ISODEC POLY INSULATED DUCT Performance data 00 0 Static Pressure (Pa) /m Acoustical Plain } 0mm dia Acoustical Plain } 2mm dia Acoustical Plain } 0mm dia Acoustical Plain } 3mm dia } 400mm dia Acoustical Plain Acoustical Plain } 4mm dia 0 0 0 0 00 00 00 4000 These graphs are for selection only and should not be used for commissioning Ratings Maximum Air velocity: m/s plain core 15m/s acoustic core Airflow temperature: range - 0 C to 0 C (External temperature should not exceed 80 0 C) Fire Hazard Performance Isodec Fire Rated Poly duct achieves a zero for all indices when tested to AS15.3 in accordance with AS/NZS 1668.1-1998 Isodec Poly also meets the requirements of AS4254-1995 and amendments when tested to AS 15.3 and UL181 Maximum Working Pressure: 20 Pa (plain core) 7 Pa (acoustic core) (When installed to Bradflo installation instructions.) Page.

DIRECTIONAL DIFFUSERS ACTL ACTB The square, cone-type directional diffuser has been designed to meet modern building requirements. Standard frame configurations are available which are suitable for T-bar, tile or plaster ceilings. The core section is removable for easy installation and maintenance. Directional diffusers can be manufactured with a variety of blow patterns to suit any application. Sizes and colours are limited only by the imagination. ACTL, ACTB ACTB ACTL PERFORATED DIFFUSERS Perforated diffusers are designed to fit most suspended ceilings. The perforated plate is easily removed from the fixed frame for fitting and cleaning. A lockable version is also available. APD, APDE, APDEL APDEL APD Circular perforated supply air diffusers are designed for draught free conditions normally required in schools, offices and hotels. APR The Environment 00 is an exclusive range of air distribution devices designed to supply a draught free, quiet and pleasant atmosphere. The Environment 00 can be supplied as a diffuser only or as a complete kit featuring an acoustic plenum and air measuring station. This product can also be used as a matching return or exhaust air grille. APME, APMF, APM APM APR HOME

CIRCULAR DIFFUSERS ACDSC Circular cone diffusers are designed with multiple cones which are fully adjustable to vary the discharge pattern. This unique style of diffuser is ideal for large areas requiring state of the art airflow and appearance, for instance, in lobbies, foyers and arenas. ACDSC, ACDRA ACDRA ACDRA Round ceiling diffusers are used primarily for supply air situations. The core, which controls both air pattern and air volume, is fully adjustable. These diffusers are also fitted with spigots to suit flexible duct. This product can provide an attractive alternative in bathroom exhaust applications. ARCD ARCD JET DIFFUSERS AJD ADJD Jet diffusers are designed for use in large areas such as sport centers, theatres, entertainment and industrial areas. They are suitable for airconditioning evaporative cooling or ventilation applications. Air flow is easily adjusted from a jet to a diffused pattern and the direction adjusted by moving the core through an arc. New to Bradflo is the flush mounted low profile jet style diffuser, ideal for ventilating smaller areas such as cafe s, show rooms and retail outlets. AJA AJS AJD, AJA, AJS, AJAS, ADJD AJAS HOME

LINEAR SLOT DIFFUSERS ALDU Linear slot diffusers are an extremely versatile product and can be used to supply or return air. There are two choices of blade profiles that are adjustable to offer air pattern variations. These diffusers are supplied in a range of one to eight slots. ALDU, ALDA ALDA PLENUM DIFFUSERS AABS AABD Plenum diffusers are designed to suit ceiling T-Bar systems and are suitable for either perimeter or centre zone air-conditioning. This is due to the diffuser s fully adjustable air pattern characteristics. An integral component of this system is the ability to attach the diffuser to recessed fluorescent light fittings. Insulated plenums are also available. AVPA, AABS, AABD AVPA BAR GRILLES ASG ASGF Slimline bar grilles offer an attractive alternative for sidewall, sill or floor mounted air diffusion requirements. They can be used either as supply or return grilles and are available in fixed or removable core. Bradflo offers six different core profiles with each delivering a distinctive air pattern. Slimline bar grilles are also available as a trafficable product. ASG ASG, ASGF HOME

VARIABLE DEFLECTION GRILLES AUR AURC AUS2 Variable deflection grilles, also known as sidewall registers, are designed for mounting directly into a bulkhead or are connected to ductwork. Curved face options are available for mounting into circular or oval ductwork with removable core models providing access for maintenance and cleaning. AUR, AURR, AUS2, AURC ACB ACB Curved blade grilles, referred to as multi-directional outlets, are designed for ceiling mounted supply air situations. They are especially suited for evaporative cooling systems. These grilles are available in one, two, three or four-way blow patterns and are designed to provide the most efficient operation at the lowest possible sound level. ACB HALF CHEVRON GRILLES ARG Half chevron grilles are an attractive wall mounted return air product. A range of blade profiles are available including standard and slimline options. These grilles can be manufactured with hinged or removable core to accommodate a wide variety of filters. ARG Half chevron grilles can also be utilised as a decorative grille or infill panels. ARG ARG LOUVRES Both horizontal and vertical louvres are available in wide varieties of profiles that cover all applications including weather proof, double rain trap and storm proof. AWL Bradflo louvre systems can also be used as an architectural decorative cladding in any shape or size and are ideal for the construction of penthouses and enclosures. AWL HOME

EGG CRATE GRILLES AAECSNA AEC Egg crate grilles are designed for use in exhaust or return air situations and may be mounted in walls or ceilings. Hinged and removable core models are available as standard and provide easy access to filters, fans or other equipment. The versatile egg crate grille can also be supplied as panels for infill applications and again sizes and colours are limited only by your imagination. AEC, AECL, AEHF, AECOR, AEGGCRT AEHF AECRC AECOR AEGGCRT AIR TRANSFER GRILLES Aluminium door grilles have horizontally mounted blades that are firmly fixed into a frame. To remain aesthetically pleasing, an adjustable rear frame covers the opening of the grille on the opposite side of the door. A slimline channel frame is also available. ADDR3 ATJ AADR, ADDR3 The acoustic transfer grille is a rectangular air transfer device for direct wall mounting. The grille is double sided and is identical on both sides. The construction of the grille allows high airflow while minimising sound transmission. AADR ATJ HOME

FLOOR REGISTERS ASFR Floor registers are made of a sturdy all-steel construction, suiting both domestic and commercial applications. A wide range of standard colours and sizes are available upon request. ASFR ASFR FLOOR GRILLES ASFF AHDF Heavy-duty floor grilles are constructed of an expanded steel mesh core with a fully welded steel frame. They may be used as heavy-duty exhaust grilles for underground car parks. Floor grilles may also be used for return air situations. Balancing dampers can be fitted behind the grille. AHDF Computer floor grilles are an attractive slimline bar grille, reinforced for trafficable situations. This product can be supplied as a grille in a frame or in continuous form. Six blade profiles are available offering a variety of air patterns. Many colours are available on request. ASFF, AAFF, ASTF, ASTFI AAFF ASTFI HOME

ACK AMU PLENUMS FITTINGS AND ACCESSORIES End of line or plenum mounted measuring devices, in conjunction with balancing dampers, offer a simple and accurate method of measuring the airflow. These measuring devices are compatible with a wide range of Bradflo diffusion products. AMU, ARU ASSD AOBD Bradflo manufactures a full range of dampers including Opposed Blade, Stream Splitter and Equalising Grid. Our spigot range includes Bellmouth Spigots with or without Butterfly Dampers as well as Straight Spigots and Branch Takeoffs. AOBD, AHSP, ACK, ASSD PLENUMS Plenum Boxes are manufactured to suit the entire Bradflo diffuser and grille range. Plenums can be supplied un-insulated or with acoustic and thermal insulation. Air measuring devices and/or dampers can be factory fitted or supplied separately. ADC, ADCI, ADE, ASE ADC VOLUME CONTROL DAMPERS Volume control dampers are available in either opposed blade or parallel blade configurations. Manufactured from heavy duty aluminium extrusions, volume control dampers may be configured for manual or motorised operation and there is a choice of either gear or linkage drive. VCD AVCD, DVCD HOME

AF AIS AIR CONDITIONING DUCTS Bradflo s extensive range of air conditioning ducts come with a variety of features for different applications. Nude core is available for general ventilation, heating and cooling. Duct core can then be insulated with polyester or bio-soluble glass wool. AIS_F Ducts are manufactured to meet the requirements of the building code of Australia and all relevant Australian standards and statutory requirements. AIS, AF, A3ZD, AIS_F AAL A3ZD A3ZD INDUSTRIAL DUCT AAL Extractaflex has been specially designed for industrial use in the removal of dust, small particles, fumes and other atmospheric contaminants. The Extractaflex is manufactured from a wide range of materials which offer resistance to heat, abrasion and chemical atmospheres. AHE AHE AFL Rollflex is a versatile general purpose flexible duct which can be supplied nude or insulated and sleved. AFL SKYLIGHT DUCT AHF Skylight duct is manufactured with an ultra reflective inner surface, which transfers maximum levels of light from the roof dome to the room. The duct can be configured in round, square and rectangular shapes and sizes to suit individual customer needs. AHF HOME

HOME COMPANY PROFILE The Bradflo Head Office and Manufacturing facility is situated on a 2.158 hectare site in Albury, on the NSW-Victoria border. It is ideally located on the major transport link between Sydney and Melbourne, and has good transport access to all major Australian markets. Bradflo presently employs approx. 1 people in the Albury factory and Administration centre. Bradflo employs an further people in its sales branch network throughout Australia. Bradflo manufactures and markets a complete range of air distribution products (refer Product Summary). PRODUCT SUMMARY

HOME MANUFACTURING Factory and administration centre 7,000 sq. metres. Complete range of specialised machinery including: Automated power coating line. DEC, Fabriflex and Rollflex duct core machines. Semi-automated duct insulation and sleeving machines. Plasma sheet metal cutting facility. Steel coil slitting and cut to length line. Automated coil fed collar making machine. CNC Turret punch. Polyurethane spray booth. Insulated sandwich panel manufacturing. Robotic welding cell. Aluminium eggcrate manufacturing cell. New products and equipment are continually being reviewed and added as customer needs arise.

HOME NATIONAL SALES AND DISTRIBUTION Bradflo also has an extensive network of distributors and is expanding overseas. Locations of these sales branches plus seven of our major distributors are shown below. Darwin Brisbane Adelaide Canberra Albury Melbourne Newcastle Sydney Wollongong Auckland Hobart Wellington Christchurch HOW TO CONTACT US

HOME TECHNICAL AND SUPPORT SALES SUPPORT Administration & Factory Garland Avenue, Albury 2640 Tel: (02) 6058 6900 Fax: (02) 6058 6928 Adelaide Reese Avenue, Richmond 33 Tel: (08) 8152 0522 Fax: (08) 8152 0533 Brisbane 3/41 Lysaght Street, Acacia Ridge 41 Tel: (07) 3216 9611 Fax: (07) 3216 9477 Canberra 1B, 187 Gladstone Street, Fyshwick 2609 Tel: (02) 6239 3400 Fax: (02) 6239 3404 Melbourne 77 Overseas Drive, Noble Park 3174 Tel: (03) 9795 7744 Fax: (03) 9795 7799 Newcastle 3/69 Munibung Road, Cardiff 2285 Tel: (02) 4954 0623 Fax: (02) 4954 2799 Riverina 943 Metry Street, Albury 2640 Tel: (02) 6058 6944 Fax: (02) 6040 6035 Sydney 7 Percy Street, Auburn 2144 Tel: (02) 9735 1414 Fax: (02) 9735 14 Web Address: www.bradflo.com.au