Empirical study of heat transfer at input area of turbojet blades

Similar documents
Empirical assessment of heat transmission and pressure loss in turbojet blades

Thermo-Hydraulic Performance of a Roughened Square Duct Having Inclined Ribs with a Gap on Two Opposite Walls

Augmented Heat Transfer in Square ducts with Transverse and Inclined Ribs with and without a gap

Heat Transfer Enhancement of Solar Air Heater By Using Artificial Roughness double inclined ribs

Effect of rib height on heat transfer and friction factor in a square channel roughened by inclined ribs with a gap

Comparative study of Different Geometry of Ribs for roughness on absorber plate of Solar Air Heater -A Review

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 06, 2015 ISSN (online):

ARTICLE IN PRESS. K.R. Aharwal a,, B.K. Gandhi b, J.S. Saini b

Experimental Heat transfer study of Turbulent Square duct flow through V type turbulators

Exergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness

Computational Fluid Dynamics Based Analysis of Angled Rib Roughened Solar Air Heater Duct

Thermo Hydraulic Performance of Solar Air Heater by Using Double Inclined Discrete Rib Roughened Absorber Plate

W-Discrete Rib for Enhancing the Thermal Performance of Solar Air Heater

Effect of roughness shape on heat transfer and flow friction characteristics of solar air heater with roughened absorber plate

A Computational Fluid Dynamics Investigation of Solar Air Heater Duct Provided with Inclined Circular Ribs as Artificial Roughness

Numerical Investigation of Heat Transfer and Fluid Flow Characteristics of Roughened Solar Air Heater Duct

EFFECT OF BAFFLES GEOMETRY ON HEAT TRANSFER ENHANCEMENT INSIDE CORRUGATED DUCT

COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF A V-RIB WITH GAP ROUGHENED SOLAR AIR HEATER

Experimental investigation of heat transfer augmentation in triangular duct with rectangular wing

Numerical and Experimental Investigation of Heat Transfer Using Discrete Ribs

Experimental Validation of Heat Transfer Enhancement in plate Heat Exchanger with Non Conventional Shapes of Rib

EFFECT OF STAGGERED RIB LENGTH ON PERFORMANCE OF SOLAR AIR HEATER USING V-RIB WITH SYMMETRICAL GAP AND STAGGERED RIB

Performance evaluations of two pass solar air heater using 60⁰ inclinedvshaped ribs on absorber plate

HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF COMPOUND TURBULATORS IN RECTANGULAR DUCTS OF SOLAR AIR HEATER

NUMERICAL HEAT TRANSFER ENHANCEMENT IN SQUARE DUCT WITH INTERNAL RIB

FLOW AND HEAT TRANSFER ANALYSIS OF VARIOUS RIBS FOR FORCED CONVECTION HEAT TRANSFER

ENHANCEMENT OF HEAT TRANSFER FOR AIR FLOW THROUGH A DUCT WITH VARIOUS RIBS

CFD Analysis for Thermal Behavior of Turbulent Channel Flow of Different Geometry of Bottom Plate

Numerical Heat Transfer Study of Turbulent Square Duct Flow through W-Type Turbulators

INTERNATIONAL JOURNAL OF SCIENTIFIC & TECHNOLOGY RESEARCH VOLUME 5, ISSUE 09, SEPTEMBER 2016 ISSN

Experimental analysis of heat transfer performance on different ribs shapes in forced convection

"Experimental investigation of heat transfer enhancement by u-shaped Turbulator"

International Journal of Scientific & Engineering Research, Volume 6, Issue 5, May ISSN

Forced Convection Heat Transfer Augmentation from Ribbed Surface

Chapter 3 NATURAL CONVECTION

Outlines. simple relations of fluid dynamics Boundary layer analysis. Important for basic understanding of convection heat transfer

Department of Mechanical Engineering, M.A.C.T. (R.E.C.), Bhopal , India b. Received 15 December 2000; accepted 15 January 2001

EFFECT OF DIFFERENT PARAMETERS ON THE PERFORMANCE OF RIB ROUGHNESS SOLAR DUCT

Heat Augmentation Using Non-metallic Flow Divider Type Inserts in Forced Convection

Numerical Study of the Three-dimensional Flow in a Flat Plate Solar Collector with Baffles

Experimental Investigation of Forced Convection Heat Transfer Augmentation from a Dimpled Surface

NUMERICAL SIMULATION OF FLOW THROUGH TURBINE BLADE INTERNAL COOLING CHANNEL USING COMSOL MULTIPHYSICS

EXPERIMENTAL STUDY OF DEVELOPING TURBULENT FLOW AND HEAT TRANSFER IN RIBBED CONVERGENT/DIVERGENT RECTANGULAR DUCTS

Department of Mechanical Engineering, Indian Institute of Technology, Mumbai , Bombay Powai, India

CFD based flow and heat transfer analysis of various ribs in solar air heater duct by continuous ribs on absorber plate

CFD Analysis of Forced Convection Flow and Heat Transfer in Semi-Circular Cross-Sectioned Micro-Channel

Review of Roughness Enhancement of Solar Air Heaters having Different Rib Roughness Geometries on Absorber Plate

Heat transfer characteristics in forced convection through a rectangular channel with 60 tilted staggered ribs

International Journal of Advanced Engineering Technology E-ISSN

Lecture 30 Review of Fluid Flow and Heat Transfer

CFD Analysis & Experimental Investigation to improve Heat Transfer Enhancement in flat plate with W Ribs

Heat Transfer Enhancement Through Perforated Fin

Thermal Nanofluids flow in Corrugated Facing Step - A Review

Heat Transfer Augmentation through Electric Fan Heater Using Computational Fluid Dynamics

Laminar Forced Convection and Heat Transfer Characteristics in a Square Channel Equipped with V-Wavy Surface

CFD Analysis on Flow Through Plate Fin Heat Exchangers with Perforations

Experimental Analysis of Heat Transfer Enhancement over Dimpled Surface on One Side of Plate

A REVIEW OF HEAT TRANSFER AND LAMINAR FLOW IN A MICROCHANNEL

Theoretical prediction of performance of Single and Double pass solar air heaters with artificial roughened absorber plates

Experimental Investigations on the Local Distribution of wall static pressure coefficient Due To an Impinging Slot Air Jet on a Confined Rough Surface

EXPERIMENTAL STUDY OF DEVELOPING TURBULENT FLOW AND HEAT TRANSFER IN RIBBED CONVERGENT / DIVERGENT RECTANGULAR DUCTS by

Table of Contents. Foreword... xiii. Preface... xv

Thermo-Hydraulic performance of Internal finned tube Automobile Radiator

Experimentation and Performance Evaluation of Heat Exchanger Using Z-Ribs

Thermo-Fluid Performance of a Vapor- Chamber Finned Heat Sink

NUMERICAL SIMULATION ON RECTANGULAR CONVERGENT AND DIVERGENT RIBBED CHANNELS

Principles of Convection

EXPERIMENTAL STUDY OF HEAT TRANSFER AND PRESSURE LOSS IN CHANNELS WITH MINIATURE V RIB-DIMPLE HYBRID STRUCTURE

Comparative Analysis of Heat Transfer and Friction Characteristics in a Corrugated Tube

UNIT II CONVECTION HEAT TRANSFER

Convective Heat Transfer and Thermal Performance in a Circular Tube Heat Exchanger Inserted with U-Shaped Baffle

5th WSEAS Int. Conf. on Heat and Mass transfer (HMT'08), Acapulco, Mexico, January 25-27, 2008

Flow and Heat Transfer Profiles in a Square Channel with 45 V-Downstream Orifices

Performance Investigation of Artificially Roughened Duct used in Solar Air Heaters

Piping Systems and Flow Analysis (Chapter 3)

Heat Transfer Enhancement in Turbines using Dimples- A CFD Study Nitish Kumar Jain 1 Dr.U.S. Mallikarjun 2

Introduction to Heat and Mass Transfer. Week 12

COMPUTATIONAL FLUID DYNAMICS ON DIFFERENT PASSAGES OVER A PLATE COIL EVAPORATOR FOR 40 LITER STORAGE TYPE WATER COOLER

Numerical study of heat transfer enhancement by rectangular winglet vortex generator pair in a channel

HEAT TRANSFER. PHI Learning PfcO too1. Principles and Applications BINAY K. DUTTA. Delhi Kolkata. West Bengal Pollution Control Board

Heat Transfer Performance in Double-Pass Flat-Plate Heat Exchangers with External Recycle

International Journal of Engineering, Business and Enterprise Applications (IJEBEA)

COMPUTATIONAL FLUID DYNAMICS ANALYSIS ON HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF A TURBULENT FLOW FOR INTERNALLY GROOVED TUBES

Convection. forced convection when the flow is caused by external means, such as by a fan, a pump, or atmospheric winds.

Theoretical and Experimental Studies on Transient Heat Transfer for Forced Convection Flow of Helium Gas over a Horizontal Cylinder

HEAT TRANSFER AND FLOW CHARACTERISTICS OF OFFSET FIN AND FLAT TUBE HEAT EXCHANGERS UNDER LOW PRESSURE ENVIRONMENT

Experimental Analysis on Pin Fin Heat Exchanger Using Different Shapes of the Same Material

UNCORRECTED PROOF ARTICLE IN PRESS

Heat Transfer Enhancement Analysis of Flow over the Bumps on Divergent Channel

Experimental Investigation of Adiabatic Film Cooling Effectiveness and Heat Transfer Coefficients over a Gas Turbine Blade Leading Edge Configuration

R09. d water surface. Prove that the depth of pressure is equal to p +.

A study of Heat Transfer Enhancement on a Tilted Rectangular Stainless Steel Plate

Applied Fluid Mechanics

Applied Fluid Mechanics

Nusselt Number Correlation of SAH

Numerical Investigation on Air Side Performance of Fin and Tube Heat Exchnagers with Different Types of Fins

ME-662 CONVECTIVE HEAT AND MASS TRANSFER

Numerical Investigation on Turbulent Forced Convection in Heating Channel Inserted with Discrete V-Shaped Baffles

Second law optimization of a solar air heater having chamfered rib groove roughness on absorber plate

Study on Impingement of Air Jet from Orifice on Convex Surface for Unconfined Flow

Transcription:

IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X, Volume 13, Issue 5 Ver. III (Sep. - Oct. 2016), PP 70-76 www.iosrjournals.org Empirical study of heat transfer at input area of turbojet blades Mahdi Poormohamadi Raad, Alireza Roudbari MSC of Mechanical Engineering, KNToosi University Associate Professor of ShahidSattari University Abstract: The barriers against the flow or jags can be used, increasing of heat transfer rate. Turbojet blade cooling, heat convertors and solar air heater are the devices that jags used in them. Arrangement and geometry of jags are effective on heat and pressure transfer.in present study the heat transfer at turbojet turbine blades entrance has been studied empirically. The thin and square jags were compared distinctly.the air was imported to the conduit in to 3 Reynolds. Three step towards the jags height equal to 10, 20, 40, and 3jags height towards the hydraulic diameter of conduit equal to 0.068. 0.137 And 0.205 were considered and jags were implemented in 90 attack angle. In experimented domain, it was revealed that heat would be increased with reduction of step to jags height ratio and increasing of jags height to hydraulic diameter of conduit ratio. Keywords: Jag, heat transfer improvement, turbojet, constant heat flux, jag step, jag height. I. Introduction During the recent years, jags have the considerable applications such as turbine cooling, solar heaters and heat convertors. Turbojet engines mainly rely on generated power obtained from the output gases. In turbojet engines, the air enters to the compressor at first and compacted. However, this air is not suitable for combustion because of its high speed and the most of fuel wasted without combustion. Due to that, the air sent to diffuser or speed reducer to reduce its speed. In diffuser, at first, the air speed is reduced and then its temperature and pressure increases; after that this air transmitted to the combustion chamber. Figure one shows that there are some different ways for cooling the gas turbine blade such as spray, cooling with fluid film, using the jags and the form of cooling paths (Han et al, 1984). Fig1. Different ways of cooling the gas turbine blades (Han et al, 1984) In this article, cooling the gas turbine blades at entrance areawill be done, using some kind of turbulence maker called jags. Although, using the jags increase the heat transfer but it caused the pressure reduction. Therefore, it is necessary to study both heat transfer increasing and pressure reduction. The rate of heat transfer into the canal is low for the air, because the air has the low heat conductivity and capacity (Gao et al, 6). Low heat transfer depends on a sublayer under the transfer surface that should be broken for the heat transfer improving. Flow fluctuation is the one of those ways via the bed roughing (Aharwala et al, 8). Using the jags can be effective in heat transfer and coefficient increasing. Han et al. (1978) evaluated the jags form, attack angle and the step ratio to jags height on friction coefficient; in a rectangular canal with two rough walls,figure 2 describes them. DOI: 10.9790/1684-1305037076 www.iosrjournals.org 70 Page

Fig2. Important geometric parameter of jags (Han et al, 1978) Han et al.(1992) and Kiml et al.(1) reported that attack angle of jags with 60 has the better results than 45.Lau et al. (1991) evaluated the heat transfer and pressure reduction in the completely expanded area in a square canal with discrete transverse jags. They found that heat transfer coefficient in discrete state is 10 to 15% more than continuous state.cho et al, 0, experimented the effect of attack angle and the number of discrete jags. They understood that the gap between the jags accelerate the flow and increase the heat transfer.doherty et al, 1, studied the effect of jags in a canal by the numerical and experimental methods. They found that when the canal dimension equals to 0.37 and the ratio of step than jags equals to 10 is the optimum state. Liou et al, 1993, studied the numerical and empirical methods of heat transfer in a canal with asymmetric jag locations. Also Ryu et al, 7, evaluated the jag s form such as square, triangular and semicircular forms in heat transfer of turbulent flow in a wide range of Reynolds numbers. Billen et al, 9, assessed the characteristics of heat transfer and friction for the turbulent and expanded airflow in a canal with circular, rectangular and trapezoidal furrows, empirically. Conclusions show the importance of jags in heat transfer mechanisms and devices such as solar heaters. However, the necessity of more studies in this field is obvious for quantitative and qualitative improvements. For this aim, an educational set for studying the jags effect has been designed in this article. Empirical device manufacturing Evaluating the step and height of jag in heat transfer, an empirical device has been designed and made. Figure 3 shows the general view of device. Fig3. Schematic of Empirical Device A fan located at the beginning of device for the flow conduction into the canal. Its power is adjustable and the flux and Reynolds can be controlled. The orifice located then, the mass flux can be calculated by it. Figure 4 shows the fan. Fig4. A figure of used fan Figure 5 shows the orifice. A punched surface located against the flow direction; it causes the pressure loss. A liquid manometer used to measure this loss. DOI: 10.9790/1684-1305037076 www.iosrjournals.org 71 Page

Fig5. The Orifice Figure 6 shows that after the orifice a glass canal, 76*76 mm cross section with 1524 mm length, located to generate a completely expanded flow. Fig6. A view of glass canal Heating area located after the glass canal. This area is a steel canal with 76*76 mm cross section, 16 mm length and 3 mm thickness. Electrical heaters with plate form utilized for the heating process with specific resistance and providing the 0 W power. An important property of this heater is the continuous heat flux. Thermistors used, measuring the temperature at various points. Figure 7 shows the thermistors locating way into the canal. Fig7. Thermistors locating way into the canal Wooden jags with 5 mm thickness utilized, fluctuating the flow (figure 8). Fig8. A view of used jags in canal Ratio of P/e equals to 10, 20 and 40. e/d ratio equals to 0.068, 0.137 and 0.205. The jags located in 90 attack angle in two opposite surfaces. An auto-trans device or mono-phase voltage regulator, TDGC2-3 model, has been used for the generating and controlling the different heat fluxes on rough bed and without jag bed. Figure 9 shows the Auto-trans. DOI: 10.9790/1684-1305037076 www.iosrjournals.org 72 Page

Fig9. Auto-trans Governing Equations Reynolds number calculated as below: R )1( Where the u is the air velocity, ρ is the Density equals to 1.177, D h is the equivalent hydraulic diameter and µ is the dynamic viscosity equals to 1.864 10-5. The heat transfer coefficient obtained as below: )2( Where the q is the heat flux and q loss is the loss flux that considered 5 to 20 % of heat flux. The loss flux in this study considered 5 % because of suitable insulation. Tw and Tb are the temperature of wall and canal center respectively. sselt number () obtained as below: N )3( Where k is, the air heat conductivity equals to 0.0245. Average calculated as below: N )4( Relation 5 shows the friction coefficient equation. f )5( Where L is the length of part that pressure loss measured along it.the coefficient of thermal performance calculated as below: η )6( The and f compared with relations 7 (Kakac and Spalding, 1979) and eight (Han et al, 1984) for validation assessment. N )7( )8( The amount of 2Rav/D considered equal to 1.156 DOI: 10.9790/1684-1305037076 www.iosrjournals.org 73 Page

Empirical study of heat transfer at input area of turbojet blades II. Results In this part, for the comparison and validation, results of without jag surface measurements compared with obtained results of relations 7 and 8 for different Reynolds. As it can be seen in figures 10 and 11, there is suitable compatibility between the experiment results and the relations 7 and 8. 90 80 70 60 50 40 30 20 10 0 0 3 4 5 Re Petokhov-Popov correlation Fig10. in compare to Petokhov-Popov relation Effect of jags Step-height ratio Figures 11, in 12 and 13 show the heat transfer trend in the middle of jags, in jag height ratio to hydraulic diameter equal to 0.0685 and at 90 attack angle respectively for three step-height ratio of 10, 20 and 40 in Reynolds 130, 20 and 3. As it can be seen, at first in all steps, the heat transfer is high because of the high temperature gradient and lack of boundary layer; during the h increasing and boundary layer generation, the changes reduce rapidly and will be constant.the changes of is more in the beginning of canal in step-height ratio equal to 10. Decreasing the ratio, the length of entrance area declines because of the flow turbulence increasing. The number of jags, reaching the improved state in step-height ratios 10, 20 and 40 are five, three and two respectively. In addition, in step-height ratio equal to 10, along with Reynolds increasing, the overshoot amount reached from 58.3 % to 60% whereas for steps 20 and 40 it reached from 50.3 to 53% and 39.8 to 43.4 % respectively. 4 350 3 250 150 0 5 10 15 20 Fig11. changes in the middle of jags per canal length for P/e=10, e/d=0.068andθ =90 4 350 3 250 150 Re=13 0 Re=22 0 0 5 10 15 20 Re=130 Re=220 Fig12. changes in the middle of jags per canal length for P/e=20, e/d=0.068andθ =90 DOI: 10.9790/1684-1305037076 www.iosrjournals.org 74 Page

280 260 240 220 180 160 140 120 Empirical study of heat transfer at input area of turbojet blades 0 2 4 6 8 10 12 14 16 Fig13. changes in the middle of jags per canal length for P/e=40, e/d=0.068andθ =90 Effect of jags height to canal hydraulic diameter Figures 11, 14 and 15 show the heat transfer along the canal for step-height 10 for Reynolds 130, 20 and 3 for 3 different height-hydraulic diameter 0.0685, 0.137 and 0.205. 550 5 450 4 350 3 250 150 Re=130 Fig14. changes in the middle of jags per canal length for P/e=10, e/d=0.137andθ =90 240 220 180 160 140 120 0 5 10 15 20 Fig15. changes in the middle of jags per canal length for P/e=10, e/d=0.205andθ =90 In the lowest amount of height ratio, the changes are more than other heights. Increasing the ratio, the changes decreased because of more flow turbidity. Second reason maybe the more distance between the jags. In each ratio the Reynolds, changes did not have considerable effect on general trend of heat transfer. For the three height ratio of 0.0685, 0.137 and 0.205 the number of jags for the improvement are 5, 3 and 2 respectively. The length of entrance area was constant in response of height-hydraulic diameter ratio and fixing the step-height ratio from 0.685 to 0.137. It a bit decreased at 0.137 to 0.205 changing. In addition, the overshoot amount in Reynolds 20 obtained for each one of jags heights equal to 58%, 62% and 40%. Re=130 Re=220 0 2 4 6 8 10 12 14 16 Re=13 0 Re=22 0 DOI: 10.9790/1684-1305037076 www.iosrjournals.org 75 Page

III. Conclusion In this article, an experimental device was made for evaluating the heat transfer and pressure loss in heat exchange canals, with turbine blades cooling application in turbojets by the thin jags. At first, the obtained results for turbojet blades simulation evaluated for a canal without any jag. The results showed suitable accommodation. Study shows that canal roughing caused the reduction of entrance area length and overshooting because of the flow more turbidity. Reducing the step-height ratio, the jag number along the flow path will increase and heat transfer increases consequently. Increasing the jags step, the distance between the flow return and separation point will increase that causes the boundary layer expansion and decreasing the average heat transfer consequently. The entrance length decreases via the step-height ratio decreasing but there is not considerable change for entrance area via the height-hydraulic diameter changes. References [1]. j. c. Han, J. S. Park and C. K. Lei, November 1984. Heat Transfer and Pressure Drop in Blade Cooling Channels With Turbulence Promoters, NASA. [2]. Gao A., Wenxian Lin A. B., Tao Liu a., Chaofeng Xia., 6. Analytical and experimental studies on the thermal performance of cross-corrugated and flat-plate solar air heaters, Applied Energy, Vol. 84, pp. 425 441. [3]. K. R. Aharwala., B. K. Gandhib., J. S. Sainib., 8. Experimental investigation on heat-transfer enhancement due to a gap in an inclined continuous rib arrangement in a rectangular duct of solar air heater, Renewable Energy, Vol. 33, pp. 585 596. [4]. Han J. C., Glicksman L. R., Rosenow W. M., 1978. Investigation of heat transfer and friction for rib-roughened surfaces. Int J Heat Mass Transfer, Vol. 21, pp. 1143 56. [5]. J. C. Han., J. S. Park., C. K. Lei., 1985. Heat Transfer Enhancement in Channels with Turbulence Promoters, ASME J. Eng. Gas Turb, Vol. 107, pp. 628 635. [6]. Han J. C., Park J. S., 1988. Developing heat transfer in rectangular channels with rib turbulators. Int J Heat Mass Transfer, Vol. 3, pp. 183 95. [7]. Han J. C., Zhang Y. M., 1992. High performance heat transfers ducts with parallel broken and V- shaped broken ribs. Int J Heat Mass Transfer, Vol. 35, pp. 513 23. [8]. Kiml R, Mochizuki S, Murata A, 1. Effects of rib arrangements on heat transfer and flow behavior in a rectangular rib roughened passage. J Heat Transfer, Vol. 123, pp. 675 81. [9]. Lau S. C., McMillin R. D., Han J. C., 1991. Turbulent heat transfer and friction in a square channel with discrete rib turbulators. Trans ASME, J Turbo Machinery, Vol. 113, pp. 360 6. [10]. Lau S. C., McMillin R. D., Han J. C., 1991. Heat transfer characteristics of turbulent flow in a square channel with angled rib. Trans ASME, J Turbomachinery, Vol. 113, pp. 367 74. [11]. Cho H. H., Wu S. J., Kwon H. J., 0. Local heat/mass transfer measurement in a rectangular duct with discrete ribs. J Turbomachinery, Vol. 122, pp. 579 86. [12]. O Doherty T., Jolly A. J., Bates C. J., 1. Optimisation of heat transfer enhancement devices in a bayonet tube heat exchanger. Appl Therm Eng, Vol. 21, pp. 19 36. [13]. Liou T. M., Hwang J. J., Chen S. H., 1993. Simulation and measurement of enhanced turbulent heat transfer in a channel with periodic ribs on one principal wall. Int J Heat Mass Transfer, Vol. 36, pp. 507 17. [14]. Ryu D. N., Choi D. H., Patel V. C., 7. Analysis of turbulent flow in channels roughened by two-dimensional ribs and threedimensional blocks. Part I: Resistance. Int J Heat Fluid Fl, Vol. 28, pp. 1098 111. [15]. Ryu D. N., Choi D. H., Patel V. C., 7. Analysis of turbulent flow in channels roughened by two-dimensional ribs and threedimensional blocks. Part II: Heat transfer. Int J Heat Fluid Fl, Vol.28, pp. 1112 24. [16]. Bilen K., Cetin M., Gul H., Balta T., 9. The investigation of groove geometry effect on heat transfer for internally grooved tubes, Appl. Therm. Eng, Vol. 29, pp. 753-761. [17]. P. W. Dittus and L. M. K. Boelter., 1985. Heat transfer in automobile radiators of the turbular type, Univ. Calif. Publ. Eng., Vol.2, No. 13, Oct. 17, 1930, pp 443-461; reprinted in Int. Cmmun. Heat Mass Transfer, Vol. 12, pp. 3-22. [18]. S. Kakac, and D. Spalding, 1979. Turbulent Forced Convection in Channels and Bundles, New York: Hemisphere Publishing Corp. DOI: 10.9790/1684-1305037076 www.iosrjournals.org 76 Page