Application of Virtual Synchronous Generator in Solar Power Generation

Similar documents
Single-Phase Synchronverter for DC Microgrid Interface with AC Grid

SCHOOL OF ELECTRICAL, MECHANICAL AND MECHATRONIC SYSTEMS. Transient Stability LECTURE NOTES SPRING SEMESTER, 2008

Research of Hybrid Three-phase equilibrium Technology

ENHANCEMENT MAXIMUM POWER POINT TRACKING OF PV SYSTEMS USING DIFFERENT ALGORITHMS

Virtual Inertia: Current Trends and Future Directions

MICROGRID is a future trend of integrating renewable

Chapter 3 AUTOMATIC VOLTAGE CONTROL

Research on State-of-Charge (SOC) estimation using current integration based on temperature compensation

ECE 325 Electric Energy System Components 7- Synchronous Machines. Instructor: Kai Sun Fall 2015

Research on Permanent Magnet Linear Synchronous Motor Control System Simulation *

Unified Power Flow Controller (UPFC) Based Damping Controllers for Damping Low Frequency Oscillations in a Power System

Coupled vibration study of the blade of the flexible wind wheel with the low-speed shafting

From now, we ignore the superbar - with variables in per unit. ψ ψ. l ad ad ad ψ. ψ ψ ψ

Mathematical Modeling and Dynamic Simulation of a Class of Drive Systems with Permanent Magnet Synchronous Motors

Centralized Supplementary Controller to Stabilize an Islanded AC Microgrid

PV-based virtual synchronous generator with variable inertia to enhance power system transient stability utilizing the energy storage system

Performance Evaluation of DFIG to Changes in Network Frequency

SYNCHRONOUS GENERATOR s ROTOR INVESTIGATION OF A HYBRID POWER SYSTEM INCLUDING A.G.

LESSON 20 ALTERNATOR OPERATION OF SYNCHRONOUS MACHINES

University of Jordan Faculty of Engineering & Technology Electric Power Engineering Department

Robust Control For Variable-Speed Two-Bladed Horizontal-Axis Wind Turbines Via ChatteringControl

A Computer Application for Power System Control Studies

Modeling Free Acceleration of a Salient Synchronous Machine Using Two-Axis Theory

FOR REDUCE SUB-SYNCHRONOUS RESONANCE TORQUE BY USING TCSC

Power system modelling under the phasor approximation

An Novel Continuation Power Flow Method Based on Line Voltage Stability Index

Analysis of Coupling Dynamics for Power Systems with Iterative Discrete Decision Making Architectures

Model of a DC Generator Driving a DC Motor (which propels a car)

1439. Numerical simulation of the magnetic field and electromagnetic vibration analysis of the AC permanent-magnet synchronous motor

Dynamic Modeling of Surface Mounted Permanent Synchronous Motor for Servo motor application

EE 451 Power System Stability

A Power System Dynamic Simulation Program Using MATLAB/ Simulink

Torques 1.0 Two torques We have written the swing equation where speed is in rad/sec as:

Transient Stability Assessment of Synchronous Generator in Power System with High-Penetration Photovoltaics (Part 2)

Effects of the Controller Performance of DFIG on its Inertia Response

You know for EE 303 that electrical speed for a generator equals the mechanical speed times the number of poles, per eq. (1).

Lesson 17: Synchronous Machines

Predicting, controlling and damping inter-area mode oscillations in Power Systems including Wind Parks

Reaction Wheel Control Design Using Linear Quadratic Controller

A Review and Modeling of Different Droop Control Based Methods for Battery State of the Charge Balancing in DC Microgrids

1 Unified Power Flow Controller (UPFC)

REAL TIME CONTROL OF DOUBLY FED INDUCTION GENERATOR. Benmeziane Meriem, Zebirate Soraya, Chaker Abelkader Laboratory SCAMRE, ENPO, Oran, Algeria

World Academy of Science, Engineering and Technology International Journal of Computer and Systems Engineering Vol:7, No:12, 2013

The synchronous machine (SM) in the power system (2) (Where does the electricity come from)?

Transient Stability Analysis of Single Machine Infinite Bus System by Numerical Methods

Power System Stability GENERATOR CONTROL AND PROTECTION

Research on the Laser Doppler Torque Sensor

Transient Stability Improvement of a Multi- Machine Power System by Using Superconducting Fault Current Limiters

Control of Wind Turbine Generators. James Cale Guest Lecturer EE 566, Fall Semester 2014 Colorado State University

Open Access Permanent Magnet Synchronous Motor Vector Control Based on Weighted Integral Gain of Sliding Mode Variable Structure

Power Grid Partitioning: Static and Dynamic Approaches

Enhanced Virtual Synchronous Generator Control for Parallel Inverters in Microgrids

An Introduction to Electrical Machines. P. Di Barba, University of Pavia, Italy

Mathematical Modeling and Dynamic Simulation of DC Motors using MATLAB/Simulink Environment

QUESTION BANK ENGINEERS ACADEMY. Power Systems Power System Stability 1

Generators. What its all about

Q-V droop control using fuzzy logic and reciprocal characteristic

SoC Balancing of Different Energy Storage Systems in DC Microgrids Using Modified Droop Control

Participation in the Frequency Regulation Control of a Resilient Microgrid for a Distribution Network

Comparative Study of Synchronous Machine, Model 1.0 and Model 1.1 in Transient Stability Studies with and without PSS

CHAPTER 3 MATHEMATICAL MODELING OF HYDEL AND STEAM POWER SYSTEMS CONSIDERING GT DYNAMICS

Transient Stability Analysis with PowerWorld Simulator

A Novel Adaptive Estimation of Stator and Rotor Resistance for Induction Motor Drives

Fuzzy modeling and control of rotary inverted pendulum system using LQR technique

Self-Tuning Control for Synchronous Machine Stabilization

Comparative Analysis of an integration of a Wind Energy Conversion System of PMSG and DFIG Models Connected to Power Grid

arxiv: v1 [cs.sy] 24 Mar 2016

Synergetic Control for Electromechanical Systems

In these notes, we will address (2) and then return to (1) in the next class.

Massachusetts Institute of Technology Department of Electrical Engineering and Computer Science Electric Machines

Synchronous Machines

Chapter 9: Transient Stability

International Journal of Advance Engineering and Research Development SIMULATION OF FIELD ORIENTED CONTROL OF PERMANENT MAGNET SYNCHRONOUS MOTOR

Inductance and Current Distribution Analysis of a Prototype HTS Cable

CHAPTER 2 MATHEMATICAL MODELLING OF AN ISOLATED HYBRID POWER SYSTEM FOR LFC AND BPC

A Novel Three-phase Matrix Converter Based Induction Motor Drive Using Power Factor Control

A simple model based control of self excited induction generators over a wide speed range

SPEED-GRADIENT-BASED CONTROL OF POWER NETWORK: CASE STUDY

Power System Stability and Control. Dr. B. Kalyan Kumar, Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai, India

Robust Tuning of Power System Stabilizers Using Coefficient Diagram Method

DAMPING OF SUBSYNCHRONOUS MODES OF OSCILLATIONS

Journal of Physics: Conference Series. Related content PAPER OPEN ACCESS

PARAMETER SENSITIVITY ANALYSIS OF AN INDUCTION MOTOR

International Conference on Advances in Energy and Environmental Science (ICAEES 2015)

CHAPTER 2 DYNAMIC STABILITY MODEL OF THE POWER SYSTEM

Fuzzy optimum opertaing of a wind power pumping system

Grid-connected photovoltaic systems based on nonlinear control.

DYNAMIC RESPONSE OF A GROUP OF SYNCHRONOUS GENERATORS FOLLOWING DISTURBANCES IN DISTRIBUTION GRID

Motion Control of the Pressing Rollers in the Paper Tape Crimping Machine Based on Servo Control

Generation, transmission and distribution, as well as power supplied to industrial and commercial customers uses a 3 phase system.

Introduction to Synchronous. Machines. Kevin Gaughan

Research Article Sliding Mode Control for the Synchronous Generator

Optimal Placement and Sizing of Grid-Forming Inverters

Chapter 8: Converter Transfer Functions

Natural frequency analysis of fluid-conveying pipes in the ADINA system

c 2014 Olaoluwapo Ajala

Design of PSS and SVC Controller Using PSO Algorithm to Enhancing Power System Stability

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II : 7 - Transient Stability

ECEN 420 LINEAR CONTROL SYSTEMS. Lecture 6 Mathematical Representation of Physical Systems II 1/67

PV Characteristics and Their Maximum Power Point Tracking Algorithms using LabVIEW

Transcription:

Journal of Physics: Conference Series PAPER OPEN ACCESS Application of Virtual Synchronous Generator in Solar Power Generation To cite this article: Jianjun Su et al 18 J. Phys.: Conf. Ser. 187 66 View the article online for updates and enhancements. This content was downloaded from IP address 148.51.3.83 on 4/1/19 at 17:45

IOP Conf. Series: Journal of Physics: Conf. Series 13456789 187 (18) 66 doi :1.188/174-6596/187/6/66 Application of Virtual Synchronous Generator in Solar Power Generation Jianjun Su 1, Wenbo Li 1, Hengjie Liu, Fanmin Meng, Long Wang 3, Xueshan Han 3 1 State Grid Shandong Electric Power Research Institute, China. State Grid Laiwu Power Supply Company, China. 3 Key Laboratory of Power System Intelligent Dispatch and Control of Ministry of Education (Shandong University), Jinan, China. wanglong_9@163.com Abstract. For the virtual synchronous control strategy of grid-connected inverters, the impact of the output response of the change of source is mainly analyzed, and the response time is calculated to lay a theoretical foundation for the system economic dispatch. First, the photovoltaic cell model is introduced, as well as the mathematical model and control strategy of the virtual synchronous generator. Then the optimal configuration of the source input is analyzed under different inertia and virtual damping conditions. The results show that the virtual inertia and damping coefficient of the inverter are closely related to the energy density and response time of the source input. Finally, a simple simulation model is given to observe the influence of the output change of the source on the response of the inverter output. 1. Introduction With the large-scale consumption of new energy such as wind energy and photovoltaics, the system is facing a series of new challenges. The virtual synchronization technology is a major technological innovation and has been received significant attention at home and abroad recently. An adaptive inertial control strategy is proposed that selects different rotor inertias based on the acceleration and slip of the virtual synchronous machine and verifies the state of its negative inertia[1]. A strategy adjusting the voltage and reactive power by adding excitation links is introduced[]. In the literature[3], on the basis of the predecessors, the synchronverter scheme is proposed. The equivalent structural is analyzed and mathematical equations of the inverter and the synchronous generator are compared and analyzed. The control strategy inherited and developed and summarized the correlation of the virtual synchronous machine theory. In Literature[4], by detecting the frequency change rate in the transient process, the functional relationship of the frequency drop coefficient of the VSG droop is established, and the droop coefficient is adjusted according to the change of the frequency to reduce the frequency deviation in the transient process. Literature [5] studies the relationship between the magnitude and frequency of virtual inertia and gives a quantitative selection method of virtual inertia. Based on the small-signal model, the design principles of relevant parameters are proposed, and the adaptive control of virtual inertia is studied. This article will be based on the above introduction, first we gives the photovoltaic cell model, introduces the basic principle of the virtual synchronous generator; then we gives the second-order model of the virtual synchronous machine, and analyzes its response time; Finally, we gives the simulation results, changes Irradiation and other sources of input to verify the system output response time. Content from this work may be used under the terms of the Creative Commons Attribution 3. licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by Ltd 1

IOP Conf. Series: Journal of Physics: Conf. Series 13456789 187 (18) 66 doi :1.188/174-6596/187/6/66. Photovoltaic model The output current of the photovoltaic cell according to the KCL law is: I I I I p h d r s I ( ) ph I sc + K T Tref 1 Isc( T ) Isc( T1) K T T 1 q ( u + ir )/ akt I ( 1) d I e qeg T 3 ak (1/ Tref 1/ T ) do Tref I I ( ) e I ( U+ IR)/ R r Formula (1)~(6) is the mathematical model of single diode photovoltaic cell. Where, Isc for the shortcircuit current, A; Ido for the diode reverse current, A; S for the irradiation intensity, W / m ;T for the battery surface temperature, K ; α for the diode quality factor; q for the electronic power, 1.6 1 19 3, C ; 1.38 1 for the Boltzmann constant, J / K,; E g With energy constants, ev. Photovoltaic cells form a photovoltaic array through series and parallel connection. The relationship between output voltage and current is as follows: q U IR s N p U IRs I NpIph NpIsexp ( + ) 1 ( + ) akt Ns N p Rsh Ns N p Where, Ns represents the number of batteries in series and N p represents the number of parallel batteries. 3. VSG model Taking the VSG's terminal connection point as the common coupling point, the renewable energy can be equivalent to the traditional prime mover, the energy storage unit can be equivalent to the traditional steam engine, and the grid-connected inverter can be equivalent to the traditional synchronous generator. Traditional synchronous generators include second-order, third-order, fifth-order, and seventh-order mathematical models. Here, only the simplest second-order electromechanical model analysis is considered. The key to the second-order model is the rotor motion equation and the electromagnetic equation. 3.1. Electromagnetic equation The electromagnetic equation of a virtual synchronous generator is diabc L eabc uabc Riabc dt Where, Lrepresents the synchronous inductance of the synchronous generator, H ; R represents the synchronous resistance of the synchronous generator, Ω ; e abc represents the internal potential, V ; uabc represents the terminal voltage of the synchronous generator, V. The virtual synchronous generator's virtual potential consists of three parts. E is the no-load voltage of the virtual synchronous generator; the second is the reactive power regulation part E q, expressed as sh

IOP Conf. Series: Journal of Physics: Conf. Series 13456789 187 (18) 66 doi :1.188/174-6596/187/6/66 Δ E q k q ( Q ref Q ) Where, k q represents the reactive power adjustment coefficient; Q ref is the reactive power instruction of the grid-connected inverter; Q is the instantaneous reactive power value output by the machine. Δ E u is the output voltage of the terminal voltage regulator unit, which is equivalent to the excitation regulator or automatic voltage regulator of the synchronous generator, which can be simplified as a proportional element. Δ E u k u ( U ref U ), Where, k u indicates the voltage adjustment coefficient; U ref and U are the command value and the real value that represent the effective value of the terminal voltage. The analogy of the inverter filter to the virtual impedance of the synchronous generator has some problems. The parameter design of the filter needs to consider factors such as reactive power, voltage drop and the like, and at the same time, parameter drift occurs, which is related to the parameter design in the control model. There is some error. 3.. Mechanical equation The mechanical equation of the virtual synchronous generator is dω J Tm Te Td Tm D( ω ω ) dt Where, J represents the moment of inertia, kg m ; the mechanical angular velocity of the synchronous generator ω is equal to the electrical angular velocity; ω is the synchronous angular velocity of the power grid, rad / s ; T m/ T e / T d are the mechanical torque, electromagnetic torque, and damping torque of the synchronous generator, respectively; D is the damping coefficient, Nms / rad. The electromagnetic torque of a virtual synchronous generator Te can be calculated from the virtual synchronous generator voltage and current T P/ ω ( ei + ei + ei)/ ω e e a a b b c c Where, e indicates the air gap electromotive force, V ; i represents the output current, A ; represents the output electromagnetic power of the virtual synchronous generator. 3.3. Inertia and damping The moment of inertia of a synchronous generator is a physical quantity, and inertial time constant H is generally used to measure the inertia of synchronous generators of different sizes and power levels. H is defined as H Jω / S n Where, Sn represents the rated capacity of the synchronous generator: H represents the time that the synchronous generator is at nominal torque from no-load start to the rated speed. Based on the concept of the inertial time constant, the second-order model of the synchronous generator is obtained from the above equation: δ ωω r * * * * H ωr Tm Te Dpωr Pref Pe Dpωr Pe 3

IOP Conf. Series: Journal of Physics: Conf. Series 13456789 187 (18) 66 doi :1.188/174-6596/187/6/66 ω ( ω ω)/ ω indicates the speed difference; the system asterisk indicates the standard system, r the torque reference value is Tb Sn/ ω. In addition, D / p Dω Sn, the relationship between * * * power and speed is P T ω. In general, due to the physical conditions of the synchronous generator, the inertial time constant of different generator sets different in several seconds. The inertial time constant of the virtual synchronous generator is a function related to the virtual inertia. It has the characteristics of flexible and variable, and it has the advantages of the adjustment range that the traditional synchronous machine does not have. It can realize the adjustment of different time scales. The problem is that the choice of inertial time constant and the dynamic response time of the virtual synchronous generator DC power supply should match. For example, the inertia time constant of the wind turbine is second level, and the dynamic time constant of the photovoltaic cell is millisecond level. The dynamic constant of the energy storage battery varies due to different properties. According to the single-machine infinite-bus system, the output of active power and reactive power of a virtual synchronous generator can be expressed as: EU U Pe cos( α δ) cosα Z Z EU U Qe sin( α δ) sinα Z Z Where, the impedance Z of the filter inductor and the impedance angle α are: Z ( ωl) + R 1 ωl α tan ( ) R According to the second-order virtual synchronous generator model obtained by analogy, the smallsignal analysis model of the virtual synchronous generator can be obtained by referring to the smallsignal model analysis method of the conventional synchronous generator. From the foregoing, we can see that the second-order electromechanical model adopted in this paper can be used to derive the second-order transfer function of the input and output power response characteristics of a virtual synchronous generator: * Pe ωse / H Gs () * Pm s + ( Dp / H) s+ ωse / H Where, S E is the standard value of the synchronous power, * Pe EU s SE sin( α δ) δ SZ n Where, Es and δare the stable operation equilibrium points related to the active power and reactive power obtained by the power equation derivation. Since the filter inductance parameters are known and the grid voltage U is constant, the solution can be solved Q sin / 1 ref + U α Z δs α tan ( ) Pref + U sin α / Z Qref Z + U sinα Es U sin( α δs ) It can be seen that in the case of a given active power command, S E is a constant, which the natural oscillation angle frequency and damping coefficient of the second-order model can be derived. 4

IOP Conf. Series: Journal of Physics: Conf. Series 13456789 187 (18) 66 doi :1.188/174-6596/187/6/66 ωn ωse / H ξ.5d 1/ ( ωseh) 4. Simulation In MATLAB/Simulink, a simulation model for photovoltaic cells directly connected to the VSG is built. The simulation parameters are shown in the table. The simulation process is as follows:.3s simulated cloud shelter, lighting is reduced from 1 W / m to 35 W / m, temperature is maintained at 4 C; 1.4s is simulated in the evening, light and temperature are simultaneously decreased, light is reduced from 1 W / m to 8W / m, temperature is decreased from 4 C to 35 C, 1.8s light fell to W / m, the temperature dropped to 3 C. 5

IOP Conf. Series: Journal of Physics: Conf. Series 13456789 187 (18) 66 doi :1.188/174-6596/187/6/66 It is not difficult to find from the figure that the input light and temperature changes, the uncertainty of photovoltaic output is simulated, and the dynamic tracking response at the output end of the photovoltaic cell exhibits certain volatility, and the voltage tracking effect is slightly different. The power tracking effect basically conforms to the light curve. Simulation results show that the tracking time is around.1. Observed from the VSG output terminal, taking the DC input as a reference, its power tracking effect is good, and the response time is about.1s. 5. Conclusion From an engineering point of view, the current photovoltaic application scenario is basically a direct grid-connected storage without energy storage. In the foreseeable future, because the cost of energy storage batteries is high, photovoltaic batteries directly connected to the virtual synchronous control inverter are the most possible options. It is necessary to study the inverter tracking effect of photovoltaic directly connected to the virtual control. From the perspective of the dynamic time, the time range of the scheduling given by the uncertainty output at the source is analyzed, and the time reference value of the dynamic scheduling is given. In the next step, we will continue to use the second-order model to analyze the changes in the input of the step at the source, the voltage response range and the power response range of the system, and then provide the constraint range of the real-time scheduling of the inverter. References [1] Alipoor, J., Y. Miura and T. Ise, 15, Power System Stabilization Using Virtual Synchronous Generator With Alternating Moment of Inertia, IEEE Journal of Emerging and Selected Topics in Power Electronics. 3(): 451-458. [] Chen, Y., et al., 1, Comparison of methods for implementing virtual synchronous machine on inverters. Renewable Energy and Power Quality Journal, 734-739. [3] Zhong, Q. and G. Weiss, 11, Synchronverters: Inverters That Mimic Synchronous Generators. IEEE Transactions on Industrial Electronics. 58(4): 159-167. [4] Soni, N., S. Doolla and M.C. Chandorkar, 13, Improvement of Transient Response in Microgrids Using Virtual Inertia. IEEE Transactions on Power Delivery. 8(3): 183-1838. [5] Cheng Chong,Yang Huan,Zeng Zheng,et al, 15, Rotor inertia adaptive control method of VSG, Automation of Electric Power Systems. 39(19):8-89(in Chinese) 6