Detector. Matthew Strugari, Dr. Garth Huber 1, Wenliang Li. University of Regina, Regina, SK, S4S 0A2, Canada. August 15, 2016.

Similar documents
SIDIS Gas CherenkovS. S. Malace, H. Gao et al.

The HERMES Dual-Radiator Ring Imaging Cerenkov Detector N.Akopov et al., Nucl. Instrum. Meth. A479 (2002) 511

An Overview of RICH Detectors From PID to Velocity Spectrometers

7 Particle Identification. Detectors for Particle Physics Manfred Krammer Institute of High Energy Physics, Vienna, Austria

Which of the following can be used to calculate the resistive force acting on the brick? D (Total for Question = 1 mark)

Lecture 16 Light transmission and optical detectors

The HARP Experiment. G. Vidal-Sitjes (INFN-Ferrara) on behalf of the HARP Collaboration

SHMS Aerogel Detector & Calorimeter Status. A. Mkrtchyan

Aerogel counter with a Fresnel lens. Guy Paic Instituto de Ciencias Nucleares UNAM Mexico

Physics sources of noise in ring imaging Cherenkov detectors

Particle Identification with Disc DIRC at PANDA

Interaction of particles with matter - 2. Silvia Masciocchi, GSI and University of Heidelberg SS2017, Heidelberg May 3, 2017

Status of the LHCb RICH detector and the HPD

σx=2.5cm, slpx =33mrd

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

Cherenkov Detector Simulation

SoLID Heavy Gas Cherenkov Update

Status of the LHCb RICH and hadron particle identification

THE CERN NA62 experiment [1] aims to measure the

Results from HARP. Malcolm Ellis On behalf of the HARP collaboration DPF Meeting Riverside, August 2004

EP228 Particle Physics

RICH detectors for LHCb

Picosecond Time-of-Flight Measurement for Colliders Using Cherenkov Light

The Factors That Limit Time Resolution for Photon Detection in Large Cherenkov Detectors

Hall C Inclusive Commissioning Experiments. Simona Malace Jefferson Lab

Particle Identification of the LHCb detector

Max. Central Momentum 11 GeV/c 9 GeV/c Min. Scattering Angle 5.5 deg 10 deg Momentum Resolution.15% -.2% Solid Angle 2.1 msr 4.

Cherenkov Detector. Cosmic Rays Cherenkov Detector. Lodovico Lappetito. CherenkovDetector_ENG - 28/04/2016 Pag. 1

Counting Photons to Calibrate a Photometer for Stellar Intensity Interferometry

Big, Fast, and Cheap: Precision Timing in the Next Generation of Cherenkov Detectors LAPPD Collaboration Meeting 2010

9/27 JUNE 2003 SUMMER STAGE PARTICLES REVELATION THROUGH CERENKOV AND SCINTILLATION COUNTER AND THE CEBAF EXPERIMENT

Guest Lecture PHY 7361: Harnessing Cherenkov Radiation SteveSekula, 13 April 2010 (created 9 April 2010)

Particle Energy Loss in Matter

Tests of the Burle anode MCP PMT as a detector of Cherenkov photons

Module of Silicon Photomultipliers as a single photon detector of Cherenkov photons

π + Electroproduction at High t

Particle Detectors A brief introduction with emphasis on high energy physics applications

Determination of parameters of cascade showers in the water calorimeter using 3D-distribution of Cherenkov light

PHYSICS 252 EXPERIMENT NO. 11 THE DYNAMICS OF ELEMENTARY PARTICLES

-221. FEATURES OF EXPERIMENTS AT ENERGIES ABOVE 1 TeV

The H.E.S.S. Standard Analysis Technique

CLAS12 at Jefferson Lab

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

Simulation of J/ψ detection via electron-positron decay

The reaction p(e,e'p)π 0 to calibrate the Forward and the Large Angle Electromagnetic Shower Calorimeters

E , E , E

Results from R&D of Cherenkov detectors at Novosibirsk

Kaon Identification at NA62. Institute of Physics Particle, Astroparticle, and Nuclear Physics groups Conference 2015

Large Acceptance High Luminosity Detector at 12 GeV

Lecture 4 Calorimetry. Lecture 5a - Particle Identification. Lecture 5b - Detector Systems/ Design

A RICH Photon Detector Module with G-APDs

Charged Particle Identification in GLUEX

PMT Charge Response and Reconstruction of Position and Energy for a Reactor θ 13 Experiment

Coherent photo-production of ρ 0 mesons in ultra-peripheral Pb-Pb collisions at the LHC measured by ALICE

The Aerogel Forward RICH detector for PANDA

1 Introduction. KOPIO charged-particle vetos. K - RARE Meeting (Frascati) May Purpose of CPV: veto Kl

Quartz TIR Cerenkov Detectors in Hall C

L/T Separated Kaon Production Cross Sections from 5-11 GeV

NA62: Ultra-Rare Kaon Decays

A pattern recognition method for the RICH-based HMPID detector in ALICE

Astronomy 114. Lecture 26: Telescopes. Martin D. Weinberg. UMass/Astronomy Department

The DIRC-like FTOF: A Time-of-Flight Cherenkov Detector for Particle Identification at SuperB

COMMISSIONING AND FIRST RESULTS OF THE NA62 RICH

Usage of GEANT 4 versions: 6, 7 & 8 in BABAR

Variation in MC prediction of MB nu flux

III. Energy Deposition in the Detector and Spectrum Formation

Validation of Geant4 Physics Models Using Collision Data from the LHC

HARP a hadron production experiment. Emilio Radicioni, INFN for the HARP collaboration

Particle Detectors Tools of High Energy and Nuclear Physics Detection of Individual Elementary Particles

2.24 Simulation Study of K L Beam: K L Rates and Background Ilya Larin Department of Physics Old Dominion University Norfolk, VA 23529, U.S.A.

PoS(KAON09)023. Beam Hole Photon Veto For J-PARC K O TO experiment. Yosuke Maeda Kyoto University

A New Look at the Galactic Diffuse GeV Excess

Polarized muon decay asymmetry measurement: status and challenges

XMASS 1.5, the next step of the XMASS experiment

Author s Accepted Manuscript

Particle Detectors. Summer Student Lectures 2010 Werner Riegler, CERN, History of Instrumentation History of Particle Physics

Development of Ring-Imaging Cherenkov Counter for Heavy Ions

Particle production vs. energy: how do simulation results match experimental measurements?

Simulation study of scintillatorbased

Tertiary particle production and target optimization of the H2 beam line in

Astronomy 114. Lecture 27: The Galaxy. Martin D. Weinberg. UMass/Astronomy Department

Monte Carlo Studies for a Future Instrument. Stephen Fegan Vladimir Vassiliev UCLA

Progress report on simulation and reconstruction developments & Progress report on observation strategies and estimation techniques (PART A)

HARP (Hadron Production) Experiment at CERN

Scientific / Technical Note

PoS(HIGH-pTLHC)022. The VHMPID detector in the ALICE experiment at LHC. Giacomo Volpe. INFN Bari, Italy

Optimization of Lead In The MOLLER Experiment

Particle Energy Loss in Matter

Ring recognition and electron identification in the RICH detector of the CBM experiment at FAIR

Modified energy-momentum conservation laws and vacuum Cherenkov radiation

WbLS measurements at BNL

Shower development and Cherenkov light propagation

PoS(ICHEP2016)293. The LArIAT experiment and the charged pion total interaction cross section results on liquid argon. Animesh Chatterjee

Cherenkov Detectors in Particle Physics. Brad Wogsland University of Tennessee

PoS(TIPP2014)093. Performance study of the TOP counter with the 2 GeV/c positron beam at LEPS. K. Matsuoka, For the Belle II PID group

Analyzing Data. PHY310: Lecture 16. Road Map

Particle Identification: Computer reconstruction of a UA1 event with an identified electron as a candidate for a W >eν event

New Hadroproduction results from the HARP/PS214 experiment at CERN PS

The NA62 RICH detector

Concepts of Event Reconstruction

Transcription:

1 Simulations for e/π Separation for the SHMS Heavy Gas Cherenkov Detector Matthew Strugari, Dr. Garth Huber 1, Wenliang Li University of Regina, Regina, SK, S4S 0A2, Canada August 15, 2016 Abstract The purpose of this report is to present the SHMS Heavy Gas Cherenkov (HGC) detector Geant4 simulation results pertaining to e/π separation between 1.3GeV/c p 7.2 GeV/c using C 4 F 10 and CO 2. This report assumes that the π/e production ratio at the simulated momenta of p = {1.5GeV/c, 3.0GeV/c, 5.0GeV/c, 7.0GeV/c} is π/e = {230, 20, 0.36, 0.0039} respectively. Based on our study, we recommend using CO 2 at P = 0.50atm. Fig. 1 presents the Cherenkov threshold pressure (P ) vs. the SHMS central momentum (p) for C 4 F 10 and CO 2. The black curve is the recommended operating pressure of the HGC detector for good e/π separation. This operating pressure was determined based on an assumed SHMS momentum acceptance of δ = ± 15% in addition to an assumed 10% HGC pressure mis-set. The HGC detector only allows sub-atmospheric pressure operation in its original conguration; thus under no circumstance shall the detector pressure exceed 1atm! The detector pressure must be adjusted depending on the pion momentum in order to obtain e/π separation. The threshold pressure plots were calculated based on the particle rest mass as well as the refractive index of the gas contained in the HGC. The formulae obtained for the refractive index 1 huberg@uregina.ca

Figure 1: Gas Pressure vs. Particle Momentum. The black curve represents the suggested gas pressure of the HGC detector for good e/π separation. The coloured curves represent the Cherenkov threshold pressure for different particles. 2

3 were for a fixed temperature and pressure of T = 0 o C and P = 1atm respectively. At a wavelength of 400nm, the index of refraction for C 4 F 10 is n 1atm = 1.001424 whereas the index of refraction for CO 2 is n 1atm = 1.000459. The wavelength dependent formulae were also implemented in Geant4 to properly simulate the gas contained within the HGC. The original detector simulation platform for Geant4 was developed at the University of Virginia. Numerous parameters have been implemented to accurately model the components of the HGC. This includes the vessel structure, mirror alignment and radii of curvature, PMT photocathode dimensions and efficiency characteristics, and the optics arrangements. Also, materialistic properties were used to accurately model the HGC components such as the atomic composition, reflectivity, photon absorption length, and refractive index. Additional functions related to Cherenkov radiation were implemented in Geant4 such as the production and tracking of secondary particles. It is essential to model secondary particles since sub-threshold particles can produce a signal due to knock-on electrons. Geant4 was configured to run multiple simulations over a range of pressure and momenta which produced a realistic estimate of the performance of the HGC for e/π separation. The simulated momenta included p = {1.5GeV/c, 3.0GeV/c, 5.0GeV/c, 7.0GeV/c} and the pressures ranged from 0.25atm P 0.95atm for C 4 F 10 and 0.25atm P 0.75atm for CO 2. The simulations employed a particle sample size of 200000 which were run separately for the electron and pion. Results were later modified using π/e ratios extrapolated from plots presented in E12-10-002 and E12-10-008/E12-06-105 Commissioning Experiments by Simona Malace. The extrapolated π/e ratios for carbon at the aforementioned momenta are presented in Table 1. The ratios from the carbon target were chosen as a worst case scenario due to their slightly larger values when compared to the ratios from the hydrogen target. Fig. 2 (a)-(d) presents the simulated particle event distributions for C 4 F 10 at P = 0.25atm. The blue histogram represents the distribution for the number of detected photo-electrons (p.e.) for 200000 electron events whereas the red histogram represents the distribution for the number of

4 Momentum p (GeV/c) π/e Ratio Angle θ (deg) 1.5 230 35 3.0 20 20 5.0 0.36 17 7.0 0.0039 17 Table 1: Extrapolated π/e ratios for carbon at the simulated momenta detected p.e. for the scaled (detected pion events π/e ratio) pion events. From our simulation, at P = 0.95atm and p = 7GeV/c (not shown) the average p.e. per electron event is 54 and the full width at half maximum (fwhm) is 33 p.e. In Fig. 2 (a)-(d), it can be seen that the average number of detected p.e. is 17 with a fwhm of 9 p.e. There is no significant change in the shape of the distribution from P = 0.95atm to P = 0.25atm. However, the average number of detected p.e. has decreased significantly from 54 to 17. At P = 0.25atm, the false pion detection distribution spreads across 20 p.e. which exceeds the average detected p.e. of 17 for the electron events. One needs to evaluate the electron inefficiency in addition to the false pion detection efficiency to optimize the detector performance in order to perform e/π separation. The electron detection inefficiency is calculated as: i e = 1 500 i dx npe 200000 (1) and the false pion detection efficiency due to knock-on electrons is calculated as: e π = 500 i dy npe 200000 (2) where x is the detected electron events per p.e. bin, y is the detected pion events per p.e. bin, i is the p.e. threshold, and the upper integral limit of 500 indicates the last histogram bin of our p.e. distribution. We computed the electron detection inefficiency and false pion detection inefficiency for every threshold position and plotted them together as seen in Figs. 2 through 5 (e)-(h). This allowed for the determination of the optimal threshold cut which is defined as the point where the pion and electron curves intersect on the scaled figure. It should be noted that there are two sources

5 of p.e. detection inefficiency when referring to the detected events: (1) the missed pion or electron events due to optical mis-focussing, absorption, etc. which is independent of the p.e. threshold cut; and (2) the events which occur below the p.e. threshold cut. Our goal is to achieve greater than 98% electron detection efficiency with the least amount of false pion detection efficiency possible (less than 1.5%). Note that in Fig. 2 (e) the optimal threshold cut at 9.2 p.e. yields 96.7% electron detection efficiency with 3.3% false pion detection efficiency which is lower than our target efficiency. See Fig. 3 for comparison of the simulations with C 4 F 10 at P = 0.50atm. This rules out the possibility for the use of C 4 F 10 at P 0.25atm to perform e/π separation for p < 3GeV/c with the HGC detector. A lower detector operating pressure is needed to achieve good e/π separation. However, the average detected p.e. will decrease. From our calculations, the Cherenkov threshold momentum for pion events in C 4 F 10 at P = 0.25atm is p = 4.6GeV/c. The pion p.e. distribution (red) shown in Fig. 2 (a)-(b) is a result of the delta radiation created by a knock-on electron induced by a sub-threshold pion event. (c)-(d) of Fig. 2 displays the primary Cherenkov radiation distribution produced by above-threshold pion events. Moving to the CO 2 simulations, as shown in Fig. 4 (a)-(d), the average detected p.e. for each electron event is 10 and the fwhm is 6 p.e. The false pion detection distribution spreads across 10 p.e. compared to 20 for the C 4 F 10 results at P = 0.25atm. It can also be seen that the width of the electron detection distribution is narrower than that of C 4 F 10. Fig. 4 (e)-(h) shows that for all four simulated momenta, an electron detection efficiency exceeding 99% is achieved. The false pion detection efficiency is less than 0.3% for 3GeV/c, 5GeV/c, and 7GeV/c while for 1.5GeV/c it is 1.0%. Compared to the simulation for CO 2 at P = 0.75atm in Fig. 5, an electron detection efficiency exceeding 98.5% is achieved for all four simulated momenta at P = 0.75atm. Similarly, the false pion detection efficiency is less than 1.5% for 1.5GeV/c and 5GeV/c while for 3GeV/c and 7GeV/c it is less than 0.4%. We recommend a cut at 3.6 p.e. to achieve the optimal electron detection efficiency and false pion detection efficiency for all momenta at an operating pressure of P = 0.50atm.

6 (a) C 4 F 10 @ P = 0.25atm & p = 1.5GeV/c (b) C 4 F 10 @ P = 0.25atm & p = 3GeV/c (c) C 4 F 10 @ P = 0.25atm & p = 5GeV/c (d) C 4 F 10 @ P = 0.25atm & p = 7GeV/c (e) C 4 F 10 @ P = 0.25atm & p = 1.5GeV/c (f) C 4 F 10 @ P = 0.25atm & p = 3GeV/c (g) C 4 F 10 @ P = 0.25atm & p = 5GeV/c (h) C 4 F 10 @ P = 0.25atm & p = 7GeV/c Figure 2: (a)-(d) Scaled particle event distribution. The blue distribution represents the detected p.e. distribution for 200000 electron events whereas the red distribution represents the detected p.e. for the scaled (detected pion events π/e ratio) pion events. (e)-(h) False pion detection efficiency and electron detection inefficiency. The blue curve represents the electron inefficiency with respect to the p.e. threshold. The red curve represents the scaled (Eqn. 2 π/e ratio) false pion detection efficiency with respect to the p.e. threshold. The point of intersection defines the optimal threshold cut.* *refer to text for further detail

7 (a) C 4 F 10 @ P = 0.50atm & p = 1.5GeV/c (b) C 4 F 10 @ P = 0.50atm & p = 3GeV/c (c) C 4 F 10 @ P = 0.50atm & p = 5GeV/c (d) C 4 F 10 @ P = 0.50atm & p = 7GeV/c (e) C 4 F 10 @ P = 0.50atm & p = 1.5GeV/c (f) C 4 F 10 @ P = 0.50atm & p = 3GeV/c (g) C 4 F 10 @ P = 0.50atm & p = 5GeV/c (h) C 4 F 10 @ P = 0.50atm & p = 7GeV/c Figure 3: Refer to Fig. 2 for further information.

8 (a) CO 2 @ P = 0.50atm & p = 1.5GeV/c (b) CO 2 @ P = 0.50atm & p = 3GeV/c (c) CO 2 @ P = 0.50atm & p = 5GeV/c (d) CO 2 @ P = 0.50atm & p = 7GeV/c (e) CO 2 @ P = 0.50atm & p = 1.5GeV/c (f) CO 2 @ P = 0.50atm & p = 3GeV/c (g) CO 2 @ P = 0.50atm & p = 5GeV/c (h) CO 2 @ P = 0.50atm & p = 7GeV/c Figure 4: Refer to Fig. 2 for further information.

9 (a) CO 2 @ P = 0.75atm & p = 1.5GeV/c (b) CO 2 @ P = 0.75atm & p = 3GeV/c (c) CO 2 @ P = 0.75atm & p = 5GeV/c (d) CO 2 @ P = 0.75atm & p = 7GeV/c (e) CO 2 @ P = 0.75atm & p = 1.5GeV/c (f) CO 2 @ P = 0.75atm & p = 3GeV/c (g) CO 2 @ P = 0.75atm & p = 5GeV/c (h) CO 2 @ P = 0.75atm & p = 7GeV/c Figure 5: Refer to Fig. 2 for further information.

10 These results suggest that CO 2 will provide a better combination of good electron identification efficiency and poor pion identification efficiency compared to C 4 F 10. At low pressure (P = 0.25atm) and p > 3GeV/c, e/π separation is possible using C 4 F 10 although the number of detected p.e. per incident electron is less favourable. Overall, CO 2 has the greatest optimized performance at P = 0.50atm and a threshold cut at 3.6 p.e. This yields a detected electron efficiency greater than 98.98% and a false pion detection efficiency less than 1.02% for all simulated momenta. All recommended HGC operating pressures presented in this report are based on the assumption of a π/e production ratio of π/e = {230, 20, 0.36, 0.0039} at the simulated momenta of p = {1.5GeV/c, 3.0GeV/c, 5.0GeV/c, 7.0GeV/c} respectively. It is recommended to contact Dr. Garth Huber prior to setting the detector pressure.