PMT Charge Response and Reconstruction of Position and Energy for a Reactor θ 13 Experiment

Similar documents
Hands on Project: Large Photocathode PMT Characterization

Overview Physical processes PMT and electronics response Some results Plans

The Factors That Limit Time Resolution for Photon Detection in Large Cherenkov Detectors

Monte Carlo Simulations for Future Geoneutrino Detectors

nerix PMT Calibration and Neutron Generator Simulation Haley Pawlow July 31, 2014 Columbia University REU, XENON

arxiv:physics/ v1 3 Aug 2006

Next Generation Scintillation Detectors: Development of Quantum Dot Doped Scintillator. Lindley Winslow University of California Los Angeles

A method to measure transit time spread of photomultiplier tubes with Cherenkov light

Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere. 1 Introduction

Scintillation Detector

The relevance of XENON10 constraints in this low-mass region has been questioned [15] C.E. Aalseth et al. arxiv: v1

KamLAND. Introduction Data Analysis First Results Implications Future

PoS(PD07)031. General performance of the IceCube detector and the calibration results

SHMS Aerogel Detector & Calorimeter Status. A. Mkrtchyan

Direct WIMP Detection in Double-Phase Xenon TPCs

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Radioactivity and Ionizing Radiation

Nuclear Physics and Astrophysics

Performance of the MCP-PMT for the Belle II TOP counter

David B. Cassidy. Department of Physics and Astronomy, University of California, Riverside, USA. Varenna, July 09

arxiv: v1 [physics.ins-det] 3 Feb 2011

PARTICLES REVELATION THROUGH SCINTILLATION COUNTER

Radiation (Particle) Detection and Measurement

MEASURING THE LIFETIME OF THE MUON

Neutron pulse height analysis (R405n)

1 Introduction. KOPIO charged-particle vetos. K - RARE Meeting (Frascati) May Purpose of CPV: veto Kl

arxiv:astro-ph/ v1 15 Feb 2005

GEANT4 simulation of the testbeam set-up for the ALFA detector

A MONTE CARLO SIMULATION OF COMPTON SUPPRESSION FOR NEUTRON ACTIVATION ANALYSIS. Joshua Frye Adviser Chris Grant 8/24/2012 ABSTRACT

STUDY ON THE ENERGY RESPONSE OF PLASTIC SCINTILLATION DETECTOR TO MEV NEUTRONS ABSTRACT

Measurements of Liquid Scintillator Light Yield for Future Neutrino Experiments

Counting Photons to Calibrate a Photometer for Stellar Intensity Interferometry

LOW ENERGY SOLAR NEUTRINOS WITH BOREXINO. Lea Di Noto on behalf of the Borexino collaboration

Time-of-Flight PET using Cherenkov Photons Produced in PbF 2

XENON Dark Matter Search. Juliette Alimena Columbia University REU August 2 nd 2007

Synthesis of plastic scintillator. Ildefonso León Monzón Universidad Autónoma de Sinaloa

GEANT4 Simulation of Pion Detectors for the MOLLER Experiment

Nuclear Physics Laboratory. Gamma spectroscopy with scintillation detectors. M. Makek Faculty of Science Department of Physics

COMPTON SCATTERING OF GAMMA RAYS

arxiv: v1 [physics.ins-det] 27 Jun 2017

Validation of Geant4 Physics Models Using Collision Data from the LHC

PoS(PSTP 2013)034. Precession Polarimetry at JLab, 6 GeV. G.B. Franklin Carnegie Mellon University

Simulation Results for CLAS12 From gemc

High resolution neutron spectrometry with liquid scintillation detectors for fusion applications

Particle Detectors. How to See the Invisible

Simulations for H.E.S.S.

Study of the Scintillation Detector Efficiency and Muon Flux

PoS(TIPP2014)093. Performance study of the TOP counter with the 2 GeV/c positron beam at LEPS. K. Matsuoka, For the Belle II PID group

DETERMINING FUNDAMENTAL PARAMETERS OF A SINGLE-PHOTOTUBE LIQUID SCINTILLATION COUNTER

Measurements of liquid xenon s response to low-energy particle interactions

Investigation of a Cs137 and Ba133 runs. Michael Dugger and Robert Lee

Test bench for measurements of NOvA scintillator properties at JINR D.S. Velikanova, 1 A.I. Antoshkin, 1 N.V. Anfimov, 1 O.B.

Design, Construction, Operation, and Simulation of a Radioactivity Assay Chamber

PoS(KAON09)023. Beam Hole Photon Veto For J-PARC K O TO experiment. Yosuke Maeda Kyoto University

Science of Nuclear Energy and Radiation a Comprehensive Course for Science Teachers June 22-25, 1998 McMaster University

Nuclear Recoil Scintillation and Ionization Yields in Liquid Xenon

Polarization Correlation in the Gamma- Gamma Decay of Positronium

PHYS 5326 Lecture #6. 1. Neutrino Oscillation Formalism 2. Neutrino Oscillation Measurements

Lucite Hodoscope for SANE

Chapter 4 Scintillation Detectors

University of Michigan Physics : Advanced Laboratory Notes on RADIOACTIVITY January 2007

PHYS 3650L - Modern Physics Laboratory

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

NA62: Ultra-Rare Kaon Decays

Error Budget in π + e + ν Experiment

XMASS: a large single-phase liquid-xenon detector

Monte Carlo programs

GLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY

Detection and measurement of gamma-radiation by gammaspectroscopy

Status report on parity violation in the (1232) resonance

III. Energy Deposition in the Detector and Spectrum Formation

Compton Camera with PositionSensitive Silicon Detectors

The Neutron/WIMP Acceptance In XENON100

Neutron Transport Calculations Using Monte-Carlo Methods. Sean Lourette Fairport High School Advisor: Christian Stoeckl

Calibration of the AGILE Gamma Ray Imaging Detector

Recent Activities on Neutron Standardization at the Electrotechnical Laboratory

LENA. Investigation of Optical Scintillation Properties and the Detection of Supernovae Relic Neutrinos. M. Wurm. January 18, 2006 LENA. M.

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

EEE4106Z Radiation Interactions & Detection

Search for sterile neutrinos at the DANSS experiment

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

Comparison of the Photo-peak Efficiencies between the Experimental Data of 137 Cs Radioactive Source with Monte Carlo (MC) Simulation Data

The H.E.S.S. Standard Analysis Technique

LXe (part B) Giovanni Signorelli. Istituto Nazionale di Fisica Nucleare, Dipartimento di Fisica and Scuola Normale Superiore, Pisa (Italy)

G4 vs. Fluka comparison for single neutron

Lecture 16 Light transmission and optical detectors

Calibration of the Modular Neutron Array (MoNA)

The HEX Anti-Coincidence Detector

SciBar and future K2K physics. F.Sánchez Universitat Aútonoma de Barcelona Institut de Física d'altes Energies

Studies of Hadron Calorimeter

Searches for sterile neutrinos at the DANSS experiment. Dmitry Svirida for the DANSS Collaboration ITEP-JINR

XENON100. Marc Schumann. Physik Institut, Universität Zürich. IDM 2010, Montpellier, July 26 th,

THE COMPTON EFFECT Last Revised: January 5, 2007

arxiv: v1 [physics.ins-det] 29 Jun 2011

arxiv:hep-ex/ v1 22 Apr 2002

Solar Neutrino Oscillations

First Stage Analysis of the Energy Response and Resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008

Paolo Agnes Laboratoire APC, Université Paris 7 on behalf of the DarkSide Collaboration. Dark Matter 2016 UCLA 17th - 19th February 2016

KamLAND. Studying Neutrinos from Reactor

Mass hierarchy determination in reactor antineutrino experiments at intermediate distances. Promises and challenges. Petr Vogel, Caltech

Transcription:

PMT Charge Response and Reconstruction of Position and Energy for a Reactor θ 13 Experiment Josh Klein April 11, 2004 1 Introduction I have taken a first look at the effects of the PMT charge response on position and direction reconstruction for the baseline θ 13 detector. Unlike a water Cerenkov detector, the long time tail on the scintillator s response is likely to make PMT charge response in a reactor experiment more important than time response. While the question of how well the tubes need to measure charge is a relatively minor one compared to the critical questions of background levels, detector stability and calibration, and number of detector zones, it has the nice feature that it is probably one we can actually answer quickly. I have used Kansas s ReactorFsim for the investigation presented here, modified to include a more realistic charge spectrum, based upon the measured response of the SNO PMTs (Hammamatsu R1408). The distribution of ReactorFsim is whatever was current as of January 27, 2004. 2 Charge Spectrum The charge resolution of a PMT is driven primarily by the gain of the first dynode, because it is here that the electron statistics are lowest. Depending upon the tube, the average gain at the first dynode may be 2 or 3, though some high resolution tubes can be as high as 5. The poisson statistics of these small numbers of secondary electrons leads to a broad 1

Figure 1: Single pe Distribution for SNO PMTs (Hammatsu R1408 s) charge response, which is made only broader as the signal propagates through additional stages. Beyond the statistical broadening, interactions within the tube can add to the gain (thus broadening it further). Examples of these interactions are photoelectrons scattering off of the focusing grid or other tube elements; bremstrahlung photons which produce additional photoelectrons as they reach the photocathode; or ionization of gas within the PMT. Variations in gain from tube-to-tube, if not well calibrated and corrected, will also lead to broadened charge resolution. Lastly, whatever smearing is inherent in the front-end electronics integration (and/or digitization) can broaden things slightly as well. Figure 1 shows the average single pe spectrum averaged over roughly half of the SNO PMT s, measured in ADC counts above pedestal. The data here were taken in gated mode in which the integrators are gated in-time with light from a laser source placed at the center of the SNO detector. The pedestal peak down at low charge represents all the times in which a photon was not incident upon a photocathode, and so the charge integral is zero. Note in particular the tail on the charge spectrum, which continues out well past the single pe peak, and which is caused by some of the effects mentioned above. To create a charge response which looks like this charge distribution, I picked a somewhat ad-hoc analytic form, fitted to the spectrum. The analytic form uses a Polya distribution to 2

represent the single pe shape: P(m) = m(mq)m 1 e mq (1) Γ(m) where Q is measured in units of photoelectrons. I also added an exponential to represent the high charge tail, and to turn off the exponential term near pedestal, I include a factor which is just an exponential rise (an RC curve). The fit to this analytic form is superimposed on the charge histogram of Figure 1, fitted from about the single pe peak (at around 25 counts above pedestal) to 60 counts above pedestal. The χ 2 for the fit is not particularly good, but for the purposes here the spectrum looks realistic enough. Unfortunately, it is very hard to fit the spectrum below the single pe peak, because the pedestal peak interferes quite a bit. Discriminated (rather than gated) data could be used instead, but then the resulting spectrum is discriminator-threshold dependent. For a full hit-level Monte Carlo, we ultimately will want to include the discriminator threshold efficiencies, and so I have tried to start with the full single pe spectrum here. To include this charge distribution in ReactorFsim, I added a method to the ReactorDetector class called GetQ, which takes as input the number of photoelectrons created on a given tube, and returns the measured charge in units of equivalent pe. For npe photoelectrons, the charge spectrum is sampled npe times and the charges added and convolved with a gaussian to represent the smearing of the front end electronics. Figure 2 shows the charge distribution generated by GetQ for a single photoelectron (the cutoff at about 6 pe is artificial and was removed for the rest of the study). Figure 3 shows the charge spectra for single and multiple photoelectrons, compared to the generated number of pe. 3 Position Reconstruction ReactorFsim includes a simple position reconstruction algorithm, essentially a fitter in closed form which calculates the dipole moment of the charge distribution, and a second stage which provides some improvement on the initial fit. For the baseline detector, position reconstruction is likely to be used only through a r cut between the positron and neutron positions in order to remove accidental backgrounds, and therefore may not be too critical. Nevertheless, we would expect that a smearing of the charge resolution will have a noticeable 3

Figure 2: Simulated single pe charge spectrum Figure 3: Number of photoelectrons compared to charge spectra 4

Figure 4: Position resolution in the x dimension, with and without the smearing due to realistic PMT charge response effect on a position reconstruction algorithm based on charge alone. Figure 4 shows the position resolution in the x coordinate for positrons, with and without the PMT charge smearing. We see that the resolution is broadened a bit (roughly 2 cm, from 9.5 cm to 11.5 cm) from the PMT charge response, which is not too bad. To see the effects on a potential r cut, I plot in Figure 5 the difference in position of the positron and neutron in an event, with and without the effects of charge smearing. We see that the distribution shifts slightly, by roughly 5 cm. To know how big an effect this is on background rejection, we d need to know the distribution of accidentals in r, which will depend on their source accidentals from γ-rays making it to the scintillator will be peaked at high r (and therefore this is a very small effect), while radioactivity inside the scintillator will be flat. However, at first look, this does not seem too bad of an effect. One additional variable worth considering here is photocathode coverage. The charge smearing means that two PMT hits are worth more than 2 pe in one PMT you know if there are two PMT s hit, that you have at least 2 pe, whereas with just one tube you do not. Figure 6 shows the same r distribution as shown in Figure 5, but for a detector with a 10% photocathode coverage (as compared to the 20% used earlier). We see that in the lower coverage detector the difference between the reconstruction of events with perfect and smeared charges is larger, but not too bad: the shift in the reconstruction of r is perhaps 5

Figure 5: Distribution of reconstructed distance between positron and neutron, with and without the smearing due to realistic PMT charge response gone from 5 cm to 8 or 9 cm. 4 Energy Reconstruction ReactorFsim also includes an algorithm to reconstruct the event energies, which uses the input photocathode coverage, quantum efficiencies, and the energy scale itself (number of photons per MeV). The reconstructed energy is therefore proportional to the observed number of photoelectrons, and we expect that the smearing out of the charge measurements by real tubes will have a noticeable effect on the reconstructed energy spectrum. Figure 7 shows a comparison between the reconstructed energy spectrum for the default ReactorFsim simulation (no PMT charge smearing) and the same spectrum with the charge smearing described in Section refsec:qspec. What we see is that not surprisingly the energy spectrum with the smeared charges is about 25% broader than that without. The apparent shift in the mean is just a consequence of the fact that the energy scale (the number of photons per MeV) has not been change to equivalent pe per MeV which is a smaller number due to the charge smearing. To see if a low photocathode coverage detector is affected more than a high photocathode coverage detector, I looked at both a 10% coverage detector and a 1% coverage. The 10% 6

Figure 6: Distribution of reconstructed distance between the positron and neutron for a 10% coverage detector. Figure 7: Reconstructed energy spectrum with and without charge smearing. 7

detector looked no different, which is somewhat surprising. This may be a consequence of the parameterized way ReactorFsim handles hits, but I would have to look at this some more. 5 Conclusions The conclusion to all this is not at all suprising: better charge resolution is better. However, I still think we need to look at this a bit more with a hit-level Monte Carlo like the recent Geant4 studies being done at Kansas, since I would like to have a better idea of how the distribution of PMT hits (as opposed to PMT charge) affects things. 8