Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Similar documents
IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 30 Bars (up to DN1") Specifications : Anti blow-out stem PTFE packing Full bore

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

DN 1/4" to 4" Male, Female BSP - 10 C C Max Pressure : 40 Bars Specifications : Anti blow-out stem PTFE packing Full bore.

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

JDV CONTROL VALVES CO., LTD. JCT/JCTM Series 3/4 Way Trunnion Type Valve Manual

Pneumatic Universal. Actuator MOTORIZED VALVES USE TECHNICAL FEATURES OF THE ACTUATOR. Data sheet

The 505F Series 3/4/5-Way Ball Valve. Standard Features and Benefits. Operating Conditions. Specifications. Options

Globe Valve, Metal. Sectional drawing. *see information on working medium on page 2

VOLUMEC. Valve Position Indicator 5

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Cooling Water Flow Regulator

1.7 Z 411 WAFER TYPE BUTTERFLY VALVE Z 411 TECHNICAL DATA

1.2 Z 014-A LUG TYPE BUTTERFLY VALVE Z 014-A TECHNICAL DATA:

Direct-operated 2/2-way compact solenoid valves Type EV210A

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

PR CYCLONE SECONDARY SHUTOFF

Standardized Chemical Pumps. Fields of Application. Designation. Design. Operating Data. Type Series Booklet /7-10 G2 CPK-H

1.2 Z 014-A LUG TYPE BUTTERFLY VALVE Z 014-A TECHNICAL DATA

2.3 T214 PTFE-LINED BUTTERFLY VALVE T 214 TECHNICAL DATA

CV3000 Series. Characterized Insert Control Valves

3.2 HP 114 HIGH PERFORMANCE BUTTERFLY VALVE HP 114 TECHNICAL DATA

Pressure independent balancing and control valve AB QM DN

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2.

2.3 T 214-A TECHNICAL DATA

WAFER PATTERN BUTTERFLY TYP Z 011-A

Application PN 16 / 40 DN Product features. Compact overall height Body shape gives optimum flow characteristic

Bettis RGS F-Series. Quarter-Turn Spring-Return (SR) and Double-Acting (DA) Pneumatic Actuators. Product Data Sheet RGS Rev.

3.1 HP 111 HIGH-PERFORMANCE BUTTERFLY VALVE HP 111 TECHNICAL DATA

barmesapumps.com SELF-PRIMING CENTRIFUGAL TRASH PUMP SPECIFICATIONS Series: SH8-U Suction: 8" Discharge: 8" Spherical solids handling: 3"

Type M4 - SON - SO - MS

2.1 T211 PTFE-LINED BUTTERFLY VALVE T 211 TECHNICAL DATA

2.1 T 211-A TECHNICAL DATA

VD1 CLC. Small Valves DIN-range with a higher k v -value

HEAVY DUTY SWING-OUT VALVE

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

HEAVY DUTY SWING-OUT VALVE

Conversion Kit for: 7620 and 7820 Swing-Out Valves ft-lbs ft-lbs 8835/ ft-lbs

DMHP3(4)L(T)2A00 Series

/2" Heavy Duty Swing-Out

hard anodized aluminum extrusion die cast aluminium acetalic resin nickel plated steel die cast aluminium nitrile rubber stainless steel 3 Version

Solenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design

Made in Italy HOSE REELS CATALOGUE TECHNOLOGY FOR FLUIDYNAMICS. No. E14/A1

Pressure independent balancing and control valve AB QM DN

Solenoid valves 2/2-way direct-operated type EV210A

AME Model. (1) Rated flow (l/min (ANR)) Port size (Nominal size B) Weight (kg)

Inspired By Challenge. Trunnion mounted ball valves

Ball Valves. Ball Valves

Direct-operated 2/2-way solenoid valves Type EV210B

Contents. Identification LHC. Horizontal split case pumps. Type key. Identification Type key

EX-EMERGENCY LIGHT FITTINGS

ED 701 General Industry Pressure Transmitter

Flow rates to 750 l/min

ø6, ø10, ø15, ø20, ø25, ø32, ø40, ø50, ø63 How to Order Switch rail Nil Standard stroke Refer to page 12 for standard stroke.

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

ProPress (304 FKM) 1.3

ORTHOBLOC 3000 Drive systems Maintenance

BELGICAST is a company of. Soft Sealing Gate Valves

Standardized Chemical Pumps to EN /ISO 2858/ISO 5199 sealless, with magnetic drive. Fields of Application. Designation. Design.

Flow rates to 750 l/min

G-FIRE FLANGE ADAPTERS

Pressure independent balancing and control valve AB QM DN

Conductivity sensor for hygienic applications

98 Series Backpressure Regulators and Relief Valves

Odor Removal Filter Series AMF

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

Flow rates to 475 l/min

LES. Single-stage end-suction pumps Identification Type key

PN LINE. PN Line. PX Line. PA Line. PU Line PX LINE. PV Line PA LINE & TUBINGS PU LINE PV LINE. Brass Push-in fittings

RIMA OFFICIAL CATALOGUE CATALOGUE TP

Nickel-Plated Brass Push-In Fittings - NPTF/INCH

THE ANSWER TO PROBLEMS OF: CORROSION, ABRASION, GRANULATED MATERIALS, POWDERS, SLUDGE, GAS ETC.

flexible couplings for pipe repair

G-FIRE GROOVED FITTINGS

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

1 Input data. Profis Anchor Company: Specifier: Address: Phone I Fax: Page: Project: Sub-Project I Pos. No.

1 Input data. Profis Anchor Company: Specifier: Address: Phone I Fax: Page: Project: Sub-Project I Pos. No.

507F. Multi-Port Sanitary Ball Valve. Full Port ISO 5211 Mounting Pad. For Automated & Manual Service. Pharmaceutical. Bio-Technology.

Flow rates to 485 l/min

xanik API 6D Trunnion Ball Valves

IL series. Centrifugal marine IN-LINE pumps

Orifice Plate. Stainless Steel. Flow Data. Herz Valves UK Ltd.

PLOW MOUNT KIT FOR POLARIS RANGER P/N ASSEMBLY / OWNERS MANUAL

Cooler-Bypass Thermostat Valve, Size 10

K Series SIGHT GLASS FOR CONVENIENT OBSERVATION OF LIQUID FLOW GENERAL

Precision Ball Screw/Spline

VISUAL LEVEL INDICATORS

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Flow Meter FVone-NP-CA. FVone-NP-CA 11 (Plug-in type) (Screw-in type) Recommended for: DN 20 DN 80 Required accessory: Cable type 31.

411 Steel Couplings. 411 Steel Couplings--Standard Length Sleeves 1/2 thru 12 Steel Pipe Sizes. Sleeve Thk. X Lgth. In.

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS

M O D U L E - 3A Model A10V0 Piston Pump Manual A10V0 PUMP. Features

Cartridge Valves Technical Information. Quick reference

MR medium rating busbar

SL27C SL32C. ScreenLine. Technical Catalogue. english. double-glazed unit 27 mm 32 mm

Transcription:

erie B. Flanged ductile iron ball valve BRanDOni made in E U R O P E Application fields WATER CONdITIONING GA EATING INdUTRY FIRE FIGTING www.brandoni.it

erie B. eries B. valves are shut-off ball valves split-body type in ductile iron and floating ball, manufactured according to the severe product standards and the quality management relative to IO 900. uitable for heating and conditioning (VAC), district heating, distribution and treatment of water, industrial application, agricultural application, for compressed air processing, for oils and hydrocarbon. (Please ensure the choice of the corresponding item) YE: for installation in line and end of line, for services with frequent acting, the integrated IO support allows the installation of a wide range of actuators. The B. range of ball valves are full and straight bore reducing turbulences and minimizing head loss. NO: for steam, for choking and flow regulation.. Inside and outside epoxy coating, high temperature resistant. Environmentally friendly, water-based paint.. Integrated flange, in accordance with IO.. Removing and repositioning of the plate at 90 allows locking of the valve in ON-OFF position. 4. The dynamic seal of the stem is guaranteed by a double O-ring, even in severe working conditions.. Blow-out proof stem. 4. eat of ball in reinforced PTFE, as temperature changes, the torque remains constant.. Ball with full and straight bore, in chromed brass or stainless steel. Accessories Actuators tem extension for thermal insulation quare cap for water main system connection tem extension Kit IO flange Kit lockable operation lever Kit limit switches for ON/OFF position indicator Refer to specifications on page double acting and single acting pneumatic actuators On request: limit switches, position indicator Electric actuators Gear box pecial items Through-drilled ball for legionella thermal preventive treatment drainage plug In conformity with directive 9//CE PEd Conformity to EN 4 norms, DVGW certification for gas Construction and testing norms (correspondences): Face-to-face: EN/ (IO ) Flanges: EN09, ANI B. #0 design: EN 9, EN44, IO Marking: EN9 Testing: 00% testing in accordance with EN cat. A (IO 0 cat. A) www.brandoni.it 9

Flanged ductile iron ball valve B. - DN - 0 C 0 9 B E IO n x q 4 A DN -0 P J B.0/B. - DN 00 9 B IO n x q E C 4 A P J B.0/B. - DN 0 B V T Key 4x0 IO R / DINA E IO n c q C C 4 A 4 P J 0 www.brandoni.it

erie B. Materials 4 9 0 4 Component Body Flange Ball Ball seat tem liding washer Ring O-Ring Lever top plate pring washer Lever hub Lever stop Anti-blow-out ring Mounting pad for gear box Gear box Bolts : only DN 00-0 * : DN 0 with ball in EN GJL 0 - CODE: 0.040 ** Material EN GJ 400- / EN GJL0*, epoxy coated EN GJ 400- / EN GJL0*, epoxy coated Brass CuZn40Pb chrome plated / AII 04 / AII / EN GJL0** Reinforced PTFE Brass CuZn40Pb / AII 04 / AII PTFE Brass CuZn40Pb / AII 04 / AII NBR /FKM (Viton ) Carbon steel, epoxy coated Galvanized carbon steel Galvanized carbon steel EN GJ 400- Galvanized carbon steel AII 0 EN GJ 400- / EN GJL 0 - Galvanized carbon steel Dimensions (mm) DN 0 40 0 0 00 0 00 0*** P 0 40 0 9 0 4 90 40 A (B.) EN / - 4 (ex DIN 0 F4) 0 0 40 0 0 0 90 00 0 - - A (B.0) EN / - 4 (ex DIN 0 F) - - - - - - - - - - - 400 40 A (F.) EN / - 9 (ex NF 9-) - - - - 4 4 0 00 - - 4 4 9 0 4 0 4 0 44 0, 9 4, 9,, 0 B 0 0 0 0 0 0 0 0 0 40 0 000 0 C EN09/ PN 9 0 40 0 00 0 0 40 40 C - - - - - - - - - - - - 490 V - - - - - - - - - - - - 00 T - - - - - - - - - - - - 4 IO F04 F04 F04 F04 F0 F0 F0 F0 F0 F0 F0 F J 4 4 4 4 0 0 0 0 0 0 0 n x Ø q 4 x 4 x 4 x 4 x 4 x 4 x 4 x 4 x 9 4 x 9 4 x 4 x 4 x 4 x E,, 4, 4,,,, 0 0 4, 4, 9 o 9 o 9 o o o 4 o 4 o 4 o o o o o Ø 4 Weight (kg) B.00,, 4,,, 9 0,,,, 9 0 B. - B.,, 4,,, 9,,,,, 4, 0 Operating torque (Nm) Nm 0 40 0 00 0 0 00 000 N.B.: In order to choose the right actuator, we recommend multiplying the operating torque figure by a safety coefficient, K=. : The diameter DN 0 is supplied with gear box as standard *** Drilling DN 0 40 0 0 00 0 00 0 Drilling PN EN09/ std std std std std std std std std std std std std Dimensions Drilling PN 0 EN09/ = = = = = = = = = = = opt opt of flanges Drilling PN EN09/ opt opt opt opt opt opt opt opt opt opt opt opt opt according to Drilling PN EN09/ = = = = = = opt = no no no no no PN EN09/ Drilling ANI B. #0 opt opt opt opt opt opt opt opt opt* opt opt opt opt std: standard / opt: option on request / =: same as PN www.brandoni.it

Flanged ductile iron ball valve Maximum pressure Temperature Fluids * azardous gases azardous liquids All remaining fluids Mounting BETWEEN FLANGE ENd OF LINE bar dn-00 0 bar dn0 bar dn-00 0 bar dn0 bar dn-00 0 bar dn0 *: azardous gas, liquids (explosive, inflammable, toxic) in accordance with 9//CE PED and /4/EEC Pressure/temperature chart 0 bar dn-00 NO DN-0 0 bar 0 bar Temperature min C Max C continuous peak NBR -0 00 0 FKM (Viton ) -0 0 0 NB: the maximum working pressure decreases while temperature increases, please refer to pressure/temperature chart -4 04 40 4 4 0 F bar psi 0 90 0 4. bar Liquid - steam saturation line (fluid: water) bar. bar - -0 0 0 40 0 0 00 0 40 0 0 C RANGE NOT UITABLE FOR TEAM. DO NOT use when temperature and pressure are below the liquid-steam saturation line ( hatched area ) ead loss Fluid: water (m O = 0,09bar) mmo/m DN DN 0 DN DN DN 40 DN 0 DN DN 0 DN 00 DN DN 0 DN 00 DN 0 000 00 0 0 00 000 mc/h Kv - DN chart DN 0 40 0 0 00 0 00 0 Kv mc/h, 4,, 0,4 4 94 0 4 9 00 www.brandoni.it

erie B. Versions O-Ring: NBR b.00 Ball: Brass CuZn40Pb tem: Brass CuZn40Pb Temp: -0 +00 C b.0 tem: Brass CuZn40Pb Temp: -0 +00 C b. Temp: -0 +00 C b. Ball: AII Temp: -0 +00 C Available with item code b.0 for dimensions DN 00 0 b.000 b.00 b.0 b.0 Body: EN GJL 0 Body: EN GJL 0 Body: EN GJL 0 Body: EN GJL 0 Available with item code F Face to face in accordance with EN /-9 (ex NF 9-) F.00 F.0 F. F. ee: B.00 ee: B.0 ee: B. ee: B. Coating: RAL 00 colour For Gas b.00 Gas b.0 Gas b. Gas b. Gas Ball: Brass CuZn40Pb tem: Brass CuZn40Pb Temp: -0 +0 C tem: Brass CuZn40Pb Temp: -0 +0 C Temp: -0 +0 C Ball: AII Temp: -0 +0 C Coating: RAL 00 colour O-Ring: FKM * b.00 FKM b.0 FKM b. FKM b. FKM Ball: Brass CuZn40Pb tem: Brass CuZn40Pb O-ring: FKM Temp: -0 +0 C tem: Brass CuZn40Pb O-ring: FKM Temp: -0 +0 C O-ring: FKM Temp: -0 +0 C Ball: AII O-ring: FKM Temp: -0 +0 C Coating: RAL 00 colour pecial versions on request * Most suitable for district heating for water up to 0 C www.brandoni.it

Ball valves Accessories for series B - B. - B./ tem extension for thermal insulation DN 40-0- 0-00--0 A W IO n x q E B T quare cap for water main system connection DN 40-0- 0-00 -0 W A 4 9 9 tem extension for water main system connection DN 40 0 0 00 0 0-00-00-000 T 4 4 4 4 4 9 9 B 0 0 0 0 0 40 0 IO F0 F0 F0 F0 F0 F0 F0 J 0 0 0 0 0 0 0 n x Ø q 4 x 4 x 4 x 4 x 9 4 x 9 4 x 4 x E 4 4 4 Kit IO flange W IO ) Bracket ) Joint Y X Emax DN -0-40-0-0 00 0 IO * F04-0-0 F04-0-0 F0-0 F0- F0- F0- F0- -4 x E 4 x 4 x x x X X X x E** x x - - - - - Drilling valve side F0-04 F0-04 F0-0 F0-0 F0-0 F0-0 F0- -4 X 40 40 0 0 0 0 0 Y 0 0 0 0 0 0 40 W 0 0 00 0 0 0 0 * Drilling actuator side ** for B series Other top squares on request Kit lockable operation lever Kit limit switches for ON/OFF position indicator www.brandoni.it

Instructions and Recommendations for series B - B. - B./ erie B - B The information provided here is delivered with each product, and contains Instructions for use and maintenance ; it is also available on our website: www.brandoni.it (download section) TORING - Keep in a dry and closed place. - While stored, the valve must be fully open to avoid damage to the seats. MAINTENANCE - It is recommended that the rubber O-rings be replaced at least every 4 months, and the PTFE seats, at least every 4 months. The period of replacement depends on the use of the valve. - Clean the surface of the valve periodically, in order to prevent the accumulation of dust. RECOMMENDATION Before carrying out maintenance, or dismantling the valve, be sure that the pipes, valves and liquids have cooled down, that the pressure has decreased and that the lines and pipes have been drained in case of toxic, corrosive, inflammable or caustic liquids. Temperatures above 0 C and below 0 C might cause damage to people. INTALLATION - andle with care. The valve must be installed in either the ON or OFF position. - Place the valve between the flanges of the pipe and install the seal between the pipe and valve flanges. Check the correct position of the seals. - The distance between the counter flanges should be equal to the valve s face to face distance. Do not use bolts of the counter flanges to bring the piping close to the valve. The bolts should be cross tightened. - Do not weld the flanges to the piping after installing the valve. - Water hammers might cause damage and ruptures. Inclinations, torsions and misalignments of the piping may subject the installed valve to excessive stresses. It is recommended that elastic joints be used in order to reduce such effects as much as possible. - While heating from room temperature to the high operating temperature, the liquid located between the body and ball (valve open), or located in the bore of the ball (valve closed) tends to expand and may damage the ball and the seats; it is recommended that the valve be opened and closed at intermediate temperatures during the heating process (for example, at 40 C /0 C/ ). pecial valves with drain plugs are available for this application. - At sub-zero temperatures, the liquid between the body and ball may freeze, causing irreparable damage. If the valve is exposed to such conditions, insulation of the valve is recommended. - It is recommended that the valve be operated periodically, to prevent the build-up of materials on the ball and the seats, particularly in the presence of limestone. EALING Plumbing PROCEDURE procedure Plate in plumbing position; it is not possible to open/close the valve. Open valve Closed valve www.brandoni.it