Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Similar documents
HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Targeted protein quantification

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Fitting of ETD Rate Constants for Doubly and Triply Charged Ions in a Linear Ion Trap

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Detection of Mycotoxins in Corn Meal Extract Using Automated Online Sample Preparation with Liquid Chromatography-Tandem Mass Spectrometry

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis

Introduction to Fourier Transform Infrared Spectroscopy

for XPS surface analysis

High-Throughput LC-MS/MS Quantification of Estrone (E1) and Estradiol (E2) in Human Blood Plasma/Serum for Clinical Research Purposes

An Evaluation of Various High-Resolution, Accurate-Mass Scan Modes for In Vitro Drug Discovery Screening

Fast, Effective XPS Point Analysis of Metal Components

Screening Method for 30 Pesticides in Green Tea Extract Using Automated Online Sample Preparation with LC-MS/MS

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

of mass spectrometry

High-Field Orbitrap Creating new possibilities

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites

Quan/Qual Analyses. Unmatched Confidence for. Thermo Scientific Q Exactive Orbitrap LC-MS/MS System. Identify Quantify Confirm

Charles Yang, Dipankar Ghosh, Jonathan Beck Thermo Fisher Scientific, San Jose, CA, USA

MetWorks Metabolite Identification Software

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Introduction to Fourier Transform Infrared Spectroscopy

Peptide Targeted Quantification By High Resolution Mass Spectrometry A Paradigm Shift? Zhiqi Hao Thermo Fisher Scientific San Jose, CA

Relative quantification using TMT11plex on a modified Q Exactive HF mass spectrometer

HILIC Method Development in a Few Simple Steps

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Quantitation of a target protein in crude samples using targeted peptide quantification by Mass Spectrometry

Exploring Mixed-Mode Chromatography Column Chemistry, Properties, and Applications

High-Resolution Accurate-Mass (HRAM) Phthalate Screening using Direct Analysis in Real Time (DART) Ambient Ionization

The Raman Spectroscopy of Graphene and the Determination of Layer Thickness

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

Monitoring Protein PEGylation with Ion Exchange Chromatography

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Direct Analysis using Paper-Spray Mass Spectrometry: Method Development for the Rapid Screening of Drugs of Abuse for Forensic Toxicology

Quantitation and Characterization of Copper Plating Bath Additives by Liquid Chromatography with Charged Aerosol Detection

Fast Protein and Peptide Separations Using Monolithic Nanocolumns and Capillary Columns

Key Words Q Exactive Focus, Orbitrap, veterinary drugs, small molecule HRAM quantitation, small molecule HRAM screening, UHPLC, vdia

Increasing the Multiplexing of Protein Quantitation from 6- to 10-Plex with Reporter Ion Isotopologues

Quantitative and Qualitative Confirmation of Pesticides in Beet Extract Using a Hybrid Quadrupole-Orbitrap Mass Spectrometer

A Platform to Identify Endogenous Metabolites Using a Novel High Performance Orbitrap MS and the mzcloud Library

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

Determination of urea in ultrapure water by IC-MS/MS

Designed for Accuracy. Innovation with Integrity. High resolution quantitative proteomics LC-MS

Improved 6- Plex TMT Quantification Throughput Using a Linear Ion Trap HCD MS 3 Scan Jane M. Liu, 1,2 * Michael J. Sweredoski, 2 Sonja Hess 2 *

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

Measurement of Metabolic Stability Using SIM and Identification of Metabolites by Data Dependent Full-Scan MS/MS and CNL Scanning

LC-MS/MS Analysis of Phytocannabinoids and their

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

IN QUALITATIVE ANALYSIS,

Comparison of Solid Core HPLC Column Performance: Effect of Particle Diameter

XPS Surface Characterization of Disposable Laboratory Gloves and the Transfer of Glove Components to Other Surfaces

ApplicationNOTE A STUDY OF THE ANALYSIS OF POLYBROMINATED DIPHENYL ETHER FLAME RETARDANTS BY GC/MS/MS. Introduction. Materials and Methods

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Determination of BTEX in Cigarette Filter Fibers Using GC-MS with Automated Calibration

Improving Experimental Efficiency for Drug Metabolite Profiling and Identification

Validation of GC-MS/MS for Detection and Confirmation of Low-Level Dioxins

Semi-Targeted Screening of Pharmaceutically- Related Contaminants in the Thames Tideway using LC-HRMS

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Improving Intact Antibody Characterization by Orbitrap Mass Spectrometry

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Thermo Finnigan LTQ. Specifications

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

The Agilent 6495 Triple Quadrupole LC/MS: Peptide Quantitation Performance

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Chemical Labeling Strategy for Generation of Internal Standards for Targeted Quantitative Proteomics

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM

Automated and accurate component detection using reference mass spectra

Key Words Nanoparticles, spicp-ms, ICP-MS, Qtegra ISDS Software, AF4-ICP-MS

Enhancement of Linearity and Response in Charged Aerosol Detection

HR/AM Targeted Peptide Quantitation on a Q Exactive MS: A Unique Combination of High Selectivity, Sensitivity and Throughput

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

Transcription:

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer Reiko Kiyonami, Mary Blackburn, Andreas FR Hühme: Thermo Fisher Scientific, San Jose, CA, USA

Overview Purpose: Demonstrate increased sensitivity, throughput, and reproducibility for targeted protein quantification in biologically complex samples using a new triple stage quadrupole instrument and Thermo Scientific Pinpoint 1.3 software. Methods: Thermo Scientific TSQ Quantiva triple stage quadrupole mass spectrometer equipped with a Thermo Scientific EASY-Spray source were used for all experiments. A dilution series containing enzymatic digest mixtures of BSA and Enolase spiked in E. coli digest matrices were used to evaluate the improved quantitative performances and reproducibility of the new instrument. A separate sample set was used to evaluate the quantitative accuracy while applying the new triple stage quadrupole instrument to more complex samples. Pinpoint 1.3 software was used for rapid selected reaction monitoring (SRM) assay development based on discovery data and data processing. Results: The new instrument design improved SRM assay sensitivity, reproducibility, and linear dynamic range significantly. Both BSA and Enolase were detected at 1 attomol on column with excellent reproducibility. Five orders of linear dynamic range was observed. Pinpoint software allowed rapid SRM assay development and refinement for targeted proteins. Pinpoint software also allowed automatic data processing for quantifying protein expression ratios between two different sample groups with good precision. Introduction The triple stage quadrupole instrument-based SRM method has emerged as the method of choice for targeted protein quantification. In order to accurately quantify proteins of interest from complex biological samples in which the concentration of targeted proteins could change over six-orders of magnitude, high sensitivity and wide dynamic range are required. In most cases, sample-specific peptide standards that can be used for SRM assay development may not be available. It is critical to have software that enables rapid SRM assay development utilizing previous discovery data. Here we report that a new triple stage quadrupole instrument was able to push detection limits of targeted proteins down to the 1-attomol level with five orders of linear dynamic range. We also demonstrate that an optimized SRM assay to quantify 12 proteins from E. coli complex matrices could be developed in a few hours using Pinpoint software relying on data previously acquired in the discovery phase of the project. Methods Sample Preparation Sample Set 1: A sample dilution series that spiked BSA and Enolase digest mixture into 10 ng E. coli digest matrix at six different concentration levels (0.0005 fmol/µl, 0.005 fmol/µl, 0.05 fmol/µl, 0.5 fmol/µl, 5 fmol/µl, 50 fmol/µl) were prepared. Sample Set 2: Two E. coli digest complex samples (A and D) that contain 12 protein standards with different concentration ratios were prepared. Sample A was prepared by spiking 12 protein standard digests into 500 ng E. coli matrices at a static concentration level of 5 fmol/µl. Sample D was prepared by spiking 12 protein standard digests into 500 ng E. coli matrix at three different concentration levels of 0.5 fmol/µl, 5 fmol/µl and 50 fmol/µl. Nano-LC: System: Thermo Scientific EASY-nLC 1000 liquid chromatograph Separation Column: EASY-Spray column (50 µm ID 15 cm) MA: 0.1% FA-H2O MB: 0.1%FA-MeCN Gradient: 5%B 45%B in 40 min Flow rate: 300 nl/min Injection amount: 2 µl 2 Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Mass Spectrometry: Instrument: TSQ Quantiva MS with an EASY-Spray nano source Spray voltage: 1800 V Sheath gas: 0 Auxiliary gas: 0 Capillary T: 275 C Collision gas: Ar, 1.5 mtorr Q1 and Q3 resolution: 0.7 Da Cycle time: 1.5 sec; CE=0.03 m/z of precursor ion + 6.0 SRM: Non-scheduled for initial SRM assay development Scheduled SRM with 2 min scheduled time window for the refined SRM assay Data Analysis: Thermo Scientific Xcalibur 2.2 and Pinpoint 1.3 software were used for all data processing. Results Quantitative Performances Acquired From the BSA-Enolase Dilution Series By implementing a novel ion source and optics with active ion management (AIM) technology with a 10% imbalance in the RF amplitude applied to the hyperbolic quadrupoles, the new instrument improved detection sensitivity significantly. Both BSA and Enolase peptides were clearly detected at 10 attomol levels on column in 10 ng of complex E. coli matrix (Figure 1). In combination with the innovative EASY-Spray nano source, the signal intensity variations from run-to-run were very small and the observed percentage of coefficient of variation was less than 7%, even at low attomol concentration levels (Figure 2). With a completely redesigned ion detection system, the dynamic range of the new instrument has also been improved significantly. Figure 3 shows that the calibration curve generated from the BSA peptide of AEFVEVTK for which five orders of linear dynamic range was observed. FIGURE 1. Extracted chromatograms of BSA peptide of LVNELTEFAK and Enolase peptide of NVNDVIAPAFVK from the dilution series (0.0005 fmol/µl) Thermo Scientific Poster Note PN ASMS13_W479_RKiyonami_e 06/13S 3

FIGURE 2. The %CV for peptide LVNELTEFAK from BSA and for peptide NVNDVIAPAFVK from Enolase for the low attomol injections of the dilution series FIGURE 3. Calibration curve of spiked BSA peptide LVNELTEFAK. Over 5-orders of linear dynamic range was observed. Rapid SRM Assay Development and Refinement Using Pinpoint Software The new triple stage quadrupole instrument was applied to determine the differential ratios of 12 proteins spiked in 500 ng of complex E. coli matrices for sample A and sample D. The SRM assay development and refinement were carried on using Pinpoint 1.3 software and previous 12 protein identification results. Figure 4 shows the steps to develop the initial SRM assay relying on the discovery data and refine the final SRM assay using the data from the initial SRM assay. Only two HPLC MS/MS runs were required to generate the final SRM assay for quantifying the 12 protein targets from both samples. The optimized final SRM assay was used for both sample A and sample D. Each sample was run in triplicate. Pinpoint software was used to process all the data and calculate the group ratios between sample A and sample D and the %CV of each targeted peptides (Figure 5). The calculated differential group ratios of each targeted protein between sample A and sample D are shown in Figure 6. The observed differential ratios are consistent with the expected ones. The calculated %CVs were all less than 15% (Figure 6). 4 Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

FIGURE 4. SRM development workflow using Pinpoint 1.3 software Step 1: Develop initial SRM assay by selecting all identified peptides from the previous discovery experiments. Step 2: Generating the initial SRM assay by selecting top six detected y-type fragment ions for each peptide from the discovery data. The new instrument allows 500 SRM transitions per second, providing rapid initial SRM assay development by running 1000 unscheduled transitions in a single HPLC run. Step 3: Refinement of SRM assay by automatically selecting up to top 5 detected peptides per protein from the initial run. All transitions are scheduled automatically for the refined SRM assay. Thermo Scientific Poster Note PN ASMS13_W479_RKiyonami_e 06/13S 5

FIGURE 5. Automatic data processing using Pinpoint 1.3 software FIGURE 6. Observed differential ratio of each targeted protein between samples A and D. The observed differential ratios are in good match with the expected ratios. Conclusion Low attomol LOD/LOQ of targeted proteins in complex biological samples was achieved with a new triple stage quadrupole instrument demonstrating ultimate sensitivity for peptide quantification. Excellent reproducibility with %CV better than 6.5 was observed even at low attomol concentration levels. In excess of five-orders of linear dynamic range was observed for a peptide in the presence of a complex matrix. In combination of Pinpoint 1.3 software and fast SRM scan speed of the new triple stage quadrupole instrument, an optimized SRM assay to quantify 12 proteins in complex E. coli matrix was developed in a few hours requiring only two iterative experiments. Precise relative quantification results were observed using a rapidly developed SRM assay in four iterations of optimization using Pinpoint software. 6 Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

www.thermoscientific.com 2013 Thermo Fisher Scientific Inc. All rights reserved. ISO is a trademark of the International Standards Organization. All other trademarks are the property of Thermo Fisher Scientific, Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Thermo Fisher Scientific, San Jose, CA USA is ISO 9001:2008 Certified. Africa-Other +27 11 570 1840 Australia +61 3 9757 4300 Austria +43 1 333 50 34 0 Belgium +32 53 73 42 41 Canada +1 800 530 8447 China +86 10 8419 3588 Denmark +45 70 23 62 60 Europe-Other +43 1 333 50 34 0 Finland/Norway/Sweden +46 8 556 468 00 France +33 1 60 92 48 00 Germany +49 6103 408 1014 India +91 22 6742 9434 Italy +39 02 950 591 Japan +81 45 453 9100 Latin America +1 561 688 8700 Middle East +43 1 333 50 34 0 Netherlands +31 76 579 55 55 New Zealand +64 9 980 6700 Russia/CIS +43 1 333 50 34 0 South Africa +27 11 570 1840 Spain +34 914 845 965 Switzerland +41 61 716 77 00 UK +44 1442 233555 USA +1 800 532 4752 ASMS13_W479_RKiyonami_E 06/13S