Measuring fusion excitation functions with RIBs using the stacked target technique: Problems and possible solutions

Similar documents
A new analysis procedure to extract fusion excitation function with large beam energy dispersions: application to the 6 Li+ 120 Sn and 7 Li+ 119 Sn

Inclusive breakup measurements of the 7 Li+ 119 Sn system.

PROTON-PROTON FEMTOSCOPY AND ACCESS TO DYNAMICAL SOURCES AT INTERMEDIATE ENERGIES

Sub-barrier fusion of Si+Si systems : does the deformation of 28 Si play a role?

New application of the quasi-free reaction mechanism to study neutron induced reactions at low energy

Isospin influence on Fragments production in. G. Politi for NEWCHIM/ISODEC collaboration

The nuclear matrix elements of 0νββ decay and the NUMEN project at INFN-LNS

Measurement of the plasma astrophysical S factor for the 3 He(D, p) 4 He reaction in exploding molecular clusters

Density and temperature of fermions and bosons from quantum fluctuations

Improvements in data analysis obtained by large-area silicon E-E detector telescopes

Determination of lifetimes of nuclear excited states using the Recoil Distance Doppler Shift Method in combination with magnetic spectrometers

Fusion of 9 Li with 208 Pb

Scattering of He on Pb at energies around the Coulomb barrier

arxiv: v1 [physics.ins-det] 11 Mar 2010

Neutron detection efficiency from the 7 Li(p,n) reaction (R405n)

Isospin influence on the decay modes of compound nuclei produced in the 78,86 Kr + 40,48 Ca at 10 MeV/nucleon

CHARGED PARTICLE INTERACTIONS

Recent experiments in inverse kinematics with the magnetic spectrometer PRISMA

Testing the shell closure at N=82 via multinucleon transfer reactions at energies around the Coulomb barrier

The 22 Ne(α,n) 25 Mg reaction at astrophysical energies studied via the Trojan Horse Method applied to the 2 H( 25 Mg, α 22 Ne) 1 H reaction

SIMULATION OF LASER INDUCED NUCLEAR REACTIONS

High order corrections to density and temperature of fermions and bosons from quantum fluctuations and the CoMD-α Model

Neutron-rich rare isotope production with stable and radioactive beams in the mass range A ~ at 15 MeV/nucleon

Large electron screening effect in different environments

Study of the break-up channel in 11 Li+ 208 Pb collisions at energies around the Coulomb barrier

X-ray superburst ~10 42 ergs Annual solar output ~10 41 ergs. Cumming et al., Astrophys. J. Lett. 559, L127 (2001) (2)

Neutron Transport Calculations Using Monte-Carlo Methods. Sean Lourette Fairport High School Advisor: Christian Stoeckl

M. De Napoli, F. Giacoppo, G. Raciti, E. Rapisarda, C. Sfienti. Laboratori Nazionali del Sud (LNS) INFN University of Catania. IPRD Oct.

The rotational γ -continuum in the mass region A 110

Dependence on neutron energy of neutron induced peaks in Ge detectors. E. Gete, D.F. Measday B.A. Moftah, M.A. Saliba, T.J. Stocki

Preliminary results of the indirect study of the 12 C( 12 C,α) 20 Ne reaction via the THM applied to the 16 O( 12 C,α 20 Ne )α reaction

Fast proton bunch generation in the interaction of ultraintense laser pulses with high-density plasmas

Study of the Dynamical Dipole Resonance Mode with the SPES Radioactive Beams

Electron scattering in large water clusters from photoelectron imaging with high harmonic radiation

PRE-EQUILIBIRUM α-particle EMISSION AS A PROBE TO STUDY α-clustering IN NUCLEI

Measurement of secondary particle production induced by particle therapy ion beams impinging on a PMMA target

Sub-barrier fusion enhancement due to neutron transfer

He+ 6,7 Li and 6 He+ 12 C reactions. Matko Milin Ruđer Bošković Institute Zagreb, Croatia

PRE-EQUILIBRIUM α-particle EMISSION AS A PROBE TO STUDY α-clustering IN NUCLEI

PoS(ENAS 6)050. Resonances in 19 Ne with relevance to the astrophysically important 18 F(p,α) 15 O reaction

Accreting neutron stars provide a unique environment for nuclear reactions

Search for 24 Mg resonances inside the Gamowwindow for 12 C+ 12 Cfusion. Neven Soić, Ruđer Bošković Institute, Zagreb, Croatia

Absorption and Backscattering ofβrays

Recent results on the 11 B(p,α) 8 Be reaction studied through the THM: S(E)-factor and electron screening measurements

Citation EPJ Web of Conferences (2014), provided the original work is prope

Study of multi-nucleon transfer reactions with light nuclei

News from the MAGNEX-EDEN facility at the LNS

BRIDGING OVER p-wave π-production AND WEAK PROCESSES IN FEW-NUCLEON SYSTEMS WITH CHIRAL PERTURBATION THEORY

Characterization of quasi-projectiles produced in symmetric collisions studied with INDRA Comparison with models

Measurements of the gamma-quanta angular distributions emitted from neutron inelastic scattering on 28 Si

Studies on 3D Fusion Reactions in TiDx under Ion Beam Implantation

What is Spallation???

Supplementary Figure S1 Definition of the wave vector components: Parallel and perpendicular wave vector of the exciton and of the emitted photons.

Evidence for core excitation in single-particle states of 19 Na

Microscopic description of 258 Fm fission dynamic with pairing

DIPOLE-STRENGTH IN N=50 NUCLEI STUDIED IN PHOTON-SCATTERING EXPERIMENTS AT ELBE

Isospin symmetry breaking in mirror nuclei. Experimental and theoretical methods

Why the complete fusion of weakly bound nuclei is enhanced at sub-barrier energies and suppressed above the barrier?

Nuclear contribution into single-event upset in 3D on-board electronics at moderate energy cosmic proton impact

Distinctive features of Coulomb-related emissions in peripheral heavy ion collisions at Fermi energies

Radioactivity III: Measurement of Half Life.

Temperature measurements of fusion plasmas produced by petawatt laser-irradiated D 2-3 He or CD 4-3 He clustering gases

Michigan State University, East Lansing MI48824, USA INTRODUCTION

Elastic, inelastic and inclusive alpha cross sections in 6 Li+ 112 Sn system

III. Energy Deposition in the Detector and Spectrum Formation

Presence of Barrier Distributions in Heavy Ion Fusion

Megan E. Bennett, Dmitriy A. Mayorov, Kyle D. Chapkin, Marisa C. Alfonso, Tyler A. Werke, and Charles M. Folden III

First indication of LPM effect in LHCf, an LHC experiment

An Analytical Approach is Developed to Estimate the Values of Range of Alpha Particles Emitted from Radon Gas

Noncentral collisions

Use of fragmentation beams at LNS with CHIMERA detector

Fitting Function for Experimental Energy Ordered Spectra in Nuclear Continuum Studies

(Multi-)nucleon transfer in the reactions 16 O, 3 32 S Pb

Scattering of halo nuclei on heavy targets at energies around the Coulomb barrier

Electron screening effect in nuclear reactions and radioactive decays

Report on the benchmarking of the event generator for fusion-evaporation reactions

GA A24166 SUPER-INTENSE QUASI-NEUTRAL PROTON BEAMS INTERACTING WITH PLASMA: A NUMERICAL INVESTIGATION

Neutron-Induced Reactions Investigations in the Neutrons Energy Range up to 16 MeV

Reaction dynamics and exotic systems: a focus on fast processes

4. Rotational motion in thermally excited nuclei *

Rotational motion in thermally excited nuclei. S. Leoni and A. Bracco

Thursday, April 23, 15. Nuclear Physics

Neutron pulse height analysis (R405n)

Extracting spectroscopic information from ( 18 O, 16 O) two-neutron transfer reactions. Manuela Cavallaro INFN -LNS (Italy)

Neutron Activation Cross Sections for Fusion

APPLICATION OF THE NUCLEAR REACTION ANALYSIS FOR AGING INVESTIGATIONS

Evaluation of inclusive breakup cross sections in reactions induced by weakly-bound nuclei within a three-body model

Week 2: Chap. 2 Interaction of Radiation

Multilayer Nuclear Track Detectors for Retrospective Radon Dosimetry

Lab1. Resolution and Throughput of Ion Beam Lithography.

Physics of particles. H. Paganetti PhD Massachusetts General Hospital & Harvard Medical School

Gamma-ray emission by proton beam interaction with injected Boron atoms for medical imaging. Giada Petringa - Laboratori Nazionali del Sud -

Response function of the magnetic spectrometer PRISMA

Study and comparison of the decay modes of the systems formed in the reactions

arxiv:nucl-ex/ v1 21 Jun 2001

Physics 1C. Lecture 28D

A pattern recognition method for the RICH-based HMPID detector in ALICE

EPJ Web of Conferences 31, (2012) DOI: / epjconf/ C Owned by the authors, published by EDP Sciences - SIF, 2012

Passage of Charged Particles in matter. Abstract:

Nonstatistical fluctuations for deep inelastic processes

Transcription:

Measuring fusion excitation functions with RIBs using the stacked target technique: Problems and possible solutions M. Fisichella 1,A.C.Shotter 2,A.DiPietro 1,P.Figuera 1, M. Lattuada 1,3,C.Marchetta 1, V. Privitera 4,L.Romano 3,4, C. Ruiz 5 and M. Zadro 6 1 INFN - Laboratori Nazionali del Sud, via S. Sofia 62, I-95123 Catania, Italy 2 School of Physics and Astronomy, University of Edinburgh, JCMB, Mayfield Road, Edinburgh EH9 3JZ, UK 3 Dipartimento di Fisica ed Astronomia, via S. Sofia 64, I-95125 Catania, Italy 4 CNR-IMM MATIS, via S. Sofia 64, Catania, Italy 5 TRIUMF, 4004 Wesbrook Mall, Vancouver, BC V6T 2A3, Canada 6 Ruder Bošković Institute, Bijenička cesta 54, HR-10000 Zagreb, Croatia Abstract For measuring fusion excitation functions, the activation technique with a stack of targets offers the considerable advantage that several reaction energies may be simultaneously measured by using one beam energy. However, its main drawback is the degradation of the beam quality as it passes through the stack due to statistical nature of energy loss processes and any non-uniformity of the stacked targets. If not taken properly into account, this degradation can lead to a wrong determination of the fusion excitation function. In this contribution some results of the investigation of this problem are reported. The Authors, published by EDP Sciences - SI F. This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0/).

1 Introduction In the last decades, many fusion reactions induced by low intensity RIBs have been studied by irradiating stacks of several thick targets and measuring on-line or off-line the radiation emitted in the decay of the evaporation residues [1 7]. In these activation experiments, the fusion excitation function has been determined by associating the cross-section σ mean (E), measured in each target, either with the energy of the beam in the middle of the considered target Ē or to the effective energy E eff, defined as follows: E eff = 0 0 Eσ(E)D(E,t 0 )de σ(e)d(e,t 0 )de In the last definition, the value of the energy is obtained by an averaging procedure which weights the beam energy with energy distribution D(E,t 0 ) inside the considered target of thickness t 0 together with the trend of the fusion cross sections. The D(E,t 0 ) distribution represents the probability that a beam particle will have energy E inside the considered target of thickness t 0. The physical factors that influence the shape of the energy distribution function D(E,t 0 ) are the shape of the beam energy distribution entering the target, the beam energy loss in the target, and the energy straggling of the beam. The D(E,t 0 ) distribution taking esplicitly into account all the above effects, can be determined by using the SRIM code [9] as discussed in [8]. The present authors found that neither Ē nor E eff lead to the correct reconstruction of the fusion excitation function. In particular, it has been found that in the case of an uniform target Ē is an underestimation and E eff is an overestimation, respectively, of the real value E r, defined as the reaction energy such that σ mean = σ(e r ), where σ(e) is the true cross section function. As an example it was supposed to know the behaviour of the 9 Li+ 120 Sn fusion excitation function and it was supposed that at subbarrier energies it has an exponential trend with a slope α=1.72 MeV 1, which is within the range of typical slopes observed in sub-barrier fusion experimental data. We considered an incoming energy beam of 17 MeV and calculated analitically the values of E r, Ē and E eff as a function of the energy losses in the target (i.e., targets of different thicknesses). The results are reported in figure 1 in the case of a delta incoming beam energy distribution (Fig.1a) and Gaussian incoming beam energy distribution with FWHM = 2 MeV (Fig.1b). Only for the ideal case of a mono-energetic beam and for thin targets will E r, Ē, ande eff coincide. In this example uniform (1) 2

Figure 1: Calculations for the 9 Li+ 120 Sn system. Ē, E eff and E r are plotted as a function of the energy loss in the target for an average incident beam energy is 17 MeV. a) Delta beam energy distribution; b) Gaussian beam energy distribution with FWHM=2 MeV. See text for details. targets have been considered, but it has to be noticed that the presence of non-uniformities in the target will further modify this behaviour, as it will be shown in the following section. The present authors developed an alternative deconvolution procedure to determine the correct fusion excitation function of the studied system. The idea is to determine an analytical expression for σ(e) such that for the D(E,t 0 ) associated to each given target one would obtaion by using Eq. 3 the measured mean cross section. Details about this new method are reported in [8]. Application of this procedure requires a detailed knowledge of D(E,t 0 ). The best way to determine D(E,t 0 ) is to characterise target properties, as well as performing numerical beam energy loss simulations. Of course, these effects are amplified when a stack of targets is used. For this reason, an accurate analysis has been done concerning the the target non-uniformity and the effect that this could have on the determination the fusion excitation function. It has been developed an experimental technique based on simple measurements of residual energy spectra of α emitted by an 231 Am source from which it is possible to determine in a very accurate way the target thickness distribution [8]. 2 9 Li+ 120 Sn simulation Generally, in the previous articles where these kind of experiments are discussed, very few information are given about target non-uniformity, straggling effects and incident beam quality. However, as discussed previously, 3

since these factors can significantly influence the deduced excitation functions the present authors performed simulations in order to investigate in details how they might influence the determination of the fusion excitation function and try to quantify the magnitudes of these effects. Numerical simulations of the 9 Li+ 120 Sn fusion reaction have been performed. It has been supposed that a 28 MeV 9 Li beam impinged on a stack of five targets each composed of one 120 Sn foil with an average thickness of 5 mg/cm 2, followed by an uniform 93 Nb catcher/degrader foil 1.5 mg/cm 2 thick. The results of the simulations were studied for the case of uniform targets and degrader foils, and for the situation where both targets and foils are non-uniform. The 9 Li+ 120 Sn fusion excitation function behaviour has been supposed to be known and to have a Wong-like behaviour: σ(e) = A E ln(1 + eb(e C) ) (2) with A=1936 mb MeV, B=1.83 MeV 1, C=18.95 MeV. The chosen parameters in the Eq.(2) are consistent with the cross-section slopes of other similar reactions. In this way, for each target, the mean cross-section that would be measured in it has been calculated by using the following relation: σ mean = 0 0 σ(e)d(e,t 0 )de D(E,t 0 )de As an example, in Fig. 2a the D(E,t 0 ) distributions of the fitht target obtained by the SRIM simulation for the case of uniform (continuos line) and non-uniform (dotted line) stack foils are reported. As it is possible to see, not only the shapes but also the explored energy ranges of the distributions are different in the two cases. In Fig. 2b the σ mean obtained by applying Eq. (3) for the uniform and nonuniform target cases, is plotted versus the mean energy Ē (open symbols), and versus the effective energy E eff (closed symbols). The circles and triangles correspond to case of uniform and non-uniform target, respectively. It has to be put in evidence that the cross-section values that would be measured for the two cases are slightly different due to the different energy distributions inside the targets. The continuous line represents the cross-section of Eq. (2) assumed to represent the real behavior of the fusion excitation function in the simulated experiment. As one can see, at energies below the Coulomb barrier, the real excitation function is not reproduced by any of the two representations. The differences are bigger in the case of non-uniform targets with respect to the uniform case, as one can expect due to the wider energy distributions D(E,t 0 ). Plotting the measured (3) 4

10 3 10 2 fus (mb) 10 1 mean vs E - UNIFORM mean vs E eff - UNIFORM mean vs E - NON-UNIFORM mean vs E eff - NON-UNIFORM 10-1 10-2 12 14 16 18 20 22 24 26 28 E Lab (MeV) Figure 2: a) Energy distribution of the beam inside the fifth target of the stack considering uniform (continuous line), and non uniform (dotted line) foils. b) Results of the simulations for the case of uniform (circles) and for non-uniform (triangles) targets. The continuous black line shows the real fusion excitation function assumed for the collision 9 Li+ 120 Sn. The open and closed symbols are the experimental results that would be obtained plotting the measured σ mean versus Ē and E eff.in this figure the results of the deconvolution procedure cannot be distinguished from the black line. The blue shaded area represent the uncertainty associated with the deconvolution procedure. See text for details. cross-sections versus Ē or E eff generates differences up to a factor of 5 with respect to the real fusion excitation function. The deconvolution procedure, developed by the present authors, has also been applied to these simulated data. For applying this procedure a typical error on the measured mean cross-section, σ mean,ineachofthe targets, has been supposed to be 15%. This error would originate from experimental uncertainties associated with detector efficiencies, mean target thickness, target thickness distribution etc. The results obtained with this procedure cannot be distinguished from the continuum line representing the assumed real cross-section. The shaded blue area represents the error band associated with the procedure. This error band has been calculated by applying the standard error propagation formula to Eq. 2, considering the three parameters (A,B,C) as free variables. According to the present results the best way of determining the fusion excitation function is to use the deconvolution procedure. 5

3 Summary and conclusion From the present study it is clear that that the traditional way to represent the fusion cross section as function of the energy in the middle of the target, or as a function of an effective energy based on a weighted average which takes into account both the beam energy distribution and the energy dependence of the cross section, may lead to a wrong determination of the fusion excitation function, especially when the energy distribution within a target is large, and the cross-section is rapidly changing with the energy. The present authors suggest as a possible solution to infer the true excitation function, to apply a deconvolution procedure as discussed in previous paragraph. In order properly apply this procedure a detailed knowledge of the the target thickness distribution and of the incoming beam distribution beam must be available. Therefore the authors recommend that for future publications where such data is presented, enough information should be included concerning the used foil non-uniformities, beam energy distribution and their effects on the deduced fusion excitation functions. References [1] J. J. Kolata, et al., Phys. Rev. Lett. 81, 4580 (1998). [2] P. A. DeYoung, et al, Phys. Rev. C 58, 34423444 (1998). [3] Y. Penionzhkevich, et al., The European Physical Journal A 31, 185194 (2007). [4] A. Lemasson, et al., Phys. Rev. Lett. 103, 232701 (2009). [5] Y. E. Penionzhkevich, et al, Phys. Rev. Lett. 96, 162701 (2006). [6] C. Signorini, et al, Nuclear Physics A 735, 329 344 (2004). [7] R. Wolski, et al., The European Physical Journal A 47, 111 (2011). [8] M. Fisichella et al., Accepted for publication in Phys. Rev. C [9] J. Ziegler, Srim code - http://www.srim.org. [10] C. Y. Wong, Phys. Rev. Lett. 31, 766769 (1973). 6