UPDATE on: Consistency for water vapour of GRUAN, LBLRTM and IASI

Similar documents
GRUAN and Satellite Collocation Xavier Calbet - EUMETSAT

IASI Level 2 Product Processing

Outcomes of a workshop aimed at improved understanding of biases found in analysis of 183 GHz observations

Spatial and inter-channel observation error characteristics for AMSU-A and IASI and applications in the ECMWF system

Comparison of GRUAN profiles with radio occultation bending angles propagated into temperature space

Change management for the RS92 phase out

Lead Centre report. Ruud Dirksen, GRUAN Lead Center. Meteorological Observatory Lindenberg. ICM-7 23 February 2015

GRUAN management of transition away from RS92 radiosonde summary of developments to date

Satellite Sounding Characteristic Performance Versus Radiosonde, Impact of Local Overpass Time and Uncertainty

Operational IASI Level 2 Processing

The AMSU/MSU FCDR as an in-orbit reference for monitoring ATMS

Reference quality upper-air measurements: GRUAN data processing for the Vaisala RS92 radiosonde

GRUAN Site Report for La Réunion

From Space-Based Measurements to Climate Data Records

Kernel-Based Retrieval of Atmospheric Profiles from IASI Data

Jun Park National Meteorological Satellite Center Korea Meteorological Administration

Direct radiance validation of IASI - results from JAIVEx

Climate Monitoring with GPS RO Achievements and Challenges

GATNDOR TopicCollocation Uncertainty in Vertical Pro les:statistical Functional Regression Approach

GRUAN-wide strategy for the transition away from the RS92 radiosonde

IASI L1 NRT data quality monitoring at EUMETSAT Lars Fiedler, Yakov Livschitz, Denis Blumstein, Eric Pequignot, Tim Hultberg and Francois Montagner

A physically-based observation error covariance matrix for IASI

IASI RADIANCES CLIMATOLOGY. Thierry PHULPIN* and Joaquin GONZALEZ** *Now at TIRSEC **Now at CNES/DLA

Monitoring and Assimilation of IASI Radiances at ECMWF

Working Together on the Stratosphere: Comparisons of RO and Hyperspectral IR Data in Temperature and Radiance Space

13B.2 COMPARISON OF SELECTED IN-SITU AND REMOTE SENSING TECHNOLOGIES FOR ATMOSPHERIC HUMIDITY MEASUREMENT

Anonymous Referee #2 In black => referee observations In red => our response. General comments

RIVAL Field Campaign at the ENA, NSA, & SGP ARM Sites

Site Report: Lauder, New Zealand

Long-Term Time Series of Water Vapour Total Columns from GOME, SCIAMACHY and GOME-2

Direct assimilation of all-sky microwave radiances at ECMWF

The Meisei sonde data product

The GEWEX water vapor assessment (G-VAP) - results from inter-comparisons and stability analysis

AN INVESTIGATION INTO THE PERFORMANCE OF RETRIEVALS OF TEMPERATURE AND HUMIDITY FROM IASI

Lessons learnt from the validation of Level1 and Level2 hyperspectral sounders observations

Impact of IASI assimilation in convective scale model AROME

Evaluation of MUSICA MetOp/IASI tropospheric water vapour profiles by theoretical error assessments and comparisons to GRUAN Vaisala RS92 measurements

Generation and assimilation of IASI level 2 products. Peter Schlüssel, Thomas August, Arlindo Arriaga, Tim Hultberg,

Cloud detection for IASI/AIRS using imagery

Virginie Capelle. On behalf of Raymond Armante (*)

GAIA-CLIM. Peter Thorne 27/4/18

Error Assessment and Validation of the IASI Temperature and Water Vapor Profile Retrievals

UPDATES IN THE ASSIMILATION OF GEOSTATIONARY RADIANCES AT ECMWF

Towards SI traceable humidity measurements with radiosondes

Cathryn Fox, Juliet Pickering Jon Murray, Alan Last.

Satellite Observations of Greenhouse Gases

Global Space-based Inter-Calibration System (GSICS) Infrared Reference Sensor Traceability and Uncertainty

Procedures to Characterize Sounding Profiles using Conventional and Reference/Dedicated Observations --- NPROVS & NPROVS+

Joint Airborne IASI Validation Experiment (JAIVEx) - An Overview

Version 7 SST from AMSR-E & WindSAT

Traceable estimates of uncertainty for climate data records

GRUAN Data Flow and RS92 Data Product v2

Assimilation of IASI data at the Met Office. Fiona Hilton Nigel Atkinson ITSC-XVI, Angra dos Reis, Brazil 07/05/08

An Overview of the UW Hyperspectral Retrieval System for AIRS, IASI and CrIS

The Vaisala Reference Radiosonde Program: First Results and Future Plans

Model errors in tropical cloud and precipitation revealed by the assimilation of MW imagery

Intercalibration between HIRS/2 and HIRS/3 channel 12 based on physical considerations

NOAA MSU/AMSU Radiance FCDR. Methodology, Production, Validation, Application, and Operational Distribution. Cheng-Zhi Zou

Inter-satellite Calibration of NOAA HIRS Level-1b Data for the Development of Climate Data Records

An assessment of Meteor-M N2 MTVZA imager/sounder data at the Met Office and ECMWF for GAIA-CLIM

An overview of the assimilation of AIRS and IASI Radiances at operational NWP Centres

The NOAA Unique CrIS/ATMS Processing System (NUCAPS): first light retrieval results

Cloudy Radiance Data Assimilation

Recent spectroscopy updates to the line-by-line radiative transfer model LBLRTM evaluated using IASI case studies

Calibration and Validation of Metop/ATOVS and AVHRR products. Éamonn McKernan (Rhea System S. A.)

Radiation Dry Bias Correction of Vaisala RS92 Humidity Data and Its Impacts on Historical Radiosonde Data

INTRODUCTION OPERATIONS

Satellite Radiance Data Assimilation at the Met Office

Overview of Post-launch CrIS SDR Calibration and Validation

CORRELATION BETWEEN ATMOSPHERIC COMPOSITION AND VERTICAL STRUCTURE AS MEASURED BY THREE GENERATIONS OF HYPERSPECTRAL SOUNDERS IN SPACE

Assimilation of Cloud-Affected Infrared Radiances at Environment-Canada

Land Surface Temperature in the EUMETSAT LSA SAF: Current Service and Perspectives. Isabel Trigo

Dual-Regression Surface and Atmospheric Sounding Algorithm for Initializing Physical Retrievals and Direct Radiance Assimilation

EUMETSAT Activities Related to Climate

UWPHYSRET an SSEC inversion package for high resolution infrared data based on LBLRTM.

EUMETSAT Satellite Data Records for Reanalysis

Sustained, Co-Ordinated Processing of Environmental Satellite Data for Climate Monitoring (SCOPE-CM)

DIAGNOSING OBSERVATION ERROR STATISTICS FOR NUMERICAL WEATHER PREDICTION

EUMETSAT GPRC Report. Jo Schmetz Tim Hewison, Sebastien Wagner, Rob Roebeling, Peter Miu, Simon Elliot, Harald Rothfuss, Bartolomeo Viticchie EUMETSAT

D. Cimini*, V. Cuomo*, S. Laviola*, T. Maestri, P. Mazzetti*, S. Nativi*, J. M. Palmer*, R. Rizzi and F. Romano*

Long-term time-series of height-resolved ozone for nadir-uv spectrometers: CCI and beyond

GSICS Traceability Statement for IASI and AIRS

On the statistical significance of climatic trends estimated from GRUAN tropospheric time series

30 Years of HIRS Cloud Observations

Atmospheric Motion Vectors: Product Guide

LAPBIAT ATMOSPHERIC SOUNDING CAMPAIGN IN 2010: UPPER AIR AND REMOTE SENSING OBSERVATIONS OF WATER VAPOR

GCOS Reference Upper- Air Network

New Radiosonde Temperature Bias Adjustments for Potential NWP Applications Based on GPS RO Data

Developments at DWD: Integrated water vapour (IWV) from ground-based GPS

Field experiments at Sodankylä

Radiative transfer modeling in the far-infrared with emphasis on the estimation of H2O continuum absorption coefficients

Comparison of NASA AIRS and MODIS Land Surface Temperature and Infrared Emissivity Measurements from the EOS AQUA platform

FIDUCEO Fidelity and Uncertainty in Climate Data Records from Earth Observation

Land Surface Temperature Measurements From the Split Window Channels of the NOAA 7 Advanced Very High Resolution Radiometer John C.

A satellite-based long-term Land Surface Temperature Climate Data Record

microwave profiler: comparisons and synergies

IRFS-2 instrument onboard Meteor-M N2 satellite: measurements analysis

Inferring Global Cloud Cover Properties and Trends from 30 years of HIRS Data

Steve Colwell. British Antarctic Survey

MEASUREMENTS AND MODELLING OF WATER VAPOUR SPECTROSCOPY IN TROPICAL AND SUB-ARCTIC ATMOSPHERES.

Transcription:

UPDATE on: Consistency for water vapour of GRUAN, LBLRTM and IASI Xavier Calbet (xcalbeta@aemet.es) Paper in press: Calbet, X., Peinado-Galan, N., Ripodas, P., Trent, T., Dirksen, R., and Sommer, M.: Consistency between GRUAN sondes, LBLRTM and IASI, Atmos. Meas. Tech. Discuss., https://doi.org/10.5194/amt-2016-344, in review, 2016. 13 June 2017 GRUAN ICM-9 2017

PRINCIPLE GRUAN RS92 Sonde RADIANCE DIFFERENCES LBLRTM COMPARISON CALC. RADIANCES IASI OBSERVED RADIANCES

Why consistency? 1. Important for climate: transforming FCDR (e.g. Radiances) into CDR of ECV (T, WV, etc.) should measure the same 2. Important for validation: if GRUAN, LBLRTM and IASI are not consistent collocation uncertainties too high to compare reasonably (Calbet, 2015, AMTD)

GRUAN 1. GRUAN stands for GCOS Reference Upper-Air Network 2. Are providing uncertainties with the measurements 3. They have also made a great effort to reduce systematic errors from the measurements Humidity measurements are very much bias free

IASI 1. IASI is a Reference for GSICS (Global Space-based Inter-calibration System) 2. Very stable and highly accurate instrument

LBLRTM 1. LBLRTM (11.2) is one of the references for RTM

GCOS Requirements From GCOS-154: Accuracy for WV 5%

Are GRUAN and IASI consistent? Immler et al. 2010: 2 2 1 m1 m2 k u u k 2 2 2

2 GRUAN and IASI Collocation (minimum σ ) Orbits close to 00Z and 12Z IASI FOVs less than 25 km and 30 min (Pugatchev et al. 2009 ACP) apart for Manus Island 2011-2013: 76 Clear Sky cases found

Consistency check Observed IASI radiances (OBS) are compared to Calculated radiances (CALC) using GRUAN Sonde profile + Radiative Transfer Model (LBLRTM 12.2) Radiance Uncertainties calculated varying GRUAN Sonde with its uncertainties using a Monte-Carlo approach. But assuming GRUAN uncertainties are completely independent between levels!! LBLRTM 12.2 is a reference RTM OBS-CALC should fall within uncertainties from Immler et al. 2010, within ±1σ IASI noise To avoid surface effects, we use highly absorptive water vapour channels only (700 hpa and up)

Consistency check: is this even possible? Can OBS-CALC fall within ±3σ IASI instrument noise (= u1)?: is this even possible? Yes! With two RS92 Sondes and a CFH Sonde. Sodankyla EPS/MetOp Campaign 2007 Calbet et al. AMT 2011

Consistency check: is this even possible? Can OBS-CALC fall within ±3σ IASI instrument noise? This would give us a clear indication that both measurements are consistent. Pending the Immler et al. 2010 test is this possible with GRUAN? GRUAN: one RS92 sonde very well processed

Radiation comparison: individual case 1/2

Radiation comparison: individual case 2/2 Water Vapour scale much smaller than 30 min., 25 km!!

Systematic Uncertainties Here we will only consider systematic uncertainties (bias) Given enough observations, their average should lie within uncertainty bounds We are assuming this can be done: collocation uncertainty is random

Radiation Bias: Final Result: Number of cases We start with 597 collocations for Manus and IASI (30 min., 25 km) According to IASI L1 flag, only 76 cases are clear After AVHRR visual inspection, of these, only 27 cases are really clear After GRUAN processing, daytime cases seem to have a dry bias. We keep only night time cases Final result of 11 cases

Radiation Bias: Final Result Night-time

Radiation Bias: Final Result Day-time

Radiation Bias: Final Result Day-time + 2.5% RH

Radiation Uncertainties

CONCLUSIONS GRUAN and IASI are consistent!! There are many critical issues: Adequate collocation: scale lengths and times of WV are extremely small Full closure achievable if full GRUAN uncertainty matrix (including correlation terms between levels) and collocation uncertainty are available Water Vapour saturation function: Hyland and Wexler needed If we want collocation unceratinty ~ 0 we need dual sondes GRUAN processing needed!! Mostly for humidity bias correction Proper cloud detection is critical GRUAN processing seems to have a dry bias for daytime