Development and validation of RP- HPLC method for determination of ticagrelor in pharmaceutical dosage formulation

Similar documents
International Journal of Pharmacy and Pharmaceutical Sciences Vol 2, Issue 1, 2010

Development and validation a RP-HPLC method: Application for the quantitative determination of quetiapine fumarate from marketed bulk tablets

Available online Research Article

International Journal of Innovative Pharmaceutical Sciences and Research

Development And Validation Of Rp-Hplc Method For Determination Of Velpatasvir In Bulk

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD TO DETERMINE CINITAPRIDE HYDROGEN TARTARATE IN BULK AND PHARMACEUTICAL FORMULATION

J Pharm Sci Bioscientific Res (4): ISSN NO

Novus International Journal of Analytical Innovations 2012, Vol. 1, No. 3

RP-HPLC Method Development and Validation of Dapagliflozin in Bulk and Tablet formulation

Development of Validated Analytical Method of Mefenamic Acid in an Emulgel (Topical Formulation)

Impact factor: 3.958/ICV: 4.10 ISSN:

A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS

RP-HPLC method for simultaneous estimation of amoxicillin and carbocisteine in dosage forms

Simultaneous estimation and validation of bromhexine and cephalexin in bulk and pharmaceutical dosage form by RP-HPLC method

Research Article. Figure 1. Chemical structure of doxofylline. Indonesian J. Pharm. Vol. 24 No. 1 : ISSN-p :

Development And Validation Of Stability Indicating RP-HPLC Method For Estimation Of Ledipasvir And Sofosbuvir

Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article. Estimation of zaleplon by a new RP-HPLC method

Analytical Method Development and Validation of Lafutidine in Tablet dosage form by RP-HPLC

Scholars Research Library

Development and Validation of Stability Indicating RP-HPLC Method for the Determination of Anagrelide HCl in Pharmaceutical Formulation

Development and validation of second order derivative methods for quantitative estimation of clopidogrel in bulk and pharmaceutical dosage form

Development and Validation of Stability Indicating Assay Method of Etodolac by using UV-Visible Spectrophotometer

Volume 6, Issue 2, January February 2011; Article-015

SIMPLE AND SENSITIVE VALIDATED REVERSE PHASE HPLC-UV METHOD FOR THE DETERMINATION OF LYMECYCLINE IN PHARMACEUTICAL DOSAGE FORMS

Department of Quality Assurance, Luqman College of Pharmacy, GULBARGA (K.S.) INDIA ABSTRACT

A Reverse Phase Liquid Chromatography Analysis of Citicoline Sodium in Pharmaceutical Dosage Form using Internal Standard Method

Stability indicating RP-HPLC method for determination of azilsartan medoxomil in bulk and its dosage form

Development and validation of RP-HPLC method for determination of marker in polyherbal marketed Kankasava formulations

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

SIMULTANEOUS RP HPLC DETERMINATION OF CAMYLOFIN DIHYDROCHLORIDE AND PARACETAMOL IN PHARMACEUTICAL PREPARATIONS.

STABILITY INDICATING RP HPLC METHOD FOR ANALYSIS OF DORZOLAMIDE HCl IN THE BULK DRUG AND IT S PHARMACEUTICAL DOSAGE FORM

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF GABAPENTIN IN PURE AND PHARMACEUTICAL FORMULATIONS

Research Article METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF ELBASVIR AND GRAZOPREVIR BY RP-HPLC

Pharmacophore 2011, Vol. 2 (4), ISSN Pharmacophore. (An International Research Journal)

Stability Indicating RP-HPLC Method for Determination of Valsartan in Pure and Pharmaceutical Formulation

A novel analytical method development and validation for the estimation of simvastatin in bulk and pharmaceutical dosage forms by RP-HPLC

Validated RP-HPLC Method for Estimation of Cefprozil in Tablet Dosage Form

Method Development and Validation Of Prasugrel Tablets By RP- HPLC

Journal of Drug Delivery and Therapeutics

Development and Validation of Sensitive RP-HPLC Method for the Estimation of Glibenclamide in Pure and Tablet Dosage Forms

Journal of Chemical and Pharmaceutical Research

International Journal of Pharma and Bio Sciences V1(1)2010. HPLC method for analysis of Lercanidipine Hydrochloride in Tablets

RP-HPLC Estimation of Trospium Chloride in Tablet Dosage Forms

Reverse Phase High Performance Liquid Chromatography method for determination of Lercanidipine hydrochloride in bulk and tablet dosage form

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

Development and validation of rapid HPLC method for determination of Aripiprazole in bulk drug and pharmaceutical formulation

INTERNATIONAL JOURNAL OF RESEARCH IN PHARMACY AND LIFE SCIENCES

Validated First Order Derivative Spectroscopic Method for the determination of Stavudine in Bulk and Pharmaceutical Dosage Forms

Journal of Pharmaceutical and Biomedical Analysis Letters. Analysis Letters

International Journal of Research and Reviews in Pharmacy and Applied science.

Development and Validation of RP-HPLC Method for the Estimation of Repaglinide in Bulk Drug and Pharmaceutical Formulation

AN IMPROVED ASSAY METHOD FOR THE ESTIMATION OF TICAGRELOR HYDROCHLORIDE BY REVERSE PHASE LIQUID CHROMATOGRAPHY

Method Development and Validation for the Estimation of Darunavir in Rat Plasma by RP-HPLC

Development and validation of UV- spectrophotometric method for the estimation of dabigatran etexilate mesylate (dem)

Isocraticc Reverse Phase HPLC Method-Determination and Validation of Cilostazol

Development and validation of RP-LC method for lisinopril dihydrate in bulk and its pharmaceutical formulations

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

A Simple, Novel Validated Stability Indicating RP-HPLC method for estimation of Duloxetine HCl in Capsule Pharmaceutical Formulation

Available online at Scholars Research Library

Research Article Spectrophotometric Estimation of Didanosine in Bulk Drug and its Formulation

Impact factor: 3.958/ICV: 4.10 ISSN:

B. Anupama et al. IRJP 2 (1)

SIMULTANEOUS ESTIMATION OF CILOSTAZOL AND ASPIRIN IN SYNTHETIC MIXTURE USING HPTLC METHOD

Received: ; Accepted:

Development and validation of stability indicating reverse phase high performance liquid chromatography method for Timolol Maleate

Chapter 4: Verification of compendial methods

Scholars Research Library. Rapid and sensitive RP-HPLC analytical method development and validation of Pioglitazone hydrochloride

ANALYTICAL METHOD DEVELOPMENT AND VALIDATION OF STABILITY- INDICATING ASSAY METHOD OF TICAGRELOR TABLETS BY USING RP-HPLC

Int. J. Pharm. Sci. Rev. Res., 30(2), January February 2015; Article No. 09, Pages: 63-68

Liquid Chromatography and Spectroscopic Method for Estimation of Sulphadoxine in Marketed Formulation

Simultaneous Estimation of Metolazone and Spironolactone in Combined Tablet Dosage Form BY UV Spectroscopy.

International Journal of Research in Pharmaceutical and Nano Sciences Journal homepage:

Journal of Chemical and Pharmaceutical Research

Validated RP-HPLC Method for the Quantitation of Benfotiamine in Bulk and Tablet Dosage Form

STABILITY INDICATING METHOD OF RELATED IMPURITIES IN VENLAFAXINE HYDROCHLORIDE SUSTAINED RELEASE TABLETS

KEYWORDS: Acetaminophen, Doxylamine succinate, Dextromethorphan hydrobromide.

Analytical method development and validation of carvedilol in bulk and tablet dosage form by using uv spectroscopic method as per ich guidelines

Journal of Advanced Scientific Research DEVELOPMENT AND VALIDATION OF STABILITY-INDICATING RP-HPLC METHOD FOR ESTIMATION OF DABIGATRAN ETEXILATE

Determination of Fexofenadine Hydrochloride in Pharmaceutical Dosage Form By Reverse Phase High Performance Liquid Chromatography Method

Simultaneous Estimation Of Montelukast Sodium And Desloratadine By RP-HPLC In Their Marketed Formulation

Research Article. *Corresponding author S.Ushasri

DEVELOPMENT AND VALIDATION OF A HPLC METHOD FOR IN-VIVO STUDY OF DICLOFENAC POTASSIUM

Pelagia Research Library

*Author for Correspondence

PHARMA SCIENCE MONITOR

Dissolution study and method validation of alprazolam by high performance liquid chromatography method in pharmaceutical dosage form

INTERNATIONAL JOURNAL OF UNIVERSAL PHARMACY AND BIO SCIENCES

Pelagia Research Library

A Novel Stability Indicating Chromatographic Method Development And Validation For The Quantification of Tofacitinib In Pure And Its Dosage Form

ISSN: ; CODEN ECJHAO E-Journal of Chemistry , 9(1), 35-42

Chapter-4 EXPERIMENTAL WORK BY RP-HPLC

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

International Journal of Research in Pharmaceutical and Nano Sciences Journal homepage:

ABSTRACT. KEYWORDS: Capecitabine, UV spectrophotometry, ICH guidelines.

International Journal of PharmTech Research CODEN (USA): IJPRIF, ISSN: , ISSN(Online): Vol.9, No.7, pp , 2016

Pelagia Research Library

Research Article Available online at

Radhakrishnan K. et al. / International Journal of Pharmacy & Therapeutics, 3(1), 2012, e- ISSN Print ISSN

International Journal of Pharma Research and Health Sciences. Available online at

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Transcription:

Available online at www.scholarsresearchlibrary.com Scholars Research Library Der Pharmacia Lettre, 2016, 8 (9):206-212 (http://scholarsresearchlibrary.com/archive.html) ISSN 0975-5071 USA CODEN: DPLEB4 Development and validation of RP- HPLC method for determination of ticagrelor in pharmaceutical dosage formulation Eena Joshy, Anu Babu, Delma D cruz and Aneesh T. P.* Amrita School of Pharmacy, Amrita Vishwa Vidyapeetham University, AIMS Health Sciences Campus, Kochi, Kerala, India ABSTRACT The quantitative determination of Ticagrelor in pharmaceutical dosage forms was developed by using a simple accurate precise and cost effective method. The separation was achieved by isocratic method using phenomenex C18 column on a Shimadzu binary gradient liquid chromatographic system equipped with LC-20AD solvent delivery system, SPD-20A photo diode array detector and rheodyne injector with 20 µl loop volume. The mobile phase developed for the estimation of the drug in dosage form and in human plasma contains a mixture of acetonitrile and methanol in the ratio of 70:30% v/v at a flow rate of 1 ml/min at a detection wavelength 254 nm. Retention time of Ticagrelor in pharmaceutical formulation was found to be 3.793 min with a run time of 7 min. The drug showed linearity in the range of 10-100 µg/ml with a correlation coefficient (r 2 ) 0.9967.The results were found to be within the acceptance of ICH, USP guidelines. The described method was validated with respect to the system suitability parameters, linearity, precision and accuracy. Each solution was injected in triplicate, and %RSD was measured. The validation results obtained in the study shows that the proposed method can be easily and conveniently adopted for routine analysis of ticagrelor in pharmaceutical formulation. Key words: Ticgrelor, RP-HPLC, Method Development, Validation INTRODUCTION Analytical method development and validation used to distinguish the primary drug components from the impurities. Analytical methods are validated in order to demonstrate that method is suitable for intended purpose [1]. Analytical method will provide information on drug uniformity, drug release, evaluation of drug characteristics, potency, impurities etc. during the drug development and manufacturing. Analytical studies concentrate on spectrophotometric analysis and HPLC. Reverse chromatography is widely used in HPLC. Method development requires which instrument is used and why it s so. Choice of column, mobile phase, detectors, should be considered during the HPLC method development [2].The use of analytical methods during the drug development and manufacturing provide information on, Potency which can relate directly to the requirement of a known dose, Impurities which can relate to the safety profile of drug and evaluation of key drug characteristics such as drug release, drug uniformity, properties which can compromise bioavailability. Ticagrelor belongs to an oral antiplatelet agent, which inhibits the platelet activation and aggregation which is mediated by the P2Y12 ADP receptor. It blocks adenosine diphosphate (ADP) receptors of subtypep2y12 in contrast to other antiplatelet drugs, ticagrelor has a binding site different from ADP, making it an allosteric antagonist and the blockage is reversible[3]. Chemically it is 1S,2S,3R,5S)-3-[7-[(1R,2S)-2-(3,4-Difluorophenyl) cyclopropylamino]-5-(propylthio)-3h-[1,2,3] 206

triazolo[4,5-d]pyrimidin-3-yl]-5-(2-hydroxyethoxy)cyclopentane-1,2-diol (fig. 1). Ticagrelor is used to prevent signal transduction and platelet activation which inhibits platelet aggregation and thrombus formation in atherosclerotic disease. Ticagrelor is a nucleoside analogue, the cyclopentane ring is similar to the sugar ribose, and the nitrogen ring aromatic system resembles the nucleobase purine giving the adenosine molecule [4-5]. The results describes the method is simple, precise and accurate for the estimation of ticagrelor in pharmaceutical dosage form. The method was validated as per ICH guidelines. Figure.1: Structure of Ticagrelor MATERIALS AND METHODS Chemicals and reagents: The Active pharmaceutical ingredient was obtained from Swapnaroop drugs and Pharmaceuticals, Maharashtra, India. The pharmaceutical formulation was purchased from local market which contains Ticagrelor 90 mg. All the chemicals and reagents used were of Analytical or HPLC grade. Optimization of Chromatograhic conditions The separation was performed by using Phenomenex C18 (250 4.6 mm, 5 µm) column on a Shimadzu binary gradient liquid chromatographic system equipped with LC-20AD solvent delivery system, SPD-20A photo diode array detector and rheodyne injector with 20 µl loop volume. Analysis was carried out by isocratic method with a mobile phase consist of a mixture of acetonitrile and methanol in the ratio of 70% v/v in pump A and 30% v/v in pump B. It was found to be the most suitable mobile phase for ideal chromatographic separation of Ticagrelor. Mobile phase was pumped through the column at a flow rate of 1.0 ml/min with a run time of 7 min at a detection wavelength of 254 nm. The column was equilibrated by pumping the mobile phase through the column for at least 30 min prior to the injection of the drug solution. Figure.2: Chromatogram of Ticagrelor 10 µg/ml 207

Preparation of stock solution 10 mg of Ticagrelor was accurately weighed and 1000 µg/ml concentration of Ticagrelor was prepared as standard stock solution, using methanol as solvent. From the standard stock solution different concentrations were prepared ranging 10-100 µg/ml using mobile phase. 20 µl of each was injected in HPLC & chromatogram was taken. Chromatogram of standard is shown in (fig.2) Calibration curve Calibration curve was plotted against peak area and concentration which obeys Beer s law. Linearity was obtained by analysis of serially diluted sample in the range of 10-100 µg/ml. Calibration graph is shown in (fig.3). Figure.3. Calibration curve of Ticagrelor Validation of the method Validation parameters are done based on the ICH guidelines by evaluating linearity precision, accuracy etc [6]. Table.1: Linearity results of Ticagrelor Concentration (µg/ml) Area 10 1010823 20 1932626 30 2696877 40 3355496 50 4050929 60 4628695 70 5448596 80 6109169 90 6827269 100 7591809 Linearity 10-100µg/ml concentrations were prepared by serial dilution in different 10ml standard volumetric flask. Linearity of ticagrelor ranges from 10-100 µg/ml. Evaluation were done using U.V detector at 254 nm. The plotted calibration revealed good linear relation with concentration and area. The regression equation was found to be y = 73210x+307886 and correlation coefficient was found to be 0.9967. According to Beer s law the correlation 208

coefficient for linearity is 0.9999. Since the result is approximately close to the true value. The method is indicated as high significance [7-8]. The linearity results were shown in (Table.1). Precision Precision is related to repeatability and reproducibility. It is measurement of same results obtained from unchanged conditions with homogeneous sample. Repeatability was determined as intraday and reproducibility as interday precision, in accordance with ICH recommendations [9]. For intraday precision, evaluation was carried out by injecting standard solution at various time intervals and %RSD of ticagrelor was found to be 0.06% shown in (Table 2) where, inter-day precision was carried out in consecutive days with %RSD of 0.02% and 0.01% shown in (Table 3). The %RSD can be reach upto 2%. Since the results, less than 1% values, were found to be satisfactory, which indicates method is precise. Table 2: Intraday precision studies Days 1 ST DAY Standard Concentration n=3 Morning afternoon 40 3355496 3355587 3354251 3354362 3351794 3351694 MEAN 3353847 3353881 STD DEV 28577.6 28517.4 % RSD 0.06% 0.06% Table 3: Interday precision studies Standard Concentration n=3 Day 1 Day 2 50 4227541 4227274 4228652 4228176 4226663 4227285 MEAN 4227618.6 4227578.3 STD DEV 996.77 517.623 % RSD 0.02% 0.01% Accuracy In order to evaluate accuracy analytical recovery experiments are carried to study the interference of formulation additives, by standard addition of 50, 80 and 100% level in triplicates. Results were obtained by percentage recovery and relative standard deviation. The percentage recovery of Ticagrelor were found to be in the range of 99.6-99.75% and the mean recovery of ticagrelor was found to be 99.68%, shown in (Table 4) which shows very low interference from excipients, indicates the method is accurate. Table 4: Recovery studies Recovery Level Concentration Added (µg/ml) Concentration Found (µg/ml) % Recovery 50 40 39.9 99.75% 80 60 59.32 99.6% 100 80 79.8 99.7% Mean Recovery 99.68% Limit of Detection LOD was determined by standard deviation method and also from the slope of the calibration plot by using formula 3.3 σ/s. It was observed to be 0.971 µg/ml. Since the observed concentration was very low the method is sufficiently sensitive. Limit of Quantification LOD was determined by standard deviation method and also from the slope of the calibration plot by using formula 10 σ/s. It was observed to be 2.94 µg/ml. As the amount of analyte was found to be less, we can estimate the drug at very low concentration. 209

System suitability parameters In HPLC method the system suitability parameters were determined and analyzed for retention time, Number of theoretical plates, Tailing factor, Asymmetric factor, Calibration range and compared with standard values which shown in (Table 5).The retention time of Ticagrelor was 3.793 min.so the method is cost effective as it utilizes very less quantity of mobile phase. The theoretical plates were 2556.31. Since higher number of theoretical plates improves the efficiency of column, elution will be faster and tailing factor was 1.1 which shows the column is highly efficient [10]. Table 5: System suitability parameters Parameters Results Retention time 3.793 Tailing factor 1.2 Theoretical plates 2556.31 Calibration range 10-100 Asymmetric factor 1.5 Robustness Robustness shows that the results are unaffected by slight but deliberate variations in analytical method [11-12].It provides an indication about variability of the method during normal laboratory conditions like flow rate, mobile phase ratio, and wavelength shows in (Table 6). It was observed that an only slight variation in the chromatogram shows that the HPLC- method development is robust. Table 6: Robustness Parameters Condition Retention time Tailing factor 0.8 3.808 1.5 Flow rate 1 3.793 1.2 1.2 3.768 1.5 Mean(n=3) 3.789 1.4 70:30 3.793 1.2 Mobile Phase 80:20 3.810 1.25 90:10 3.820 1.5 Mean(n=3) 3.807 1.31 254 3.793 1.2 Detection Wavelength 230 3.748 1.25 240 3.771 1.5 Mean(n=3) 3.770 1.5 Quantification of Ticagrelor in dosage form Accurately weighed 10 mg equivalent of Ticagrelor from the dosage form and made 1000 µg/ml of Ticagrelor as stock solution using methanol as solvent. From above solution 20, 30, 40, 50 µg/ml concentrations were prepared using mobile phase and 20 µl of each was injected in HPLC & chromatogram was taken for quantifying the drug in dosage form. Chromatogram of sample was shown in (fig 4). The quantification of the drug is done using linear regression equation method and direct comparison method. Using linear regression method, Linear equation is y = 73210x + 307886 By substituting peak area of sample in y can obtain concentration of the sample The quantified drug concentration in 20, 30, 40, 50 µg/ml were found to be 19.8, 29.6, 39.8, and 48.4 µg/ml respectively which is shown in (Table 7). Direct comparison method Is done by using formula, 210

The quantified drug concentration in 20, 30, 40, 50 µg/ml were found to be 19.5, 28.6, 39.5, and 48.5 µg/ml respectively which is shown in (Table 8). Table 7. Quantification of Ticagrelor in dosage form by linear regression method Concentration (µg/ml) Sample of standard Drug Concentration Using (µg/ml) (%) 20 1751444 1932626 19.8 99% 30 2476877 2696877 29.6 98.6% 40 3221794 3355496 39.8 96% 50 3851426 4050929 48.4 96.8% Mean % 97.6% Table 8. Quantification of Ticagrelor in dosage form by Direct comparison method Concentration (µg/ml) of sample of standard Drug Concentration Using (µg/ml) (%) 20 1751444 1932626 19.5 97.5% 30 2476877 2696877 28.6 95.3% 40 3221794 3355496 39.5 98.75% 50 3851426 4050929 48.5 97% Mean % 97.1% Figure.4: Chromatogram of sample in dosage form 20 µg/ml CONCLUSION The developed and validated RP-HPLC method was found to be simple, precise, accurate and sensitive for the estimation of Ticagrelor in Pharmaceutical formulation. Validation of results according to ICH and USP carried out high accuracy and good precision. The RSD for all the parameters are found to be less than one, which indicates the validity of method is suitably fine. The mobile phase used in dosage form contains a mixture of acetonitrile and methanol in the ratio of 70% v/v in pump A and 30% v/v in pump B at a flow rate of 1 ml/min. The detector wavelength was found to be 254 nm in U.V spectroscopy. Retention time of Ticagrelor in pharmaceutical dosage form was found to be 3.793 min with a run time of 7 min. The drug shows linearity in the range of 10-100 µg/ml with a correlation coefficient of 0.9967. Hence, this method can be easily and conveniently adopted for the quality control analysis of Ticagrelor in Pharmaceutical formulation. REFERENCES [1] R.Singh, J. Pharm. Edu. Res., 2013, 4(1),26-33. [2] B.Prathapa, Dey. Akalanka, G.H. Srinivasa, P.Johnson & P.Arthanariswaran, I.J.N.T.P.S., 2013, 3(1), 15-23. 211

[3] D. Goel, Int. J. Appl. Basic. Med. Res., 2013, 3(1), 19-21. [4] RaeAnne and Benjamin Chavez, Pharmacy and Therapeutics., 2012, 37(10), 562-68. [5] R.Teng, S.Oliver, M.A.Hayes, K.Butler., Drug Metab. Dispos., 2010, 38(9), 1514-21. [6] ICH Harmonised Triparite Guidelines. Validation of Text and methodology Q2(R) 2005. In International conference on harmonisation of technical requirements for registration of pharmaceuticals for human use., 1996, 4. [7] A. Mrunal Ambasana, P.Naval Kapuriya, J. Nilkanth Faldu and D. Karthik Ladva, Der. Pharmacia. Lettr., 2014, 6(4), 237-40. [8] Rao. Lakshmana and L. Kalyani, Int. J. Pharm., 2013, 3(3), 634-42. [9] S.Savita, R.Janhavi, Asi. J. Pharm. Clin. Res., 2014, 7(1), 137-40. [10] P.L. Pingale, P.V. Nandasana, Int.J. Drug. Dev.Res., 2012, 4, 247-52. [11]H.K. Pannu, M.P. Mahajan, S.D. Sawant, Der. Pharma. Chemica., 2012, 4, 996-1002. [12]B. Dimple, M.Vinodh, M.Vinayak, Mal. J. Anal. Sci., 2013,17, 387-93. 212