TKI CU01 V-1.0_EN Cu separation from irradiated targets 01/12/10

Similar documents
1.1. This is a method for the separation and measurement of 228 Ra in water via its beta emitting 228 Ac daughter.

(CATION EXCHANGE AND LN RESIN, WITH VACUUM BOX SYSTEM)

SAFETY NOTE: Before beginning this procedure, read all of the Material Safety Data Sheets for the chemicals listed in Section 5 of this procedure.

NICKEL-63/59 IN WATER

URANIUM IN SOIL. Analytical Procedure (2 GRAM SAMPLE) 1. SCOPE

Method NumberUSTUR 150

enable measurement. This method separates these isotopes effectively.

THORIUM, PLUTONIUM, AND URANIUM IN WATER

TECHNETIUM-99 IN WATER

Toxicology Extraction Procedure for Base Drugs Using United Chemical Technologies Clean Screen Extraction Columns

Pu and Np-237 in seawater samples Version /03/14. Summary

Contact Person(s) : Anna Berne APPLICATION

Chapter 9. Volumetric Analysis

Uranium from water sample

Chemical Reactions of Copper and Percent Recovery

ANALYTICAL TASK EXPERIMENTAL PROCEDURE

Eichrom Technologies, Inc. Analytical Procedures Rev. 1.5 February 10, 2005 Page 1 of 9

TECHNETIUM-99 IN WATER

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

Modified Adams Assay for Phenolics in Wine

Method for estimation of iodine in urine

FerroZine Method 1 Method to 100 µg/l Fe (10-cm cell) Reagent Solution. Instrument Adapter Sample cell DR 6000 LZV

Web:

Dirks, C. 1, Happel, S. 2, Jungclas, H. 1

Diquat 1,1 -ethylene-2,2 -bipyridium dibromide salt Paraquat 1,1 -dimethyl-4,4 -bipyridium dichloride salt Initial Preparation

TECHNETIUM-99 IN SOIL

Synthesis of Benzoic Acid

[Unless otherwise stated all tolerances are ±5%] SAMPLES

Care and Use Manual for Supelco Multi-Layer Silica Gel Column and Dual-Layer Carbon Reversible Column

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

EXPERIMENT 20. Solutions INTRODUCTION

Synthesis and Analysis of a Coordination Compound

AgraQuant Plus Pistachio Sandwich ELISA

1. Preliminary qualitative analysis of unknown substances (liquid or solid).

The problems as we saw them were;

Advanced Unit 7: Chemistry Practical Examination (SET A) Candidates must have: Scientific calculator Ruler

PART II: ANALYSIS OF IRON COORDINATION COMPOUND

STUDYING CHEMICAL REACTIONS BY TITRATION ANALYSIS

AMERICIUM, NEPTUNIUM, PLUTONIUM, THORIUM, CURIUM, URANIUM, AND STRONTIUM IN WATER

Part II. Cu(OH)2(s) CuO(s)

GRIGNARD REACTION Synthesis of Benzoic Acid

Read the lab thoroughly. Answer the pre-lab questions that appear at the end of this lab exercise.

Functional Genomics Research Stream. Lecture: February 17, 2009 Masses, Volumes, Solutions & Dilutions

Preparing Extension Products for Electrophoresis

For Research Use Only

CHEMISTRY Organic Chemistry Laboratory II Spring 2019 Lab #2: Grignard Reaction: Preparation of Triphenylmethanol

Automation of the radiochemical procedures for the sequential separation of radionuclides

Ascorbic Acid Titration of Vitamin C Tablets

Cl 2(g) + NaCl + H 2 O. light. 2Cl. Once formed, the chlorine radical can react with the heptane as shown below: + Cl

CHEM Practice to be done before the lab. Experiment 9 Introduction to Volumetric Techniques II. Objectives

Experiment 3: Acid/base Extraction and Separation of Acidic and Neutral Substances

NITRITE, Low Range (0 to mg/l NO 2- -N)

Operating Instructions for Ammonium ISE Specifications

Brooklyn College Department of Chemistry

Salicylate Method Method HR (2 to 47 mg/l NH 3 N) TNTplus 832

Supernatant: The liquid layer lying above the solid layer after a precipitation reaction occurs.

Chromatography: Thin-Layer Chromatography (TLC) & Column Chromatography

EXPERIMENT 2. Gravimetric Analysis of a Soluble Chloride

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

Determination of Orthophosphate Ion

DR/4000 PROCEDURE MERCURY. Phase 1: Sample Digestion must be done in a fume hood! Toxic gases may be produced.

Soil Sample Preparation Protocol (Modified from Faegri and Iversen 1 ; Moore and Webb 2 protocols)

EXPERIMENT. Estimate the strength of given sodium carbonate solution by titrating it against HCl solution using methyl orange as indicator.

Chemistry 151 Last Updated Dec Lab 8: Precipitation Reactions and Limiting Reagents

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

OHP assay Mod. 6/15/10 LMD Dourte from Ansorge, Erickson, Boxburger Hydroxyproline Assay for Collagens

Unit 5 Part 2 Acids, Bases and Salts Titrations, Indicators and the ph Scale UNIT 5 ACIDS, BASES AND SALTS

Detection limit: grain, feed 500 ppb; milk 50 ppb; cream, cheese 5 ppb

Zearalenone Plate Kit PN 53018B

Chemistry Calibration of a Pipet and Acid Titration

IV. EQUIPMENT a. Horiba LA 950 main unit b. Dry sample unit that has a silencer behind it c. Cell slide unit that holds

Supernatant: The liquid layer lying above the solid layer after a precipitation reaction occurs.

CORESTA Recommended Method No. 86

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA

The Molecular Weight of Carbon Dioxide

Technology that counts

Expt 10: Friedel-Crafts Alkylation of p-xylene

CHAPTER 15 PREPARATION 0? REAGENTS. Since the level of iron in serum is so low, contamination is the most important cause of inaccuracy.

Acid-Base Extraction

Mercury, total-in-sediment, atomic absorption spectrophotometry, nameless, direct

Apply the ideal gas law (PV = nrt) to experimentally determine the number of moles of carbon dioxide gas generated

Experiment 2: THE DENSITY OF A SOLID UNKNOWN AND CALIBRATION WITH DATASTUDIO SOFTWARE

[Unless otherwise stated all tolerances are ±5%] SAMPLES

Expt 9: The Aldol Condensation

Determination of Orthophosphate Ion

DPD Test N Tube Method *

Experiment 10. Acid Base Titration

You must bring 1-2 empty pop cans to lab this week.

Name: Date: AP Chemistry. Titrations - Volumetric Analysis. Steps for Solving Titration Problems

SPECIFICATION & TEST PROCEDURE SODIUM SALICYLATE Technical. Molecular weight : Reference : In-house

Introduction to Work in Laboratory

Practical 1 Procedure Iron by Titrimetry

The Thermodynamics of the Solubility of Borax

Manual Solid Phase Peptide Synthesis Protocol (modified 12/14/16)

Please use only the valid version of the package insert provided with the kit. This kit is intended for Research Use Only.

TITRATION OF AN ACID WITH A BASE

Nitrofuran (SEM) ELISA test Kit

Name: Section: Score: /10 PRE LABORATORY ASSIGNMENT EXPERIMENT 7

Experimental Procedure. Lab 406

EnAlgae SOP sheet: Silicate - SFA. 1. Purpose This procedure is to analyse seawater and freshwater for silicate, SiO2.

Transcription:

1 Apparatus 1.1 Analytical balance- 0.0001 g sensitivity 1.2 Beaker (10 ml, 50 ml) 1.3 Watch glass 1.4 Vortex mixer 1.5 20 ml PE vials 1.6 Pipettes 1.7 Fume hood 1.8 Hotplate 1.9 Empty 2 ml columns incl. appropriate frits 1.10 Vacuum box or vacuum bottle with column adaptor 1.11 Vacuum box accessories: white and yellow tips, blue caps 1.12 Vacuum pump Alternatively a positive pressure set-up (e.g. peristaltic pump based) might be used 2 Reagents 2.1 All references to water should be understood to mean deionized water (18 MΩ). 2.2 Hydrochloric acid (HCl), 37%, p.a. 2.3 0.01M HCl (ph >2) - Add ca. 900 ml of water in to a 1000 ml volumetric flask. Add 0.8 ml conc. hydrochloric acid. Complete with water. Adjust ph to 2.2 (+/- 0.1) with deionized water and or dilute HCl. This solution can be used for 1 year after its preparation. 2.4 8M HCl - Add ca. 300 ml of water in to a 1000 ml volumetric flask. Add 666 ml concentrated hydrochloric acid. Complete with water. This solution can be used for 1 year after its preparation. 2.5 Bulk CU resin Page 1 / 5

3 Procedure 3.1 Column preparation: 3.1.1 Weigh 0.35g of the resin into a 20 ml PE vial 3.1.2 Add 5 ml of 0.01M HCl (ph >2) solution and allow resin to soak for at least 30 min, preferably while shaking 3.1.3 Allow 2 ml standard column and frits to soak in water for at least 30 min 3.1.4 Place appropriately sized containers in vacuum box, place lid on top of box. Into each of the holes of the box tightly fit yellow tips, into these tightly fit white tips. 3.1.5 Empty soaked columns. Fix appropriate number of empty 2 ml standard column onto white tips, close remaining white tips with blue caps. 3.1.6 Transfer soaked resin into empty column and turn vacuum on. Allow liquid to pass the column, then turn vacuum off. 3.1.7 Add 4 ml of 0.01M HCl (ph >2) solution onto the column and turn vacuum on. Allow liquid to pass the column, turn vacuum off. Repeat until column is tightly packed and free of bubbles and channels (max. 5 times). Place frit on top of resin. Note 1: The columns can run dry, but shouldn t stand dry for prolonged time (> 10 min). In case a column is not used immediately add another 4 ml of 0.01M HCl (ph >2) on top of the column, turn on vacuum and allow approx 2 ml of the solution to pass. Turn off vacuum and close lower and upper end of column (e.g. with ParaFilm). The so prepared column might be stored for several days (preferably at room temperature and in the dark). 3.1.8 Preconditioning of the column. A freshly prepared column can be considered as preconditioned. In case a column has been stored for prolonged time it is preferable to precondition the column anew. To do so place column on prepared vacuum box, turn on vacuum and allow solution contained in the column to pass the column. Add 4 ml of fresh 0.01M HCl (ph >2) and allow to pass. Note 2: The column rinsing can be done at a flow rate of up to 3 ml/min 3.2 Loading solution preparation: 3.2.1 Dissolve irradiated target. Note 3: For Ni targets you might use the following method: Place irradiated Ni foil into an appropriate container and place container on hotplate. Add 1 ml 6M HCl per 100 mg of Ni foil and cover container with watch glass. Heat solution while stirring. Add H 2O 2 drop wise until target is dissolved (approx. 0.7 ml H 2O 2 (30%) per 100 mg Ni foil, depending on thickness of the foil). 3.2.2 Evaporate obtained solution to dryness. Rinse beaker and watch glass with water and re-evaporate. Dissolve residue in 1 ml of 0.01M HCl (ph >2) solution. Page 2 / 5

3.3 CU separation: 3.3.1 Place appropriately sized and labeled container below the columns. 3.3.2 Transfer solution onto prepared CU resin column. 3.3.3 Rinse container with 1 ml 0.01M HCl (ph >2) solution, transfer solution onto the same CU resin column. 3.3.4 Turn on vacuum, adjust flow rate to 1 ml/min and allow solution to pass column. 3.3.5 Add 5 ml of 0.01M HCl (ph >2) solution onto the column and adjust flow rate to 6 ml/min. Allow solution to pass. Note 4: The container contains approx. 100% of the target material at this stage and might be removed for Ni recovery and replaced by a fresh container. 3.3.6 Add 3 ml of 0.01M HCl (ph >2) solution onto the column and allow solution to pass at a flow rate of 6 ml/min. Turn off vacuum. 3.3.7 Place fresh, labeled, appropriately sized container below column. 3.3.8 To elute the Cu-64 add 1 1.5 ml of 8M HCl onto the column. Turn on vacuum, adjust flow rate to 1mL/min. Allow solution to pass. Note 5: In some cases the Cu eluate might be too acidic for direct use, in this case it might need to be converted to lower acid concentration or neutral media this can either be done via an evaporation/redissolution step or via an anion exchange step as described in 3.4. 3.4 Optional: Cu eluate conversion via anion exchange 3.4.1 Per Cu eluate to be converted weigh 400 mg anion exchange resin into a 20 ml PE vial. 3.4.2 Add 5 ml of 0.1M HCl and allow resin to soak min. 30 min. 3.4.3 For each Cu eluate to be converted place one empty 2 ml column in an appropriate rack. Allow column to soak in water for at least 30 min. 3.4.4 Transfer soaked resin into emptied soaked column and allow the resin to settle. Place container below column and break lower tip. Allow solution to pass column. 3.4.5 Subsequently rinse column with 2mL 2M HCl, then 2 ml 4M and at last 2 ml 8M HCl. The column is conditioned and ready for use. Place fresh container below the column. 3.4.6 Carefully transfer the Cu eluate on top of the AIX column without perturbing the resin bed. Allow solution to pass through the resin at gravitational flow. Note 6: The separation might also be performed using vacuum or positive pressure set-ups, flow rates should be kept below 1 ml/min anyhow. 3.4.7 Rinse container that contained the Cu eluate with 0.6 ml 8M HCl, transfer rinsing solution onto column. Allow solution to pass through the resin at gravitational flow. Page 3 / 5

3.4.8 Rinse resin with max. 0.2 ml deionised water. Allow solution to pass through the resin at gravitational flow. Place fresh, labeled, appropriately sized container below column. 3.4.9 Elute Cu using 0.6 0.8 ml of deionised water or saline solution. 3.5 Synopsis of the separations 3.5.1 Cu separation on CU resin Page 4 / 5

3.5.2 Cu eluate conversion on AIX resin 4 References (1) C. Dirks, B. Scholten, S. Happel, A. Zulauf, A. Bombard, H. Jungclas: Characterisation of a Cu selective resin and its application to the production of 64Cu. Accepted manuscript, J Radioanal. Nucl. Chem, DOI 10.1007/s10967-010-0744-9, (2010) Eichrom Referenz: T-DC110. (2) C. Dirks, S. Happel: Characterization of a Cu selective resin and its application to the production of Cu-64. Presentation at the TrisKem International users group meeting, 14/09/2010, Chester (UK); available online: http://www.triskem-international.com/iso_album/ugm_chester_10_dirks_happel_cu_resin.pdf Page 5 / 5