GPC/MS. Analysis of PET

Similar documents
Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE

Optimizing GPC Separations

Gel Permeation Chromatography Basics and Beyond eseminar March 13, Jean Lane Technical and Applications Support LSCA, Columns and Supplies

Practical Steps in GPC Method Development

GPC / SEC Theory and Understanding

Characterization of polyphenylene sulphide using the Agilent PL-GPC 220 High Temperature GPC System with triple detection

Lecture 4 : Gel Permeation or Size Exclusion Chromatography

An Introductions to Advanced GPC Solutions

GPC/SEC standards. Product guide

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

LC-MS Based Metabolomics

GPC/SEC standards. Product guide

GPC/SEC An essential tool for polymer analysis

Polymer analysis by GPC-SEC. Technical Note. Introduction

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

Maximizing Performance Through GPC Column Selection

Speeding up 2D chromatography (HPLCxSEC) at it s limits. ..fast, faster ups broken...

Chapter 14. Molar Mass Distribution.

Advanced GPC. GPC On Tour, Barcelona, 28 th February The use of Advanced Detectors in GPC

Comprehensive Polymer Analysis Strategies

Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. H i

Gel Permeation Chromatography (GPC) or Size Exclusion Chromatography (SEC)

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Clearing the Confusion: GPC, SEC, GFC What, When, Why, and How?

Progress toward reliable NC molecular mass distribution by GPC

Analysis of Star Polymers Using the Agilent 1260 Infinity Multi-Detector GPC/SEC System

Selecting Detectors for Compounds with No Optical Absorbance

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

Organic GPC/SEC columns. Product guide

Supporting information

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

Determination of Polymer Modifier in Asphalt

Olumide Adebolu. Chromatographic Fidelity and Matrix /Analyte Solubility in Complex Polymer Systems using HPLC-MALD/I TOF MS

Comparison of Polymer Separation by Size Exclusion Chromatography and Asymmetric Flow Field Flow Fractionation

M M e M M H M M H. Ion Sources

Supplementary Material (ESI) for Chemical Communications This journal is (c) The Royal Society of Chemistry 2008

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

Biochemistry. Biochemical Techniques HPLC

Differentiation of polymer branching and composition using the Mark Houwink plot

TANDEM MASS SPECTROSCOPY

Macromolecular Chemistry

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

Selecting an LC/MS Interface Becky Wittrig, Ph.D.

LC Technical Information

Optimization of PLA/PLGA molecular weight and structure to suit final application requirements

Analysis of Polar Metabolites using Mass Spectrometry

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Molecular Weight Distribution of Living Chains in Polystyrene Pre-pared by Atom Transfer Radical Polymerization

Chemically recyclable alternating copolymers with low polydispersity from

Supporting Information. segments

Open Column Chromatography, GC, TLC, and HPLC

Chapter 27: Gas Chromatography

How Molecular Weight and Branching of Polymers Influences Laser Sintering Techniques

Use of High Speed/High Resolution Size-Based Chromatographic Separation of Polymeric Mixtures with Offline Infrared Detection

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Tips & Tricks GPC/SEC: Inter-Detector Delay

Applicability of GPC, GC-MS and 13 C NMR techniques and DFRC method in comparative structural studies of Lignin

Waters GPC User Guide and Tutorial for Using the GPC in the Reynolds Research Group 2 nd Edition: April 2012

HPLC Praktikum Skript

Mass Spectrometry in MCAL

Marine bio-inspired underwater contact adhesion

Lecture 15: Introduction to mass spectrometry-i

Red Color CPL Emission of Chiral 1,2-DACH-based Polymers via. Chiral Transfer of the Conjugated Chain Backbone Structure

Molecular Mass Spectrometry

GPC/SEC Start-up Kit

LC and LC/MS Column Selection Flow Chart

Supporting Information

GPC - Gel Permeation Chromatography. aka Size Exclusion Chromatography- SEC

Introduction of Hitachi Chromaster 5610 MS Detector for High Performance Liquid Chromatograph

CASE STUDY. Degradation of Polyethylene by FTIR and High Temperature GPC

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

AGILENT AQUEOUS AND POLAR GPC/SEC COLUMNS

Varian 385-LC. ELSD for Low Molecular Weight Compounds

HPLC. High Performance Liquid Chromatography (HPLC) Harris Chapter 25

Luminescence transitions. Fluorescence spectroscopy

770-9P. Sensitivity and Selectivity - A Case Study of LC/MS Enantioselective Resolution of Bupivacaine Using Vancomycin as a Chiral Stationary Phase

Introduction. Chapter 1. Learning Objectives

Zwitterionic Polymerization: A Kinetic Strategy for the Controlled Synthesis of Cyclic Polylactide

MODERN HPLC FOR PRACTICING SCIENTISTS

Chemistry Gas Chromatography: Separation of Volatile Organics

Ring-Opening Polymerization of N-Carboxyanhydrides Initiated by a Hydroxyl Group

Spectroscopy and Chromatography

Supplementary Information. Mapping the Transmission Function of Single-Molecule Junctions

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

One-pot polymer brush synthesis via simultaneous isocyanate coupling chemistry and grafting from RAFT polymerization

CALIBRATING GPC COLUMNS

High Pressure/Performance Liquid Chromatography (HPLC)

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

COURSE MATERIAL: Unit 3 (Part 1) Polymer Science LT8501 (Click the link Detail to download)

Evaporative Light Scattering Detector (ELSD)

Analysis of polyolefins by GPC/SEC

Supporting Information

Aqueous and polar GPC/SEC columns. Product guide

Training Courses. Chromatography training from the Crawford Scientific experts

Agilent 385-ELSD Evaporative Light Scattering Detector

Dilution(*) Chromatography

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

Transcription:

Recent Developments in:- GPC/MS High Temperature ELSD Analysis of PET Graham Cleaver BWM

Overview Coupling GPC with APCI Mass Spectrometry To identify the number of oligomers in a low molecular weight polystyrene sample. Accurately identify additives without the need for complete resolution High Temperature Evaporative Light Scattering Detection (HTELSD) Refractive index detection at high temperatures in solvents such as TCB is not without challenges. HT-ELSD has undergone further developments to offer a viable alternative. Analysing PET in Chloroform A novel piece of work showing how the polymer can be dissolved in HFIP and then chromatographed in Chloroform. 2

GPC/MS Oligomers & Additives BWM

Introduction Miniaturization in GPC Improved Resolution Lower Flow Rates Reduced Solvent Consumption 3 x 10µmMixed B columns, 300x7.5mm Conventional RID THF, flow rate = 1 ml/min 2 x PolyPore columns, 250 x 2.1mm µri detector THF, flow rate = 50 µl/min 4

Atmospheric Pressure Ionization (API-ES) The possibility to use a very low solvent flow rate make 2.1mm diameter columns ideal for MS The possibility to use volatile solvents and isocratic conditions Usually, for GPC the electrospray (ES) process is used, mainly because of the possibility to have multiple ions on the higher molecular weight polymers 5

Atmospheric Pressure Chemical Ionization (APCI) However the API-ES interface creates multiple ions and complex MS spectra, which can prove difficult to interpret directly without deconvolution. APCI produces, under soft ionization conditions, only the molecular ion. Although the quadrupole MS with APCI is limited to m < 2000 (because z = 1), this is enough to study the oligomers and the majority of the additives 6

Theoretical and Measured Distribution of Anionic Polystyrene Oligomers (n=7, C60 H66) Chloroform is compatible with both GPC and MS Under APCI conditions [M+Cl]- ions are produced (SCAN mode) Excellent correlation between theoretical and measured distribution EasiVial PS580 PS anionic; styrene = 104 [PS+ Bu + H + Cl] = n*104 + 57 + 1 + 35 Eg. n=8 821 7

Chromatograms Corresponding to each Oligomer It is possible to create specific single ion monitoring methods for each targeted molecule in a mixture (SIM Mode) Even without a complete separation, GPC-MS can monitor each oligomer The method is similar to extracting peaks when using DAD 8

Linear Calibration Curve Each oligomer can be used to create a column calibration Separation mechanism is true GPC Resipore columns 250 x 2.1mm 9

Identifying and Quantifying Polymer Additives OH HO O O O CH 2 O CH 2 C CH 2 O O CH 2 O O OH OH HO O O Even in the case of low resolution separations it is possible to identify and quantify additives 10

High Temperature ELSD Polyolefin Characterization BWM

Evaporative Light Scattering (ELSD) Nebulisation Liquid flow from the column is nebulised using nitrogen or air to give a plume of fine droplets containing the analyte in solution Evaporation The liquid droplets pass into a heated zone where the solvent is removed to leave the dried analyte particles Detection The analyte particle is subsequently irradiated with light; and the amount of light scattered by the particle is measured 12

High Temperature Evaporative Light Scattering (HT-ELSD) ELSD is independent of any physical or chemical properties of the polymer Sensitivity At least a factor of 10 higher than RID Accurately measures the concentration (independent of dn/dc) Minimal equilibration time, very stable baselines No solvent peaks, positive sample response Sensitivity Linearity 13

How does it compare to its predecessor? (ELS1000) PL-ELS 1000 HT-ELSD Mw = 9,930 ELS 1000 data up-scaled by a factor of 10 Mw = 2,950,000 Mw = 223,500 Mw = 605 14

Summary Of HT-ELSD Superior sensitivity as compared to a DRI, making it preferable for UHMWPE samples that require very low concentration for dissolution and analysis Stable baseline, the removal of solvent peaks, and suitability for high temperature gradient chromatography Improved linearity and accuracy in the determination of molecular weights, due to a new nebulizer design, which reduces operating temperatures 15

Triple Detection PET Analysis BWM

A novel approach to characterizing PET Polyesters are used extensively for fibers and packaging worldwide production of PET is estimated at 40 million tons. The mechanical and chemical resistance properties of PET make it difficult to dissolve. GPC Analysis M-cresol at elevated temperatures to reduce eluent viscosity HFIP, lower temperatures, still high viscosity, handle with caution, very expensive 17

Dissolve the PET in HFIP, Analyze Using Chloroform In this application we overcome these issues by initially dissolving the polymer in HFIP, but then running the analysis in Chloroform. When dissolving a polymer in one solvent, but then analyzing in a different solvent, interaction with the packing material is a potential issue. 600ul of HFIP was added to 43mg of polyester sample in a 10ml flask. Dissolution time of 3 hours, chloroform then added Multi detector signal for the Polyester sample 18

Molecular Weight Using Triple Detection MH plot for the polyester sample Molecular weight distribution of the polyester sample The linear MH plot indicates that there is no change in structure across the molecular weight distribution of the PET. In addition, the slope of 0.75 suggests that the polymer is in a good solvent and has a random coil conformation. The molecular weight (Mw) calculated by the triple detection analysis for this sample compares very well with the expected value of 45,000 The method of dissolution and analysis of the PET sample by firstly dissolving in HFIP followed by analysis in Chloroform with triple detection produces reliable molecular weight information 19

Acknowledgements Ansuman Mahato Application specialist Manesar COE Laboratory India 20

Any Comments Questions? BWM