Premier Heritage 3-15X50 User Manual

Similar documents
EPOCSELFIR LACITCATiX5T TECHNICAL MANUAL

5-25x56 PMII PSR With Double Turn

RT-6 Riflescopes. User Guide

P4Xi TACTICAL Riflescope TECHNICAL MANUAL

2-7x32. Instruction manual

Table of Contents. Specifications 1 Adjustments 2 Using the Reticle 8 Maintenance 16 Troubleshooting 18 SS Warranty 19

USER MANUAL REFLEX SIGHT. Ultra Shot Z Series. English / Francais / Español / Deutsch

NcSTAR SHOOTER II SERIES SCOPE

The Vortex. Dual Use: Shooting Tactical / Hunting US Patent 8,166,696 US Patent 7,937,879. Elevation. Adjustment Dial.

5-25x56 PMII PSR Illuminated with Double Turn

LEAPERS, INC. RED/GREEN DOTS

30 mm Diameter Main Tube 1-4x24 Models

Dual Use: Shooting Tactical / Hunting US Patent 8,166,696 US Patent 7,937,879. Radius Bar. Reticle Focus. Elevation Adjustment Knob

HD Gen II 1 6x24 Riflescope. The Vortex Razor

Second Focal Plane MRAD

???? The Vortex Crossfire II Riflescopes

USER MANUAL REFLEX SIGHT. Ultra Shot Plus

The Vortex Razor HD Gen II-E 1 6x24 Riflescope

ULTRA SHOT PLUS - DARK EARTH REFLEX SIGHT SM26008DE

The Vortex Razor HD Gen II 1 6x24 Riflescope

Second Focal Plane MOA

30 mm Diameter Main Tube

Instruction Manual. Made in Japan

OWNER S MANUAL 4 16X X X44

1-6 x 24 Second Focal Plane MOA

C4 PLUS RIFLESCOPES User Guide

USER MANUAL. Core TX Riflescope Series

RIFLESCOPES User Guide

S5 SERIES Rifl escope Rifl

FIELD GUIDE FOR HORUS SCOPES

RIFLESCOPE RIFLESCOPE MANUAL

ZFK 4 X 25. Description and Utilization Instructions

Binocular Riflescope Instruction Manual M

Second Focal Plane Reticle

INTREPID x 50 Riflescope

USER MANUAL. Wolverine FSR and CSR Series SM26020 SM26020DE SM26020-LQD SM26021 SM26021DE SM26021-LQD

USER MANUAL. Wolverine FSR and CSR Series SM26020 SM26021 SM26020-LQD SM26020-LQD

RANGER 1-4 x 24 RIFLESCOPE

ROMEO ROMEO6 1x30mm FULL SIZE RED DOT SIGHT

User Manual for Blackhawk Riflescope

USER MANUAL. EZEKIEL 3-30x56. Riflescope. English / Francais / Español / Deutsch

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

4-14X44 FRONT FOCAL PLANE SCOPE WITH ARC-2 MOA RETICLE

The Vortex Golden Eagle Riflescopes

ABOUT SIGHTMARK. Sightmark - MAKE YOUR MARK

1-6X24 SECOND FOCAL PLANE SCOPE GEN III WITH PATENTED ACSS 7.62X39/300BO RETICLE

Please read entire manual before using your new optic. Fast Focus Eyepiece. Elevation Turret. MAG-Bar. Side Focus Dial (Select Models) Reticle Focus

Operating Manual 1.1-4x24 Zenith x24 Zenith

EE 1/3.5х14 U EE 1/3.5х14 U

1-8X24 SECOND FOCAL PLANE SCOPE WITH PATENTED ACSS.223/5.56, 5.45X39,.308 WIN RETICLE PA1-8X24SFP-ACSS-5.56

Binocular Riflescope Instruction Manual

USER MANUAL RIFLESCOPES. Triple Duty & Tactical Series. English / Francais / Español / Deutsch

Platinum Series. 6-30x56 Front Focal Plane Scope. with Patented ACSS.308/.223 HUD DMR Reticle. Advanced Combined Sighting System

Owner s Manual. 1 4x24 Riflescopes. Features Adjustments Mounting Maintenance Troubleshooting... 19

ELECTRO-OPTICS TANGO TANGO4 TACTICAL RIFLESCOPES OWNERS MANUAL

Dual Red or Green Electronic Dot Sight Instruction Manual

ULTRA SHOT R-SPEC REFLEX SIGHT SM26031

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

Platinum Series. Platinum Series. 6-30x56 Front Focal Plane Scope. with Patented ACSS.308/.223 HUD DMR Reticle

6XMag-1 Magnifier User manual

S7SERIES. Rifl escope

Trijicon ENHANCED ACCURACY IN LOW LIGHT OR NO LIGHT MODELS

TRIJICON ACCUPOINT ENHANCED ACCURACY IN LOW LIGHT OR NO LIGHT MODELS

USER MANUAL CORE SHOT A-SPEC FMS REFLEX SIGHT CORE SHOT A-SPEC LQD REFLEX SIGHT

Platinum Series. 6-30x56 Front Focal Plane Scope. with Patent Pending DEKA MIL Reticle. DEKA MIL reticle for unsurpassed accuracy at long range

ABOUT SIGHTMARK SIGHTMARK - MAKE YOUR MARK

RITON RT-S Mod 3 1-4x24 Illuminated Reticle Riflescope Manual

RITON RT-S Mod x56 Illuminated Reticle Riflescope Manual

PRECISION MAKES THE DIFFERENCE

BINOCULAR. 50 mm Tactical Binocular Manual HD R/T

MARINE BINOCULARS ZHUMELL 7X50 MARINE BINOCULARS WITH COMPASS AND RETICLE

ELECTRO-OPTICS TANGO TANGO6 TACTICAL RIFLESCOPES OWNERS MANUAL

1-6X24 SECOND FOCAL PLANE SCOPE GEN III WITH KISS RETICLE PA1-6X24SFP-KISS

ROMEO ROMEO4 1x20mm COMPACT RED DOT SIGHT

saxon Instruction Manual saxon Grandeur Brass Telescope High quality optics

MC ILLUMINATED USER MANUAL

PRIMARY ARMS 4-14X44 FRONT FOCAL PLANE SCOPE WITH PATENT PENDING ACSS HUD DMR 5.56 RETICLE PA4-14X44FFP-ACSS-HUD-DMR-5.56

Riflescope Instruction Manual

SpecterOS3.0 Optical Sight Operation Manual

Owner s Manual. 6 24x50 FFP Riflescopes 4 16x50 FFP Riflescopes. Features Adjustments Mounting Maintenance...

WARNING: Ensure weapon is not loaded prior to mounting riflescope.

1-4x24 with Uncapped Turrets

ACCUPOINT TRIJICON OVERVIEW MODELS

ASTRO-PHYSICS, INC. POLAR ALIGNMENT TELESCOPE

The 50mm Viper R/T binocular is equipped with the Vortex R/T Ranging reticle, designed to assist the user in calculating distances.

At Vortex Optics, the need for high-performance, precision optics is the driving force behind all that we do. Specifications Adjustments...

HS-T RIFLESCOP E. riflescope manual. Second Focal Plane MRAD

Owner s Manual. 6 24x50 Riflescopes 4 16x50 Riflescopes. Features Adjustments Mounting Maintenance Troubleshooting...

ASTRO-PHYSICS, INC. POLAR ALIGNMENT TELESCOPE (PASILL2)

CAUTION: BEFORE INSTALLATION, CONFIRM THAT THE CROSSBOW IS UNLOADED AND IS IN SAFE OPERATING CONDITION.

USER MANUAL. Core HX Riflescope Series SM13068HBR

CAUTION: BEFORE YOU BEGIN, ALWAYS MAKE SURE THE WEAPON IS UNLOADED AND SAFE TO HANDLE.

RR-Evolution-5.56/7.62 User Guide

Red and Green Dot Sight FF26002 USER MANUAL

3x30 BURST COMBAT SIGHT

RR-Evolution-3G User Guide

HS LR RIFLESCO PE HS LR RIFLESCOP E. riflescope manua L. Second Focal Plane Reticle

RIFLE SCOPE INSTRUCTION MANUAL

RED DOT SERIES ILLUMINATED SIGHTS INSTRUCTION MANUAL

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope

Transcription:

Premier Heritage 3-15X50 User Manual 175 Commonwealth Ct. Winchester, VA 22602 USA Phone: 540-868-2044 Email: info@premierreticles.com Website: www.premierreticles.com

Warning: Failure to follow the instructions outlined in this manual could result in the damage or destruction of the optic, its accessories, and/or bodily injury. Warning: Under no circumstances should you look through the optic directly at the sun or laser light devices. Doing so could result in severe and/or permanent eye damage. Mounting Hardware: Premier Reticles recommends that only high quality rings and bases made from steel or aluminum be used to mount the scope to a rifle and that all manufacturers instructions should be followed. With the articulating lens covers ring height should be no less than.97 to ensure no contact is made between the cover and the barrel. Table of Contents: Design/Layout.....3 Specifications.....4 Reticle Diagram... 4 Basic Operation: Dioption....5 Magnification... 5 Illumination.. 6 Changing the battery....6 Parallax.. 7 Elevation/Windage Operation. 7 Zeroing Elevation/Windage Knobs...8 Objective and Ocular Covers...9 Anti-Reflection Device..10 Maintaining the Scope: General Maintenance. 11 Operation/Maintenance in Special Climates..11 Maintenance Plan....12 Troubleshooting....13 Warranty/Repair Information. 13 2

Design And Layout: 3

Specifications: Length: 13.6 Height: 3.09 Width: 3.98 Weight: 38 oz. Tube Diameter: 34mm Objective Diameter: 50mm Magnification: 3X-15X Eye Relief: 3.54 Exit Pupil: 11.5mm 3.5mm Diopter Range: -3 to +2.5 Reticle: Illuminated Gen 2 Mil-dot Reticle Illumination Range: 11 Intensity Settings; 6-Hour Auto Shut Off Battery: CR2032 Click Value: 0.1 mrad Elevation Knob: 22 mrad Windage Knob: ±8 mrad Total Internal Travel: 117 MOA / 34 mrad Parallax Range: 50m Infinity Gen II Mil Dot 4

Basic Operation: Adjusting the Diopter: 1. Loosen the ocular lock ring by turning it counter clockwise. 2. Look through the ocular and adjust it in or out until the reticle is clearly in focus. 3. Now look away and look back through the ocular to ensure the reticle is still crisp and clear from edge to edge. 4. Once the ocular is set to proper dioption, tighten the ocular lock ring by turning it clockwise until it is snug. Adjusting Magnification: 1. Grasp the magnification ring and rotate to the desired level of magnification. LESS MAGNIFICATION MORE MAGNIFICATION Note: As the magnification increases or decreases the reticle will appear to become thicker or thinner, this is a result of the reticle being in the first focal plane. The reticle does not actually become any thicker or thinner but it maintains its subtension relative to the image so that ranging and trajectory compensation using the reticle can be done anywhere along the magnification range. 5

Illumination Function: 1. Grasp the outermost knob and pull away from the scope to enable the illumination function. 2. Rotate the knob clockwise and select one of the eleven intensity settings. The illumination will shut off between intensity settings however the barrel cannot be pushed back in. The illumination also has a six-hour auto shut off feature that helps preserve battery life. MORE INTENSITY 3. To turn off the illumination rotate the knob counter clockwise until the knob hits the stop and then push the illumination knob back in. LESS INTENSITY/OFF Changing the battery: 1. Use a coin or similar object to insert into the slot on the battery cover. 2. Rotate counter clockwise until the cover can be removed to expose the battery. 3. Remove the battery and replace with a fresh CR2032 coin cell battery. 4. Replace the battery cover and rotate clockwise until snug. 6

Adjusting Parallax: Parallax is the apparent movement of the reticle against the target caused by the reticle and target image not being on the same focal plane. When there is no parallax, the user can move their head slightly while looking through the scope and see no apparent movement of the reticle against the target. The Heritage has a large parallax knob on the left side that will allow the user to get parallax free from 50 meters to infinity. To remove parallax, look through the scope towards the target and move the head down slightly, looking for any movement of the reticle against the target. Follow the instructions below to get parallax free. IF THE RETICLE APPEARS TO GO DOWN, TURN THE KNOB CLOCKWISE. IF THE RETICLE APPEARS TO GO UP, TURN THE KNOB COUNTER-CLOCKWISE Operating The Elevation/Windage Knobs: The elevation and windage knobs are single turn knobs with 0.1 milliradian clicks and a more tactile clunk every ten clicks, there is also a zero stop.5 milliradian below zero. This is done so that the user can quickly make adjustments with confidence without having to look at the knobs, even in complete darkness if necessary. When zeroing the knobs the reticle can easily be used to calculate the correct necessary since both the adjustments and reticle are in milliradian. The Heritage is shipped optically and mechanically centered meaning that the user has equal elevation and windage travel to aid in zeroing the optic. UP DOWN LEFT RIGHT Note: The elevation and windage knobs may feel stiff when first received however the feeling of the clicks and clunks should improve with use. 7

Zeroing out the knobs: 1. Use a cartridge case or other object to lift the Lever-Lock toggle on top of the elevation and windage knobs. 2. Flip the toggle 180 until the toggle is upside down. 3. Grasp the knob and reset it to zero. While turning the knob it will still have audible clicks and clunks however there will be no change in zero. 4. Once the knob is reset to zero, flip the toggle back to the upright position. 8

5. Now, attempt to close the toggle. Firm steady pressure should be used to close the toggle correctly. If the toggle is not in the optimal position then the toggle will not close or it will require excessive pressure to close. If excessive pressure is necessary to close the toggle, lift it and turn counter clockwise 1/16 th of a turn, then retry. Too little pressure on the toggle can result in the toggle becoming loose while turning the knob, which can result in no correction being made despite audible clicks and clunks. The Articulating Objective and Ocular Covers: The Heritage is available with articulating lens covers that fold completely back and can be easily configured to open according to the user s preferences. 9

Removal of the Objective and Ocular Lens Covers: 1. Place the heel of the hand on the face of the cover and use the fingers to pry the edges of the cover over the ridge on the finish ring. 2. Once the edge of the cover is over the ridge in several places, it should easily come off exposing the ridge that goes around the finish ring. Installation of the Objective and Ocular Lens Covers: 1. Place the cover over the ridge on the finish ring. 2. Use the heel of the hand to press firmly against the cover until it snaps into place. 3. Position the cover as necessary. Installation of the Anti-Reflection Device: 1. Remove the objective cover per the instructions above. 2. Thread the ARD into the threads on the finish ring. 3. Turn the ARD clockwise until snug. Do not tighten beyond hand tight as too much force can cause the ARD to lock up and potentially damage the ARD when attempting to remove it. 4. While the ARD is in place the objective cover cannot be used, take measures to prevent its loss or damage. 10

Maintaining The Scope: The Heritage is designed to be a very durable optic built to withstand harsh use, however this does not mean it is completely maintenance free, follow the steps below to ensure your scope will stay in good working order. General Maintenance: Main Tube: 1. Inspect the main tube for dents, scrapes, and/or gouges that could affect the function of the scope. 2. Wipe the main tube down with a soft, lint-free cloth. Moving Parts: 1. Ensure the fit, form, and function of all moving parts by working them several times to look for any rough movement or lock up. 2. Inspect for broken or missing parts. 3. Use a soft bristle brush to remove dust and other debris from moving parts. Lenses: 1. Inspect lenses for scratches or nicks to the lens surface. 2. Use a soft bristle, optics-quality lens brush to remove dirt and large particles from the lens surface. 3. Use a lens pen or optics-quality lens cleaning solution in addition to quality lens paper to clean the lens surface by using a spiral motion beginning at the center of the lens and moving out towards the edge of the glass. 4. Remove any residue or streaks from the lens surface using the lens pen or a piece of lens paper. Flip Caps: 1. Inspect the objective and ocular covers for damaged or missing parts. 2. Remove the objective and ocular covers and clean with warm, soapy water. 3. Rinse with clean water and allow to air dry. Anti-Reflection Device: 1. Remove the ARD from the optic and inspect the honeycomb structure for grit, dirt, or other foreign matter. 2. Blow through the honeycomb to remove any grit, dirt, or other foreign matter present. 3. If necessary run plain water through the honeycomb to clear any debris. 4. Tap the housing lightly on a solid object to clear any excess water and blow through the honeycomb to dry. Operation and Maintenance in Special Climates: Cold Weather: 1. Protect the optic from extreme temperature changes when at all possible. If bringing the optic into warm room from a cold environment, place a scope cover over the optic and do not remove the cover until it has reached room temperature. 2. Condensation should be removed using a soft cloth and the optics should be dried using a cleaning cloth or lens pen. 3. At low temperatures the moving parts and knobs can become stiff and difficult to move. Rotate them repeatedly to loosen them up and turn more freely. If moving them repeatedly does not correct the problem use a piece of cloth to rub the parts to build friction and slowly warm the parts. Avoid warming the optical components quickly and with too much heat, doing so can cause damage. Do not breathe on the glass components to warm them up. 11

Arid Weather: 1. Protect the optic from dust and sand, this means all moving parts and glass components. Failure to do so can cause permanent damage to lens coatings and the possible failure of moving parts from the build up of sand and grit. 2. Keep rubber parts flexible by rubbing them with talcum powder. Humid Weather: 1. High humidity and salty environments will enhance corrosion. 2. Inspect the optic often for corrosion damage and service accordingly. Maintenance Plan: Item Component Inspection When? Before/After 1. Main Tube Damage, B/A Cleanliness 2. Lenses Damage, B/A Cleanliness 3. Lens Covers Damage, B/A Cleanliness 4. Battery Performance, B/A Leakage 5. Battery Cap Damage, B/A Function 6. Diopter, Damage, Fit, Form, and B/A Elevation/Windage Function Adjustment, Parallax, and Illumination Control 12

Troubleshooting Chart: Problem Cause Corrective Action Reticle will not illuminate. Weak/Dead Battery. Change CR2032 battery. Damaged illumination band. Return for repair. Reticle will not focus. Diopter not adjusted properly. Adjust diopter per instructions and secure lock ring. Spots on the reticle or in the Dirt or other material on the Return for repair field of view. reticle and/or internal lenses. Target will not focus. Parallax not adjusted properly. Adjust parallax per instructions. Loose internal lens. Magnification will not change. Power adjustment ring locked. Lever-Lock toggle will not Too much pressure on the open. toggle when closed. Return for repair. Return for repair. Lift the toggle carefully if possible to prevent damage and reset per the instructions. Elevation and/or windage will not track properly. Lenses fog internally and/or moisture on internal lenses. Lens covers will not open or close properly. Scope tube bent and/or otherwise damaged. Toggle damaged. Lever-Lock toggle not tightened properly and has become loose during knob operation. Damaged elevation or windage knob or damaged internal components. Failed o-ring seal. Covers are not seated properly. Damaged covers. Improper mounting. Dropped. Other hard impact. Return for repair. Tighten the Cam Lock toggle to the proper tension per the instructions. Return for repair. Return for repair. Seat the covers over the ridge per the instructions. Replace lens cover. Return for repair. Warranty/Repair: T he Premier Heritage is backed by a lifetime warranty. If there is a problem with your scope that requires repair or replacement of a component that goes beyond what is outlined in this manual contact us. DO NOT attempt to repair anything outside of what is outlined in this manual. Premier Reticles Ltd. 175 Commonwealth Court Winchester, VA 22602 P hone: 540-868-2044 Fax: 540-868-2045 Email: info@premierreticles.com Website: www.premierreticles.com 13

14