Generation of monodisperse aerosols through condensation nuclei control

Similar documents
Chapter 9 Generation of (Nano)Particles by Growth

Differential Mobility Particle Sizer (Aerosol measurements)

An Aerosol Generator for High Concentrations of µm Solid Particles of Practical Monodispersity

ENVR 116 Introduction to Aerosol Science December 17, 2001 FINAL EXAMINATION

Generation and Evaluation of Monodisperse Sodium Chloride and Oleic Acid Nanoparticles

High Temperature Condensation Particle Counter (HT- CPC)

9 Condensation. Learning Goals. After studying this chapter, students should be able to:

HETEROGENEOUS CONDENSATION FOR SUBMICRONIC PARTICLE ABATEMENT: EXPERIMENTS AND MODELLING

COPLEY S C I E N T I F I C. A multi-function aerosol system with aerosol generation, classification and monitoring capabilities for:

EVAPORATION YUSRON SUGIARTO

Sampling. Information is helpful in implementing control measures for reducing pollutant concentration to acceptable levels

Chapter 7 Precipitation Processes

MODULE 4.3 Atmospheric analysis of particulates

Sampling parameter effect on the particle size distribution during controlled dilution

ELECTROSTATIC CLASSIFIER MODEL 3082

M. Rogozina, M. Zhukovsky, A. Ekidin, M. Vasyanovich. Institute of Industrial Ecology, Ural Branch Russian Academy of Sciences

Lecture 1: Vapour Growth Techniques

Chapter 3 Matter and Energy

Aerosol Dynamics. Antti Lauri NetFAM Summer School Zelenogorsk, 9 July 2008

Chapter 5: Nanoparticle Production from Cathode Sputtering. in High-Pressure Microhollow Cathode and Arc Discharges

Chapter 1 INTRODUCTION AND BASIC CONCEPTS

Collision and Coalescence 3/3/2010. ATS 351 Lab 7 Precipitation. Droplet Growth by Collision and Coalescence. March 7, 2006

Clouds associated with cold and warm fronts. Whiteman (2000)

MEASURING NANOPARTICLE EXPOSURE

Precipitation. Size! Shape! Size distribution! Agglomeration!

USING THE ELECTRET FILTER TO REMOVE THE SUBMICRON AEROSOLS

Matter: Properties & Change

: HEAT TRANSFER & EVAPORATION COURSE CODE : 4072 COURSE CATEGORY : B PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 70 CREDIT : 5 TIME SCHEDULE

Which particle diagram represents molecules of only one compound in the gaseous phase?

Nanoparticle Exposure in the Workplace

Condensational Growth of Ultrafine Aerosol Particles in a New Particle Size Magnifier

Integration of Boiling Experiments in the Undergraduate Heat Transfer Laboratory

Particle counting efficiencies of new TSI condensation particle counters

Mobility-Based Particle Size Classification and Detection down to 2nm Theory to Practice

Aircraft Icing Icing Physics

Atomic Absorption Spectrophotometry. Presentation by, Mrs. Sangita J. Chandratre Department of Microbiology M. J. college, Jalgaon

4.1. Physics Module Form 4 Chapter 4 - Heat GCKL UNDERSTANDING THERMAL EQUILIBRIUM. What is thermal equilibrium?

GAW - WCCAP recommendation for aerosol inlets and sampling tubes

Introduction and Initial Field Data of a Novel, Portable Nanoparticle Sizing Instrument

QUT-Thermodenuder (TD)

Appendix: Laboratory Testing Methods

Standardisation of Particulate and Aerosol Measurements. Hanspeter Andres

Lab 4 Major Anions In Atmospheric Aerosol Particles

LABORATORY 5 AEROSOL AND CLOUD PARTICLE CHEMICAL COMPOSITION. by Dr. Randy Borys Desert Research Institute Reno, NV

Chapter 7 Solid Surface

(1) The packing group assignment for routes of administration other than inhalation of vapors shall be in accordance with the following table:

J. Schneider & Chr. Voigt - Physics and Chemistry of Aerosols and Ice Clouds

How can homogeneous and heterogeneous mixtures be. 1. classified? 2. separated?

The aerosol mass spectrometer flowtube apparatus

Traceability research activities in the field of airborne particle number/ mass concentration measurement Liu Junjie, Zhang Wenge, Song Xiaoping

Chasing Aerosol Particles Down to Nano Sizes

Particle Size Distribution Measurements with the Novel 1 nm-smps

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

Technical know-how in thermal analysis measurement

Gas Chromatography. Presented By Mr. Venkateswarlu Mpharm KTPC

CHAPTER 3: MATTER. Active Learning Questions: 1-6, 9, 13-14; End-of-Chapter Questions: 1-18, 20, 24-32, 38-42, 44, 49-52, 55-56, 61-64

Influence of temperature on the production and size distribution of fine particles released from beech wood samples

Improving the Nanoparticle Resolution of the ELPI

Topic 19b. Thermal Properties of Matter

The Characteristics of a Soln

Step 1. Step 2. g l = g v. dg = 0 We have shown that over a plane surface of water. g v g l = ρ v R v T ln e/e sat. this can be rewritten

MEASUREMENT OF ELECTRIC CHARGE OF AEROSOL PARTICLES GENERATED BY VARIOUS METHODS

Methods of pollution control and waste management - laboratory. Adsorptive removal of volatile organic compounds from gases streams

SCI-PS SOL Practice Questions - Physical Science 2 (Matter, Energy) Exam not valid for Paper Pencil Test Sessions

Water and Aqueous Systems

WEATHER MODIFICATION ARTIFICIAL RAIN MAKING AND CLOUD SEEDING. Research done in this field goes back to as far as the early 1940s when the US military

Heat Capacity of Water A) heat capacity amount of heat required to change a substance s temperature by exactly 1 C

Nanoparticle Trajectories In An Electrostatic Precipitator: Numerical Simulation And Experimental Validation

ABSTRACT INTRODUCTION

S.E. (Chemical) (Second Semester) EXAMINATION, 2011 HEAT TRANSFER (2008 PATTERN) Time : Three Hours Maximum Marks : 100

Methods of Separation. Vacuum Filtration. Distillation. The Physical Separation of Matter Chemistry 11 2/17/2014

Nanoparticle Synthesis and Assembly from Atomistic Simulation Studies

Heat and Mass Transfer Unit-1 Conduction

Pool Boiling Heat Transfer to Pure Liquids

Bell Ringer. What are the two types of mixtures? What is an element? What is a compound?

CHEMISTRY Ch. 14 Notes: Mixtures and Solutions NOTE: Vocabulary terms are in boldface and underlined. Supporting details are in italics.

Properties of Vapors

Particles Summary Sheet

Phase Transformations

Exam 2: Cloud Physics April 16, 2008 Physical Meteorology Questions 1-10 are worth 5 points each. Questions are worth 10 points each.

Performance Analyses of a Multiple Horizontal Tubes for Steam Condensation

A new versatile condensation particle counter for research and environmental monitoring

Particle Theory. Matter is anything that has volume and mass.

Sodium Chloride - Analytical Standard

Environmental control systems for defining the activity size distribution of radioactive aerosols - a case study

Precipitation. GEOG/ENST 2331 Lecture 12 Ahrens: Chapter 7

A New Volatility Tandem Differential Mobility Analyzer to Measure the Volatile Sulfuric Acid Aerosol Fraction

Product data sheet Palas Nanoparticle measurement system DEMC 2000

Chapter #6 Properties of Matter

Responses of Low Pressure Andersen Sampler for Collecting Substrates

SOP SMPS BaltimorePM supersite Version /29/01 Page 1 of 13 SMPS

Lesson 9: States of Matter

Effect of aging on cloud nucleating properties of atmospheric aerosols

Convective Mass Transfer

Unsteady Flow Of A Dust Particles Through Human Airways: Effects Of Uniform Magnet

Brian Sargent, Assistant Director, Designee 3/21/18. See Thread for Approval

Aerosol Basics: Definitions, size distributions, structure

Fundamentals of Particle Counting

PRINCIPLE OF ICP- AES

CHEM 254 EXPERIMENT 7. Phase Diagrams - Liquid Vapour Equilibrium for two component solutions

Transcription:

Air Pollution XV 505 Generation of monodisperse aerosols through condensation nuclei control H. M. Kadlimatti 1, S. Gangamma 2 & S. K. Varghese 3 1 Department of Mechanical Engineering, Basaveshwar Engineering College, Bagalkot, India 2 Department of Chemical Engineering, National Institute of Technology, Karnataka, Surathkal, India 3 Departmant of Civil Engineering, National Institute of Technology, Karnataka, Surathkal, India Abstract A device for the generation of monodisperse aerosols through condensation nuclei control has been designed and tested in the present study. A continuous flow, evaporation-condensation aerosol generator has been designed to produce monodisperse aerosols of low vapor pressure organic liquids, such as dioctyl phthalate (DOP), at flow rates over 2.5 lpm. Nebulised NaCl particles are passed through the particle number controller to reduce the number concentration close to 10 5 /cc to suppress homogeneous condensation. The condensation nuclei with nitrogen as a carrier gas are passed through a bubbler containing DOP, producing a nuclei vapor mixture. The mixture is condensed producing the aerosols of narrow size distribution. A heater section previous to the condenser section provides complete evaporation across the tube diameter, while the condenser walls in free convection create a low temperature gradient, both of which enhance aerosol monodispersity. The results show that controlling the nuclei number concentration as well as vapor source can produce aerosols with sufficient monodispersity. Keywords: condensation nuclei, evaporation, condensation, monodisperse aerosol. doi:10.2495/air070501

506 Air Pollution XV 1 Introduction An important element of aerosol technology is the production of test aerosols for calibrating instruments, conducting aerosol research, developing and testing air cleaning and air sampling equipment. Monodisperse aerosols are used to calibrate particle size measuring instruments and to determine the effect of particle size on sampling devices. A monodisperse aerosol is usually defined as an aerosol that has a geometric deviation of less than 1.2. In aerosol research, monodisperse test aerosols of known size, shape and density are highly desirable because most aerosol properties depend strongly on particle size, which is best controlled by using monodisperse aerosols. Tests made with a series of monodisperse aerosols, each having a different particle size, permit the evaluation of the effect of particle size on aerosol properties or the performance of an instrument. Test aerosols also used for various types of inhalation studies, such as studies of animal exposure to toxic substances, respiratory deposition in humans or animals and the administration of therapeutic aerosols [3]. Understanding the fundamental mechanisms of aerosol nucleation and growth has long been a central problem in aerosol science. Such understanding has important implications in characterizing and controlling fine particle emissions from combustion systems and in elucidating the dynamic processes governing the formation and growth of atmospheric aerosols. In simulating atmospheric aerosol dynamics, for example, it is desired to predict the rate of new particle formation as a function of the rate of generation of condensable vapor by gasphase chemical reactions. Predicting rates of new particle formation in the atmosphere requires consideration of the effect of both preexisting particles and newly formed growing particles on the vapor and cluster concentrations in the system Simultaneous homogeneous nucleation [5]. Sinclair and La Mer [8] first described the generation of aerosols by controlled condensation of vapour upon nuclei. Di-2-ethylhexyl sebacate (DEHS), an organic liquid with a low vapour pressure at room temperature acts as aerosol substance. Since DEHS is insoluble in water and known as non-toxic, its aerosols can be inhaled by a human being and used for deposition studies of particulate matter in the human respiratory tract Aerosols with particle sizes below 10 µm may be generated by condensation. A stream of nuclei is exposed to the vapour of a low-volatile liquid at an elevated temperature, and the controlled heterogeneous condensation of the vapour onto the nuclei results in the formation of the product aerosol [2]. For particle sizes down to 0.1 µm the use of aerosol generators of the La Mer- Sinclair type provides monodisperse aerosols. Other types of condensation aerosol generators were used by many authors to generate aerosols with particle sizes below 0.1 µm But most of this system--heated wire generator exploded wire generator high intensity arc generator plasma torch generate polydisperse or low concentrated quasimonodisperse aerosols with decreasing concentrations with time. The use of electrically heated tube furnaces to vapourize the aerosol material show the possibility of the generation of highly concentrated aerosols by means

Air Pollution XV 507 of homogeneous condensation. The particle sizes range down to 1 nm with long time stability but with size distributions with geometric standard deviations of σ g 2.5 i.e. polydisperse aerosols. Monodisperse aerosols are obtained after electrostatic classification. The high concentrations and the relative small size distributions of the primary condensation aerosols provide classified monodisperse aerosols with concentrations between 10 3 and 10 6 particles/cm 3 for particle diameters down to 2 nm [7]. For some applications, such as instrument calibration, a monodisperse aerosol is desired. There is however no precise definition of a monodisperse aerosol, i.e. how small a spread of particle sizes constitutes monodisperse. As most generated aerosols have a lognormal distribution, the geometric standard deviation, σ g, can be used as a measure of the monodispersity. That is, an aerosol, which has σ g less than about 1.22, could be assumed monodisperse. This arbitrary definition has no rigorous justification, but can be used as a rough indicator. Most so-called monodisperse aerosol generators can produce aerosols with σ g < 1.1 [6]. Milos et al, [4] have described a generator for producing monodisperse aerosols. The process involves atomizing the aerosol material (dioctyl phthalate was used) to form a polydisperse aerosol, which is rendered uniform by vaporization and condensation. The principle is similar to that used by Rapport and Weinstock and by Preining [4], but it has been found that by extracting a small percentage of the aerosol from the center of the stream from the condensing tube, a more monodisperse aerosol could be obtained. It is also found that dissolving the DOP in alcohol and could easily vary the size of the DOP aerosol by varying the solution concentration. Thus, with DOP concentration ranging from 0.001 to 100 per cent the size of the DOP aerosol could be varied from 0.036 µm to 1.3 µm dia. The device developed for the generation of monodisperse aerosols can be used for the study of air pollution effects at the laboratory level, as the effect of aerosol is size dependent. 2 Experimental setup The experimental setup used for the production of monodisperse aerosol by evaporation the condensation process is shown in figure 1. Using the nebuliser, a very dilute NaCl solution is sprayed from a nozzle to produce droplets. Upstream of the nebuliser, a diffusion dryer removes the water from the droplets to produce small crystals, depending on the original concentration of the solution. The particle number controller permits lowering of the concentration of the salt crystals from the original value, before the crystals are used as condensation nuclei in a heterogeneous condensation process. Since the concentration of the final aerosol is approximately same as concentration of the nuclei aerosol, the particle number controller can be used to control the aerosol concentration within the boundaries imposed by the heterogeneous condensation

508 Air Pollution XV process. The size of the aerosol particles is determined by the quantity of available vapor per nucleus. The number concentration of the nuclei is set by the flows in the particle number controller. The saturation of the gas, with vapor from the aerosol material, takes place in the bubbler. The nuclei aerosol bubble through the aerosol material at a constant temperature. Depending on temperature and vapor pressure, a certain saturation concentration of the vapor is achieved in the bubbler. The bypass around the saturator allows dilution of the saturated gas. This permits rapid adjustment of particle size by changing the ratio of bypass to total flow rate, rather than by waiting to heat or cool the saturator. The nuclei vapor mixture is re-heated, in the reheater section, to ensure that no condensation takes place upstream of the condensation chimney. In the condensation section, the vapor nuclei mixture is cooled down in a laminar flow and the resulting supersaturation causes the vapor to condense onto the nuclei. Control valve regulator Dryer Reheater gauge Nebuliser Particle remover NaCl solution Rotameter Bubbler Plenum Condenser N 2 cylinder Vacuum pump CNC/QCM Figure 1: 2.1 Aerosol measurement technique Experimental setup to generate monodisperse aerosols. Size segregated particulate mass was measured by cascade impactor with Quartz Crystal Microbalance (PC-2 QCM, California Measurements, INC, USA). The sampling flow rate is 1.5 lpm. The impactor has ten stages and segregates aerosol samples into ten size ranges between 25 and 0.05 µm. The manufacturer reported the cut sizes for the impactor for spherical particle of density 2 gcm -3. However, these cut diameters are different from the values reported in the calibration studies on the instrument [1]. In this study, the cut sizes of the impactor were adopted from Horton et al. [2]. The performances of the crystals were stable and satisfactory for the aerosols generated by aerosol generator. The aerosol concentrations observed on stages having cut sizes greater than 3.1 µm were very

Air Pollution XV 509 low and found to be statistically unreliable. Therefore, only the mass measured by stages having cut sizes less than 3.1 µm are used in our assessment. 3 Results and discussion The control over the number concentration of condensation nuclei close to 10 5 /cc is achieved with the help of particle remover. It is clear from the table 1 that, the diffusion battery is having very less collection efficiency compared to the particle remover which is having a collection efficiency of 71.42% (12 mg/l and 24 mg/l) with steel wool of diameter 0.15 mm and 91.42% (12 mg/l and 24 mg/l) with plastic fiber of diameter 0.14 mm. Since the particle remover with plastic fiber is having higher collection efficiency compared to the diffusion battery and the steel wool, particle remover with plastic fiber is used throughout the experiment The size distribution of the initial NaCl nuclei measured after passing through dryer is shown in figure 2. The initial NaCl nuclei have a MMD of 0.26 µm and probably number distribution peaks. This is ideal for generating particles in the sub micron range. The low vapor pressure liquid, DOP is then vaporized and condensed over the NaCl nuclei in the condenser section of the experimental setup. The size of the NaCl is increased due to the condensation process and is shown in the figure 3. The monodispersity is achieved by controlling the flow condition in the condenser tube. Table 1: Condensation nuclei number concentration. NaCl Concentration: 12 mg/litre (kg/cm 2 ) Flow rate (lpm) Value position 1.8 1.5 Closed Opened Number concentration per cc Diffusion Particle remover battery 1000 tubes Steel wool (1mm (0.15 mm diameter) diameter) Plastic fiber (0.14 mm diameter) 5 X 10 5 2 X 10 5 6 X 10 4 7 X 10 5 7 X 10 5 7 X 10 5 NaCl Concentration: 24 mg/litre (kg/cm 2 ) Flow rate (lpm) Value position 1.8 1.5 Closed Opened Number concentration per cc Particle remover Steel wool Plastic fiber (0.15 mm (0.14 mm diameter) diameter) 6 X 10 4 2 X 10 5 7 X 10 5 7 X 10 5

510 Air Pollution XV 20000 18000 16000 14000 Particle number 12000 10000 8000 6000 4000 2000 0 10 100 1000 Stokes diameter (nm) After dryer Before dryer Figure 2: Particle size before and after dryer. dm/mdlogdp (µm-1) 4 3.5 3 2.5 2 1.5 1 0.5 0 0.1 1 10 Aerodynamic diameter(µm) NaCl Case 1 Case 2 Figure 3: Mass size distributions of initial NaCl nuclei and aerosols after condensation of DOP vapour. For case 2 the temperature of the bubbler is 200 C and flow rate through the bubbler is 1.5 lpm, whereas for case 1 the temperature of the bubbler is 150 C and the bubbler flow is 1.5 lpm with the operating pressure 1.8 kg/cm 2. The

Air Pollution XV 511 increased bubbler temperature generated more vapor available for condensation with same number of nuclei, hence caused the increase in diameter compared to case 1. The both cases showed good monodispersity but the study is limited by the size resolution of the instrument used in the experiment. The results obtained are comparable with the results of Horton et al. [2]. References [1] Fairchild C.I. and Wheat L.D. (1984). Calibration and evaluation of a real time cascade impactor. Am.Ind.Hyg.Assoc.Journal, 45(4), pp.205-211. [2] Horton, K. D., Mitchell, J. P. and Nichols, A. L. Characterization of condensation type aerosol generator. J. Aerosol Sci. 22(3), pp. 347-363, 1991. [3] Hinds W.C. Aerosol Technology (Chapter 21), John Wiley. Inc, New York, pp. 428-446, 1999. [4] Milos T. B., Liu Y. H. Liu and Whitby K.T. Evaluation of the condensation aerosol generator for producing monodispersed aerosols. J. Aerosol Sci., 2, pp.39-46, 1971. [5] Pesthy A. J., Flagan R. C., and Seinfeld J. H. Theory of Aerosol Formation and growth in laminar flow. Journal of Colloid and Interface Science, 9(2), pp.525-545, 1983 [6] Ristovski Z.D., Morawska L. and Bofinger N.D. Investigation of a modified Sinclair-La Mer aerosol generator in the submicrometer range. J. Aerosol Sci., 29(7), pp.799-809, 1998. [7] Scheibel H.G. and Porstendorfer J. Generation of monodisperse Ag- and Nac1- aerosols with particle diameters between 2 and 300 nm. J. Aerosol Sci., 14(2), pp. 113-126, 1983. [8] Stahlhofen W. Gebhart J. Heyder J. and Roth C. Generation and properties of a condensation aerosol of di-2-ethylhexyl sebacate (DEHS). J. Aerosol Science. 6, pp.161-167, 1975