GA A26110 MEASUREMENTS OF THE INTERNAL MAGNETIC FIELD ON DIII-D USING INTENSITY AND SPACING OF THE MOTIONAL STARK MULTIPLET

Similar documents
GA A26744 MEASUREMENTS OF THE INTERNAL MAGNETIC FIELD USING THE B-STARK MOTIONAL STARK EFFECT DIAGNOSTIC ON DIII-D

GA A27290 CALCULATION OF IMPURITY POLOIDAL ROTATION FROM MEASURED POLOIDAL ASYMMETRIES IN THE TOROIDAL ROTATION OF A TOKAMAK PLASMA

GA A26732 DEUTERIUM VELOCITY AND TEMPERATURE MEASUREMENTS ON THE DIII-D TOKAMAK

GA A23797 UTILIZATION OF LIBEAM POLARIMETRY FOR EDGE CURRENT DETERMINATION ON DIII-D

Scaling of divertor heat flux profile widths in DIII-D

GA A26474 SYNERGY IN TWO-FREQUENCY FAST WAVE CYCLOTRON HARMONIC ABSORPTION IN DIII-D

GA A22722 CENTRAL THOMSON SCATTERING UPGRADE ON DIII D

GA A23713 RECENT ECCD EXPERIMENTAL STUDIES ON DIII D

Measurements of rotational transform due to noninductive toroidal current using motional Stark effect spectroscopy in the Large Helical Device

GA A27235 EULERIAN SIMULATIONS OF NEOCLASSICAL FLOWS AND TRANSPORT IN THE TOKAMAK PLASMA EDGE AND OUTER CORE

GA A25853 FAST ION REDISTRIBUTION AND IMPLICATIONS FOR THE HYBRID REGIME

GA A23736 EFFECTS OF CROSS-SECTION SHAPE ON L MODE AND H MODE ENERGY TRANSPORT

Overview of equilibrium reconstruction on DIII-D using new measurements from an expanded motional Stark effect diagnostic

GA A26057 DEMONSTRATION OF ITER OPERATIONAL SCENARIOS ON DIII-D

GA A23977 DETAILED MEASUREMENTS OF ECCD EFFICIENCY ON DIII D FOR COMPARISON WITH THEORY

GA A27857 IMPACT OF PLASMA RESPONSE ON RMP ELM SUPPRESSION IN DIII-D

RWM FEEDBACK STABILIZATION IN DIII D: EXPERIMENT-THEORY COMPARISONS AND IMPLICATIONS FOR ITER

GA A26123 PARTICLE, HEAT, AND SHEATH POWER TRANSMISSION FACTOR PROFILES DURING ELM SUPPRESSION EXPERIMENTS ON DIII-D

Plasma Response Control Using Advanced Feedback Techniques

UPGRADED CALIBRATIONS OF THE THOMSON SYSTEM AT DIII D

GA A26785 GIANT SAWTEETH IN DIII-D AND THE QUASI-INTERCHANGE MODE

GA A27806 TURBULENCE BEHAVIOR AND TRANSPORT RESPONSE APPROACHING BURNING PLASMA RELEVANT PARAMETERS

Validation of spectral MSE for Alcator C-Mod and for ITER

GA A26686 FAST ION EFFECTS DURING TEST BLANKET MODULE SIMULATION EXPERIMENTS IN DIII-D

IMPACT OF EDGE CURRENT DENSITY AND PRESSURE GRADIENT ON THE STABILITY OF DIII-D HIGH PERFORMANCE DISCHARGES

PLASMA MASS DENSITY, SPECIES MIX AND FLUCTUATION DIAGNOSTICS USING FAST ALFVEN WAVE

Simulation of Double-Null Divertor Plasmas with the UEDGE Code

GA A23114 DEPENDENCE OF HEAT AND PARTICLE TRANSPORT ON THE RATIO OF THE ION AND ELECTRON TEMPERATURES

GA A THERMAL ION ORBIT LOSS AND RADIAL ELECTRIC FIELD IN DIII-D by J.S. degrassie, J.A. BOEDO, B.A. GRIERSON, and R.J.

GA A25351 PHYSICS ADVANCES IN THE ITER HYBRID SCENARIO IN DIII-D

UNDERSTANDING TRANSPORT THROUGH DIMENSIONLESS PARAMETER SCALING EXPERIMENTS

TARGET PLATE CONDITIONS DURING STOCHASTIC BOUNDARY OPERATION ON DIII D

GA A26741 SCINTILLATOR-BASED DIAGNOSTIC FOR FAST ION LOSS MEASUREMENTS ON DIII-D

GA A24016 PHYSICS OF OFF-AXIS ELECTRON CYCLOTRON CURRENT DRIVE

PREDICTIVE MODELING OF PLASMA HALO EVOLUTION IN POST-THERMAL QUENCH DISRUPTING PLASMAS

SciDAC CENTER FOR SIMULATION OF WAVE-PLASMA INTERACTIONS

GA A24166 SUPER-INTENSE QUASI-NEUTRAL PROTON BEAMS INTERACTING WITH PLASMA: A NUMERICAL INVESTIGATION

Role of Flow Shear in Enhanced Core Confinement

GA A23698 ELECTRON CYCLOTRON WAVE EXPERIMENTS ON DIII D

GA A27805 EXPANDING THE PHYSICS BASIS OF THE BASELINE Q=10 SCENRAIO TOWARD ITER CONDITIONS

GA A22571 REDUCTION OF TOROIDAL ROTATION BY FAST WAVE POWER IN DIII D

STABILIZATION OF m=2/n=1 TEARING MODES BY ELECTRON CYCLOTRON CURRENT DRIVE IN THE DIII D TOKAMAK

GA A26119 MEASUREMENTS AND SIMULATIONS OF SCRAPE-OFF LAYER FLOWS IN THE DIII-D TOKAMAK

GA A27437 SCALING OF THE DIVERTOR HEAT FLUX WIDTH IN THE DIII-D TOKAMAK

CONTRIBUTIONS FROM THE NEUTRAL BEAMLINE IRON TO PLASMA NON-AXISYMMETRIC FIELDS

PROJECT PROGRESS REPORT (03/lfi?lfibr-~/15/1998):

Modeling of MHD Equilibria and Current Profile Evolution during the ERS Mode in TFTR

Multicusp Sources for Ion Beam Lithography Applications

Analysis of Shane Telescope Aberration and After Collimation

Two-Screen Method for Determining Electron Beam Energy and Deflection from Laser Wakefield Acceleration

Impurity Transport Studies of Intrinsic MO and Injected Ge in High Temperature ECRH Heated FTU Tokamak Plasmas

CORE TURBULENCE AND TRANSPORT REDUCTION IN DIII-D DISCHARGES WITH WEAK OR NEGATIVE MAGNETIC SHEAR

FAR SCRAPE-OFF LAYER AND NEAR WALL PLASMA STUDIES IN DIII D

GA A22689 SLOW LINER FUSION

GA A23198 HORIZONTAL THOMSON SCATTERING SYSTEMS FOR DIII D AND SSPX

GA A22863 PLASMA PRESSURE AND FLOWS DURING DIVERTOR DETACHMENT

HIGH SPATIAL AND TEMPORAL RESOLUTION VISIBLE SPECTROSCOPY OF THE PLASMA EDGE IN DIII-D

GA A22993 EFFECTS OF PLASMA SHAPE AND PROFILES ON EDGE STABILITY IN DIII D

Parametric Instabilities in Laser/Matter Interaction: From Noise Levels to Relativistic Regimes

GA A27444 PROBING RESISTIVE WALL MODE STABILITY USING OFF-AXIS NBI

Development of a High Intensity EBIT for Basic and Applied Science

GA A22677 THERMAL ANALYSIS AND TESTING FOR DIII D OHMIC HEATING COIL

Rotation Speed Differences of Impurity Species in the DIII-D Tokamak and Comparison with Neoclassical Theory

Scaling of divertor heat flux profile widths in DIII-D

Plasma Spectroscopy in ISTTOK

GA A25410 DISRUPTION CHARACTERIZATION AND DATABASE ACTIVITIES FOR ITER

N.H. BROOKS, R.C. ISLER,

GA A22877 A NEW DC MAGNETIC SENSOR

A Distributed Radiator, Heavy Ion Driven Inertial Confinement Fusion Target with Realistic, Multibeam Illumination Geometry

DML and Foil Measurements of ETA Beam Radius

Fission-Fusion Neutron Source

Start-up Noise in 3-D Self-AmpMed

GA A23411 COMPARISON OF LANGMUIR PROBE AND THOMSON SCATTERING MEASUREMENTS IN DIII D

GA A25658 PRECISION X-RAY OPTICAL DEPTH MEASUREMENTS IN ICF SHELLS

ONION-SKIN METHOD (OSM) ANALYSIS OF DIII D EDGE MEASUREMENTS

GA A27418 THE ROLE OF ZONAL FLOWS AND PREDATOR- PREY OSCILLATIONS IN THE FORMATION OF CORE AND EDGE TRANSPORT BARRIERS

proposed [6]. This scaling is found for single null divertor configurations with the VB

PROGRESS TOWARDS SUSTAINMENT OF INTERNAL TRANSPORT BARRIERS IN DIII-D

GA A23428 IMPROVEMENT OF CORE BARRIERS WITH ECH AND COUNTER-NBI IN DIII D

Applications of Pulse Shape Analysis to HPGe Gamma-Ray Detectors

in the pinch. This paper describes the computer modeling behind the shielding design of a

GA A27433 THE EPED PEDESTAL MODEL: EXTENSIONS, APPLICATION TO ELM-SUPPRESSED REGIMES, AND ITER PREDICTIONS

GA A23168 TOKAMAK REACTOR DESIGNS AS A FUNCTION OF ASPECT RATIO

Shock compression of precompressed deuterium

(4) How do you develop an optimal signal detection technique from the knowledge of

Controlling Backstreaming Ions from X-ray Converter Targets with Time Varying Final Focusing Solenoidal Lens and Beam Energy Variation

Alex Dombos Michigan State University Nuclear and Particle Physics

CSA$-9 k067s-~ STUDY OF THE RESISTIVE WALL MODE IN DIII-D GAMA22921 JULY 1998

HIFLUX: OBLATE FRCs, DOUBLE HELICES, SPHEROMAKS AND RFPs IN ONE SYSTEM

IN DIN-D ELECTRON CYCLOTRON CURRENT DRIVE

Using the X-FEL to understand X-ray Thomson scattering for partially ionized plasmas

Excitation of Alfvén eigenmodes with sub-alfvénic neutral beam ions in JET and DIII-D plasmas

Three-Dimensional Silicon Photonic Crystals

Modeling Laser and e-beam Generated Plasma-Plume Experiments Using LASNEX

GA A26866 REDUCED ELECTRON THERMAL TRANSPORT IN LOW COLLISIONALITY H-MODE PLASMAS IN DIII-D AND THE IMPORTANCE OF SMALL-SCALE TURBULENCE

A New Computational Method for non-lte, the Linear Response Matrix

Relating the L-H Power Threshold Scaling to Edge Turbulence Dynamics

GA A26099 CO2 LASER POLARIMETER FOR FARADAY ROTATION MEASUREMENTS IN THE DIII-D TOKAMAK

Initial Results from the Lick Observatory Laser Guide Star Adaptive Optics System

AC dipole based optics measurement and correction at RHIC

Transcription:

GA A26110 MEASUREMENTS OF THE INTERNAL MAGNETIC FIELD ON DIII-D USING INTENSITY AND SPACING OF THE MOTIONAL STARK MULTIPLET by N.A. PABLANT, K.H. BURRELL, C.T. HOLCOMB, R.J. GROEBNER, and D.H. KAPLAN MAY 2008

DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.

GA A26110 MEASUREMENTS OF THE INTERNAL MAGNETIC FIELD ON DIII-D USING INTENSITY AND SPACING OF THE MOTIONAL STARK MULTIPLET by N.A. PABLANT,* K.H. BURRELL, C.T. HOLCOMB, R.J. GROEBNER, and D.H. KAPLAN This is a preprint of a paper to be presented at the 17th Topical Conference on High Temperature Plasma Diagnostics, May 11-15, 2008, in Albuquerque, New Mexico, and to be published in the Proceedings. *University of California-San Diego, California Lawrence Livermore National Laboratory, Livermore, California Work supported by the U.S. Department of Energy under DE-FC02-04ER54698, DE-FG02-07ER54917 and DE-AC52-07ER27344 GENERAL ATOMICS PROJECT 30200 MAY 2008

ABSTRACT We describe a version of a motional Stark effect diagnostic based on the relative line intensities and spacing of Stark split D α emission from the neutral beams. This system, named B-Stark, has been recently installed on the DIII-D tokamak. To find the magnetic pitch angle, we use the ratio of the intensities of the π 3 and σ 1 lines. These lines originate from the same upper level and so are not dependent on the population levels. In future devices, such as ITER, this technique may have advantages over diagnostics based on motional Stark effect polarimetry (MSE). We have done an optimization of the viewing direction for the available ports on DIII-D to choose the installation location. With this placement, we have a near optimal viewing angle of 59.6 deg from vertical. All hardware has been installed for one chord, and we have been routinely taking data since January 2007. We fit the spectra using a simple Stark model in which the upper level populations of the D α transition are treated as free variables. The magnitude and direction of the magnetic field obtained using this diagnostic technique compare well with measurements from MSE polarimetry and EFIT. General Atomics Report GA A26110 iii

I. INTRODUCTION This paper describes a diagnostic, B-Stark, recently installed on the DIII-D tokamak at General Atomics. This system is a version of a motional Stark effect diagnostic and measures both the magnitude and direction of the internal magnetic field. These measurements are made using the relative line intensities and spacing of Stark split D α emission from the neutral beams. This differs from motional Stark effect polarimetry (MSE) which only measures the direction of the field and relies on the polarization properties of the D α light. The ability to measure the direction of the internal magnetic field has led to important advances in tokamak research. In particular, these measurements have allowed a better understanding of magnetic shear and the mechanisms behind improved confinement modes, such as H-Mode [1]. MSE polarimetry is now considered to be an essential diagnostic in tokamak and stellarator systems. Measurements of the magnitude from the magnetic field can provide additional information for magnetic equilibrium reconstruction codes such as EFIT [2]. These codes solve the Grad-Shafranov equation, and with several chords the f f term can be measured locally. This, in turn, can lead to better understanding of poloidal currents. The B-Stark diagnostic may have additional advantages over MSE polarimetry in devices with high densities and temperatures, such as ITER. Under these conditions coatings on plasma facing mirrors are expected. These coatings may interfere with MSE polarimetry by causing changes in the polarization direction of light incident on the mirror [3]. The B-Stark diagnostic is not sensitive to the polarization direction. It is, however, sensitive to polarization dependent transmission. There is a simple calibration procedure using a beam into gas shot that can be used to correct for this effect. Diagnostics to measure the direction of the magnetic field based on the Stark intensities have been developed and used on TEXTOR [4] and JET [5]. Both of these systems had nonoptimal viewing locations on the midplane, which required them to use additional information to make the measurement. In addition, both of these experiments measured the total π and σ intensities, requiring the assumption of statistical upper level populations. Measurements of B based on the Stark spacing have been made in JET [5][6] and in the MST reversed field pinch [7]. This new system installed at DIII-D has two main advantages over the previous diagnostics; it has a near optimal viewing direction, and DIII-D has an excellent MSE polarimetry system [8] with which the B-Stark measurements can be compared. A similar diagnostic system has been proposed for ITER [9]. General Atomics Report GA A26110 1

II. THEORY This diagnostic relies on the emission spectrum from the neutral heating beams on DIII- D. We are interested in the light from the D α ( n = 3 to n = 2 ) transition, around λ 0 = 6561.0 Å. Stark splitting of the energy levels occurs when the atom is exposed to an electric field. For the deuterium atoms injected into the plasma by the neutral beams, there are two sources of electric fields. There is a Lorentz electric field produced by the particle's motion across the magnetic field, and a radial electric field from the plasma. This electric field can be written as E = v b B+ E r. For our diagnostic, typical v b B fields will have a magnitude of ~ 4 10 6 V/m, while typical E r fields are around 5 10 4 V/m. We therefore ignore the E r field in our calculations. In certain high performance plasmas the E r field can be as large as 2 10 5 V/m [8], and a calculation including E r is needed. The effect of Zeeman splitting in calculating the spacing between the lines can be ignored, and a linear Stark effect is assumed [5]. For the linear Stark effect the spacing between the lines can be written as Δλ = λ 0 2 (3/2)(ea 0 /hc) E [9]. The lines are polarized parallel to the electric field for Δm = 0 ( π transitions), and polarized perpendicular to the field for Δm = ±1 ( σ transitions). The intensity of the emission is spatially anisotropic, and the ratio of π to σ light can be used to find the direction of the electric field. In general this requires the level populations of the n = 3 states to be known. Two sets of lines, π ± 3/σ ±1, originate from the same upper level removing the dependence on the level populations [9]. The intensity ratio of these lines is I π = 2sin2 Θ I σ 1+ cos 2 Θ AT f, (1) where Θ is the angle between the viewing direction and the electric field, A is the constant ratio of the transition probabilities, and T f the the π to σ transmission ratio for the optical system. The angle Θ can be related to the magnetic field through the Lorentz field vector and the viewing direction. The line intensity ratio in Eq. (1) can then be related to the magnetic field ratio B θ / B y. General Atomics Report GA A26110 3

2 AT f I π I σ 2 AT f + I π I σ = B l z + l θ y B y 1 + B θ B y 2 2. (2) Here the x ˆ direction is taken to be along the beam and the z ˆ direction is taken to be vertical. l y and l z are the y and z components of the unit viewing vector. B θ / B T can be related to B θ / B y though the known angle between the beam and the toroidal direction at the viewing location. B θ and B T are the poloidal and toroidal components of the magnetic field. 4 General Atomics Report GA A26110

III. EXPERIMENTAL SETUP For the B-Stark diagnostic, the viewing direction with respect to the neutral beam is important for several reasons. From Eq. (1) it can be seen that the sensitivity of the ratio to changes in Θ is maximized at 62.1 deg. This is the optimal viewing angle from the electric field, which in DIII-D is nearly vertical. For Doppler separation of the beam emission from the background D α emission, the viewing direction must be away from beam perpendicular. In order to achieve good radial resolution, the view must be tangent to the toroidal direction at the viewing location. To maximize signal levels, the viewing location must be outside of the magnetic axis where the neutral beam intensity is greatest. Lastly, a view crossing more than one beam allows better calibration and consistency testing. The final port chosen for the B-Stark installation allows views that cross two of the neutral beams, with angles of 57.8 deg and 64.9 deg, and have an angle of 59.9 deg from the vertical (Fig. 1). The radial resolution, calculated from the change in major radius over the neutral beam viewing volume, is 1 3 cm. Fig. 1. (Color On-line ONLY) B-Stark diagnostic geometry. Cross sections of the DIII-D vessel at the midplane and at a toroidal angle of 285 deg are shown. The B-Stark chords cross the 330 deg left and 330 deg right neutral beams. The angle between the 330 deg left neutral beam and the B-Stark chord is 57.8 deg. The angle between the vertical direction and the B-Stark chord is 59.9 deg. The neutral beams have a width of ~20 cm and a height of ~ 40 cm. General Atomics Report GA A26110 5

In order to maximize light throughput while maintaining narrow slit widths, custom fiber bundles were designed that are packed into two square ferrules at the plasma viewing end and packed into a line on the spectrometer end. The bundles each have 38 fibers with 200 µm core diameter. The two ends of the fiber bundle can be arranged to act as a single chord, to maximize light gathering, or as separate chords. The installed viewing optics are f /2.3 to allow for future upgrades to a faster spectrometer. A lens mask was installed to reduce geometrical Doppler broadening due to the change in viewing angle across the lens. We are using an available SPEX 3/4 m Czerney- Turner spectrometer ( f /6.8 ) coupled to a PixelVision CCD camera with 12 µm pixel pitch. The top and bottom halves of the chip are summed vertically, and pixels binned by two, resulting in 326 channels. This system has a dispersion of ~ 0.14 Å /channel, and an instrumental response with a FWHM of ~ 0.4 Å. An in-vessel calibration is performed to find the viewing and effective lens locations, and to characterize the intensity response. 6 General Atomics Report GA A26110

IV. SPECTRUM The D α spectrum is made up of emission from several sources. The B-Stark diagnostic relies on emission from the neutral beams; however background emission must also be taken into account in order to properly fit the spectrum. The neutral beams on DIII-D inject deuterium atoms at three energies due to molecular deuterium in the ion source [10]. In addition there is a continuum of energies between the third and half components due to molecular D 3 + breaking into D 2 + + D partway through acceleration in the ion source. The D α emission from each of these components, as well as the continuum, is Stark split and Doppler shifted. For typical values of the magnetic field and beam energy, emission from the full component is spectrally separated while the half and third components overlap. The separation between the Stark lines for the full component is ~ 1.0 Å. The width of the beam emission lines is dominated by geometrical Doppler broadening due to the divergence of the neutral beam [11]. This causes a Doppler broadening of the beam emission with a FWHM of ~ 1.6 Å. This line width is greater than the Stark spacing, and makes the individual lines difficult to distinguish. There are a number of other sources that contribute to the D α spectrum. There is D α and H α emission from neutral deuterium and hydrogen in the edge, both of which are Zeeman split. There is emission from re-neutralized deuterium around the neutral beam, which is Doppler shifted due to the plasma rotation and thermally broadened. Lastly, there are impurity lines from the beams and the plasma. Most of the components in the spectra are beam dependent, reducing the effectiveness of time slice subtraction in removing the background emission. General Atomics Report GA A26110 7

V. RESULTS A spectral fit is performed to extract the intensity ratio and line spacing (Fig. 2). The fitting is done using a modified version of the non-linear least squares fitting package, CERFIT [12,13]. Fig. 2. (Color On-line ONLY) Fit of a B-Stark spectra for shot 131875 at 2500 ms. Data is shown as crosses, the fit is shown as a solid line. Here the background is made up of one Gaussian and a constant term. The weighed residual is found from the difference between the data and the fit, divided by the standard deviation of the data. The reduced chi-squared is 1.1. The line spacing is assumed to be described by a linear Stark model. The fit variables in this model are the upper state level populations, beam velocity, effective electric field, and the intensity ratio of the π to σ components. We allow each of the beam components to have unique upper state populations. The background is described using Gaussians and up to a quadratic polynomial. In addition the spectrometer fiducial (central wavelength) is given as a fit variable. Shots where the neutral beams are injected into a low density gas (beam into gas) are used to find the line profiles and to calibrate the B-Stark system. A spectrum produced by firing a beam into gas shot without magnetic field is used to find the spectral profile for the lines from each beam energy component and to find an instrumental profile to use for the background lines. In addition to the in-vessel spatial calibration, a beam into gas with toroidal field shot is used to determine in-situ the viewing direction and the ratio of transmission of π to σ light. The magnetic field in these shots is purely toroidal and is assumed to have a 1/ R dependence. To obtain both the direction and transmission factor, measurements from two beams at different angles are necessary. General Atomics Report GA A26110 9

The B-Stark measurements compare well with values taken from EFIT using MSE polarimetry data, for both B and B θ / B T. In Fig. 3 we show B-Stark measurements from shot 131875. Measurements were taken with a time resolution of 10 ms. The major radius of the viewing location was found using the in-vessel calibration, while the viewing direction and transmission factor were found using a beam into gas calibration. The error in the measurement of B is 0.015 T or 1% and for the measurement of B θ / B T the error is 0.12 or 10%. These errors are found from the standard deviation of the final measurements over a period where the parameters are expected to be constant (around 2500 ms). The discrepancy in B changes from ~0.08 T to ~0.05 T over the time range analyzed. A number of shots have been analyzed and the discrepancy in B is not always seen. Fig. 3. (Color On-line ONLY) B θ /B T and B versus time for shot 131875. B-Stark measurements (crosses) are taken every 10 ms. EFIT with MSE polarimetry results (solid line) are calculated every 25 ms. The accuracy of these measurements are dependent on the quality of the spectral fits. The main difficulties in getting good fits are the wide line profiles due to the beam divergence, poor signal due to the need for high spectral resolution, and a complicated background. 10 General Atomics Report GA A26110

VI. FUTURE PLANS Work is continuing to improve the fitting model. In addition we plan to evaluate the use of an atomic code [14] to calculate the expected level populations. This will reduce the number of fit parameters, resulting in better accuracy in determining the π to σ ratio. There are several planned hardware upgrades including a new camera that will allow an expansion to multiple chords and a faster spectrometer in order to get better signal levels. General Atomics Report GA A26110 11

REFERENCES [1] K. H. Burrell, Phys. Plasmas 4, 1499 (1997). [2] L. Lao, J. Ferron, R. Groebner, W. Howl, H. John, E. Strait, and T. Taylor, Nucl. Fusion 30, 1035 (1990). [3] A. Malaquias, M. von Hellermann, S. Tugarinov, P. Lotte, N. Hawkes, M. Kuldkepp, E. Rachlew, A. Gorshkov, C. Walker, A. Costley, et al., Rev. Sci. Inst. 75, 3393 (2004). [4] K. Jakubowska, M. De Bock, R. Jaspers, M. G. von Hellermann, and L. Shmaenok, Rev. Sci. Inst. 75, 3475 (2004). [5] W. Mandl, R. C.Wolf, M. G. von Hellermann, and H. P. Summers, Plasma Phys. & Controlled Fusion 35, 1373 (1993). [6] R. Wolf, L. Eriksson, M. Hellermann, R. Koenig, W. Mandl, and F. Porcelli, Nucl. Fusion 33, 1835 (1993). [7] D. J. D. Hartog, D. Craig, D. A. Ennis, G. Fiksel, S. Gangadhara, D. J. Holly, J. C. Reardon, V. I. Davydenko, A. A. Ivanov, A. A. Lizunov, et al., Rev. Sci. Inst. 77, 10F122 (pages 8) (2006), URL http://link.aip.org/link/?rsi/77/10f122/1. [8] C. T. Holcomb, M. A. Makowski, R. J. Jayakumar, S. A. Allen, R. M. Ellis, R. Geer, D. Behne, K. L. Morris, L. G. Seppala, and J. M. Moller, Rev. Sci. Inst. 77, 10E506 (pages 3) (2006), URL http://link.aip.org/link/?rsi/77/10e506/1. [9] M. von Hellermann, M. de Bock, R. Jaspers, K. Jakubowska, R. Barnsley, C. Giroud, N. Hawkes, K. Zastrow, P. Lotte, R. Giannella, et al., Rev. Sci. Inst. 75, 3458 (2004). [10] B. W. Rice, K. H. Burrell, L. L. Lao, and Y. R. Lin-Liu, Phys. Rev. Lett. 79, 2694 (1997). [11] B. H. Bransden and C. Joachain, Physics of Atoms and Molecules (Pearson Education Limited, 2003), 2nd ed. [12] R. Hong and H. K. Chiu, Fusion Engineering, 2002. 19th Symposium on pp. 40 43 (2002). [13] H. Chiu, Fusion Tech. 34, 564 (1998). [14] R. P. Seraydarian, K. H. Burrell, N. H. Brooks, R. J. Groebner, and C. Kahn, Rev. Sci. Inst. 57, 155 (1986). [15] D. S. Bunch, D. M. Gay, and R. E. Welsch, ACM Trans. Math. Software 19, 109 (1993). [16] M. Gu, AIP Conference Proceedings 730, 127 (2004). General Atomics Report GA A26110 13

ACKNOWLEDGMENT Work supported by the U.S. Department of Energy under DE-FC02-04ER54698, DE- FG02-07ER54917 and DE-AC52-07NA27344. General Atomics Report GA A26110 15