Whole Tablet Measurements Using the Frontier Tablet Autosampler System

Similar documents
Whole Tablet Measurements Using the Spectrum One NTS Tablet Autosampler System

Verification of Pharmaceutical Raw Materials Using the Spectrum Two N FT-NIR Spectrometer

Instrumental Limitations for High Absorbance Measurements in Noise

RamanStation 400: a Versatile Platform for SERS Analysis

Defining quality standards for the analysis of solid samples

HYPHENATED TECHNOLOGY GUIDE

Putting Near-Infrared Spectroscopy (NIR) in the spotlight. 13. May 2006

HYPHENATED TECHNOLOGY GUIDE

High-throughput Quantification of DNA for NGS Library Prep with the Zephyr G3 Workstation and the VICTOR Nivo Plate Reader

Fast, Quantitative Analysis of Residual Solvents in Cannabis Concentrates

Traceable UV-Vis Reference Materials

PTG-NIR Powder Characterisation System (not yet released for selling to end users)

DairyGuard: Augmenting Nutritional Testing of Milk Powder with Adulterant Screening

The Characterization of Nanoparticle Element Oxide Slurries Used in Chemical-Mechanical Planarization by Single Particle ICP-MS

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

Measurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

An Automated Application Template for Dissolution Studies

Introduction to Fourier Transform Infrared Spectroscopy

Application Note: 130. Measurement of Lozenges and Whole Tablets using the Series 2000 Tablet Analyser

Application of Raman Spectroscopy for Noninvasive Detection of Target Compounds. Kyung-Min Lee

ICP-MS. High Resolution ICP-MS.

Design Considerations for a Variable Angle Absolute Reflectance Accessory For the LAMBDA 950/850/650 UV/Vis/NIR and UV/Vis Spectrophotometers

Detection of trace contamination on metal surfaces using the handheld Agilent 4100 ExoScan FTIR

Overcoming Interferences with the Thermo Scientific icap 7000 Plus Series ICP-OES

Meeting the Challenges of Soil Analysis with the Avio 200 ICP-OES

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

FLUORESCENCE APPLICATIONS

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Spectroscopy tools for PAT applications in the Pharmaceutical Industry

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

2.01 INFRARED ANALYZER

TECHNICAL DESCRIPTION SPECTRAFLOW ON LINE ANALYZER for BELT CONVEYOR APPLICATION

Everyday NMR. Innovation with Integrity. Why infer when you can be sure? NMR

QbD QUANTITATIVE MEASUREMENTS OF CQAS IN SOLID DOSAGE FORM UNIT OPERATIONS

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

Agilent Oil Analyzer: customizing analysis methods

STANDARD OPERATING PROCEDURES

THE INTRODUCTION OF PROCESS ANALYTICAL TECHNOLOGY, USING NEAR INFRARED ANALYSIS, TO A PHARMACEUTICAL BLENDING PROCESS

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

XR Analog Clock - Manual Setting Model Troubleshooting Guide

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

Water in Food 3 rd International Workshop. Water Analysis of Food Products with at-line and on-line FT-NIR Spectroscopy. Dr.

The Claviature of Gas Analysis

Introduction to Fourier Transform Infrared Spectroscopy

Perseverance. Experimentation. Knowledge.

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction

Analysis of Polyphenols in Saffron Petal Extracts with UHPLC/UV/MS

Chemistry Instrumental Analysis Lecture 15. Chem 4631

Formulation of Low Dose Medicines - Theory and Practice

Signal Level Considerations For Remote Diffuse Reflectance Analysis

AZtec LayerProbe TM. Layer thickness and composition characterisation in the SEM. ...the ultimate non-destructive, high-resolution solution.

Independence and Dependence in Calibration: A Discussion FDA and EMA Guidelines

Snowy Range Instruments

Reference Standards Page 156 For calibrating your spectrometer. PIKECalc Page 159 For FTIR sampling computations

Spectroscopy in Transmission

Basics of a/b Discrimination for Liquid Scintillation Counting

NIR Chemical Imaging as a Process Analytical Tool

CONFOCHECK. Innovation with Integrity. Infrared Protein Analysis FT-IR

Fourier transform infrared spectroscopy (FTIR) is a method used to obtain an infrared

Monitoring Emulsion Polymerization by Raman Spectroscopy

Compact Hydrogen Peroxide Sensor for Sterilization Cycle Monitoring

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

TECHNICAL DESCRIPTION SPECTRAFLOW ONLINE ANALYZER for CROSSBELT APPLICATION

The Vaisala AUTOSONDE AS41 OPERATIONAL EFFICIENCY AND RELIABILITY TO A TOTALLY NEW LEVEL.

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization

DOWNLOAD OR READ : INFRARED AND RAMAN SPECTROSCOPY CONCEPTS AND APPLICATIONS PDF EBOOK EPUB MOBI

The RX-6000 Sulfur in Oil Analyzer For the analysis of Sulfur in Oil and other elements from S to U

Reprinted from February Hydrocarbon

To Hy-Ternity and beyond. Boris Larchevêque, INDATECH

Aspen Polymers. Conceptual design and optimization of polymerization processes

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

Analysis of Polymers and Plastics. Innovation with Integrity. Quality Control & Failure Analysis FT-IR

Pulsar. Delivering NMR to your benchtop

Fourier Transform Infrared Spectroscopy (Perkin Elmer - Spectrum One)

for XPS surface analysis

S8 TIGER Series 2 for ASTM D 6443

APPLICATION INFORMATION

Simplified workflows for the Thermo Scientific icap TQ ICP-MS

Pharmaceutical Polymers for Tablets and Capsules

Peter L Warren, Pamela Y Shadforth ICI Technology, Wilton, Middlesbrough, U.K.

Geospatial natural disaster management

Alpha spectrometry systems. A users perspective. George Ham. 26 th May Date Month Year

USP Method Transfer and Routine Use Analysis of Irbesartan Tablets from HPLC to UPLC

OPERATING INSTRUCTIONS

Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites

Good manufacturing practices (GMPs)

Developments & Limitations in GSR Analysis

Application of Raman Spectroscopy for Detection of Aflatoxins and Fumonisins in Ground Maize Samples

Nanoscale IR spectroscopy of organic contaminants

Varian Galaxie Chromatography Data System for Preparative HPLC

Spatial Analysis with ArcGIS Pro STUDENT EDITION

Elemental analysis of river sediment using the Agilent 4200 MP-AES

X-Ray Net Weight Control of Pharmaceutical Products

Owlstone Nanotech Inc

Analysis of Polymers and Plastics. Innovation with Integrity. Quality Control & Failure Analysis FTIR

Transcription:

a p p l i c a t i o n N O T E Whole Tablet Measurements Using the Frontier Tablet Autosampler System FT-NIR Spectroscopy Introduction Recent advances in NIR technology have changed the ways in which both the pharmaceutical industry and the regulators view the current approaches to tablet testing in manufacturing. In 2001, among the FDA s top 10 reasons for product recall were problems with sub-potency and tablet dissolution. In addition, recent cases of cgmp violations have highlighted issues in tablet manufacturing. One area where the industry is seeking to improve its processes is in the blending area. After tablet pressing, measurement of uniformity of content usually involves taking a sample (typically 10 tablets) from the batch and performing individual assays by HPLC. The standard deviation of assay is intended to provide an idea of the uniformity of the blend. This measurement is required before batch release and can cause serious bottlenecks, especially if out-ofspecification results are generated. The HPLC technique used is slow, requires skilled analysts, provides little or no information on the matrix and destroys the sample. Analysts are actively seeking faster, non-destructive methods which can provide more information on the sample and are capable of being used by less experienced operators. NIR now offers the possibility of performing non-destructive, whole tablet testing at much higher speeds and also provides more sample matrix information. It is also readily automated thus providing the potential for more and/or faster tablet testing using less specialized operators. More efficient, more informative measurement in this area is a key factor in delivering more process understanding; an objective pursued by industry and regulators alike. This note describes an example showing the application of NIR tablet transmission measurements to determine the active content of whole tablets.

Method The aim of the study was to present whole, coated tablets to the analyser to determine active level, then to perform a series of analyses on a batch of tablets to provide information on the uniformity of the batch. Using the system described below, the samples are presented horizontally to the spectrometer and a masked beam illuminates each sample with a spot diameter of 6 mm. The power of the beam at the sample position is relatively low (ca 200 mw) in order to avoid unwanted heating problems in the tablet, which could interfere with results. The tablets to be tested were 350 mg in weight, ca 12 mm in length and ca. 5-mm thick. Using the NIR transmission approach, it is important to present the sample to the instrument in such a way as to minimize stray radiation from the instrument passing around the side of the sample and going onto the detector. To overcome this potential problem, special custom tablet holders may be fabricated to ensure a tight fit between tablet holder and tablet. An illustration of the sample holders is shown in Figure 1. The Spectrum One NTS FT-NIR spectrometer was equipped with the Tablet Autosampler sampling system. The system includes detectors for both transmission and reflectance measurement, and an automated sample wheel for batch measurements (Figure 2). Dedicated detectors allow for optimized operation for this potentially demanding measurement. The method development and system integration software (AssureID version 2) provides simple construction of methods which can be easily readied for effective push-button operation in the plant (Figure 3). Given the method is generally used by users in a production environment numerous system design features in both software and hardware are oriented towards more robust methods from sample presentation to the software workflows designed to minimize the likelihood of operational errors. Figure 1: Tablet holder for NIR transmission measurements. Figure 2: Frontier NTS tablet autosampler system. Figure 3: AssureID software for tablet analysis automation.

Calibration When setting up the system for analysis, it is necessary to calibrate the system using a training set of samples which span the target assay value usually 80-120% of target value is chosen. This can sometimes be the slowest part of the system implementation as it can be difficult to obtain samples which are so "off-spec," especially for mature processes. Hence it is often most effective to implement this technology earlier in the product lifecycle in the formulation development or scale-up stages when a wider range of calibration tablets is more likely to be at hand. The target concentration for this product was 20 mg per 350-mg tablet. To generate the calibration, samples ranging from 16-mg content to 24-mg content were scanned and the Quant+ quantitative software application used to generate the calibration equation relating the spectral changes to the concentration values. The Quant+ software offers a full suite of diagnostics to help optimise the calibration before incorporating the model into the analysis workflow. For this study, it was found adequate to use a sample training set, a calibration set of 20 samples and to test the model with 68 independent samples, spanning the same concentration range (validation set) were used. Calibration details are shown in Table 1. When the primary property of interest is chemical composition such as active content, there are some steps that can be taken to improve the robustness of the method to operator and/or sampling variability. For example, the choice of using derivative spectra for the analysis can considerably improve the robustness of the calibration with respect to sampling variations such as tablet height position and for this method it was found that a smoothed second derivative approach worked well. It is a very simple operation in Quant+ to switch-on various forms of data pre-treatment and to view the effects on the calibration performance. The calibration model used and certain sampling precautions are key factors in determining the ultimate robustness of the method in everyday use and, as a rule, extra care taken at this stage is easily paid back in terms of the reliability of the final method. Relevant instrument data collection parameters for optimum results for this sample set are shown in Table 2. For the batch calculations, 10 tablets were placed into the tablet holders which in turn were mounted onto the wheel. It is also advisable to generate a tablet presentation SOP to ensure correct positioning of the tablets into the autosampler between different operators. The AssureID software allows users to display their own SOP prior to analysis. This can contain product-specific information which is linked to that particular method. Number of calibration samples 20 Number of validation samples 68 Calibration algorithm Partial least squares (PLS1) Data pre-processing 2nd derivative, 25 point smooth width Number of PLS factors 2 Standard error of calibration (20 samples)/mg 0.8 Standard error of prediction (60 samples)/mg 0.9 Table 1: Quantitative calibration details. Scan range/cm -1 12000-8500 Resolution/cm -1 16 Scan time/per sample 60 sec Scan time per batch 10 min Apodization Strong Background reference Open beam Table 2: Instrument details for tablet assay measurement.

Results and Discussion For this analysis, batches of 10 samples were analysed using the PLS1 method outlined above and simple batch statistics including the mean assay value, standard deviation, and minimum and maximum batch values were calculated and output to the reports and secure database. The database may be queried within the AssureID application to show result trends, revealing important information about the process. An example plot is shown in Figure 4. A typical output from a query is shown in the figure below. Individual records may also be examined, tracing calculated results to associated instrument conditions, spectra and system check results, Figure 5. This kind of display provides useful information on a number of important process issues, assisting the overall understanding of the process: Potency drift during the run of the tablet press Potency variability between runs on a tablet press Potency variability between tablet presses Potency variability with differing blending conditions Direct comparison with HPLC assay values. In general due to the much faster and more representative NIR analysis it is possible to obtain trend plots with far more data points than the corresponding HPLC trend plots. This kind of information is beneficial not only from the point of view of improved understanding of the blending/pressing from the point of view of potency, but can be extended to provide similar information on other ingredients, and in favourable cases some physical properties such as coating thickness and hardness with no significant impact of on batch analysis time. Next, it is envisaged tablet analysis will be extended to the following: Other matrix components. Physical properties such as hardness and/or coating thickness. Powder blends before tablet pressing. This will be possible by extracting sample from the blender using a sample thief and pressing the blend into wafers prior to NIR transmission analysis. Other uncoated tablets where moisture will be measured in addition to active. Moisture will be measured by reflectance and active content by transmission. Figure 4: Trend display showing variation of potency within a batch. Figure 5: Tablet analysis database display.

As the technique becomes more accepted by the industry, it is expected that more "calibration-free" approaches will be adopted in tablet analysis. Such methods skip the step of developing a model relating the spectral changes to properties of interest for a pre-analysed training set of samples and applying the model to predict properties for the samples. In this case changes in the spectra are related directly to some variability in the process. For example, the standard deviation of an isolated active peak height may be related directly to uniformity of a batch thereby eliminating the need to calibrate using samples which are already beyond the bounds of normal process variability. This approach may be easier for some products, where the active absorption in the spectrum is very clearly differentiated from the other ingredients in the spectrum. For other products, however, the distinction is less clear making it necessary to introduce more sophisticated data analysis techniques. Figure 6 shows the NIR transmission spectra of two different products. In Figure 6a, the active band is not overlapped with those of the other ingredients and simple band height measurements can be correlated directly with the potency. In Figure 6b, the active band is overlapped with the absorption of the other ingredients and for this particular product, a chemometricsbased approach worked better. The method can be run in parallel with the conventional HPLC method during the validation stage. Figure 6a: NIR transmission spectra where active absorption is separated from other components in the matrix. Spectra from 0-, 10-, 50-, 200-mg strength tablets. Figure 6b: NIR transmission spectra where active absorption is overlapped with other ingredients. The two traces show spectra from tablets of two strengths, ca 5 and 10% active, where the absorption due to the active indicated. Conclusion The use of NIR transmission for whole tablet analysis can effectively improve the efficiency of the tablet pressing step by allowing faster feedback into the process than the conventional HPLC method. NIR can be an order of magnitude faster. More analytical information per sample and more tablet analyses in a given time greatly increases process understanding. Increasing scrutiny from the regulators and the drive for improved process understanding will ensure the technique will become more widespread. The anticipated development of official guidelines for setting up and testing NIR transmission methods in a similar manner to the NIR reflectance methods will be another factor in the growth of this exciting development. As the pharmaceutical industry begins to realize the benefits of the new technologies for NIR testing, it will then be just a matter of time before NIR becomes established as a standard method used as commonly as mid-ir in pharmacopeial methods. PerkinElmer, Inc. 940 Winter Street Waltham, MA 02451 USA P: (800) 762-4000 or (+1) 203-925-4602 www.perkinelmer.com For a complete listing of our global offices, visit www.perkinelmer.com/contactus Copyright 2010, PerkinElmer, Inc. All rights reserved. PerkinElmer is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners. 006832A_02 Printed in United Kingdom