Auftrags-Nr.: Order No.: EN ISO 9806:2013 Solar energy - Solar thermal collectors - Test methods

Similar documents
Auftrags-Nr.: Order No.: Auftragsdatum: Order date: LG Electronics Inc. 168, Suchul-daero, Gumi-si, Gyeongsangbuk-do, 39368, Korea

1 / 17. TÜV Rheinland (Shanghai) Co., Ltd Solar/ Fuelcell Technologies. Test Report

Collector test according to EN ,2:2002

a Chi Mei Corporation 59-1, San Chia, Jen Te, Tainan City 71702, Taiwan, R.O.C. ACRYLONITRILE-BUTADIENE-STYRENE COPOLYMER

REPORT NUMBER: GZU-001 ORIGINAL ISSUE DATE:

REPORT NUMBER: GZU -001 ORIGINAL ISSUE DATE:

m 001. Chi Mei Corporation 59-1, San Chia, Jen Te, Tainan City 71702, Taiwan, R.O.C. TÜV Rheinland (Shanghai) Co., Ltd.

p Chi Mei Corporation 59-1, San Chia, Jen Te, Tainan City 71702, Taiwan, R.O.C. ACRYLONITRILE-BUTADIENE-STYRENE COPOLYMER

q Chi Mei Corporation 59-1, San Chia, Jen Te, Tainan City 71702, Taiwan, R.O.C. ACRYLONITRILE-BUTADIENE-STYRENE COPOLYMER

d 001. Formosa Chemicals & Fibre Corporation 201, Tung Hwa N. Rd., Taipei, Taiwan, R.O.C. TÜV Rheinland Hong Kong Ltd.

TÜV Rheinland PTL, LLC 2210 South Roosevelt Street Tempe, AZ Test Report

Collector test according to EN ,2 : 2006

Collector test according to EN ,2:2006

Report of Performance Test according to EN for a Glazed Solar Collector

Report of Performance Test according to EN for a Glazed Solar Collector

Collector test according to EN ,2:2006

Collector test according to EN ,2:2006

Solar Flat Plate Thermal Collector

UNIT FOUR SOLAR COLLECTORS

Development and Validation of Flat-Plate Collector Testing Procedures

Development and Validation of Flat-Plate Collector Testing Procedures

Experimental investigation of the performance of a Parabolic Trough Collector (PTC) installed in Cyprus

1D and 3D Simulation. C. Hochenauer

SKN_N0115R0. Test results of TiNOX energy_al 20/8 2009

Report TAG3-UA-1212-E07 Testing of the transmission and the g-value of a polycarbonate multiwall panel AKYVER 16/7 IR Control Grey

DETAILED MODELING OF SOLAR FLAT-PLATE COLLECTORS WITH DESIGN TOOL KOLEKTOR 2.2

Determination of installed thermal resistance into a roof of TRISO-SUPER 12 BOOST R

Qualification Test of Solar Absorber Coating Durability - Part 1

Simplified Collector Performance Model

Product documentation

Development and Validation of Flat-Plate Collector Testing Procedures

OPTIMIZATION of the GEOMETRY & MATERIAL of SOLAR WATER HEATERS.

Window air permeability measurement, watertightness and resistance to wind load (designation of the test)

Department of Energy Science & Engineering, IIT Bombay, Mumbai, India. *Corresponding author: Tel: ,

Model 3024 Albedometer. User s Manual 1165 NATIONAL DRIVE SACRAMENTO, CALIFORNIA WWW. ALLWEATHERINC. COM

Contents... 1 Intro... 1 Giving guarantees... 2

Test Results: Results of the test period on 06/19/16 using the Equivalent CTS Method: Thermal transmittance at test conditions (U s ):

Deutschen Kalibrierdienst D-K

CERTIFICATE of Product Conformity (QAL1 )

SL27C SL32C. ScreenLine. Technical Catalogue. english. double-glazed unit 27 mm 32 mm

Experimental analysis of thermal performance of flat plate and evacuated tube solar collectors in stationary standard and daily conditions

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

1/54 Circulation pump, safety valve, expansion vessel

Instruction for erection and use and examination report for the heavy-load support column. RUX-VS 500 with jack RUX-VS 500 with jack mit Absenkkeil

Report No: NCTL NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 12/14/15

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 6, Issue 11, May 2017

High-ohmic/high-voltage resistors

Determining of Thermal Conductivity Coefficient of Pressed Straw (Name of test)

EXPERIMENTAL STUDY ON A CASCADED PCM STORAGE RECEIVER FOR PARABOLIC DISH COLLECTOR

Customer: Ashton Industrial Sales Ltd. South Road, Harlow Essex CM20 2AR UNITED KINGDOM. Project/Customer: Profilex HM spacer

HEAT LOSS MEASUREMENTS ON PARABOLIC TROUGH RECEIVERS

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

ISEmax CAM40/CAS40. Technical Information

ISO/TC 180/SC. Date: ISO/xxxx yyyy. Secretariat: SA. Solar energy Collector fields Check of performance. Énergie solaire xxx yyy

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Calculating the heat transfer coefficient of frame profiles with internal cavities

Operating Instructions for Digital Manometer. Model: MAN-SD

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

Page 2 of 14 Report Ref. No

Experimental and Theoretical Evaluation of the Overall Heat Loss Coefficient of a Vacuum Tube Solar Collector

Thermal Analysis of Solar Collectors

The influence of solar radiation on the distribution of temperatures in historic masonry

SHANGHAI MYLCH WINDOWS & DOORS THERMAL PERFORMANCE TEST REPORT

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

PRODUCT DATA SHEET. Eagle Eye Outdoor LED Module 3000K. RoHS Compliant. CUSTOMER :. DATE : REV : Rev. 1.0.

TFI Report Sound Absorption Impact Sound Insulation

LP PYRA Installation and Mounting of the Pyranometer for the Measurement of Global Radiation:

LED Entryway Light RoHS

CERTIFICATE of Product Conformity (QAL1 )

EX-EMERGENCY LIGHT FITTINGS

EXPERIMENTAL AND NUMERICAL STUDY THE HEAT TRANSFER OF FLAT PLATE SOLAR COLLECTOR BY USING NANOFLUID UNDER SOLAR SIMULATION

Expedited Filing Draft August 22, 2017

TREES Training for Renovated Energy Efficient Social housing

Installation Manual. Installation manual for PerfectEnergy Solar Modules. Content

EXPERIMENTAL INVESTIGATION OF DIFFERENT TRACKING MODES OF THE PARABOLIC TROUGH COLLECTOR

Page 1. Name:

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

COMBINED MEASUREMENT OF THERMAL AND OPTICAL PROPERTIES OF RECEIVERS FOR PARABOLIC TROUGH COLLECTORS

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

TFI Report Sound Absorption Impact Sound Insulation

Characterization of high temperature solar thermal selective absorber coatings at operation temperature

TEST CERTIFICATES OR REPORTS ISSUED BY VEIKI-VNL LTD.

High Ohmic/High Voltage Resistors

Determination of thermal transmittance of window (test title)

Coolant. Circuits Chip

Monthly performance of passive and active solar stills for different Indian climatic conditions

Certificate: / 30. April 2015

COMBINATION OF TAGUCHI METHOD AND ARTIFICIAL INTELLIGENCE TECHNIQUES FOR THE OPTIMAL DESIGN OF FLAT-PLATE COLLECTORS

Winter Night. Thermos 6mm Outdoors # #

Solar Tube Impact Test Report

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: NU VISTA WD, INC. SERIES/MODEL: Malibu 250 T TYPE: Fixed

TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000

COVENANT UNIVERSITY NIGERIA TUTORIAL KIT OMEGA SEMESTER PROGRAMME: MECHANICAL ENGINEERING

SPECIFICATION SS 51/9 400KV COUPLING CAPACITORS FOR POWER LINE CARRIER SYSTEM

HEAT LOSS CHARACTERISTICS OF A ROOF INTEGRATED SOLAR MICRO-CONCENTRATING COLLECTOR

A SIMPLE MODEL FOR THE DYNAMIC COMPUTATION OF BUILDING HEATING AND COOLING DEMAND. Kai Sirén AALTO UNIVERSITY

Chapter 5 MATHEMATICAL MODELING OF THE EVACATED SOLAR COLLECTOR. 5.1 Thermal Model of Solar Collector System

WUFI Workshop NBI / SINTEF 2008 Radiation Effects On Exterior Surfaces

NFRC THERMAL TEST SUMMARY REPORT January 27, 1999 Test Specimen

Fabric Sport. Measurement of sound absorption in a reverberation room according to EN ISO 354. Test Report No. M102794/02

Transcription:

Produkte Prüfbericht-Nr.: 21239899.002 Auftrags-Nr.: Order No.: 21239899 Kunden-Referenz-Nr.: Client Reference No.: 3141884 Auftragsdatum: Order date: 23 January 2017 Auftraggeber: Client: Viessmann Faulquemont S.A.S. Prüfgegenstand: Test item: Solar thermal collector Seite 1 von 29 Page 1 of 29 (for add. information see page 3) Bezeichnung / Typ-Nr.: Vitosol 300-TM SP3C 1.51m² Identification / Type No.: Auftrags-Inhalt: Order content: A collector test in accordance with EN ISO 9806:2013 should be performed with the aim of certification. Prüfgrundlage: Test specification: EN ISO 9806:2013 Solar energy - Solar thermal collectors - Test methods Wareneingangsdatum: 03 January 2017 Date of receipt: 22 February 2017 Prüfmuster-Nr.: Test sample No.: see "List of test samples" Prüfzeitraum: Testing period: 02 February 2017 22 June 2017 Ort der Prüfung: Place of testing: Cologne Prüflaboratorium: Testing laboratory: Solar Energy Assessment Center Prüfergebnis*: Test result*: Pass Viessmann Werke GmbH & Co. KG geprüft von / tested by: kontrolliert von / reviewed by: 11 July 2017 Jürgen Sommer / Project manager 11 July 2017 Ulrich Fritzsche / Team Manager Datum Date Name / Stellung Name / Position Datum Date Name / Stellung Name / Position Unterschrift Signature Unterschrift Signature Sonstiges / Other: add. test specifications: - "Solar Keymark Scheme Rules" - EN 12975-1:2006+A1:2010 "Thermal solar systems and components - Solar collectors Part 1: General requirements" - SRCC OG 100 Operating guidelines for certifying solar collectors - ICC 901/SRCC100-2015 Solar Thermal Collector Standard " Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: 1 = sehr gut 2 = gut P(ass) = entspricht o.g. Prüfgrundlage(n) 3 = befriedigend F(ail) = entspricht nicht o.g. Prüfgrundlage(n) 4 = ausreichend N/A = nicht anwendbar 5 = mangelhaft N/T = nicht getestet Legend: 1 = very good 2 = good P(ass) = passed a.m. test specification(s) 3 = satisfactory F(ail) = failed a.m. test specification(s) 4 = sufficient N/A = not applicable 5 = poor N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TÜV Rheinland Energie und Umwelt GmbH Am Grauen Stein 51105 Köln Germany Tel.: +49 221 806-5222 Fax: +49 221 806-1350 Mail: solarenergy@de.tuv.com Web: www.tuv.com/solarthermal

Seite 2 von 29 Page 2 of 29 Liste der verwendeten Prüfmittel List of used test equipment Prüfmittel Test equipment Prüfmittel-Nr. / ID-Nr. Equipment No. / ID-No. Nächste Kalibrierung Next calibration All equipment used for tests, including equipment for subsidiary measurements having a significant effect on the accuracy or validity of the result of the test is calibrated before being put into service. The laboratory has an established programme and procedure for the calibration of its equipment according to EN ISO/IEC 17025 (Reg. no.: D-PL-11120-01-00).

Seite 3 von 29 Page 3 of 29 1 Name/Adresse des Herstellers Name/Address of manufacturer 2 Name/Adresse des Berichtsinhabers Name/Address of owner of report 3 Handelsname Brand name 4 Zeichnungs-Nr. Drawing document number 5 Sonstiges Additional information Rain penetration test Viessmann Faulquemont S.A.S. Avenue André Gouy 57380 Faulquemont France Viessmann Werke GmbH & Co. KG Viessmannstrasse 1 35107 Allendorf Germany Vitosol 300-TM SP3C 1.51m² Part of Constructional data Also useable in horizontal orientation Also available as 3.03 m² version Hail impact test Mechanical load test IAM determination

Seite 4 von 29 Page 4 of 29 - Result summary table Test Chapter of standard* Date [DD Month YYYY] Start End Summary of main test results (Pre-) Exposure 11 1 / 401.7 2 Rain penetration 14 1 / 401.17 2 20 February 2017 06 April 2017 Class A P 29 May 2017 No visual damages P Mechanical load 16 1 / 401.18 2 12 June 2017 22 June 2017 Snow: +5600 Pa Wind: +6900 / -1450 Pa Suction: -1400 Pa P Impact resistance 17 1 / 302.1 2 09 June 2017 22 June 2017 25 mm ice ball; 0.6 m drop height P Final inspection 18 1 / 401.19 2 Thermal performance 20 1 / 401.14.1 2 Incident angle modifier 27 1 / 401.15 2 Pressure drop 28 1 / 401.16 2 22 June 2017 No visual damages P 11 April 2017 11 April 2017 No visual damages P 17 April 2017 27 April 2017 No visual damages P 02 June 2017 No visual damages P Supplementary information: For performance coefficients see Final performance evaluation *Chapter No. 1 : according to EN ISO 9806 (chapter information used in report) *Chapter No. 2 :according to ICC901/SRCC 100

Seite 5 von 29 Page 5 of 29 - Constructional Data Basic data Name of manufacturer Brand name Viessmann Faulquemont S.A.S. Viessmann Type name Vitosol 300-TM SP3C 1.51 m² Construction type/category Evacuated tube collector Year of production 2016 / 2017 Collector unit Data *** Drawing-/Spec.-No. Dimension (l / w / h) [mm] 2244 / 1052 / 150 C Gross area [m²] 2.36 D Aperture area [m²] 1.60 D Absorber area [m²] 1.51 C Weight empty [kg] 40 C Fluid content [l] 0.87 C Flow rate (recommended) [kg/s] - - - - - - Evacuated tube orientation vertical / horizontal C Flow pattern serial C 7749030 7668730 Enclosure Dimension (l / w / h) [mm] Main material 224 / 1052 / 150 aluminium C C 7657113-04 7594341-05 5876020-04 Side material Polycarbonate with glass fiber C 7657114-01 Additional material Polycarbonate with glass fiber C 6062334-01 Frame fastening method Bottom profile material Sealing and add. polymeric parts clamped / stacked / screwed Aluminium / polymeric listed separately C C - - - 7594703-04 5878310-06 7594336-04 5877170-06 5886090-01 7398787-01 6062330-02 7657163-02 6062341-02 *** D = determined by laboratory; C = confirmed by laboratory; M = manufacturer information

Seite 6 von 29 Page 6 of 29 Cover Data *** Drawing-/Spec.-No. Number of covers 1 C Material Borosilicated glazing C Aperture area (l) [mm] 1990 D Outer diameter [mm] 71 C Thickness [mm] 2.0 C Solar transmittance 0.92 M Glazing surface characteristics clear C 7592909-04 5982552-04 5880865-05 Material aluminium C Absorber Dimension (l / w) [mm] 1980 / 63.7 C Thickness [mm] 0.3 C Number of parts 24 C Solar absorptance α 0.95 M Hemispherical emittance ε 0.04 M Surface treatment Selective (Tinox) M Bond between riser and plate Ultrasonic welded C Absorber to glazing distance [mm] 28 / nearly centered C 7649836-05 7649833-03 7649690-04 7649638-03 6050012-03 5886072-01 Main header material copper C Header Main header diameter [mm] double hydroformed element C Main header thickness [mm] 1.25 C 7594894-05 6031738-04 Main header length [mm] 1084 C Additional header material stainless steel (as clamp) C *** D = determined by laboratory; C = confirmed by laboratory; M = manufacturer information

Seite 7 von 29 Page 7 of 29 Insulation (main) Data *** Drawing-/Spec.-No. Material Melamin C Thickness [mm] 20 to 52 C Thermal conductivity [W/(m²*K)] 0.035 M - - - 5877926-03 6070848-01 6070983-01 Sealing / Polymeric parts Frame to side caps PE-foam M 5887188-01 Frame to header tube Silicon-based M 5895706-01 Frame evacuated tube EPDM-based M 6067247-01 M 6065396-04 Head of glass tube Thermo compressed bonding 7592879-03 Glass tube fastener Polycarbonate with glass fiber M 6061025-01 Strap of glass tube EPDM-based M 5877695-05 Heat Pipe Material copper C Number of pipes 24 C Distance between risers [mm] 84 C Heating section diameter [mm] 12 C Heating section thickness [mm] 0.6 C Heating section length [mm] 2063 C Condenser diameter [mm] 22 C Condenser thickness [mm] 1 C Condenser length [mm] 65 C 7649836-05 7649639-03 7649643-07 6050000-03 7779907-01 6078254-02 6049999-06 *** D = determined by laboratory; C = confirmed by laboratory; M = manufacturer information

Seite 8 von 29 Page 8 of 29 Maximum operating temperature [ C] Limitations Data *** Drawing-/Spec.-No. - - - M Maximum operating pressure at maximum temperature of operation [kpa] 600 (800; with alt. safety equipment) M Minimum tilt angle [ ] 3 M Maximum tilt angle [ ] 90 M - - - Recommended heat transfer medium Water-glycol mixture M Collector mounting wall, flat roof, on roof M Other limitations - - - - - - *** D = determined by laboratory; C = confirmed by laboratory; M = manufacturer information

Seite 9 von 29 Page 9 of 29 - List of test samples Test Sample Picking according to Solar Keymark Scheme Rules Date [DD/MM/YYYY] by (randomly) 13/12/2016 (tubes) 20/02/2017 (manifolds) Sommer Sample No. Sample S/N Remarks / constructional characteristics 20170002988 7749030701010108 Assembly of manifold and tube delivery - Visual inspection (Initial) Test date [DD/MM/YYYY] 02/02/2017 and 22/02/2017 Sample No. Nature and position of initial findings 20170002988 Main test sample; also used for single reliability test sequences P

Seite 10 von 29 Page 10 of 29 11 Exposure and pre-exposure test Summary of outdoor exposure results Test date [DD/MM/YYYY] 02/03/2017 to 06/04/2017 Collector tilt angle [ from horizontal] 35 Sample No. 20170002988 No. of days [d] Irradiation energy W/m² Mean ambient temperature C Min. ambient temperature C Max. ambient temperature C 35 383.0 10.0 0.0 26.5 P Climate class [W/m² and C] Time period in climate class min] Mean ambient temperature C Min. ambient temperature C Max. ambient temperature C 1000/20 Class A - - - - - - - - - - - - N/A Summary of solar simulator exposure results Test date [DD/MM/YYYY] 24/02/2017 to 01/03/2017 Collector tilt angle [ from horizontal] 3 Sample No. No. of days [d] Irradiation energy W/m² Climate class [W/m² and C] Time period in climate class min] Mean ambient temperature C 20170002988 5 291.7 1000/20 Class A 80 27.0 P Supplementary information: Sample No. Total irradiation energy W/m² Total result of exposure test Time period in climate class min] Final climate class [W/m² and C] 20170002988 674.7 80 1000/20 Class A P

Seite 11 von 29 Page 11 of 29 14 Rain penetration test Test date [DD/MM/YYYY] 29/06/2017 Collector mounted on Collector tilt angle [ from horizontal] 3 Open frame Sample No. Test duration [h] Detection of water penetration by Hours after spray [h] Water ingress [g] 20170002988 4 weighing / visual inspection 4 9 P Supplementary information: Because of a more critical set-up the rain penetration test was done with smaller test sample; 16 Mechanical load test with positive or negative pressure Test date [DD/MM/YYYY] 12/06/2017 to 22/06/2017 Method used to load the collector positive Method used to load the collector negative Single weights Tensile machine Sample No. Max. positive load [Pa] Remaining deflection [mm] Max. negative load [Pa] Remaining deflection [mm] 20170002987 6900* / 5600** 3 - - - 0 P 20170002988 - - - 0 1450* / 1400*** 0 P Supplementary information: Because of the better handling (size of the machine) the tensile test was done with smaller test sample; The final load is calculated to the most critical areas defined: * for load case wind frontal ; by load on total projected area; ** for load case snow ; by load on gross area; *** for load case wind suction ; by load on projected tube area

Seite 12 von 29 Page 12 of 29 17 Impact resistance test (with ice balls) Test date [DD/MM/YYYY] 09/06/2017 Method used for impact resistance acc. to Sample tilt angle [ from horizontal] 90 Direction of shoot [ ] Impact angle [ from sample surface] 90 Clause 17.4 Ice balls 0 (horizontal) Storage temperature of ice ball [ C] - 4 +/- 2 Diameter of ice ball [mm] 25.0 +/- 5% Weight of ice ball [g] 7.5 +/- 5% Velocity of ice ball [m/s ] 23.0 +/- 5% Sample No. 20170002988 No. Supplementary information: Location of impact [from left] Mass of ball [g] Velocity of ball [m/s] Impact energy [J] 1 7.52 24.10 2.18 P top 2 7.36 23.06 1.96 P Tube 4 3 7.38 23.54 2.04 P bottom 4 7.39 23.81 2.09 P Because of the better handling (size of the test facility) the impact test was done with smaller test sample; According to ICC901/SRCC 100, the steel ball test is required for collectors using not tempered glass. Marking of value information: *value to low; NOT valid; **value to high, NOT valid; ***value to high, BUT valid

Seite 13 von 29 Page 13 of 29 17 Impact resistance test (with steel ball) Test date [DD/MM/YYYY] 22/06/2017 Method used for impact resistance acc. to Clause 17.5 Steel balls Collector tilt angle [ from horizontal] 0 Test performed using Vertical drop Diameter of ball [mm] 33.3 Weight of steel ball [g] 151 Resulting maximum height [m] 0.6 Sample No. 20170002988 Supplementary information: Location of impact Height of ball [m] Passed drop Tube 1 top / bottom 0.4 2 / 2 P Tube 3 top / bottom 0.6 2 / 2 P Tube 10 top 0.8 1* F Tube 11 top 0.8 1* F Because of the better handling (size of the test facility) the impact test was done with smaller test sample; According to ICC901/SRCC 100, the steel ball test is required for collectors using not tempered glass *one drop on position passed; 2 nd drop failed

Seite 14 von 29 Page 14 of 29 18 Final inspection Test date [DD/MM/YYYY] 22/06/2017 Scale of potential problem 0 No problem 1 Requirement apart from testing not fulfilled 2 Requirements for testing not fulfilled ~ Inspection to establish the condition not possible Sample No. Collector component Potential problem Evaluation a) Collector box/fasteners Cracking/wrapping/corrosion/ rain penetration 0 b) Mountings/structure Strength/safety c) Seals/gaskets Cracking/adhesion/elasticity 0 0 20170002988 d) Cover/reflector Cracking/crazing/buckling/delamination/ wrapping/outgassing 0 e) Absorber coating Cracking/crazing/blistering 0 e²) Absorber tubes and headers Deformation/corrosion/leakage/ loss of bonding 0 e³) Absorber mountings Deformation//corrosion 0 f) Insulation Water retention/outgassing/ degradation 0

Seite 15 von 29 Page 15 of 29 20 Performance testing of fluid heating collectors (45 ) Test date [DD/MM/YYYY] 11/04/2017 Method used for determination acc. to Clause 20.2 Steady state efficiency test using a solar irradiance simulator and Clause 24 Performance test procedures Used type of lamps ATLAS MHT 4010 Shading of long wave radiation by Collector tilt angle [ from horizontal] 45 Artificial cold sky Orientation of absorber tubes Used fluid vertical Water Mean solar irradiance [W/m²] 852 Long wave irradiance IRnet [W/m²] 4 Mean wind speed [m/s] 3.3 Mean mass flow [kg/s] 0.047 Collector performance coefficients ** (45 ) Sample No. Maximum power peak (at G * = 1000 W/m²) 20170002988 1200 based on Gross area [m²] Aperture area [m²] Absorber area [m²] 2.360 1.600 1.510 (+/- Standard deviation) eta0 hem * 0.508 (+/- 0.000) 0.750 (+/- 0.000) 0.795 (+/- 0.000) eta0 beam 0.511 (calculated) 0.754 (calculated) 0.799 (calculated) a 1 1.178 (+/- 0.021) 1.738 (+/- 0.031) 1.841 (+/- 0.033) a 2 0.005 (+/- 0.000) 0.008 (+/- 0.000) 0.008 (+/- 0.000) Supplementary information: * Based on the comparison between in- & outdoor measurement the given values will be corrected according to chapter 20.2.2 of EN ISO 9806:2013. For final evaluated collector performance results see Final performance evaluation. ** For Collector performance coefficients based on gross area and inlet temperature (acc. to SRCC) see General remarks

Seite 16 von 29 Page 16 of 29 20 Performance testing of fluid heating collectors (3 ) Test date [DD/MM/YYYY] 11/04/2017 Method used for determination acc. to Clause 20.2 Steady state efficiency test using a solar irradiance simulator and Clause 24 Performance test procedures Used type of lamps ATLAS MHT 4010 Shading of long wave radiation by Collector tilt angle [ from horizontal] 3 Artificial cold sky Orientation of absorber tubes Used fluid vertical Water Mean solar irradiance [W/m²] 852 Long wave irradiance IRnet [W/m²] 4 Mean wind speed [m/s] 3.3 Mean mass flow [kg/s] 0.047 Collector performance coefficients ** (3 ) Sample No. Maximum power peak (at G * = 1000 W/m²) 20170002988 1184 based on Gross area [m²] Aperture area [m²] Absorber area [m²] 2.360 1.600 1.510 (+/- Standard deviation) eta0 hem * 0.502 (+/- 0.000) 0.740 (+/- 0.000) 0.784 (+/- 0.000) eta0 beam 0.505 (calculated) 0.744 (calculated) 0.789 (calculated) a 1 1.292 (+/- 0.007) 1.906 (+/- 0.011) 2.020 (+/- 0.012) a 2 0.004 (+/- 0.000) 0.006 (+/- 0.000) 0.006 (+/- 0.000) Supplementary information: * Based on the comparison between in- & outdoor measurement the given values will be corrected according to chapter 20.2.2 of EN ISO 9806:2013. For final evaluated collector performance results see Final performance evaluation. ** For Collector performance coefficients based on gross area and inlet temperature (acc. to SRCC) see General remarks

Seite 17 von 29 Page 17 of 29 26.3.2 Determination of effective thermal capacity Test date [DD/MM/YYYY] 22/06/2017 Method used for determination acc. to Effective thermal capacity per collector [J/K] Effective thermal capacity per m² gross area [J/(K*m²)] Sample No. 20170002988 Clause 26.3 Calculation method 9.39 3.98 Effective thermal capacity of elements Per collector unit [J/K] Per m² gross area [J/(K*m²)] Absorber 3.91 1.66 Insulation 0.04 0.02 Heat transfer fluid 3.64 1.54 External glazing 1.80 0.76 26.4 Determination of collector time constant Test date [DD/MM/YYYY] 11/04/2017 Method used for determination Effective thermal capacity per m² gross area [kj/(k*m²)] Sample No. Solar simulator - - - Collector time constant c [s] 20170002988 182 Supplementary information:

Seite 18 von 29 Page 18 of 29 27 Determination of incident angle modifier (45 ) Test date [DD/MM/YYYY] 17/04/2017 to 27/04/2017 Method used for determination acc. to Clause 27.1.4 Quasi dynamic Latitude [ ] 50.92 N Longitude [ ] 6.99 E Collector azimuth angle [ from south] 0 (fixed) and tracked Collector tilt angle [ from horizontal] 45 and 20 Orientation of absorber tubes vertical Used fluid Water Mean mass flow [kg/s] 0.047 Incidence angle modifier Angle [ ] 10 20 30 40 50 60 70 80 K b longi [ ] 1.00 1.00 1.00 0.99 0.99 0.98 0.96 0.90 K b trans [ ] 1.00 1.02 1.01 1.03 1.03 1.06 0.98 0.78 Collector performance coefficients Sample No. Incidence angle modifier K b (40.2 /40.2 ) [ ] Kd 1.021 0.917 (measured) 20170002987 Maximum power peak (at 1000 W/m² (G b = 850 W/m², G d = 150 W/m²)) 1202 Gross area [m²] based on 2.360 (+/- Standard deviation) eta0 beam 0.516 c3 - - - kd 0.917 c4 - - - b0 0.022 c5 10.782 c1* 1.088 c6 - - - c2* 0.006 - Supplementary information: * adapted from indoor measurement (45 )

Seite 19 von 29 Page 19 of 29 27 Determination of incident angle modifier (3 ) Test date [DD/MM/YYYY] 17/04/2017 to 27/04/2017 Method used for determination acc. to Latitude [ ] Longitude [ ] Collector azimuth angle [ from south] Clause 27.1.4 Quasi dynamic 50.92 N 6.99 E 0 (fixed) and tracked Collector tilt angle [ from horizontal] 45 and 20 Orientation of absorber tubes Used fluid vertical Water Mean mass flow [kg/s] 0.047 Supplementary information: Incidence angle modifier Angle [ ] 10 20 30 40 50 60 70 80 K b longi [ ] 1.00 1.00 1.00 0.99 0.99 0.98 0.96 0.90 K b trans [ ] 1.00 1.02 1.01 1.03 1.03 1.06 0.98 0.78 Supplementary information: * in case of horizontal tube orientation the IAM-values of trans and longi must be switched Collector performance coefficients Sample No. Incidence angle modifier K b (40.2 /40.2 ) [ ] Kd 1.021 0.917 (measured) 20170002987 Maximum power peak (at 1000 W/m² (G b = 850 W/m², G d = 150 W/m²)) based on 1202 Gross area [m²] 2.360 (+/- Standard deviation) eta0 beam 0.516 c3 - - - kd 0.917 c4 - - - b0 0.021 c5 10.777 c1* 1.158 c6 - - - c2* 0.005 - Supplementary information: * adapted from indoor measurement (3 ) For final evaluated collector performance results see Final performance evaluation.

Seite 20 von 29 Page 20 of 29 28 Determination of the pressure drop across a collector Test date [DD/MM/YYYY] 02/06/2017 Used fluid Water Average fluid temperature [ C] 15.9 Collector tilt angle [ from horizontal] 90 Function of pressure drop curve related to: {dp(m dot )=} with x [kg/s] and y [kpa] y = 4.155e +02 x 2 + 1.590e +01 x {dp(v dot )=} with x [l/h] and y [kpa] y = 3.206e -05 x 2 + 4.418-03 x Sample No. 20170002988 1 st Flow rate [kg/s] 0.0219 0.0378 0.0519 0.0875 0.1711 1 st Flow rate [l/h] 79 136 187 315 616 1 st Pressure drop kpa 0.44 1.12 1.9 4.7 14.9 2 nd Flow rate [kg/s] 0.0261 0.0422 0.0533 0.0908 0.1722 2 nd Flow rate [l/h] 94 152 192 327 620 2 nd Pressure drop kpa 0.58 1.35 2.01 5.01 15

Seite 21 von 29 Page 21 of 29 - Final performance evaluation Final evaluated collector performance coefficients (45 ) based on Gross area [m²] Aperture area [m²] Absorber area [m²] 2.360 1.600 1.510 (+/- Standard deviation) eta0 hem * 0.510 (calculated) 0.752 (calculated) 0.796 (calculated) eta0 beam ** 0.516 0.761 0.806 a 1 1.178 1.738 1.841 a 2 0.005 0.008 0.008 Maximum power peak (at G * = 1000 W/m²)* Kd ** 1202 0.917 Supplementary information: 45 inclination angle * at 1000 W/m² (G b = 850 W/m², G d = 150 W/m²) ** based on outdoor results

Seite 22 von 29 Page 22 of 29 Collector power output record [W] (45 ) Tm Ta [K] at 400 W/m² (G b = 200 W/m², G d = 200 W/m²) at 700 W/m² (G b = 440 W/m², G d = 260 W/m²) at 1000 W/m² (G b = 850 W/m², G d = 150 W/m²) 0 467 826 1202 10 440 799 1175 20 410 769 1145 30 377 736 1112 40 341 701 1077 50 303 662 1038 60 262 621 997 70 218 577 953 80 171 530 906 90 121 480 856 100 68 428 804 Supplementary information: 45 inclination angle Collector power output Supplementary information: 45 inclination angle

Seite 23 von 29 Page 23 of 29 Final evaluated collector performance coefficients (3 ) based on Gross area [m²] Aperture area [m²] Absorber area [m²] 2.360 1.600 1.510 (+/- Standard deviation) eta0 hem * 0.504 (calculated) 0.743 (calculated) 0.7787 (calculated) eta0 beam ** 0.510 0.752 0.797 a 1 1.292 1.906 2.02 a 2 0.004 0.006 0.006 Maximum power peak (at G * = 1000 W/m²)* Kd ** 1189 0.917 Supplementary information: 3 inclination angle * at 1000 W/m² (G b = 850 W/m², G d = 150 W/m²) ** based on outdoor results; corrected by indoor comparison between 45 and 3 incident angle measurement

Seite 24 von 29 Page 24 of 29 Collector power output record [W] (3 ) Tm Ta [K] at 400 W/m² (G b = 200 W/m², G d = 200 W/m²) at 700 W/m² (G b = 440 W/m², G d = 260 W/m²) at 1000 W/m² (G b = 850 W/m², G d = 150 W/m²) 0 461 817 1189 10 433 788 1160 20 402 757 1129 30 369 724 1096 40 333 688 1060 50 295 650 1022 60 255 610 982 70 212 567 939 80 167 522 894 90 120 475 847 100 70 425 797 Supplementary information: 3 inclination angle Collector power output Supplementary information: 3 inclination angle

Seite 25 von 29 Page 25 of 29 - General remarks and subblementary information Measuring uncertainties All results only refer to the test samples that were subjected to testing. The extended total measuring uncertainty for the outdoor performance test is: 2.8 % (for irradiation levels above 700 W/m²) The extended total measuring uncertainty (k=2) for the indoor performance test is: 2 % Collector efficiency parameters according to ErP-Lot 1 (45 ) Eta col(0.04/1000) 0.674 (A aperture ) /// 0.457 (A gross ) Collector efficiency parameters according to ErP-Lot 1 (3 ) Eta col(0.04/1000) 0.664 (A aperture ) /// 0.450 (A gross ) based on Add information to collector efficiency acc. to SRCC (45 ) Collector performance coefficients based on gross area and inlet temperature Gross area [m²] 2.360 (+/- Standard deviation) eta0 hem * 0.506 a 1 1.194 (+/- 0.019) a 2 0.005 (+/- 0.000) Supplementary information: * at 1000 W/m² (G b = 850 W/m², G d = 150 W/m²) Add information to collector efficiency acc. to SRCC (3 ) Collector performance coefficients based on gross area and inlet temperature Gross area [m²] based on 2.360 (+/- Standard deviation) eta0 hem * 0.498 a 1 1.302 (+/- 0.007) a 2 0.004 (+/- 0.000) Supplementary information: * at 1000 W/m² (G b = 850 W/m², G d = 150 W/m²)

Seite 26 von 29 Page 26 of 29 - Additional normative information Collector performance table 45 inclination angle Date UTC G t a U m dot t in t e t m t m-t a T*m Q dot eta g YY-MM-DD hh:mm W/m² C m/s kg/s C C C K m²*k/w W - - - 2017-04-11 18:07 852 25.91 3.3 0.0467 24.53 29.74 27.13 1.22 0.00143 1019 0.507 2017-04-11 18:17 852 25.50 3.3 0.0467 24.48 29.69 27.09 1.59 0.00187 1018 0.506 2017-04-11 17:11 852 25.62 3.3 0.0479 43.61 48.41 46.01 20.40 0.02394 962 0.478 2017-04-11 17:21 852 26.11 3.3 0.0479 43.61 48.40 46.00 19.90 0.02335 961 0.478 2017-04-11 16:30 852 26.05 3.3 0.0473 71.89 76.21 74.05 48.00 0.05634 860 0.428 2017-04-11 16:40 852 26.16 3.3 0.0473 71.89 76.22 74.06 47.90 0.05622 860 0.428 2017-04-11 15:50 852 26.43 3.3 0.0470 90.80 94.75 92.78 66.34 0.07787 781 0.389 2017-04-11 16:00 852 25.97 3.3 0.0470 90.84 94.79 92.81 66.85 0.07846 783 0.389 Supplementary information: 45 inclination angle Collector performance table 3 inclination angle Date UTC G t a U m dot t in t e t m t m-t a T*m Q dot eta g YY-MM-DD hh:mm W/m² C m/s kg/s C C C K m²*k/w W - - - 2017-04-11 12:34 852 26.40 3.3 0.0474 24.55 29.63 27.09 0.70 0.00082 1008 0.501 2017-04-11 12:44 852 26.49 3.3 0.0471 24.54 29.65 27.10 0.61 0.00071 1006 0.501 2017-04-11 11:39 852 26.14 3.3 0.0481 43.44 48.13 45.79 19.64 0.02306 946 0.470 2017-04-11 11:49 852 26.26 3.3 0.0480 43.44 48.15 45.80 19.54 0.02294 945 0.470 2017-04-11 10:52 852 26.13 3.3 0.0472 71.56 75.81 73.69 47.56 0.05582 842 0.419 2017-04-11 11:02 852 26.01 3.3 0.0472 71.55 75.80 73.68 47.66 0.05594 842 0.419 2017-04-11 09:33 852 25.72 3.3 0.0472 90.55 94.38 92.46 66.74 0.07833 762 0.379 2017-04-11 09:43 852 25.78 3.3 0.0475 90.59 94.39 92.49 66.70 0.07829 762 0.379 Supplementary information: 3 inclination angle

Seite 27 von 29 Page 27 of 29 Incident angle modifier Measured and simulated power during incidence angel determination

Seite 28 von 29 Page 28 of 29 Climate data Date G total day T mean day T min day T max day h > 1000 W/20 C T mean 1000 W T min 1000 W T max 1000 W ddmmyyyy MJ C C C h C C C 22.02.2017 0.72 10.1 9.1 11.2 0.00 - - - - - - - - - 23.02.2017 2.58 9.4 4.7 11.6 0.00 - - - - - - - - - 24.02.2017 14.53 6.3 2.2 11.1 0.00 - - - - - - - - - 25.02.2017 12.61 5.2-0.4 10.8 0.00 - - - - - - - - - 26.02.2017 7.79 10.0 6.2 15.1 0.00 - - - - - - - - - 27.02.2017 2.02 10.8 7.0 13.3 0.00 - - - - - - - - - 28.02.2017 9.44 6.2 3.3 10.8 0.00 - - - - - - - - - 01.03.2017 6.00 6.3 3.0 10.0 0.00 - - - - - - - - - 02.03.2017 3.85 8.2 5.0 10.2 0.00 - - - - - - - - - 03.03.2017 2.50 2.2 0.0 10.0 0.00 - - - - - - - - - 04.03.2017 0.00 0.0 0.0 0.0 0.00 - - - - - - - - - 05.03.2017 0.00 0.0 0.0 0.0 0.00 - - - - - - - - - 06.03.2017 0.00 0.0 0.0 0.0 0.00 - - - - - - - - - 07.03.2017 1.95 3.0 0.0 10.3 0.00 - - - - - - - - - 08.03.2017 1.35 5.3 2.4 9.8 0.00 - - - - - - - - - 09.03.2017 5.42 9.4 4.6 16.0 0.00 - - - - - - - - - 10.03.2017 17.71 8.6 5.4 16.7 0.00 - - - - - - - - - 11.03.2017 14.56 9.9 4.6 18.0 0.00 - - - - - - - - - 12.03.2017 20.00 10.3 4.8 18.2 0.00 - - - - - - - - - 13.03.2017 17.08 10.3 3.8 18.5 0.00 - - - - - - - - - 14.03.2017 14.98 11.7 6.3 19.4 0.00 - - - - - - - - - 15.03.2017 11.38 12.3 6.4 19.8 0.00 - - - - - - - - - 16.03.2017 20.88 11.4 2.8 22.0 0.00 - - - - - - - - - 17.03.2017 4.64 10.0 6.5 13.5 0.00 - - - - - - - - - 18.03.2017 2.50 9.5 5.2 12.7 0.00 - - - - - - - - - 19.03.2017 4.58 12.1 9.4 15.8 0.00 - - - - - - - - - 20.03.2017 6.80 11.9 9.1 15.3 0.00 - - - - - - - - - 21.03.2017 4.98 9.5 3.6 12.3 0.00 - - - - - - - - - 22.03.2017 13.24 7.3 0.5 13.4 0.00 - - - - - - - - - 23.03.2017 21.02 11.5 3.4 21.1 0.00 - - - - - - - - - Supplementary information: Exposure values for performance and rest of reliability test; continued on next page; Colour code: not part of exposure ; indoor exposure time (not valid) ; outdoor exposure time (valid)

Seite 29 von 29 Page 29 of 29 Climate data Date G total day T mean day T min day T max day h > 1000 W/20 C T mean 1000 W T min 1000 W T max 1000 W ddmmyyyy MJ C C C h C C C 24.03.2017 19.10 11.3 5.0 20.9 0.00 - - - - - - - - - 25.03.2017 21.68 11.4 2.9 20.4 0.00 - - - - - - - - - 26.03.2017 21.08 13.1 5.3 22.0 0.00 - - - - - - - - - 27.03.2017 24.67 12.9 5.3 22.2 0.00 - - - - - - - - - 28.03.2017 22.30 15.1 5.5 26.5 0.00 - - - - - - - - - 29.03.2017 8.85 14.1 8.9 19.7 0.00 - - - - - - - - - 30.03.2017 16.07 17.5 11.2 26.0 0.00 - - - - - - - - - 31.03.2017 19.04 18.1 11.7 25.7 0.00 - - - - - - - - - 01.04.2017 9.63 14.8 10.1 21.9 0.00 - - - - - - - - - 02.04.2017 17.04 14.2 8.4 21.6 0.00 - - - - - - - - - 03.04.2017 4.09 11.6 4.9 22.1 0.00 - - - - - - - - - 04.04.2017 0.00 12.0 3.7 21.5 0.00 - - - - - - - - - 05.04.2017 10.02 10.2 3.9 16.3 0.00 - - - - - - - - - 06.04.2017 9.62 9.5 6.3 15.9 0.00 - - - - - - - - - 07.04.2017 5.91 10.9 6.2 16.1 0.00 - - - - - - - - - 08.04.2017 16.34 14.0 9.6 22.3 0.00 - - - - - - - - - Supplementary information: Exposure values for performance and rest of reliability test; Colour code: not part of exposure ; indoor exposure time (not valid) ; outdoor exposure time (valid)