UV Hound Series. Air Monitoring Where You Need it When You Need It, How You Need It. Portable UVDOAS Mul gas Analyzers. Multi-Gas Capability

Similar documents
UV Hound Series. Dependable High Quality Air Monitoring. Accurate Readings Within Seconds. Portable UVDOAS Multi-gas Analyzers. Multi-Gas Capability

UV3000. Accurate, precise, and portable ambient gas point analyzer

Assessing Unknown Odors and Chemicals

Robert Crampton Ph.D Brent Olive PH.D, Don Gamelis PH.D. Argos Scien7fic

RS DYNAMICS ECOPROBE 5. Portable IR/PID Gas Analyzer PID. PID and IR Analyzers

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

Questions, Myths and Misconceptions about Using Photoionization Detectors

White Paper. Overview: NDIR Definition:

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

The Claviature of Gas Analysis

UV Quality Assurance. Dark Current Correction

Sampling for Gases and Vapors

ISA QATAR : 90 th Seminar

2B Technologies, Inc. An InDevR Company

Smart Sensing Embedded Spectroscopy Platform Botlek studiegroep 06-april-2017

Bridging the gap summer work booklet. Bridging the Gap

VALIDATION STUDY OF FTIR-BASED EMISSIONS MEASUREMENTS AT A MUNICIPAL WASTE COMBUSTOR

Agilent G2350A Atomic Emission Detector (AED)

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

Cantilever enhanced tunable diode laser photoacoustic spectroscopy in gas purity measurement case study: acetylene in ethylene

2Fe 2 O 3 +3H 2 S FeS+FeS x +S+3H 2 O

Monomer Analysis. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

SIFT-MS. technology overview

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer

Extrel is widely respected for the quality of mass spectrometer systems that are

Ecocat. HD-VOC Catalysts

Fourier Transform Infrared Spectroscopy Postlab Last modified: June 17, 2014

WEATHER STATION FOR SOLAR FARM MONITORING

Time Series. Knowledge Discovery and Data Mining 2 (VU) ( ) Roman Kern. ISDS, TU Graz

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

Combustible Gas Catalytic Bead (0-100 %LEL) Part No FM Performance Certified 1,4 FM Performance Certified 1

Using 11.7eV PID Lamps To Accurately Measure VOCs With Ionization Energy Above 10.6eV

Far UV Absorbance Detector


Chemical Radiological & Explosive. Detection Solutions for First Responders

Semi-continuous Benzene Monitoring in Burlington, Vermont July 2007-June 2008

Alphasense Ltd. Compliance Statements and Certificates. Contents. The Restriction of the Use of Certain Hazardous Substances (RoHS)...

VUV ANALYTICS VGA-100 GC DETECTOR Gas Chromatograph Agilent 6890 equipped with a 7683 model autosampler Restek 30m x 0.25mm x 0.

IV. DIRECT MEASUREMENT LABS. Introduction

FTIR measurement of NH 3, HCN, SO 2, H 2 S and COS in pulverized lignite oxy-fuel flames Daniel Fleig, Stefan Hjärtstam and Daniel Kühnemuth

Technical/Application Article 01 Version 1.2

Determine the Inside Wall Temperature of DSTs using an Infrared Temperature Sensor

The DialPath Solution an Easier Way to Analyze Liquids By FTIR. Yanqia Wang, Ph.D. Application Engineer - FTIR Agilent Technologies May 7, 2015

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

Introduc on to Choosing a Kriging Plan

Application Note S/SL

Petrochemical. Transformer Oil Gas Analysis - TOGA

Understanding catalytic LEL combustible gas sensor performance

Monthly Report: Chevron Richmond Community Air Monitoring Program. Report Number: RCAMP_MO_11 Date: February RCAMP_MO_11 Page 1 of 26

Catalytic bead sensors are used primarily to detect

Vaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance

Reprinted from February Hydrocarbon

Slide 1. Slide 2. Slide 3. Choosing and Using the Best Sensor Technologies for Marine Chemistry Applications

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

Minimum (-31) every 10 s -35 (-31)

Earthquake Detec-on and Loca-on using Cascadia Ini-a-ve data. Susan L. Bilek and Emily Morton Earth and Environmental Science Dept.

AWM3000 Series Mass flow sensor for gases

Balancing chemical reaction equations (stoichiometry)

Real-time ppb CO 2 Impurity Detection by an Advanced FTIR- UVF System

Choosing the best detection technologies for measuring combustible gas and VOC vapors

Monthly Report: Chevron Richmond Community Air Monitoring Program. Report Number: RCAMP_MO_5 Date: August RCAMP_MO_5 Page 1 of 26

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

REHADALI TECHNOLOGY FM

High-Speed Gas and Headspace Analysis for the Process-Line and Laboratory: SIFT- MS IFPAC 2017

MEASURING H 2 S IN CRUDE OIL FOR QUALITY CONTROL & TRANSPORTATION SAFETY

Simple Use Compact and Robust Fast and Efficient

Measurement Technique and its Application to Trace Components of Atmospheric Gas

PIN Silicon Photodiode OP950 Series

2681 Parleys Way Suite 201 Salt Lake City, UT AccuSense Value Proposition

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

ASTORIA PACIFIC. Automated Wet-Chemistry Analyzers and Diagnostic Reagents. rapid-t

SkyScan EWS-PRO - Manual -

Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:

Non-Acoustical Inputs

Scalable Compu-ng Challenges in Ensemble Data Assimila-on. FRCRC Symposium Nancy Collins NCAR - IMAGe/DAReS 14 Aug 2013

Understanding ammonia sensors and their applications

CH4 CO2 NH3 SO2 SUBSTANCE LIST. further substances and detection limits on request. January 2018

SMCJ5.0~440(C)A. MAXIMUM RATINGS AND CHARACTERISTICS Ra ngs at 25 C ambient temperature unless otherwise specified. THERMAL CONSIDERATIONS

Edgetech Instruments Inc.

S is referred to as sour. The sulfide loading lends an unpleasant odor and makes the water corrosive. Additionally, the presence of H 2

Real Time On-Site Odor and VOC Emission Measurements Using a znose

Hydrogen & Chlorine monitoring for the Chlor-Alkali Industry


Humidity Calibration Solutions

SKALAR. your partner in chemistry automation. Primacs SNC Total Carbon and Total Nitrogen Analyzer

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219

ONYX -MCE MULTI-CHANNEL OPTICAL FIBER PYROMETERS WITH ACTIVE EMISSIVITY COMPENSATION PRECISION TEMPERATURE MEASUREMENT FOR DEMANDING INDUSTRIAL

TECHNICAL DESCRIPTION SPECTRAFLOW ON LINE ANALYZER for BELT CONVEYOR APPLICATION

CALIOPE EU: Air Quality

WeatherHub2 Quick Start Guide

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

Owlstone Nanotech Inc

Introduction to Blackbody Sources

PIN Silicon Photodiode OP950 Series

Overview Brochure Comprehensive range of instrumentation for the measurement of moisture and oxygen

Humidity Calibration Solutions

ActiPix SDI300 Surface Dissolution Imaging System

Complete Moisture Analysis

Integrated Electricity Demand and Price Forecasting

Transcription:

UV Hound Series Portable UVDOAS Mul gas Analyzers Air Monitoring Where You Need it... With PPB level detec on limits and simultaneous mul gas capability you can say goodbye to measuring Total VOCs. Hound analyzers are the recognized choice for Industrial hygiene, leak detec on, Hazmat first response and portable air quality monitoring. Multi-Gas Capability Individual VOCs CONTACT: Beetslaan 93, 4707 JP, Roosendaal, Netherlands T: +31 (0) 16523 4444 PPB Sensitivity Integrated Networking Automated Reporting Configurable Alarms Cannot be Poisoned CONTACT: Cerex Monitoring Solu ons, LLC. 1816 Briarwood Industrial Court, Suite D Atlanta, GA. 30329 678 570 6662 www.cerexms.com Fully Portable...When You Need It, How You Need It.

Three Models to Choose From: Cerex Micro Hound, Mini Hound, and Hound Analyzers u lize the same core technology, differing in physical size and minimum detec on limits. All are portable, capable of con nuous air monitoring, and designed for years of service. Micro Hound FR: Our smallest Mini Hound FR: Our mid size Hound FR: Our largest and most sensi ve and most portable model. Is equipped with a sealed external USB (1) Port as well as two inter nal USB ports. Despite the small size, the Micro Hound s 2 meter sample path allows PPB level de tec ons of many gases. Weight is 27.5 pounds. model balances low detec on limits with excellent portability. This ana lyzer is equipped with sealed exter nal LAN (1), WAN (1) and USB (1) ports as well as two internal USB ports. This unit has an 8.5 meter sample path and weighs less than 33lbs. model. This analyzer is equipped with sealed external LAN (1), WAN (1) and USB (1) ports as well as two internal USB ports for simple installa on of USB peripheral devices such as cellular modem, GPS or streaming web cam era. This unit offers excellent detec on limits with a 17 meter sample path and is equipped with wheels for rolling transport: 38 Lbs. All Hound Series Analyzers Feature: Many of the features of the Hound analyzer series came as sugges ons by the fire fighters and hazmat first responders who spent over a year and half tes ng the Cerex Mini Hound in real world structure fires and hazmat first response applica ons. Hound Se ries Analyzers are equipped with an integrated touchscreen interface and computer running user familiar Windows opera ng system. With simple, intui ve controls and large bu ons, Hound analyzers are as easy to use as a PC or smartphone. Integrated WiFi makes remote access and control easy. Simply use a common VNC u lity for full remote access. Integrated Computer with Windows Inherent calibra on: No Bump Calibra on, Ever! Touchscreen Interface User configurable, mul ple, staged alarms Integrated WiFi Audible, Visual and Email alarm func onality.csv data file output User configurable acquisi on cycles Simultaneous mul gas detec on capabili es Unaffected by humidity Part per billion minimum detec on limits Cannot be Poisoned 1816 Briarwood Industrial Court, Suite D Atlanta, GA. 30329 678-570-6662 Windows is a registered trademark of Microso Corpora on in the United States and many other countries.

Cerex CMS So ware: Control is in your hands... All Cerex analyzers use Con nuous Monitoring So ware. CMS provides user interface, data logging and analy c gas detec on and quan fica on func onality. CMS puts control where it belongs, in your hands. Target gas concentra ons and alarm parameters are reported each user configured acquisi on cycle. Alarms, acquisi on me, background acquisi on, detectable gases, and detec on limits are all user configurable....from anywhere Deploying a Hound analyzer with internet access, or adding an op onal cellular USB modem adds powerful real me remote control and data access func onality. Alarms may be automa cally emailed to any email address when gas concentra ons exceed user configurable alarm thresholds, and data may be automa cally emailed daily. The analyzer may be controlled and monitored from any pc or smartphone with Internet access. The CMS Data tab displays per acquisi on gas concentra on, data validity and visual alarms. Single beam and absorp on plots are readily viewed in real me. Raw single beam data is always saved Trended concentra on data is available at a glance on the CMS Data Summary tab.

Detec on Capabili es Cerex UVDOAS Delivers What Other Technologies Cannot Unlike IR, NDIR, Electro chemical, PID, FID and GC/MS based detec on methods, Cerex UVDOAS delivers simultaneous monitoring of ppb levels of individual VOC species like Benzene, Toluene, Ethylbenzene, and Xylene in near real me. The method is unaffected by ambient humidity, requires no sample condi oning filter change prior to monitoring, requires no carrier gas, requires no wet chemistry, and incurs no analy c costs or sample handling costs. Results are immediate, and the raw data containing all the informa on necessary for gas iden fica on and quan fica on is always saved. UVDOAS Principle of Opera on Cerex Hound analyzers operate by sending a beam of UV light through the sample gas within the instrument. The UV beam is directed by a series of op cs to a high resolu on miniature spectrometer where the absorp on due to target gases is measured and recorded. A classical least squares regression analysis compares the measured absorp on spectrum to calibrated reference absorp on spectra files. Beer s law is then used to determine gas concentra ons per USEPA TO 16 Methodology. Hound series analyzers will detect many gases simultaneously at ppb concentra ons within complex mixtures. Some gases however, like hydrogen sulfide must be monitored individually. The presence of high concentra on interference species may obscure some gases or cause false posi ves under certain circumstances. Single Gas Minimum Detec on Limits Parameter HOUND MINI MICRO HOUND HOUND Units Ammonia (NH 3 ) MDL 12 24 100 ppb 1,3 Butadiene MDL 12 24 100 ppb Benzene MDL 16 31 134 ppb Carbon Disulfide MDL 12 24 100 ppb Chlorine (Cl 2 ) MDL 294 588 2500 ppb Ethyl Benzene MDL 18 35 150 ppb Formaldehyde MDL 188 376 1600 ppb Hydrogen Sulfide (H 2 S) MDL 29 59 250 ppb Mercury (Hg) MDL.001.002.01 ppb Naphthalene MDL 12 24 100 ppb Nitrogen Oxide (NO) MDL 17 34 146 ppb Nitrogen Dioxide (NO 2 ) MDL 238 475 2020 ppb Ozone (O 3 ) MDL 118 235 1000 ppb o xylene MDL 222 444 1885 ppb m xylene MDL 21 41 175 ppb p xylene MDL 14 28 119 ppb Styrene (C 8 H 8 ) MDL 36 71 300 ppb Sulfur Dioxide (SO 2 ) MDL 19 38 160 ppb Toluene MDL 49 99 419 ppb Accuracy (TYP) ±3 ±3 ±3 %FS Path Length 17.00 8.50 2.0 Meters The Cerex Hound series instruments are mul gas analyzers available with our standard calibrated gas reference files (Table on le ) to provide high sensi vity to mixtures of single gases in air. Individual gas species or aggregate concentra ons may be reported at the operator s discre on. Hound analyzers are designed to minimize opera onal costs and maximize up me. Only two consumable items: The UV source and air intake filter. Both are field replaceable in under fi een minutes. UV sources are warranted for 4000 hours of opera on. Actual life me typically exceeds 5000 hours. 1816 Briarwood Industrial Court, Suite D Atlanta, GA. 30329 678-570-6662

Op ons that make sense for real world air monitoring Powerful Communica on Features Internal and external USB ports make the addi on of op onal USB peripherals such as GPS, Cellular Modem or even a Streaming Webcam possible. This flexibility adds powerful real me monitoring, automated data repor ng and automated alarm repor ng func onality. Hound analyzers may be deployed and environmental condi ons monitored by onsite personnel as well as remote decision makers via any PC or smartphone with an internet connec on. Integrated Meteorological Monitoring Defini ve data support is available by ordering a Hound analyzer with integrated temperature and 3 D ultrasonic wind modeling hardware. All data parameters are integrated into CMS data tables, and the anemometer is tripod mounted for rapid deployment. External Ba ery Systems Hound analyzers u lize an internal lithium polymer ba ery and external smart charger for opera on. A variety of op onal external ba eries are available to extend con nuous monitoring capability to 17 hours in the absence of power without recharge. Addi onal Sensor Capabili es Up to five addi onal sensors may be added to the Hound, three to the Mini Hound and one to the Micro Hound to provide monitoring of gases not sensi ve to UVDOAS technology. Data from addi onal sensors is fully integrated into CMS and displayed per acquisi on cycle as well as integrated into CMS.csv data summary tables. Below is a table of commonly requested addi onal sensors. Addi onal sensors must be ordered at the me of manufacture, or the analyzer returned to Cerex for retro fit. CEREX UV HOUND Series Op onal Sensors Compound Technology TYP Life me Range LDL Accuracy T 90 Arsine (AsH3) Electrochemical 2 3 Years 0 1.5 PPM 2% FS ±5% FS 60 S Carbon Monoxide (CO) Electrochemical 2 3 Years 0 300 PPM 2% FS ±5% FS 30 S Carbon Dioxide (CO2) Infrared 5 + Years 0 5000 PPM 2% FS ±5% FS 30 S Hydrogen Cyanide (HCN) Electrochemical 2 3 Years 0 15 PPM 2% FS ±5% FS 60 S LEL (General Purpose) Cataly c 2 3 Years 0 100% LEL 2% FS ±5% FS 30 S Methane (CH4) Infrared 5 + Years 0 100% LEL 1% LEL ±5% FS 30 S Oxygen (O2) Galvanic Cell 2 3 Years 0 25% Vol 0.1% FS ±0.5% Vol 20 S Hydrogen Sulfide (H2S) Electrochemical 2 3 Years 0 100 PPM 2% FS ±5% FS 45 S Specifica ons and Dimensions CEREX HOUND Series Analyzer Dimensions 35.75" x 13.50" x 5.25" HOUND (90.8 x 34.3 x 13.3 cm) 38.5 Lbs 24.75" x 19.375" x 8. 75" MINI HOUND (61.6 x 49.22 x 22.23) 32.8 Lbs 22 x 17.75 x 5 MICRO HOUND (55.9 x 45.1 x 12.7 cm) 27.5 Lbs CEREX HOUND Series Analyzer Specifica ons Input Voltage 100VAC to 240VAC, Single Phase 47 63Hz Input Current 4A Max Opera ng Ambient Temperature 0 to +45ºC Storage Temperature 10 to 60 ºC Opera ng and Storage Humidity 0 99% Lamp Life 4000 Hour Manufacturer Warranty Internal Ba ery Life (TYP) 3.5 Hours, op onally to 17.5 Hours Spectral Range 195nm to 400nm* Spectral Resolu on 0.05nm 0.20nm* Intake Par culate Filter 5 Micron OR op onal HEPA 0.3 Micron Sample Intake Rate 7.9 CFM (3.5 CFM HEPA Filter) Probe Length 3 meters, with quick connect fi ng *Dependent upon spectrometer installed.

TO 16 Methodology Currently there are a number of defini ons of detec on limits used to characterize the performance of air monitoring systems. A common defini on of is the magnitude of the absorbance spectra that is twice the system noise. The U.S. Environmental Protec on Agency s Compendium of Methods for the Determina on of Toxic Organic Compounds in Ambient Air Second Edi on Compendium Method TO 16 Long Path Open Path Fourier Transform Infrared Monitoring Of Atmospheric Gases defines detec on limits as the following: The detec on limit of the Hound system is a dynamic quan ty that will change as the atmospheric condi ons change. The variability of the target gas, and all of the other interfering species concentra ons contributes to the variability of this measurement. The detec on limit as determined in this procedure is the result of a calcula on using a set of 15 individual absorp on spectra. The 16 individual single beam spectra used for this determina on are acquired in 5 min intervals and no me is allowed to elapse between them. The absorp on spectra are then created by using the first and the second single beam spectra, the second and the third, and the third and the fourth, and so on un l the 15 absorp on spectra are obtained. These absorp on spectra are analyzed in exactly the same way that all field spectra are to be analyzed and over the same wave number region. The analysis should result in a set of numbers that are very close to zero because most of the effects of the gas variability have been removed. The numerical results should be both posi ve and nega ve and for a very large set of data should average to zero. Three mes the standard devia on of this calculated set of concentra ons is defined to be the detec on limit. Although Method TO 16 was wri en for open path FTIR, the Cerex Hound system is unique among UV systems in that the raw data is essen ally iden cal to an FTIR Single beam file. Hence the direct correla on drawn to TO 16. Using the detec on limit defini on described in TO 16, CEREX developed the detec on limits that are listed here. It should be noted that the actual detec on limits achieved in the field will vary. This is primarily due to the fact that varia ons in interfering species will result in variability in detec on limits. Cerex considers the detec on limits listed to be a very conserva ve es mate. The end user of the equipment will likely achieve much be er results in the field. Cerex believes it is a good policy to not oversell a capability to our poten al customers. Minimal maintenance The only consumables are the UV source and intake filter. Cannot be poisoned Individual gas species detec on Data and alarms can automa cally be sent to email addresses, website or control room. Inherent calibra on No ongoing calibra on required, No Bump Calibra on User configurable autobackground func onality User configurable alarms Fail to safe opera on Cerex manufactures a full line of UVDOAS and FTIR Mul gas Analyzer products for CEMs, Process Monitoring, PAAM, Leak detec on, Zone Monitoring, and Indoor Air Quality Monitoring as well as custom analyzers for specific monitoring needs. Contact us for a demonstra on of our technology. +1 678 570 6662 CONTACT: Beetslaan 93, 4707 JP, Roosendaal, Netherlands T: +31 (0) 16523 4444