Comparison of discharge measurements - Thermodynamic to US Clamp- On, stationary US and Needle Opening Curve

Similar documents
Comparison of discharge measurements -

ENERGY DISTRIBUTION ANALYSIS IN A LOW HEAD FRANCIS TURBINE DURING THERMODYNAMIC EFFICIENCY MEASUREMENTS

Chapter Four fluid flow mass, energy, Bernoulli and momentum

THE PRESSURE-TIME MEASUREMENTS PROJECT AT LTU AND NTNU

ME 316: Thermofluids Laboratory

UNCERTAINTIES FOR PRESSURE-TIME EFFICIENCY MEASUREMENTS

Investigation of Flow Profile in Open Channels using CFD

To investigate the performance of the Pelton Wheel turbine with different range of flow rates and rotational speeds.

ANALYSIS OF NATURAL FREQUENCIES OF DISC-LIKE STRUCTURES IN WATER ENVIRONMENT BY COUPLED FLUID-STRUCTURE-INTERACTION SIMULATION

Objectives. Conservation of mass principle: Mass Equation The Bernoulli equation Conservation of energy principle: Energy equation

ISO 9906 INTERNATIONAL STANDARD. Rotodynamic pumps Hydraulic performance acceptance tests Grades 1 and 2

Unified Quiz: Thermodynamics

Feasibility study of the cascading mass ow rate evaluation as a new variant of Gibson's method

INTERNATIONAL STANDARD

Chapter Four Hydraulic Machines

Open channel discharge measurement using the acoustic transit time method a case study

HYDRAULIC TURBINES. Hydraulics and Hydraulic Machines

Application of an ultrasonic velocity profile monitor in a hydraulic laboratory

FIELD TEST OF WATER-STEAM SEPARATORS FOR THE DSG PROCESS

COURSE NUMBER: ME 321 Fluid Mechanics I 3 credit hour. Basic Equations in fluid Dynamics

Homework 6. Solution 1. r ( V jet sin( θ) + ω r) ( ρ Q r) Vjet

ScienceDirect Abstract

vector H. If O is the point about which moments are desired, the angular moment about O is given:

Applied Fluid Mechanics

Applied Fluid Mechanics

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

Two mark questions and answers UNIT I BASIC CONCEPT AND FIRST LAW SVCET

Introduction to Turbomachinery

Instruction Manual. Equipment for Engineering Education

nozzle which is fitted to a pipe through which the liquid is flowing under pressure.

SUMMER 14 EXAMINATION

An Essential Requirement in CV Based Industrial Appliances.

INTERNATIONAL OIML D 25 DOCUMENT. Vortex meters used in measuring systems for fluids ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

Compressible Gas Flow

Numerical and Experimental Study of Effects of Upstream Disturbance on Accuracy of Vortex-Shedding Flow Meter

1 st Law Analysis of Control Volume (open system) Chapter 6

MECA-H-402: Turbomachinery course Axial compressors

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Applied Fluid Mechanics

PUMP PERFORMANCE MEASUREMENTS Jacques Chaurette p. eng. April 2003

CHAPTER 5 MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES

SEM-2016(03)-II MECHANICAL ENGINEERING. Paper -11. Please read each of the following instructions carefully before. attempting questions.

Experiment (4): Flow measurement

CHAPTER (13) FLOW MEASUREMENTS

White Paper FINAL REPORT AN EVALUATION OF THE HYDRODYNAMICS MECHANISMS WHICH DRIVE THE PERFORMANCE OF THE WESTFALL STATIC MIXER.

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

Flow Measurement in Pipes and Ducts COURSE CONTENT

Hydraulic Turbines. Table 6.1 Parameters of hydraulic turbines. Power P (kw) Speed N (rpm)

FLUID MECHANICS D203 SAE SOLUTIONS TUTORIAL 2 APPLICATIONS OF BERNOULLI SELF ASSESSMENT EXERCISE 1

Chapter Four Hydraulic Machines

Introduction to Fluid Machines and Compressible Flow Prof. S. K. Som Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

Jet Aircraft Propulsion Prof. Bhaskar Roy Prof A M Pradeep Department of Aerospace Engineering Indian Institute of Technology, Bombay

NORTH SEA FLOW MEASUREMENT WORKSHOP 2004 In. St Andrews, Scotland

ALASTAIR MCLACHLAN Applications Cameron

TOTAL HEAD, N.P.S.H. AND OTHER CALCULATION EXAMPLES Jacques Chaurette p. eng., June 2003

Introduction to Chemical Engineering Thermodynamics. Chapter 7. KFUPM Housam Binous CHE 303

ME332 FLUID MECHANICS LABORATORY (PART II)

Chapter 7 The Energy Equation

Flowmeter Discharge Coefficient Estimation

Hydroelectric Design

Experimental Investigations on the Local Distribution of wall static pressure coefficient Due To an Impinging Slot Air Jet on a Confined Rough Surface

BME-A PREVIOUS YEAR QUESTIONS

Overload Surge Investigation Using CFD Data

Consideration of the pulsation as a design criterion for a newly developed oil-injected process gas screw compressor

Experiment No.4: Flow through Venturi meter. Background and Theory

DESIGN AND PERFORMANCE OF THE CONVERGING-DIVERGING VORTEX FLOWMETER

first law of ThermodyNamics

ENGINEERING FLUID MECHANICS. CHAPTER 1 Properties of Fluids

Nodalization. The student should be able to develop, with justification, a node-link diagram given a thermalhydraulic system.

M E 320 Professor John M. Cimbala Lecture 23

CVE 372 HYDROMECHANICS EXERCISE PROBLEMS

Efficient runner safety assessment during early design phase and root cause analysis

Centrifugal pumps - characteristics

LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS

FLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560

EFFECT OF FLOW DISTURBANCE ON MULTI-PATH ULTRASONIC FLOWMETERS

Introduction to Fluid Machines, and Compressible Flow Prof. S. K. Som Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

The influence of disc friction losses and labyrinth losses on efficiency of high head Francis turbine

Thermodynamics ENGR360-MEP112 LECTURE 7

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

INTERNATIONAL STANDARD

9. Pumps (compressors & turbines) Partly based on Chapter 10 of the De Nevers textbook.

Rigorous calculation of LNG flow reliefs using the GERG-2004 equation of state

Introduction to Fluid Machines and Compressible Flow Prof. S. K. Som Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

Where F1 is the force and dl1 is the infinitesimal displacement, but F1 = p1a1

(Refer Slide Time: 0:55)

For example an empty bucket weighs 2.0kg. After 7 seconds of collecting water the bucket weighs 8.0kg, then:

Flow Measurement in Pipes and Ducts COURSE CONTENT

EFFECT OF DISTRIBUTION OF VOLUMETRIC HEAT GENERATION ON MODERATOR TEMPERATURE DISTRIBUTION

UNIFIED ENGINEERING Fall 2003 Ian A. Waitz

Contents. 2 Basic Components Aerofoils Force Generation Performance Parameters xvii

NUMERICAL AND EXPERIMENTAL INVESTIGATION OF THE TEMPERATURE DISTRIBUTION INSIDE OIL-COOLED TRANSFORMER WINDINGS

Evaluation of the Effect of Relative Humidity of Air on the Coefficients of Critical Flow Venturi Nozzles

Chapter 5: Mass, Bernoulli, and Energy Equations

Flow Measurement in Pipes and Ducts

ME332 FLUID MECHANICS LABORATORY (PART I)

close to performances of the turbine gas meters designed for custody transfer measurements.

Mechanical Engineering for Renewable Energy Systems. Wind Turbines

Head loss coefficient through sharp-edged orifices

Transcription:

IGHEM 2012 The 9 th International conference on hydraulic efficiency measurements Trondheim, Norway June 27 th - 30 th, 2012 XXXXXX Comparison of discharge measurements - Thermodynamic to US Clamp- On, stationary US and Needle Opening Curve Tobias Rau, Marco Eissner Voith Hydro Holding GmbH & Co. KG Alexanderstr. 11, 89522 Heidenheim, GERMANY Abstract For high head hydro turbines the thermodynamic method is the most common way to measure the efficiency. This method uses the conversion of energy and enables to derive the discharge from its results. Other methods measure the discharge directly to verify the turbine efficiency at a hydroelectric unit. According to the IEC code 60041 the thermodynamic method is a primary method and therefore it will be taken as a reference in this paper for the comparison with three other methods of discharge measurement: a stationary ultrasonic device installed in front of the spherical valve and an ultrasonic clamp-on system between spherical valve and distributor inlet. In addition the needle opening of the six nozzles are used for the determination of the discharge. All the measurement methods are performed at a six nozzle vertical Pelton turbine with a head of approximately 500m. Thus every measurement method has the same boundary conditions and can be compared with each other. All the described methods, compared with the thermodynamic method, are according to IEC code 60041 secondary methods and can be used only for relative efficiency tests. The results of this test show besides the accuracy of these methods also their limitations. Partly the results correlate very well with those of the thermodynamic method. The ultrasonic clamp-on system had higher deviations mainly in the lower load part, maybe caused by a not optimal measuring position. The data of the stationary ultrasonic and the needle opening are very similar in comparison to the primary method. 1 Introduction Finding solutions of doing more cost effective relative efficiency tests it becomes essential to acquire more experience with different kind of discharge measurements. Especially compared to absolute methods accepted by IEC code 60041, e.g. the thermodynamic method. Within the last years the technical progress comes up to a point, where it is possible to measure discharges quickly with clamp on devices for temporarily installation.

This paper shall give a better understanding and shall spread the experience made with different kind of discharge measurement techniques and shall also show their limitations of use by comparing these results to the results of a thermodynamic efficiency test. In this paper the results of the thermodynamic efficiency test shall be the reference to all other methods which are described and applied. 2 Theoretical background 2.1 Thermodynamic The thermodynamic method results from the application of the conversation of energy. It is a transfer of energy between the machine and the water passing through it. The hydraulic efficiency (equation 4) of a turbine is defined as the ratio between the specific mechanical energy (equation 1) and the specific hydraulic energy (equation 2). This method gives the possibility to determine directly the energy that the water transmits to the turbine shaft. Beginning from the inlet reference section derived from the measured quantities and from the thermodynamic properties of water. This energy is called specific mechanical energy. The specific mechanical energy s unit is Joule per kg water. To measure all necessary quantities in practice a small portion of water will be extracted out of the main flow of the turbine into so called vessels. For the application of the thermodynamic method three different procedures can be used: Full expanded fluid (pressure term disappear) Partial expanded fluid (temperature term disappear) Not expanded fluid (measured quantities similar to the values in the main flow) These days the method of full expansion and partial expansion usually is not used any more. E m = a 2 2 v11 v21 ( p11 p21) + c p * T + + g * ( z11 z )[ J / Kg] 2 * 21 equation 1 General definition of specific mechanical energy 2 2 p p2 v1 v2 E = 1 + + g *( z1 z2)[ J / ] ρ 2 Kg equation 2 General definition of specific hydraulic energy H = E / g[ m] equation 3 Net head where a p 11 p 21 η h = E m E [%] equation 4 Hydraulic efficiency isothermal factor of water pressure in the vessel on the high pressure side pressure in the vessel on the low pressure side

cp T v 11 v 21 g z 11 z 21 p 1 p 2 ρ v 1 v 2 z 1 z 2 the specific heat capacity of water the differential temperature between high and low pressure side the velocity in the vessel on the high pressure side the velocity in the vessel on the low pressure side the acceleration due to gravity the level of the vessel on the high pressure side the level of the vessel on the low pressure side the pressure in the reference section on the high pressure side the pressure in the reference section on the low pressure side the density of water the velocity in the reference section on the high pressure side the velocity in the reference section on the low pressure side the level of the reference section on the high pressure side the level of the reference section on the low pressure side Figure 1 Schematic arrangement of measuring points for the thermodynamic method Figure 1 shows the schematic arrangement of the measuring points for the thermodynamic method at a vertical Pelton machine which was applied for this comparison. On the high pressure side the water was extracted with two sampling probes and taken into vessels. In both vessels the pressure, the temperature and the amount of extracted water was measured separately for the determination of the specific mechanical energy. In the penstock at high pressure side the inlet pressure was measured as an average of four pressure taps. On the low pressure side a measuring frame was installed with nine temperature sensors and two level probes. With this set up the energy distribution can be determined with a good resolution and accuracy. The measuring frame was installed in a distance of app. 8 x D that means the minimum distance recommended by IEC60041 was met.

By indirect determination of the mechanical power and the determination of specific mechanic energy the discharge through the machine can be calculated. 2.2 Stationary Ultrasonic U System The acoustic method of discharge measurement (ultrasonic, time of flight or transit time) is predicated on the propagation of velocity of an acoustic signal and the main flow velocity is vectorial summed. An acoustic signal sent downstream travels at a faster absolute velocity than an acoustic signal sent upstream. By measuring the travel times in both directions it is possible to determine the average axial velocity of the acoustic path crossing a certain cross section. where D L wi w i v axi n φ Q = D n 2 i= 1 w i * v _ axi * L wi * sinϕ equation 5 General equation for discharge according to transit time method [1] penstock diameter the length of the acoustic path the weighting coefficients the averaged axial flow velocity the number of acoustic paths in one plane the angle of the acoustic paths The stationary ultrasonic system was installed to detect the leakage in the penstock (see figure 2), e.g. in case of penstock rupture. It measures continuously the flow rate in the 2 penstocks and in the 4 inlet pipes to each turbine. Each penstock and the two corresponding inlet pipes will be compared continuously. The flow rates are measured with an ultrasonic transit-time measurement device on each line. For the comparison test the result of the section before the main inlet valve was used to measure the discharge by acoustic transit time method. The scope of this installation was not the measurement of efficiencies or performance guarantees.

Figure 2 Single Line Diagram of leakage monitoring ing [2] Figure 3 shows the arrangement of the acoustic paths before main inlet valve. In general the arrangement is dependent on the flow profile and the pipe diameter. For this project an arrangement of four planes with four paths was installed. 4 plane arrangement with single path Fig igure 3 Arrangement of acoustic paths (US stationary)

2.3 Clamp-On Ultrasonic System The principle of the US Clamp-On system is the same like described in 2.2 Stationary U. An acoustic pulse which is sent upstream travels at a lower absolute speed than an acoustic pulse sent downstream. The average axial velocity of the fluid crossing the path of the pulses is determined by measuring the travel times of the acoustic signal sent in the two directions. Major different to the stationary system is that each path for the clamp-on device travels through the center of the penstock cross section (refer to figure 4). That means the determination of the velocity profile corresponding to the stationary US-device is not possible. For the comparison test it was chosen a one plane arrangement with single path. The choice of the measuring position was limited by accessibility to the penstock. Therefore the measuring section was selected directly after the main inlet valve (MIV) near to the distributor inlet. The conditions for this arrangement were not good because the measuring section was in a conical part of the penstock and the outlet of the measuring sections was only in a distance of app. 1xD to the distributor inlet. Figure 4 Arrangement of acoustic path (US clamp on) 2.4 Needle Opening The flow through the machine can be determined with the needle opening curve as well. The net head and the cross section of the needle opening depend on the needle stroke. The net head results from the determination of the specific hydraulic energy (refer to equation 2 and equation 3) and the needle stroke can be measured directly with any kind of linkage sensor. With the needle stroke the needle cross section can be determined. To achieve an accurate needle opening curve a tested model is beneficial. The results and experience can be adopted to the prototype and the standard flow function can be adjusted. Of course the accuracy is also depending on the deviation between theoretical design of the needle and the manufactured needle at the prototype. That means the more the analogy from design to prototype is fulfilled the merrier is the accuracy of this kind of discharge determination. w = 0,98* 2* g * H equation 6 Standard flow function with loss factor Q = A* w equation 7 Discharge

3 Comparison of discharge values Results of all methods were compared to the results of the thermodynamic efficiency test. Deviations between the different methods and the results of the thermodynamic efficiency test were determined. The results show clearly that the measurement with the clamp on system has significant deviations to the reference measurement. There are several reasons why the deviations are higher than expected compared to the reference. The clamp on system was installed in a slightly conical part of the penstock. This matter did not account for a higher accuracy but does not explain such high deviations. Additionally the system was installed very close to the distributor inlet (because of accessibility to the penstock) were the flow distribution can change keenly when at lower loads not all nozzles are opened. With just one path an adequate determination of the flow velocities over the cross section is not possible especially if there is a highly disturbed flow pattern. With the results achieved from the clamp on system it was not possible to derive a reasonable index test curve because the deviations were not constant and even changed their prefix. Relative deviation of US clamp on to Thermodynamic measurement 6 4 2 Relative deviation [%] 0-2 -4-6 -8-10 -12-14 75,8 75,8 52,2 52,2 61,9 61,9 52,6 52,6 38,4 Needle Opening [%] Figure 5 Relative deviation of US clamp c on to reference measurement

The deviations of the stationary ultrasonic system to the reference measurement are in an acceptable range if you consider that it is a four planes system with single paths arrangement. The deviations of the stationary ultrasonic system are all below 1%. Except of one outlier all deviations have the same prefix and are all in the same magnitude. With values achieved from the stationary ultrasonic device it was possible to reproduce the shape of the efficiency curve according to the results of the reference measurement. For index testing the device deliver acceptable results. Relative deviation of stationary US to Thermodynamic measurement 0,6 0,4 Relative deviation [%] 0,2 0-0,2-0,4-0,6-0,8 75,8 75,8 52,2 52,2 61,9 61,9 52,6 52,6 38,4-1 -1,2 Needle Opening [%] Figure 6 Relative deviation of stationary US to reference measurement The deviations of the needle curve discharge are all below 0.9%. The deviations have all the same prefix and are roughly in the same magnitude. The deviations getting higher to smaller loads of the unit that means in the 2 and 3 nozzle operation of the machine the deviations are higher compared to the reference measurement. With values achieved from the needle curve it was possible to reproduce the shape of the efficiency curve according to the results of the reference measurement. For index testing this method deliver acceptable results. Relative deviation of discharge to Thermodynamic measurement Relative deviation [%] 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0,2 0,1 0 75,8 75,8 52,2 52,2 61,9 61,9 52,6 52,6 38,4 Needle Opening [%] Figure 7 Relative deviation of discharge to reference measurement

4 Summary The results of this comparison show explicit that the choice of the measuring method, the measuring section and the measuring arrangement has to be carefully chosen according the aim of the respective measurement. Furthermore a detailed validation of the test results and the conducted test setup is essential. Especially for the ultrasonic clamp-on discharge measurement special care has to be taken to achieve reasonable results. The general statement that a clamp on device can be easily installed without focus on the right position and setup cannot be confirmed based on the results of this comparison. Contrariwise good measuring conditions are more important to achieve reasonable values. The four plane single path stationary ultrasonic device achieved reasonable results without any correction. This experience confirms that for Index tests ultrasonic devices with a smaller amount of paths can be used properly and without special focus on the borderlines of the measuring setup. For the use at absolute efficiency tests it is strongly recommended to use at least a 4 planes 8 paths system to achieve the necessary accuracy. Otherwise special care has to be taken to measuring set up and the flow distribution (e.g. by CFD). The results of the needle opening curve give quiet good results. Especially if you consider that the effort for this measurement is quiet small. At a Pelton machine just the measurement of the inlet pressure, the electrical power and the needle opening is necessary to achieve an efficiency curve. Even if you don t achieve absolute efficiencies by this method it is a cost effective measurement for Index testing. In this comparison the results agree quiet well to the reference measurement. 5 List of references [1] IEC, Bureau Central de la CEI (1991): International Code for the Field Acceptance Tests to determine the hydraulic performance of hydraulic turbines, storage pumps and pump turbines, Publication 41, third edition, Genève [2] Systec Controls GmbH (2007): Operations and Maintenance Manual of Combined Water loss Detection and Flow Measurement System, Puchheim