NOTICE: This method: The laboratories have to study the instrumental conditions appropriate for their own instrumentation.

Similar documents
Direct Determination of Cadmium and Lead in honey by Electrothermal Atomization Atomic Absorption Spectrometry with Zeeman Effect Correction

Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry

DISCLAIMER: This method:

Title Revision No date DETERMINATION OF HEAVY METALS (ARSENIC, CADMIUM, LEAD AND MERCURY) IN COSMETIC PRODUCTS

Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Cadmium and lead content

DRAFT EAST AFRICAN STANDARD

GB Translated English of Chinese Standard: GB

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction

UNITED NATIONS. ENVIRONMENT PROGRAMME MEDITERRANEAN ACTION PLAN 25 May 2015 Original: English. UNEP(DEPI)/ MED WG.417/Inf.14

Brooklyn College Department of Chemistry

Test Method: CPSC-CH-E

National Research Council Institute for Ecosystem Study Verbania Pallanza - Italy

Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C

Mercury, total-in-sediment, atomic absorption spectrophotometry, nameless, direct

Quality Control Procedures for Graphite Furnace AAS using Avanta Software

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

CHEMISTRY DEPARTMENT

National standard of People s Republic of China

USGS Troy WSC Laboratory Inductively Coupled Plasma- NH4Cl Soil Extracts SOP 425 Jordan Road Rev. No. 2.0 Troy, NY Date: 03/16/2012 Page 1 of 7

Corn Syrup Analysis E-51-1 PHOSPHORUS

Cadmium Reduction Method Method to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters)

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Sodium Chloride - Analytical Standard

A Spectrophotometric Analysis of Calcium in Cereal

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

Sodium Chloride - Analytical Standard

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

[Unless otherwise stated all tolerances are ±5%] SAMPLES

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

DR/4000 PROCEDURE NITRATE. Using Powder Pillows

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

Analysis of domestic sludge using the Agilent 4200 MP-AES

NITROGEN, TOTAL, HR, Test N Tube

DR/4000 PROCEDURE NITRATE. 2. The display will show:

NITROGEN, TOTAL, Test N Tube * Method 10071

The Measurement of Lead in Food Products by Graphite Furnace AA and SpectraAA-40

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

Example method validation and MU approach for Cadmium in seafood test method

Final Report. Characterisation of Sample Report. Job No 2016/11/12-34 AS No. 1234A. Client Example Contact Sample. Signed Date 2017.

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

The analysis of organic acid content of additives, premix, feed, and water.

Cadmium Reduction Method Method 8171 MR (0.1 to 10.0 mg/l NO 3

Cadion Method Method to 0.30 mg/l Cd TNTplus 852

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC)

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

By Donna L. Damrau U.S. GEOLOGICAL SURVEY. Open-File Report Denver, Colorado

Persulfate Digestion Method Method to 150 mg/l N (HR) Test N Tube Vials

Persulfate Digestion Method Method to 25.0 mg/l N (LR) Test N Tube Vials

PRELIMINARY ACTIVITY FOR

Application field / Industry branch:

Laboratory Measurements and Procedures

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

Soil Cation Analysis Using High-Performance Capillary Zone Electrophoresis Last Modified: October 20, 2006

USGS District Laboratory, Troy, NY Dissolved Inorganic Carbon Analysis Standard Operating Procedure

Sulfotepp impurities in Chlorpyrifos EC formulations

PAR Method Method to 2.0 mg/l Pb TNTplus 850

Oxygen Demand, Chemical

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

Tetraphenylborate Method Method to 7.0 mg/l K Powder Pillows

NICKEL-63/59 IN WATER

POLYDEXTROSES. SYNONYMS Modified polydextroses; INS No DEFINITION DESCRIPTION. FUNCTIONAL USES Bulking agent, humectant, stabilizer, thickener

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

ICP-OES Application Note Number 35

CORESTA Recommended Method No. 86

Chromium, Total. Alkaline Hypobromite Oxidation Method 1 Method to 0.70 mg/l Cr (spectrophotometers) 0.01 to 0.60 mg/l Cr (colorimeters)

The Fluorometric Determination of Acetylsalicylic Acid in an Aspirin Tablet

LEAD (Colorimetric) 2. Muffle Furnace: Equipped with pyrometer and capable of operating at controlled temperatures up to 500 C

Technical Procedure for Blood Cannabinoid Liquid-Liquid Extraction (BCLLE) for Analysis by LC-MS/MS

URANIUM IN SOIL. Analytical Procedure (2 GRAM SAMPLE) 1. SCOPE

PAR Method Method to 2.0 mg/l Pb TNTplus 850

For Research Use Only

Annex 2 Formaldehyde

Direct Measurement ISE Method Method to 4.00 mg/l NO 3 N TISAB Solution

Chlorphosphonazo Colorimetric Method Method to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Solution Pillow. Instrument Adapter Sample cell

Chromazurol S Method Method to 0.50 mg/l Al TNTplus 848

ASCORBIC ACID METHOD FOR PHOSPHORUS DETERMINATION

This method describes the identification of the following prohibited colorants in cosmetic products:

METHANOL REFERENCE SPECIFICATIONS

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF

Quality Assurance is what we do to get the right answer for our purpose FITNESS FOR PURPOSE

Aspirin Lab By Maya Parks Partner: Ben Seufert 6/5/15, 6/8/15

FerroZine Method 1 Method to 100 µg/l Fe (10-cm cell) Reagent Solution. Instrument Adapter Sample cell DR 6000 LZV

Sample Preparation LCW 909. Total Kjeldahl Nitrogen, TKN NB: NEW! LCW 909 GB

This protocol is a modified version of the DuBois assay (DuBois et al. 1956) for the quantification of total carbohydrate content of a sample.

Oxygen Demand, Chemical

Nitrogen, ammonia, colorimetry, salicylate-hypochlorite, automated-segmented flow

DR/4000 QUATERNARY AMMONIUM COMPOUNDS PROCEDURE. 2. The display will show: 3. Fill a sample cell (the blank) with 25 ml of deionized water.

Hach Company TNTplus 835/836 Nitrate Method Spectrophotometric Measurement of Nitrate in Water and Wastewater

Determining the Concentration of a Solution: Beer s Law

GAFTI Analytical method for ISO/TS 16179:2012 Detection and Determination of Organotin Compounds in Footwear and Apparel Materials by GC-MS

NATIONAL ASSOCIATION OF TESTING AUTHORITIES (NATA) REQUIREMENTS FOR ACCREDITATION OF ICP-MS TECHNIQUES

Z/zs. tnitiats: wu\ Z-z* I A. sop-c-102. Determination of Chemical Oxygen Demand. Revision 6. Approval: Effective date: 3. Renewat date: 7lt:,:

Analytical Procedures for Monitoring Farmbased Anaerobic Digestion (AD) Systems: PROTOCOL III

Method for Nitrite determination on Low-Range Samples

Transcription:

Determination of Cadmium and Lead in powdered infant formula by Electrothermal Atomization Atomic Absorption Spectrometry with Zeeman Effect Correction NOTICE: This method: - has to be considered only as guideline to help the NRLs to approach the analytical problems of this matrix; - has been developed on the basis of the EU-RL CEFAO experience on GF-AAS technique and it has been applied only on the brand of infant formula used in the 17 th PT; - is not completely validated and the application on different brands and formulations of infant formula is foreseen; - has been developed by EURL CEFAO using the facilities available in its laboratories. The laboratories have to study the instrumental conditions appropriate for their own instrumentation.

CONTENTS 1. SCOPE...3 2. ACRONYMS AND CONVENTIONS...3 3. METHOD DESCRIPTION...3 4. REAGENTS...3 5. SAMPLE TREATMENT- Dry Ashing...4 6. INSTRUMENTAL ANALYSIS...5 7. CALCULATION...8 8. EXPRESSION OF RESULTS...8 Annex 1: Instrumental Settings...9 Page 2 of 10

1. SCOPE The method describes the procedure for the determination of cadmium and lead in powdered infant formula by Z-ETA-AAS, after dry ashing digestion. 2. ACRONYMS AND CONVENTIONS Z-ETA-AAS Electrothermal Atomization Atomic Absorption Spectrometry with Zeeman Effect Correction Sp Suprapure grade Up Ultrapure grade c Concentration expressed in units of milligrams/micrograms per litre RSD r Repeatability relative standard deviation EDL Electrodeless Discharge Lamp THGA Transversely Heated Graphite Atomizer Tubes 3. METHOD DESCRIPTION The determination of Cd and Pb is performed by Z-ETA-AAS after dry ashing sample digestion. Instrumental quantification is based on the matrix matched calibration approach. The sample is digested according to the procedure described at point 5. The calibration curve is prepared as specified in section 6.1.3 for Cd and in section 6.2.3 for Pb, respectively. WARNING: the application of the method includes the use of hazardous materials, operations and equipment. The user is responsible for the appropriate use of safety tools. APPARATUS and EQUIPMENT - Z-ETA-AAS (AAnalyst 800, Perkin Elmer) - Lead: - Tube THGA with end-cap - EDL Lamp - Cadmium: - Tube THGA - EDL Lamp - Analytical balance with 0.1 mg of resolution - Hot plate - Programmable muffle-furnace - Quartz beaker (not less than 50ml) 4. REAGENTS The reagents must have the required adequate purity. Sp or Up grade guarantees that the concentration of the analyte in reagents and water is negligible compared with the level of concentration to be determined. 4.1 HNO 3 Sp, not less than 65% mass fraction, d(hno 3 ) ~1,4 g/ml. 4.1.1 HNO 3 20% v/v. from 4.1 with Up-water. 4.2 Up-water, specific resistance 17 MΩ cm for all samples preparation and dilutions. 4.3 Certified Element Standard Solutions, c = 1000 µg/ml each of Cd and Pb. 4.3.1 Cd 1 mg/l Page 3 of 10

Pipette 0,1 ml of Cd stock solution (4.3) and make up to 100 ml with Up-water in a certified decontaminated volumetric flask 4.3.2 Pb 1 mg/l Pipette 0,1 ml of Pb stock solution (4.3) and make up to 100 ml with Up-water in a certified decontaminated volumetric flask. Prepare these standard solutions in triplicate, transfer to a plastic decontaminated storage bottle (e.g. Kartell), thoroughly mix. 4.4 Ammonium dihydrogen phosphate: NH 4 H 2 PO 4 (99.99 Sp) 4.4.1 Ammonium dihydrogen phosphate (NH 4 H 2 PO 4 ) 100 g/l Example: weigh 10g of NH 4 H 2 PO 4 (4.4) and make up to 100 ml with Up-water in a volumetric flask. 4.5 Magnesium nitrate: Mg(NO 3 ) 2 6H 2 O (99.99 Sp) 4.5.1 Magnesium nitrate (Mg(NO 3 ) 2 ) 6g/l Example: weigh 0.6g of Mg(NO 3 ) 2 (4.5) and make up to 100 ml with Up-water in a volumetric flask. 4.5.2 Magnesium nitrate (Mg(NO 3 ) 2 ) 2g/l Example: weigh 0.2g of Mg(NO 3 ) 2 (4.5) and make up to 100 ml with Up-water in a volumetric flask 4.6 Palladium: Pd (as palladium nitrate (Pd(NO 3 ) 2 )): 10000mg/l in 15% HNO 3 4.7 Triton X-100: TX: reagent for analysis. 4.7.1 Triton X-100 1% (TX1) in water Even if the reagent is liquid, it is easier to prepare the solution by weighting. 5. SAMPLE TREATMENT- Dry Ashing 5.1 Quartz beaker decontamination The use of beakers instead of crucibles is recommended in order to avoid the spattering of the sample. Moreover, to maintain the contamination level under control, it is very important to apply a strict decontamination procedure. Before using the quartz beakers, fill them using HNO 3 20% v/v (4.1.1) and put them on a hot plate at T of about 100 C till evaporation of about 2/3 of the liquid volume, then repeat the procedure two times avoiding the total evaporation of liquid. Rinse the beakers with Up-water (4.2) and let them dry before the use, paying attention to any contamination source. 5.2 Dry Ashing Weigh an amount of about 4g of sample in a quartz beaker and prepare at least one Procedure Blank for each muffle furnace used. Add 2.5 ml of Mg(NO 3 ) 2 g/l (4.5.2) and 5 ml of Up-water (4.2) and dry over a hot plate being careful to properly increase the temperature to avoid the spattering of the sample. After dryness is reached, put the sample in a muffle at an initial T not higher than 200 C; increase the T at a maximum rate of 50 C/h to 400 C. Let the sample stand 12 h. Take the beakers out of the furnace and let them cool; add 2 ml of Up-water (4.2) and 2 ml of HNO 3 Sp (4.1) and put it on the hot plate, take carefully to dryness and repeat the muffle furnace cycle. Repeat the procedure until the ashes are white or slightly coloured. Dissolve the ashing adding 2ml of Up-water (4.2) and 2ml of HNO 3 Sp (4.1) and put it on the hot plate slightly warming till all the ashes are dissolved. Page 4 of 10

Take to a final volume of about 10ml into plastic tubes. Treat the Procedure Blank in the same way of the samples. NOTICE: weigh Falcon tubes before transferring the digested solution and weigh them again after taking to the final volume 6. INSTRUMENTAL ANALYSIS 6.1 Determination of Cadmium 6.1.1 Cd calibration solution: this solution shall be daily prepared 6.1.1.1 c (Cd) = 0,025 µg/l, into a 1ml cuvette for instrumental analysis (example): pipette 1 ml of Up-water (4.2) take off 25µl add 25µl of Cd (5.4.1) mix the solution by pipetting several times a) please note: New tips were used and they were rinsed twice with Up-water, before the use. The micropipette used for mixing shall not be the same used for dilution, nor one used for sample/standard preparation purposes (e.g:. declassified micropipette and used only for mixing). 6.1.2 Matrix modifiers 6.1.2.1 Matrix Modifier Cd: 5g/l NH 4 H 2 PO 4 + 0.3g/l Mg(NO 3 ) 2 + TX 0.1% Example: pipette 2.5ml of NH 4 H 2 PO 4 100 g/l (4.4.1), 2.5 ml of Mg(NO 3 ) 2 6g/l (4.5.1) and 0.5ml TX 1% (4.7.1) in a 50ml volumetric flask. 6.1.3 Calibration Standards In order to save enough solution for analysis, when preparing the calibration curve, it is recommended to mix little aliquots from each of the digested samples (pool of sample). Standards for calibration curve and scheme of preparation: Cd Standard Cd (6.1.1.1) 0.025µg/l (µl) HNO3 20% v/v (4.1.1) (µl) Up-water (4.2) (µl) Blank -- 500 500 -- Base -- 250 500 250 Std 1 (0.25 µg/l) 20 500 980 500 Std 2 (0.5 µg/l) 20 250 480 250 Std 3 (0.75 µg/l) 60 500 940 500 Std 4 (1.0 µg/l) 40 250 460 250 Std 5 (1.5 µg/l) 60 250 440 250 Page 5 of 10 Pool of sample (µl) 6.1.4 Preparation of calibration standards: 6.1.4.1 Blank: a cuvette for instrumental analysis (example): example: pipette 500 µl Up-water (4.2) + 500 µl of HNO 3 20% v/v (4.1.1) (µl) mix thoroughly with a dedicated micropipette (see 6.1.1.1 a) 6.1.4.2 Base: in a cuvette for instrumental analysis (example): pipette 500 µl Up-water (4.2) + 250 µl of HNO 3 20% v/v (4.1.1) (µl) +250 µl of Pool of sample mix thoroughly by pipetting (see 6.1.1.1 a)

6.1.4.3 Standards 1, 3: in a 5ml falcon tube (example): pipette 1000 µl of Up-water (4.2) take off the amount of standard to be added (e.g. for standard 1, take off 20µl) add 500 µl of HNO 3 20% v/v (4.1.1) + 500 µl of Pool of sample add the calibration solution and mix thoroughly pipette 1ml of the obtained solution in a cuvette for instrumental analysis. 6.1.4.4 Standards 2, 4, 5: in a cuvette for instrumental analysis (example): pipette 500 µl of Up-water (4.2) take off the amount of standard to be added (e.g. for standard 2, take off 20µl) add 250 µl of HNO 3 20% v/v (4.1.1) +250 µl of Pool of sample add the calibration solution and mix thoroughly by pipetting (see 6.1.1.1 a). 6.1.5 Sample Dilution 6.1.5.1 Minimum dilution 1:4: into a 1 ml cuvette for instrumental analysis (example): pipette 500µl of Up-water (4.2) add 250µl of HNO 3 20% (4.1.1) + 250µl of sample and mix thoroughly by pipetting (see 6.1.1.1 a). 6.1.5.2 Further dilutions, e.g. 1:10: into a 1 ml cuvette for instrumental analysis (example): pipette 500 µl of Up-water (4.2) add 400 µl of HNO 3 20% v/v (4.1.1) add 100 µl of sample and mix thoroughly by pipetting (see 6.1.1.1 a). 6.1.6 Drift Check Drift is checked by analyzing blank and first standard: at the end of an analysis, if the number of samples analyzed is less than 8; after each series of 8 samples; at the end of an analysis, if more than 3 samples have been run after the last check. If the instrumental drift is higher than 7%, repeat the calibration curve and read the previous samples up to the last acceptable check. 6.1.7 Spectrometer Settings Optimize the instrument in accordance with the recommendation described in the internal procedures. Set ashing and atomization temperature taking into account the instrument used and the ageing of the spare parts (tubes, contacts, furnace). Ashing and atomization temperature shall anyway fall in the following ranges: Ashing temperature: 400-600 C. Atomization temperature: 1600-1800 C. 6.2 Determination of Lead 6.2.1 Pb calibration solutions: this solution shall be daily prepared (example): 6.2.1.1 c(pb) = 250 µg/l, into a 1 ml cuvette for instrumental analysis pipette 750 µl of Up-water (5.3) add 250 µl of Pb (5.4.2) and thoroughly mix by pipetting (see 6.1.1.1 a) Page 6 of 10

6.2.2 Matrix modifiers 6.5.2.1: 0.25g/l Pd + 0.2g/l Mg(NO 3 ) 2 Example: pipette 1.25ml of Pd (4.6), 1.7 ml of Mg(NO 3 ) 2 6g/l (4.5.1) in a 50ml volumetric flask. 6.2.3 Calibration standards In order to save enough solution for analysis, when preparing the calibration curve, it is recommended to mix little aliquots from each of the digested samples (pool of sample). Standards for calibration curve and scheme of preparation: Pb Standard Pb 250 µg/l (6.2.1.1) (µl) HNO3 20% v/v (4.1.1) (µl) Up water (4.2) (µl) Pool of sample (µl) Blank -- 500 500 -- Base -- 250 500 250 Std 1 (2.5 µg/l) 20 500 980 500 Std 2 (5 µg/l) 20 250 480 250 Std 3 (10 µg/l) 40 250 460 250 Std 4 (15 µg/l) 60 250 440 250 Std 5 (20 µg/l) 80 250 420 250 6.2.4 Preparation of calibration standard 6.2.4.1 Blank: in a cuvette for instrumental analysis (example): pipette 500 µl Up-water (4.2) + 500 µl of HNO 3 20% v/v (4.1.1) and thoroughly mix by pipetting (see 6.1.1.1 a) 6.2.4.2 Base: in a cuvette for instrumental analysis (example): pipette 500 µl Up-water (4.2) + 250 µl of HNO 3 20% v/v (4.1.1) + 250 µl of Pool of sample and thoroughly mix by pipetting (see 6.1.1.1 a). 6.2.4.3 Standards 1: in a 5ml falcon tube (example): pipette 1000 µl Up water (4.2) take off the amount of standard to be added (20µl) add 500 µl of Up-water (4.2) + 500 µl of Pool of sample add the calibration solution and mix thoroughly pipette 1ml of the obtained solution in a cuvette for instrumental analysis. 6.2.4.4 Standards (2, 3, 4, 5) in a cuvette for instrumental analysis (example) pipette 500 µl of Up-water (4.2) take off the amount of standard to be added (e.g. for standard 3, take off 40µl) add 250 µl of HNO 3 20% v/v (4.1.1) + 250 µl of Pool of sample add the calibration solution and thoroughly mix by pipetting (see 6.1.1.1 a) 6.2.5 Sample Dilution 6.2.5.1 Minimum dilution 1:4: into a 1 ml cuvette for instrumental analysis (example): pipette 500 µl of Up-water (4.2) add 250 µl of HNO 3 20% v/v (4.1.1) add 250 µl of sample and thoroughly mix by pipetting (see 6.1.1.1 a) 6.2.5.2 Further dilutions, e.g. 1:10: into a 1 ml cuvette for instrumental analysis (example) : pipette 500 µl of Up-water (4.2) Page 7 of 10

add 400 µl of HNO 3 20% v/v (4.1.1) add 100 µl of sample and thoroughly mix by pipetting (see 6.1.1.1 a). 6.2.6 Drift Check Drift is checked by analyzing blank and the first standard: at the end of an analysis, if the number of samples analyzed is less than 8; after each series of 8 samples; at the end of an analysis, if more than 3 samples have been run after the last check. If the instrumental drift is higher than 10%, repeat the calibration curve and read the previous samples up to the last acceptable check. 6.2.7 Spectrometer Settings Optimize the instrument in accordance with the recommendation described in internal procedures. Set ashing and atomization temperature taking into account the instrument used and the ageing of the spare parts (tubes, contacts, furnace). Ashing and atomization temperature shall anyway fall in the following ranges: Ashing temperature: 800-1000 C. Atomization temperature: 1600-1800 C. 7. CALCULATION Calculate the content, w, of the chemical element as mass fraction mg/kg as follows: w = D a V m 1000 where: a = is the concentration of the element in the test solution in μg/l V = final volume of the solution in ml m = weight of the sample in g Please note: the concentration of procedure blank is not considered in the final calculation. Its value in the procedural digested blank was for Cd <0.1 µg/l and for Pb <1 µg/l. Calculate V as follows: V= (Pf-Pi)/d where: Pi = weight of the empty falcon tubes Pf = weight of the falcon tubes containing the digested solution d = weight of 1 ml of digested solution (please note, if you perform this procedure after digestion, allow samples to reach room temperature) 8. EXPRESSION OF RESULTS Express the final result, always considering the average of three independent sample preparations. Page 8 of 10

PARAMETERS OF THE EURL CEFAO METHOD LoD and LoQ were determined using 21 aliquots of a sample of commercial infant formula. Repeatability was evaluated using a powdered infant formula spiked with Cd and Pb and then freeze-dried: 12 aliquots were used. The recovery was performed on milk sample of the 14th PT 2nd Round, quantified using the calibration curve prepared in the pool of samples of the infant formula. The parameters obtained during the method development are summarized as follows: Parameter Cd Pb LoD (=3*SD) µg/kg 0.6 3.6 LoQ (=10*SD) µg/kg 2 12 RSDr % 2.3 6.6 Recovery % on 14 th PT, 2 nd round 98 107 FINAL CONSIDERATIONS This method has been developed on the basis of the EU-RL CEFAO experience on GF-AAS technique. As for Pb, the use of the Tube THGA with end-caps allows the achievement of a suitable sensitivity. The external calibration approach is possible for Cd, but it is necessary to investigate the effect of acidity/matrix. Page 9 of 10

Annex 1: Instrumental Settings The annexes are the instrumental report in paper form Annex 1a: Cd (4 pages) Annex 1b: Pb (4 pages) Page 10 of 10

Method Name: Cd_inf_form_add Define Element Method Description : Milk dry ashing + infant formula Spectrometer Element : Cd Wavelength (nm) : 228.8 Slit Width (nm) : 0.7L Signal Type : AA - BG Measurement : Peak Area Settings Read Parameters Time (sec) : 3.0 Delay Time (sec) : 0.0 BOC Time (sec) : 2 Replicates... Same for All Samples : 3 Lamp Current Use value entered in Lamp Setup window Furnace Program Step Temp( C) Ramp Time Hold Time Internal Flow Gas Type 1 110 1 30 250 Normal 2 130 15 30 250 Normal 3 500 10 20 250 Normal 4 1700 0 3 0 Normal 5 2450 1 3 250 Normal Read Step : 4 Injection Temperature( C) : 20 No extra furnace cleanout. Furnace Autosampler Sample Volume : 20 ul Diluent Volume : 0 ul Diluent Location : 1 Matrix Modifiers #1 Volume : 5 ul Location : 40 Add to calibration blank and standards. Add to reagent blank and samples. #2 Volume : 0 ul Location : 1 Add to calibration blank and standards. Add to reagent blank and samples. Autosampler and Furnace Sequence Step Actions and Parameters A Pipet diluent + modifier1 + spike + sample/std B Run furnace steps 1 to end Pipet Speed... Take up : 100% Dispensing : 100% Page 1 12/06/2012 08:56:20

Method Name: Cd_inf_form_add Calibration Equation and Units Equation : Method of Additions Calibrate Maximum Decimal Places : 3 Maximum Significant Figures : 4 Analyst-prepared additions. Calibration Units : ug/l Sample Units : ug/l Calibration Standard Concentrations ID Concentration A/S Loc Stock(uL) Diluent(uL) Calib Blank Bianco 1 20 Addition 1 st 0.25 ppb 0.25 2 20 Addition 2 st 0.5 ppb 0.50 3 20 Addition 3 st 0.75 ppb 0.75 4 20 Addition 4 st 1.00 ppb 1.00 5 20 Addition 5 st 1.50 ppb 1.50 6 20 Initial Calibration Options When opening this method manually: Clear calibration curve(s) and construct a new calib curve. When using this method in a multimethod sequence: Start by constructing new calibration curves. Calibration Check Correlation coefficient checking is not enabled in this method. Recalibration Periodic recalibration is not enabled in this method. Analyze standards at end of analysis is not enabled in this method. Precision Checks Precision checking is not enabled in this method. Beyond Calibration Range Beyond calibration range checking is not enabled in this method. Matrix Recovery Matrix recovery checking is not enabled in this method. Automatic Recovery Page 2 12/06/2012 08:56:20

Method Name: Cd_inf_form_add Automatic recovery checking is not enabled in this method. QC Sample Definition A/S Count as Subtract QC Sample ID Loc Sample Reagent Blank QC Sample Concentrations and Limits Schedule for QC Analyses After After QC Sample ID Init Cal Recal Periodic Freq At End Periodic Timing of Analyses Frequency... Same for all QC's : 1 Count : Samples Failure Actions for After-Calibration QC's Times to When All Additional QC Sample ID Retry QC Tries Fail Message Failure Actions for Periodic QC's Times to When All Additional QC Sample ID Retry QC Tries Fail Message Failure Actions for At-End QC's Times to When All Additional QC Sample ID Retry QC Tries Fail Message Maximum Retries After QC Failure After a group of standards or unknowns has been reanalyzed 1 times, then Continue Options Include in Results Display and Printed Log: Headers: * Analytical Header * Method Header (Short) * Sample Header (Short) Start each sample on a new page Sample Data Items: Summary Items: * Replicate Data Analysis List * Means and Statistics * Matrix Test Reports Transient Peak Plots (First) * Calibration Summary * Calibration Curves Save with Results: * Transient Peak Profiles Page 3 12/06/2012 08:56:20

Method Name: Cd_inf_form_add Remarks: Mod: NH4H3PO4 5g/l + Mg(NO3)2 0.3 g/l + Triton X 0.1% Standards prepared in HNO3 20% diluted 1:2 with up water. Samples diluted at least 1:4 (500 ul H2O + 250 ul HNO3 20% + 250 ul sample) Page 4 12/06/2012 08:56:20

Method Name: Pb_milk_infant_form Define Element Method Description : Milk dry ashing Spectrometer Element : Pb Wavelength (nm) : 283.3 Slit Width (nm) : 0.7L Signal Type : AA - BG Measurement : Peak Area Settings Read Parameters Time (sec) : 3.0 Delay Time (sec) : 0.0 BOC Time (sec) : 2 Replicates... Same for All Samples : 3 Lamp Current Use value entered in Lamp Setup window Furnace Program Step Temp( C) Ramp Time Hold Time Internal Flow Gas Type 1 110 1 30 250 Normal 2 130 15 30 250 Normal 3 450 15 20 250 Normal 4 900 15 25 250 Normal 5 1700 0 3 0 Normal 6 2450 1 5 250 Normal Read Step : 5 Injection Temperature( C) : 20 No extra furnace cleanout. Furnace Autosampler Sample Volume : 20 ul Diluent Volume : 0 ul Diluent Location : 1 Matrix Modifiers #1 Volume : 5 ul Location : 40 Add to calibration blank and standards. Add to reagent blank and samples. #2 Volume : 0 ul Location : 1 Add to calibration blank and standards. Add to reagent blank and samples. Autosampler and Furnace Sequence Step Actions and Parameters A Pipet diluent + modifier1 + spike + sample/std B Run furnace steps 1 to end Pipet Speed... Take up : 100% Dispensing : 100% Page 1 12/06/2012 08:57:41

Method Name: Pb_milk_infant_form Calibration Equation and Units Equation : Method of Additions Calibrate Maximum Decimal Places : 3 Maximum Significant Figures : 4 Analyst-prepared additions. Calibration Units : ug/l Sample Units : ug/l Calibration Standard Concentrations ID Concentration A/S Loc Stock(uL) Diluent(uL) Calib Blank Bianco 1 20 Addition 1 st 2.5 ppb 2.5 3 20 Addition 2 st 5 ppb 5.0 4 20 Addition 3 st 10 ppb 10.0 5 20 Addition 4 st 15 ppb 15.0 6 20 Addition 5 st 20 ppb 20.0 7 20 Initial Calibration Options When opening this method manually: Clear calibration curve(s) and construct a new calib curve. When using this method in a multimethod sequence: Start by constructing new calibration curves. Calibration Check Correlation coefficient checking is not enabled in this method. Recalibration Periodic recalibration is not enabled in this method. Analyze standards at end of analysis is not enabled in this method. Precision Checks Precision checking is not enabled in this method. Beyond Calibration Range Beyond calibration range checking is not enabled in this method. Matrix Recovery Matrix recovery checking is not enabled in this method. Automatic Recovery Page 2 12/06/2012 08:57:41

Method Name: Pb_milk_infant_form Automatic recovery checking is not enabled in this method. QC Sample Definition A/S Count as Subtract QC Sample ID Loc Sample Reagent Blank QC Sample Concentrations and Limits Schedule for QC Analyses After After QC Sample ID Init Cal Recal Periodic Freq At End Periodic Timing of Analyses Frequency... Same for all QC's : 1 Count : Samples Failure Actions for After-Calibration QC's Times to When All Additional QC Sample ID Retry QC Tries Fail Message Failure Actions for Periodic QC's Times to When All Additional QC Sample ID Retry QC Tries Fail Message Failure Actions for At-End QC's Times to When All Additional QC Sample ID Retry QC Tries Fail Message Maximum Retries After QC Failure After a group of standards or unknowns has been reanalyzed 1 times, then Continue Options Include in Results Display and Printed Log: Headers: * Analytical Header * Method Header (Short) * Sample Header (Short) Start each sample on a new page Sample Data Items: Summary Items: * Replicate Data Analysis List * Means and Statistics * Matrix Test Reports Transient Peak Plots (Last) * Calibration Summary Calibration Curves Save with Results: Page 3 12/06/2012 08:57:41

Method Name: Pb_milk_infant_form * Transient Peak Profiles Remarks: Mod.: Pd(NO3)2 0.25 g/l + Mg(NO3)2 0.2 g/l THGA Tube with end caps. Standard prepared in HNO3 20% diluted 1:2 with up water. Samples diluted at least 1:4 (500 ul H2O + 250 ul HNO3 20% + 250ul sample). Page 4 12/06/2012 08:57:41