Direct Determination of Cadmium and Lead in honey by Electrothermal Atomization Atomic Absorption Spectrometry with Zeeman Effect Correction

Similar documents
Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry

NOTICE: This method: The laboratories have to study the instrumental conditions appropriate for their own instrumentation.

DISCLAIMER: This method:

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS

Title Revision No date DETERMINATION OF HEAVY METALS (ARSENIC, CADMIUM, LEAD AND MERCURY) IN COSMETIC PRODUCTS

Cadmium and lead content

Brooklyn College Department of Chemistry

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction

DRAFT EAST AFRICAN STANDARD

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

USGS Troy WSC Laboratory Inductively Coupled Plasma- NH4Cl Soil Extracts SOP 425 Jordan Road Rev. No. 2.0 Troy, NY Date: 03/16/2012 Page 1 of 7

Quality Control Procedures for Graphite Furnace AAS using Avanta Software

Analysis of domestic sludge using the Agilent 4200 MP-AES

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Cadmium Reduction Method Method to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters)

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

National Research Council Institute for Ecosystem Study Verbania Pallanza - Italy

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

Example method validation and MU approach for Cadmium in seafood test method

CHEMISTRY DEPARTMENT

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

Cadion Method Method to 0.30 mg/l Cd TNTplus 852

UNITED NATIONS. ENVIRONMENT PROGRAMME MEDITERRANEAN ACTION PLAN 25 May 2015 Original: English. UNEP(DEPI)/ MED WG.417/Inf.14

POLYDEXTROSES. SYNONYMS Modified polydextroses; INS No DEFINITION DESCRIPTION. FUNCTIONAL USES Bulking agent, humectant, stabilizer, thickener

GB Translated English of Chinese Standard: GB

Sodium Chloride - Analytical Standard

DR/4000 PROCEDURE NITRATE. 2. The display will show:

PAR Method Method to 2.0 mg/l Pb TNTplus 850

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

Mercury, total-in-sediment, atomic absorption spectrophotometry, nameless, direct

Test Method: CPSC-CH-E

Chromazurol S Method Method to 0.50 mg/l Al TNTplus 848

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

Sulfotepp impurities in Chlorpyrifos EC formulations

Sodium Chloride - Analytical Standard

By Donna L. Damrau U.S. GEOLOGICAL SURVEY. Open-File Report Denver, Colorado

LEAD (Colorimetric) 2. Muffle Furnace: Equipped with pyrometer and capable of operating at controlled temperatures up to 500 C

NATIONAL ASSOCIATION OF TESTING AUTHORITIES (NATA) REQUIREMENTS FOR ACCREDITATION OF ICP-MS TECHNIQUES

A Spectrophotometric Analysis of Calcium in Cereal

PAR Method Method to 2.0 mg/l Pb TNTplus 850

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

The analysis of organic acid content of additives, premix, feed, and water.

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

DR/4000 PROCEDURE NITRATE. Using Powder Pillows

Cadmium Reduction Method Method 8171 MR (0.1 to 10.0 mg/l NO 3

Impact factor: 3.958/ICV: 4.10 ISSN:

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

Product Safety Reference Manual. Book 5 - Laboratory Policies and Procedures C

Method for Nitrite determination on Low-Range Samples

Tetraphenylborate Method Method to 7.0 mg/l K Powder Pillows

Determination of urea in ultrapure water by IC-MS/MS

Quality Assurance is what we do to get the right answer for our purpose FITNESS FOR PURPOSE

Chlorphosphonazo Colorimetric Method Method to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Solution Pillow. Instrument Adapter Sample cell

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

NITROGEN, TOTAL, HR, Test N Tube

DR/4000 QUATERNARY AMMONIUM COMPOUNDS PROCEDURE. 2. The display will show: 3. Fill a sample cell (the blank) with 25 ml of deionized water.

Technology that counts

NITROGEN, TOTAL, Test N Tube * Method 10071

Mercury Determination in Lichen, BCR-482, Using the QuickTrace M-7600 CVAAS Mercury Analyzer

Nitrogen, Total Inorganic

GAFTI Analytical method for ISO/TS 16179:2012 Detection and Determination of Organotin Compounds in Footwear and Apparel Materials by GC-MS

Standard Operating Procedures. Determination of Anions and/or Cations Extracted from Nylon Filters by Ion Chromatography (IC)

Laboratory Measurements and Procedures

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

[Unless otherwise stated all tolerances are ±5%] SAMPLES

PRELIMINARY ACTIVITY FOR

METHOD 9252A CHLORIDE (TITRIMETRIC, MERCURIC NITRATE)

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

USGS District Laboratory, Troy, NY Dissolved Inorganic Carbon Analysis Standard Operating Procedure

Hach Company TNTplus 835/836 Nitrate Method Spectrophotometric Measurement of Nitrate in Water and Wastewater

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

SOUTH AFRICAN NATIONAL STANDARD. Standard test methods for lead in water

Nitrogen, Ammonia. Test Preparation. Powder Pillows Method Method 8155 Salicylate Method 1 Powder Pillows

Persulfate Digestion Method Method to 150 mg/l N (HR) Test N Tube Vials

Persulfate Digestion Method Method to 25.0 mg/l N (LR) Test N Tube Vials

Salicylate Method Method HR (2 to 47 mg/l NH 3 N) TNTplus 832

Soil Cation Analysis Using High-Performance Capillary Zone Electrophoresis Last Modified: October 20, 2006

Annex 2 Formaldehyde

Elemental analysis of river sediment using the Agilent 4200 MP-AES

USGS Troy WSC Laboratory Ion Chromatography SOP EPA 300.0, Rev Jordan Road SOP. No. 1 Rev. No. 1.7 Troy, NY Date 01/25/18 Page 1 of 7

Z/zs. tnitiats: wu\ Z-z* I A. sop-c-102. Determination of Chemical Oxygen Demand. Revision 6. Approval: Effective date: 3. Renewat date: 7lt:,:

Chloramine (Mono) and Nitrogen, Free Ammonia

METHOD 7B - DETERMINATION OF NITROGEN OXIDE EMISSIONS FROM STATIONARY SOURCES (ULTRAVIOLET SPECTROPHOTOMETRIC METHOD)

METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC)

DETERMINATION OF NITRATE IN 2M KCl SOIL EXTRACTS BY FLOW INJECTION ANALYSIS NITRATE REDUCTASE

DETERMINATION OF NITRATE IN BRACKISH WATERS BY FLOW INJECTION ANALYSIS NITRATE REDUCTASE

Corn Syrup Analysis E-51-1 PHOSPHORUS

METHANOL REFERENCE SPECIFICATIONS

Nitrogen, ammonia, colorimetry, salicylate-hypochlorite, automated-segmented flow

DR/4000 PROCEDURE. HARDNESS, Total

PA-DEP 3686, Rev. 1. Light Hydrocarbons in Aqueous Samples via Headspace and Gas Chromatography with Flame Ionization Detection (GC/FID)

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

Introduction to Spectroscopy: Analysis of Copper Ore

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

Spectrophotometric Determination of Ferrocyanide in Effluents

On the use of Deming and quadratic calibrations in analytical chemistry

Transcription:

NOTICE: This method: Direct Determination of Cadmium and Lead in honey by Electrothermal Atomization Atomic Absorption Spectrometry with Zeeman Effect Correction - has to be considered only as guideline to help the NRLs to approach the analytical problems of this matrix. - is developed according to the internal procedure PGVM2.00-11 Validation of Method ; - has been developed by EURL-CEFAO using the facilities available in its laboratories. - the quantification is based on the matrix-matched calibration approach (see 6.1.3 and 6.2.3). The blank sample sent together with the PT items can be used for the construction of the calibration curve.

CONTENTS 1. SCOPE... 3 2. ACRONYMS AND CONVENTIONS... 3 3. METHOD DESCRIPTION... 3 3.1 Apparatus and Equipment... 3 4. REAGENTS... 3 5. SAMPLE TREATMENT... 4 6. INSTRUMENTAL ANALYSIS... 4 6.1 Determination of Cd... 4 6.1.1 Working standard solutions... 4 6.1.2 Matrix modifier Cd: 3g/l NH 4 H 2 PO 4 in 0.05% TX... 5 6.1.3 Calibration Standards... 5 6.1.3.1 Preparation of calibration standards... 5 6.1.4 Sample Dilution... 5 6.1.5 Drift Check... 6 6.1.6 Spectrometer Settings... 6 6.2 Determination of Pb... 6 6.2.1 Working standard solutions... 6 6.2.2 Matrix Modifier Pb: 3g/l NH 4 H 2 PO 4 + 0.25g/l Mg(NO 3 ) 2 + 0.05% TX.... 6 6.2.3 Calibration Standards... 6 6.2.3.1 Preparation of calibration standards... 6 6.2.4 Sample Dilution... 7 6.2.5 Drift Check... 7 6.2.6 Spectrometer Settings... 7 7. CALCULATION... 7 8. EXPRESSION OF RESULTS... 8 9. PARAMETERS OF THE EURL-CEFAO METHOD... 8 Annex 1: Instrumental Settings for Cd... 9 Annex 2: Instrumental Settings for Pb... 10 Page 2 of 10

1. SCOPE The method describes the procedure for the determination of cadmium and lead in diluted honey by Z-ETA-AAS. 2. ACRONYMS AND CONVENTIONS Z-ETA-AAS Electrothermal Atomization Atomic Absorption Spectrometry with Zeeman Effect Correction sp Suprapure grade up Ultrapure grade d density c Concentration expressed in units of milligrams/micrograms per litre RSD r Relative Standard Deviation under repeatability conditions EDL Electrodeless Discharge Lamp THGA Transversely Heated Graphite Atomizer Tubes Pool of Sample Blanks PSBs 3. METHOD DESCRIPTION The determination of Cd and Pb are performed by Z-ETA-AAS on diluted honey; the procedure is described at point 5. Instrumental quantification is based on the calibration addition approach. If a blank matrix is available, it should be used to prepare the matrix-matched standards for calibration; different preparations can be pooled (Pool of Sample Blanks-PSBs). If a blank matrix is unavailable, it is also possible to prepare the matrix matched standards in a pool of the samples to be analysed. The calibration curve is prepared as specified in section 6.1.3 for Cd and 6.2.3 for Pb. WARNING: the application of the method includes the use of hazardous materials, operations and equipment. The user is responsible for the appropriate use of safety tools. 3.1 Apparatus and Equipment - Z-ETA-AAS (AAnalyst 800, Perkin Elmer) - Graphite Tubes THGA - EDL Lamps for Cd and Pb - Ultrasonic Bath (Bandelin Sonorex Super RK 514 H) - Analytical scale (0.1 mg resolution) 4. REAGENTS The reagents must have the required adequate purity. Sp or up grade guarantees that the concentration of the analyte in reagents and water is negligible compared with the level of concentration to be determined. 4.1 HNO 3 sp, not less than 65% mass fraction, d(hno 3 ) ~1,4 g/ml 4.1.1 HNO 3 2.5% v/v. from HNO 3 (4.1) with Up-water. 4.2 Hydrogen peroxide sp, w(h 2 O 2 ) =30% 4.3 Up-water, specific resistance 17 MΩ cm for all samples preparation and dilutions 4.4 Certified Element Standard Solutions Cd, c = 1000 µg/ml 4.4.1 Cd 1mg/l Pipette 0,1 ml of Cd stock solution (4.4) and make up to 100 ml with up-water (4.3) in a certified decontaminated volumetric flask. Page 3 of 10

Prepare these standard solutions in triplicate, transfer to a plastic decontaminated storage bottle (e.g. Kartell), thoroughly mix. 4.5 Certified Element Standard Solutions Pb, c = 1000 µg/ml 4.5.1 Pb 1mg/l Pipette 0,1 ml of Pb stock solution (4.5) and make up to 100 ml with up-water (4.3) in a certified decontaminated volumetric flask. Prepare these standard solutions in triplicate, transfer to a plastic decontaminated storage bottle (e.g. Kartell), thoroughly mix. 4.6 Ammonium dihydrogen phosphate: NH 4 H 2 PO 4 (99.99 sp) 4.6.1 Ammonium dihydrogen phosphate (NH 4 H 2 PO 4 ) 100 g/l Example: weigh 10g of NH 4 H 2 PO 4 (4.6) and make up to 100 ml with water in a volumetric flask. 4.7 Magnesium nitrate: Mg(NO 3 ) 2 6H 2 O (99.99 sp) 4.7.1 Magnesium nitrate (Mg(NO 3 ) 2 ) 5g/l Example: weigh 0.5g of Mg(NO 3 ) 2 (4.7) and make up to 100 ml with water in a volumetric flask 4.8 Triton X-100: TX: reagent for analysis. 4.8.1 Triton X-100 1% (TX1) Example: weigh 1g of TX (4.8) and make up to 100 ml with water in a volumetric flask. 5. SAMPLE TREATMENT Weigh about 1.3g of sample into a 50ml Falcon tube. Afterwards, add 0.5 ml HNO3 and 2.5 ml H2O2 and dilute the solution to about 20ml with upwater and shake thoroughly. Put the tubes in an ultrasonic bath for at least 15. NOTICE: weigh Falcon tubes before weighing honey (Pi) and weigh them again after taking to the final volume (Pf). 6. INSTRUMENTAL ANALYSIS a) please note: New tips and cuvettes were used and they were rinsed at least once with up-water, before their use. Cuvettes are also decontaminated before their use by letting them stand overnight filled with a 10% HNO 3 aqueous solution The micropipette used for mixing shall not be the same used for dilution, nor one used for sample/standard preparation purposes (e.g:. declassified micropipette and used only for mixing). 6.1 Determination of Cd 6.1.1 Working standard solutions These solutions shall be daily prepared 6.1.1.1 c (Cd) = 0,025 mg/l, into a 1ml cuvette for instrumental analysis (example): pipette 1.0 ml of up water (4.3) take off 25µl add 25µl of Cu 1mg/l (4.4.1) mix the solution by pipetting several times (see 6 a) 6.1.1.2 c (Cd) = 0,050 mg/l, into a 1ml cuvette for instrumental analysis (example): pipette 1.0 ml of up water (4.3) take off 50µl add 25µl of Cu 1mg/l (4.4.1) mix the solution by pipetting several times (see 6 a) Page 4 of 10

6.1.2 Matrix modifier Cd: 3g/l NH 4 H 2 PO 4 in 0.05% TX Example: pipette 1.5ml of NH 4 H 2 PO 4 100 g/l (4.6.1) and 0.5 ml of TX1 1% (4.8.1) and make up with up-water in a 50ml volumetric flask. 6.1.3 Calibration Standards Table 2. Scheme of preparation calibration curve for Cd in honey: Standard HNO 3 2.5% (4.4.1) (µl) PSBs (µl) Cd (6.1.1.1) (µl) Cd (6.1.1.2) (µl) Blank 1000 -- -- -- Base 500 500 Std 1 (0.25 µg/l) 980 1000 20 -- Std 2 (0.5 µg/l) 480 500 20 -- Std 3 (1.0 µg/l) 480 500 -- 20 Std 4 (1.5 µg/l) 460 500 20 20 Std 5 (2.0 µg/l) 460 500 -- 40 6.1.3.1 Preparation of calibration standards 6.1.3.1.1 Blank: in a cuvette for instrumental analysis (example): pipette 1.0 ml of HNO 3 2.5%(4.1.1) 6.1.3.1.2 Base: in a cuvette for instrumental analysis (example): pipette 0.50 ml of HNO 3 2.5% (4.1.1) pipette 0.50 ml of PSBs mix the solution by pipetting several times (see 6 a). 6.1.3.1.3 Standard 1 : in a 5ml falcon tube (example): pipette 1.0 ml of HNO 3 2.5% (4.1.1) take off 20µl add 20µl of Cd (6.1.1.1) and 1000 µl of Pool of Sample Blanks (PBSs) mix thoroughly pipette 1ml of the obtained solution in a cuvette for instrumental analysis. 6.1.3.1.4 Standards 2, 3, 4, 5: in a cuvette for instrumental analysis (example): pipette 500 µl of HNO3 2.5% (4.1.1) take off the amount of standard to be added (e.g. for standard 2, take off 20µl) add the calibration solution (e.g. for standard 2, add 20µl f Cd 0.025mg/l (6.1.1.1)) add 500µl of Pool of Sample Blanks (PSBs) mix thoroughly by pipetting (see 6 a). 6.1.4 Sample Dilution 6.1.4.1 Minimum dilution 1:2; into a 1 ml cuvette for instrumental analysis (example): pipette 500µl of HNO3 2.5% (4.1.1) add 500µl of sample and mix thoroughly by pipetting (see 6 a). 6.1.4.2 Further dilution e.g. 1:10: into a 1 ml cuvette for instrumental analysis (example): pipette 400µl Pool of Sample Blanks (PSBs) add 100µl of sample pipette 500µl of HNO3 2.5% (4.1.1) and mix thoroughly by pipetting (see 6 a). Page 5 of 10

6.1.5 Drift Check Drift is checked by analyzing the second and the fourth standard: at the end of an analysis, if the number of samples analyzed is less than 8; after each series of 8 samples; at the end of an analysis, if more than 3 samples have been run after the last check. If the instrumental drift is higher than the maximum value set in the method, repeat the calibration curve and read the previous samples up to the last acceptable check. 6.1.6 Spectrometer Settings Optimize the instrument in accordance with the recommendation described in the internal procedures. The thermic program is reported in Annex 1. 6.2 Determination of Pb 6.2.1 Working standard solutions These solutions shall be daily prepared 6.2.1.1 c (Pb) = 0,25 mg/l, into a 1ml cuvette for instrumental analysis (example): pipette 750 ml of up water (4.3) add 250ml of Pb 1 mg/l (4.5.1) mix the solution by pipetting several times (see 6 a). 6.2.1.2 c (Pb) = 0,50 mg/l, into a 1ml cuvette for instrumental analysis (example): pipette 0.50 ml of up water (4.3) add 0.50ml of Pb 1 mg/l (4.5.1) mix the solution by pipetting several times (see 6 a). 6.2.2 Matrix Modifier Pb: 3g/l NH 4 H 2 PO 4 + 0.25g/l Mg(NO 3 ) 2 in 0.05% TX. Example: pipette 1.5ml of NH 4 H 2 PO 4 100 g/l (4.6.1), 2.5 ml of Mg(NO 3 ) 2 5g/l (4.7.1) and 0.5 ml of TX1 1% (4.8.1) and make up with up-water in a 50ml volumetric flask. 6.2.3 Calibration Standards Table 3. Scheme of preparation calibration curve for Pb in honey: Standard HNO 3 2.5% (4.4.1) (µl) PSBs (µl) Pb (6.2.1.1) (µl) Pb (6.2.1.2) (µl) Blank 1000 -- -- -- Base 500 500 -- Std 1 (0.25 µg/l) 980 1000 20 -- Std 2 (0.5 µg/l) 480 500 20 -- Std 3 (1.0 µg/l) 480 500 -- 20 Std 4 (1.5 µg/l) 460 500 20 20 Std 5 (2.0 µg/l) 460 500 -- 40 6.2.3.1 Preparation of calibration standards 6.2.3.1.1 Blank: in a cuvette for instrumental analysis (example): pipette 1.0 ml of HNO 3 2.5% (4.1.1) 6.2.3.1.2 Base: in a cuvette for instrumental analysis (example): pipette 500 µl of HNO 3 2.5%( 4.1.1) pipette 500 µl of PSBs Page 6 of 10

mix the solution by pipetting several times (see 6 a). 6.2.3.1.3 Standard 1 : in a 5ml falcon tube (example): pipette 1.0 ml of HNO 3 2.5% (4.1.1) take off 20µl add 20µl of Pb (6.2.1.1) and 1.0 ml of Pool of Sample Blanks (PBSs) mix thoroughly pipette 1ml of the obtained solution in a cuvette for instrumental analysis. 6.2.3.1.4 Standards 2, 3, 4, 5: in a cuvette for instrumental analysis (example): pipette 500 µl of HNO3 2.5%(4.1.1) take off the amount of standard to be added (e.g. for standard 2, take off 20µl) add the calibration solution (e.g. for standard 2, add 20µl of Pb 0.25 mg/l (6.2.1.1)) add 500µl of Pool of Sample Blanks (PSBs) mix thoroughly by pipetting (see 6 a). 6.2.4 Sample Dilution 6.2.4.1 Minimum dilution 1:2: into a 1 ml cuvette for instrumental analysis (example): pipette 500µl of HNO3 2.5%(4.1.1) add 500µl of sample and mix thoroughly by pipetting (see 6 a). 6.2.4.2 Further dilution e.g. 1:10: into a 1 ml cuvette for instrumental analysis (example): pipette 400µl Pool of Sample Blanks (PSBs) add 100µl of sample pipette 500µl of HNO3 2.5% (4.1.1) and mix thoroughly by pipetting (see 6 a). 6.2.5 Drift Check Drift is checked by analyzing the second and the fourth standard: at the end of an analysis, if the number of samples analyzed is less than 8; after each series of 8 samples; at the end of an analysis, if more than 3 samples have been run after the last check. If the instrumental drift is higher than the maximum value set in the method, repeat the calibration curve and read the previous samples up to the last acceptable check. 6.2.6 Spectrometer Settings Optimize the instrument in accordance with the recommendation described in the internal procedures. The thermic program is reported in Annex 2. 7. CALCULATION Calculate the content, w, of the chemical element as mass fraction mg/kg as follows: w = D a V m 1000 where: D= dilution of the test solution before the instrumental determination a = is the concentration of the element in the test solution in μg/l Page 7 of 10

V = final volume of the solution in ml m = weight of the sample in g Calculate V as follows: V= (Pf-Pi)/d where: Pi = weight of the falcon empty tubes Pf = weight of the falcon tubes containing the final solution d = weight of 1 ml of the final solution 8. EXPRESSION OF RESULTS Express the final result as mean of three independent sample preparations 9. PARAMETERS OF THE EURL-CEFAO METHOD LoD and LoQ were determined using 21 aliquots of 5 different samples of honey purchased on the market. Repeatability was evaluated using a sample spiked with Cd and Pb: 10 aliquots were quantified twice on the same day, in two different analytical runs. The parameters obtained during the method development are summarized as follows: Parameter Cd Pb LoD (=3*SD) µg/kg 0.8 12.7 LoQ (=10*SD) µg/kg 2.7 42.3 RSDr % 1.4 1.7 The Instrumental Maximum Acceptable Drift was set at 7% for both the standards. Page 8 of 10

Annex 1: Instrumental Settings for Cd The annex is the instrumental program in paper form for Cd Page 9 of 10

Method Name: Cd Honey 2 Define Element Method Description : NH4H2PO4 3 g/l in Triton 0,05% Spectrometer Element : Cd Wavelength (nm) : 228.8 Slit Width (nm) : 0.7L Signal Type : AA - BG Measurement : Peak Area Settings Read Parameters Time (sec) : 3.0 Delay Time (sec) : 0.0 BOC Time (sec) : 2 Replicates... Same for All Samples : 2 Lamp Current Use value entered in Lamp Setup window Furnace Program Step Temp( C) Ramp Time Hold Time Internal Flow Gas Type 1 120 1 30 250 Normal 2 140 15 30 250 Normal 3 500 10 20 250 Normal 4 1500 0 3 0 Normal 5 2450 1 3 250 Normal Read Step : 4 Injection Temperature( C) : 20 No extra furnace cleanout. Furnace Autosampler Sample Volume : 20 ul Diluent Volume : 0 ul Diluent Location : 1 Matrix Modifiers #1 Volume : 5 ul Location : 20 Add to calibration blank and standards. Add to reagent blank and samples. #2 Volume : 0 ul Location : 1 Add to calibration blank and standards. Add to reagent blank and samples. Autosampler and Furnace Sequence Step Actions and Parameters A Pipet diluent + modifier1 + spike + sample/std B Run furnace steps 1 to end Page 1 09/09/2013 17:10:26

Method Name: Cd Honey 2 Pipet Speed... Take up : 100% Dispensing : 100% Calibration Equation and Units Equation : Method of Additions Calibrate Maximum Decimal Places : 3 Maximum Significant Figures : 4 Analyst-prepared additions. Calibration Units : ug/l Sample Units : ug/l Calibration Standard Concentrations ID Concentration A/S Loc Stock(uL) Diluent(uL) Calib Blank Blk 1 20 Addition 1 Addition 1 0.25 Addition 2 Addition 2 0.5 Addition 3 Addition 3 1 Addition 4 Addition 4 1.5 Addition 5 Addition 5 2 Initial Calibration Options When opening this method manually: Clear calibration curve(s) and construct a new calib curve. When using this method in a multimethod sequence: Start by constructing new calibration curves. Calibration Check Correlation coefficient checking is not enabled in this method. Recalibration Periodic recalibration is not enabled in this method. Analyze standards at end of analysis is not enabled in this method. Precision Checks Precision checking is not enabled in this method. Beyond Calibration Range Beyond calibration range checking is not enabled in this method. Page 2 09/09/2013 17:10:26

Method Name: Cd Honey 2 Matrix Recovery Matrix recovery checking is not enabled in this method. Automatic Recovery Automatic recovery checking is not enabled in this method. QC Sample Definition A/S Count as Subtract QC Sample ID Loc Sample Reagent Blank QC Sample Concentrations and Limits Schedule for QC Analyses After After QC Sample ID Init Cal Recal Periodic Freq At End Periodic Timing of Analyses Frequency... Same for all QC's : 1 Count : Samples Failure Actions for After-Calibration QC's Times to When All Additional QC Sample ID Retry QC Tries Fail Message Failure Actions for Periodic QC's Times to When All Additional QC Sample ID Retry QC Tries Fail Message Failure Actions for At-End QC's Times to When All Additional QC Sample ID Retry QC Tries Fail Message Maximum Retries After QC Failure After a group of standards or unknowns has been reanalyzed 1 times, then Continue Options Include in Results Display and Printed Log: Headers: Analytical Header Page 3 09/09/2013 17:10:26

Method Name: Cd Honey 2 Method Header (Short) * Sample Header (Short) Start each sample on a new page Sample Data Items: Summary Items: * Replicate Data Analysis List * Means and Statistics * Matrix Test Reports Transient Peak Plots (Last) * Calibration Summary * Calibration Curves Save with Results: * Transient Peak Profiles Remarks: MM: 3g/l fosf amm. in triton 0.05% Sample dilution 1:2 in HNO3 2.5% Page 4 09/09/2013 17:10:26

Annex 2: Instrumental Settings for Pb The annex is the instrumental program in paper form for Pb Page 10 of 10

Method Name: Pb Honey DD Define Element Method Description : Pb Honey DD Spectrometer Element : Pb Wavelength (nm) : 283.3 Slit Width (nm) : 0.7L Signal Type : AA - BG Measurement : Peak Area Settings Read Parameters Time (sec) : 5.0 Delay Time (sec) : 0.0 BOC Time (sec) : 2 Replicates... Same for All Samples : 2 Lamp Current Use value entered in Lamp Setup window Furnace Program Step Temp( C) Ramp Time Hold Time Internal Flow Gas Type 1 110 1 30 250 Normal 2 130 15 30 250 Normal 3 600 15 20 250 Normal 4 1700 0 5 0 Normal 5 2450 1 3 250 Normal Read Step : 4 Injection Temperature( C) : 20 No extra furnace cleanout. Furnace Autosampler Sample Volume : 20 ul Diluent Volume : 0 ul Diluent Location : 1 Matrix Modifiers #1 Volume : 5 ul Location : 20 Add to calibration blank and standards. Add to reagent blank and samples. #2 Volume : 0 ul Location : 1 Autosampler and Furnace Sequence Step Actions and Parameters A Pipet diluent + modifier1 + spike + sample/std B Run furnace steps 1 to end Pipet Speed... Take up : 100% Dispensing : 100% Page 1 09/09/2013 17:09:24

Method Name: Pb Honey DD Calibration Equation and Units Equation : Method of Additions Calibrate Maximum Decimal Places : 3 Maximum Significant Figures : 4 Analyst-prepared additions. Calibration Units : ug/l Sample Units : ug/l Calibration Standard Concentrations ID Concentration A/S Loc Stock(uL) Diluent(uL) Calib Blank Calib Blank 1 1 20 Addition 1 Addition 1 2.5 Addition 2 Addition 2 5 Addition 3 Addition 3 10 Addition 4 Addition 4 15 Addition 5 Addition 5 20 Initial Calibration Options When opening this method manually: Clear calibration curve(s) and construct a new calib curve. When using this method in a multimethod sequence: Start by constructing new calibration curves. Calibration Check Correlation coefficient checking is not enabled in this method. Recalibration Periodic recalibration is not enabled in this method. Analyze standards at end of analysis is not enabled in this method. Precision Checks Precision checking is not enabled in this method. Beyond Calibration Range Beyond calibration range checking is not enabled in this method. Matrix Recovery Page 2 09/09/2013 17:09:24

Method Name: Pb Honey DD Matrix recovery checking is not enabled in this method. Automatic Recovery Automatic recovery checking is not enabled in this method. QC Sample Definition A/S Count as Subtract QC Sample ID Loc Sample Reagent Blank QC Sample Concentrations and Limits Schedule for QC Analyses After After QC Sample ID Init Cal Recal Periodic Freq At End Periodic Timing of Analyses Frequency... Same for all QC's : 1 Count : Samples Failure Actions for After-Calibration QC's Times to When All Additional QC Sample ID Retry QC Tries Fail Message Failure Actions for Periodic QC's Times to When All Additional QC Sample ID Retry QC Tries Fail Message Failure Actions for At-End QC's Times to When All Additional QC Sample ID Retry QC Tries Fail Message Maximum Retries After QC Failure After a group of standards or unknowns has been reanalyzed 1 times, then Continue Options Include in Results Display and Printed Log: Headers: Analytical Header Method Header (Short) * Sample Header (Short) Page 3 09/09/2013 17:09:24

Method Name: Pb Honey DD Start each sample on a new page Sample Data Items: Summary Items: * Replicate Data Analysis List * Means and Statistics * Matrix Test Reports Transient Peak Plots (First) * Calibration Summary Calibration Curves Save with Results: * Transient Peak Profiles Remarks: Matrix modifier : 3g/l NH4H2PO4 + 0.25g/l Mg(NO3)2 in 0.05% TX; Samples diluition 1:2 in HNO3 2.5% Page 4 09/09/2013 17:09:24