Initial study - draft

Similar documents
METHOD OF IN-SITU MEASUREMENT OF THERMAL INSULATION PERFORMANCE OF BUILDING ELEMENTS USING INFRARED CAMERA

INFRARED (IR) THERMOGRAPHY MEASUREMENT OF U-VALUE Siliang Lu

QIRT th International Conference on Quantitative InfraRed Thermography

THE EFFECTS OF CALORIMETER TILT ON THE INWARD-FLOWING FRACTION OF ABSORBED SOLAR RADIATION IN A VENETIAN BLIND

The Electrodynamics of a Pair of PV Modules with Connected Building Resistance

USER MANUAL HFP01 & HFP03

Department of Energy Science & Engineering, IIT Bombay, Mumbai, India. *Corresponding author: Tel: ,

Experimental Investigation of Adiabatic Film Cooling Effectiveness and Heat Transfer Coefficients over a Gas Turbine Blade Leading Edge Configuration

Computational Modelling of the Impact of Solar Irradiance on Chemical Degradation of Painted Wall Hangings in an Historic Interior

Exergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness

LP NET. 1 About LP NET. 2 Working Principle. TEL r.a. FAX

CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT

Energy and Buildings

Chapter 2 HEAT CONDUCTION EQUATION

Chapter 2 HEAT CONDUCTION EQUATION

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

HEAT LOSS MEASUREMENTS ON PARABOLIC TROUGH RECEIVERS

Experimental Evaluation of Natural Heat Transfer in Façade Integrated Triangular Enclosures

VALIDATION OF REYNOLDS AVERAGED MODEL AND LARGE EDDY SIMULATION IN ACTUAL FLOOR HEATING ROOM. Hiroki Ono 1 and Koji Sakai 1

HEAT FLOW SENSORS MF-180 MF-180M MF-190 MF-200 INSTRUCTION MANUAL

Fig 1. Power Tower during Operation

Thermal Unit Operation (ChEg3113)

Determining of Thermal Conductivity Coefficient of Pressed Straw (Name of test)

Novel Flux Calibration Source. CORM 2007 David C. Gross May 10, 2007

LP PYRA Installation and Mounting of the Pyranometer for the Measurement of Global Radiation:

Experimental Performance and Numerical Simulation of Double Glass Wall Thana Ananacha

Preliminary Experimental Study on Heat Transfer Characteristics of Wall with Automatic Adjustment of Heat Transfer Coefficient

Characterizing the Performance of an Eppley Normal Incident Pyrheliometer

Available online at ScienceDirect. Energy Procedia 57 (2014 ) ISES Solar World Congress

ADVANCED ROOF COATINGS: MATERIALS AND THEIR APPLICATIONS

1D and 3D Simulation. C. Hochenauer

Determination of installed thermal resistance into a roof of TRISO-SUPER 12 BOOST R

Arctice Engineering Module 3a Page 1 of 32

Chapter 3: Steady Heat Conduction. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

TREES Training for Renovated Energy Efficient Social housing

Numerical Optimization of Heating for High- Speed Rotating Cup by Means of Multiphysics Modeling and its Experimental Verification

OPTIMIZATION of the GEOMETRY & MATERIAL of SOLAR WATER HEATERS.

Department of Mechanical Engineering ME 96. Free and Forced Convection Experiment. Revised: 25 April Introduction

Chapter 1: 20, 23, 35, 41, 68, 71, 76, 77, 80, 85, 90, 101, 103 and 104.

s tor bric Compensa Fa

ENSC 388. Assignment #8

Ordinary Level Physics Long Questions: TEMPERATURE AND HEAT

THERMAL TRANSMITTANCE OF MULTI-LAYER GLAZING WITH ULTRATHIN INTERNAL PARTITIONS. Agnieszka A. Lechowska 1, Jacek A. Schnotale 1

Chapter 1. Blackbody Radiation. Theory

University of New Mexico Mechanical Engineering Fall 2012 PhD qualifying examination Heat Transfer

MICROENCAPSULATED PHASE CHANGE MATERIALS (PCM) FOR BUILDING APPLICATIONS

Weather Stations. Evaluation copy. 9. Post live weather data on the school s web site for students, faculty and community.

EXPERIMENTAL STUDY ON A CASCADED PCM STORAGE RECEIVER FOR PARABOLIC DISH COLLECTOR

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Standard Test Method for Measuring the Steady-State Thermal Transmittance of Fenestration Systems Using Hot Box Methods 1

INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY

Thermal conductivity measurement of two microencapsulated phase change slurries

ARCH 348 BUILDING AND ENVIRONMENTAL SYSTEMS

Radiant Heating Panel Thermal Analysis. Prepared by Tim Fleury Harvard Thermal, Inc. October 7, 2003

MCS 7 Chia Laguna, Cagliari, Sardinia, Italy, September 11-15, 2011

Experimental Validation of Above-Floor Tube-and-Plate Radiant Floor Model

Application of the Multi-current Transient Hot-Wire Technique for Absolute Measurements of the Thermal Conductivity of Glycols

Group Research Projects

Aalborg Universitet. Publication date: Document Version Publisher's PDF, also known as Version of record

Introduction HMTTSC Nikolay Smirnov 1,*, Vladimir Tyutikov 1, and Vadim Zakharov 1

TEST OF MEASURED SOLAR HEAT GAIN VARIATION WITH RESPECT TO TEST SPECIMEN TILT

ME 4/549 Lab Assignment 5: Single Block Experiment Spring 2006 due 1 June 2006

V.Schmidt, P. Hamel. Radon in the Living Environment, April 1999, Athens, Greece

CHAPTER 4 THERMAL CONDUCTIVITY AND VISCOSITY MEASUREMENTS

Introduction to Blackbody Sources

Master School of Province de Liege -Industrial Engineer Department Nano-P.C.M.

Ohm's Law and Resistance

Test methods GRAPHENE- HEAT DISSIPATION SHEET GADIANT. Product Name: Gadiant Purpose: electrical and electronic equipment fever reduction

TEST METHOD FOR MEASURING INSULATION VALUES OF CRYOGENIC PIPES

Performance Assessment of PV/T Air Collector by Using CFD

Model 3024 Albedometer. User s Manual 1165 NATIONAL DRIVE SACRAMENTO, CALIFORNIA WWW. ALLWEATHERINC. COM

Energy flows and modelling approaches

MOISTURE TRANSPORT THROUGH

Behavior of Curtain Walls Heating Reduction of Buildings in Summer Situations or in Hot Climates

Solar Flat Plate Thermal Collector

Response function method

MERGING OF SHEET PLUMES IN TURBULENT CONVECTION

Comparison tests of cellular glass insulation for the development of cryogenic insulation standards

Documentation of the Solutions to the SFPE Heat Transfer Verification Cases

SUBJECT AREA(S): science, math, solar power, visible light, ultraviolet (UV), infrared (IR), energy, Watt, atmospheric conditions

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: NORTH EAST WINDOWS USA, INC.

WEATHER STATION FOR SOLAR FARM MONITORING

Cooling of Electronics Lecture 2

Phys2120 Spring 2017 Practice Exam 1. Chapters Name

GCSE SCIENCE HIGHER TIER PHYSICS 1. P.M. FRIDAY, 17 June minutes. Centre Number. Candidate Number. Surname. Other Names

Calculating the heat transfer coefficient of frame profiles with internal cavities

Indoor Testing of Solar Systems: A Solar Simulator for Multidisciplinary Research on Solar Technologies

A SIMPLE MODEL FOR THE DYNAMIC COMPUTATION OF BUILDING HEATING AND COOLING DEMAND. Kai Sirén AALTO UNIVERSITY

Examination Heat Transfer

Solar Energy Cooking with the Sun

Review: Conduction. Breaking News

Natural convective heat transfer in trapezoidal enclosure of box-type solar cooker

Sol-air thermometer measurement of heat transfer coefficient at building outdoor surfaces

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: NU VISTA WD, INC. SERIES/MODEL: Malibu 250 T TYPE: Fixed

PERFORMANCE ANALYSIS OF A SINGLE BASIN DOUBLE SLOPE PASSIVE SOLAR STILL

Customer: Ashton Industrial Sales Ltd. South Road, Harlow Essex CM20 2AR UNITED KINGDOM. Project/Customer: Profilex HM spacer

5. AN INTRODUCTION TO BUILDING PHYSICS

Determination of the Specific Heat Capacity of Graphite Using Absolute and Differential Methods Susanne Picard David Burns Philippe Roger BIPM

Effect of Periodic Variation of Sol-air Temperature on the Performance of Integrated Solar Collector Storage System

Experimental and Theoretical Evaluation of the Overall Heat Loss Coefficient of a Vacuum Tube Solar Collector

Transcription:

The department of Ecotechnology 2014-03-24 and Sustainable Building Engineering Itai Danielski Campus Östersund Tel: 063 165416 E post: itai.danielski@miun.se Measurements of heat transfer coefficient of external walls with different insulation materials This study has two main goals: (i) to compare the heat transfer coefficient of external walls with two different insulation materials: wood fibres and foam glass; and (ii) to evaluate the heat flux sensor as a tool for measuring heat transfer coefficient of buildings. Two case studies of detached houses were studied. Both are located in Juniskär, south of Sundsvall. The first case study is a wooden constructed detached house with wood fibre insulation material (Fig.1). The second case study is made of foam glass elements, which perform as insulation material covered by wooden panelling (Fig.2). Both buildings have similar insulation thickness in the external walls of about 300 mm. The wood fibres and foam glass have similar thermal conductivity; 0.041 W/(m K) and 0.039 W/(m K) respectively. These values were obtained from Åke Mård from koljern. Figure 1 Case study of detached house with wood fibre insulation material Figure 2 Case study of detached house with foam glass insulation material

The heat transfer coefficient (U) of buildings elements is a coefficient of proportionality between the heat flux and the temperature difference between the indoor and the outdoor (ΔT). The heat flux is the product, while the temperature difference is the driving force. The heat transfer coefficient could be determined by regression analysis if the heat flux is known for a range of temperature differences between the two sides of the building element. Measurements The heat transfer coefficient of building elements can be calculated from measured values of heat flux and ambient air temperatures at both sides of the element, i.e. indoor and outdoor temperatures. In this study, a heat flux sensor of type HFP01 Hukseflux was used. The sensor has a nominal sensitivity of 50 μv/wm 2, a working temperature range between 30 C to +70 C, and an expected typical accuracy of ±5%. The sensor was connected to a logger of type LI19 Hukseflux. The measurements started at 2013 02 22 18:00 and ended at 2013 03 18 08:00 with 15 minutes interval between readings. To obtain accurate measurement it was important to reduce the effects of external parameters to the minimum possible. In this study the following measures were taken: The heat flux was measured at the ground floor at the same height level in both case studies. The indoor temperature, in each case study, was measured at the same location as the heat flux. The heat flux measurements were done on the inner side of the north facing external wall in order to avoid the effects of direct solar radiation during day time. The walls were scanned with an infra red camera (Fleer T440) to avoid locations with wooden studs, pipes, electrical wiring or any other installations that could have an effect on the results. A location with uniform wall surface temperature was chosen in each of the case studies. The heat flux sensor was coated with a high heat conduction layer (dowcorning gel) before attaching it to the wall. The gel reduces the heat resistance between the sensor and the wall by reducing the amount of air cavities. A temperature sensor of type RHTemp1000 MadgeTech was used to measure the outdoor temperature. The working temperature of the sensor is between 40 C and 80 C, the temperature resolution is 0.1 C and temperature calibrated accuracy is ±0.5.The accuracy of the heat flux measurement can be affected by different parameters. A temperature sensor of type MicroRHTemp MadgeTech was used to measure the indoor temperature in each of the buildings. The working temperature of the sensor

is between 0 C and 60 C, the temperature resolution is 0.1 C and the temperature calibrated accuracy is ±0.5. The temperature sensor in each building was located at the same location as the heat flux sensor. RESULTS Temperature measurements During the measurement period the outdoor temperature ranged between 17 C and +9 C, as illustrated in Fig.3. The indoor temperature, in the wood fibre case study house, was found to be less stable with several high picks, and was, in average, 5.5 C lower in comparison to the foam glass case study house. Thus, the difference in ambient air temperature between the indoor and outdoor (ΔΤ) was lower and with more fluctuations in the wood fibre case study house. Figure 3 Measurements of the indoor and outdoor temperatures Thermal properties In Fig. 4 and Fig. 5, the measured heat flux values were plotted against the differences between indoor and outdoor ambient temperature for each case studies. The heat flux was found to increase with temperature differences, which was expected and the value of heat transfer coefficient, represented by the tangent of the trend line, was determined by a linear regression including all the measured values. The heat transfer coefficient of the wall element in the wood fibre case study was found to be 0.1888 W/(m 2 K), which is higher by 38% in comparison to 0.1371 W/(m 2 K) as found in the foam glass case study house (fig.4 and fig.5). The values of the thermal conductivity (k) of the insulation material in each of the buildings were calculated from the measured heat transfer coefficient (U), by knowing the wall construction in each case study (according to Fig.1 and Fig.2), and by using Eq.1, with h as the convection heat transfer coefficient for air. According to the results, the thermal conductivity of the foam glass case study house found to be 0.042 W/(m K), which is only 2% higher than the expected value. The thermal conductivity of the wood fibre case study house found to be 0.059 W/(m K), which is higher by 51% than the expected value.

Eq.1 Figure 4 The heat flux and temperature difference measured at the wood fibre case study house Figure 5 The heat flux and temperature difference measured at the foam glass case study house Uncertainty In a steady case condition, the heat flux is expected to follow a linear trend line as the temperature difference changes. However, with frequent change in indoor and outdoor thermal conditions, steady state is seldom attained. Thus, large span of heat flux was measured for each ΔT, and relatively low coefficient of determination (R 2 ) obtained; 0.1883 and 0.2695, respectively for the wood fibre and foam glass case study houses. The low R 2 indicates that large uncertainty exists in determining the value of the heat transfer coefficient, and therefore its value should be taken with caution. Conclusions In this study the heat transfer coefficient of a building element (external wall) was determine by measuring the heat flux through the element and the difference in ambient air temperature between its both sides. This seems to be possible but there are three disadvantages to this method: 1. Several weeks might be needed to obtain sufficient sample size of heat flux measurement. 2. The heat flux measurement is a local measurement and does not represent the overall heat transfer coefficient of an entire building element. The measurement locations that were chosen were homogenous. Thus, the effect of wooden studs, corners, or other irregularities in the building elements, which could have a significant effect on the overall heat transfer coefficient, and are not considered in this study.

3. The results found to have large uncertainties as the indoor and outdoor thermal conditions changes frequently and a steady state heat flux, through the building element, is not a constant conditions. 4. The measured values of the heat transfer coefficient and the thermal conductivity for the foam glass case study house were in the expected range. However for the wood fibre case study house the measured values were higher than expected, as listed in Table 1 below. The causes for these high values need additional investigation. Table 1. Comparison between the calculated (expected) and measured values Thermal conductivity Heat transfer coefficient Case study Expected Measured Calculated Measured building W/(m K) W/(m K) W/(m 2 K) W/(m 2 K) Wood fibre 0.039 1 0.059 2 0.122 0.1888 Foam glass 0.041 1 0.042 2 0.133 0.1371 1 Values obtained from Åke Mård from the Koljern Company. 2 Values calculated from the measured values of the heat transfer coefficient