High-speed inline holographic Stokesmeter imaging

Similar documents
Waveplate analyzer using binary magneto-optic rotators

Transmission matrices of random media: Means for spectral polarimetric measurements

Polarimetry of Light Using Analysis of the Nonlinear Voltage-Retardance Relationship for Liquid-Crystal Variable Retarders

Optimizing imaging polarimeters constructed with imperfect optics

Polarized Light. Second Edition, Revised and Expanded. Dennis Goldstein Air Force Research Laboratory Eglin Air Force Base, Florida, U.S.A.

Polarization properties of corner-cube retroreflectors: Theory and experiment

Mueller Matrix Polarimetry: A Powerful Tool for Nanostructure Metrology

Scattering of light from quasi-homogeneous sources by quasi-homogeneous media

Stokes polarimeter optimization in the presence of shot and Gaussian noise

17. Jones Matrices & Mueller Matrices

Optimization of Mueller matrix polarimeters in the presence of error sources

POLARIZATION OF LIGHT

In-line broadband 270 degrees (3 lambda/4) chevron four-reflection wave retarders

Polarization algebra: decomposition of depolarizing Mueller matrices

Thin Solid Films 519 (2011) Contents lists available at ScienceDirect. Thin Solid Films. journal homepage:

Complex refractive-index measurement based on Fresnel s equations and the uses of heterodyne interferometry

PMARIZED LI6HT FUNDAMENTALS AND APPLICATIONS EBWABD COLLETT. Measurement Concepts, Inc. Colts Neck, New Jersey

3.4 Elliptical Parameters of the Polarization Ellipse References

ECE 185 ELECTRO-OPTIC MODULATION OF LIGHT

Ultra-narrow-band tunable laserline notch filter

Scattering of Poincaré beams: polarization speckles

Intuitive interpretation of Mueller matrices of transmission. John Freudenthal Hinds Instruments, Inc.

Mueller matrix approach for determination of optical rotation in chiral turbid media in backscattering geometry

Quasi index matching for minimum reflectance at a dielectric-conductor interface for obliquely incident p- and s-polarized light

Stabilization of the channeled spectropolarimeter. by self calibration

Lab #13: Polarization

Backscattering enhancement of light by nanoparticles positioned in localized optical intensity peaks

BISTABLE twisted nematic (BTN) liquid crystal displays

Physics I Keystone Institute Technology & Management Unit-II

Recovering the absolute phase maps of two fringe patterns with selected frequencies

Polarization of Light and Birefringence of Materials

Lecture 8: Polarimetry 2. Polarizers and Retarders. Polarimeters. Scattering Polarization. Zeeman Effect. Outline

Light for which the orientation of the electric field is constant although its magnitude and sign vary in time.

ECEN 4606, UNDERGRADUATE OPTICS LAB

Polarization. Polarization. Physics Waves & Oscillations 4/3/2016. Spring 2016 Semester Matthew Jones. Two problems to be considered today:

Novel method for ultrashort laser pulse-width measurement based on the self-diffraction effect

F 44 Normal Zeeman Effect

16. More About Polarization

Incorporation of polar Mellin transform in a hybrid optoelectronic correlator for scale and rotation invariant target recognition

Near-perfect modulator for polarization state of light

Liquid refractometer based on immersion diffractometry

Lecture 5: Polarization. Polarized Light in the Universe. Descriptions of Polarized Light. Polarizers. Retarders. Outline

Optical Simulation Analysis of a Geometrical-phase-based. Nulling Interferometer

Parallel fractional correlation: implementation

Extinction ratio measurements on high purity linear polarizers

Additive Gaussian Noise in Polarimetric Imaging Systems

Best Student Paper Award

Chapter 2 Advanced Mueller Ellipsometry Instrumentation and Data Analysis

Polarimetry in the E-ELT era. Polarized Light in the Universe. Descriptions of Polarized Light. Polarizers. Retarders. Fundamentals of Polarized Light

PMD Compensator and PMD Emulator

Experimental generating the partially coherent and partially polarized electromagnetic source

Solar Magnetic Fields Jun 07 UA/NSO Summer School 1

Polarimetry Techniques. K. Sankarasubramanian ISRO Satellite Centre Bangalore India

Solar irradiance measurement up to 2500nm with the Arcoptix FT-NIR

Mueller Coherency matrix method for contrast image in tissue polarimetry

Quarter wave plates and Jones calculus for optical system

Polarization of Light

Observation of accelerating parabolic beams

Phase constraint for the waves diffracted by lossless symmetrical gratings at Littrow mount

Analysis of diffraction efficiency of a holographic coupler with respect to angular divergence

Beyond polarization microscopy: Mueller matrix microscopy

Spectral Degree of Coherence of a Random Three- Dimensional Electromagnetic Field

Visualization of polarization state and its application in Optics classroom teaching

Broadband IR polarizing beam splitter using a subwavelength-structured one-dimensional photonic-crystal layer embedded in a high-index prism

Degree of polarization in laser speckles from turbid media: Implications in tissue optics

Polarization errors associated with zero-order achromatic quarter-wave plates in the whole visible spectral range

Pre-lab Quiz/PHYS 224. Your name Lab section

Fundamentals of Photoelasticity

GRATING CLASSIFICATION

Let us consider a typical Michelson interferometer, where a broadband source is used for illumination (Fig. 1a).

Polarization control and sensing with two-dimensional coupled photonic crystal microcavity arrays. Hatice Altug * and Jelena Vučković

Satellite Remote Sensing SIO 135/SIO 236. Electromagnetic Radiation and Polarization

Internal magnetic field measurement in tokamak plasmas using a Zeeman polarimeter

Coherent Superposition of Mueller-Jones States: Synthesizing Mueller Matrices with an Ellipsometer

Ellipsometry. Introduction. Measurement Principles

First observations of the second solar spectrum with spatial resolution at the Lunette Jean Rösch

Signal Level Considerations For Remote Diffuse Reflectance Analysis

Lecture 4: Polarimetry 2. Polarizers and Retarders. Polarimeters. Scattering Polarization. Zeeman Effect. Outline

On-axis joint transform correlation based on a four-level power spectrum

Department of Physics and Astronomy, Trent University, 1600 West Bank Drive, Peterborough, Ontario K9J 7B8, Canada

Direct measurement of electric-field-induced birefringence in a polymer-stabilized blue-phase liquid crystal composite

Efficient sorting of orbital angular momentum states of light

Study of the Composition and Spectral Characteristics of a HDG-Prism Disperse System (GRISM) by Refractive Index Phase Matching

J.-C. Zhang, Y.-Z. Yin, and J.-P. Ma National Laboratory of Antennas and Microwave Technology Xidian University Xi an, Shaanxi , P. R.

Brewster Angle and Total Internal Reflection

APPLICATION OF BILAYER ANISOTROPIC STRUC- TURES FOR DESIGNING LOW-PASS FILTERS AND PO- LARIZERS

Investigation of the noise-like structures of the total scattering cross-section of random media

Experiment O-2. The Michelson Interferometer

Generating Bessel beams by use of localized modes

Optical Systems Program of Studies Version 1.0 April 2012

Polarimetry Of Random Fields

Imaging of vibrating objects using speckle subtraction

Diffraction light modulator based on transverse electro-optic effect in short-pitch ferroelectric liquid crystals

Chiroptical Spectroscopy

Vector diffraction theory of refraction of light by a spherical surface

To determine the wavelengths of light emitted by a mercury vapour lamp by using a diffraction grating.

Determination of absorption coefficient by digital holographic measurement of optical excitation

DESIGN OF A FULLY AUTOMATED POLARIMETRIC IMAGING SYSTEM FOR REMOTE CHARACTERIZATION OF SPACE MATERIALS. A Thesis. Presented to

beam (as different VSP One element from 400 to 1500nm diffraction, No segments

Projection-invariant pattern recognition with a phase-only logarithmic-harmonic-derived filter

Transcription:

High-speed inline holographic Stokesmeter imaging Xue Liu, 1 Alexander Heifetz, 1, Shih C. Tseng, 4 and M. S. Shahriar 1,, * 1 Department of Electrical Engineering and Computer Science, Northwestern University, Evanston, Illinois 6008, USA Department of Physics and Astronomy, Northwestern University, Evanston, Illinois 6008, USA Nuclear Engineering Division, Argonne National Laboratory, Argonne, Illinois 6049, USA 4 Digital Optical Technologies, Inc., Rolling Meadows, Illinois 60008, USA *Corresponding author: shahriar@northwestern.edu Received 1 February 009; revised May 009; accepted 6 May 009; posted 1 June 009 (Doc. ID 10549); published 1 July 009 We demonstrate a high-speed inline holographic Stokesmeter that consists of two liquid crystal retarders and a spectrally selective holographic grating. Explicit choices of angles of orientation for the components in the inline architecture are identified to yield higher measurement accuracy than the classical architecture. We show polarimetric images of an artificial scene produced by such a Stokesmeter, demonstrating the ability to identify an object not recognized by intensity-only imaging systems. 009 Optical Society of America OCIS codes: 110.5405, 090.890. 1. Introduction Polarization imaging takes advantage of polarization-sensitive reflection of light from different media. It has been used for a variety of applications, including vegetation mapping, pollution monitoring, geological surveys, medical diagnostics, computer vision, and scene discrimination [1 5]. An arbitrary polarization state of light can be represented by the Stokes vector, which is defined in terms of transverse components E x and E y of the electric field: 0 1 0 I he x E xiþhe y E 1 yi SðτÞ B Q C @ U A B he x E xi he y E yi C @ he x E yiþhe y E xi A ; V ihe x E yi ihe y E xi ð1þ where the brackets imply averaging over an observation time of τ. Here I is the overall intensity, Q denotes the intensity difference between vertical and horizontal linear polarizations, U represents the intensity difference between linear polarizations 000-695/09/1980-06$15.00/0 009 Optical Society of America at þ45 and 45, and V is the intensity difference between left and right circular polarizations. Measurement of the polarization state of the scattered light is often accomplished with a Stokesmeter that typically consists of several passive polarizationsensitive optical components and an intensity detector. A Mueller matrix is used to describe mathematically how the optical components of the Stokesmeter change the polarization state of the transmitted light [6,]. The net Mueller matrix of the Stokesmeter is given by the ordered product of the Mueller matrices of the individual optical elements. The classical Stokesmeter consists of a quarterwave plate (QWP) and a linear polarizer (LP) [8] and requires the QWP to be inserted and removed between various readings. Consequently, the speed of the system is greatly limited. This problem can be circumvented by using a pair of liquid crystal retarders (LCRs) in series with a polarizer. Such an architecture, capable of high-speed inline Stokesmetry, has been investigated theoretically [9] as well as experimentally [10 1]. Here we describe and demonstrate a variation of this architecture in which the polarizer is replaced by a polarization-sensitive holographic grating. For a given wavelength of 1 July 009 / Vol. 48, No. 19 / APPLIED OPTICS 80

illumination, the holographic grating is essentially equivalent to the conventional polarizer. However, it has the added capability of spectral multiplexing. By tilting the angle of the grating, it is possible to select a narrow spectral band of the input light. Thus, in effect, this system can be used to combine spectrally multiplexed imaging with Stokesmetric imaging in high-speed inline architecture. Previously, we demonstrated other types of holographic Stokesmeter [1 15]. However, the version demonstrated here is distinctly different from the previous versions. Specifically, there is no need to split the input beam into two parts in this architecture, thus making it much easier to perform Stokesmetric imaging. We demonstrate the ability of such a device to identify an object not recognizable through intensity-only imaging by analyzing the content of Stokesmetric images. In Section we briefly recall the operation of a classical Stokesmeter. In Section we review the architecture of an inline Stokesmeter and identify parameters that optimize the accuracy. In Section 4 we describe a LCR-based Stokesmeter constructed with polarization-sensitive holographic gratings. In Section 5 we present the experimental results that verify the increased accuracy of the inline architecture for the condition identified in Section. In Section 6 we demonstrate polarimetric imaging of an artificial scene with the inline holographic Stokesmeter.. Classical Stokesmeter Architecture The classical method to measure the Stokes parameters is illustrated in Fig. 1. It consists of a removable QWP and a rotating LP. The first three measurements of the transmitted intensity, denoted as I 1, I, and I, are carried out with the QWP removed, while the transmission axis of the LP is rotated clockwise (when looking in the direction of the beam propagation) to 0, 90, and 45, respectively. I 4 denotes the measured intensity after inserting the Fig. 1. Classical Stokesmeter with a removable QWP and a rotating LP. 1 1 0 0 A ¼ 1 6 1 1 0 0 4 1 0 1 05 : ðþ 1 0 0 1 Stokes vector S is given by S ¼ A 1 I.. Inline Stokesmeter Figure shows the inline Stokesmeter akin to what was presented by Ambirajan and Look [16]. In this architecture, the QWP and the LP are rotated simultaneously for each measurement, which allows for higher operational speed than the classical Stokesmeter because no removal or insertion of the QWP is required. For an input light beam with Stokes vectors S ¼½I; Q; U; VŠ T transmitted through the QWP rotated at an angle β i followed by the LP rotated at an angle α i, the Stokes vector of output beam S 0 ¼ ½I 0 ; Q 0 ; U 0 ; V 0 Š T is S 0 ¼ M S; ð4þ where M ¼ M LP M QWP equals the product of the Mueller matrices of the QWP and the LP [1]. Using the well-known Mueller matrices for a QWP and a LP, the following relation is obtained: I 0 1 cos β i cos ðα i β i Þ sin β i cos ðα i β i Þ sin ðα i β i Þ I 6 Q 0 4 U 0 5 ¼ 1 6 cos α i cos α i cos β i cos ðα i β i Þ cos α i sin β i cos ðα i β i Þ cos α i sin ðα i β i Þ 6 Q 4 sin α i sin α i cos β i cos ðα i β i Þ sin α i sin β i cos ðα i β i Þ sin α sin ðα i β i Þ 54 U 5 : ð5þ V 0 0 0 0 0 V QWP with the fast axis at 0 and the LP oriented at 45. The system can be represented by I ¼ A S; ðþ where I ¼½I 1 ; I ; I ; I 4 Š T, S is the input Stokes vector, and A is defined as the measurement matrix. The computed elements of A are given by The intensity observed by detector I 0 is given by I 0 ðα i ; β i Þ¼ 1 ½I þ Q cos β i cos ðα i β i Þ þ U sin β i cos ðα i β i ÞþV sin ðα i β i ÞŠ: ð6þ 804 APPLIED OPTICS / Vol. 48, No. 19 / 1 July 009

To determine the four Stokes parameters, four measurements of transmitted intensity I 0 are taken with different combinations of α i and β i, yielding the equation I ¼ A IL S, where AIL is the measurement matrix for this system given by ϕ ¼ π, whereas the phase retardation produced by LCR1 remains π. The measurement matrix for such a system, as calculated according to the first row of the Mueller matrix in Eq. (8), is found to be 1 cos β A IL ¼ 1 1 cos ðα 1 β 1 Þ sin β 1 cos ðα 1 β 1 Þ sin ðα 1 β 1 Þ 1 cos β 6 cos ðα β Þ sin β cos ðα β Þ sin ðα β Þ 4 1 cos β cos ðα β Þ sin β cos ðα β Þ sin ðα β Þ 5 : ðþ 1 cos β 4 cos ðα 4 β 4 Þ sin β 4 cos ðα 4 β 4 Þ sin ðα 4 β 4 Þ The determinant of measurement matrix ja IL j governs in part the accuracy of the measurement process. We have carried out a systematic tabulation of ja IL j as a function of angles α i and β i and determined that ja IL j max ¼ 0:184. Note that this value is larger than jaj ¼0:15 for the conventional Stokesmeter. We found that more than one possible combination yields this maximum value of ja IL j, as shown in Table 1. Explicit choices of parameters in this form have not been reported previously, to the best of our knowledge. The Stokesmeter described above can be realized with components that are rotated mechanically. Alternatively, it is possible to construct a system with two voltage-controlled LCRs along with a LP at a fixed orientation [15,16,18]. Free from any mechanical motion, this device can easily achieve the video-rate operation. Figure shows the basic schematic diagram of such a Stokesmeter. The incident light propagates through LCR1 and LCR (fast axis rotated by π 8 ) followed by a LP with the transmission axis oriented at π 4. The Mueller matrix for this system is 1 0 1 0 A ¼ 1 6 1 0 0 1 4 1 0 1 05 : ð9þ 1 1 0 0 The determinant of the measurement matrix is jaj ¼ 0:15 for the particular implementation shown in Eq. (9). We found that this is the highest determinant achievable with this architecture. With the LCR (from Meadowlark, Incorporated) used in our current setup, it takes approximately 0 ms to complete the full circle of four measurements, enabling it to be operated at a video-rate speed. 4. Inline, Spectrally Selective Holographic Stokesmeter The architecture described in Fig. makes use of a conventional polarizer. As an alternative, such a polarizer can be replaced by a holographic grating designed to work as a spectrally selective polarizer. This architecture is illustrated schematically in π M ¼ M LP M 4 LCR ϕ ; π M 8 LCR1 ðϕ 1 Þ ¼ 1 1 1 ð1 cos ϕ 1 Þ cos ϕð1 þ cos ϕ p Þ ffiffi sin ϕ 1 1 sin ϕ sin ϕð1 þ cos ϕ p Þþ ffiffi cos ϕ 1 sin ϕ 6 0 0 0 0 4 1 1 ð1 cos ϕ 1 Þ cos ϕð1 þ cos ϕ p Þ ffiffi sin ϕ 1 1 sin ϕ sin ϕð1 þ cos ϕ p Þþ ffiffi cos ϕ 1 sin ϕ 5 ; ð8þ 0 0 0 0 where ϕ 1 and ϕ denote the phase retardations produced by LCR1 and LCR, respectively. In the first three measurements, ϕ 1 is set to 0, π, and π consecutively, whereas ϕ is kept at 0. In the fourth measurement, the voltage on LCR is adjusted so that Fig. 4. To replace the LP oriented at 45 in the Stokesmeter demonstrated in Fig., the hologram is written to have a polarization-selective diffraction efficiency η such that η ¼ η 0 cos ðθ π 4Þ, where θ is the angle of the input polarization with respect to the 1 July 009 / Vol. 48, No. 19 / APPLIED OPTICS 805

Fig.. Inline automatic Stokesmeter with a rotating QWP and a rotating LP. Table 1. Four Sets of Combinations of QWP and LP Angles that Yield High ja IL j Values α 1 β 1 α β α β α 4 β 4 ja IL j 0 60 15 0 45 45 90 15 0.184 0 60 15 0 60 60 90 15 0.184 0 5 0 0 5 90 90 0 0.184 0 5 45 45 5 90 90 0 0.184 vertical axis with η 0 close to unity. Such a grating can easily be written, as discussed in Ref. [1]. As shown in Ref. [15], this grating is also spectrally selective. For a given angle of incidence, only light in a very narrow band (Δλ 1 nm for a grating thickness of 1 mm) undergoes diffraction. Within this band, this device is then equivalent to the Stokesmeter discussed in Section. Furthermore, by tilting its angular orientation, we can select a different band of light. Therefore, such a Stokesmeter is able to perform high-speed spectrally multiplexed inline Stokesmetric imaging. 5. Measuring the Stokes Vector In Section we identified optimum operating conditions for the inline Stokesmeter for both the mechanical and the LCR-based versions. To test the validity of these parameters, we carried out measurement of the Stokes parameters using an inline Stokesmeter Fig. 4. Schematic diagram of the inline, spectrally selective holographic Stokesmeter. and compared the results with those obtained using classical architecture. For both architectures, we studied three different polarization states of light: (a) linear 45 polarized light, (b) linear horizontally polarized light, and (c) right circularly polarized light. As shown in Fig. 5, compared with the measurement made by the classical Stokesmeter, the Stokes parameters measured by the inline architecture are closer to the theoretical value for all three cases. We define the accuracy of the measurement as follows: ε ¼ 1 S meas S theo 100%; ð10þ I theo where S meas and S theo stand for measured and theoretical values of Stokes parameters (I, Q, U, and V). I theo stands for the theoretical value of the intensity that is normalized to unity in our calculation. The average accuracy of the measurements done by the inline Stokesmeter is improved from 94.14% of the conventional method to 98.85%, whereas the system error remains nearly unchanged (approximately 0.8%). The possible sources of this residual error include the imperfection of the HWP and the LP, the imprecision in orienting the optical components, and the inherent intensity noise in the detection process. Fig.. High-speed inline Stokesmeter with two LCRs and a LP. 806 APPLIED OPTICS / Vol. 48, No. 19 / 1 July 009

Fig. 5. (Color online) Comparison of the Stokes parameters measured by the inline Stokesmeter and the classic Stokesmeter: (a) linear 45 polarized light, (b) linear horizontally polarized light, (c) right circularly polarized light. Fig. 6. (Color online) Polarization imaging for a set of objects with various polarization properties. The objects are illuminated by left circularly polarized light. 6. Polarization Imaging with the Inline Holographic Stokesmeter We used the inline automatic holographic Stokesmeter illustrated in Fig. 4 to analyze the polarization images for an artificial scene. The tested objects of different polarimetric properties include leaves, sandpaper, and different types of metal. We purposely attached a transparent adhesive tape to one piece of metal in the center of the scene to form the shape of the letter K. The objects were illuminated by left circularly polarized light. The reflection is analyzed by the inline holographic Stokesmeter. Since the attached tape does not change the reflectivity of the metal significantly, it cannot be easily identified in the camera view as shown in the first frame of Fig. 6. However, when the Stokes vector of light reflected by the scene is analyzed by the inline Stokesmeter from the images that contain only the left and right circularly polarized light (V =V þ ), the letter K shaped by the tape can be easily identified in the complex scenery that is due to the different polarimetric properties of the tape and the surroundings.. Conclusion To summarize, we have presented an inline holographic Stokesmeter consisting of two liquid crystal retarders and a spectrally selective holographic grating capable of operation at the video-frame rate. We also identified explicit choices of angles of orientation for the components in the inline architecture to yield higher accuracy of measurements than the classical architecture. The polarimetric images of an artificial scene produced by such a Stokesmeter show the ability to identify an object indiscernible by conventional intensity imaging systems. This research is supported in part by United States Air Force Office of Scientific Research (USAFOSR) grant FA9550-06-1-04, Office of Naval Research (ONR) contract N00014-0-M-01, and Department of Energy (DOE) grant DE-AC0-06CH115. Reference 1. L. J. Denes, M. Gottlieb, B. Kaminsky, and D. Huber, Spectropolarimetric imaging for object recognition, Proc. SPIE 40, 8 18 (1998). 1 July 009 / Vol. 48, No. 19 / APPLIED OPTICS 80

. T. Nee and S. F. Nee, Infrared polarization signatures for targets, Proc. SPIE 469, 1 41 (1995).. P. J. Curran, Polarized visible light as an aid to vegetation classification, Remote Sens. Environ. 1, 491 499 (198). 4. L. D. Travis, Remote sensing of aerosols with the earthobserving scanning polarimeter, Proc. SPIE 14, 154 164 (199). 5. M. J. Duggin, Imaging polarimetry in scene element discrimination, Proc. SPIE 54, 108 11 (1999). 6. S.-Y. Lu and R. A. Chipman, Interpretation of Mueller matrices based on polar decomposition, J. Opt. Soc. Am. A 1, 1106 111 (1996).. J. S. Baba, J.-R. Chung, A. H. DeLaughter, B. D. Cameron, and G. L. Cote, Development and calibration of an automated Mueller matrix polarization imaging system, J. Biomed. Opt., 41 49 (00). 8. D. Goldstein, Polarized Light, nd ed. (CRC Press, 00). 9. J. M. Bueno, Polarimetry using liquid-crystal variable retarders: theory and calibration, J. Opt. A Pure Appl. Opt., 16 (000). 10. A. De Martino, E. Garcia-Caurel, B. Laude, and B. Drévillon, Optimized Mueller polarimeter with liquid crystals, Opt. Lett. 8, 616 618 (00). 11. B. Laude-Boulesteix, A. De Martino, B. Drévillon, and L. Schwartz, Mueller polarimetric imaging system with liquid crystals, Appl. Opt. 4, 84 8 (004). 1. F. Goudail, P. Terrier, Y. Takakura, L. Bigué, F. Galland, and V. DeVlaminck, Target detection with a liquid-crystal-based passive Stokes polarimeter, Appl. Opt. 4, 4 8 (004). 1. M. S. Shahriar, J. T. Shen, R. Tripathi, M. Kleinschmit, T.-W. Nee, and S.-M. F. Nee, Ultrafast holographic Stokesmeter for polarization imaging in real time, Opt. Lett. 9, 98 00 (004). 14. J.-K. Lee, J. T. Shen, and M. S. Shahriar, Demonstration of a spectrally scanned holographic Stokesmeter, Opt. Commun., 6 66 (00). 15. T.-W. Nee, S.-M. F. Nee, M. W. Kleinschmit, and M. S. Shahriar, Polarization of holographic grating diffraction. II. Experiment, J. Opt. Soc. Am. A 1, 5 59 (004). 16. A. Ambirajan and D. C. Look, Jr., Optimum angles for a polarimeter: part I, Opt. Eng. 4, 1651 1655 (1995). 1. E. Collett, Polarized Light: Fundamentals and Applications (Marcel Dekker, 199). 18. A. Ambirajan and D. C. Look, Jr., Optimum angles for a polarimeter: part II, Opt. Eng. 4, 1656 1659 (1995). 808 APPLIED OPTICS / Vol. 48, No. 19 / 1 July 009