Amplified electrochemiluminescent immunosensing using apoferritin-templated poly(ethylenimine) nanoparticles as co-reactant

Similar documents
Ultrasensitive Immunoassay Based on Pseudobienzyme. Amplifying System of Choline Oxidase and Luminol-Reduced

Electrochemiluminescence detection of near single DNA molecule with quantum dots-dendrimer nanocomposite for signal amplification

Supporting Information

Electronic Supplementary Information. for. Discrimination of dopamine from ascorbic acid and uric acid on thioglycolic. acid modified gold electrode

Spectrum-resolved Dual-color Electrochemiluminescence Immunoassay for Simultaneous Detection of Two Targets with Nanocrystals as Tags

Supporting Information

Supplementary Information

Electronic Supplementary Information

Electrogenerated Upconverted Emission from Doped Organic Nanowires

Hollow AuPt alloy nanoparticles as enhanced immunosensing platform for. multiple analytes detection

Supplementary Material

Supporting Information

Electronic Supplementary Information. Novel multifunctionalized. peryleneteracarboxylic/amines supramolecules for. electrochemical assay

Electronic Supplementary Material (ESI) for Chemical Communications This journal is The Royal Society of Chemistry 2011

In a typical routine, the pristine CNT (purchased from Bill Nanotechnology, Inc.) were

Chemiluminescence excited photoelectrochemistry using graphene-quantum dots nanocomposite for biosensing

Electronic Supplementary Information. Microwave-assisted, environmentally friendly, one-pot preparation. in electrocatalytic oxidation of methanol

Supporting Information

Three Dimensional Nano-assemblies of Noble Metal. Nanoparticles-Infinite Coordination Polymers as a Specific

Electronic Supplementary Information

Electronic Supplementary Information

Protocol for Coating QD-COOH on glass slides Chris Ochs 19/09/12 Modified by Kathy Lu 2/27/2013

Electronic supplementary information

Nanomaterials and Chemistry Key Laboratory, Wenzhou University, Wenzhou, (P. R. China).

Digitized single scattering nanoparticles for probing molecular binding

Supporting Information. Selective detection of trace amount of Cu 2+ using semiconductor nanoparticles in photoelectrochemical analysis

mediated chemiluminescence for hydrogen peroxide and glucose

Spherotech, Inc Irma Lee Circle, Unit 101, Lake Forest, Illinois PARTICLE COATING PROCEDURES

A highly sensitive and label-free electrochemiluminescence immunosensor for beta 2-microglobulin

Supporting Information

Supporting information

Supplementary Information. Seeding Approach to Noble Metal Decorated Conducting Polymer Nanofiber Network

Multiply twinned Pt Pd nanoicosahedrons as highly active electrocatalyst for methanol oxidation

Encapsulation of enzyme in metal ion-surfactant nanocomposites for

Pt-Ni alloyed nanocrystals with controlled archtectures for enhanced. methanol oxidation

N-doped Carbon-Coated Cobalt Nanorod Arrays Supported on a Titanium. Mesh as Highly Active Electrocatalysts for Hydrogen Evolution Reaction

Supporting information:

Structural effects on catalytic activity of carbon-supported magnetite. nanocomposites in heterogeneous Fenton-like reactions

Electrocatalysis by Subcellular Liver Fractions Bound to Carbon Nanostructures for Stereoselective Green Drug Metabolite Synthesis

Highly Open Rhombic Dodecahedral PtCu Nanoframes

Chapter 2. Materials and Methods

Spatial-Resolved Photoelectrochemical Biosensing Array Based

Electronic Supplementary Information

Enhancement of the electrocatalytic activity of Pt nanoparticles in oxygen reduction by chlorophenyl functionalization

Hybrid Gold Superstructures: Synthesis and. Specific Cell Surface Protein Imaging Applications

DNA Labeling Generates a Unique Amplification Probe. HIV-1 p24 Antigen

Supporting Information

Pt-Cu Hierarchical Quasi Great Dodecahedrons with Abundant

Investigation of DNA methylation by direct electrocatalytic oxidation

A stable dual-functional system of visible-light-driven Ni(II) reduction to a nickel nanoparticle catalyst and robust in situ hydrogen production

Bismuthoxyiodide Nanoflakes/Titania Nanotubes. Arrayed p-n Heterojunction and Its Application for. Photoelectrochemical Bioanalysis

enzymatic cascade system

Electronic Supplementary Information

Supporting Information

Supporting Information

Shape-selective Synthesis and Facet-dependent Enhanced Electrocatalytic Activity and Durability of Monodisperse Sub-10 nm Pt-Pd Tetrahedrons and Cubes

Supplementary Information:

1 Electronic Supplementary Information. 3 SERS-based immunoassay on 2D-arrays of core-shell nanoparticles: influence

Boron-doped graphene as high-efficiency counter electrode for dye-sensitized solar cells

Determination of Electron Transfer Number for Oxygen Reduction Reaction: from Theory to Experiment

Electronic Supplementary Information

Electronic Supplementary Information. Facile synthesis of polypyrrole coated copper nanowire: new concept to engineered core-shell structures

Supplementary Information

Electronic Supplementary Information. Hydrogen Evolution Reaction (HER) over Electroless- Deposited Nickel Nanospike Arrays

Supporting Information. Single Particle Detection by Area Amplification Single Wall Carbon Nanotube Attachment to a Nanoelectrode

Controllable Preparation of Metal Nanoparticle/Carbon Nanotube Hybrids as Efficient Dark Field Light Scattering Agents for Cell Imaging

Supplementary Material

Supporting Information

Tetraethyl orthosilicate (TEOS, 99 %), resorcinol, formalin solution (37 wt. %),

Electronic Supplementary Information (ESI )

Controlled self-assembly of graphene oxide on a remote aluminum foil

Synthesis of Nanoparticles and Surface Modifications

Supporting Information

CHAPTER 3. FABRICATION TECHNOLOGIES OF CdSe/ZnS / Au NANOPARTICLES AND NANODEVICES. 3.1 THE SYNTHESIS OF Citrate-Capped Au NANOPARTICLES

A graphene oxide-based AIE biosensor with high selectivity toward bovine serum albumin

Supporting Information for. Highly durable Pd metal catalysts for the oxygen. reduction reaction in fuel cells; Coverage of Pd metal with.

Supporting Information

Supporting Information

were obtained from Timesnano, and chloroplatinic acid hydrate (H 2 PtCl 6, 37%-40%

Electronic Supplementary Information. L-cysteine induced hemin/g-quadruplex concatamers. electrocatalytic amplification with Pt-Pd supported on

A Novel Detection Technique of Hydrazine Hydrate: Modality Change of Hydrogen-Bonding Induced Rapid and Ultrasensitive Colorimetric Assay

Electronic supplementary information. A longwave optical ph sensor based on red upconversion

Urchin-like Ni-P microstructures: A facile synthesis, properties. and application in the fast removal of heavy-metal ions

Electronic Supplementary Information

Flexible Waterproof Rechargeable Hybrid Zinc Batteries Initiated. by Multifunctional Oxygen Vacancies-Rich Cobalt Oxide

Supporting Information

Nanoporous metals by dealloying multicomponent metallic glasses. Chen * Institute for Materials Research, Tohoku University, Sendai , Japan

Microscopy. Maggie L. Weber, Andrew J. Wilson, and Katherine A. Willets. Corresponding author:

Core-shell 2 mesoporous nanocarriers for metal-enhanced fluorescence

Stimulating Electrocatalytic Oxygen Reduction Activity on Nitrogen doped Graphene through Noncovalent Molecular Functionalisation

Supporting Information. High-Performance Supercapacitor

Supporting Information

Synthesis of Oxidized Graphene Anchored Porous. Manganese Sulfide Nanocrystal via the Nanoscale Kirkendall Effect. for supercapacitor

An extraordinarily stable catalyst: Pt NPs supported on two-dimensional Ti 3 C 2 X 2 (X=OH, F) nanosheets for Oxygen Reduction Reaction

Supplementary Material (ESI) for Chemical Communications This journal is (c) The Royal Society of Chemistry Supporting Information

Supporting Information

Supporting information

Sacrifical Template-Free Strategy

Specifically colorimetric recognition of calcium, strontium, barium. ions using 2-mercaptosuccinic acid-functionalized gold nanoparticles

Supporting Information

Transcription:

Amplified electrochemiluminescent immunosensing using apoferritin-templated poly(ethylenimine) nanoparticles as co-reactant Ni Liao, Ying Zhuo, Yaqin Chai, Yun Xiang, Yaling Cao, Ruo Yuan, Jing Han Education Ministry Key Laboratory on Luminescence and Real-Time Analysis, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, PR China. (Supplementary Material) EXPERIMENTAL SECTION Reagents and Materials. Apoferritin, Ru(bpy) 3 Cl 2 6H 2 O, Nafion (5 wt%), Gold chloride (HAuCl 4 ), sodium citrate and BSA (96 99%) were purchased from Sigma-Aldrich Co. (St. Louis, MO, USA). N-hydroxy succinimide (NHS) and N-(3-dimethylaminopropyl)-N -ethylcarbodiimidehydrochloride (EDC) were received from Shanghai Medpep Co. Ltd. (Shanghai, China). Poly (ethylenimine) (PEI, 50%) was purchased from Fluka (Switzerland). HCG and goat-anti-hcg were obtained from Biocell Company (Zhengzhou, China). PTCA was gotten from Lian Gang Dyestuff Chemical Industry Co. Ltd. (Liaoning, China). Nafion was diluted to 1 wt% with ethanol solution. Au nanoparticles with mean size of 16 nm were produced by reducing gold chloride tetrahydrate with citric acid at 100 C for half an hour. Phosphate buffer solutions (PBS) with various ph values and concentrations were prepared by mixing standard stock solutions of 0.1 M K 2 HPO 4, 0.1 M NaH 2 PO 4, 0.1 M KCl and adjusting the ph with 0.1 M H 3 PO 4 or NaOH, then diluting with doubly distilled water. All chemicals were analytical grade and used without further purification. All solutions were prepared with doubly distilled water and stored in the refrigerator (4 ºC). 1

Apparatus. The ECL emission was monitored by a model MPI-A electrochemiluminescence analyzer (Xi An Remax Electronic Science & Technology Co. Ltd., Xi An, China). The voltage of the photomultiplier tube (PMT) was set at 800V and scan rate was 100 mvs 1 in ECL detection. A conventional three-electrode system was used with Ag/AgCl (saturated KCl) as the reference electrode, a platinum wire as auxiliary electrode and a modified glass carbon electrode (GCE, Φ= 4 mm) as the working electrode in the experiment. Cyclic voltammetric (CV) measurements were carried out with a CHI 610A electrochemistry workstation (Shanghai CH Instruments, China). A three-electrode electrochemical cell was composed of a modified glass carbon electrode (GCE, Φ= 4 mm) as the working electrode, a platinum wire as the auxiliary electrode, and a saturated calomel electrode (SCE) as the reference electrode. The morphologies of different nanocomposites were characterized by scanning electronmicroscopy (SEM, S-4800, Hitachi, Tokyo, Japan) at an acceleration voltage of 20 kv. Preparation of PEI-templated apoferritin nanoparticles (Apo-PEI): Firstly, 50 µl apoferritin solution (48 mg/ml) was dispersed in 1 ml 0.1 M PBS (ph 7.4) and gradually adjusted to ph 2.0 with HCl solution (0.1 M) under continuously stirring for 20 min to make the apoferritin disassociate into its subunits. Then 50 µl 0.1 M PEI solution was added into apoferritin solution (ph 2.0) drop by drop with stirring to allow the PEI to diffuse around the subunits of the apoferritin. Subsequently, the ph was adjusted to 8.5 with 0.1 M NaOH added dropwise. The mixture was under continuously stirring for 2 h to allow the PEI to form a PEI core inside the apoferritin. The obtained 2

target was centrifugally washed extensively with doubly distilled water for three times to remove the surplus PEI. And then it was dispersed in 1 ml 0.1 M PBS (ph 7.4). Preparation of the biotin-modified apoferritin-templated PEI nanoparticles (bio-apo-pei): Briefly, EDC and NHS were used as coupling agents which catalyze the formation of amide bond between the carboxyl of biotin and the amino of apoferritin. 40 µl 0.5 mg/ml biotin was dissolved in 1 ml doubly distilled water under continual stirring. And then 0.5 ml EDC and NHS (4:1) mixture solution was added to the above solution and stirred for overnight to activate the carboxyl of biotin. Subsequently, 500 µl Apo-PEI was added and the reaction was allowed to stir for overnight at room temperature to produce bio-apo-pei. The resulting conjugates were washed for several times to remove free biotin, redispersed in 1 ml 0.1 M PBS (ph 7.4) and stored at 4 C. Preparation of bio-apo-pei/sa/ab2/cnts (Ab2 bioconjugates): To obtain more active -COOH groups of CNTs, 2.0 mg CNTs and 0.5 mg PTCA were dissolved in 5.0 ml doubly distilled water by continuous ultrasonication and then stirred at room temperature for overnight to decorate the surface of CNTs with PTCA via π-π stacking. And then, 2.5 ml EDC and NHS (4:1) mixture solution was added to the above solution and the resulting mixture was kept vigorous agitation for overnight at room temperature. Next, 100 µl 100 miu/ml anti-hcg solution and 15 µl 1 mg/ml streptavidin (SA) were added simultaneously and stirred at 4 C for 8 h, followed by centrifuged at 10000 rpm for 15 min and dispersed in 2 ml 0.1 M PBS (ph 7.4). Finally, 1 ml bio-apo-pei was added to the above solution and stirred continuously 3

for 4 h to obtain bio-apo-pei/sa/ab2/cnts (Ab2 bioconjugates). Fabrication of the electrochemiluminescence immunosensor: To obtain a mirror like surface, the glass carbon electrode (GCE, Φ= 4 mm) was polished with 0.3 and 0.05 µm alumina respectively. Then it was cleaned chemically by immersing it into freshly prepared 2:1 mixture of H 2 SO 4 and H 2 O 2 for 30 s. After a short rinse and followed by successive sonication in doubly distilled water and ethanol, the GCE was allowed to dry at room temperature. Subsequently, 1 mg GR and 1 mg CNTs was dissolved in 1mL 1 % Nf solution by ultrasonic dispersion. Then 5 µl GR-CNTs-Nf composite was coated onto a pretreated GCE surface and dried in the air. Then the GR-CNTs-Nf modified GCE was soaked in 10 mm Ru(bpy) 2+ 3 for 30 min and then immersed in nano-au solution for 2 h at 25 C. Subsequently, 15 µl anti-hcg (abbreviated as Ab1) was attached by incubating at 4 C for 12 h. The immunosensor was then washed with doubly distilled water to remove the physical adsorbed Ab1 and then incubated for 1 h with 15 µl of 1 % BSA, followed by washing with doubly distilled water. Ultimately, the obtained immunosensor was stored at 4 C when not in use. Experimental measurements: The measurement was based on a sandwich immunoassay method. Before measurement, the immunosensor was incubated in HCG solution with various concentrations at 37 C for 40 minutes. Next, the modified electrode was incubated in Ab2 bioconjugates for 40 minutes at 37 C. 5 µl 0.1 M PBS (ph 2.0) was added to the immunosensor surface at room temperature for 2 h to release the PEI. Finally, the resultant immunosensor was investigated with a MPI-A 4

electrochemiluminescence analyzer in 3 ml 0.1 M PBS (ph 7.4) at room temperature. Electrochemical behaviors of the electrochemiluminescence immunosensor: To gain a better understanding of the fabrication process of the electrochemiluminescence immunosensor, we also performed the cyclic voltammograms (CVs) experiments at different modified electrodes in 0.1M PBS solution (ph 7.4). No obvious redox peaks were observed at bare GCE (FigureS1, curve a) and GR-CNTs-Nf coated GCE (FigureS1, curve b) due to the lack of redox active molecule. Then Ru(bpy) 2+ 3 was coated on the modified electrode surface, the resulting electrode exhibited a stable and well-defined redox peaks between 1.02 and 1.15 V (FigureS1, curve c), indicating the good electrochemical redox activity of Ru(bpy) 2+ 3. The redox peak currents increased significantly when nano-au was assembled by electronic adsorption, since the excellent conductivity of nano-au could promote the electron transfer (FigureS1, curve d). When the electrode was modified with anti-hcg, the peak currents were decreased (FigureS1, curve e). Subsequently, the redox peak currents further decreased after the modified electrode was blocked with 0.25% BSA solution (FigureS1, curve f). Finally, when HCG antigen molecules were coupled covalently onto the antibody molecules, the redox peak currents decreased apparently (FigureS1, curve g). The reason for this was that the BSA and HCG protein layers on the electrode would retards the electron transfer. 5

FigureS1. Cyclic voltammograms performed in 0.1 M PBS (ph 7.4, 3 ml) (a) bare GCE; (b) GR-CNTs-Nf; (c) Ru(bpy) 2+ 3 /GR-CNTs-Nf; (d) nano-au/ru(bpy) 2+ 3 /GR-CNTs-Nf; (e) anti-hcg/nano-au/ru(bpy) 2+ 3 /GR-CNTs-Nf; (f) BSA/anti-HCG/nano-Au/Ru(bpy) 2+ 3 /GR-CNTs-Nf modified GCE; (g) the proposed immunosensor after reacted with 100 miu/ml HCG. The scan was from 0.8 to 1.3V with the rate of 100 mv/s and all potentials are given versus SCE. Application: The feasibility of the immunoassay for clinical applications was investigated by analyzing several real samples in comparison with the ELISA method. Five clinical serum samples were from the Ninth People s Hospital of Chongqing, China, were used. Serum samples were diluted to different concentrations with a PBS solution of ph 7.0. The results are shown in Table 1 and the recovery was in the range of 96.0%-104.0%, which confirmed that the proposed immunosensor could be reasonably applied in the clinical determination of HCG. 6

Table1 Experimental results of different methods obtained in serum samples. Sample number Added (miu/ml) Found (miu/ml) a Recovery (%) 1 0.01 0.0104 ± 0.006 104.0 2 0.10 0.096 ± 0.02 96.0 3 1.00 0.98 ± 0.03 98.0 4 10.00 10.24 ± 0.01 102.4 5 20.00 20.36 ± 0.14 101.8 a Mean value ± SD of three measurements. 7