(HSI) LIMITED WARRANTY

Similar documents
GMVC8. ComfortNet -Compatible. Heating Input: 70, ,000 BTU/h. Two-Stage, Variable-Speed Gas Furnace

GB5BM Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler WARRANTY

REPAIR PARTS. GDH8 80% Two-Stage Hybrid Dedicated Downflow Gas Furnace

PRODUCT SPECIFICATIONS

REPAIR PARTS. GDS8 80% Furnace GDS80453AXCA GDS80453AXCB GDS80703AXCA GDS80703AXCB GDS80904BXCA GDS80904BXCB GDS81155CXCA GDS81155CXCB

CHAMPION MARQUIS SPECIFICATIONS GUIDE UIDE FOR COMMERCIAL MODELS

B6VMAX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Industrial/Commercial Evaporative Coolers Specification Guide

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

GMVM96 / GCVM96 ComfortNet -Compatible, Multi-Position, Modulating Variable-Speed Gas Furnace

REPAIR PARTS. GMS95 Single Stage Upflow Furnace GMS950453BXAB GMS950703BXAB GMS950704CXAB GMS950904CXAB GMS951155DXAB.

REPAIR PARTS. GDS8 80% Furnace

PARTS MANUAL Gas Furnace F8MXN, F8MXL, G8MXN, G8MXL

REPAIR PARTS. GME8 80% Upflow Furnace

REPAIR PARTS. AMH95 Amana brand 95% Hybrid Furnace AMH950453BXAA AMH950703BXAA AMH950704CXAA AMH950904CXAA AMH950905DXAA AMH951155DXAA

GMVC 80% Variable Speed Communicating Furnace

REPAIR PARTS. GMS9*XA Gas Furnace

Service Parts. AMV9*XA Upflow/Horizontal/Two- Stage/Variable Speed 90% AFUE Gas Furnace. Models and manufacturing numbers in this manual

REPAIR PARTS. GMVC8 80% Variable Speed Communicating Furnace

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

10-year industry best core warranty. 2-year warranty on balance of unit.

REPAIR PARTS. GMEC 96% ECM Up Flow Furnace

Two-Stage, Variable-Speed Gas Furnace

REPAIR PARTS. GMV9* Variable Speed Furnace

REPAIR PARTS. A/GPG13 Package Gas Units

REPAIR PARTS. GPH13 "M" Series Horizontal Package Heat Pumps GPH1324M41AA GPH1330M41AA GPH1336M41AA GPH1342M41AA GPH1348M41AA GPH1360M41AA

AMVC 80% Variable Speed Communicating Furnace

Product Data. CAPVU Evaporator Coil A Coil --- Uncased Upflow, Downflow CAPVU

REPAIR PARTS. GUP, GUPI, and GUPX "B" SERIES

nufacturing Company, L.P San Felipe, Suite

Y1SA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Goodman Manufacturing Company, L.P San Felipe, Suite 500 Houston, TX 77056

Model 33SZ Basic Unit OPTIONAL FILTER RH COIL CONNECTION PRIMARY/ DEDICATED OUTDOOR AIR MULTI-POINT FLOW SENSOR 5 3/4" (146)

REPAIR PARTS. GMEC 96% EEM Up Flow Furnace. This manual is to be used by qualified technicians only.

REPAIR PARTS. *MVC95 Variable Speed Furnace

REPAIR PARTS. *CVC95 C'Flow Variable Speed Furnace ACVC950714CXBA ACVC950915DXBA GCVC950714CXBA GCVC950915DXBA

END4X, ENW4X, ENA4X. Product Specifications VERTICAL EVAPORATOR COILS ALL N COIL MODELS CASED N COILS UNCASED N COILS ENA4X WARRANTY*

BV SERIES. VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton

PARTS MANUAL Gas Furnace F9MAC, G9MAC

Product Data. CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil N Coil Cased and Uncased Upflow, Downflow

GMV95/GCV9 MULTI-POSITION, TWO-STAGE/VARIABLE-SPEED GAS FURNACE

REPAIR PARTS. GPC13 "M" Series 3-5 Ton Package Coolers

REPAIR PARTS. *MVM96 Variable Speed Furnace

REPAIR PARTS. GPH14 H-SERIES R-410A Package Heat Pumps GPH1424H41AA GPH1430H41AA GPH1436H41AA GPH1442H41AA GPH1448H41AA GPH1460H41AA

579(XX).(X)(X)(X)(X) Modularized Roof Top Air Conditioner

DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE

REPAIR PARTS. GPH13 "H" Model Package Heat Pumps GPH1324H41AB GPH1330H41AB GPH1336H41AB GPH1342H41AB GPH1348H41BB GPH1360H41BB

4HP13 PRODUCT SPECIFICATIONS 13 SEER SPLIT SYSTEM HEAT PUMP WARRANTY

REPAIR PARTS. GMSS 96% PSC Up Flow Furnace. This manual is to be used by qualified technicians only.

REPAIR PARTS. *CVC9 90% C'Flow 2-Stage Variable Speed Furnace

Product Data CNPVP, CNPVT, CNPVU, CNRVU EVAPORATOR COIL N COIL - CASED AND UNCASED UPFLOW, DOWNFLOW

REPAIR PARTS. GCH95 95% Counterflow Hybrid Furnace. This manual is to be used by qualified technicians only. This manual replaces RP-597C.

P a g e 5 1 of R e p o r t P B 4 / 0 9

EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

REPAIR PARTS. [A/G]PG15 Package Gas-Electric Units

REPAIR PARTS. DP13CH Residential Package Heat Pump

REPAIR PARTS. GKS9 Single Stage PSC Upflow Furnace. This manual is to be used by qualified technicians only. This manual replaces RP-606B.

P a g e 3 6 of R e p o r t P B 4 / 0 9

McQuay. Water Source Heat Pump. VF, VG, VP Vintage E, F, G. Last Manufactured: Replacement Parts List No Revision B 02/2017

Singer. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012

ENVIRONMENTALLY SOUND R 410A REFRIGERANT

SRP RESIDENTIAL GARAGE HEATERS

REPAIR PARTS 14 SEER DUEL FUEL PACKAGE MODELS

REPAIR PARTS. GMH95 95% Upflow Hybrid Furnace

REPAIR PARTS. ARUF Aluminum Coil Air Handler

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1

TECHNICAL INFORMATION MANUAL

42C/V. Fan Coil Unit 42C/V

CAUTION. All safety information must be followed as provided in this Technical Sheet and in Service Manual RS

REPAIR PARTS. GMVC 96% ECM Up Flow Furnace. This manual is to be used by qualified technicians only.

REPAIR PARTS. AMH95 Amana Brand 95% Hybrid Furnace

ENH4X. Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS WARRANTY*

REPAIR PARTS. ARUF Air Handlers ARUF18B14AA ARUF24B14AA ARUF30B14AA ARUF36C14AA ARUF42C14AA ARUF48D14AA ARUF60D14AA

T h e C S E T I P r o j e c t

General Purpose Relays Types K, R, N, and C

THIS MANUAL IS THE PROPERTY OF THE OWNER. PLEASE BE SURE TO LEAVE IT WITH THE OWNER WHEN YOU LEAVE THE JOB.

REPAIR PARTS. *PD14 Dual Fuel Package Units

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL

REPAIR PARTS. AVPTC Air Handler. This manual is to be used by qualified technicians only. This manual replaces RP-775E.

Emerson Climate Technologies (India) Private Limited Karad Dhebewadi Road Karad INDIA

Chimney Sizing. Project Name: Location: Type Appliance: Hot Water Heater Incinerator. LP Gas #2 Oil #6 Oil Wood/Coal Waste (Type ) Appliance Input:

REPAIR PARTS. GPG14 "M" Series Residential Package Gas Units. This manual is to be used by qualified technicians only. This manual replaces RP-G3001.

Energy Efficient Easy to Install Extended Service Life. Horizontal Direct Drive Blower Coils BUILD YOUR REPUTATION ON OURS

Vacuum capacitors overview Capacitor selection guides

REPAIR PARTS. GPH H-SERIES Package Heat Pumps

Addendum to ARI Standard , Air Terminals September 2002

nufacturing Company, L.P San Felipe, Suite 500

Sound Rating of Ducted Air Moving and Conditioning Equipment

FAN ENGINEERING. Field Testing of Fans. Twin City Fan FE-900. Introduction. Testing Equipment. Testing Standards. Prior to Testing

Table of Contents. Oil Furnace, Low Profile Highboy, OH6 Series 6. Oil Furnace, Low Profile Highboy, OH8 Series 7. Oil Furnace, Lowboy, OL5 Series 8

2225C/P (.220 x.250 )

6 5 /10 0 /13 0 W a t t s E C S S e r ie s A C D C. S p e c if ic a t io n. G e n e r a l. In p u t. E n v ir o n m e n t a l.

SILVER CAST IRON BOILERS. Pennco SILVER makes Simple Comfort, Affordable.

PANDUCT Type E Slotted Wall Wiring Duct

NME1854 & FME2404 SERVICE PARTS

R- 410A R-22 Size (tons) Shipping Weight (lbs) WLAU184AA 1-1/ WLAU182AA 1-1/ WLAU244AA. Model /2

Panel Mount, Single Phase 120 and 240 Volt Fixed Shaft (click blue text for more details)

CUSTOM MODULES (Commercial / Moisture Resistant / Hermetic)

Manual Control. Class 11-3RV, SMF, MMS. Wiring Diagrams 8/130. Signaling Contact for Class 11-3RV. Typical Wiring Diagrams Class SMF.

Instruction Sheet COOL SERIES DUCT COOL LISTED H NK O. PR D C FE - Re ove r fro e c sed rea. I Page 1 Rev A

Transcription:

ama The Payne PG8MAA/JAA 80% AFUE Gas Furnaces feature 4-way multipoise design and through-the-furnace downflow venting. The PG8MAA/JAA furnaces are approved f use with natural propane gas, and the PG8JAA is approved f use in Low NOx Air Quality Management Districts. STANDARD FEATURES Four-position furnace: upflow, hizontal right, hizontal left, downflow Electronic control center Adjustable heating air temperature rise, LED diagnostics and self test feature Hot surface ignition (HSI) Model P G 8M/P G 8J S eries A MUL TIP OIS E G AS F UR NAC E LIMITED WARRANTY 20-year warranty on heat exchanger 1-year parts warranty on all other components S S -P G 8M-01

A02021 NOT E S : 1. T wo additional 7 /8 -in. dia knockouts are located in the top plate. 2. Minimum return-air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer's recommendations f equivalent diameters. 3. Minimum return-air opening at furnace: a. F 800 C F M-16-in. round 14 1 / 2 x 12-in. rectangle. b. F 1200 C FM-20-in. round 14 1 / x 19 1 2 / 2 -in. rectangle. c. F 1600 C FM-22-in. round 14 1 / x 23 1 2 / 4 -in. rectangle. d. F airflow requirements above 1800 C F M, see Air Delivery table in P roduct Data literature f specific use of single side inlets. T he use of both side inlets, a combination of 1 side and the bottom, the bottom only will ensure adequate return air openings f airflow requirements above 1800 C FM. UNIT SIZE 024045 036045 024070 036070 048070 042090 048090 060090 036110 048110 066110 048135 A (CABINET WIDTH) D (SUPPLY WIDTH) DIME NS IONS (In.) E (BOTTOM RETURN WIDTH) 060135 24-1/2 22-7/8 23 15-1/16 4 (note 1) 060155 24-1/2 22-7/8 23 15-1/16 4 (note 1) 1) 135 and 155 size furnaces require five-inch vents. Use a 4-5 inch vent adapter between furnace and vent stack. 2) See Installation Instructions f complete installation requirements. F (TOP VENT OUTLET) VENT CONNECTION SIZE (see notes 1 & 2) 14-3/16 12-9/16 12-11/16 9-5/16 4 14-3/16 12-9/16 12-11/16 9-5/16 4 14-3/16 12-9/16 12-11/16 9-5/16 4 14-3/16 12-9/16 12-11/16 9-5/16 4 17-1/2 15-7/8 16-1/8 11-9/16 4 17-1/2 15-7/8 16-1/8 11-9/16 4 21 19-3/8 19-1/2 13-5/16 4 21 19-3/8 19-1/2 13-5/16 4 17-1/2 15-7/8 16-1/8 11-9/16 4 21 19-3/8 19-1/2 13-5/16 4 21 19-3/8 19-1/2 13-5/16 4 21 19-3/8 19-1/2 13-5/16 4 (note 1) SHIPPING WEIGHT 104 107 111 115 126 127 140 146 135 146 152 149 163 170-2-

ama C A NA DIA N GAS A S S OC IA T ION APPR OVED R ME E T S DOE R E S IDE NT IA L C ONS E R V A T ION S E R V IC E S P R OG R A M S T A NDA R DS. B efe purchas ing this appliance, read imptant energy cos t and efficiency infmation available from your retailer. -3-

S P E C IF IC A T IONS UNIT S IZE 024045 036045 024070 036070 042090 048090 R AT ING S A ND P E R F OR MA NC E Input B tuh* P G8JAA Upflow; all P G8MAA 44,000 44,000 66,000 66,000 88,000 88,000 Nonweatherized IC S PG8JAA Downflow/Hizontal 42,000 42,000 63,000 63,000 84,000 84,000 Output C apacity (B tuh) P G8JAA Upflow; all P G8MAA 35,000 36,000 53,000 54,000 71,000 71,000 Nonweatherized IC S PG8JAA Downflow/Hizontal 34,000 34,000 51,000 51,000 68,000 68,000 AF UE 80.0 80.0 80.0 80.0 80.0 80.0 C ertified T emperature R ise R ange o F 30-60 20-50 40-70 30-60 40-70 30-60 C ertified E xternal S tatic P ressure Heat/C ool 0.10/0.50 0.10/0.50 0.12/0.50 0.12/0.50 0.15/0.50 0.15/0.50 Heating 920 1250 830 1195 1375 1505 Airflow C F M C ooling 845 1160 900 1200 1385 1720 E L E C T R IC A L Unit Volts-Hertz-P hase 115-60-1 Operating Voltage R ange Min-Max 104-127 Maximum Unit Amps 5.6 7.0 5.0 6.7 8.1 9.8 Maximum Wire Length (Measured 1 Way in Ft) 47 39 52 40 34 28 Minimum Wire S ize 14 Maximum F use C kt B kr S ize (Amps)** 15 Transfmer (24v) 40va E xternal C ontrol Heating 12va P ower Available C ooling 35va Air C onditioning Blower R elay S tandard C ONT R OL S Limit C ontrol S P S T Heating Blower C ontrol S olid-s tate Time Operation Burners (Monopt) 2 2 3 3 4 4 G as C onnection S ize 1/2-in. NP T G A S C ONT R OL S White R odgers G as V alve (R edundant) Min Inlet P ressure (In. wc) 4.5 (Natural G as) Max Inlet P ressure (In. wc) 13.6 (Natural G as) Ignition Device Hot S urface B L OWE R DATA Direct-Drive Mot HP (P S C ) 1/5 1/3 1/5 1/3 1/3 1/2 Mot Full Load Amps 2.9 5.2 2.9 5.2 5.2 7.9 R P M (Nominal)-S peeds 1075-3 1075-3 1075-3 1075-3 1075-3 1075-3 B lower Wheel Diameter x Width (In.) 10 x 6 10 x 6 10 x 6 10 x 6 10 x 8 10 x 10 F ILT E R AR R ANG E ME NT E xternal filter rack required * G as input ratings are certified f elevations to 2000 ft. F elevations above 2000 ft, reduce ratings 4 percent f each 1000 ft above sea level. R efer to National F uel G as C ode T able F 4 furnace Installation Instructions. In C anada, derate the unit 10 percent f elevations 2000 ft to 4500 ft above sea level. ** Time-delay type is recommended. C apacity in accdance with U.S. G overnment DOE test procedures. Airflow shown is f bottom only return-air supply. F air delivery above 1800 C F M, see Air Delivery table f other options. A filter is required f each returnair supply. An airflow reduction of up to 7% may occur when using the facty-specified 4-5/16-inch wide, high efficiency media filter. IC S -Isolated C ombustion S ystem N/A-Not Applicable -4-

S P E C IF IC A T IONS UNIT S IZE 036110 048110 066110 048135 066135 060155 R AT ING S A ND P E R F OR MA NC E Input B tuh* P G8JAA Upflow; all P G8MAA 110,000 110,000 110,000 132,000 132,000 154,000 Nonweatherized IC S PG8JAA Downflow/Hizontal 105,000 105,000 105,000 126,000 126,000 147,000 Output C apacity (B tuh) P G8JAA Upflow; all P G8MAA 89,000 89,000 89,000 107,000 107,000 125,000 Nonweatherized IC S PG8JAA Downflow/Hizontal 85,000 85,000 85,000 102,000 107,000 119,000 AF UE 80.0 80.0 80.0 80.0 80.0 80.0 C ertified T emperature R ise R ange o F 50-80 40-70 30-60 50-80 40-70 40-75 C ertified E xternal S tatic P ressure Heat/C ool 0.20/0.50 0.20/0.50 0.20/0.80 0.20/0.50 0.20/0.50 0.20/0.50 Heating 1335 1515 1900 1525 1850 1790 Airflow C F M C ooling 1335 1680 2220 1710 2110 2230 E L E C T R IC A L Unit Volts-Hertz-P hase 115-60-1 Operating Voltage R ange Min-Max 104-127 Maximum Unit Amps 8.2 10.1 13.7 10.1 14.4 15.0 Maximum Wire Length (Measured 1 Way in Ft) 34 28 32 28 30 29 Minimum Wire S ize 14 12 14 12 Maximum F use C kt B kr S ize (Amps)** 15 20 15 20 Transfmer (24v) 40va E xternal C ontrol Heating 12va P ower Available C ooling 35va Air C onditioning Blower R elay S tandard C ONT R OL S Limit C ontrol S P S T Heating Blower C ontrol S olid-s tate Time Operation Burners (Monopt) 5 5 5 6 6 7 G as C onnection S ize 1/2-in. NP T G A S C ONT R OL S White R odgers G as V alve (R edundant) Min Inlet P ressure (In. wc) 4.5 (Natural G as) Max Inlet P ressure (In. wc) 13.6 (Natural G as) Ignition Device Hot S urface B L OWE R DATA Direct-Drive Mot HP (P S C ) 1/3 1/2 3/4 1/2 3/4 3/4 Mot Full Load Amps 5.2 7.9 11.1 7.9 11.1 11.1 R P M (Nominal)-S peeds 1075-3 1075-3 1075-3 1075-3 1075-3 1075-3 B lower Wheel Diameter x Width (In.) 10 x 8 10 x 10 11 x 11 10 x10 11 x 11 11 x 11 F ILT E R AR R ANG E ME NT E xternal filter rack required * G as input ratings are certified f elevations to 2000 ft. F elevations above 2000 ft, reduce ratings 4 percent f each 1000 ft above sea level. R efer to National F uel G as C ode T able F 4 furnace Installation Instructions. In C anada, derate the unit 10 percent f elevations 2000 ft to 4500 ft above sea level. ** Time-delay type is recommended. C apacity in accdance with U.S. G overnment DOE test procedures. Airflow shown is f bottom only return-air supply. F air delivery above 1800 C F M, see Air Delivery table f other options. A filter is required f each returnair supply. An airflow reduction of up to 7% may occur when using the facty-specified 4-5/16-inch wide, high efficiency media filter. IC S -Isolated C ombustion S ystem N/A-Not Applicable -5-

F A C T OR Y -A UT HOR IZE D DE A L E R -INS T A L L E D A C C E S S OR IE S DESCRIPTION PART NO. 024045 036045 024070 036070 048070 042090 048090 060090 036110 048110 066110 048135 066135 060155 Exteri Filter Rack - universal, one inch (adjustable from 14" to 24") with filter Unframed filter, one inch - 16x25 Unframed filter, one inch - 20x25 Unframed filter, one inch - 24x25 KGAFR0301ALL KGAFR0306ALL (6-pack) KGAWF1301UFR KGAWF1306UFR (6-pack) KGAWF1401UFR KGAWF1406UFR (6 pack) KGAWF1501UFR KGAWF1506UFR (6 pack) x x x x x x x s s x s s s s s x x x x x Twinning Kit KGATW0601HSI x x x x x x x x x x x x x x Combustible Flo Base (not required when evapat coil case is used) Downflow Vent Guard (not required when vent is routed through cabinet) Vent Extension Kit (may be used when vent is routed through cabinet in downflow) Chimney Adapter Kit - 4 i nch vent Chimney Adapter Kit - 5 i nch vent Natural-to-Propane Gas Conversion Kit (Single Kit) * Propane-to-Natural Gas Conversion Kit (Single Kit) Gas Orifice Kit (Qty 50) Size 42 Gas Orifice Kit (Qty 50) Size 43 Gas Orifice Kit (Qty 50) Size 44 Gas Orifice Kit (Qty 50) Size 45 Gas Orifice Kit (Qty 50) Size 46 Gas Orifice Kit (Qty 50) Size 47 Gas Orifice Kit (Qty 50) Size 48 Gas Orifice Kit (Qty 50) Size 54 Gas Orifice Kit (Qty 50) Size 55 Gas Orifice Kit (Qty 50) Size 56 Gas Orifice Kit (Qty 50) 1.25 mm Gas Orifice Kit (Qty 50) 1.30 mm KGASB0201ALL x x x x x x x x x x x x x x KGAVG0101DFG x x x x x x x x x x x x x x KGAVE0101DNH x x x x x x x x x x x x x x KGACA02014FC x x x x x x x x x x x KGACA02015FC x x x KGANP2901ALL x x x x x x x x x x x x x x KGAPN2301ALL x x x x x x x x x x x x x x KGAHA0150N42 KGAHA0250N43 KGAHA0350N44 KGAHA0450N45 KGAHA0550N46 KGAHA1550N47 KGAHA1650N48 KGAHA0650P54 KGAHA0750P55 KGAHA0850P56 KGAHA5750125 KGAHA5750130 * Facty-authized and field installed. Gas conversion kits are A.G.A./C.G.A. recognized. s 16x25 filters suitable f side return on all furnace sizes. x x x x x x x x x x x x x See Installation Instructions f model, altitude, and heat value usages. x x -6-

UNIT SIZE 024045 036045 024070 036070 042090 048090 036110 048110 066110 RETURN-AIR SUPPLY Only Both Sides 1 Side & 1 Side Only SPEED 048135 066135 060155 Only Both Sides 1 Side & 1 Side Only Only Both Sides 1 Side & AIR DELIVERY-CFM (With Filters)* EXTERNAL STATIC PRESSURE (In. wc) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1085 1035 975 915 845 770 675 565 920 875 830 770 710 640 555 440 820 775 730 680 620 555 470 360 1440 1360 1250 1030 835 725 1425 1320 1200 1650 1515 1385 2060 1790 1505 1625 1510 1360 2035 1745 1530 2530 2230 1920 1375 1300 1210 1010 815 700 1375 1280 1175 1600 1485 1360 1985 1765 1505 1575 1470 1335 1965 1710 1515 2470 2205 1900 1305 1240 1160 980 790 675 1320 1240 1145 1535 1440 1320 1915 1715 1480 1515 1415 1295 1880 1650 1470 2400 2165 1880 1240 1175 1100 945 760 645 1265 1205 1105 1465 1380 1260 1820 1645 1440 1445 1355 1250 1790 1560 1400 2320 2110 1845 1160 1115 1040 900 720 600 1200 1140 1050 1385 1300 1195 1720 1560 1375 1355 1285 1180 1680 1450 1310 2220 2035 1795 1070 1040 965 845 675 555 1125 1075 990 1285 1220 1120 1610 1470 1300 1260 1185 1100 1495 1340 1215 2115 1950 1730 975 950 885 775 610 475 1035 995 920 1175 1115 1025 1490 1345 1190 1165 1070 985 1365 1205 1095 2000 1855 1650 870 850 790 680 490 390 940 905 840 1055 990 915 1340 1195 1045 990 890 810 1215 1090 990 1865 1740 1555 0.9 1.0 390 195 250 190 2540 2495 2430 2355 2265 2175 2065 1935 1785 1650 2125 2120 2105 2060 2010 1940 1840 1730 1615 1485 1790 1795 1790 1765 1720 1650 1585 1500 1390 1280 2090 1790 1545 2485 2195 1880 730 725 670 490 375 300 830 790 725 895 830 710 1135 1010 890 785 725 1075 955 830 1730 1615 1460 560 575 520 335 265 655 620 555 645 600 565 925 820 740 875 750 670 1590 1485 1340 2010 1755 1525 2400 2150 1850 1930 1705 1500 2310 2090 1820 * A filter is required f each return-air supply. Airflow perfmance includes 1" washable filter media such as contained in facty-authized accessy filter rack. To determine airflow perfmance without this filter, assume an additional.1 available external static pressure. -Indicates unstable operating conditions. 1835 1640 1450 2215 2000 1780 1710 1550 1380 2110 1920 1715 2320 2250 2155 2055 1970 1855 1725 1600 1450 1280 2125 2065 1995 1910 1815 1710 1610 1490 1340 1175 1845 1825 1765 1710 1650 1570 1475 1370 1240 1100 1 Side Only 2465 2115 1800 2430 2105 1790 2375 2075 1770 2305 2030 1735 2230 1980 1695 1590 1465 1315 2000 1825 1635 2110 1910 1640 1470 1360 1215 1880 1720 1540 2000 1830 1570 1335 1210 1005 1725 1565 1415 1865 1725 1465 1025 945 855 1535 1405 1290 1725 1590 1345 835 785 670 1355 1255 1160 1545 1425 1225-7-

S PE CIFICATIONS S UBJE CT TO CHANGE WITHOUT NOTICE UNIT MUS T B E INS T ALLE D IN AC C OR DANC E WITH INS TALLATION INS TR UCTIONS Cancels: NE W 2002 Payne Heating & Cooling P.O. Box 70, Indianapolis, IN 46206 Catalog No. 52PG-8M0 PR INTE D IN U.S.A. 8-02 -8-