Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

Similar documents
The. Family of Mercury Analyzers. Hydra II AA Atomic Absorption Detection Liquid Samples

110 Lowell Rd Hudson, NH USA Tel:

Product Descriptions and Offerings

Hydra-C Application Note: 1076

Basic Digestion Principles

DMA-80L TECHNICAL SPECIFICATIONS

Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Mercury Stack Monitor SM-4

PRINCIPLE OF ICP- AES

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

Elemental analysis of river sediment using the Agilent 4200 MP-AES

Member of the envea Group. Automatic Mercury Analyzer for the Laboratory

cobas e 411 analyzer Confidence in every result.

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

Determination of the Halogen Elements in the Deep UV Region of the Spectrum by ICP - OES

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

U.S. EPA SW-846 Method 6010C using the Prodigy High Dispersion ICP

novaa 800 D Atomic Absorption Spectrometer

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

Quality Control Procedures for Graphite Furnace AAS using Avanta Software

Shorten your Time-to-Result

TOXICOLOGY & FORENSIC APPLICATIONS

Atomic Absorption Spectrometer ZEEnit P series

Agilent G2350A Atomic Emission Detector (AED)

OXEA - Online Elemental Analyzer

S2 PICOFOX. Innovation with Integrity. Spectrometry Solutions TXRF

SIMPLICITY AND TECHNOLOGY THE LIASYS CLINICAL CHEMISTRY SYSTEMS FOR PHYSICIAN OFFICE LABORATORIES

Fusion UV/Persulfate TOC Analyzer

Meeting the Challenges of Soil Analysis with the Avio 200 ICP-OES

The Clinical Chemistry System that offers more so you do less!

Carbon (Organic, and Inorganic)

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

CHEMISTRY WORKSTATION. The power of proven quality GIVING YOU PEACE OF MIND

A new chapter. medicacorp.com

S2 PICOFOX. Innovation with Integrity. Benchtop TXRF Spectrometer TXRF

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

Analysis of domestic sludge using the Agilent 4200 MP-AES

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

Accurate and Precise Sulfur Analysis using the Thermo Scientific FlashSmart Elemental Analyzer

SKALAR. your partner in chemistry automation. Primacs SN Protein-Nitrogen Analyzer

CLINICAL CHEMISTRY ANALYSER. The economical solution for all your needs GIVING YOU PEACE OF MIND

costech instruments ECS 4010 Elemental Combustion System CHNS-O

JAPAN QUALITY. Automated Clinical Analyzer

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

SKALAR. your partner in chemistry automation. Primacs SNC Total Carbon and Total Nitrogen Analyzer

Fusion UV/Persulfate TOC Analyzer

TRL-TOC-M MODEL MODULAR TC/IC/TOC/TN ANALYZER FOR LIQUID AND SOLID SAMPLES. TRL-TOC-M Model TC/IC/TOC/TN Analyzers are designed to handle:

AULA 254 AULA Fluorescence

Rapid Catalyst Screening Reactors

473-SHX Dew Point Mirror

cobas 6000 analyzer series Flexibility you can build on

Certificate of Analysis

JAPAN QUALITY. Automated Clinical Analyzer

AutoChem II 2920 A Catalyst Characterization Laboratory

Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:

Varian SpectrAA 220/880 Zeeman

Elemental analysis by X-ray f luorescence. High performance EDXRF elemental analyzer

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Total Organic Carbon, Total Nitrogen

FoodScreen Radiological Food Screening System

USGS Troy WSC Laboratory Inductively Coupled Plasma- NH4Cl Soil Extracts SOP 425 Jordan Road Rev. No. 2.0 Troy, NY Date: 03/16/2012 Page 1 of 7

The challenges of field sensors for trace metal detection. Chris Searle Product Manager Trace2o Ltd

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

GTEK Laboratory Atomic Absorption Spectrometer AAS6000 Brochure

Compact Titration Compact Titrator G20. One Click Titration Simple & Dependable

Speed and flexibility

ASTORIA PACIFIC. Automated Wet-Chemistry Analyzers and Diagnostic Reagents. rapid-t

OPTIMIZING METALS SAMPLE PREP

Advanced technics in the. (TIC/TOC/TNb)

2Fe 2 O 3 +3H 2 S FeS+FeS x +S+3H 2 O

ALPHA. Innovation with Integrity. The very compact and smart FTIR spectrometer FTIR

SKALAR. your partner in chemistry automation. Formacs series Total Organic Carbon & Total Nitrogen Analyzers

473 Dew Point Hygrometer

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

Atomic Absorption Spectroscopy

The first address for Titration. TITRONIC 300 and TitroLine 5000

PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009]

Prof. Dr. Biljana Škrbić, Jelena Živančev

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

OXITEST Oxidation Test Reactor

The Evolution of Inductively Coupled Plasma - Optical Emission Spectroscopy (ICP-OES)

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

Not Just for Paint Chips Anymore. High Throughput, Open Vessel Microwave Digestion of Matrices Requiring Moderate Conditions

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

Combustion Ion Chromatography. Fast and reliable determination of halogens and sulfur

Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS

cobas 8000 modular analyzer series Intelligent LabPower

Appendix: Laboratory Testing Methods

2101 Atomic Spectroscopy

high performance OPTIC 3 and applications a total analytical solution

Overview Brochure Comprehensive range of instrumentation for the measurement of moisture and oxygen

H E L P I N G C H E M I S T S. UltraCLAVE. The Next Generation Microwave Digestion System

473 Dew Point Hygrometer

13. CARBON AND CARBONATE ANALYSES, LEG 9

University Wet Chemistry Analyzer Packages

Transcription:

Innovative 0.01 0.1 1 10 Intuitive Concentration (ppb) R = 0.99999 Versatile Hydra II C Mercury Analyzer

At Teledyne Leeman Labs; atomic spectroscopy is our business our only business. We are industry leading innovators with a proven track record providing systems that deliver outstanding performance, robustness and operational simplicity. Teledyne Leeman Labs mercury analyzers were the first to offer turnkey operation for Hg analysis. The Hydra II analyzers incorporate technological improvements to give you exceptional performance, greater analysis throughput and simplified operation. Furthermore, the Hydra II analyzers are built around an innovative, integrated modular design so that the system can be easily reconfigured to perform both Hg reduction or combustion techniques, as your analytical requirements change.

Key Features of the Hydra II C Maintenance of the catalyst and gold trap in minutes Pressure monitoring, to alert user of required maintenance Standard usable range 0.001 ng 1500 ng 0.001 ng instrument detection limit* Volatile Hydrocarbon (VHC) mode On-the-fly sample programming 70 position autosampler; virtual addition to extend beyond 70 samples *System Blank Detection Limit is determined by 10 no-boat readings under ideal system conditions. The standard deviation of the 10 readings is multiplied by 3 to determine final value.

The Hydra II C Direct Analysis of Solids, Semi-Solids and Liquids The Hydra II C is a fully automated analyzer that measures mercury in solid, semi-solid, and liquid sample matrices directly without any acid digestion (sample preparation). It employs the technique of sample combustion (thermal decomposition), mercury concentration via gold amalgamation and detection by cold vapor atomic absorption. The biggest advantage of the Hydra II C is that typically no sample preparation is required. And, because sample prep is generally not required; no hazardous waste is generated that would have to be disposed of safely and with high cost. Principle of Operation A weighed sample is deposited into a sample boat (1) and then introduced into the Hydra II C where oxygen begins to flow over the sample. The decomposition furnace temperature is then increased in two stages; first to dry the sample (2), then to decompose it. The evolved gases are carried through a heated catalyst (3) to produce free mercury while removing halogens, nitrogen oxides, and sulfur oxides. The remaining Eliminates Transcription Errors combustion products including elemental mercury (Hg 0 ) are swept through a drying tube (4) and a gold amalgamation trap (5) where elemental Hg is trapped and concentrated. After the amalgamation step, the trap is heated to release the mercury into a carrier gas which transports it into an atomic absorption spectrometer (6). Elegant yet Simple Design Weigh Sample Automatic Weight Transfer Building sample sequences can take considerable effort. The Hydra II C enables sample weights to be automatically transferred directly into the sample table saving time and eliminating transcription errors. At the heart of the system is the catalyst tube which can be easily replaced without tools in as little as a minute.

Applications Beverages Blood Coal Effluent Fertilizer Feed Fly Ash Foods Hair Minerals Ore Petrochemical Sediment Sludge Soil Urine Wastewater Water Sediment Coal Oyster Taste Dogfish Matrix Independent Calibration A key benefit of the thermal decomposition process is its ability to report accurate results regardless of differences in sample matrix. The table below shows the system accuracy for a diverse variety of sample types all obtained from a single aqueous calibration curve. Alternatively, certified reference materials may be used as standards to calibrate the system. Sample No. Certificate (µg/g) Measured (µg/g) Recovery % Bovine Liver 1577 0.016 0.0178 111.7 Blood Lypho 1 0.0096 0.0091 94.8 Dogfish Dorm-2 4.64 4.34 93.5 Oyster 1566 0.057 0.061 107.0 Soil 8406 0.06 0.061 101.7 Coal HC-35150 0.176 0.177 100.6 Innovative Integrated Modular Design The Hydra II modular design enables one system technique to be reconfigured to another in your lab should your analysis needs change saving money, time and bench space. Hydra II C Atomic Absorption Detection Direct analysis of Solid, Semi Solids and Liquid Samples Hydra II AA Atomic Absorption Detection Liquid Samples

Hydra II Envoy Software Instrument Control is fully automated and appears on a single screen. The graphical display helps operators to understand how the system functions. System parameters are automatically stored and can be recalled at any time to satisfy audit requirements. On start-up, simply clicking the start button returns all system conditions to the last setting saved with the method. On-the-fly Sample Programming saves valuable time by allowing the operator to start a sample sequence even if individual sample entries are not yet complete. Samples can be easily located, added and positioned using the convenient rack map display. Intelligent Quality Control enables the analyst to define acceptance limits for quality control checks and to choose from a variety of corrective actions when the limits are not met. Each QC sample can be programmed as an initial, recurring, and/or final QC with unique corrective actions. Preventive Maintenance. The software keeps a record of routine maintenance and notifies the analyst when maintenance is required. When a maintenance procedure is required, the Hydra II provides the analyst with step-by-step instructions, including audio/visual support.

Technical Specifications Minimum Computer Requirements Microsoft Windows 10 2 GB RAM for Microsoft Windows 10 Video running 1024 x 768 with 24-bit color Pentium Dual Core 2.3 GHz One available USB port One standard factory installed Ethernet connection, if network connection is desired Internet Explorer 4 or higher must be installed for the online Help to function Technical Specifications Carrier Gas (O 2 ) Power Requirements Height Width Depth Weight Computer Interfaces Autosampler Warranty Supplied at 15 psi 100/220 VAC, 50/60 Hz, 100W 47 cm 49.5 cm 49.5 cm 40.6 lbs (18.4 Kg) USB AS 12 month limited Leeman Labs and Elemental Analysis Our experience isn t limited to Mercury analysis alone. It extends to a variety of other techniques, with the same quality, precision, functionality and thorough engineering we ve built our reputation on. If you re seeking elemental analysis for your specific application or industry, Teledyne Leeman Labs is the solution. Inductively Coupled Plasma Optical Emission Spectrometers (ICP-OES) ICP-OES is ideal for low to trace level analysis of metals, metallic components in a very wide variety of sample matrices. Whether you need to measure sodium content of sea water or trace levels of toxic elements in drinking water, ICP is a powerful and effective tool for the job. DC Arc Spectrometer Our DC Arc Spectrometers are the ultimate solution for elemental analysis of the most challenging solid samples. The DC Arc can perform elemental analysis on samples that are difficult or nearly impossible to digest, or samples in their native form without digestion.

www.leemanlabs.com 2015 Teledyne Technologies Incorporated 110 Lowell Road Hudson, NH 03051 USA Phone: (603) 886 8400 14077_7/18