Thermo Finnigan LTQ. Specifications

Similar documents
Finnigan LCQ Advantage MAX

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment LCQ Deca XP Plus

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Thermo Scientific TSQ Quantum Ultra Ultra AM/Ultra EMR Performance Specifications

LCQ Fleet Ion Trap LC/MS n Exceptional Analytical Value

Translational Biomarker Core

Thermo Scientific LTQ Velos Dual-Pressure Linear Ion Trap

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

ABI 3200 Q TRAP LC/MS/MS System

Introduction to the Q Trap LC/MS/MS System

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

TANDEM MASS SPECTROSCOPY

Extrel is widely respected for the quality of mass spectrometer systems that are

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

Mass Spectrometry in MCAL

Introduction of Hitachi Chromaster 5610 MS Detector for High Performance Liquid Chromatograph

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

Accurate, High-Throughput Protein Identification Using the Q TRAP LC/MS/MS System and Pro ID Software

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Tandem MS = MS / MS. ESI-MS give information on the mass of a molecule but none on the structure

Types of Analyzers: Quadrupole: mass filter -part1

(Refer Slide Time 00:09) (Refer Slide Time 00:13)

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Analysis of Polar Metabolites using Mass Spectrometry

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

ICP-MS. High Resolution ICP-MS.

Information Dependent Acquisition (IDA) 1

Why Use the LCQ Advantage MS

Multi-residue analysis of pesticides by GC-HRMS

Petrochemical. Transformer Oil Gas Analysis - TOGA

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Mass Analyzers. mass measurement accuracy/reproducibility. % of ions allowed through the analyzer. Highest m/z that can be analyzed

[ instrument specifications ]

Agilent ESI and APCI sources: for polar to non-polar compounds

Analytical Instrumentation

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

microtof-q III Innovation with Integrity The bench-mark in accurate mass LC-MS/MS ESI-Qq-TOF

1. Prepare the MALDI sample plate by spotting an angiotensin standard and the test sample(s).

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

Catalysis CAPABILITIES

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Agilent G3212 GC-APCI Source

LC-MS Based Metabolomics

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Powerful Scan Modes of QTRAP System Technology

Technical Note # TN-35 amazon Ion Trap: New Performance Levels Meeting Demanding Analytical Requirements

High-Field Orbitrap Creating new possibilities

Quantitation of a target protein in crude samples using targeted peptide quantification by Mass Spectrometry

Traditional Herbal Medicine Structural Elucidation using SYNAPT HDMS

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Ion traps. Quadrupole (3D) traps. Linear traps

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Agilent G2350A Atomic Emission Detector (AED)

Thermo VG PQ EXCELL INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER

ChromTech HPLC System

Analyst Software. Automatic Optimization Tutorial

Nanoporous GaN-Ag Composite Materials Prepared by Metal-Assisted Electroless Etching

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188A

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Quan/Qual Analyses. Unmatched Confidence for. Thermo Scientific Q Exactive Orbitrap LC-MS/MS System. Identify Quantify Confirm

API Optimization, Source Design, and Other Considerations of LC/MS

IN QUALITATIVE ANALYSIS,

Fusion UV/Persulfate TOC Analyzer

Finnigan TSQ Quantum Discovery MAX

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

for the Novice Mass Spectrometry (^>, John Greaves and John Roboz yc**' CRC Press J Taylor & Francis Group Boca Raton London New York

Matching UHPLC Resolution and Speed with Agilent Ultra High Definition Q-TOF Technology

473-SHX Dew Point Mirror

Defining quality standards for the analysis of solid samples

MetWorks Metabolite Identification Software

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

The sercon group Isotope Ratio Mass

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

Varian Galaxie Chromatography Data System for Preparative HPLC

costech instruments ECS 4010 Elemental Combustion System CHNS-O

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188

FT-ICR Mass Spectrometer QUANTRA. Technical Description September quantra

LC Technical Information

Applications of LC/MS in Qualitative Drug Metabolite Studies

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

Quattro Micro - How does it work?

WADA Technical Document TD2003IDCR

A DIVISION OF ULVAC-PHI. Time-of-Flight Secondary Ion Mass Spectrometer with Parallel Imaging MS/MS for Confident Molecular Identification

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

UPLC Intact MASS Analysis Application Kit

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

Agilent s New 8800 ICP-QQQ. Transforming ICP-MS Technology

Mass spectrometry of proteins, peptides and other analytes: principles and principal methods. Matt Renfrow January 11, 2008

Rapid Distinction of Leucine and Isoleucine in Monoclonal Antibodies Using Nanoflow. LCMS n. Discovery Attribute Sciences

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Hiden HPR60 Molecular Beam Mass Spectrometer System

Transcription:

IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Thermo Finnigan LTQ Specifications The Finnigan LTQ is a high precision linear ion trap mass spectrometer that delivers unparalleled sensitivity and fast scanning. Unparalleled Sensitivity Universal Ion Max Source Dual Detectors Increased Scan Speed Advanced Data Dependent Suite System Specifications MS/MS SensitivityElectrospray Ionization (ESI) A loop injection of 2 µl of a 125 fg/µl solution of reserpine (250 femtograms, 0.375 femtomoles total sample) at a flow of 400 µl/min of 50% isopropyl alcohol/50% water will produce a minimum signal-tonoise ratio of 50:1, for the transition of the isolated protonated molecular ion at m/z 609 to the largest two product ions, when the mass spectrometer is operated at unit resolution in the full-scan MS/MS mode, scanning the product ion spectrum from m/z 165 615. Atmospheric Pressure Chemical Ionization (APCI) A loop injection of 2 µl of a 125 fg/µl solution of reserpine (250 femtograms, 0.375 femtomoles total sample) at a flow of 400 µl/min of 50% isopropyl alcohol/50% water will produce a minimum signal-to-noise ratio of 50:1, for the transition of the isolated protonated molecular ion at m/z 609 to the largest two product ions, when the mass spectrometer is operated at unit resolution in the fullscan MS/MS mode, scanning the product ion spectrum from m/z 165 615. Installation Requirements Power One 230 Vac ±10.0%, 15 Amps, 50/60 Hz, single phase, with earth ground dedicated to the instrument 120 or 230 Vac single phase, with earth ground for the data system Gas One high-purity (99% pure, flow rate 15 L/min) nitrogen gas supply for the API source One ultra high-purity helium gas supply (99.998% pure) with less than 1 ppm each of water, oxygen, and total hydrocarbons for the mass analyzer Page 1 of 5

Environment System averages 2300 W (8000 Btu/h) output when considering air conditioning needs Operating environment must be 15-27 C (59-80 F) and relative humidity must be 4-80% with no condensation Optimum operating temperature is 18-21 C (65-70 F) Dimensions/Weight MS: 56 cm 79 cm 59 cm (h w d) MS: ~120 kg Two roughing pumps: 38.6 kg each Performance Specifications Mass Range m/z 50 2000 Scan Power MSn, for n = 1 through 10 Contact Closure Start In/Out Start Out is programmable Analog Inputs One (1) analog Input (0-1 V) One (1) analog Input (0-10 V) The Finnigan LTQ is the latest innovation in the well-established Finnigan ion trap mass spectrometers. Based on novel design features including a hyperbolic segmented linear ion trap, dual detectors, radial ion ejection, and state-of-the-art electronics, the Finnigan LTQ redefines performance. The culmination of these features enables more experiments, leading to greater coverage on less sample in less time. The Finnigan LTQ incorporates the rugged Ion Max source, allowing simple toolless switching of ionization probes. The exceptional ion transmission achieved with the Ion Max source, combined with the increased ion storage capacity of the linear ion trap, novel ion ejection and detection technology, makes the Finnigan LTQ the most sensitive LC/MSn instrument available today. Unrivaled sensitivity and fast scanning serve to maximize the power of the advanced Data Dependent suite within the cross platform data acquisition software, Xcalibur. These technology improvements deliver the performance and easy-to-use features that accelerate the identification and quantification of analytes at low levels in applications such as proteomics, metabolism, and environmental studies. Hardware Features Ion Max API Source Enhanced sensitivity and ruggedness Sweep Gas reduces chemical noise 60 interchangeable ion probe orientation Removable metal ion capillary tube provides vent-free maintenance Page 2 of 5

Transfer Ion Optics Advanced multipole ion guides Split voltage quadrupole lens reduces noise High stability and ion transmission efficiency 2D Linear Quadrupole Ion Trap Mass Spectrometer Analyzer dimensions optimized for ultimate performance Regulated helium flow for stable performance Automatic system calibration and optimization Radial ion ejection Vacuum System Differentially-pumped vacuum system to 10-5 Torr Split-flow turbomolecular pump controls vacuum in three regions Dual rotary vacuum pump configuration High-vacuum machined aluminum analyzer chamber Detection System Patented dual conversion dynode detector Two off-axis continuous dynode electron multipliers with extended dynamic range Digital electronic noise discrimination High-efficiency radial ion ejection Integrated Divert Valve Fully-automated data system control enables user to switch the solvent front, gradient end point and any other portion of the HPLC run to waste User-definable default state of the valve, either to waste or to source Integrated Syringe Pump Syringe Pump allows automated infusion under data system control Options ESI source compatible with liquid flow rates of <1 µl/min to 1 ml/min, without splitting APCI/APPI source compatible with liquid flow rates of 50 µl/min to 2 ml/min, without splitting APCI source compatible with liquid flow rates of 50 µl/min to 2 ml/min, without splitting Metal needle option for high and low-flow analyses 96-position sample plate AP MALDI for automated and manual data acquisition NanoSpray source supports both static and dynamic nanospray experiments, compatible with liquid flow rates of 50 nl/min* to 2 µl/min *Lower limit is dependent on gauge of needle used Software Features Data System Xcalibur processing and instrument control software LCQUAN quantification package Page 3 of 5

Microsoft Office XP software package Microsoft Windows XP operating system High-performance PC with Intel Pentium microprocessor High-resolution LCD color monitor Scan Functions Full-scan feature provides full-scan mass spectra for sensitive analyses and produces spectra for rapid screening of unknown compounds Selected Ion Monitoring (SIM) monitors selected ions for target compound analysis Full-scan MS/MS produces full-scan product ion spectra at sensitivities higher than any ion trap mass spectrometer Selected Reaction Monitoring (SRM) for a traditional LC/MS/MS quantitative analytical experiment MSn for multi-stage MS experiments to probe the structure of ions ZoomScan, a high-resolution, full-range scan to resolve isotopic envelopes which is often used for charge state determination of peptides and ionization state determination of organometallics Ultra ZoomScan for ultimate resolution TurboScan, an ultra-fast scan to improve signal-to-noise and sampling rate Exclusive Technologies Unique, patented Automatic Gain Control (AGC) ensures that the ion trap is always filled with the optimum number of ions for any scan type Dynamic Exclusion allows acquisition of MS/MS and MSn spectra from lower intensity ion species WideBand Activation fragments the water loss ion within an MS/MS spectrum, generating more structurally informative spectra Normalized Collision Energy compensates for the mass-dependent energy deposition characteristics of ion trap mass spectrometers in MS/MS experiments, providing reproducible data from instrument to instrument Advanced Data Dependent Experiments Data Dependent features trigger acquisition of MSn spectra only when a compound of interest is detected Isotopic Data Dependent scanning software triggers MS/MS scanning only when a specified isotopic pattern is detected. Performs MS/MS only when a user-defined isotopic pattern is detected Triple Play determines the charge state and MS/MS scan range of a multiply charged ion Nth Order Triple Play allows the number of ions undergoing a Triple Play to be defined Ion Mapping automatically generates a 3-dimensional MS/MS map, yielding product ion, precursor ion, and neutral loss information. Ion Mapping Browser software for viewing data generated by Ion Mapping experiments Data Dependent Ion Tree performs MSn experiments on up to 25 species Data Dependent Zoom Map generates sequential MS/MS experiments using a ZoomScan for charge state determination prior to each MS/MS experiment Page 4 of 5

MSn Browser software for viewing data generated by Data Dependent Ion Tree and Ion Mapping experiments Optional Application-Specific Software BioWorks /SEQUEST /TurboSEQUEST protein identification tools Mass Frontier spectral interpretation and classification software to identify unknowns Metabolite ID rapid review and reporting of drug metabolism data DeNovoX automatically sequences unknown peptides. IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Page 5 of 5