TF / TF -Ex Field mounted temperature transmitter, Profibus PA, Pt 00 (RTD), thermocouples, or independent channels 0/-8.70 EN According to PROCESS FIELD BUS 0Input Resistance thermometer (,, -wire method) Thermocouples Resistor remote signalling units (0...00 Ω, 0...000 Ω) Voltages, mv (... mv) Output Profibus PA profile.0, Type A and B Bus design acc. to IEC 8-,. kbit/s Electrical isolation (I/O) Digital, long-term solid processing of measuring values Customer-specific linearization Continuous sensor and self-monitoring Explosion protection approvals: intrinsically safe EEx ia IIC T Flameproof version (acc. to zones): ATEX, FM, CSA Explosion Proof version (acc. to divisions): FM, CSA Input functionality or channels Redundancy Average value Differential value EMC acc. to EN 008- and NAMUR recommendation NE Reverse voltage protection and solid bus current limitation Parameterization Local parameterization allows quick commissioning PC software SMART Vision FDT/DTM technology years warranty ABB Instrumentation
TF / TF -Ex 0/-8.70 EN Technical data Output Digital output signal Profibus PA profile.0 type A and B Transmission rate (Baude rate). kbit/s Max. current consumption.8 ma Max. current in case of device failure ma Damping (programmable) t = 0...0 s Input Resistance (temperature linear) Resistance thermometer Pt 0...Pt 00...Pt 000 Resistance 0...00 Ω=/ 0...000 Ω Line resistance (R W ) per core < Ω Measuring current 00 µa Sensor short-circuit < Ω (for RTD) Sensor break > MΩ Thermocouples Types B, C, D, E, J, K, L, N, R, S, T, U Voltages mv... mv Sensor monitoring current 00 µa Input resistance MΩ Input filter 0/0 Hz Internal reference junction Pt 00, programmable Power supply (at transmitter terminals) Supply voltage, poling protected U s = 9... V DC for explosion protection application U i =...7. V DC ) Procentage related to measuring range General characteristics Rise time < 0... s Vibration resistance Vibration in operation g acc. to DIN IEC 8 part - Electrical isolation (I/O). kv Environment conditions Ambient temperature range 0...8 C Transport and storage temperature 0...00 C Relative humidity < 00 % (00 % humidtiy with isolated terminals only) Condensation permitted Characteristics at rated conditions ) (acc. to IEC 770, related to C) Measuring error incl. characteristic deviation Pt 00/resistance measurement typ. < 0. % min. < Thermocouple/mV typ. < 0 µv Additional influence of the internal reference junction Pt 00 DIN IEC 7 cl. A Mechanical construction Housing material aluminium / stainless steel Type of protection IP / IP 7 Color (EPOXY) light grey (RAL 900) Weight. kg (without accessories) Electrical connection Thread M0 x. / NPT, / NPT, / GK Cable glands (cable,...8,7 mm) cf. ordering information Ground screw ext./int. mm M /. mm M Terminals. mm, screw terminals Standard IEC 8- DIN 70 W, ASTME 998 Thermocouple Type C IEC 7 ) / DIN 70 Input element Sensor Measuring range Basis Measuring error Thermocouple Type B 00...80 C (+7...+08 F) 0.8 K Thermocouple Type E 00...000 C ( 8... 8 F) Thermocouple Type J 00...00 C ( 8...+9 F) Thermocouple Type K 80...70 C (...+98 F) Thermocouple Type R 0...70 C ( 8...+00 F) 0.8 K Thermocouple Type S 0...70 C ( 8...+00 F) 0.8 K Thermocouple Type T 00... 00 C ( 8...+ 7 F) Thermocouple Type N 80...00 C ( 9...+7 F) Thermocouple Type L 00... 900 C ( 8...+ F) Thermocouple Type U 00... 00 C ( 8...+ F) 0...+ 00 C (...+7 F) 0,8 K Thermocouple Type D 0...+ 00 C (...+7 F) 0,8 K Resistance thermometer Pt 00 Resistance thermometer Pt 000 Resistance thermometer Pt 00/ PT 000 00... 80 C ( 8...+ F) 00... 80 C ( 8...+ F) 00... 0 C ( 8...+ 8 F) 0. K 0. K (oc = 0,008) DIN 70 Resistance thermometer Ni 00 0... 0 C ( 7...+ 8 F) (a = 0,008) Resistance,, -wire 0...00 Ω, 0...000 Ω 0.0 % Voltage mv... mv 0 µv Page of 0.000
TF / TF -Ex 0/-8.70 EN Technical data Explosion protection (in preparation) Intrinsically safe (ATEX) II G EEx ia IIC T EC certificate ZELM 99 ATEX 00 Temperature class T/T < 0 C/8 C The data is based on the FISCO model written by PTB Supply circuit Output [ib] Input [ia] Max. voltage U i <7. V U o <.9 V Short-circuit current I i < 0 ma I o < 7 ma Max. power P i <. W P o < mw Internal inductance L i = 7 µh neglectable Internal capacitance C i =. nf neglectable Pressure-proof encapsulated ATEX (PTB) II G EEx d IIC T Temperature class T/T/T <0 C/ C/8 C Flameproof certification acc. to zones FM: Class I, Zone, AEx d IIC T CSA: Class I, Zone, Ex d IIC T Explosion Proof certification (FM/CSA) acc. to divisions Class I, Div. /Div., Group A, B, C, D, T Class II, Div. /Div., Group E, F, G, T Class III, T Electromagnetic compatibility (EMC) Acc. to NAMUR NE recommendation With Pt 00 sensor Type of test Degree IEC burst to signal/ kv EN 000-- data lines EN 008- static discharge EN 000-- contact discharge to: contact plate 8 kv terminals for supply kv radiated field EN 000-- 80 MHz... GHz 0 V/m coupling EN 000-- 0 khz - 80 MHz 0 V Parameterization/structure Type of inputs ( independent channels), measuring range, input filter, damping, alarm function, limit values, compensation for ageing, saving of all data proof against mains failure. Standard parameters (factory setting) Channel Pt 00, -wire circuit L-L/L/H/H-H-Lim = -00 C/00 C/80 C/80 C damping 0 s, unit C Channel Pt 00, -wire circuit L-L/L/H/H-H-Lim = -00 C/00 C/80 C/80 C dampingn 0 s, unit C Default address Process Control System (PCS) A cyclic communication can be established with all Profibus compatible PCSs. Acyclic communication requires a Master Cl., the communication may be established on the basis of the generic slave (to be in acc. to Profile.0; only standard parameters) or a TF specific driver. Those drivers are available for following PCSs: Freelance 000 (template) Symphony (Composer via DTM) Siemens (via PDM; in preparation) Configuration-tools SMART VISION.0 (DTM; acyclic service) Quick Set (local parameter setting) Block diagram Sensor ; (T) Secondary_Value_; (T) Function Block OUT (FB_) +STATUS Transducer Block T; Temperature T; Temperature T - T ; Difference T - T ; Difference / * (T+T) Average / * (T+T) Average / Redundance Primary_Value Function Block OUT (FB_) +STATUS Secondary_Value_; (T) Function Block OUT (FB_) +STATUS Sensor ; (T) (T - T) OUT (Difference T-T) Z-07 0.000 Page of
TF / TF -Ex 0/-8.70 EN Configurator/Display (optional) Quickset (in preparation) Local configurator and display. The units is supplied by the associated transmitter. The integrated rotation mechanism of the QuickSet allows the adjustment to the individual application. The intrinsically safe approval of QuickSet (in preparation) allows the hot plugging of the unit within the hazardous zones. Parameter setting Bus address Connected sensor Copy functionality The QuickSet provides an EEPROM for the backup of the configuration data of the associated transmitter. Furthermore, the configuration data can be copied to other transmitter (only TF ). Display functionality Indication of process variables Indication of diagnostic messages Indication of the current configuration Trend-indication via bargraph Communication/Parameterization Engeneering Tool PROFIBUS PA PROFIBUS DP Z-07 T Line resistance and cable type ) Bus termination Segmentcoupler PC with PROFIBUS DP Boards is_pro Multiboard (ifak) PROFIBOARD (softing) and Software SMART Vision.0 ) The Profibus standard EN 8- requires the use of shielded bus cables. Please refer to the user manual in regards to the required shielding measures. Page of 0.000
TF / TF -Ex 0/-8.70 EN Ordering information Catalog No DM LZ/deliv. TF / TF -Ex V- W Without explosion protection TF without explosion protection 08,00 * With explosion protection Type of protection: intrinsically safe TF-Ex Zelm / ATEX II G EEx ia IIC T (Zone ) 098,00 * Type of protection: pressure-proof enclosure / explosion-proof TF -Ex d PTB / ATEX II G EEx d IIC T D 098,00 * TF -Ex d FM / CSA Class I, Div. / Div., Group A,B,C,D, T E 098,00 * Class II, Div. / Div., Group E,F,G, T Class III T Type of protection: Flameproof TF -Ex d FM Class, Zone, AEx d IIC T F 098,00 * CSA Class, Zone, Ex d IIC T Display/Construction AGLF-housing without display N AGLFD-housing with Quick Set display (on request) S a.a./o.r. * Material Aluminium A Stainless steel E a.a./o.r. * Connections with cable-screw-connection / PA-connector M0*, or pressure-proof N,00 * M-connector for Profibus PA (Turck) T 0,00 * M-connector for Profibus PA (Weidmüller) W 80,00 * Thread (without cable-screw-connection) M 0 x, /" NPT /" NPT /" GK Mounting field housing without Wall mounting (STT 7) 0,00 * Wall mounting (stainless steel),00 * Pipe mounting (STT 7) 0,00 * Pipe mounting (stainless steel) 9,00 * Programming Factory standard parameter default address S Channel : Pt00, -wire circuit, damping off, unit C L-L // L / H // H-H = -00 C // 00 C / 80 C // 80 C Channel : Pt00, -wire circuit, damping off, unit C L-L // L / H // H-H = -00 C // 00 C / 80 C // 80 C Customer-specified parameter definition K 0,00 * Certificates custom-specified certificate (on request) a.a./o.r. * Accessories SMART-Vision Software.XX on CD-ROM (German / English) 797777 a.a./o.r. * SMART-VISION manual German 797779 0,00 * English 797780 0,00 * Quick Set (indicator + address programming) 7977 a.a./o.r. * see Data Sheet -.0 Minimum hardware reuqirements: Intel 808; MHz, 8MB RAM; free hard-disk capacity; Windows 9, 98, NT metal-screw-connection EEx e or EEx d (cable-diameter, 8,7 mm) 0.000 Page of
IVE I Z-08 TF / TF -Ex 0/-8.70 EN Connection diagram + PROFIBUS PA - Output PROFIBUS PA.0 Microprocessor Reference junction Input - - K K + + + K + + K K K a) b) c) d) e) f) g) h) i) a) Resistance thermometer, -wire circuit b) Resistance thermometer, -wire circuit c) Resistance thermometer, -wire circuit d) Double resistance thermometer, -wire circuit e) Double resistance thermometer, -wire circuit f) Thermocouple g) Double resistance thermometer h) Combination resistance thermometer thermocouple i) Combination thermocouple resistance thermometer Resistance measurement analog to resistance thermometer circuits a) to f) Voltage measurement analog to thermocouples circuits f) to i) Dimensional diagram (all dimensions in mm) 90 0 WHEN T IGHT CIRCU IT S COVER A L I V E NE ABB +. C PA S OUV R IR SOUS T E NSION EN 97 M8 0 7 KEEP EXP ATMOSPHERE LOS 8 Electrical connections ~0 8 7 90 CIRCU IT S A L I V E NE PA S OUV R IR SOUS Lockscrew WHEN T E NSION 97 T IGHT EN COVER KEEP EXP ATMOSPHERE IVE LOS Thread Thread 8 Electrical connections Potential equalisation screw Z-0 ABB Automation Products GmbH Subject to technical changes. Printed in the Fed. Rep. of Germany Data Sheet 0/-8.70 EN 0.000