Direct Determination of Small Organic Acids in Sea Water by IC-MS

Similar documents
Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

Determinations of Inorganic Anions and Organic Acids in Beverages Using Suppressed Conductivity and Charge Detection

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water

Determination of urea in ultrapure water by IC-MS/MS

Determination of trace anions in concentrated hydrofluoric acid

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

Time Savings and Improved Reproducibility of Nitrate and Nitrite Ion Chromatography Determination in Milk Samples

Dionex IonPac AS28-Fast-4µm column

Keywords Haloacetic acids, Water analysis, 2-D ion chromatography, ICS-3000

columns IonPac AS17-C Anion Exchange Column

Determination of Cations and Amines in Hydrogen Peroxide by Ion Chromatography Using a RFIC (Reagent-Free) System

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Determination of Tartaric Acid in Tolterodine Tartrate Drug Products by IC with Suppressed Conductivity Detection

Separation of heat stable amine salts in methyldiethanolamine (MDEA) solutions using high-pressure IC

Efficient Separations Obtained by Using Smaller Particle Size Analytical Columns with a High-Pressure Ion Chromatography System

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

New Developments in Capillary Ion Chromatography using 4 μm Columns and Charge Detection

Thermo Scientific. Anion-Exchange Column

Thermo Scientific Dionex IonPac AS23 Anion-Exchange Column

columns IonPac AS22 Anion-Exchange Column

Determination of Methylamine in Drug Products

Determination of an anionic fluorochemical surfactant in a semiconductor etch bath

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

Utility of the Charge Detector in Ion Chromatography Applications

Determination of Bromate in Bottled Mineral Water Using the CRD 300 Carbonate Removal Device

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Determination of silicate in high-purity water using ion chromatography and online sample preparation

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Thermo Scientific Dionex IonPac AS25 Anion-Exchange Column. Minutes

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Superior Chromatographic Performance Recommended anion-exchange column for separation of haloacetic acids prior to MS or MS/MS detection

columns IonPac AS18 Anion-Exchange Columns

Inline sample preparation for the determination of anions in sodium hydroxide

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Determination of Silicate in High Purity Water Using Ion Chromatography and AutoPrep

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

The determination of trace anions in concentrated phosphoric acid

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column

Sensitive HPLC Method for Triterpenoid Analysis Using Charged Aerosol Detection with Improved Resolution

Thermo Scientific Dionex IonPac AS26 Anion-Exchange Column

Monitoring Protein PEGylation with Ion Exchange Chromatography

Determination of Trace Anions in Organic Solvents

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Enhancement of Linearity and Response in Charged Aerosol Detection

Thermo Scientific Dionex IonPac AS24A Anion-Exchange Column

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

Advances in Sample Preparation for Accelerated Solvent Extraction

columns IonPac SCS 1 Silica Cation Separator

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Frank Steiner, Michael Heidorn, and Markus M. Martin Thermo Fisher Scientific, Germering, Germany

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

Application Note 187. Brian DeBorba and Jeff Rohrer Thermo Scientific, Sunnyvale, CA, USA

Determination of trace anions in high-nitrate matrices by ion chromatography

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

anion-exchange column

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

The Determination of Trace Anions in Concentrated Phosphoric Acid

Simultaneous Determination of Pharmaceutical Peptides and Acetate Counterions by HPLC Using a Mixed-Mode Weak Anion-Exchange Column

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

Determination of Organic Acids and Inorganic Anions in Lithium-Containing Boric Acid-Treated Nuclear Power Plant Waters

Determination of trace anions in concentrated glycolic acid

Fitting of ETD Rate Constants for Doubly and Triply Charged Ions in a Linear Ion Trap

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

Quantitation of Surfactants in Samples by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

Application of Eluent Generation for Trace Anion Analysis of Borated Waters

Thermo Scientific Dionex IonPac AS11-HC-4µm Anion-Exchange Column

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Direct Analysis of Surfactants using HPLC with Charged Aerosol Detection

Accurate and Reproducible Determination of Organic Halogens Using Combustion Ion Chromatography

Determination of trace anions in organic solvents using matrix elimination and preconcentration

New Stationary Phases for Solid-Phase Extraction. Pranathi R. Perati, Rosanne Slingsby, and Carl Fisher Thermo Fisher Scientific, Sunnyvale, CA, USA

Determination of Inorganic Anions in Drinking Water by Ion Chromatography

Determination of Trace Anions in Concentrated Bases Using AutoNeutralization Pretreatment and Ion Chromatography

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

Expanded capabilities in ammonium and amine detection

Determination of trace anions in high-purity waters by high volume/direct injection ion chromatography

Automated Large-Volume Injection for Direct Analysis of Alkylphenols and Ethoxylated Alkylphenols by Mixed-Mode Chromatography and Mass Spectrometry

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

Comprehensive Neurochemical Profiling of Brain Tissue Samples

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Novel Electrodeionization Devices: Applications in Inorganic Analysis

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

HILIC Method Development in a Few Simple Steps

Overcoming Challenging Matrices in Ion Chromatography

Fast methods for the determination of ibuprofen in drug products

Transcription:

Direct Determination of Small Organic Acids in Sea Water by IC-MS Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA Application Note Key Words MSQ Plus Single Quadrupole Mass Spectrometer, Organic Acids, Environmental Application, D Analysis, Ultra Trace Anion Concentrator Introduction Studies show that low molecular weight species in aquatic environments are important sources of carbon for marine bacteria. Short-chain organic acids in the marine environment play important roles in adjusting the ph value, forming a variety of complexes and then increasing the solubility of trace metals in sea water. In light of the significant growth in aquaculture for farmed fish and shellfish, several feed additives including acidifiers consisting of organic acids and their salts may provide promising alternatives to the use of in-feed antibiotics in aquaculture. Previously, analyses for organic acids in aqueous matrices have been accomplished using gas chromatography (GC) methods with derivatization; this allows fisheries to monitor the water environment and control its impact on the health of the fish. However, direct analysis by ion chromatography-mass spectrometry (IC-MS) provides a faster, more direct approach that does not require sample pretreatment. Goal To demonstrate a D-IC-MS system that allows low levels of small organic acids (C 5) to be analyzed in a high-ionic-strength matrix. The first dimension of the system separates the low-level analytes from the matrix while the second dimension resolves each of the target analytes. The mass spectrometer confirms identity and achieves low detection limits for a sensitive and selective assay. Equipment Thermo Scientific Dionex ICS- or ICS-5 Reagent-Free analytical scale IC (RFIC) system, including: DP Dual Pump EG Eluent Generator EGC III KOH Eluent Generator Cartridges, quantity two DC Detector/Chromatography Compartment with AM Automation Manager CR-ATC Continuously Regenerated Anion Trap Column, quantity two ASRS Anion Self-Regenerating Suppressors, quantity two CD Conductivity Detector, quantity two AS-AP Autosampler Thermo Scientific MSQ Plus Single Quadrupole Mass Spectrometer Dionex AXP-MS Auxiliary Pump Thermo Scientific Dionex Chromeleon Chromatography Data System software version 6.8, SR Chromatographic Conditions Columns: First Dimension Thermo Scientific Dionex IonPac AG4 Guard Column ( 5 mm) Dionex IonPac AS4 Analytical Column ( 5 mm) Second Dimension Dionex IonPac AG Guard Column ( 5 mm) Dionex IonPac AS-HC Analytical Column ( 5 mm) Dionex IonPac UTAC-ULP Ultra Trace Anion Concentrator Ultralow Pressure (5 mm)

Mobile Phase: Two Electrolytically Generated KOH Gradients Gradient : Time (min) Conc (mm) -5... 5. 6.9 6.. Gradient : Time (min) Conc (mm) Flow Rate: Inj. Volume: 5 µl Temperature: 5 C -5... 4 8. 6. 6..4 ml/min for both st and nd dimensions Detection: Suppressed conductivity: Dionex ASRS Anion Self-Regenerating Suppressor, mm, external water mode ( ml/min) Suppressor : Time (min) Current ma -5. 5. 5. 6 8. 5 Suppressor : Time (min) Current ma MS Parameters ESI: SIM Scans: N Pressure: -5.. 8. 6 6. 4 Negative ion.7 m/z span, dwell time. s/scan 8 psi Probe Temperature: 5 C Needle Voltage: 4 kv Scan Parameters: Name Mass (m/z) Cone Voltage (V) Acetate 44.9 5 Formate 58.9 45 Propionate 7. 45 Butyrate/pyruvate 86.85 45 Valerate.85 45 Plumb the two divert valves in the Automation Manager after the CD detectors. One valve enables the D system to operate; the other valve directs unwanted compounds away from the mass spectrometer. Add a flow of.4 ml/ min of acetonitrile via a low-volume mixing tee prior to the mass spectrometer (see Figure ) to aid with the thermally assisted pneumatic nebulization of the electrospray ionization (ESI) source. D-IC Valve (Eluent Flow) Time (min) Position -5 Trap column connected to Dionex IonPac AS-HC column Trap column connected to Dionex IonPac AS4 column 8 Trap column connected to Dionex IonPac AS-HC column MS Divert Valve (Eluent Flow) Time (min) Position -5 To waste 8 To mass spectrometer 8 To waste Chemicals and Reagents Sodium acetate (Fluka P/N 779) Sodium formate (Sigma-Aldrich P/N 754) Propionic acid (Sigma-Aldrich P/N P86) Sodium butyrate (Sigma-Aldrich P/N B5887) Valeric acid (Sigma-Aldrich P/N 47) Pyruvic acid sodium salt (Kodak P/N 879) Sodium propionate-d 5 (CDN Isotopes P/N D-578) Acetonitrile, HPLC grade (Honeywell Burdick & Jackson P/N AH5-4) Deionized (DI) water, 8. MΩ-cm resistivity Synthetic sea water (SW): prepare from a commercially available synthetic sea salt (Instant Ocean Sea Salt) by dissolving g of salt into L of DI water Prepare a primary stock solution of each of the six organic acids at µg/ml (ppm) in DI water. Prepare a mixture of the six acids at ppm in DI water. Prepare working stock solutions by diluting the primary stock mixture to ppm and ppb concentrations in both DI and SW. Prepare calibration standards by using the DI water mixture stocks. Prepare SW samples by dilution of the SW stock.

Table. Summary of results for organic acids analysis % Recovery in DI Water Compound Corr. Coeff. MDL (ppb) ppb ppm Acetate 99.99 88 Formate 99.995 Propionate 99.99 5.5 99 Butyrate 99.998 7.8 9 96 Pyruvate 99.99 5.6 5 7 Valerate 99.987.8 9 8 Calibration Prepare the mixture of six organic acids in synthetic SW at concentrations: 5,,, 5,,, and 5 ppb; and,, and 5 ppm. Spike an internal standard of propionate-d 5 at ppb into each of the standards. Full-loop injections of 5 µl will yield a total amount of 5 pg to 5 ng loaded on column. Prepare samples in DI water spiked at ppb and ppm to evaluate the recovery efficiency of the system (Table ). Chromatography The SW matrix necessitates use of a D-IC analysis. In the first dimension, the Dionex IonPac AS4 column weakly retains the organic acids but retains the inorganic components more strongly. Thus, the early eluting organic acids can be trapped onto a Dionex IonPac UTAC-ULP trap column. A primary divert valve (Divert Valve in Figure ) controls flow to the Dionex IonPac UTAC- ULP trap column, allowing trapping from the Dionex IonPac AS4 column initially, and then connecting the trap cartridge to the Dionex IonPac AS-HC column flow path at a later time to allow for separation and analysis of just the organic acids. A secondary divert valve (Divert Valve in Figure ) allows analytes eluting from the Dionex IonPac AS-HC column to be directed to the mass spectrometer for detection but directs flow to waste at all other times to reduce the chance of background or matrix affecting the ESI spray interface. Pump- Divert Valve Concentrator Dionex IonPac UTAC-ULP EGC- (KOH) Analytical Column Dionex IonPac AG & AS-HC Dionex ASRS Anion Self-Regenerating Suppressor ( mm) Suppressor- AS-AP Autosampler CD- External Water Divert Valve Static Mixing Tee MSQ Plus Mass Spectometer. ml/min CH CN Dionex AXP-MS Auxiliary Pump CD- Injection Valve Suppressor- Dionex IonPac AG & AS4 EGC- (KOH) Pump- Dionex ASRS Anion Self-Regenerating Suppressor ( mm) Matrix Elimination Column Injection Loop Figure. Schematics for D-IC-MS system

4 Set the two IC channels so that while one column is used for separation of the analytes, the other column is being cleaned and equilibrated for the next sample. After the analytes elute off the Dionex IonPac AS4 column and the primary divert valve changes position so that the Dionex IonPac AS4 column is then connected directly to waste, rapidly increase the eluent strength and hold it at high concentration to quickly wash off inorganic components. Simultaneously raise the suppressor current to compensate for increased eluent concentration and maintain suppressed conditions. Then return the eluent strength to starting conditions and allow the column to equilibrate while completing the analysis on the Dionex IonPac AS-HC column., Trap first 7 min onto Dionex IonPac UTAC-ULP 6. Return suppressor current to its lower level for better baseline stability while eluent concentration is low during analyte elution. Likewise, while the Dionex IonPac AS-HC column is equilibrating for the next sample, the Dionex IonPac AS4 column will be loading the trap cartridge (Figure ). By overlapping functionality in this way, the total run time for multiple samples is reduced. Mass Spectrometry The aim of the study was to develop a selective and sensitive method for direct analysis of trace levels of small organic acids in sea water samples. The mass spectrometer provides inherent selectivity based on m/z, and operation in selected ion monitoring (SIM) mode provides increased sensitivity and specificity. All of the acids ionized easily in the ESI source and ionization parameter optimization was straightforward. Each individual analyte was evaluated with respect to cone voltage, whereas a single needle voltage and probe temperature were chosen to give the best compromise in overall results. Optimal parameters are recorded in the Chromatographic Conditions section. The SIM dwell times were chosen to provide sufficient acquisition rates to yield good peak shape given the chromatographic width of the peaks. Dwell time is a compromise: longer times result in greater signal accumulation and better signal-to-noise ratio (S/N), but reduce the number of points across the chromatographic peak. Narrow chromatographic peaks require shorter dwell times for sampling to sample enough data points to accurately characterize the peak. Optimal parameters for MS analysis are instrument- and compound-dependent; therefore, chemists wishing to repeat these experiments are advised to evaluate all acquisition parameters to determine optimal values for different systems and analytes. Results and Discussion The result of the optimized analysis was sufficient separation of the analytes from the background matrix, thus allowing low-level sensitivity by mass spectrometric detection while maintaining a rugged overall analysis (Figure ). Calibration curves and limits of detection are enumerated in Table.. Chloride. Sulfate 5.. - EGC_.Concentration:. mm.5 5 7.5.5 5 7.5.5 5 7.5.5 6 Figure. First dimension (Dionex IonPac AS4 column) 9.78. Acetate 4. Butyrate. Propionate 5. Pyruvate. Formate 6. Valerate 4 5 -.47 5. 6 7 8 9 4 4.74 EGC_.Concentration: 4.. mm. -.5 5 7.5.5 5 7.5.5 5 7.5.5 6 Figure. Second dimension (Dionex IonPac AS-HC column) 6 6.

Method Performance Selectivity for the six organic acids was established through use of SIM scans on the pseudo-molecular ion (M-H)- (Figure 4). When combined with chromatographic retention times, this ensured accurate identification of the analytes. Run-to-run precision and accuracy was evaluated by nine replicate injections of a low-level standard at ppb. Method detection limits (MDLs) for propionate, butyrate, pyruvate, and valerate were estimated using the standard deviation obtained and the following equation: MDL = S t 99%, n - = 8 where S is the standard deviation and t is the Student s t at 99% confidence interval. MDLs for acetate and formate were based on the minimum level needed to achieve a S/N. Carryover was evaluated by injecting sample blanks (DI water) after a 5 ppm standard chromatographic run. All analytes in the carryover analysis were below the MDLs. This method illustrates that good separation can be achieved with use of the Dionex IonPac AS4 and AS-HC columns. When combined with the selectivity and sensitivity of the MSQ Plus Mass Spectrometer, this approach provides accurate identification and quantification of each compound. Conclusion This analysis for small organic acids, using a D-IC system, allows low levels of target analytes to be detected in a high-background matrix. The MSQ Plus Mass Spectrometer provides additional selectivity and sensitivity through use of the SIM function to achieve low detection limits. No special sample preparation was required and the results show good precision and reproducibility. References. Robinson, G. G.; Hendzel, L. L.; Gillespie, D. C. A Relationship Between Heterotrophic Utilization of Organic Acids and Bacterial Populations in West Blue Lake, Manitoba. Limnol. Oceanogr. 97, 8, 64 69.. Lückstädt, C. The Use of Acidifiers in Fisheries and Aquaculture. Partially based on the book chapter entitled: Effect of organic acid containing additives in worldwide aquaculture sustainable production the non-antibiotic way. In Acidifiers in Animal Nutrition; Lückstädt, C., Ed.; Nottingham University Press: Nottingham, United Kingdom, 7. [Online] www. wfish.de/fulltext/efeedlink-com_use_of_acidifiers_in_ fisheries_and_aquaculture.pdf (accessed April, ). Application Note 9,. Acetate. Propionate. Formate 4. Butyrate 5. Pyruvate 6. Valerate 4 5 6 4, counts counts -, 6 8 Figure 4. SIM traces from MS -5, 4 www.thermoscientific.com Thermo Fisher Scientific Inc. All rights reserved. ISO is a trademark of the International Standards Organization. Instant Ocean is a registered trademark of Spectrum Brands. Sigma-Aldrich is a registered trademark of Sigma-Aldrich Co. LLC. Fluka is a trademark of Fluka Analytical. Kodak is a trademark of Eastman Kodak Co. Corp. CDN Isotopes is a registered trademark of C/D/N Isotopes Inc. Honeywell Burdick & Jackson is a trademark of Honeywell International Inc. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. This information is presented as an example of the capabilities of Thermo Fisher products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Thermo Scientific Dionex products are, designed, developed, and manufactured under an ISO 9 Quality System. U.S./Canada (847) 95 75 Australia (6) 94 5 Austria (4) 66 5 5 Benelux () 68 9768 () 5 4 94 Brazil (55) 7 54 China (85) 48 8 Denmark (45) 6 6 9 9 France () 9 Germany (49) 66 99 India (9) 764 75 Ireland (5) 644 64 Italy (9) 5 6 67 Japan (8) 6 6885 Korea (8) 4 86 Singapore (65) 689 9 Sweden (46) 8 47 8 Switzerland (4) 6 5 9966 Taiwan (886) 875 6655 United Kingdom (44) 76 697 AN785 _E 7/S