RELATIONSHIP BETWEEN GEOELECTRICAL AND HYDROGEOLOGICAL PARAMETERS IN THE PLATEAU REGION OF ENUGU STATE, NIGERIA

Similar documents
Accepted 15 December, 2012

Evaluation of Ground Water Potential Status in Nkanu-West Local Government Area, Enugu State, Nigeria

Scholars Research Library

Vertical Electrical Sounding Survey for Groundwater Exploration in Parts of Anyigba and its Environs, in the Anambra Basin of Nigeria

Analysis of electrical resistivity data for the determination of aquifer depth at Sapele RD in Benin city

Geophysical Study of Limestone Attributes At Abudu Area of Edo State, Nigeria

Vertical electrical sounding (VES) for subsurface geophysical investigation in Kanigiri area, Prakasam district, Andhra Pradesh, India

Scientific Research Journal (SCIRJ), Volume IV, Issue XI, November ISSN

Geoelectric Evaluation of Groundwater Potential: A Case Study of Sabongida-Ora and Environs, Southern Nigeria

11/22/2010. Groundwater in Unconsolidated Deposits. Alluvial (fluvial) deposits. - consist of gravel, sand, silt and clay

Geophysical Investigation: A Case Study of Basement Complex, Nigeria

GEOELECTRICAL INVESTIGATION OF GROUNDWATER CONDITION IN OLEH, NIGERIA

Scholars Research Library. Geophysical investigation of effects of topographic complexities on groundwater potential in Ibusa, Delta State Nigeria

Groundwater Assessment in Apapa Coast-Line Area of Lagos Using Electrical Resistivity Method

1-D Electrical Resistivity Survey For Groundwater In Ketu-Adie Owe, Ogun State, Nigeria.

Surface Geophysics Character of Maastrichtian - Danian Sediments in parts of Udi - Ezeagu Area, Southern Anambra Basin, Nigeria

Geophysical Investigation of Ground Water Using Vertical Electrical Sounding and Seismic Refraction Methods

Assessment of Ground Water in a Part of Coastal West Bengal using Geo-Electrical Method

RESISTIVITY IMAGING AND BOREHOLE INVESTIGATION OF THE BANTING AREA AQUIFER, SELANGOR, MALAYSIA. A.N. Ibrahim Z.Z.T. Harith M.N.M.

Petrographic, Well Logging and Well Log Analysis of a Wellbore at Umueze in Orlu, Southeastern Nigeria

Underground water exploration of Oleh, Nigeria using the electrical resistivity method

Groundwater Exploration In Parts Of Mangu- Halle North-Central Nigeria.

Evaluation of Subsurface Formation of Pabna District, Bangladesh

Vertical Electrical Sounding (Ves) For The Determination Of Under Ground Resistivity In Part Of Nigeria Wilberforce Island,Amassoma, Bayelsa State

Soils, Hydrogeology, and Aquifer Properties. Philip B. Bedient 2006 Rice University

IJSER. Keyword: Hydraulic conductivity, transmissivity, groundwater, aquifer, groundwater,vertical electrical sounding (VES).

A surficial. P^HiHI waste disposal site, Bureau County, Illinois. east of the Sheffield low-level radioactive. electrical resistivity survey

International Journal of Scientific & Engineering Research, Volume 7, Issue 3, March ISSN

Determination of Thickness of Aquifer with Vertical Electrical Sounding

' International Institute for Land Reclamation and Improvement. 2 Groundwater Investigations. N.A. de Ridder'? 2.1 Introduction. 2.

Elijah Adebowale Ayolabi, Ph.D. 1, Adetayo Femi Folorunso, M.Sc. 2*, Ayodele Franklin Eleyinmi, B.Sc. 1, and Esther O. Anuyah, B.Sc.

Groundwater Exploration of Lokpaukwu, Abia State Southeastern Nigeria, Using Electrical Resistivity Method

Student, Department of Earth Sciences, IIT Roorkee, Uttarakhand, India, b

SUITABILITY OF ELECTRICAL RESISTIVITY SURVEY FOR SELECTING ANICUT SITE IN ORDER TO AUGMENT GROUND WATER A CASE STUDY

6.1.6 Sampling, Measurement and Testing. 1) Sampling

Integration of Electrical Resistivity and Induced Polarization for Subsurface Imaging around Ihe Pond, Nsukka, Anambra Basin, Nigeria.

GSJ: Volume 6, Issue 4, April 2018, Online: ISSN

Aspects of Geophysical Exploration for Groundwater Using Vertical Electrical Sounding (VES) in Parts of University of Benin, Benin City, Edo State

Land subsidence due to groundwater withdrawal in Hanoi, Vietnam

Surface Processes Focus on Mass Wasting (Chapter 10)

K. S. OKIONGBO AND G. C. SORONNADI-ONONIWU

Geophysical Surveys for Groundwater Modelling of Coastal Golf Courses

Scholars Research Library

International Journal of Basic and Applied Sciences Raibu et. al., Vol. 1 No. 2 ISSN: (A peer reviewed International Journal)

2-D Resistivity Study: The Horizontal Resolution Improvement by Introducing the Enhancing Horizontal Resolution (EHR) Technique

Ground-Water Exploration in the Worthington Area of Nobles County: Summary of Seismic Data and Recent Test Drilling Results

AN INTEGRATED GEOPHYSICAL INVESTIGATION OF A SPRING IN IBUJI, IGBARA-OKE, SOUTHWESTERN NIGERIA.

Characterization of Transmissivity Attributes of Fractured Aquifers from Geo-electrical models: Matuu, Kenya 1*

Hydro-Geophysical Investigation of the Federal Housing Estate Akure, Southwestern Nigeria

The Use of Vertical Electrical Sounding (VES) for Subsurface Geophysical Investigation around Bomo Area, Kaduna State, Nigeria

Aquifer Vulnerability Assessment in Some Towns of Yenagoa, South-South Nigeria

Aquifer Vulnerability Investigation Using Geoelectric Method in Parts of Sapele Local Government Area of Delta State, Nigeria

Geoelectrical Investigations at Three Bridge Sites, North Nyala, Southern Darfour State, West-Sudan

Journal of Environment and Earth Science ISSN (Paper) ISSN (Online) Vol.6, No.2, 2016

Applied Physics Research Vol. 3, No. 2; November 2011

Geophysical Investigation of Egbeta, Edo State, Nigeria, Using Electrical Resistivity Survey to Assess the Ground water Potential

Ground Magnetic and Electrical Resistivity Mapping for Basement Structurs over Charnokitic Terrain in Ado-Ekiti Area, Southwestern Nigeria

AQUIFER CHARACTERIZATION AND GROUNDWATER POTENTIAL ASSESSMENT OF THE SEDIMENTARY BASIN OF ONDO STATE. Faleye, E. T. and Olorunfemi, M. O.

Evaluation of the Aquifer Characteristics of Some Parts of Orsu, South-Eastern Nigeria.

Identification of aquifer zones by VES method: A case study from Mangalore block, Tamil Nadu, S. India

Geophysical Studies for Foundation Investigation in Basement Complex. Case Study of Iloko, Osun State, Nigeria

Journal of Environment and Earth Science ISSN (Paper) ISSN (Online) Vol 2, No.3, 2012

THE MINISTRY OF ENERGY AND ENERGY INDUSTRIES MINERALS DIVISION MINE DESIGN TEMPLATE OPERATOR NAME: OPERATOR ADDRESS: PHONE NUMBER: FACSIMILE:

Subsurface Characterization using Electrical Resistivity(Dipole-Dipole) method at Lagos State University (LASU) Foundation School, Badagry

INTEGRATED GEOPHYSICAL INVESTIGATION OF SEQUENCE OF DEPOSITION OF SEDIMENTARY STRATA IN ABAKALIKI, NIGERIA ABSTRACT

Geophysical Investigation of Foundation Condition of A Site in Ikere- Ekiti, Ekiti State, South-Western Nigeria

INTEGRATED INVESTIGATION TO LOCATE A WASTE DISPOSAL AREA

Case Study: University of Connecticut (UConn) Landfill

Geoelectricity. ieso 2010

Electrical Resistivity Survey Forground Water At Eye Zheba Village, Off Bida - Minna Road

Correlation of Self Potential (SP) and Resitivity Survey Methods for Evaluation of Groundwater Potentials: Case Study of Imo State, Nigeria

Chapter 13. Groundwater

Geoelectric Investigation for Groundwater Prospects in Ejeme-Aniogor and Environs, Aniocha- South Local Government Area, Delta State, Nigeria

Application of Vertical Electrical Sounding (VES) In Delineating Ground Water Potential in Some Part of Jalingo, Taraba State North Eastern Nigeria

Relevance of 2D Electrical Imaging in Subsurface Mapping: Case Study of National Animal Production Research Institute (NAPRI), Zaria.

AN APPRAISAL OF CERTAIN CHARACTERISTICS OF AQUIFER IN CHIKUN LOCAL GOVERNMENT AREA OF KADUNA, NIGERIA

DC Resistivity Investigation of Anisotropy and Lateral Effect using Azimuthal Offset Wenner Array. a case Study of the University of Calabar, Nigeria

Determination of Incompressibility, Elasticity and the Rigidity of Surface Soils and Shallow Sediments from Seismic Wave Velocities

Use of VLF Electromagnetic and Electrical Resistivity Methods for Groundwater Investigation in Oke Amu Area, Southwestern Nigeria

Index Terms- Apparent Resistivity, Aquifer, Geoelectric Section, Piezometric Surface.

Available online at Pelagia Research Library. Advances in Applied Science Research, 2011, 2 (1):

International Journal of Scientific & Engineering Research, Volume 6, Issue 12, December ISSN

LECTURE 10. Module 3 : Field Tests in Rock 3.6 GEOPHYSICAL INVESTIGATION

Application of Resistivity Methods to Groundwater Protection Studies in Niger Delta

VOL. 3, NO. 9, September 2013 ISSN ARPN Journal of Science and Technology All rights reserved.

Derived Relations between Geoelectric and Hydraulic Parameters in Bara Basin, Sudan

CONTENTS 1. INTRODUCTION. 2. THE D.C. RESISTIVITY METHOD 2.1 Equipment 2.2 Survey Procedure 2.3 Data Reduction

Geophysical Investigation of Loss of Circulation in Borehole Drilling: A Case Study of Auchi Polytechnic, Auchi, Edo State, Nigeria

APPLICATION OF ELECTRICAL RESISTIVITY TOMOGRAPHY FOR SAND UNDERWATER EXTRACTION

K. A. Murana, P. Sule, A.L. Ahmed, E.M. Abraham and E.G. Obande. 1. Introduction

Vertical Electrical Sounding for Aquifer Characterization around the Lower Orashi River Sub-Basin Southeastern Nigeria

DETECTION OF GROUNDWATER POLLUTION USING RESISTIVITY IMAGING AT SERI PETALING LANDFILL, MALAYSIA

Groundwater Hydrology

Application of Remote Sensing and Geo-Electrical Method for Groundwater Exploration in Khor Al Alabyad, North Kordofan State, Sudan

Scholars Research Library. Predicting the aquifer characteristic within the major towns in Ndokwa land

EVALUATION OF GROUNDWATER POTENTIAL USING ELECTRICAL RESISTIVITY METHOD IN OKENUGBO AREA, AGO - IWOYE, SOUTHWESTERN, NIGERIA.

Causes of Borehole Failure in Complex Basement Terrains: ABUAD Case Study, Southwestern Nigeria. w w w. a j e r. o r g Page 192

Application of Vertical Electrical Sounding to Delineate and Evaluate the Hydrological Conditions in Baiji Tikrit Basin

Finding Large Capacity Groundwater Supplies for Irrigation


Transcription:

RELATIONSHIP BETWEEN GEOELECTRICAL AND HYDROGEOLOGICAL PARAMETERS IN THE PLATEAU REGION OF ENUGU STATE, NIGERIA *C. C. Ezeh Department of Geology and Mining, Enugu State University of Science and Technology, Enugu, Nigeria *Author for Correspondence ABSTRACT Geophysical surveys involving the use of Vertical Electrical Soundings (VES) were carried out in the vicinity of 34 boreholes in the Plateau region of Enugu State Nigeria, with an aim to relate geoelectric properties to hydrogeologic parameters. The study area lies between latitudes 6⁰ N and 7⁰ N and longitudes 7⁰ E and 7⁰30 E in the Southeastern part of Nigeria. The VES data were interpreted in terms of the apparent resistivity and thickness of subsurface layers. These parameters were then correlated with the available borehole data. Significant correlations between the transverse resistance and transmissivity as well as between the apparent resistivity and borehole yield were derived. It can be inferred from the study that the geoelectrical sounding method can used for making preliminary estimates of transmissivity and borehole yield in areas within the region where wells have not been drilled.. Keywords: Enugu Plateau, Transmissivity, Borehole Yield, Transverse Resistance, Aquifer INTRODUCTION The determination of aquifer properties is best made on the basis of data obtained from test pumping wells. These properties are important in determining the natural flow of water through an aquifer and its response to fluid extraction. An alternative approach for estimating aquifer characteristics is the use of surface geoelectrical methods. Many investigators have studied the relationship between electric and hydraulic parameters of aquifers. Mazac et al., (1985) analyzed the correlation between aquifer and geoelectrical parameters on both the saturated and unsaturated zones of the aquifers. Louis et al., (2005) estimated aquifer transmissivity on the basis of monitoring the variations of the ground water resistivity. Transmissivities, formation factors and permeability have also been estimated from empirical/semi-empirical correlations, often using simple linear relations (Kelly 1977; Schimschal, 1981; Chen et al., 2001). The analytical relations between aquifer transmissivity and Dar-Zarrouk parameters have been developed and various data sets tested (Sri Niwas and Singhal, 1981). An inverse relationship between porosity and hydraulic conductivity were used to explain the direct correlations between formation factor and hydraulic conductivity (Heigold et al., 1979; Urish, 1981). This paper presents a study that was conducted in the plateau region of Enugu State, Nigeria, to examine the relationship between hydrogeological and geophysical characteristics of the stone aquifers. The objective was to correlate surface resistivity data with aquifer properties in order to develop groundwater exploration model for the region. The Study Area The Plateau region (Nsukka-Udi-Awgu Plateau) falls within latitudes 6⁰ N and 7⁰ N and longitudes 7⁰ E and 7⁰30 E (Figure 1) The plateau is very extensive, some 48km wide in Nsukka area and 16km in Udi and Awgu (Figure 2). The region also shows undulating relief with a high central zone, which lies over 370m above mean sea level. Some isolated peaks may reach over 580m. Apart from the residual hills, the Plateau is also characterized by low density of drainage and wide, flat bottom dry valleys. The dry valleys are thought to be former river valleys that later got dried up by infiltration into the False bedded Sandstones (Ajali Sandstones). The land slopes to the east and west and there are beautiful Cuestas. The scarp face of the Cuesta is formed by resistant stones of the Lower Coal Measures (Mamu Formation), while the less Centre for Info Bio Technology (CIBTech) 18

resistant False bedded Sandstones, form the gentler upper slopes and the crest. The plateau region is associated with the Ajali Sandstone and Nsukka Formation. The stone usually underlies areas of height above 300m while the Nsukka Formation is characterized by abundant residual hills (Figure 2) Figure 1: Topographic Map of Nigeria Showing the Nsukka Udi Plateau (Wikimedia, 2015) Figure 2: Surface Map of Enugu State Showing the Nsukka Udi Plateu Centre for Info Bio Technology (CIBTech) 19

Geology Two main geologic formations outcrop in the study area. These are the Nsukka Formation (Damian) and Ajali stone (Upper Maaastritchian). The Nsukka Formation lies conformably on the Ajali stone. The formation was first described by Tattam (1944) as the Upper coal measures. The lithology is mainly interbedded shales, siltstones, s and thin coal seams which have become lateritized in many places where they characteristically form resistant cap rocks. The Ajali Sandstone (upper Maastritchian) is about 451.m thick (Agagu et al., 1985) and consists lithologically of medium to coarse grained, poorly consolidated white s with characteristic cross bedding and clay intercalations. The stone is conformably underlain by shaley units of Mamu Formation which consists of mudstone, y shale and fresh water stones and provides the shaley impermeable base on which the waters of Ajali aquifer are trapped Figure 3: Geologic Map of Enugu State Showing the Plateau Region hydrogeology The Ajali stone is the most aquiferous geologic formation in the study area followed by the y members of Mamu and Nsukka Formation. Within these formations, various hydrologic units exist as perched, water table, semi confined and confined aquifers. Well records in parts of the study area (Figures 4-5) show that the aquifers are mostly /stones with y clay and clay/shale as semiconfining aquitards or aquicludes respectively. Confined conditions exist over the Ajali stone in areas overlain by the Nsukka Formation. The various unconfined aquifer units in the study area occur in the Ajali stone. Centre for Info Bio Technology (CIBTech) 20

Semi-confined situation exists in places and usually comprise interbedded thick sequence of (aquifer) and y-clay or clayey- aquicludes (Figure 5). Various aquifers in this group occur in the upper to middle horizons of Ajali stone and in the upper section of the Mamu Formation. Perched aquifer conditions occur mostly in the lateritic/red earth cover over the Nsukka Formation and in the upper y units of the Nsukka Formation. The perched aquifer is generally thin and measurements in dug holes gave thickness values ranging from 3m to about 8m with an average of about 4.6m (Uma, 2003). 0-20- 40- Ekwegbe Ozalla Umunko Ebe Akpakume Top lateritic Lateritic Lateritic Fine top clayey clayey Med-coarse Lateritic fine Med /coarse Coarse interitic Coarse Fine/med Coarse Top lateritic Extreme coarse 60-80- Very coarse Medcoarse Extreme coarse Med/coarse 100- v. Coarse Med. Sst 120-140- Medcoarse Med - Fine-med Med-fine 160-180- Fine-medcoarse Fine/med Fine Fine 180m Med coarse Sandy clay 165m 200- V. fine-med Fine clayey 220-240- 234m Shale with Fine-mend v. Fine 260-250m 247 FIG. 3.6 WELL RECORDS SHOWING DEEP UNCONFINED AQUIFER UNITS IN THE STUDY AREA METRES Figure 4: Figure 5: Well Records Showing Deep Unconfined Units in the Study Area 280-. METRES Centre for Info Bio Technology (CIBTech) 21

0-20- 40-60- Ohebe-dim Umana Ndiuno Obeleagu Umana Top lateritic Clayey sill Brown coarse Med/coarse Clayey Fine/med Top laleritic Black shale Clay and iron stone Fine/med/coarse Fine/med/coarse Fine/med/coarse /shale Top laleritic Iron stone Coarse Reddish brown ironstone Coarse Med Med/coarse 80-100- Clayey Fine/med/ Fine / med Med coarse 120- Clayey Fine Med/coarse Med-coarse 140- Shaly 160- Fine/med Sandy clay 180- Shaly 200- Fine/med/coarse 220- Clayey and silt Med/coarse grayish Black coal with 240-234m METRES Metres 260-280- 300-266m 247m FIG. 3.7 WELL RECORDS SHOWING CONFINED AND SEMICONFINED AQUIFER UNITS IN THE STUDY AREA. Figure 5: Well Records Showing Confined and Semi Confined Units in the Study Area Heoretical Considerations The Schlumberger array method of vertical Electric Sounding VES has been used throughout this study. In the Schlumberger array, four electrodes (two current A and B and two potential M and N) are placed along a straight line on the land surface such that the outside (current) electrode distance (AB) is equal to or greater than five times the inside (potential) electrode distance (MN). Assuming the medium below the surface of the earth to be homogeneous and isotropic of resistivity l, the potentials V M and V N as measured at M and N, respectively, are given by V M = I 1 1 1 2 a b a b 2 2 V N = I 1 1 2 2 a b a b 2 2 From which 2 a b V M VN b 3 4 I Centre for Info Bio Technology (CIBTech) 22

Denoting (V M V N) by ΔV, and acknowledging the fact that, in reality, the medium is anisotropic, the apparent resistivity a measured by the Schlumberger array is given by. 2 a b V a b 4 4 I If a and b are measured in metres and V and I in millivolts and milliamperes respectively, la would be in ohm metres. Equation 4 may be written as KV a 5 I 2 a b Where, K = 6 b 4 is the geometric factor for the Schlumberger array. Keller and Frischknecht, (1966), have shown that by keeping the distance b less than 40% of a, the electric field E at the center of the spread is what is being measured by the Schlumberger array with an error of about 5%. Estimates of Longitudinal Conductance and Transverse Resistance from VES The transverse resistivity and the longitudinal conductance of the aquifer were determined from the layer parameters as: TR = hi.li 7 and S = hi/li 8 Using the relationship of Mailet (1947), where li, hi, TR and S are layer resistivity, thickness, transverse unit resistance and longitudinal conductance respectively Estimating Aquifer Transmissivity The transmissivity of an aquifer layer is the product of the hydraulic conductivity and its thickness. In the present study however, transmissivity was estimated from specific capacity data obtained from wells drilled mostly in the stone aquifers within the study area using the statistically derived linear relationship between transmissivity and specific capacity developed by Mace et al., (2000) i.e. Tr = 1.03(Sc) 1.08 9 Where Tr and Sc are the transmissivity and specific capacity respectively. Data Acquisition and Interpretation In the present study, vertical electrical soundings where conducted nearby 34 existing boreholes located in the plateau region of the state where pumping test have been conducted. The locations of the boreholes are shown in Figure 6. Survey lines were located along existing roads and paths, avoiding physical obstacles like buildings and fences, and the axes of the soundings were aligned parallel to the geologic strike in order to reduce the effects of lateral variations. Also, traverse lines were kept as straight as possible and electrical cable installations were avoided to minimize the influence of electromagnetic induction. A preliminary interpretation of the sounding curves using partial curve matching (Orellana and Mooney, 1966; Koefoed, 1979; Keller and Frischknecht, 1966) provided the initial estimates of the resistivities and thickness (layer parameters) of the various geoelectric layers which then served as starting points for fast computer-assisted interpretation based on optimization technique. The computer program OFFIX, was used to interpret all the data sets obtained. Analysis of Ves Curves The study of apparent resistivity curves prepared from the VES data show two major types of curves. These are designated as Types I and II. Type I curves comprise mainly of AH ; HA ; HAA, and Centre for Info Bio Technology (CIBTech) 23

AAK curves with layer resistivity relationships as l 1 < l 2 < l 3 > l 4; l 1 > l 2 < l 3 < l 4; l 1 > l 2 < l 3 <l 4 < l 5; and l 1 < l 2 < l 3 < l 4 > l 5 respectively, following the classification by Keller and Frischknecht (1966). Type II curves comprise mainly of AK ; AAA ; and AAAK curves with layer resistivity relationships; l 1 < l 2 < l 3 > l 4, l 1 < l 2 < l 3 < l 4 <l 5, and l 1 < l 2 < l 3 < l 4 < l 5 > l 6., respectively. The type I curve generally show (i) a relatively thin surface layer of about 1 2m thick of lateritic soil existing below the ground surface (l a between 250 and 3000 ohm-m), followed by (ii) the presence of y clay/shale in some places (l a between 500 and 2000 ohm-m) and (iii) a y formation of varying grain size (medium to coarse) and thickness. The l a values may decrease with depth depending on the saturated condition. The field curves of type I were mostly obtained from the VES conducted in the area underlain mostly by the Nsukka Formation. The type II curve is also composed of thin surface layer of lateritic soil, followed by a y formation of varying grain size and thickness. The type II curves are characterized by steeply rising terminal branch, indicating a highly resistive base (up to 40,000 ohm-m in some places). These curves were obtained from soundings conducted in areas underlain by the Ajali Formation and to a lesser extent, the Nsukka Formation. Figure 6: Map of Enugu State Showing Drainage, Borehole and VES Locations RESULTS AND DISCUSSION Geoelectric Cross-Section along N-S Axis The results of some of the sounding interpretation together with geological data were used to construct a cross-section along the N-S axis of the study area (Figures 7 & 8). A comparison of the sounding results with borehole information (Figures 4 & 5) show that the first two geoelectric layers correspond to latertic soil and y shale overburden with depths ranging from 15 to 30 metres (Figure 7). The upper part of Centre for Info Bio Technology (CIBTech) 24

this overburden contains ironstones and laterites while the lower part is made up of y shale and that is ferruginous in some places. This layer is virtually absent in Figure 8. The third (or fourth in some places) geoelectric layer, whose composition is mainly medium to fine grained s has been identified as the aquiferous layer with apparent resistivities ranging from 1700 to 30,000 ohm-m. The last is the highly resistive layer with apparent resistivities of over 30, 000 ohm-m, corresponding to geoelectric basement. LEGEND Top Lateritic Soil Sandy Shale Top Sand Geoelectric Basement Figure 7 Resistivity Profile across Ogurute to Ochima Constructed from VES LEGEND Top Lateritic Soil Sandy Shale Sand Geoelectric Basement 7 Figure 8 Resistivity Profile across Egede to Achi Constructed from VES Centre for Info Bio Technology (CIBTech) 25

YIELD (M 3 /hr) TRANSVERSE RESISTANCE (OHM-M 2 ) International Journal of Geology, Earth & Environmental Sciences ISSN: 2277-2081 (Online) Transverse Resistance Versus Transmissivity Vertical electrical soundings conducted nearby existing boreholes where well records were available allowed the determination of transmissivily values for correlation purposes. Table 1 and figure 9 show transmissivity (Tr) versus transverse resistance, (TR) plot with Tr. (m 2 /day) = 0.001TR 20.485 10 Equation 10 is an empirical relation between Tr and TR obtained by using linear regression techniques, with a correlation coefficient of 0.713, from the range of values used. The relationship suggest that the information obtained from vertical electrical sounding data can be used for pre-drilling estimation of transmissivity in the study area 2500000 2000000 1500000 1000000 500000 Tr = 0.001TR - 20.485 (R 2 = 0.713) 0 0 200 400 600 800 1000 1200 1400 1600 TRANSMISSIVITY (M 2 /DAY Figure 9: Plot of Transverse Resistance versus Transmissivity Aquifer Resistivity Versus Borehole Yield An attempt was also made to find general functional relationship between the apparent resistivity l a of the aquifer as interpreted from the Schumberger depth sounding curves and the yield of boreholes, Yd. The data on the boreholes (table 1) produced a significant correlation coefficient of 0.601 between l a and borehole yield in m 3 /h. Figure 10 show the plot of borehole yield versus aquifer resistivity. The least square regression fit between the two indicates the following empirical relationship: Yd (m 3 /h) = 0.005ρa + 54.54 11 Yd m 3 /hr = 0.005ρ a +54.94 (R 2 =0.601) 180 160 140 120 100 80 60 40 20 0 0 5000 10000 15000 20000 25000 APPARENT RESISTIVITY (OHM-M) Figure 10: Plot of Borehole Yield versus Apparent Resistivity Centre for Info Bio Technology (CIBTech) 26

Table 1: Geoelectrical and Hydrogeological Data Used for the Obtaining the Empirical Relationship S.No Borehole Transmisivity Location M 2 /Day Logitude Latitude Aquifer Resistivity (OHM-M) Transverse Resistance (OHM-M 2 ) Borehole Yield M 3 /H 1 ACHI 7.35 6.150 5550 552683 94.28 86.85 2 AGUOBUOWA 7.283 6.383 6875.33 1198142 737.07 108 3 AKPAKUME 7.300 6.650 15375.8 1335500 796.62 129.3 4 AKU 7.317 6.700 2898.5 1239937 738.57 48.2 5 AMACHRA 7.450 6.950 5760.7 952116 765.06 107.93 6 AMUFIE 7.483 6.950 6257.25 1428097 1416.95 102.44 7 AWHUM 7.400 6.550 16882.2 1024000 652.59 169.93 8 EBE 7.367 6.483 3710.59 585033 580.58 71.6 9 EDE-OBALLA 7.450 6.800 5167 727748 497.79 81.6 10 EGEDE 7.367 6.550 20000 1350000 742.14 142.5 11 EHA- 7.450 6.817 10000 650000 640.12 84.6 ALUMONA 12 EKWEGBE 7.417 6.717 5751.23 556609 300 60 13 ETTE 7.450 7.110 9072.3 843296 1068.92 92 14 1BEAGWA- 7.400 6.917 2866.47 2025083 1323.25 54.87 AKA 15 ITCHI 7.367 6.983 3035.25 573274 434.39 85.3 16 IWOLO 7.283 6.450 1424.26 1182000 597.23 55.8 17 LEJJA 7.367 6.750 9000 370000 336.29 102 18 NACHI 7.333 6.300 5108.62 349262 176.14 122.6 19 NGWO 7.400 6.417 5000 267500 91.6 82.83 20 NSUKKA 7.383 6.850 9342.5 1452195 1285.28 133.08 21 OBIMO 7.317 6.817 3038.56 175043 282.92 80 22 OBUKPA 7.400 6.900 6467.37 1340024 1221.92 99.7 23 OCHIMA 7.367 6.650 1730.5 674321 880.39 47 24 OGURUTE 7.417 6.697 3105.27 550752 434.39 79.2 25 OHEBE-DIM 7.367 6.700 5164 607126 301.51 60 26 UMABI 7.367 6.283 2977.63 1356902 1120.31 62 27 OVOKO 7.450 6.883 9453.3 672900 747.79 126.25 28 OZALLA 7.383 6.733 7927.6 653000 274.02 86.8 29 UDI 7.433 6.317 2608.07 249154 226.3 45.4 30 UGBAIKE 7.516 6.950 14107.2 1036226 680.94 108.2 31 UMANA 7.317 6.350 8523.83 802667 538.85 126 NDIUNO 32 UMUNKO 7.417 6.683 3258.9 385045 105.17 56.4 33 UNADU 7.350 7.000 2751.2 482846 530.79 108 34 IHEAKPU- AWKA 7.433 6.900 6303.13 466571 379.1 68.4 Summary and Conclusion An integrated approach of hydrogeological and geoelectrical soundings surveys has been used to study the relationship between the geoelectrical and hydraulic parameters in the Plateau region of Enugu State Nigeria. Electrical resistivity and borehole data from 34 locations were used to correlate the aquifer apparent resistivity with its borehole yield and aquifer transverse resistance (TR) with its transmissivity (Tr). Centre for Info Bio Technology (CIBTech) 27

Significant relationship exists between transverse resistance and transmissivity similarly, aquifer apparent resistivity was found to be related to borehole yield. These empirical relations developed in this study can be used for pre-drilling estimation of transmissivity and the yield of prospective boreholes in the region. REFERENCES Agagu OK, Fayose EA and Peters SW (1985). Stratigraphy and Sedimentation in the Senonian Anambra basin of Southeastern Nigeria. Nigerian Journal of Mining Geology 22(1) 25-36. Chen J, Hubbard S and Rubin Y (2001). Estimating the hydraulic conductivity at the south Oyster site from geophysical tomographic data using Bayesian techniques based on the normal linear regression model. Water Resources Research 37(6) 1603 1613. Heigold PC, Gilkeson RH, Cartwright K and Reid PC (1979). Aquifer transmissivity from surficial electrical methods. Ground Water 17 330 345. Keller GV and Frischknecht FC (1966). Electrical methods in Geophysical Prospecting. (Perganon Press: Oxford, New York USA) Kelly WE (1977). Geoelectric sounding for estimating aquifer hydraulic conductivity. Ground Water 15 420 425. Koefoed O (1979). Geosounding Principles, 1, (Elsevier, Amsterdam, Netherland) 276 Louis IF, Karantonis GA, Voulgaris NS and Louis FI (2005). The Contribution of Geophysical Methods in the Determination of Aquifer Parameters: The Case of Mornos River Delta, Greece, (Department of Geophysics and Geothermic, University of Athens, Greece, Europe) 41 Mace, R. E., Smyth, R. C., Xu, L., and Liang, J., 2000c, Transmissivity, hydraulic conductivity and storativity of the Carrizo Wilcox aquifer in Texas, The University of Texas at Austin, Bureau of Economic Geology, final report submitted to the Texas Water Development Board, 76 p. Maillet R (1947). The Fundamental equations of Electrical Prospecting. Geophysics 12 529-556 Mazac O, Kelly WE and Landa I (1985). A hydrogeophysical model for relations between electrical and hydraulic properties of aquifers. Journal of Hydrology 79 1-19. Niwas S, Singhal DC (1981). Estimation of aquifer transmissivity from Dar Zarrouk parameters in porous media. Journal of Hydrology 50 393-399. Orellana E and Mooney HM (1966). Master Tables and Curves for Vertical Electrical Sounding over Layered Structures, (Interciencia, Madrid, Spain) 193. Schimschal U (1981). The relationship of geophysical measurements to hydraulic conductivity at the Brantley dam site, New Mexico. Geoexploration 19 115 125. Tattam CM (1944). A review of Nigeria Stratigraphy Report, Geological Survey of Nigeria No 27-46. Uma KO (2003). Hydrogeology of the perched aquifer systems in the hilly terrains of Nsukka town, Enugu State, Nigeria. Water Resources Journal NAH 14 85 92. Urish DW (1981). Electrical resistivity-hydraulic conductivity relationships in glacial outwash aquifers. Water Resource Research 17(5) 1401-1408. Wikimedia (2015). Nigeria Topography. Common-wikimedia.org Centre for Info Bio Technology (CIBTech) 28