Three Axis Magnetic Field Transducer x-h3x-xx_e3d-2.5khz-1-0.2t

Similar documents
AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC6H 400-S/SP1

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC5FW 500-S

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC5FW 200-S/SP1

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

BMXART0814 analog input module M340-8 inputs - temperature

BMXART0814 analog input module M340-8 inputs - temperature

Last Revision: August,

3.3V Power Supply Isolated Current Sensor with Common Mode Field Rejection

5730A High Performance Multifunction Calibrator. Extended specifications

792A AC/DC Transfer Standard

792A AC/DC Transfer Standard

Isolated Current Sensor with Common Mode Field Rejection

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Glossary Innovative Measurement Solutions

The Hall Effect. c David-Alexander Robinson & Pádraig Ó Conbhuí. 13th December 2010

EQ-730L Linear Hall IC

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Observation of the Hall Effect, and measurement of the Hall constant of a few semi-conductors and metals samples.

Physical Structure of Matter Hall effect in p-germanium with Cobra3. Solid-state Physics, Plasma Physics.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

QUESTION BANK DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING UNIT I - INTRODUCTION SYLLABUS

Operating limits and tolerances of platinum resistance thermometers per EN 60751: 2008

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Digital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW

BMXART0814 analog input module M340-8 inputs - temperature

Physical Structure of Matter. Hall effect in p-germanium Solid-state Physics, Plasma Physics. What you need:

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,

AlphaLab Gaussmeter Model VGM -- Instructions

RATIOMETRIC, LINEAR HALL-EFFECT SENSORS

Department of Mechanical and Aerospace Engineering. MAE334 - Introduction to Instrumentation and Computers. Final Examination.

Final Report August 2010

Digital Fluxmeter CYHT700SP

473-SHX Dew Point Mirror

ELECTRICITY AND MAGNETISM, A. C. THEORY AND ELECTRONICS, ATOMIC AND NUCLEAR PHYSICS

Isolated Current Sensor with Common Mode Field Rejection

EM Simulations using the PEEC Method - Case Studies in Power Electronics

Distributing Tomorrow s Technologies For Today s Designs Toll-Free:

Direct Operated Type Solenoid Operated Proportional Directional Control Valve

Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Acceleration/Velocity/Displacement VIBRATION METER

Test Report EN (2008)

Exercise 1: Thermistor Characteristics

MAU100 Series. 1W, Miniature SIP, Single & Dual Output DC/DC Converters MINMAX. Key Features

MAU100 Series. 1W, Miniature SIP, Single & Dual Output DC/DC Converters MINMAX. Block Diagram. Key Features

Sensitivity Estimation of Permanent Magnet Flowmeter

Dynamic Models for Passive Components

Model HHG 21 GAUSS / TESLA METER

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

Magnetic field outside a straight conductor (Item No.: P )

SHM-14 Ultra-Fast, 14-Bit Linear Monolithic Sample-Hold Amplifiers

EE 3324 Electromagnetics Laboratory

MAU200 Series. 1W, High Isolation SIP, Single & Dual Output DC/DC Converters MINMAX. Block Diagram. Key Features

High-Voltage Types Ordering Information, Mica Capacitors

The Hall Effect. Introduction: The hall effect was discovered by Edwin Hall in 1879, 18 years before the discovery of the electron.

Model 5060 GAUSS / TESLA METER

Low Drift, Low Power Instrumentation Amplifier AD621

Product Data. Brüel & Kjær B. Sound Intensity Calibrator Type 3541

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

NR/RR. Set No. 2 CODE NO: NR/RR210204

CHAPTER 5 SIMULATION AND TEST SETUP FOR FAULT ANALYSIS

V, I, R measurements: how to generate and measure quantities and then how to get data (resistivity, magnetoresistance, Hall). Makariy A.

FATEK. FBs-1HLC. Precision Load Cell Module. Operation manual V1.1 06/07/2017 FATEK AUTOMATION CORP.

Switched-Capacitor Circuits David Johns and Ken Martin University of Toronto

Temperature Coefficients for DC Resistance of Match and Reference Attenuators

MAGNETIC MEASUREMENTS ON THE GUN FOCUSING SOLENOID

Plastic Film Capacitors. Metallized Polypropylene Film Capacitor E C W F D E C W F D

Impedance relay and protection assemblies

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

Nonlinear Losses in Electro-acoustical Transducers Wolfgang Klippel, Daniel Knobloch

MODEL 107 TEMPERATURE PROBE INSTRUCTION MANUAL

Sensing and Sensors: Fundamental Concepts

Louisiana State University Physics 2102, Exam 3 April 2nd, 2009.

MT3451 Series BiCMOS, Latch, Hall-Effect Magnetic Position Sensors

Part 4: Electromagnetism. 4.1: Induction. A. Faraday's Law. The magnetic flux through a loop of wire is

Configurations: Dimension (mm) A (max) Item IRS IRS

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

Introduction to Blackbody Sources

LM /LM /LM Micropower Voltage Reference Diode

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Recommended Land Pattern: [mm]

Usage limitations and accuracies of platinum resistance thermometers (DIN EN 60751:2009) in industrial applications

Chapter 14: Inductor design

Thermal Parameter Measurement AN 18

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

LEP Hall effect in p-germanium with Cobra3

Measurements in Mechatronic design. Transducers

473 Dew Point Hygrometer

Test System Requirements For Wafer Level MRAM Test

Surface Mount Chip Capacitors

MAX TEMPCO (ppm/ C) INITIAL ERROR (mv)

Power Resistors, for Mounting onto a Heatsink Thick Film Technology

Prepare for this experiment!

Transcription:

DESCRIPTION: TYPICAL APPLICATIONS: The is a high accuracy magnetic flux density-toanalogue-voltage transducer with a highlevel and temperature compensated output signal for each of the three components of the measured magnetic flux density. The temperature measurement feature allows user to take temperature readings while monitoring the magnetic field. The transducer consists of two modules (as shown in Fig.1): 1. Hall probe Module H, and 2. Electronics Module E. To build up a complete measurement system the module E needs to be connected with an adequate power supply and three voltmeters. Quality control and monitoring of magnet systems (generators, motors, etc.); Quality control of permanent magnets; Development of magnet systems; Mapping magnetic field; Process control; Application in laboratories and in production lines, etc. Connector CoP DC Power input Field Sensitive olume (FS) SENSITIITY: /T Connector CoS Field Signals output pt Technoparkstrasse 1, CH-8005, Zurich Fax: +41 (79) 366 87 56, Email: info@senis.ch http://www.senis.ch Cable CaH Module E Module H Figure 1. Schema of the SENIS s high-accuracy Hall Magnetic Field Transducer: - Module H, consisting of the Hall Probe and the CaH Cable; - Module E, Analog electronics for signal conditioning. Note: Fixed (non-detachable) CaH cable connection to the transducer s electronic module. Page 1 / 7

SPECIFICATIONS: Unless otherwise noted, the given specifications apply for all three B-measurement channels X, Y and Z at room temperature (23 C) and after a device warm-up time of 3 minutes. Magnetic & Electrical Device Properties: Parameter alue Remarks Maximum (full scale) magnetic flux density (±B FS ) Linear range of magnetic flux density (±B LR ) ± 0.4 T (± 4 kg) No saturation of the outputs ± 0.2 T (± 2 kg) Calibrated range Accuracy < 1.0% of B LR See note 1 Output voltages ( out ) differential See note 2 Sensitivity to DC magnetic field (S) Tolerance of sensitivity (S err ) (@ B ± B LR ) Temperature coefficient of sensitivity 50 /T (5 m/g) < 0.5% of S Differential output; see note 3 100 S'- S / S ; see notes 3 and 4 < ± 100 ppm/ C @ T= 23 C ± 10 C Non-linearity (NL) < 0.1 % @ B ± B LR ; See note 4 Planar Hall voltage ( planar ) (@ B ± B LR ) Long-term instability of sensitivity < 0.01% of normal See note 5 < 1% over 10 years Offset (@ B = 0 T) ( off (B off )) < ± 3 m (± 0.06 mt) @ Temp. range 23 C ± 3 C Temperature coefficient of the offset Offset fluctuation & drift (Δt = 0.05s, t = 100s) Output noise < ± 0.5 m/ C (± 0.01 mt/ C) < 2.0 m p-p (0.04 mt p-p ) Corresponding Standard deviation RMS values are: < 350 µ RMS (7 µt RMS ); see note 6 Noise spectral density @ f = 1Hz (NSD 1 ) Corner frequency (f C ) 100 µ/ Hz (2µT/ Hz ) Region of 1/f-noise 10 Hz Where 1/f-noise = white noise Page 2 / 7

Noise spectral density @ f >10 Hz (NSD w ) Broad-band noise (10 Hz to f T ) ( nrms-b ) 40 µ/ Hz (0.8 µt/ Hz ) Region of white noise < 2.5 m (0.05 mt) RMS noise; see note 7 Resolution See notes 6-10 Typical frequency response 0.1% error > 110 Hz 1.0% error > 350 Hz Test: B 150mT sin(2πft) ; see Frequency Response below Bandwidth [f T ] Output resistance Temperature output > 2.5 khz < 10 Ω, short circuit proof Sensitivity decrease -3dB; see note 11 [T( C)-(23 C ± 0.5 C)] x 500 [m/ C] Single-ended Environmental Parameters: Operating Temperature Storage Temperature Electromagnetic +5 C to +45 C -20 C to +85 C Compliant to standard norms Documentation available upon request. Magnetic Flux Density (B) Units: 1 T = 10 kg; 1 µt = 10 mg Recommended Accessories: Power supply S12-5 [DC output: ±12, +5]; [AC input: ~110/220, 50/60 Hz] (http://www.senis.ch/images/power%20supply%20s12-5%20version%20c_datasheet.pdf) Zero Gauss Chamber: ZG12 (http://www.senis.ch/images/zero%20gauss%20chamber%20zg12.pdf) Output cable 1.5 meter: CO15-G Three-Axis Differential-to-Single ended Adapter 3DSA-05 Probe support: PSB (http://www.senis.ch/images/psb-r04.pdf) Page 3 / 7

DC Calibration The calibration table of the transducer can be ordered as an option. The calibration table is an Excel-file, giving the actual values of the transducer output voltages for the test DC magnetic flux densities measured by a reference NMR Tesla-meter. The standard calibration table covers the linear range of magnetic flux density ± B LR in the steps of B LR /10. Different calibration tables are available upon request. By the utilisation of the calibration table, the accuracy of DC and low-frequency magnetic measurement can be increased up to the limit given by the resolution (see Notes 1 and 6 10). AC Calibration Another option is the calibration table of the frequency response. This is an Excel file, giving the actual values of the transducer transfer function (complex sensitivity and Bode plots) for a reference AC magnetic flux density. The standard frequency response calibration table covers the transducer bandwidth, from DC to f T, in the steps of f T /10. Different calibration tables are also available upon request. Utilisation of the frequency calibration table allows an accuracy increase of the AC magnetic measurements almost up to the limit given by the resolution (see Notes 1 and 6 11). SENIS s 3-axes integrated Hall probe works well in the B-frequency range from DC to 2.5KHz (-3dB point) (B denotes here the density of the measured magnetic flux). In addition to the Hall voltage, at high B frequencies appear also inductive signals generated at the connection probe-thin cable. Moreover, the probe, the cable and the electronics in the E-module behave as a low-pass filter. As a result, the transducer has a "complex" sensitivity of the form: S=S +js h i Here: S h represents sensitivity for the output signal in phase with the magnetic flux density (that is the real part of the transfer function); S i is the sensitivity with the 90 phase shift with respect to the magnetic flux density (i.e., the imaginary part of the transfer function). Calibration data can be ordered for S h and S i for all 3 axes (as an option). This allows the customer to deduce accurate values of the measured magnetic flux density at even high frequencies by an appropriate mathematical treatment of the transducer output voltage out. Page 4 / 7

NOTES: 1) The accuracy of the transducer is defined as the maximum difference between the actual measured magnetic flux density and that given by the transducer. In other words, the term accuracy expresses the maximum measurement error. After zeroing the offset at the nominal temperature, the worst case relative measurement error of the transducer is given by the following expression: Max. Relative Error: M.R.E.=S err +NL+100 Res /BLR [unit: % of B LR ] Eq. [1] Here, S err is the tolerance of the sensitivity (relative error in percents of S), NL is the maximal relative nonlinearity error (see note 4), Res is the absolute resolution (Notes 6-10) and B LR is the linear range of magnetic flux density. 2) The output of the measurement channel has two terminals and the output signal is the (differential) voltage between these two terminals. However, each output terminal can be used also as a single-ended output relative to common signal. In this case the sensitivity is approx. 1/2 of that of the differential output (Remark: The single-ended output is not calibrated). 3) Sensitivity is given as the nominal slope of an ideal linear function out = f(b), i.e. out =S B Eq. [2] where out, S and B represent transducer output voltage, sensitivity and the measured magnetic flux density, respectively. 4) Nonlinearity is the deviation of the function B measured = f (B actual ) from the best linear fit of this function. Usually, the maximum of this deviation is expressed in terms of percentage of the full-scale input. Accordingly, the nonlinearity error is calculated as follows: - out off NL =100 -B /BLR S MAX (for -B LR <B<B LR ) Eq. [3] Notation: B out (B) off Actual testing DC magnetic flux density given by a reference NMR Teslameter Corresponding measured transducer output voltage after zeroing the Offset S Slope of the best linear fit of the function f(b) = out (B) off (i.e. the actual sensitivity) B LR Linear range of magnetic flux density Page 5 / 7

5) The planar Hall voltage is the voltage at the output of a Hall transducer produced by a magnetic flux density vector co-planar with the Hall plate. The planar Hall voltage is approximately proportional to the square of the measured magnetic flux density. Therefore, for example: planar planar =4 normal @ B=0.2T (DC) normal @B=0.1T (DC) Eq. [4] Here, normal denotes the normal Hall voltage, i.e., the transducer output voltage when the magnetic field is perpendicular to the Hall plate. 6) This is the 6-sigma peak-to-peak span of offset fluctuations with sampling time Δt=0.05s and total measurement time t=100s. The measurement conditions correspond to the frequency bandwidth from 0.01Hz to 10Hz. The 6-sigma means that in average 0.27% of the measurement time offset will exceed the given peak-topeak span. The corresponding root mean square (RMS) noise equals 1/6 of Offset fluctuation & drift. 7) Total output RMS noise voltage (of all frequencies) of the transducer. The corresponding peak-to-peak noise is about 6 times the RMS noise. See also Notes 8 and 9. 8) Maximal signal bandwidth of the transducer, determined by a built-in low-pass filter with a cut-off frequency f T. In order to decrease noise or avoid aliasing, the frequency bandwidth may be limited by passing the transducer output signal trough an external filter (see Notes 9 and 10). 9) Resolution of the transducer is the smallest detectable change of the magnetic flux density that can be revealed by the output signal. The resolution is limited by the noise of the transducer and depends on the frequency band of interest. The DC resolution is given by the specification Offset fluctuation & drift (see also Note 6).The worst-case (AC resolution) is given by the specification Broad-band noise (see also Note 7). The resolution of a measurement can be increased by limiting the frequency bandwidth of the transducer. This can be done by passing the transducer output signal trough a hardware filter or by averaging the measured values. (Caution: filtering produces a phase shift, and averaging a time delay!) The RMS noise voltage (i.e. resolution) of the transducer in a frequency band from f L to f H can be estimated as follows: 2 f H 2 nrms-b NSD1f 1Hzln +1.57NSDW fh fl 1/2 Eq. [5] Here NSD 1f is the 1/f noise voltage spectral density (RMS) at f=1hz; NSD w is the RMS white noise voltage spectral density; f L is the low, and f H is the high-frequency limit of the bandwidth of interest; and the numerical factor 1.57 comes under the assumption Page 6 / 7

of using a first-order low-pass filter. For a DC measurement: f L =1/measurement time. The high-frequency limit can not be higher than the cut-off frequency of the built-in filter f T : f H f T. If the low-frequency limit f L is higher than the corner frequency f C, then the first term in Eq. (5) can be neglected; otherwise: if the high-frequency limit f H is lower than the corner frequency f C, than the second term in Eq. (5) can be neglected. The corresponding peak-to-peak noise voltage can be calculated according to the 6-sigma rule, i. e., np-p-b 6 x nrms-b. 10) According to the sampling theorem, the sampling frequency must be at least two times higher than the highest frequency of the measured magnetic signal. Let us denote this signal sampling frequency by f sams. However, in order to obtain the best signal-to-noise ratio, it is useful to allow for over-sampling (this way we avoid aliasing of high-frequency noise). Accordingly, for best resolution, the recommended physical sampling frequency of the transducer output voltage is f samp > 5 x f T (or f samp > 5 x f H ), if an additional low-pass filter is used (see Note 9). The number of samples can be reduced by averaging every N subsequent samples, N f samp / f sams. 11) When measuring fast-changing magnetic fields, one should take into account the transport delay of the Hall signals, small inductive signals generated at the connections Hall probe thin cable, and the filter effect of the electronics in the E- Module. Approximately, the transducer transfer function is similar to that of a firstorder low-pass filter, with the bandwidth from DC to f T. The calibration table of the frequency response is available as an option. Page 7 / 7