Movement joints are essential. Movement profiles are distinguished by function

Similar documents
9.4 Product data sheet

Stainless steel products by Schlüter-Systems

Underlayment. bonded impact sound insulation

EDGE PROFILES FOR FLOOR COVERINGS WALL CORNERS AND EDGE PROFILES

Schlüter -KERDI-SHOWER. System components for floor level showers

Schlüter -TROBA-LEVEL

8.6 Product data sheet

8.1 Product data sheet

12.1 Product data sheet

12.1 Schlüter -KERDI-BOARD

laminated on both sides for effective anchoring in the tile adhesive.

Schlüter -Systems Supplementary Price List Autumn 2018

Creating Living Spaces with Tiles. System solutions from Schlüter-Systems. Your competent partner for interior and exterior solutions

6.1. Schlüter -DITRA 25. Application and Function. Underlayment Uncoupling, waterproofing and vapour pressure equalisation. Product data sheet

12.1 Product data sheet

6.1 Product data sheet

SYSTEM SOLUTION KITS Supplementary price list. Great Britain Effective 1 January 2018

Schlüter -TRENDLINE. Profiles for the world of design. High-quality on trend finishes for tile and stone

6.4 Product data sheet

Schlüter -PROFILES and -SYSTEMS Illustrated price list PS 18. Great Britain Effective 1 January 2018

Installation membrane

Schlüter -DITRA-HEAT-E

Schlüter -DITRA-HEAT-E Under tile and stone heating with Schlüter -DITRA technology Installation Manual

8.7 Product data sheet

8.2 Product data sheet

Technical information CONCRETE / SOLID STONE. Reaction resin mortar, epoxy-acrylate-based with styrene USAGE INSTRUCTIONS

flexible couplings for pipe repair

2D Patterns MODULAR & EASY-TO-INSTALL. turf.design 844 TURF OMG. pat e n t pending

HELLA. Linear slot diffuser. Ordering codes. HELLA - Linear diffuser. Linear Diffusers 1 / 18. Example of the ordering code HELLA B-0-0-AN

Technical Handbook. Schlüter -LIPROTEC.

External Pressure... Thermal Expansion in un-restrained pipeline... The critical (buckling) pressure is calculated as follows:

Strain Gauges and Accessories

The University of Melbourne Engineering Mechanics

series KAT Acoustic air transfer units

KSV. Slot diffusers. Ordering code. Description. Linear diffusers 1 / 16

Introduction...COMB-2 Design Considerations and Examples...COMB-3

CIRCO. Sound-attenuating transfer unit QUICK FACTS

Special edition paper

Cabinets G " integrated in upright Handle strip in side panel Easy solution for shortened doors

flexible couplings for pipe connections

E-Invoice. Total. ibuild,inc. Subtotal. Sales Tax (0.0%) 3000 S Jamiaca Ct Suite 210 Aurora, CO Date 12/2/

The greater the thickness the darker the colour may appear, as less light can transfer through.

Thermal loads on optical glass

A N E X C L U S I V E D E V E L O P M E N T O F T H R E E B E D T E R R A C E D P L U S T H R E E A N D F O U R B E D R O O M D E T A C H E D F A M I

Chapter 4-b Axially Loaded Members

Polyvinyl chloride PVC *

ROMUS FINISHING PROFILES FOR LVT. gerflor.com

Slot diffuser. Type VSD35 2/2.6/B/3. with 35 mm wide slot

Mechanics of Materials Primer

Structural Calculations for Juliet balconies using BALCONY 2 System (Aerofoil) handrail. Our ref: JULB2NB Date of issue: March 2017

ME 243. Mechanics of Solids

Sabah Shawkat Cabinet of Structural Engineering Walls carrying vertical loads should be designed as columns. Basically walls are designed in

BRECCIA / SILVER p.14. BRECCIA / NOIR p.24

S E A L E D F L A T E X P A N S I O N J O I N T T A P E S


Linear diffuser. Description

Residential REFERENCES

zehnder stratos CS CS CS CSW CSW Product Overview Model Code (example)

Entrance exam Master Course

Supplement: Statically Indeterminate Trusses and Frames

1. Introduction. 1.1 Overview of Study:

Krantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems

INTRODUCING HORIZONTAL

Main Catalogue. Edition 23, chapter minirack: Phase-out product!

Nozzle diffuser. Dimensions

Lecture Presentation Chapter 8 Equilibrium and Elasticity

13 PRAIRIE 1A A LOW E R B LOW E R C UPPER D UPPER E UPPER UNIT B UNIT A

IT-AP INFORMATION REGARDING THE CE MARK

Thermal Imaging Survey. Conducted at Nottingham

R I B E L E M E N T S

Section Installation accessories. > UNION Series > TIES Series > FIXO Series > CABLO Series > FASTY Series > RAILDIN Series

3000 Residential 4000 Commercial 5000 Industrial Aluminum Fence Systems Lifetime Limited Warranty

Rigid pavement design

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Multi-cone diffuser. Dimensions

Product ranges HOMAPAL Metal and HOMAPAL Magnetic Boards

Lecture 3. Newton s laws. Forces. Friction

Rodless cylinders Series 1600

s tor bric Compensa Fa

SL27C SL32C. ScreenLine. Technical Catalogue. english. double-glazed unit 27 mm 32 mm

MECHANICAL PROPERTIES OF SOLIDS

Krantz. RL-C2 radial slot outlet. Air distribution systems

1. A pure shear deformation is shown. The volume is unchanged. What is the strain tensor.

STANDARD SAMPLE. Reduced section " Diameter. Diameter. 2" Gauge length. Radius

Air distribution systems. Radial outlet RA-N2...

Positive Signal The most technologically advanced. double coated dichroic filters are used, which transmit

22 Which of the following correctly defines the terms stress, strain and Young modulus? stress strain Young modulus

W e a t h e r S e a l s for Windows and Doors. E x c e l l e n c e i n S h a p e a n d F u n c t i o n

TE 75R RESEARCH RUBBER FRICTION TEST MACHINE

MEE224: Engineering Mechanics Lecture 4

Air distribution systems. Adjustable induction outlet IN-V...

PRESSURE VESSELS & PRESSURE CABINS FOR BLENDED WING BODIES

Simple Building Estimating. Example Reports

Air distribution systems. Jet nozzle DW-N2... Swivel jet nozzle DW-V2... Twist nozzle DW-V2-...-DR

9 MECHANICAL PROPERTIES OF SOLIDS

STATICALLY INDETERMINATE STRUCTURES

3B SCIENTIFIC PHYSICS

N = Shear stress / Shear strain

Regufoam. Vibration 270 Plus.

G-FIRE FLANGE ADAPTERS

Transcription:

Schlüter -DILEX

Movement joints are essential Although at first glance they don t appear to move, tiles, screed, and concrete are living materials. Even massive structures made of these materials are constantly subject to form changes (deformation). Such deformations are caused by drying, loads, changes in moisture content and temperature fluctuations, which can combine and compound one another. To ensure that deformation does not cause damage, screed and covering assemblies e.g., tiled floors, must include movement joints, which allow movement to occur limiting stresses which could cause damage to the covering. The requirements listed in BS 5385 parts 1-5, must be observed. These information documents also include specific recommendations regarding the width and positioning arrangements of the joints. Schlüter -Systems offers the option of producing movement joints with Schlüter -DILEX profiles. In contrast to conventional sealant joints, such joints are permanently maintenance free. They are established in conjunction with the installation of the tiles, eliminating the need for additional installation requirements. This information brochure illustrates the installation of profiles to create movement joints as an alternative to the use of elastic sealants. Movement profiles are distinguished by function Structural joints (expansion joints) are joints required for static or engineering reasons, which divide a building in various movement segments. They run through all load bearing and non load bearing parts of a building and must be continued in the screed construction and the floor covering at the identical location and in the specified width. Intermediate joints create a pattern of limited fields in large areas of screed and covering. They must be continued from the surface of the covering to the separating layer under the screed or to the covering of the insulation or waterproofing layer. In door transition areas, the screed should contain movement joints, which are continued in the covering to reduce stresses occurring at these locations and to prevent the transmission of impact sound. Movement joints in the substrate may not be closed or covered with flooring materials. Perimeter joints are movement joints placed in the screed and the covering along walls and construction elements that penetrate the screed, such as columns. They reduce impact sound transmission and absorb the movements of the floor assembly. Edge joints may not be rigidly closed, since this may lead to the formation of sound bridges and tensions in the covering construction. Our range of movement joints includes cove-shaped profiles for wall/floor transitions and inside wall corners. They are designed to allow for especially easy cleaning. This type of damage is preventable with Schlüter -DILEX movement profiles. Connection joints are movement joints placed in the screed and the covering at construction elements such as window openings, doorframes, shower trays and bath tubs. 2

S T R U C T U R A L J O I N T S Schlüter -DILEX-KSBT is a structural movement profile with edge protection, consisting of side anchoring legs of brass, aluminium, or stainless steel connected to a 20 mm or 30 mm wide movement zone of soft synthetic rubber (check suitability for areas exposed to high point loads, e.g. stilletto heels). Stainless steel: 8-10 - 12.5-14 - 16-18.5-21 - 25-30 mm Brass: 8-10 - 12.5-16 mm Aluminium: 8-10 - 12.5-14 mm Colours*: G - GS - HB Accessories: Stainless steel insert for the movement zone of KSBT 30 Schlüter -DILEX-BT is a structural expansion joint made of aluminium or brass with lateral joint connections to a sliding telescopic centre section. This allows for absorption of three dimensional movement. 11 KSBT 30 / VE KSBT 20 / EL KSBT 30 / EL Aluminium: 8-10 - 12.5-15 - 17.5-20 mm Anodised aluminium: 8-10 - 12.5-15 - 17.5-20 mm I N T E R M E D I A T E J O I N T S DILEX-EKSB Schlüter -DILEX-KS is a movement profile with edge protection consisting of lateral anchoring legs made of brass, aluminium, or stainless steel, which are connected to a replaceable movement zone made of soft rubber. Brass: 8-10 - 12.5-16 mm Stainless steel: 2.5-4.5-6 - 8-10 - 11-12.5-14 - 16-18.5-21 - 25-30 mm Aluminium: 8-10 - 11-12.5-14 mm Colours*: G - GS - HB - PG Schlüter -DILEX-AKWS is a movement profile with side anchoring legs of aluminium connected to a soft PVC movement zone. H = 8-9 - 10-11 - 12.5-14 - 16-21 mm Colours*: G - GS - HB - PG Schlüter -DILEX-EDP is a stainless steel movement profile, which allows horizontal movement through a tongue and groove connection. H = 8-9 - 10-11 - 12.5 14-16 - 18.5-21 - 25-30 mm * see colour swatch on page 8 3

I N T E R M E D I A T E j o i n t s Schlüter -DILEX-BWB is a movement joint profile with side sections of rigid, recycled plastic. The top movement zone is made of soft CPE and creates the 10 mm wide visual surface. H = 6-8 - 10-12.5-15 - 20 mm Colours*: BW - G - GS - HB - PG SP Schlüter -DILEX-BWS is a movement joint profile with side sections of rigid, recycled plastic. The movement zone consists of soft CPE and creates the 5 mm wide visual surface. H = 4.5-6 - 8-9 - 10-11 - 12.5 mm Colours*: BW - G - GS - HB - PG SP Schlüter -DILEX-EP is a movement joint profile for application in floating or bonded screeds. The side sections consist of rigid, recycled plastic connected on the top and bottom with soft, grey CPE movement zones. H = 30-40 - 50 mm Schlüter -DILEX-MOP is an expansion joint profile with serrated side walls made of rigid, recycled PVC and a grey, soft PVC expansion zone for use in screed applications. The profile is able to absorb compression stresses, but not tensile stresses. H = 35-50 - 65 mm Colours*: G Schlüter -DILEX-MP/-MPV is an expansion joint profile with undercut side walls made of rigid, recycled PVC and a soft CPE expansion zone, complete with extension profiles for use in the laying of screeds. The profile is able to absorb compression stresses, but not tensile stresses. Profile height: Schlüter -DILEX-MP 35 mm Extensions: Schlüter -DILEX-MPV 15 and 25 mm Colours*: G - GS - HB - ZR 4 * see colour swatch on page 8

I N T E R M E D I A T E j o i n t s Schlüter -DILEX-EMP is a stainless steel movement profile for screeds. The tongue and groove connections accommodate horizontal movement. Length supplied (=H): H = 35-50 - 65 mm Schlüter -DILEX-EZ 70 is a stress relieving and decorative profile with undercut side walls made of rigid PVC and a soft PVC expansion zone for use in screeds. The extension segments can be removed to adjust the profile height to the height of the assembly. The profile is able to absorb compression stresses, but not tensile stresses. Length supplied (=H): 70 mm Colours: G (grey); M (brass insert); C (chrome insert) Schlüter -DILEX-DFP is a movement joint profile to be installed at door areas or used to divide screed areas. 10 Length: 60-80 - 100 mm = H DFP Schlüter -DILEX-HVD a height offset dowel for installation in the screed, helps prevent height discrepancies between two screed sections in the area of a movement joint. P E R I M E T E R A N D C O R N E R J O I N T S Schlüter -DILEX-RF is a two-part corner profile made of recycled, rigid PVC and soft CPE for durable, flexible, and maintenance free perimeter joints between floors and walls. U = 10-12.5-15 - 18-22 mm O = 8-10 - 12.5-15 - 18 mm Colours*: G - PG * see colour swatch on page 8 5

P E R I M E T E R A N D C O R N E R J O I N T S Schlüter -DILEX-EK is a two-part corner profile made of recycled, rigid PVC and soft CPE for durable, flexible, and maintenance free perime ter joints between floors and walls or floors and skirtings. U = 8-11 - 15 mm O = 7-10 - 14 mm Colours*: BW - G - GS - HB - PG Schlüter -DILEX-EF is a flexible, single piece corner profile of rigid and soft PVC for inside wall corners of floor/wall transitions, which can be used for non-floating covering assemblies. Length supplied (=H): 8-10 - 12.5-15 mm Colours*: BW - G - HB - PG - SP Schlüter -DILEX-EKE is a corner movement profile that effectively absorbs movement at inside wall corners and at floor/wall transitions in applications where no large movement is expected. U 8/ O 7 mm U 9/ O 8 mm U 11/ O 10 mm U 13/ O 12 mm U 15/ O 14 mm Colours*: BW - G - GS - HB - PG - SP Schlüter -DILEX-HKW is a cove shaped profile for internal wall corners and wall/floor joints in applications where only slight movement occurs. U 7/ O 7 mm U 9/ O 9 mm U 11/ O 11 mm Colours*: BW - G - HB - PG Accessories: Inside and outside corners, end caps Schlüter -DILEX-HK is a cove shaped profile for wall/ floor joints, which conforms to the hygienic requirements of commercial bathrooms and the food processing industry. U 12/ O 9 mm, U 18/ O 9 mm Colours*: BW - G - HB Accessories: Inside and outside corners, end caps, and connectors 6 * see colour swatch on page 8

P E R I M E T E R A N D C O R N E R J O I N T S Schlüter -DILEX-HKS is a cove shaped, stainless steel profile with a maintenance free movement zone for floor/wall connections in ceramic tile coverings. Also available in brushed finishes. U = 8-10 - 12-14 - 16-18 - 21-25 - 30 mm O = 7-9 - 11 mm Colours*: G - GS - HB - PG Accessories: Inside and outside corners, connectors Schlüter -DILEX-EHK is a stainless steel, cove shaped profile for internal wall corners or for floor/wall transitions with high hygienic requirements. Also available in brushed finishes. U 7/ O 7 mm U 9/ O 9 mm U 11/ O 11 mm Accessories: Inside and outside corners, connectors Schlüter -DILEX-AHK is a cove shaped aluminium profile for inside wall corners. It is available with a variety of anodised surfaces. Length supplied (=H): 8-10 - 12.5 mm Finishes*: AE, ACG, ACGB, AK, AKG, AKGB, AM, AMG, AMGB, AT, ATG, ATGB C O N N E C T I O N J O I N T S Schlüter -DILEX-KSA is a connection profile with edge protection. The profile s anchoring legs, made of brass, aluminium, or stainless steel, are connected to a replaceable movement zone made of soft PVC. The profile is used for creating transitions between coverings and fixed structures, such as windows. = H Length supplied (=H): Stainless steel: 8-10 - 11-12.5-14 - 16-18.5-21 - 25-30 mm Brass: 8-10 - 12.5-16 mm Aluminium: 8-10 - 11-12.5-14 mm Colours*: G - GS - HB - PG Schlüter -DILEX-BWA provides a flexible connection between tiled surfaces and existing coverings or structures, such as door and window frames. Length supplied (=H): 4.5, 6, 8, 10, 12.5 mm Colours*: BW - G - GS - HB - PG * see colour swatch on page 8 7

C O N N E C T I O N J O I N T S Schlüter -DILEX-AS is a joining profile for creating flexible joints to fixtures such as shower trays, baths, door and window frames. For tile thicknesses 6-12 mm. Colours*: BW - G - HB - PG Accessories: Inside corners and end caps Schlüter -DILEX-EZ 6 + 9 combine decorative design with a stress relieving function for tile and natural stone surfaces laid in a thin bed of adhesive. Length supplied (=H): 6-9 mm Colour combinations**: M/G (brass insert / grey), C/CG (chrome insert / yellow) ** The profiles have two exposed areas that may vary in colour C O L O U R S W A T C H BW brilliant white RAL 9010 GS black RAL 9011 SP soft peach no RAL CG yellow RAL 1021 HB light beige RAL 1019 ZR brick red RAL 8004 G grey RAL 7030 PG pastel grey no RAL A N O D I S E D F I N I S H E S AE = anodised alu. ACG = polished chrome anodised alu. ACGB = brushed chrome anodised alu. 8 AK = satin copper/bronze anodised alu. AKG = polished copper/bronze anodised alu. AKGB = brushed copper/bronze anodised alu. AM = satin brass anodised alu. AMG = polished brass anodised alu. AMGB = brushed brass anodised alu. AT = satin titanium anodised alu. ATG = polished titanium anodised alu. ATGB = brushed titanium anodised alu. Schlüter-Systems KG Schmölestraße 7 D-58640 Iserlohn Tel. 00 49 / 23 71 / 971-261 Fax 00 49 / 23 71 / 971-112 Internet www.schlueter-systems.com Schlüter-Systems Ltd Units 4 6 Bardon 22 Beveridge Lane COALVILLE Leicestershire LE67 1TE Tel. 00 44 (0) 1530 813396 Fax. 00 44 (0) 1530 813376 Internet www.schluter.co.uk Email technical@schluter.co.uk sales@schluter.co.uk Art.-No. 551 898 - Issue 04/10