A sodium (Na) beam edge diagnostic

Similar documents
The current status of the Lithium beam diagnostic at ASDEX Upgrade

Cesium Dynamics and H - Density in the Extended Boundary Layer of Negative Hydrogen Ion Sources for Fusion

Diagnostic Lithium Beam System for COMPASS Tokamak

Estimating the plasma flow in a recombining plasma from

Recent Developments and Applications of Bayesian Data Analysis in Fusion Science: Integrated Data Analysis

New Detection System for Fast Density Measurements Using the Lithium Beam on the COMPASS Tokamak

Plasma Spectroscopy in ISTTOK

Characteristics of the H-mode H and Extrapolation to ITER

Introduction to Integrated Data Analysis

Development of a Lithium Beam Probe and Measurement of Density Pedestal in JT-60U

Integrated Bayesian Experimental Design

Spatio-temporal investigations on the triggering of pellet induced ELMs

Temporal Evolution of Temperature and Argon Impurity Density Profiles Observed by X-ray Imaging Spectrometer Measurements at Wendelstein 7-X

EFFECT OF EDGE NEUTRAL SOUCE PROFILE ON H-MODE PEDESTAL HEIGHT AND ELM SIZE

Impurity Seeding in ASDEX Upgrade Tokamak Modeled by COREDIV Code

Blob sizes and velocities in the Alcator C-Mod scrapeoff

UPGRADED CALIBRATIONS OF THE THOMSON SYSTEM AT DIII D

Erosion and Confinement of Tungsten in ASDEX Upgrade

Evolution of the pedestal on MAST and the implications for ELM power loadings

Direct measurements of the plasma potential in ELMy H mode. plasma with ball pen probes on ASDEX Upgrade tokamak

Effect ofe B driven transport on the deposition of carbon in the outer divertor of ASDEX Upgrade

Aspects and prospects of

1 EX/P6-5 Analysis of Pedestal Characteristics in JT-60U H-mode Plasmas Based on Monte-Carlo Neutral Transport Simulation

Radiative type-iii ELMy H-mode in all-tungsten ASDEX Upgrade

Correlations of ELM frequency with pedestal plasma characteristics

LITHIUM DIAGNOSTIC BEAM DEVELOPMENT FOR FUSION PLASMA MEASUREMENTS PhD thesis GÁBOR ANDA. Thesis Supervisor: DR. SÁNDOR ZOLETNIK MTA KFKI RMKI

Divertor power deposition and target current asymmetries during type-i ELMs in ASDEX Upgrade and JET

The role of stochastization in fast MHD phenomena on ASDEX Upgrade

Confinement and edge studies towards low ρ* and ν* at JET

L-Mode and Inter-ELM Divertor Particle and Heat Flux Width Scaling on MAST

Progress in characterization of the H-mode pedestal

Mitigation of ELMs and Disruptions by Pellet Injection

Scaling of divertor heat flux profile widths in DIII-D

Plasma Radiation. Ø Free electrons Blackbody emission Bremsstrahlung

Progress of Confinement Physics Study in Compact Helical System

Thomson Scattering with laser intra-cavity multipass system to study fast changing structures in fusion plasma

Power Balance Analysis of Wendelstein 7-X Plasmas Using Profile Diagnostics

Improved EDGE2D-EIRENE Simulations of JET ITER-like Wall L-mode Discharges Utilising Poloidal VUV/visible Spectral Emission Profiles

II: The role of hydrogen chemistry in present experiments and in ITER edge plasmas. D. Reiter

Max-Planck-Institut für Plasmaphysik, EURATOM Association POB 1533, D Garching, Germany

Scaling of divertor heat flux profile widths in DIII-D

Study of Current drive efficiency and its correlation with photon temperature in the HT-7 tokomak

Power Deposition Measurements in Deuterium and Helium Discharges in JET MKIIGB Divertor by IR-Thermography

Power Balance and Scaling of the Radiated Power in the Divertor and Main Plasma of Alcator C-Mod

Impurity accumulation in the main plasma and radiation processes in the divetor plasma of JT-60U

Flow measurements in the Scrape-Off Layer of Alcator C-Mod using Impurity Plumes

Study of B +1, B +4 and B +5 impurity poloidal rotation in Alcator C-Mod plasmas for 0.75 ρ 1.0.

Electron temperature barriers in the RFX-mod experiment

Radial impurity transport in the H mode transport barrier region in Alcator C-Mod

Performance, Heating, and Current Drive Scenarios of ASDEX Upgrade Advanced Tokamak Discharges

Noninductive Formation of Spherical Tokamak at 7 Times the Plasma Cutoff Density by Electron Bernstein Wave Heating and Current Drive on LATE

GA A22722 CENTRAL THOMSON SCATTERING UPGRADE ON DIII D

VII. Publication VII IOP Publishing Ltd. By permission.

Local Plasma Parameters and H-Mode Threshold in Alcator C-Mod

Magnetic Flux Surface Measurements at Wendelstein 7-X

In situ wavelength calibration of the edge CXS spectrometers on JET

Bolometry. H. Kroegler Assciazione Euratom-ENEA sulla Fusione, Frascati (Italy)

Impact of Localized ECRH on NBI and ICRH Driven Alfven Eigenmodes in the ASDEX Upgrade Tokamak

Electron Bernstein Wave Heating in the TCV Tokamak

Evaluation of Anomalous Fast-Ion Losses in Alcator C-Mod

Simulation of ASDEX Upgrade Ohmic Plasmas for SOLPS Code Validation

Quantification of the contribution of processes in the ADAS beam model

Erosion and Confinement of Tungsten in ASDEX Upgrade

Edge Zonal Flows and Blob Propagation in Alcator C-Mod P5.073 EPS 2011

2D ECE measurements of type-i Edge Localized Modes at ASDEX Upgrade

Beam-plasma atomic data needs for fusion devices

Alcator C-Mod. Double Transport Barrier Plasmas. in Alcator C-Mod. J.E. Rice for the C-Mod Group. MIT PSFC, Cambridge, MA 02139

Impurity Transport Studies of Intrinsic MO and Injected Ge in High Temperature ECRH Heated FTU Tokamak Plasmas

Measurements of rotational transform due to noninductive toroidal current using motional Stark effect spectroscopy in the Large Helical Device

Heating and Confinement Study of Globus-M Low Aspect Ratio Plasma

First Observation of ELM Suppression by Magnetic Perturbations in ASDEX Upgrade and Comparison to DIII-D Matched-Shape Plasmas

3D analysis of impurity transport and radiation for ITER limiter start-up configurations

Development of a High-Speed VUV Camera System for 2-Dimensional Imaging of Edge Turbulent Structure in the LHD

On Lithium Wall and Performance of Magnetic Fusion Device

Physical Performance Analysis And The Progress Of The Development Of The Negative Ion RF Source For The ITER NBI System

GA A26123 PARTICLE, HEAT, AND SHEATH POWER TRANSMISSION FACTOR PROFILES DURING ELM SUPPRESSION EXPERIMENTS ON DIII-D

Development and Validation of a Predictive Model for the Pedestal Height (EPED1)

Application of the ECRH radiation for plasma diagnostics in Wendelstein 7-X

Beam Species Characteristics of High Current Ion Source for EAST Neutral Beam Injector

Diagnostic Capabilities of Line-Integrated Neutron Pulse Height Spectra Measurements

Impact of Neon Injection on Electron Density Peaking in JET Hybrid Plasmas

SUMMARY OF EXPERIMENTAL CORE TURBULENCE CHARACTERISTICS IN OH AND ECRH T-10 TOKAMAK PLASMAS

L-mode radiative plasma edge studies for model validation in ASDEX Upgrade and JET

Extension of Wavelength Range in Absolute Intensity Calibration of Space-Resolved EUV Spectrometer for LHD Diagnostics )

Partially Coherent Fluctuations in Novel High Confinement Regimes of a Tokamak

The effect of the radial electric field on neoclassical flows in a tokamak pedestal

NIST Research on Spectroscopy and Collisional-Radiative Modeling of Highly-Charged Ions of Tungsten

Introduction to the Diagnosis of Magnetically Confined Thermonuclear Plasma

Pedestals and Fluctuations in C-Mod Enhanced D α H-modes

Improved Plasma Confinement by Ion Bernstein Waves (IBWs) Interacting with Ions in JET (Joint European Torus)

GA A22443 STUDY OF H MODE THRESHOLD CONDITIONS IN DIII D

Edge Momentum Transport by Neutrals

Connections between Particle Transport and Turbulence Structures in the Edge and SOL of Alcator C-Mod

Impurity expulsion in an RFP plasma and the role of temperature screening

PFC/JA MEASUREMENT OF THE D-D FUSION NEUTRON ENERGY SPECTRUM AND VARIATION OF THE PEAK WIDTH WITH PLASMA ION TEMPERATURE

Fast ion physics in the C-2U advanced, beam-driven FRC

Alcator C-Mod. Particle Transport in the Scrape-off Layer and Relationship to Discharge Density Limit in Alcator C-Mod

Divertor Requirements and Performance in ITER

Nuclear Fusion Energy Research at AUB Ghassan Antar. Physics Department American University of Beirut

Triggering Mechanisms for Transport Barriers

Transcription:

P2-39 A sodium (Na) beam edge diagnostic E.Wolfrum a*, J. Schweinzer a, D. Bridi b, K. Igenbergs b, J. Kamleitner b, F. Aumayr b and the ASDEX Upgrade Team a a Max Planck Institut für Plasmaphysik, EURATOM Association, Garching, Germany b Institut für Allgemeine Physik, TU Wien, EURATOM Association ÖAW, Vienna, Austria Abstract A fast (40-80 kev) neutral sodium (Na) beam is considered as advantageous alternative to the fast lithium (Li) beam installed at ASDEX Upgrade. Recently, a complete data set of all relevant plasma particles (electron, ions) Na collisions has been compiled [1] and first experiments with a Na beam installed at ASDEX Upgrade have been carried out. A collisional radiative model is employed to calculate the beam attenuation in a plasma discharge as well as the occupation number of Na excited states (including n=3, 4 & 5s). Excellent agreement between modeled and measured Na I emission profiles is found, proving the validity of the compiled data set. Despite the lower velocity at the same acceleration voltage, beam penetration of Na as compared with Li is not significantly deteriorated. The influence of electron temperature (T e ) and Z eff profiles on evaluated electron density (n e ) profiles is analyzed. JNM Keywords: PSI 18 Keywords: PACS: Corresponding author: Presenting author: E0500, P0600 ASDEX-Upgrade, Collisional-radiative model, Edge plasma, Lithium beam 52.40.Mj, 52.55.Fa, 52.70.Kz E. Wolfrum, MPI f. Plasmaphysik Boltzmannstraße 2, D-85748 Garching e.wolfrum@ipp.mpg.de F. Aumayr, Institut f. Allgemeine Physik, TU Wien Wiedner Hauptstr. 8-10/134, A-1040 Wien aumayr@iap.tuwien.ac.at 1

I Introduction Steep density and temperature gradients characterize the edge plasma of tokamaks in the H-mode (high confinement mode). Within a few centimeters n e rises one order of magnitude, T e can even increase by two orders of magnitude. At ASDEX Upgrade the measurements in this region are provided by a number of different diagnostics, which are located at different places around the torus [2]. The 40-50 kev lithium beam diagnostic at ASDEX Upgrade [3,4,5] delivers routinely n e profiles and for selected discharges T i and n i profiles. A novel probabilistic evaluation algorithm involving Bayesian statistics [6] allows the determination of the pedestal top densities up to n e of 7 10 19 m -3. In order to improve this diagnostic further the lithium emitter can be replaced by a sodium (Na) emitter. There are several advantages of a Na emitter when compared to Li: i) the emitter temperature can be kept lower, thus improving the withstand voltage and the stability of the ion source at higher voltages (>60 kv), ii) the charge exchange cross sections for collisions with relevant impurity ions (He, C) are larger, facilitating ion temperature measurements, iii) the lifetime of the observed transition (Na I (3p-3s)) is with 16.2 ns shorter than the Li I (2p-2s) with 26.9 ns, which is of benefit to the planned density fluctuation measurements [7]. iv) The neutralization of the ion beam occurs in a Na cell. As the charge exchange cross section between Na + and Na 0 is higher than between Li+ and Na 0, a high neutralization efficiency is achieved at lower densities in the charge exchange cell. v) The observed transition (Na I (3p-3s)) emits photons at a wavelength of 588.9 nm. The used photomultipliers have a higher sensitivity in the yellow region than in the red (Li I @ 670.8 nm), leading again to a signal-to-noise ratio improvement. 2

The only disadvantages of Na when compared to Li are the higher atomic mass and the slightly smaller ionization energy, raising the question whether Na atoms will penetrate as far as Li into the plasma and provide n e data at the pedestal top. II Modeling The beam attenuation modeling takes into account all collisions of the neutral beam atoms with plasma particles, including electron and proton impact excitation, ionization and charge exchange processes. The spatial occupation number densities N i of atomic states i (Li: 10 states: 2s, 2p,, 4f and Li + ; Na: 9 states: 3s, 3p,, 5s and Na + ) are described by a system of coupled linear differential equations: (1) z is the coordinate along the injected lithium beam, the coefficients a ij contain the population and depopulation rate coefficients from level i-> j due to collisions with electrons, protons and impurity ions, the coefficients b ij are the Einstein coefficients for the radiative transitions. The rate coefficients a ij are calculated using the database described in [1], where all relevant cross sections are given in the form of a recommended fit to theoretical as well as experimental data. Below a beam energy of 20 kev the fits are not valid any longer, because the relative collision velocities become too small. In the following we will show modeled Na I emission profiles for four density profiles with varying pedestal top density values. We chose single time spans out of typical discharge scenarios, such as the standard ohmic and the standard H-mode shot of ASDEX Upgrade, as well as two discharges where both, the Na I and the Li I emission profile could be measured (see sections III and IV). 3

In figure 1 the n e (1a) and T e (1b) profiles for the four different discharges are plotted. The data shown are fits to experimentally determined values (density: Lithium beam diagnostic and edge Thomson scattering diagnostic, temperature: ECE diagnostic and edge Thomson scattering diagnostic) mapped to the magnetic midplane. For details of n e and T e pedestal top values as well as position of the separatrix see table 1. Figure 2 displays the modeled emission profiles: (2a) for a Li beam at 40 kev and (2b) for a Na beam at 40 and 80 kev. The profiles shown in figure 1 are used as input for modeling. The most striking observation is that the maxima of the Na I emission profiles are only slightly shifted to the outside. Also, the difference between a 40 kev and 80 kev Na beam is only marginal. This is mainly due to the fact that the excited states of Na are considerably less occupied than in the case of Li and consequently the very efficient charge exchange from these states, contributing to the attenuation of the beam, plays a minor role. The penetration depth of a Na beam is thus only slightly shorter than a Li beam at an acceleration voltage of 40 kev. For higher acceleration voltages, the penetration depth of Li increases considerably, while the one of Na hardly changes. The evaluation of n e relies on the inversion of the second equation of (eqn. 1) applying a shooting method [8] and is numerically very sensitive to a singularity condition at a certain z value (, i.e. population equals depopulation of the Li(2p)/Na(3p) state by collisions). Due to less populated excited states in the case of Na, the position of the singularity is shifted to larger z with respect to the maximum of the emission profile. Table 1 also lists the penetration depths, i.e. where the ground state is attenuated to 5%, and the positions of the singularity for the case of 40 kev Li and 40 and 80 kev Na beams for the four chosen discharge scenarios. While the Li beam penetrates deeper 4

into the plasma, the position of the singularity and thus the point up to which an evaluation of n e is possible is similar for both species. A detailed comparison of electron densities and their uncertainties derived from the novel probabilistic evaluation algorithm [6], where the singularity is irrelevant, is part of future work. Temperature dependence During routine plasma operation T e profiles are not immediately available. Therefore a typical T e profile is taken as input for n e evaluation. Such a profile is described by a tanh-shaped curve typical for the edge transport barrier (ETB) zone. At the separatrix position T e is set to 100 ev [9]. T e values in the SOL are usually not well determined and can range from 5 20 ev. The width of the pedestal, i.e. the width of the tanhshaped curve from the top to the bottom values changes with discharge type (L-mode, H-mode) as well as with heating power. The dependence of the evaluated n e profiles on the uncertainty in the assumed T e was tested in two separate steps: i) the profile shape was kept constant for ρ pol < 1 and for ρ pol > 1 the SOL temperatures (T SOL e ) were set to fixed values of 2, 5, 10, 20 and 50 ev (see fig. 3a). The reconstructed n e did not show any effect of these T SOL e changes for ρ pol < 1 (as shown in fig. 3b). For ρ pol > 1 the most significant difference occurred for a T SOL e of 2 ev, which is below the excitation threshold of the 3p-3s transition. For all other settings the calculated n e profiles did not differ by more than 25 % (see fig. 3c, where quotient to the reference profile is shown). SOL ii) The width of the Te profiles was varied between 10 and 80 mm while keeping T e = 5 ev, T sep e = 100 ev and T ped e = 800 ev. Also here the reconstructed n e were not affected significantly. As the evaluated n e profiles are not sensitive to the chosen T e profile, two typical T e profiles were selected, one for H-mode and one for L-mode 5

plasmas. The appropriate profile is selected by a regime identification algorithm and subsequently used for n e determination. Z eff dependence So far modeling was presented for clean D plasmas. Reduced excitation and ionization rates <σv>/v beam, where <. > denotes averaging over the Maxwell distribution, for collisions of Na with plasma electrons and protons were used. Due to the heavier mass of impurity ions, the collision velocity can be approximated by the Na beam energy. The reduced rates <σv>/v beam are simply replaced by the cross sections σ(v beam ), which are easily derived from cross sections for Na atoms colliding with protons and He 2+ via scaling relations [1]. The density of impurity ions can be described by only two parameters, Z eff and q, that can vary for different ρ pol. q is the mean charge of the impurity ions and the effective charge Z eff is defined as, where n i denotes the ion density. Out of both values the fraction of ions with respect to electrons in the plasma is calculated ( ). A pure helium plasma corresponds to Z eff =2, q=2, the fraction becomes 0.5. Figure 4 shows, that Na I emission for a helium plasma is lower than for D plasma. The backward calculated n e -profiles are the same. Figure 4 also shows what happens, if a false Z eff profile is used. If the calculation is done for He plasma, but the emission profile is measured in a D plasma, the calculated n e is too low. If the calculation is done for D plasma, but the emission profile is measured in a He plasma, the inverted effect occurs, the calculated n e is too high. For 6

these completely false Z eff profiles the differences in n e are about 15%, and for reasonably realistic Z eff profiles these errors remain below 5%. III Experiment In order to test the viability of a Na beam for n e measurements without compromising the routine operation of the Li beam, a combined Na/Li emitter was produced. To the β- eucryptite powder (LiAlSiO 4 ), which is normally used for our Li emitters, NaAlSiO 4 was added in a ratio Li:Na = 9:1. The powder was applied on top of the heating element and slowly heated to ~ 1300 ºC, resulting in a ceramic surface after cooling. Ten such layers were applied consecutively. The experimental setup of the Lithium beam diagnostic at ASDEX Upgrade is shown in [5, Fig. 1]. The optical head at the top of the vessel is equipped with 35 optical fibers, guiding the light to filter-photomultiplier detectors, where the Li I emission is recorded. An other optical head at the bottom is equipped with two rows of 30 fibers each, guiding the light to a switch board, where 18 lines of sight can be selected and analyzed with two Czerny Turner spectrometers, both connected to frame transfer CCD cameras. The spectra are recorded with a frame rate of 4 ms. The acceleration voltage for the Li/Na emitter was set to 40 kev. The beam optics does not contain any mass separation, so both species were well focused. The beam was neutralized in a charge exchange cell filled with Na vapor. During the first few discharges, the emitter temperature was kept lower than usually, at around 900 ºC, and a pure Na beam was produced. When the Na started to be depleted in the ceramic, resulting in a lower beam emission signal, the temperature was raised and in a few 7

discharges both the Li I line as well as the Na I line could be measured, allowing a comparison of the evaluated densities from both signals. After the positive results (see section IV) of the combined emitter test, filters were purchased (FWHM=1.5nm), a Li/Na emitter with Li:Na = 1:9 produced and emission profiles with high spatial and temporal resolution were acquired using the filter-pmsetup. IV Results Emitter Li:Na=9:1 For some discharges Na I and Li I emission profiles were simultaneously measured. The Li I emission profile is measured by the upper optic and gives a reference electron density (n ref e ). For n ref e the Na I emission is calculated and then compared with the Na I emission profile measured by the lower optics. Figure 5 shows the normalized emission profiles modeled with n ref e as input in comparison with the normalized measured profile. The excellent agreement of the two profiles proves the validity of the underlying atomic database. In figure 6 the reconstructed n e profiles from both the measured and the modeled profiles (as shown in fig. 5) are compared to n ref e. Within the ETB zone the n e profiles are very similar. Emitter Li:Na=1:9 8

In the second, dedicated Na experiment, where the Na I emission was recorded with high spatial and temporal resolution, n e profiles were reconstructed on all plasma discharges of two experimental days. As example figure 7 shows the n e profiles derived from the Na beam in comparison with profiles from the edge Thomson scattering diagnostic [10]. The gradient in the ETB zone is well resolved up to the top of the pedestal. Conclusions In dedicated combined Li/Na emitter experiments it was shown that the atomic database [1] is valid. The lower lifetime of the Na 3p state leads to a lower occupation number density of this state and results in a larger than expected penetration depth of the Na beam, so that its accessible radial range is comparable to Li at the same acceleration voltages. The Li beam was successfully replaced by a Na beam for two experimental days. The resulting n e profiles from Na I emission profiles were of comparable quality as the usual ones from Li I emission. A more detailed evaluation of the measured data on these two days is still ongoing. In the near future experiments are planned with a pure Na emitter with the aim of a) exploring the potential of the higher charge exchange cross sections of Na with e.g. He 2+ or C 6+ and b) utilizing the shorter lifetime of the Na 3p state for n e fluctuation measurements with higher spatial resolution. Acknowledgements 9

This work, supported by the European Communities under the Contract of Association between EURATOM and the Austrian Academy of Sciences, was carried out within the framework of the European Fusion Development Agreement. The views and opinions expressed herein do not necessarily reflect those of the European Commission. The mobility programme of the EC has supported participation of J.K. in experiments at IPP Garching. References: [1] K. Igenbergs et al., At. Data Nucl. Data Tables in print. [2] L. Horton et al., Nucl. Fus. 45 (2005) 856 [3] R. Brandenburg et al., Fusion Techn. 36 (1999) 289-295 [4] M. Reich et al., Plasma Phys. Control. Fusion 46 (2004) 797 [5] E.Wolfrum et al., Rev. Sci. Instr. 77 (2006) 033507 [6] R. Fischer et al., accepted by PPCF [7] S. Zoletnik et al., Phys. Plasmas 6 (1999) 4239 [8] J. Schweinzer et al., Plama Phys. Control. Fusion 34 (1992) 1173-1183 [9] J. Neuhauser et al., PPCF 44 (2002) 855 [10] B. Kurzan et al., Rev. Sci. Instr. 72 (2001) 1111 10

Figure Captions: Fig. 1: (a) n e and (b) T e profiles for discharges #20160 (green), #21241 (red), #21990 (black), #21991 (blue) vs. midplane radius. Fig. 2: (a) Li 2p (E beam =40keV) and (b) Na 3p (E beam =40keV, E beam =80keV dotted) occupation profiles vs. beam coordinate modeled for n e and T e profiles of fig. 1 Fig. 3: #21991: (a) T e profile, varying T e SOL, (b) n e calc compared to n e ref (black), (c) ratio to n e ref Fig. 4: #21241: left axis: n e ref (black) compared to reconstructed n e profiles: the first index gives the species for the modeled Na 3p profile, the second for the assumption of the reconstruction: D/D (yellow dots), He/He (blue stars), D/He (red triangles), He/D (green triangles); right axis: Na 3p occupation number for D (yellow line) and He (blue line) Fig. 5: #21990: modeled emission profile (black) and measured data (blue) Fig. 6: #21990: n e ref (black), n e calculated of Na I measured (blue stars), n e calculated of Na I modeled (red dots) Fig. 7: n e profiles determined by Na beam diagnostic (green) and Edge Thomson scattering (pink) 11

Tables: # n e ped=0.95 T e ped=0.95 R sep ρ Li 40kV sing. ρ Na 40kV sing. ρ Na 80kV sing. 10 19 m -3 ev m ρ pol ρ pol ρ pol ρ pol ρ pol ρ pol 20160 6.59 400 2.156 0.95 1.00 0.97 0.97 0.96 0.98 21241 2.24 220 2.145 0.80-0.85-0.83-21990 5.16 280 2.138 0.92 0.99 0.95-0.94 0.96 21991 6.70 550 2.14 0.94 0.99 0.96 0.98 0.95 0.99 Table 1: For the selected n e profiles: shot number (#), pedestal top electron density (n e ped ) and temperature (T e ped ), position of the separatrix (R sep ), for 40 kev Li and 40 kev as well as 80 kev Na: penetration depth (ρ) and point of singularity (sing.) in normalized poloidal radius (ρ pol ). 12

Fig. 1 13

Fig. 2 14

Fig. 3 15

Fig. 4 16

Fig. 5 17

Fig. 6 18

Fig. 7 19