Hints for Strong Ion Exchange Resins

Similar documents
RediSep Rf C18 Flash Column Loading Techniques

Flash chromatography purification of high pka organic compounds with Teledyne Isco s specialty RediSep columns

1. Ion exchange chromatography

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Strategies for the Flash Purification of Highly Polar Compounds

Optimized Flash Chromatography Purification: From TLC to large scale in three steps

Purine and Related Compound

Shodex TM ODP2 HP series columns

ProPac WCX-10 Columns

Strategies to Purify Carbohydrate Based Compounds

Properties of Compounds

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Chromatographic Methods of Analysis Section - 4 : Ion Exchange Chrom. Prof. Tarek A. Fayed

Multi-Prep and Detectabuse Columns and 96 Well Deep-Well Plates for Sample Preparation

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Multistep Synthesis of 5-isopropyl-1,3-cyclohexanedione

Solid Phase Extraction Method Development Tips and Tricks

High Performance Liquid Chromatography

Acclaim Mixed-Mode WCX-1

Ion Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods

I. Properties of Aqueous Solutions A) Electrolytes and Non-Electrolytes B) Predicting Solubility* II. Reactions of Ionic Compounds in Solution*

Chapter 23 Introduction to Analytical Separations

CHEMICAL REACTIONS. There are three ways we write chemical equations. 1. Molecular Equations 2. Full Ionic Equations 3. Net Ionic Equations

Chromatography. What is Chromatography?

Liquid Chromatography

Chapter 7 Solution Chemistry. 7.1 The Nature of Solutions. Warm Up (p. 364) and Quick Check (p. 365)

Ion Chromatography (IC)

Chromatography. Gas Chromatography

The Theory of HPLC. Normal Phase (Absorption) Chromatography

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Chemical synthesis (see also reaction scheme, bold underlined numbers in this text refer to the bold underlined numbers in the scheme)

Method Development with ZirChrom's Ion Exchange Phases

for Acclaim Mixed-Mode HILIC-1 Column

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

Unit 15 Solutions and Molarity

The Theory of HPLC. Ion Pair Chromatography

Chapter 4: Types of Chemical Reactions and Solution Stoichiometry

10.1 Acids and Bases in Aqueous Solution

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Properties of Aqueous Solutions

LC and LC/MS Column Selection Flow Chart

penta-hilic UHPLC COLUMNS

FAQ's. 1 - Which column would be the most appropriate for my application?

Section 4: Aqueous Reactions

for Acclaim Trinity TM P1

penta-hilic UHPLC COLUMNS

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Instrumental Chemical Analysis

Lab 3: Solubility of Organic Compounds

Quick Review. - Chemical equations - Types of chemical reactions - Balancing chemical equations - Stoichiometry - Limiting reactant/reagent

Acclaim Mixed-Mode WAX-1 Columns

Brass, a solid solution of Zn and Cu, is used to make musical instruments and many other objects.

Chapter 4 Reactions in Aqueous Solution

Find the ph and the degree of ionization for an 0.10 M solution of formic acid:

Experiment 1: Thin Layer Chromatography

Name Date. 9. Which substance shows the least change in solubility (grams of solute) from 0 C to 100 C?

Supplementary Note 1 : Chemical synthesis of (E/Z)-4,8-dimethylnona-2,7-dien-4-ol (4)

Stoichiometry: Chemical Calculations. Chemistry is concerned with the properties and the interchange of matter by reaction i.e. structure and change.

Chapter 9: Solutions

8. Methods in Developing Mobile Phase Condition for C18 Column

ACP Chemistry (821) - Mid-Year Review

Experiment 1: Extraction and Thin Layer Chromatography

for Acclaim Mixed-Mode WCX-1

Cation Exchange HPLC Columns

Comparison of different aqueous mobile phase HPLC techniques

19.3 Strengths of Acids and Bases > Chapter 19 Acids, Bases, and Salts Strengths of Acids and Bases

CH 221 Chapter Four Part II Concept Guide

4. Ion chromatography (IC) 4.1. Educational aims and objectives

Chapter 16: Acids and Bases

Chem 103 Exam #1. Identify the letter of the choice that best completes the statement or answers the question. Multiple Choice

Chapter 6. Acids, Bases, and Acid-Base Reactions

Reversed Phase Solvents

MC 17 C SECTION - I (40 marks) Compulsory : Attempt all questions from this section.

Development for SPE. Ron Majors Senior Chemist, CSD Joan Stevens SPE Application Chemist October 2009

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

Chapter 4. Aqueous Reactions and Solution Stoichiometry

PHYSICAL CONSTANTS: MELTING POINTS, BOILING POINTS, DENSITY

Determination of trace anions in concentrated hydrofluoric acid

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Acid Base Equilibria

(Label the Conjugate Pairs) Water in the last example acted as a Bronsted-Lowry base, and here it is acting as an acid. or

Open Column Chromatography, GC, TLC, and HPLC

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

SI session Grue 207A

Acids and bases, as we use them in the lab, are usually aqueous solutions. Ex: when we talk about hydrochloric acid, it is actually hydrogen chloride

Chapter 14. Objectives

Aqueous Reactions and Solution Stoichiometry (continuation)

Stoichiometry: Chemical Calculations. Chapter 3-4

High Performance Liquid Chromatography

High Performance Liquid Chromatography

HPLC solvents and mobile phase additives

Covalent (sharing of electron pairs) Ionic ( electrostatic attraction between oppositely charged ions)

SPE. Simply Efficient! Watchers bond Solid Phase Extraction by ISU. Ver

Adsorption at the solid/liquid interface

Background on Solubility

Methods of purification

What type of samples are common? Time spent on different operations during LC analyses. Number of samples? Aims. Sources of error. Sample preparation

Ondansetron Hydrochloride Tablets

Transcription:

Hints for Strong Ion Exchange Resins Chromatography Application Note AN98 Abstract Ion exchange columns are a powerful means of isolating and purifying compounds, but their use is limited due to lack of a general procedure for using these columns. This application note provides hints that allow purification of compounds without prior knowledge of their pka or ionic strength. Additionally, this application note covers the use of RediSep Strong Anion ion exchange (SAX) and Strong Cation exchange (SCX) columns. Background The term strong ion exchange refers to the functional group on the silica, which may be strongly acidic or basic. The RediSep Rf SAX column possesses a strongly basic tertiary methyl amine group. The RediSep Rf SCX column uses a strongly acidic sulfonic acid group. The SAX column exchanges anions while the SCX column exchanges cations. General Hints Column conditioning The column should be conditioned so that the weakest ion possible is on the column. This makes it easier for the desired compound to displace the ion from the column. For RediSep Rf SCX columns, the ionic strength is: Li<H<NH 4 <Mg<Ca<Fe<Cu<Pb<Ag<Ba For most small molecules, putting the SCX column into the hydrogen form is sufficient to allow binding. Washing the SCX column with 1 column volumes (CV) of.1 N acid (sulfuric or phosphoric preferred) followed by 1 column volumes of water will convert the column to the hydrogen form. For RediSep Rf SAX columns, ionic strength follows the order: F<OH<actate<fomate<Cl<Br<CO 3 <PO 4 <citrate<tosylate For general usage, the column should be put into the acetate form prior to use by washing with 2 column volumes of 5% acetic acid. Note The RediSep Rf SAX column is shipped with the chloride counter-ion, and so requires conversion to the acetate ion. Running the column in the chloride form may cause the desired compound to bind poorly (Figure 1). 1.7 1.6 1.4 1.3 1.1 1..9.8.7.6.5.4.3.2.1. 1.7 1.6 1.4 1.3 1.1 1..9.8.7.6.5.4.3.2.1. 5 1 15 2 25 5 1 15 2 25 Figure 1: Chromatogram of catechin elution. The top column was run as delivered with chloride ion, while the bottom column was conditioned with acetate ion, demonstrating that columns should be conditioned with weak ions prior to use. Sample Preparation Samples need to be ionized prior to injection; for basic compounds, dissolving them in 5% solution acetic acid works well while 5% ammonium hydroxide ionizes acidic compounds. The sample should be dissolved in a minimum volume of water. Column Storage The columns should be conditioned as described under the column conditioning section for future experiments. After conditioning, the columns should be washed and stored in 2-propanol. This solvent is miscible with most other solvents, and prevents the column body from swelling. 1 8 6 4 2 1 8 6 4 2

SCX Examples Suggested gradient 2 1 2 4 6 Figure 2: Alkaloids captured and released with multiple gradient; shaded area denotes peak collection window For the run in Figure 2,.5 g green tea methanolic extract was dissolved in methanol containing 5% acetic acid and loaded onto a 15 g RediSep Rf SCX column (PN 69-223-391). The column was washed with methanol and the compounds eluted with a gradient (5% acetic acid in water) followed by a basic gradient (5% ammonium hydroxide in water). Weak bases, such as xanthine alkaloids, are displaced by hydrogen ions. Stronger bases are eluted with the ammonium ion. The basic ammonium gradient also tends to reduce the charge on eluted compounds reducing their affinity for the column. The peaks at to 5 CV are acidic or neutral compounds. Alkaloids eluted between 12 and 21 CV, and at 5 CV. Acetic acid and ammonia are both volatile and can be removed by rotary evaporation or lyophilization. Formic acid also works well in this application. 1 8 6 4 2 B Solvent Figure 3 demonstrates the double gradient used to purify basic compounds from a tar sample. The tar was dissolved in toluene containing 5% glacial acetic acid. After the sample was loaded, the column was manually washed with toluene to elute un-retained material followed by 2-propanol to remove the toluene. A variety of compounds were eluted. The large peak beginning at ~42 CV probably was insoluble in the aqueous solution as a free base and eluted in the 2-propanol wash. Table 1: Suggested gradient for SCX column Segment Length (CV) %B B Solvent Start 5% acid in water (B1) 1 5% acid in water (B1)- wash off un-retained material 2 5 5% acid in water (B1)- elute weak bases 5% acid in water (B1) 5 5% acid in water (B1)- wash off acid 15 5 5% NH 4 OH in water (B2)- elute stronger bases 5 5 5% NH 4 OH in water (B2) 5% acid in water (B1) 15 5% acid in water (B1)- wash off slow eluting, neutral compounds Note The acid could be acetic or formic acid. The alcohol could be methanol, ethanol, or propanol..6 6 Abs (All Wavelength).4.2. 4 2 Solvent B1 (%) Solvent B2 (%) 2 4 Figure 3: Cationic compounds eluted from a tar sample

Dissolution in a Non-Aqueous Solvent Using Water as the A Solvent.6 1.2 1 9 9.5.4 8 7.15 8 7 Abs (27).3.2.1 6 5 4 3 2 Abs (27).1.5 6 5 4 3 2 1 1. 5 1 15 2. 5 1 15 2 1 1 9 9 1. 8 1. 8 Abs (27).8.6.4 7 6 5 4 3 Abs (27).8.6.4 7 6 5 4 3.2. 5 1 15 2 Figure 4: Caffeine dissolved in acidic water (top) exhibits bleed-through compared to the same compound dissolved in acidic methanol (bottom) The compounds need to be ionized in order to interact with the column, so the sample is dissolved in acid. Dissolving the sample in minimum water improves the peak shape and reduces early elution from the column. Figure 4 shows an equivalent sample of caffeine eluted using the same method. The sample on the top of Figure 4 was dissolved in acidic water and bleeds off the column during the wash. The second sample dissolved in acidic methanol remains entirely retained until the gradient is run. For both runs, the eluting solvent is 5% acetic acid in water. 2 1.2. 5 1 15 2 Figure 5: Washing the column with water (top) elutes the compound early compared to washing with methanol (bottom) For the experiments in Figure 5, caffeine was run in the same fashion except that solvent A was freshly drawn and degassed 17.4 M water. Water was able to displace caffeine from the column, causing it to elute (Figure 5, top) while using methanol as the A solvent caused the compound to be retained. The eluting solvent was 5% acetic acid in water in both experiments. The wash solvent could be a water-miscible solvent such as alcohols, acetonitrile, or acetone. The experiment in Figure 3 was washed with toluene, followed by 2-propanol. 2 1

SAX Examples Running an SAX column uses a single gradient as the sample is displaced by acetate or formate. Concurrently, the ph is being lowered to generate the free acid. Green Tea Extract Abs (275 nm) 2.5 2. 1..5. 1 2 3 4 Figure 6: Green tea extract on a RediSep SAX column 1 8 6 4 2 The tar sample (11.7 g) was dissolved in 25 ml toluene; 3 ml concentrated ammonium hydroxide was added. To this mixture was added 2-propanol until the mixture was homogeneous (5 ml). This was loaded onto a 17 g RediSep Rf SAX column (69-223-392) previously conditioned and then washed with toluene. The column was then manually washed with toluene to elute non-binding material followed by 1 CV 2-propanol. The acidic compounds were eluted with 5% acetic acid in water. For this run, some material eluted after the gradient was complete, likely an acidic compound that is insoluble in the aqueous eluting solvent. A general solvent method for the SAX column would be: Segment Length (CV) %B B Solvent (Acetic or Formic Acid) Start 5% acid in water (B1) 1 1 5% acid in water (B1) 5 1 5% acid in water (B1) 5% acid in water (B1) 5 5% acid in water (B1) An example of SAX purification is shown in Figure 6. A methanolic extract of green tea (.75 g) was dissolved in methanol containing 5% ammonium hydroxide and the mixture was loaded onto a 17 g RediSep Rf SAX column (PN 69-223-392). The column was washed with 1 CV methanol to elute basic and neutral compounds (peak prior to 5 CV) followed by a gradient with 5% acetic acid in water. The anti-oxidants eluted after 15 CV. Tar.4 1.35.3 8.25.2.15.1.5 6 4 2. 5 1 15 2 Figure 7: SAX purification of anionic components from tar

Using Water as the A Solvent.4.35.3.25.2.15.1.5. 5 1 15 2.5 1 8 6 4 2 1.4 8.3.2 6 4.1 2. 5 1 15 2 25 Figure 8: Column washed with water (top) and methanol (bottom); sample was retained better with methanol In Figure 8, both experiments were run with 5 mg catechin. The column in the top example was washed with water while the column in the bottom example was washed with methanol. Similar to the SCX column, washing the column with water caused the sample to elute early. It is recommend, like in the SCX experiments, to use a minimal amount of water when working with compounds. Teledyne Isco P.O. Box 82531, Lincoln, Nebraska, 6851 USA Toll-free: (8) 228-4373 Phone: (42) 464-231 Fax: (42) 465-391 E-mail: IscoInfo@teledyne.com Teledyne Isco is continually improving its products and reserves the right to change product specifications, replacement parts, schematics, and instructions without notice.