NVLAP Lab Code 500077-0 Report Number: Model: PL06803-001A BPAR30S-0803040C-12DE26-1C100 Date: 9/26/2015 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers Cree, Inc 4600 Silicon Drive Durham, NC 27703 Prepared By: Approved By: Siddhartha Kollipara, Photometric Technician Christopher McLaurin, Photometric Specialist C r e e, I n c 4 6 0 0 S i l i c o n D r i v e D u r h a m, N C 2 7 7 0 3 Page 1 of 12 This report contains data that are not covered by the NVLAP accreditation.
NVLAP Lab Code 500077-0 Product Information Manufacturer Model Number (SKU) Serial Number LED Type Cree Inc BPAR30S-0803040C-12DE26-1C100 RC01 Lextar PB40H02 Product Description Cree LED PAR lamp, plastic bulb with textured lens, Edison base in white plastic housing and white painted heat sink. Driver Information (Where Applicable) Integral Length Diameter 3.50 3.75 Sample The following sample was submitted for evaluation C r e e, I n c 4 6 0 0 S i l i c o n D r i v e D u r h a m, N C 2 7 7 0 3 Page 2 of 12
NVLAP Lab Code 500077-0 Key Photometric Data Sphere Output Goniophotometer Luminous Flux 829.9 822.6 lm Efficacy 82.50 81.67 lm/w Correlated Color Temperature (CCT) 3034 K Color Rendering Index (CRI) 93 R 9 65 Duv -0.00029 S/P Ratio* 1.48 Sphere Goniophotometer Electrical Measurements 120V 120V Input Wattage 10.06 10.07 W Input Frequency 60 60 Hz Input Current.085.085 A Input Voltage 120.07 120.15 V Power Factor.979.972 Off-State Power 0 0 W Total Harmonic Distortion (Voltage).04 - % Total Harmonic Distortion (Amperage) 14.73 - % Luminous Intensity Distribution Goniophotometer Maximum Candela 1474.9 Cd Beam Angle 42.2 Field of View 67.0 Color Angular Uniformity 0.00077 Key Test Parameters Sphere Output Goniophotometer Stabilization Time 58 60 min Total Operating Time (Stabilization + Test) 58 70 min Ambient Temperature 24.5 25.2 C C r e e, I n c 4 6 0 0 S i l i c o n D r i v e D u r h a m, N C 2 7 7 0 3 Page 3 of 12
NVLAP Lab Code 500077-0 Chromaticity Coordinates x y u v u v Duv 0.4341 0.4024 0.2495 0.3469 0.2495 0.5203-0.00029 Color Rendering Index Details Ra R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14 93 95 100 97 91 94 97 90 83 65 98 91 79 97 99 Chromaticity Diagram 0.43 3000 K 2700 K 3500 K 0.41 4000 K 0.39 4500 K CCy 0.37 5700 K 5000 K 3034 0.35 6500 K 0.33 0.31 0.29 0.28 0.30 0.32 0.34 0.36 0.38 0.40 0.42 0.44 0.46 0.48 0.50 CCx C r e e, I n c 4 6 0 0 S i l i c o n D r i v e D u r h a m, N C 2 7 7 0 3 Page 4 of 12
Spectral Distribution NVLAP Lab Code 500077-0 λ(nm) W/nm λ(nm) W/nm λ(nm) W/nm 0.018 0.016 0.014 360 0.000017 530 0.009049 700 0.005551 370 0.000024 540 0.009865 710 0.004325 380 0.000048 550 0.010590 720 0.003374 390 0.000015 560 0.011320 730 0.002558 400 0.000015 570 0.012171 740 0.001883 410 0.000005 580 0.013152 750 0.001426 420 0.000106 590 0.014260 760 0.001071 430 0.000393 600 0.015315 770 0.000794 440 0.001433 610 0.016154 780 0.000596 450 0.005595 620 0.016492 790 0.000437 460 0.008721 630 0.016258 800 0.000325 470 0.007643 640 0.015408 810 0.000248 480 0.005944 650 0.014091 820 0.000172 490 0.005656 660 0.012446 830 0.000133 500 0.006151 670 0.010554 510 0.007080 680 0.008717 520 0.008119 690 0.007062 Dominant Wavelength 582 nm Peak Wavelength: 621 nm Spectral Power Distribution (W/nm) Radiant Flux (W) 0.012 0.01 0.008 0.006 0.004 0.002 0 350 400 450 500 550 600 650 700 750 800 850 Wavelength (nm) C r e e, I n c 4 6 0 0 S i l i c o n D r i v e D u r h a m, N C 2 7 7 0 3 Page 5 of 12
Zonal Lumen Summary NVLAP Lab Code 500077-0 Zone Lumens % of Total Zone Lumens % of Total 0-5 34.9 4.2% 90-95 0.0 0% 5-10 100.2 12.2% 95-100 0 0% 10-15 147.6 17.9% 100-105 0 0% 15-20 159.7 19.4% 105-110 0 0% 20-25 133.9 16.3% 110-115 0 0% 25-30 90.1 11.0% 115-120 0 0% 30-35 51.3 6.2% 120-125 0 0% 35-40 27.5 3.3% 125-130 0 0% 40-45 16.7 2.0% 130-135 0 0% 45-50 12.8 1.6% 135-140 0 0% 50-55 11.3 1.4% 140-145 0 0% 55-60 9.8 1.2% 145-150 0 0% 60-65 8.4 1.0% 150-155 0 0% 65-70 6.8 0.8% 155-160 0 0% 70-75 5.2 0.6% 160-165 0 0% 75-80 3.6 0.4% 165-170 0 0% 80-85 2.0 0.2% 170-175 0 0% 85-90 0.6 0.1% 175-180 0 0% Total 822.6 lm 100% C r e e, I n c 4 6 0 0 S i l i c o n D r i v e D u r h a m, N C 2 7 7 0 3 Page 6 of 12
Candela Plots NVLAP Lab Code 500077-0 Isofootcandle Plot C r e e, I n c 4 6 0 0 S i l i c o n D r i v e D u r h a m, N C 2 7 7 0 3 Page 7 of 12
Candela Tabulations NVLAP Lab Code 500077-0 0 0 1475 2.5 1469 5 1449 7.5 1412 10 1352 12.5 1261 15 1134 17.5 982 20 812 22.5 641 25 485 27.5 353 30 248 32.5 170 35 115 37.5 80 40 57 42.5 44 45 36 47.5 31 50 28 52.5 26 55 24 57.5 21 60 19 62.5 17 65 15 67.5 14 70 12 72.5 10 75 8 77.5 7 80 5 82.5 4 85 2 87.5 1 90 0 C r e e, I n c 4 6 0 0 S i l i c o n D r i v e D u r h a m, N C 2 7 7 0 3 Page 8 of 12
NVLAP Lab Code 500077-0 Candela Tabulations (Continued) 0 92.5 0 95 0 97.5 0 100 0 102.5 0 105 0 107.5 0 110 0 112.5 0 115 0 117.5 0 120 0 122.5 0 125 0 127.5 0 130 0 132.5 0 135 0 137.5 0 140 0 142.5 0 145 0 147.5 0 150 0 152.5 0 155 0 157.5 0 160 0 162.5 0 165 0 167.5 0 170 0 172.5 0 175 0 177.5 0 180 0 C r e e, I n c 4 6 0 0 S i l i c o n D r i v e D u r h a m, N C 2 7 7 0 3 Page 9 of 12
Integrating Sphere Equipment List NVLAP Lab Code 500077-0 Description Manufacturer Model Serial Number 2M Sphere Labsphere AS-02481-000, LMS-760 1228124709 CCD Array Spectrometer Otsuka MC-9801 98010117 Programmable AC Source Chroma 61601 616010001952 Power Analyzer Xitron 2801 28011212013 Aux Lamp Power Supply Labsphere LPS-100-0833 1205124607 Goniophotometer Equipment List Description Manufacturer Model Serial Number AC Power Source Chroma 61602 616020002254 DC Power Source Chroma 62006P-300-8 62006PE00454 Type C Goniophotometer Mayer Engineering ME-GONC01 SN0001 Spectroradiometer Ocean Optics Jaz 110800304 Power Meter Yokogawa WT210 91L137840 Optometer Gigahertz-Optik P9801 14564M Test Methods Used: Title ANSI C82.77:2002 CIE Pub. 13.3:1995 CIE Pub. 15:2004 IES LM-58:1994 IES LM-65:2001 IES LM-79:2008 Description Harmonic Emission Limits- Related Power Quality Reqt s for Lighting Equipment Method of Measuring and Specifying Color Rendering of Light Sources Colorimetry Spectroradiometric Measurements Single-Ended Compact Fluorescent Lamps Life Test Performance Electrical and Photometric Measurements of Solid-State Lighting Products Reference Standard Used: Equipment 2m Sphere Type C Goniophotometer Description Tungsten Halogen Omni-Directional 75W Calibration Lamp, Serial Number H111 Tungsten Halogen Omni-Directional 75W Calibration Lamp, Serial Number 208C C r e e, I n c 4 6 0 0 S i l i c o n D r i v e D u r h a m, N C 2 7 7 0 3 Page 10 of 12
Disclaimers: NVLAP Lab Code 500077-0 This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of the federal government. The results contained in this report pertain only to the tested sample. This report shall not be reproduced, except in full, without written approval of the CESTL. * Items marked with a single asterisk are not covered by the NVLAP accreditation. In the event that the recorded temperature is outside of 25 ± 1 C, this is considered a non-standard condition. ** In the event that testing is subcontracted, test results in this report marked with the symbol **, or noted as Goniophotometer, were performed by the subcontracted laboratory identified in the footer on the first page of this report. Subcontracted testing is strictly goniophotometer based. All other tests are performed using an integrating sphere. The goniophotometer information in the equipment list, report items marked with **, or results specifically identified as Goniophotometer, are the actual equipment used, and test results produced, by the subcontracted laboratory. Document Revision History: Each subsequent revision of this report replaces the preceding report. Date Rev DCN # Change at the time of this test By Approval 9/26/15 A DMS Origination S. Kollipara C. McLaurin C r e e, I n c 4 6 0 0 S i l i c o n D r i v e D u r h a m, N C 2 7 7 0 3 Page 11 of 12
NVLAP Lab Code 500077-0 Additional Comments: This luminaire was tested in the base up orientation Sphere picture Goniophotometer Picture C r e e, I n c 4 6 0 0 S i l i c o n D r i v e D u r h a m, N C 2 7 7 0 3 Page 12 of 12