Available online at ScienceDirect. Procedia Engineering 150 (2016 )

Similar documents
Available online at ScienceDirect. Procedia Engineering 150 (2016 )

Effective Modes of Axial Balancing of Centrifugal Pump Rotor

Available online at ScienceDirect. Procedia Engineering 106 (2015 ) Dynamics and Vibroacoustics of Machines (DVM2014)

Flow Structure Investigation in the Lateral Inlet Branches of Hydraulic Machines and Some Recommendations on Their Designing

Available online at ScienceDirect. Procedia Engineering 150 (2016 )

Available online at ScienceDirect. Procedia Engineering 157 (2016 )

Available online at ScienceDirect. Procedia Engineering 152 (2016 ) 13 17

Available online at ScienceDirect. Procedia Engineering 176 (2017 ) Dynamics and Vibroacoustics of Machines (DVM2016)

Available online at ScienceDirect. Energy Procedia 63 (2014 ) GHGT-12

Available online at ScienceDirect. Procedia Engineering 150 (2016 )

Y.; Kobayashi, H.; Inatani, Y. Citation Physics Procedia (2015), 67: Right article under the CC BY-NC-ND

Use of Near Infrared Spectroscopy for in- and off-line performance determination of continuous and batch powder mixers: opportunities & challenges

Available online at ScienceDirect. Procedia Engineering 113 (2015 )

Available online at ScienceDirect. Physics Procedia 67 (2015 ) Superfluid helium heat pipe. P.

Applied Fluid Mechanics

Available online at ScienceDirect. Procedia Engineering 105 (2015 )

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Available online at ScienceDirect. Procedia Engineering 113 (2015 )

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

ScienceDirect Abstract

Accumulators Virginia KMP Suction Line Accumulators

Available online at ScienceDirect. Physics Procedia 67 (2015 )

t, s T, C 2. Temperature fluctuations.

9. Pumps (compressors & turbines) Partly based on Chapter 10 of the De Nevers textbook.

Experimental Studies for Determining Gas Flow Rate Accidental Release on Linear Part of Pipeline

ScienceDirect. Contact Deformations under the Influence of Measurement Force

Available online at ScienceDirect. Procedia Engineering 133 (2015 ) th Fatigue Design conference, Fatigue Design 2015

Chemical Engineering 3P04 Process Control Tutorial # 1 Learning goals

Available online at ScienceDirect. Procedia Engineering 174 (2017 )

Available online at ScienceDirect. Procedia Engineering 191 (2017 )

Available online at ScienceDirect. Physics Procedia 71 (2015 )

ScienceDirect. Active and semi active vibration isolation systems based on magnetorheological materials

The Fluid Flow in the T-Junction. The Comparison of the Numerical Modeling and Piv Measurement

INVESTIGATION OF THE ENERGY OF THE STOCHASTIC MOTION OF CAVITATION BUBBLES IN THE SEPARATOR OF THE AXIAL VALVE, DEPENDING ON THE DEGREE OF ITS OPENING

SOME ASPECTS OF COOLANT CHEMISTRY SAFETY REGULATIONS AT RUSSIA S NPP WITH FAST REACTORS

Study on hydraulic direct-acting relief valve

Available online at ScienceDirect. Procedia Engineering 136 (2016 )

Available online at ScienceDirect. Procedia Engineering 152 (2016 )

Available online at ScienceDirect. Procedia Engineering 91 (2014 ) 63 68

666. Controllable vibro-protective system for the driver seat of a multi-axis vehicle

Available online at ScienceDirect. Procedia Engineering 84 (2014 )

CHAPTER EIGHT P U M P I N G O F L I Q U I D S

USE OF VENTURI JETS LOCATED OUT OF TUNNELS FOR THEIR VENTILATION DURING THE PERIODS OF TUNNELING COMPLETION OR AT THEIR RECONSTRUCTION

Experimental and Numerical Investigations of the Effect of Net Positive Suction Head on Water Hammer In Pipeline Systems

Study of adsorption and desorption of asphaltene sediments inhibitor in the bottomhole formation zone

Available online at ScienceDirect. Procedia Engineering 90 (2014 )

INTERNATIONAL OIML D 25 DOCUMENT. Vortex meters used in measuring systems for fluids ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Available online at ScienceDirect. Procedia Engineering 161 (2016 ) Žilina, Slovakia

CHAPTER THREE FLUID MECHANICS

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Available online at ScienceDirect. Procedia Engineering 129 (2015 ) International Conference on Industrial Engineering

CV3000 Series. Characterized Insert Control Valves

4. Objectives of Research work

Available online at ScienceDirect. Procedia Engineering 119 (2015 ) 13 18

CHAPTER 5 MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES

Conception of effective number of lanes as basis of traffic optimization

Available online at ScienceDirect. Procedia Engineering 100 (2015 ) 41 45

Available online at ScienceDirect. Physics Procedia 74 (2015 )

NATIONAL CERTIFICATE (VOCATIONAL) APPLIED ENGINEERING TECHNOLOGY NQF LEVEL 4 NOVEMBER 2009

Available online at ScienceDirect. Nuclear power plant explosions at Fukushima-Daiichi. Takashi Tsuruda*

Reliability of fluid systems

Experiment for Justification the Reliability of Passive Safety System in NPP

ScienceDirect. Fatigue life from sine-on-random excitations

Department of Energy Fundamentals Handbook. THERMODYNAMICS, HEAT TRANSFER, AND FLUID FLOW, Module 3 Fluid Flow

THE EXPERIMENTAL STUDY OF THE EFFECT OF ADDING HIGH-MOLECULAR POLYMERS ON HEAT TRANSFER CHARACTERISTICS OF NANOFLUIDS

Hydraulic modeling assessment Copyright 2010, Optimized Technical Solutions, LLC

Available online at ScienceDirect. Procedia Technology 23 (2016 ) 42 50

Hydraulic (Piezometric) Grade Lines (HGL) and

LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS

arxiv: v1 [physics.app-ph] 25 Mar 2018

Available online at ScienceDirect. Physics Procedia 71 (2015 ) 30 34

CERN, 1211 Geneva 23, Switzerland *Laboratoire des Signaux et Systèmes, UMR 8506 CNRS-Supélec, Gif-sur-Yvette, France

Available online at ScienceDirect. Procedia Engineering 100 (2015 ) 56 63

Chapter 7 The Energy Equation

Chemistry Instrumental Analysis Lecture 31. Chem 4631

Cooling Water Flow Regulator

Available online at ScienceDirect. Procedia Engineering 81 (2014 ) Fengfeng Hu, Yu Sun*, Binbin Peng

Available online at ScienceDirect. Procedia Engineering 144 (2016 )

Available online at ScienceDirect. 20th European Conference on Fracture (ECF20) Yu.G. Matvienko*

Optimization and Numerical Simulation of Multi-layer Microchannel Heat Sink

EPIV electronic pressure-independent characterised control valve EPIV

Solenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil

Electronic pressure-independent characterised control valve EPIV

Available online at ScienceDirect. Procedia Engineering 132 (2015 )

Solenoid valves Type EVUL

Experimental Investigation on the Acoustic Scattering Matrix for a Centrifugal Pump

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2.

ScienceDirect. Centre of pressure detection and analysis with a high-resolution and low-cost smart insole

Simulation of process of hot pilgrim rolling

MODELING OF PIPELINE VIBRATION UNDER THE PRESSURE RIPPLES IN THE WORKING FLUID

Chapter Four Hydraulic Machines

Available online at ScienceDirect. Energy Procedia 69 (2015 )

Experiment (4): Flow measurement

INTERNATIONAL STANDARD

Pumping Stations Design For Infrastructure Master Program Engineering Faculty-IUG

TOTAL HEAD, N.P.S.H. AND OTHER CALCULATION EXAMPLES Jacques Chaurette p. eng., June 2003

Pressure and Flow Characteristics

P & I Design Limited. 2 Reed Street, Gladstone Industrial Estate, Thornaby, TS17 7AF. Tel: +44 (0) Fax: +44 (0)

Comparison of discharge measurements - Thermodynamic to US Clamp- On, stationary US and Needle Opening Curve

Transcription:

Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 150 (2016 ) 260 265 International Conference on Industrial Engineering, ICIE 2016 Method for Determining of the Valve Cavitation Characteristics I.R. Chinyaev, A.V. Fominykh, E.A. Pochivalov* OOO NPF «MKT-ASDM», Naberezhnayaul., 2A, Kurgan, 640000, The Russian Federation Abstract Reliable and safe operation of piping systems depends on the cavitation processes occurring in its environment. Based on the analysis of cavitation processes studies, the existing methods of cavitation characteristics determination and experience in the use of GOST R 55508-2013 the authors proposed a method of experimental determination of the cavitation coefficient and developed the technique of experimental data processing when determining these coefficients. Based on the experimental data, the authors make conclusions about the influence of pressure before and after the tested valve and the differential pressure flow on the bandwidth characteristic and cavitation characteristic of valves. 2016 The Authors. Published by by Elsevier Ltd. Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). Peer-review under responsibility of the organizing committee of ICIE 2016. Peer-review under responsibility of the organizing committee of ICIE 2016 Keywords:cell valve; the method of determining; cavitation characteristics. 1. Introduction Cell valves are widely used because of the advantages: the opportunity to get any throughput characteristic by location and size of the holes in the cage, balanced plug, anti-cavitation properties. 2. The relevance Reliable and safe operation of piping systems depends on the cavitation processes occurring in its environment. Requirements to accuracy of regulation of flows increase due to development of automated control systems of techno-logical processes. Research questions and establish patterns of movement of liquid in the valves and fluid interaction with a gate node for the purpose of de-termination of rational values of design parameters of the valves * Corresponding author. Tel.: +8-3522-65-50-18. E-mail address: poshivalov_79@mail.ru 1877-7058 2016 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). Peer-review under responsibility of the organizing committee of ICIE 2016 doi:10.1016/j.proeng.2016.06.759

I.R. Chinyaev et al. / Procedia Engineering 150 ( 2016 ) 260 265 261 to improve the control accuracy of the service environment and avoid damage to the parts of the valve in the stroke range of the plunger is important. 3. Statement of the problem Based on the analysis of existing methods of determining cavitation characteristics and experience in the use of GOST R 55508-2013 to develop proposals for improving methods of experimental determination of the cavita-tion coefficient and the coefficient critical pressure valves and to develop a data processing procedure in the determination of these coefficients. To determine the influence of pressure before the valve, after the valve and the differential pressure at the hydraulic and cavitation characteristics of the valve. 4. The theoretical part In the process of solving the tasks performed by the authors analysis of studies of cavitation processes [1-7], methods for determining the cavitation characteristics of pipeline valves [8-12]. Developed samples of pipe fittings with improved characteristics [13-17]. Performed calculation and experimental studies [18-21]. Production tests showed increasing the service life significantly [22]. Developed the design documentation and manufactured two prototypes of the cell valve DN 50 PN 160 [23-27]. In accordance with GOST R 55508-2013 [8] defined the hydraulic characteristics of cell valve DN50 PN160 in the laboratory of OOO NPF «MKT-ASDM». When the experimental determination of GOST R 55508-2013 [8] cavitation characteristics of the valve of the cell 189 is made of measurements of the operation of the plunger 48 and the measurements when the water flow under the plunger. In this case, the Reynolds number was varied from 10000 to 500000. The cavitation characteristics were determined at the minimum possible pressure value, P 2 is equal to 124630...202650 Pa (absolute). The pressure drop P rises due to the increase in pressure P 1. According to the method GOST R 55508-2013 failed to determine the beginning of the deviation of flow characteristics Q = f( P) from linear dependence in the entire stroke range of the plunger. In this case, through the transparent glass in the pipeline after the valve was observed for two-phase fluid (gas bubbles and liquid). Based on the analysis of existing methods of determining cavitation characteristics [9-12] and experience [8] proposed the method of experimental determination of the cavitation coefficient and the coefficient critical pressure according to numbers of paragraphs GOST R 55508-2013[8]: 8.2.3 Set the value to RA pressure P 1 = 1,1 MPa (absolute). 8.2.4 Set the pressure value P 2 after RA 0,2 MPa less than P 1. 8.2.5 To measure water flow rate Q, temperature t, pressure at the inlet P 1 and outlet pressure P 2. 8.2.6 Armature of the stand to maintain the pressure P 1 constant, and the pressure P 2 be reduced to values 0,7; 0,6; 0,5; 0,4; 0,30; 0,20; 0,15 MPa and P 2 low, making measurements at each value of P 2 in accordance with 8.2.5. 8.2.7 Set the pressure to RA P 1 = 1,6 MPa. To maintain P 1 constant. P 2 to install sequentially 1,1; 0,9; 0,7; 0,6; 0,5; 0,4; 0,30; 0,20; 0,15 MPa and P 2 low, making measurements at each value of P 2 in accordance with 8.2.5. 8.2.8 To process the experimental data. 1. Build the dependencies Q = f( P) for each position REl. 2. Processing of experimental data when determining coefficient : for the data array that satisfy the condition for single-phase flow in a quadratic field, to determine the coefficients of the regression equation having the form: Q a0 a1 P; (1) for the rest of the data array, including the last point of the previous array to determine the coefficients of the regression equation having the form: 2 Q a0 a1 P a 2 ( P) ; (2)

262 I.R. Chinyaev et al. / Procedia Engineering 150 ( 2016 ) 260 265 solve the system of these equations. The solution to the system of equations is the point with coordinates Q and P, which defines the deviation of flow characteristics Q=f( P) from the linear dependence. Cavitation factor is determined by: Kc P c/(p1 P.. ), (3) where P pressure drop across the valve corresponding to the beginning of the deviation of the flow characteristic of the form Q = f( P) from linear dependence, Pa; 1 the absolute pressure before the valve, Pa; absolute pressure of saturated vapor, Pa. 3. Processing of experimental data when determining the critical pressure m : - to determine the derivative of equation (2), equate to zero. The solution of the equation is the point with coordinates Q and P, which defines the mode locking of consumption. The ratio of the critical pressure drop is defined by: K m P m/(p1 rc P ). (4) where P m critical differential pressure, the differential pressure corresponding to the locking of the discharge, Pa; r semi-empirical coefficient critical ratio of pressure-dependent physical properties of the medium (water). 4. Next, according to GOST R 55508-2013. Further investigation of the cavitation characteristics of the valve of the cell the most extensively held with the water supply to the plunger and the plunger position h = 0,2, since in this position of the plunger is most pronounced occur cavitation processes and most fully realized the possibilities of the stand. Performed research of the influence of the pressure P 1 when the values 1,1; 1,6; 2,1 and 2,6 MPa (11,0; 16,0; 21,0; 26,0 kg/cm 2 ) cavitation factor and the ratio of the critical pressure drop m, Fig. 1. Processing of experimental data in the determination of the factors and m carried out by the proposed method. The solution to the system of equations for each value of the pressure P 1 is the point with coordinates Q and P, which defines the deviation of flow characteristics Q=f( P) from the linear dependence, table 1. Table 1. Dependence of the coefficient cavitation from the pressure P 1. Pressure P1, kg/cm2 11,0 16,0 21,0 26,0 P 2,760 3,089 3,615 3,982 P, kg/cm2 7,617 9,542 13,069 15,856 0,692 0,596 0,622 0,610 The average value of four measurements of the =0,630. The maximum deviation from the average value obtained is 9,8% at P 1 =11,0 kg/cm 2. The average value of three measurements at P 1 =16,0; 21,0 and 26,0 kg/cm 2 =0,6093, and the maximum deviation from the average value does not exceed 2,2%. The results of the experiment showed that more accurate values of the cavitation coefficient can be determined if the values of pressure to test the valve more than 1,6 MPa (16,0 kg/cm 2 ). Solution of quadratic equation for all values of pressure P 1, Fig. 1, are the points with coordinates Q and P, which define the start mode locking of consumption. The results of processing of experimental data when determining the critical pressure m are shown in table 2.

I.R. Chinyaev et al. / Procedia Engineering 150 ( 2016 ) 260 265 263 line 1, 4 2, 6 3, 7 5, 8 Pressure P 1, kg/cm 2 11,0 16,0 21,0 26,0 Fig. 1. The dependence of water flow through the cell valve from the square root of differential pressure (kg/cm 2 ), obtained by the proposed method when stroke of the plunger h = 0,2 When solving equations of the second degree the values of the coefficient critical pressure K m 1,0. Apparently, when approaching differential pressure maximum P max = P 1-0,0 dependence Q=f( P) more intensive approaches line parallel to the axis P than quadratic dependence. To create the maximum possible P max can creating a vacuum after IA. Plot of deviation of flow characteristics Q=f( P) from the linear dependence should be described by a polynomial of degree more than two. When testing water parameters, corresponding to GOST coefficient critical pressure has a K m value close to one. Table 2. The dependence coefficient of the critical pressure drop m from the pressure P 1. Pressure P 1, kg/cm 2 11,0 16,0 21,0 26,0 P 3,634 4,20 4,55 5,12 P, kg/cm 2 13,206 17,63 20,73 26,22 m 1,2 1,10 0,988 1,01 In the method described in [8], clause 8.2.7, p. 40 indicated: «The constancy of consumption implies that in RA occurred the locking of the flow». Further analysis of the graphs in Fig. 1 and Fig. 2 shows that all the rightmost points, the maximum possible, for all values of pressure P 1 are on the line obtained by the method of [8].

264 I.R. Chinyaev et al. / Procedia Engineering 150 ( 2016 ) 260 265 Odd - GOST R 55508-2013; even the proposed method line 1, 2 3, 4 5, 6 7, 8 9, 10 11, 12 13, 14 Stroke of the plunger, h 0,05 0,1 0,2 0,3 0,4 0,5 0,6 Fig. 2. The comparison of the dependences of the flow of water through the cell valve DN 50 PN 160 from the square root of differential pressure (kg/cm 2 ) obtained by the method of GOST R 55508-2013 and by the proposed method Locking of the flow rate by the method described in GOST R 55508-2013, can't occur, the locking of the flow is constant, because P 2 has a minimum value. For values to the right of P 1 flow regimes no. Dependence, obtained by the proposed method at different values of pressure P 1, for all positions of the plunger end with the line obtained by the method of GOST R 55508-2013, as the operation of the plunger, and when water is delivered under the plunger. Further research will be conducted taking into account the recommendations [1, 4, 24, 25, 28]. 5. Conclusions the results of detection of the cavitation criteria Developed proposals to improve the methodology for determining the cavitation characteristics of pipeline valves. Obtained values of the coefficient cavitation, and the coefficient of the critical pressure drop m cell valve DN 50 PN 160. References [1]R.R. Ionaitis, Concept and examples of renewal and modernization of pipe fittings and reinforcing security, Pipeline valves, and equipment. 4 (2014) 12 20. [2]R.R. Ionaitis, Passive elements of systems important to safety of nuclear installations, Publishing house of the MSTU, Bauman, Moscow, 2003. [3]E.E. Blagov, B.Y. Ivnitskiy, Throttle-control valves in the energy sector, Energy, Moscow, 1974. [4]E.E. Blagov, Prediction of flow regimes fluid in a hydraulic constriction de-vices, Armaturostroenie. 4 (2007) 45 52.

I.R. Chinyaev et al. / Procedia Engineering 150 ( 2016 ) 260 265 265 [5E.K. Spiridonov, S.Y. Bitiutskikh, Characteristics and calculation of cavitation jet mixer, Chemical and petroleum engineering. 4 (2015) 6 9. [6]E.K. Spiridonov, Characteristics and calculation of cavitation mixers, in: Proceeding of Industrial-Engineering, the international scientific and technical conference. (2015) 14 16. [7]E.K. Spiridonov, A.R. Ismagilov, Universal method of analysis and design of liquid-gas jet pumps, Hydraulic machines, hydro pneumatic automation, Current state and prospects of development, in: Proceeding of collection of scientific papers of the 8th all-russian scientifictechnical conference with international participation. (2014) 101 103. [8] GOST R 55508-2013, Pipeline fittings, The method of experimental determination of the hydraulic and cavitation characteristics, 2013. [9] Standard CKBA 029-2006, CJSC NPF Central design Bureau of valve industry, Pipeline fittings, The method of experimental determination of the hydraulic and cavitation characteristics, 2006. [10] RTM 108.711.02-79, Valves energy, Methods for determining throughput capacity of the regulatory bodies and the choice of the optimal flow characteristics, 1979. [11] R 4-163-77, Guidance material, The calculation and application of regulators in systems of automation of technological processes, 1977. [12]Y.A. Gorelov, Comments on the article, Armaturostroenie. 4 (2015) 55. [13]E.A. Pochivalov, S.A. Sukhov, A.V. Fominykh, I.R. Chinyaev, A.L. Shanaurin, RU Patent 138816. (2014). [14]G.A. Zaslavsky, V.A. Ryazanov, S.A. Sukhov, A.L. Shanaurin, I.R. Chinyaev, A.V. Fominykh, RU Patent 158069. (2015). [15]V.S. Eroshkin, I.R. Chinyaev, A.L. Shanaurin, G.A. Zaslavsky, V.A. Ryazanov, A.V. Fominykh, RU Patent119835. (2012). [16]R.S. Romanov, V.A. Ryazanov, A.V. Fominykh, A.L. Shanaurin, I.R. Chinyaev, RU Patent 2563944. (2015). [17]A.V. Matveev, V.A. Ryazanov, A.V. Fominykh, I.R. Chinyaev, A.L. Shanaurin, RU Patent 2549391. (2015). [18]I.R. Chinyaev, A.V. Fominykh, S.A. Sukhov, Improving the reliability and efficiency of slide gate shut-off and regulating valves, Exposition oil gas. 3 (2013) 80 82. [19]I.R. Chinyaev, A.V. Fominykh, E.A. Pochivalov, S.A. Sukhov, Determination of capacity characteristics valves shut-off and regulating, Exposition oil gas. 2 (2015) 38 40. [20]I.R. Chinyaev, A.V. Fominykh, V.S. Eroshkin, Cavitation in gate valve, Territory Neftegaz. 5 (2013) 48 49. [21]A.V. Fominykh, D.N. Ovchinnikov, I.R.Chinaev, Determination of hydraulic characteristics of locking and regulating valves, Agrarian Bulletin of the Urals. 2 (2012) 27 30. [22]S.A. Sukhov, Improving the efficiency of the regulatory process fluid flows through improved design of slide gate valves, Armaturostroenie. 1 (2014) 58 61. [23] GOST 12893-2005, Control valves single seat, double-seat and cellular, General technical conditions, 2005. [24]V.P. Eismont, Regulators, Publishing house Deaton, St. Petersburg, 2012. [25]D.F. Gurevich, Calculation and design of pipeline valves: Calculation of pipeline valves, Publishing house of the LCI, Moscow, 2008. [26]I.E. Idelchik, Handbook of hydraulic resistance, Mashinostroenie, Moscow, 1992. [27]A.D. Altshul, Hydraulic resistance, Nedra,Moscow, 1982. [28]V.I. Chernoshtan, E.E. Blagov, Experimental determination of the critical flow criterion, Armaturostroenie. 4 (2012) 50 57.