Determine the Inside Wall Temperature of DSTs using an Infrared Temperature Sensor

Similar documents
Determine the Inside Wall Temperature of DSTs using an Infrared Temperature Sensor

Inside Wall Temperature Measurements of DSTs Using an Infrared Temperature Sensor

BWXT Y-12 Y-12. A BWXT/Bechtel Enterprise SMALL, PORTABLE, LIGHTWEIGHT DT NEUTRON GENERATOR FOR USE WITH NMIS

INTERMOLECULAR POTENTIAL FUNCTIONS AND HIGH RESOLUTION MOLECULAR SPECTROSCOPY OF WEAKLY BOUND COMPLEXES. Final Progress Report

Plasma Response Control Using Advanced Feedback Techniques

Bulk Modulus Capacitor Load Cells

Data Comparisons Y-12 West Tower Data

Development of a High Intensity EBIT for Basic and Applied Science

BASAL CAMBRIAN BASELINE GEOLOGICAL CHARACTERIZATION COMPLETED

Three-Dimensional Silicon Photonic Crystals

PROJECT PROGRESS REPORT (03/lfi?lfibr-~/15/1998):

Analysis of Shane Telescope Aberration and After Collimation

(4) How do you develop an optimal signal detection technique from the knowledge of

FUSION TECHNOLOGY INSTITUTE

ASTER. Dose Rate Visualization of Radioisotope Thermoelectric. Generators. RECElVED BEC OF THIS DOCUMEMT IS UNLlMIi L, Hanford Company

Optimization of NSLS-II Blade X-ray Beam Position Monitors: from Photoemission type to Diamond Detector. P. Ilinski

PRECISION STUDIES OF NUCLEI

ASTER CONF-~W OSTI MAY DISTRIBUTION OF THIS

GA A22722 CENTRAL THOMSON SCATTERING UPGRADE ON DIII D

AC dipole based optics measurement and correction at RHIC

Safety Considerations for Laser Power on Metals in Contact with High Explosives-Experimental and Calculational Results

EXPLOSIVE PARTICLES PARVLENE ENCAPSUTION. lac0 b Sando v a t. Normal Process Development OCTOBER DEVEZOPMENT D I V I S I O N DEZEMBER 1971

Status and Progress of a Fault Current Limiting HTS Cable To Be Installed In The Consolidated Edison Grid

Cable Tracking System Proposal. Nick Friedman Experimenta1 Facilities Division. June 25,1993. Advanced Photon Source Argonne National Laboratory

Magnetic Measurements of the Elliptical Multipole Wiggler Prototype

N. Tsoupas, E. Rodger, J. Claus, H.W. Foelsche, and P. Wanderer Brookhaven National Laboratory Associated Universities, Inc. Upton, New York 11973

August 3,1999. Stiffness and Strength Properties for Basic Sandwich Material Core Types UCRL-JC B. Kim, R.M. Christensen.

GA A23736 EFFECTS OF CROSS-SECTION SHAPE ON L MODE AND H MODE ENERGY TRANSPORT

12/16/95-3/15/96 PERIOD MULTI-PARAMETER ON-LINE COAL BULK ANALYSIS. 2, 1. Thermal Neutron Flux in Coal: New Coal Container Geometry

Multi-Scale Chemical Process Modeling with Bayesian Nonparametric Regression

Microscale Chemistry Technology Exchange at Argonne National Laboratory - East

Simulation of Double-Null Divertor Plasmas with the UEDGE Code

Parametric Instabilities in Laser/Matter Interaction: From Noise Levels to Relativistic Regimes

Applications of Pulse Shape Analysis to HPGe Gamma-Ray Detectors

UPGRADED CALIBRATIONS OF THE THOMSON SYSTEM AT DIII D

Peak Reliability Delivering near real-time phase angle deltas using Inter-Control Center Communication Protocol (ICCP)

Turbulent Scaling in Fluids. Robert Ecke, MST-10 Ning Li, MST-10 Shi-Yi Li, T-13 Yuanming Liu, MST-10

The Impacts of Carbon Dioxide Storage in the Saline Arbuckle Aquifer on Water Quality in Freshwater Aquifers in Kansas

Valley-Fill Sandstones in the Kootenai Formation on the Crow Indian Reservation, South-Central Montana

GA A25658 PRECISION X-RAY OPTICAL DEPTH MEASUREMENTS IN ICF SHELLS

Flipping Bits in the James Webb Space Telescope s Cameras

UNIT OPERATIONS AND CHEMICAL PROCESSES. Alan M. Krichinsky

Quarterly Report April 1 - June 30, By: Shirley P. Dutton. Work Performed Under Contract No.: DE-FC22-95BC14936

Hydra Fault Current Limiting HTS Cable to be Installed in the Consolidated Edison Grid

Solid Phase Microextraction Analysis of B83 SLTs and Core B Compatibility Test Units

PROCEEDINGS THIRD WORKSHOP GEOTHERMAL RESERVOIR ENGINEERING. December 14-15,1977

ION EXCHANGE SEPARATION OF PLUTONIUM AND GALLIUM (1) Resource and Inventory Requirements, (2) Waste, Emissions, and Effluent, and (3) Facility Size

MAGNETICALLY CONTROLLED DEPOSITION OF METALS USING GAS PLASMA. Quarterly Progress Report April - June 1997

Scaling of divertor heat flux profile widths in DIII-D

Survey, Alignment and Beam Stability at the Advanced Light Source

PLASMA MASS DENSITY, SPECIES MIX AND FLUCTUATION DIAGNOSTICS USING FAST ALFVEN WAVE

4kU. Measurement of Storage Ring Motion at the Advanced Light Source. QSTt ERNESTORLANDO LAWRENCE BERKELEYNATIONAL LABORATORY

Development of a Parallel, 3D, Lattice Boltzmann Method CFD Solver for Simulation of Turbulent Reactor Flow

A Germanium Detector with Optimized Compton Veto for High Sensitivity at Low Energy

Tell uric prof i 1 es across the Darrough Known Geothermal Resource Area, Nevada. Harold Kaufniann. Open-file Report No.

Valley-Fill Sandstones in the Kootenai Formation on the Crow Indian Reservation, South-Central Montana

GA A26686 FAST ION EFFECTS DURING TEST BLANKET MODULE SIMULATION EXPERIMENTS IN DIII-D

Using the X-FEL to understand X-ray Thomson scattering for partially ionized plasmas

STP-TS THERMOPHYSICAL PROPERTIES OF WORKING GASES USED IN WORKING GAS TURBINE APPLICATIONS

Partial Discharge Characterization of High-Voltage Cables and Components

Plutonium 239 Equivalency Calculations

Introduction to Blackbody Sources

Modeling Laser and e-beam Generated Plasma-Plume Experiments Using LASNEX

GA A27806 TURBULENCE BEHAVIOR AND TRANSPORT RESPONSE APPROACHING BURNING PLASMA RELEVANT PARAMETERS

The temperature dependence of the C1+ propylene rate coefficient and the Arrhenius fit are shown in Figure 1.

To be published in the Proceedings of ICEC-22, Seoul Korea, July 2008 MICE Note 232 1

Response to Comment on "The National Ignition Facility Laser Performance Status"

RICE COAL COMBUSTION: EFFECT OF PROCESS CONDITIONS ON CHAR REACTIVITY. Quarterly Technical Report Performance Period: 10/1/94 42/31/94 (Quarter #13)

A Distributed Radiator, Heavy Ion Driven Inertial Confinement Fusion Target with Realistic, Multibeam Illumination Geometry

GA A26057 DEMONSTRATION OF ITER OPERATIONAL SCENARIOS ON DIII-D

RESEARCH OPPORTUNITIES AT THE CNS (Y-12 AND PANTEX) NUCLEAR DETECTION AND SENSOR TESTING CENTERS (NDSTC)

Colliding Crystalline Beams

A Geological and Geophysical Assessment of the Royal Center Gas Storage Field in North-Central Indiana, a Joint NIPSCO, DOE & GRI Case Study

Two-Screen Method for Determining Electron Beam Energy and Deflection from Laser Wakefield Acceleration

Equivalencing the Collector System of a Large Wind Power Plant

ADSORPTION ON NANOSURFACES: A DETAILED LOOK AT METAL CLUSTERS USING INFRARED SPECTROSCOPY

- High Energy Gull Generator

Curvature of a Cantilever Beam Subjected to an Equi-Biaxial Bending Moment. P. Krulevitch G. C. Johnson

MAGNETIC RESONANCE IMAGING OF SOLVENT TRANSPORT IN POLYMER NETWORKS

SciDAC CENTER FOR SIMULATION OF WAVE-PLASMA INTERACTIONS

Comparing 2-D Conduction Experiments with Simulation

Multicusp Sources for Ion Beam Lithography Applications

Abstract of paper proposed for the American Nuclear Society 1997 Winter Meeting Albuquerque, New Mexico November 16-20, 1997

Knott, M. May Future t r e n d s

Direct Determination of the Stacking Order in Gd 2 O 3 Epi-Layers on GaAs

Clifford K. Ho and Michael L. Wilson Sandia National Laboratories. P.O. Box Albuquerque, NM

OAK RIDGE NATIONAL LABORATORY

Excitations of the transversely polarized spin density. waves in chromium. E3-r 1s

Novel Nanoparticles for Ultrasensitive Detection and Spectroscopy

C o f l F - 9m307-- SPREADSHEET APPLICATION TO CLASSIFY RADIOACTIVE MATERIAL FOR SHIPMENTa. A. N. Brown

PROGRESS REPORT JULY TO SEPTEMBER

Introduction to Part III Examining wildlife distributions and abundance using boat surveys

FINAL REPORT INTEGRATING P-WAVE AND S-WAVE SEISMIC DATA TO IMPROVE CHARACTERIZATION OF OIL RESERVOIRS. Innocent J. Aluka

DISCLAIMER. and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.

Analog Technologies. ATEC1 49 Circular TEC Modules

EFFECTS OF AXIAL HEAT CONDUCTION AND MATERIAL PROPERTIES ON THE PERFORMANCE CHARACTERISTICS OF A THERMAL TRANSIENT ANEMOMETER PROBE

DE '! N0V ?

Fission-Fusion Neutron Source

RECXWH2 W/o s3-1

APPLICATION SINGLE ION ACTIVITY COEFFICIENTS TO DETERMINE SOLVENT EXTRACTION MECHANISM FOR COMPONENTS OF NUCLEAR WASTE

Transcription:

SUMMARY DOCUMENT Determine the Inside Wall Temperature of DSTs using an Infrared Temperature Sensor Date submitted: April 14, 2017 Prepared by: Aparna Aravelli, Ph.D. Florida International University Collaborators: Dwayne McDaniel, Ph.D., P.E. Clarice Davila, DOE Fellow Submitted to: Ruben Mendoza, Washington River Protection Solutions, LLC Terry Sams, Washington River Protection Solutions, LLC Dennis Washenfelder, Washington River Protection Solutions, LLC Gary Peterson, Department of Energy, Office of Environmental Management Genia McKinley, Department of Energy, Office of Environmental Management Work supported by: U.S. Department of Energy Office of Environmental Management Under Cooperative Agreement # DE-EM0000598

DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, nor any of its contractors, subcontractors, nor their employees makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe upon privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States government or any other agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States government or any agency thereof.

TABLE OF CONTENTS Introduction... 1 Method and Benefits... 1 Raytek Miniature Infrared Sensor... 2 IR sensor emissivity configuration... 2 Experimental Approach... 3 Results and Discussion... 5 Sensor emissivity configuration... 5 Engineering scale experiments... 6 Summary... 7 Works Cited... 8

Introduction Corrosion in double-shell storage tanks (DSTs) is one of the primary concerns at Hanford and other sites. It is managed by stringent operating specifications as given in OSD-T-151-00007 Operating Specifications for the Double-Shell Storage Tanks (OSD) [1]. One of the important parameters specified by OSD is the temperature which plays an important role in corrosion. In general, the tank temperatures are determined by various processes such as: taking samples at different locations, using measurement devices and, finally, modelling. Most of these methods provide approximations of the actual temperatures at various locations inside the DSTs. Hence, there is an immense need for accurate measurements and calculations of actual temperatures inside the tanks. Of particular interest is the temperature at the interface of the tank waste and the inner walls since it accounts for the region that is highly prone to corrosion. It is known that the actual temperatures in the tanks are measured from more than 10 feet away from the tank wall due to technical and equipment constraints [2]. The tank-wall interface temperatures are then estimated using mathematical models. Most of these models have not been validated. This defines the purpose of the present task. The present work is a supportive effort by the Applied Research Center (ARC) at Florida International University (FIU) for the U.S. Department of Energy (DOE) to investigate the use of an infrared (IR) sensor to measure the outer wall temperatures of the primary shell in the DST. This process is practical since the sensor is expected to piggy back on the scheduled inspection tools passing through the annulus of the DSTs. This document provides a summary of an experimental setup developed at FIU-ARC to represent the DSTs using rectangular tanks, calibrating and conducting emissivity adjustment tests on the mini IR sensor, defining the test procedures based on various parameters, conducting the experiments and analyzing the results obtained. Method and Benefits Measuring the wall temperature with an IR sensor can be used with the current inspection equipment or the sensor can be attached to an annulus inspection camera. At FIU, two robotic inspection tools are being developed and the IR sensor can easily be attached to either of them as a built-in or as a separate module. Piggy backing of the sensor to prescheduled operations allows for the collection of temperature data with minimal impact to ongoing tank farm operations. The temperature results thus obtained will serve multiple purposes, such as: (a) to ensure that the temperature limits are met and, if not, allowing for immediate corrections to be made; (b) to empirically calculate the physical properties and validate/evaluate the current thermal modeling capabilities; (c) to estimate the solid waste levels in the tanks using the temperature gradients; (d) to calibrate other equipment with 1

the IR sensor; and (e) to minimize the need for expensive and time consuming thermal modeling. Raytek Miniature Infrared Sensor The IR sensor chosen for the present tests is the Raytek MI3 [4]. It is a pyrometer (noncontact sensor) that includes a digital screen for the temperature display (Figure 1). It primarily consists of two parts: the sensing head and the digital communication box. Based on the specifications of the present task, the product has variable (adjustable) emissivity. The spectral range of the MI3 series is 8-14 µm with a response time of 130 ms and an accuracy of ±1ºC. It is 0.55 inches in diameter and 1.1 inches in length and has a distance spot ratio of 22:1. Also, a 98-foot cable is available for the sensing head and will need to be integrated with the tether of the inspection tool on which the sensor will be placed. IR sensor emissivity configuration The sensor needs to be adjusted for emissivity to correlate with the test material since each material has its own emissivity. The procedure adopted for calibrating the emissivity includes a number of steps and is described in detail next. Using literature values, the emissivity of the carbon steel material is used as a starting point for the IR sensor. The tank wall temperatures are measured using that emissivity value. The measured values are then compared to the actual temperatures on the wall obtained using a laser gun (non-contact pyrometer) or a thermocouple. In case of discrepancy, the emissivity is adjusted again and the process repeated until the exact emissivity of the material is obtained. This procedure ensures that the most accurate measurements are taken by the Raytek MI3 sensor. Figure 1. Raytek sensor [4] (right) and sensor head [4] (right). 2

Experimental Approach The present task requires the Raytek IR sensor to be attached to an inspection device and deployed into the annulus to scan the entire tank height for temperature measurements. A typical sketch of the process is as shown in Figure 2 (left). Figure 2. IR sensor through the annulus (left) and test set up as block diagram (right). The objective is to understand the thermal gradients in the tank and, hence, a test setup has been established [Figure 2 (right)] for the present research that represents the configuration of the tanks. The experimental setup consists of a rectangular stainless steel tank of dimensions 2 x4 x3. Fluid (water) is heated in the tank and a thick carbon steel plate of 1/2 inch thickness (replicating a section of the DST wall thickness) is suspended onto the fluid surface using strut channels and cables/rods. A side-mounted heater [4000 W immersion heater from Tempco (TAT 40002)] is used to increase the water temperature and measurements are recorded at various time intervals. The experimental set up of the tank is as shown in Figure 3(left). During the experiments, the tank is covered with insulation [Figure 3 (right)] to minimize the heat loss to the atmosphere and to acquire accurate data. Figure 3. Experimental set up (left) and tank covered with insulation (right). 3

The Raytek IR sensor is used to measure temperatures on the outer surface (exposed to the atmosphere) of the plate while it transfers heat from the hot water to the ambient air outside. Heat transfer calculations provide a prediction of the temperatures on the inner surface (exposed to the fluid). Also, thermocouples are inserted at various set points to obtain accurate readings. To validate the use of the Raytek IR sensor, temperature measurements are taken at the top surface using thermocouples. Initially, roller surface K-type thermocouples along with the universal thermocouple connectors (UTC-USB) were used manually to acquire the temperature data (results reported in the document FIU-ARC- 2016-800006470-04c-245). In the second stage of experiments, the process has been automated using permanently fixed hermitically sealed thermocouples (HSTs) [5] and the multiple channel data acquisition (DAQ) system from omega (OM-DAQ-USB-2401) [6]. The HSTs were fixed onto the outer and inner surface (in contact with water) of the plate using a thermally conductive epoxy (OB-101) [7] to obtain real-time temperature measurements for continuous monitoring. The plate s inner surface with fixed HSTs is as shown in Figure 4 (left). The omega DAQ system is suitable for 8 differential or 16 single-ended analog inputs. It is user programmable for Type J, K, T, E, R, S, N, B thermocouples or voltage input and comes with customized Windows compatible software. It provides a 12-volt DC output for sensor excitation. Figure 4 (middle) shows the DAQ system attached to thermocouples while Figure 4 (right) shows the DAQ dashboard displaying temperature measurements. Figure 4. HSTs fixed under the plate (left), DAQ system with thermocouples (middle), DAQ dashboard (right). To conduct the experiments, a test matrix was defined based on the experimental set up and some approximations, and includes the following parameters: Temperature of water inside the tank - the temperature of the water bath in the tank was varied from 120ºF to 170ºF in intervals of 10ºF. Measurements along the length of the test piece - the HSTs were glued to both inner and outer surfaces of the plate at 1, 2 and 3 ft. distances from one end of the plate. 4

Temperature readings outer (top) surface readings were obtained using both HSTs and the Raytek sensor while the inner (bottom) surface readings were obtained using the permanently fixed HSTs. Results and Discussion Sensor emissivity configuration Initial experiments were conducted to determine the emissivity configuration of the Raytek IR sensor. Tests were performed to exactly determine the emissivity levels of two materials, carbon steel and stainless steel. The first experiment conducted used the carbon steel plate. Since the emissivity value of carbon steel is not precisely available in literature, an initial estimate of 0.75 was chosen and a range of values above and below the initial estimate was recorded. The experiment consisted of the ambient temperature measurement on a carbon steel plate (1/2 inch thick) using both a Raytek and a hermitically sealed thermocouple. The second experiment was conducted on the tank wall which is made of stainless steel. Emissivity values were changed from 0.3 to 0.6. The results obtained from these experiments are provided in 5

Table 1 and Table 2. In 6

Table 1, the temperature was recorded at three different points using both sensors. It is evident from the data that the temperature readings are close when the emissivity value ranges from 0.76 to 0.79 and is almost precise at 0.78. Also, it is to be noted that for the emissivity change from 0.7 to 0.8, the temperature values are precise within a maximum of 2-3ºF. Hence, the emissivity of carbon steel can be taken as 0.78. 7

Table 1. Experimental Results with ½ in Carbon Steel Plate (Temperature Readings in ºF) Emissivity (Raytek) Raytek (point 1) Raytek (point 2) Raytek (point 3) TC (point 1) TC (point 2) TC (point 3) 0.7 69.5 68.5 68.7 72.88 73.25 71.66 0.71 65.9 64.4 66.8 73.43 71.13 75.78 0.72 68.2 70.2 70.2 73.05 71.33 71.07 0.73 68.9 67.4 67.8 73.13 70.77 73.97 0.74 66.4 67.6 66.8 72.92 71.37 72.42 0.75 68.4 68.6 68.1 62.98 66.08 66.49 0.76 66.8 68.7 68.3 68.69 69.97 68.22 0.77 70.6 67.5 66.9 69.65 68.08 70.03 0.78 70.9 69.7 68.9 70.49 70.15 70.58 0.79 70.9 69.8 68.5 71.24 70.14 72.28 0.8 70.6 71.4 70.2 72.19 73.2 72.54 Table 2. Experimental Results on Stainless Steel Plate (Temperature Readings in ºF) Emissivity (Raytek) Raytek TC 0.3 40.4 73.42 0.4 52.8 73.54 0.5 61.4 73.23 0.6 73.7 74.34 In the case of stainless steel, it is observed ( Table 2) that the emissivity value of 0.4 to 0.5 provided an inaccurate temperature reading; however, at emissivity of 0.6, both the Raytek and the thermocouple readings are close, within less than a 1ºF temperature difference. Hence, the emissivity of stainless steel can be taken as 0.6. Engineering-scale experiments Engineering-scale experiments to measure the tank wall temperatures were conducted using the set up described in the previous section. Initially, manual experiments were conducted and the results are presented in the report FIU-ARC-2016-800006470-04c-245. In this report, the results obtained by the automated real-time monitoring system are reported. As described in the experimental approach section, the temperatures were measured at 6 points on the plate using HST s and at 3 top surface points using the Raytek sensor. The results obtained are tabulated in Table 3. 8

Table 3. Temperature (IR Sensor and HSTs) in ºF Data point T1 T2 T3 B1 B2 B3 R1 R2 R3 1 111.14 104.23 106.07 114.67 109.2 8 2 115.35 111.12 111.19 120.1 115.3 4 108.78 109.2 106.4 104.7 115.12 116.7 112.7 109.9 3 123.27 111.83 117.29 130.2 126.0 5 4 132.12 116.57 125.98 140.32 135.9 6 5 142.09 132.99 137.44 150.06 145.2 5 6 152.91 142.71 138.7 160.17 154.4 2 7 162.73 151.41 148.01 170.05 164.4 5 @T Top surface, B Bottom surface, R Raytek 125.4 132.9 128.9 124.6 135.27 143.9 141.7 133 144.53 152 145.7 141.7 153.67 157 155 153.1 163.6 165.2 167.2 166.2 In Table 3, columns T1, T2 and T3 represent the thermocouple readings while R1, R2 and R3 represent the Raytek sensor readings at the same locations. Hence, these can be directly compared. It is evident that the average difference between the corresponding readings for location 1 is 5.3ºF, while for locations 2 and 3 the average difference is 12.3ºF and 6.9ºF, respectively. It is also observed that the temperature difference increased with an increase in temperature. In most cases, the Raytek sensor showed a higher value. In addition, the temperatures at the top 3 locations (T1, T2 and T3) were compared to the bottom 3 locations (B1, B2 and B3) to investigate the heat transfer effects. From the results, it is seen that the average temperature difference was 6.5ºF, 11.4ºF, and 8.8ºF, respectively, for the three locations. According to theoretical calculations, the average readings can approximate to about 4-5ºF, taking into account the temperature gradients with location and time. Summary The data presented is based on engineering-scale experiments conducted to validate the use of Raytek mini IR sensors for use at the actual sites. HSTs were permanently fixed to the inner and outer surface of the test piece for accurate thermal measurements and validation. Also, a temperature range as specified for the DST s (120-170ºF) has been used. The experiments were conducted to investigate the sensitivity of the Raytek IR sensor to different emissivity values and materials. A method has been established to accurately calibrate and test the Raytek mini IR sensor. The tests were conducted with hot water as 9

the liquid medium. In future testing, real tank conditions may be stimulated by adding a slurry mixture to the tanks and investigating the effect of temperature gradients as measured by the mini IR sensor. In addition, integration of the IR sensor with inspection devices for deployment into the tanks and other pipelines will be investigated. To conclude, the Raytek sensor was calibrated and tested for temperature measurements and is found to be capable of temperature measurements in DSTs within specified limits. Works Cited [1] OSD-T-151-00007, Operating specifications for the Double-Shell Storage Tanks, Rev 1, Washington River Protection Solutions, Richland, WA. [2] Holsmith, B. (2015). Double Shell Tank Primary Wall Temperature Measurements: Suggested New Technology White Paper, Washington River Protection Solutions, Richland, WA, 2015. [3] The Principles of Noncontact Temperature Measurement, produced by Raytek available online at http://support.fluke.com/raytek-sales/download/asset/9250315_eng_d_w.pdf [4] www.raytek.com [5] http://www.omega.com/pptst/hstc.html [6]http://www.omega.com/search/esearch.asp?start=0&perPage=10&summary=yes&sort=rank& search=om-daq-usb-2401&submit=search&ori=om-daq-usb-2401 [7] http://www.omega.com/pptst/ob-100_ob-200_ot-200.html 10