Olumide Adebolu. Chromatographic Fidelity and Matrix /Analyte Solubility in Complex Polymer Systems using HPLC-MALD/I TOF MS

Similar documents
Laser desorption/ionization on the layer of graphene nanoparticles coupled with mass spectrometry for characterization of polymer

Macromolecular Chemistry

M M e M M H M M H. Ion Sources

Lecture 15: Introduction to mass spectrometry-i

MASS SPECTROMETRY. Topics

2,5-Dihydroxybenzoic. Figure 6.1. Chemical structures of several common matrix compounds.

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Mass spectrometry and elemental analysis

20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n

Molecular Mass Spectrometry

GPC/MS. Analysis of PET

Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. H i

Voyager-DE STR Biospectrometry Workstation Manufactured by PerSeptive Biosystems

Chemistry Instrumental Analysis Lecture 34. Chem 4631

Mass spectrometry gas phase transfer and instrumentation

Ionization Techniques Part IV

TANDEM MASS SPECTROSCOPY

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Harris: Quantitative Chemical Analysis, Eight Edition

Chapter 14. Molar Mass Distribution.

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

Application Note. Edgar Naegele. Abstract

1. The range of frequencies that a measurement is sensitive to is called the frequency

BIOINF 4399B Computational Proteomics and Metabolomics

LC-MS Based Metabolomics

LC and LC/MS Column Selection Flow Chart

MALDI-TOF: a powerful tool for the analysis of biomolecules and large organic molecules

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Lecture 8: Mass Spectrometry

Lecture 8: Mass Spectrometry

Use of High Speed/High Resolution Size-Based Chromatographic Separation of Polymeric Mixtures with Offline Infrared Detection

Molecular Weight Distribution of Living Chains in Polystyrene Pre-pared by Atom Transfer Radical Polymerization

4. How can fragmentation be useful in identifying compounds? Permits identification of branching not observed in soft ionization.

Mass spectrometric determination of the surface compositions of ethanol water mixtures

Mass Spectrometry. Electron Ionization and Chemical Ionization

Introduction. Chapter 1. Learning Objectives

New Product Update. HPLC Columns

Technical Note. Introduction

Mass Spectrometry. General Principles

Selecting an LC/MS Interface Becky Wittrig, Ph.D.

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Other Methods for Generating Ions 1. MALDI matrix assisted laser desorption ionization MS 2. Spray ionization techniques 3. Fast atom bombardment 4.

Mass Spectrometry (MS)

Molecular Mass Spectrometry

Exploration of the Quantitative Aspects of the MALDI TOFMS. Analysis of Peptides

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

1,1,3,3-Tetramethylguanidine-Promoted Ring-Opening Polymerization of N-Butyl N-Carboxyanhydride Using Alcohol Initiators

Author's final submitted manuscript Published as Rapid Commun. Mass Spectrom., vol. 15, pp (2001) DOI: /rcm.380

Supporting information

Ionization Methods in Mass Spectrometry at the SCS Mass Spectrometry Laboratory

Mass Spectrometry: Introduction

MALDI-TOF in the Characterizations of Dendritic-Linear Block Copolymers and Stars

Supplementary information

Matrix-assisted laser desorption/ionization

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

CHEM 429 / 529 Chemical Separation Techniques

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

CHAPTER A2 LASER DESORPTION IONIZATION AND MALDI

HPLC Background Chem 250 F 2008 Page 1 of 24

HPLC. High Performance Liquid Chromatography (HPLC) Harris Chapter 25

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Auxiliary Techniques Soft ionization methods

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Mass spectrometry: forming ions, to identifying proteins and their modifications Stephen Barnes, PhD

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Accurate Mass Analysis of Hydraulic Fracturing Waters

Mechanism of Insulin Emission in Matrix Assisted Laser Ionization

Using TOF for Screening and Quantitation of Sudan Red Colorants in Food Application

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

1) In what pressure range are mass spectrometers normally operated?

Chemistry 311: Topic 3 - Mass Spectrometry

RTILs as a Matrix in ME-SIMS

Mass spectrometry of proteins, peptides and other analytes: principles and principal methods. Matt Renfrow January 11, 2008

Microwave-assisted polyol synthesis of copper nanocrystals without additional protective agents

Quantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

William E. Wallace and Charles M. Guttman Polymers Division, National Institute of Standards and Technology, Gaithersburg, Maryland, USA

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

Mass spectrometry.

Supplementary Material (ESI) for Chemical Communications This journal is (c) The Royal Society of Chemistry Supporting information for:

Mass spectrometry: forming ions, to identifying proteins and their modifications Stephen Barnes, PhD

Qualitative Organic Analysis CH 351 Mass Spectrometry

Introduction to LC-MS

CHROMATOGRAPHY AND MASS SPECTROMETER

LECTURE-13. Peptide Mass Fingerprinting HANDOUT. Mass spectrometry is an indispensable tool for qualitative and quantitative analysis of

Supporting Information

Introduction to GC/MS

Effects of methanol on crystallization of water in the deeply super cooled region

MS Goals and Applications. MS Goals and Applications

The AccuTOF -DART 4G: The Ambient Ionization Toolbox

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Ch 13. Basics of Mass Spectrometry (I) : Principles & Ionization Sources

First Prebiotic Generation of a Ribonucleotide from Adenine, D Ribose and Trimetaphosphate

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Electrospray Ion Trap Mass Spectrometry. Introduction

Transcription:

Chromatographic Fidelity and Matrix /Analyte Solubility in Complex Polymer Systems using HPLC-MALD/I TOF MS Olumide Adebolu CHEM 395 March 1 st, 2007 Instructor : Prof J.Rusling

Overview 2 Introduction to MALDI Objective: To demonstrate compatibility of matrix/analyte mixtures and to also ascertain the Chromatographic fidelity in MALDI analysis of polymers. Approach: Coupling of HPLC with MALD/I TOF MS Hence the name LC-MALDI LC-MALDI interfaced using LC-Transform Series 600 (LabConnections, Inc.). Selective use of solvents gradient over varying temperature range. Results: Retention time/scan reproducibility over various samples analyzed and the signal to noise ratio. Capability of functional HPLC separation combined with automated MALDI analysis is demonstrated using K-GH Polyol (thermal dye-receiver polymer). Demonstrated advanced capability for differentiating materials.

3 Introduction to MALDI Since its discovery in the late 1980s,Matrix Assisted Laser Desorption Ionization (MALDI) has emerge as an important soft-ionization MS technique. Applications in many biologically related research areas (e.g.,protein,peptides,dna,carbohydrates) and materials-related fields (e.g., synthetic polymers) The fundamental mechanisms still remain unknown despite its routine usage

Introduction Cont d 4 MALDI experiment can be reduce to four different steps: Sample Prep: Molar ratio of matrix to analyte is large (e.g. between 10 2 : 1 and 10 6 : 1) Desorption: Pulsed laser beam (typically a Nitrogen laser,337nm) Ionization: Gas phase ionization reactions (Cationized,protonated,de-protonated or radical species) Mass Analysis: Time-of-flight (TOF),FTICR,QIT etc.

Sample Plate Sample Plate 1) Sample Preparation - Individual solutions of matrix material and analyte - Solutions are mixed (high matrix-to-analyte ratio) - Mixture is deposited onto the sample plate (solvent evaporated) - Analyte is homogeneously embedded within the matrix crystal (solid solution) UV Laser Pulse - Typically nitrogen laser (337 nm) - Matrix resonantly absorbs the laser energy 5 Matrix Analyte Cation + 2) Desorption - Matrix is desorbed off the surface, transferring the analyte molecules into the gas phase. - A supersonic expansion from the surface - the velocities of various components of the sample are found to be very similar 3) Ionization - Reactions occur in the dense plume - Gas-phase ionization - Formation of ions: cationized species, protonated species, deprotonated species, or radical cations 4) Mass Analysis - Time-of-Flight Mass Spectrometer

TOF Cont d 6 In linear TOF instrument, ions drift through the flight tube until they reach the detector. Because ions of different species in a mixture have different masses, they have different velocities based on the following equation: v = 2KE m ν=velocity, KE =kinetic energy, and m=mass t m = D Where D is the flight distance 2KE m = z 2Ut D 2 2 z=number of charge on an ion, U=accelerating voltage t=flight time

LCMS vs LC-MALDI 7 LC/MS HPLC Pump LC Column Mass Spectrometer m/z Liquid phase Gas Phase Ionization Retention time LC-MALDI HPLC Pump LC Column Spray interface m/z Mass Spectrometer Retention time Liquid phase Solid phase Gas Phase Ionization

LC-MALDI Interface 8 Beginning of separation Research & Development Laboratories, Eastman Kodak Company, Rochester, New York

LC-Interface Experimental Conditions Matrix Pump Pump 1: CHCA matrix 1 mg /ml in ACN:IPA Pump 2: ACN:IPA HPLC Column: Zorbax Eclipse XDB-C8 2.1mm x 150mm; 5µm A: Water B: ACN/IPA (1:1) Gradient: - 50% B 100%B in 20 min. at 250uL/min - Hold 100% B for 5 min at 250uL/min - 100% B 50% B in 0.1 min at 350uL/min - Hold 50% B for 5 min at 350uL/min Inj Vol.: 2uL Detection: DAD (monitor at 210 nm) Isocratic pumping of 50:50 (pump 1 : pump 2) Flow Rate: 100 ul/min Sprayer Temperature gradient: 172 o C at initial conditions to 133 o C at final conditions N 2 Gas Nebulization: 30 psi HO N O OH α-cyano-4-hydroxycinnamic acid (CHCA) 6 9

Application 10 Example used for Demonstration of Capability K-GH Polyol (low MW polymer used in Thermal dyereceiver) O CH 3 O O O O O O n CH 3 Important to have correct end-group chemistry Multiple end-group combinations have been observed Interest in pursuing functional separation

Direct MALD/I TOF MS of K-GH Polyol (no separation) 11 2371-06938-1a_raster 4 (0.503) Sb (30,30.00 ); Cm (1:49) 901.4 100 1287.5 TOF LD+ 1.06e5 % 902.4 1288.5 1673.7 In-Spec Material 2060.8 1289.5 1675.7 2446.8 2834.0 3220.1 3607.0 3993.2 4380.1 0 2371-06937-1raster 41 (5.436) Sb (30,30.00 ); Cm (1:49) 650.1 100 TOF LD+ 9.87e4 901.3 1287.4 Out of Spec Material % 902.3 1288.4 1673.6 1305.4 2060.7 1307.5 1693.5 2061.7 2446.8 2833.9 3220.1 3607.0 3993.2 0 m/z 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000

Direct MALD/I TOF MS of K-GH Polyol (no separation) 12 2371-06938-1a_raster 4 (0.503) Sb (30,30.00 ); Cm (1:49) 1287.5 100 A 386 Da 1288.5 % A 1673.7 TOF LD+ 9.41e4 In-Spec Material 0 2371-06937-1raster 41 (5.436) Sb (30,30.00 ); Cm (1:49) 1287.4 100 A % 1277.3 1289.5 1288.4 Z 1305.4 B 1419.6 C D Z 1306.4 1691.6 1277.2 1307.5 C X W B D 1693.5 C Y1323.4 1386.6 1541.6 1567.6 Y 1694.5 X W B D 1806.6 1928.7 0 m/z 1250 1300 1350 1400 1450 1500 1550 1600 1650 1700 1750 1800 1850 1900 1950 2000 2050 A 1673.6 1675.7 B 1806.7 C D TOF LD+ 5.63e4 Out of Spec Material

13 Spectral of PMMA 6300 using NaTFA as the cationization reagent with six matrixes (a) RA (b) DCTB (c) IAA (d) CHCA (e ) DHB (f) DHBQ Andrew, J.H.; William, J.E.; Robert, J.T.; Kelvin, G.O.; Anal.Chem. 2004, 76, 5157-5164

Results 14 DHBQ 2,5-dihydroxy-p-benzoquinone DHB 2,5-dihydroxybenzoic acid CHCA a-cyano-4-hydroxycinnamic acid IAA trans- indoleacrylic acid DCTB 2-[(2E)-3-(4-tert-butylphenyl)-2 methylpropenylidene] malanonitrile RA all-trans-retinoic acid Spectral of PS 7000 using AgTFA as the cationization reagent with six matrixes (a) RA (b) DCTB (c) IAA (d) CHCA (e ) DHB (f) DHBQ Andrew, J.H.; William, J.E.; Robert, J.T.; Kelvin, G.O.; Anal.Chem. 2004, 76, 5157-5164

Results Cont d 15 Spectral of PEG 10000 using NaTFA as the cationization reagent with six matrixes (a) RA (b) DCTB (c) IAA (d) CHCA (e ) DHB (f) DHBQ Andrew, J.H.; William, J.E.; Robert, J.T.; Kelvin, G.O.; Anal.Chem. 2004, 76, 5157-5164

16 Conclusion LC-MALDI retention time reproducibility is within a factor of 3, compared with conventional LC-DAD, despite the solid state transition. (Within a factor of 2 compared with conventional LC/MS). Demonstrated chromatographic fidelity for LC-MALDI compared to LC-DAD and LC-ELSD. Matrix-addition solvent effects were observed which compromised chromatographic fidelity. 3D MALDI Imaging being used to investigate the dynamics of this effect. Matching the RTs of the matrix and analyte consistently produced the best MALDI spectra with regard to S/N. The results presented here suggest that a good starting point for choosing the appropriate matrix for an unknown sample would be to match its relative polarity with that of the matrix.

17 Acknowledgements Andrew Hoteling & Bill Nichols Eastman Kodak Co. CHEM 395 Class of Spring 07!!

18 References Karas, M. Hillenkamp,F. Anal. Chem. 1988, 60, 2299-2301 Tanaka, K. Waki, H.; Ido, Y.; Akita, S.; Yoshido, Y,; Yoshido, T.; Rapid Commun.Mass Spectrom. 1988,2,151 Gidden, J.; Wyttenbach,T.; Jackson,A.T.; Scrivens, J.H.; Bowers, M.T.; J. Am. Chem. Soc. 2000,122,4692-4699 Gidden, J.; Bowers, M.T.; Jackson, A.T.; Scrivens, J.H.; J. Am. Soc. Mass Spectrom. 2002,13,499-505 Andrew, J.H.; William, J.E.; Robert, J.T.; Kelvin, G.O.; Anal.Chem. 2004, 76, 5157-5164 Cotter R.J.; 1997,Washington D.C.; ACS Professional Reference Books Opsal, R.B.; Owens, K.G.; Reilly, J.P.; Anal. Chem. 1985 57 1884-1889 Andrew J.H. PhD Thesis 2003