Similar documents
Pressure Display Controller

473-SHX Dew Point Mirror

473 Dew Point Hygrometer

473 Dew Point Hygrometer

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

RoHS. Versatile. X g. X 2 e

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

No /06e. Technical Manual Multistage-Temperature-/Differential Controller TAR x700

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Lufft MARWIS-UMB Mobil Advanced Road Weather Information Sensor

ED 701 General Industry Pressure Transmitter

ADI 2040 Process Analyzer

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

Acceleration/Velocity/Displacement VIBRATION METER

Infrared Hand-Held Thermometers

Hydraulic Pressure NAH Applications. Features. New generation available - refer to

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

VersaFlow Ultrasonic clamp-on Flowmeter Specifications

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

Automatic titrators, TitroMatic

Lufft MARWIS-UMB Mobile Advanced Road Weather Information Sensor

PAA-ANALYZERS PRINCIPLE OF OPERATION

ISEmax CAM40/CAS40. Technical Information

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

All-in-one or BOX industrial PC for autonomous or distributed applications

HANDHELD GAS ANALYZER DELTA 65

4 - Way Acceptance Low Maintenance Easy Installation Re - Programmable Flash ROM Auto Self -Adjusting Sensor System

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT

Operating Instructions for Digital Manometer. Model: MAN-SD

Lufft MARWIS-UMB Mobil Advanced Road Weather Information Sensor

WEATHER MULTI-SENSOR. Vaisala Weather Transmitter WXT510. Change the Way You Measure Weather

data sheet DONATELLO FAST General characteristics Rev. First emission - 01/07/ PRO02 code

3URGXFWLQIRUPDWLRQ 5HVHUYDWLRQRISURSHUW\ULJKWV

Book Automation for sectional doors up to 12 m 2 and overhead doors up to 11 m 2

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

WT 27 L-2 Laser Photoelectric proximity switches, background suppression -- DC. Dimensional drawing Adjustments possible WT 27L-2F 430

Heat Meter WR 200-D. 2 temperature inputs for Pt100 in four-wire circuit. Exact calculation of the heat parameters according IAPWS-IF97

Small Panel with matrix screen

One-hand ph/temperature measuring instrument

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

VK2 volume flow controller Overview

GS4000 DATASHEET JUNHO 2013

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

W250: Compact photoelectric switch series for a broad range of applications

IDENTIFICATION STS400

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits


DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

PHOENIX CONTACT - 04/2016. Features

INSTRUCTION AND MAINTENANCE MANUAL FOR TECHTROL COUNTER CONTROLLER & TOTALISER (TCCT)

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

variable flow dampers

Route and retain the clinometer cable so that it does not interfere with moving parts where the unit is mounted.

Impedance relay and protection assemblies

CTC 155 / 350 / 660 Dry-block calibrator

- compressed air plants (refrigerating/adsorption dryers) - granulate dryers - medical gases - non-corrosive gases, e. g. nitrogen

Technical Data Sheet DPT & DPIT-4005 SERIES DIFFERENTIAL PRESSURE TRANSDUCERS. Features. Description

Thermal Mass Flow Meter for Gases

610,- KERN ADB. Analytical balances. Quick-Finder Analytical balances. Large glass draught shield with 3 sliding doors

I-FORCE Ironless linear motors

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes

WATER ACTIVITY MEASUREMENT WATER ACTIVITY

Vaisala DRYCAP Hand-Held Dewpoint Meter DM70. Fast Response - Low Maintenance

PTA-427 BAROMETRIC PRESSURE TRANSDUCER OPERATOR S MANUAL

QUANTUM CONCEPT. Swimming User s Manual

Air velocity & IAQ measuring instruments

EVEN THE FINEST CANNOT ESCAPE. Wöhler SM 500 Suspended Particulate Analyser

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

NEW!! Reliable Chlorine Monitoring. Online Residual Chlorine Monitor. Detailed Specifications. Clean Water through Innovative Technology

Chilled Mirror Hygrometry

Infrared Hand-Held Thermometers

xlogic SuperRelay is a compact and expandable CPU replacing mini PLCs, multiple timers, relays and counters.

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

Air velocity & IAQ measuring instruments

PRODUCT CATALOGUE PREssURE switch

Relative pressure transmitter type 520

Industrial Pressure Transmitter

W 30 Photoelectric proximity switches: Clear signals even with low remission

Edgetech Instruments Inc.

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

Information Technology Solutions Neptune Datasheet

Industrial Pressure Transmitter

MODEL: CR002, CR003, CR004. ADC12 Display shield. Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Transcription:

65 0.26 Pascal-STV/ZB DIFFERENTIAL PRESSURE MEASUREMENT INSTRUMENT WITH ANALOG OUTPUT & DISPLAY 60 0.24 - CLEAN ROOMS - FILTER SYSTEMS - LAMINAR FLOWBOXES - AIR LOCKS 55 0.22 - FUME HOODS - ISOLATORS General information Bidirectional differential pressure measurement in pocket size WITH AUTOMATIC ZERO-POINT CALIBRATION 50 45 40 35 0.20 0.18 0.16 0.14 The Pascal-ST/ZB bidirectional differential pressure transmitters are mainly used for clean r o o m a p p l i c a t i o n s w h e r e accuracy and reliability are a must and space is limited. The measurement technology is based on the static principle with piezo-resistive bidirectional membrane. The state-of-the-art electronics and firmware in combination with the automatic zero-point calibration allow very accurate and stable readings without any drift. Depending on the application, various model types are available, with integrated alarm switches or with analogue output, with or without display. A l l i n s t r u m e n t s c a n b e programmed, configured and adjusted using the PascalTool- WIN PC software. The Pascal-STV/ZB disposes of a scalable and adjustable analogue output (ma or V). This makes it fi t for integration and adaptation to controlling systems (PLC). A digital output (RS-232) is also integrated by default. 30 0.12 Pascal-ST/ZB models are available for 2 measurement ranges, -25 to +25 and -100 to +100 Pa. This compact size product range among differential pressure measuring instruments excels by robust design and highest long-term performance. Features Applications 25 20 0.10 0.08 High cost effi ciency Excellent accuracy and reproducibility Automatic Zero-Point calibration No position dependency Measurement and control of low air differential pressures and air velocities: Industrial HVAC installations for processes Clean rooms applications Isolators, Laminar Flowboxes Versions : Long term stable Hospitals, operating rooms Pascal-STV 25 ZB : P/N 260 1241 Meas. range : -25...+25 Pa (bidirectional) Power supply : Signal output : 24VDC 0/4...20mA, 0/2...10V, RS-232 15 10 0.06 0.04 Easy adjustable and confi gurable by PC Password protection Easy mounting and startup Scalable & adjustable analogue outputs Laboratories, Testing rooms Monitoring systems Alarm visualisation by LED Pascal-STV 100 ZB : P/N 260 1242 Meas. range : Power supply : Signal output : -100...+100 Pa (bidirectional) 24VDC 0/4...20mA, 0/2...10V, RS-232 5 0.02 Integrated 2-line LCDisplay Possibility to measure the air velocity SWISS-MADE Quality Confi guration software PascalTool-WIN 0 Pa 0 in H 2 0 Technical data see overleaf

Technical data Type Pascal-STV 25 ZB Pascal-STV 100 ZB Part no. 260 1241 260 1242 Measurement range -25... +25 Pa -100... +100 Pa Max. permissible operating pressure +/- 25 Pa +/- 100 Pa Accuracy at 20 C typical ± 0.15 Pa typical ± 0.25 Pa Temperature effect max. ± 0.20 Pa (at constant operation temperature out of adjustment temperature) Max. resolution 0.1 Pa Measurement interval approx. 20 measurements / second Hysteresis < ± 0.15 Pa Offset-Drift under TLV conditions ± 0.15 Pa (with automatic zero-point calibration) Max. permissible overpressure ± 20 000 Pa Operating temperature 5... 45 C Display Dot matrix 2 line LCD (36 x 14 mm) Analogue outputs 0... 10 V / 2... 10 V (burden to ground >10 kohm) (scalable and adjustable) 0... 20 ma / 4... 20 ma (burden <500 Ohm) Digital interface RS-232 (ASCII-string, complex protocol) Power supply 10.5...35 VDC Power consumption max. 2.5 W (in operation) Protection IP 54 / EMC Measurement medium dry, not condensing, non aggressive gases Accessories + Spare parts Part no. External power supply 90...260 VAC 50/60 Hz -> 24VDC US/JP/EUR plug 252 4210 PascalTool Win CD (alternative as freeware as download from Novasina homepage) 111 6848 Confi guration cable for communication with Pascal instrument 111 6849 Factory calibration certifi cate on 3 measuring points (must be ordered separately) 111 7603 Customer specifi c confi guration 111 6074 Mobile dp calibrator and reference instrument CALIBOX 200 (range 0...200 Pa) 260 0538 Technical data subject to changes without notice Plug - P/N 252 4210 R S - 2 3 2 c a b l e 1. 5 m with D-Sub 9 - P/N 111 6849 005164.00 CALIBOX 200 - P/N 260 0538 Novasina AG, Neuheimstrasse 12, CH-8853 Lachen, Switzerland Phone +41-55-642 67 67, Fax +41-55-642 67 70, e-mail: info@novasina.ch, www.novasina.com

65 0.26 60 0.24 55 0.22 Pascal-STD/ZB DIFFERENTIAL PRESSURE MEASUREMENT I N S T R U M E N T W I T H A N A L O G O U T P U T - CLEAN ROOMS - LAMINAR FLOWBOXES - FUME HOODS - FILTER SYSTEMS - AIR LOCKS - ISOLATORS General information Bidirectional differential pressure measurement in pocket size WITH AUTOMATIC ZERO-POINT CALIBRATION 50 45 40 35 0.20 0.18 0.16 0.14 The Pascal-ST/ZB bidirectional differential pressure transmitters are mainly used for clean r o o m a p p l i c a t i o n s w h e r e accuracy and reliability are a must and space is limited. The measurement technology is based on the static principle with piezo-resistive bidirectional membrane. The state-of-the-art electronics and firmware in combination with the automatic zero-point calibration allow very accurate and stable readings without any drift. Depending on the application, various model types are available, with integrated alarm switches or with analogue output, with or without display. A l l i n s t r u m e n t s c a n b e programmed, configured and adjusted using the PascalTool- WIN PC software. The Pascal-STD/ZB disposes of a scalable and adjustable analogue output (ma or V). This makes it fi t for integration and adaptation to controlling systems (PLC). A digital output (RS-232) is also integrated by default. 30 0.12 Pascal-ST/ZB models are available for 2 measurement ranges, -25 to +25 and -100 to +100 Pa. This compact size product range among differential pressure measuring instruments excels by robust design and highest long-term performance. 25 0.10 Features Applications Versions : Pascal-STD 25 ZB : P/N 260 1243 Meas. range : -25...+25 Pa (bidirectional) Signal output : 0/4...20mA, 0/2...10V, RS-232 Pascal-STD 100 ZB : P/N 260 1244 Meas. range : -100...+100 Pa (bidirectional) Signal output : 0/4...20mA, 0/2...10V, RS-232 20 15 10 5 0.08 0.06 0.04 0.02 0 Pa 0 in H 2 0 High cost effi ciency Excellent accuracy and reproducibility Automatic Zero-Point calibration No position dependency Long term stable Easy adjustable and confi gurable by PC Password protection Easy mounting and startup Scalable & adjustable analogue outputs Alarm visualisation by LED Possibility to measure the air velocity SWISS-MADE Quality Measurement and control of low differential air pressures and air velocities: Industrial HVAC installations for processes Clean rooms applications Isolators, Laminar Flowboxes Hospitals, operating rooms Laboratories, Testing rooms Monitoring systems Confi guration software PascalTool-WIN Technical data see overleaf

Technical data Type Pascal-STD 25 ZB Pascal-STD 100 ZB Part no. 260 1243 260 1244 Measurement range -25... +25 Pa -100... +100 Pa Max. permissible operating pressure +/- 25 Pa +/- 100 Pa Accuracy at 20 C typical ± 0.15 Pa typical ± 0.25 Pa Temperature effect max. ± 0.20 Pa (at constant operation temperature out of adjustment temperature) Max. resolution 0.1 Pa Measurement interval approx. 20 measurements / second Hysteresis < ± 0.15 Pa Offset-Drift under TLV conditions ± 0.15 Pa (with automatic zero-point calibration) Max. permissible overpressure ± 20 000 Pa Operating temperature 5... 45 C Analogue outputs 0... 10 V / 2... 10 V (burden to ground >10 kohm) (scalable and adjustable) 0... 20 ma / 4... 20 ma (burden <500 Ohm) Digital interface RS-232 (ASCII-string, complex protocol) Power supply 10.5...35 VDC Power consumption max. 2.5 W (in operation) Protection IP 54 / EMC Measurement medium dry, not condensing, non aggressive gases Accessories + Spare parts Part no. External power supply 90...260 VAC 50/60 Hz -> 24VDC US/JP/EUR plug 252 4210 PascalTool Win CD (alternative as freeware as download from Novasina homepage) 111 6848 Confi guration cable for communication with Pascal instrument 111 6849 Factory calibration certifi cate on 3 measuring points (must be ordered separately) 111 7603 Customer specifi c confi guration 111 6074 Mobile dp calibrator and reference instrument CALIBOX 200 (range 0...200 Pa) 260 0538 Technical data subject to changes without notice Plug - P/N 252 4210 R S - 2 3 2 c a b l e 1. 5 m with D-Sub 9 - P/N 111 6849 005162.00 CALIBOX 200 - P/N 260 0538 Novasina AG, Neuheimstrasse 12, CH-8853 Lachen, Switzerland Phone +41-55-642 67 67, Fax +41-55-642 67 70, e-mail: info@novasina.ch, www.novasina.com

65 0.26 Pascal-STVS/ZB 60 55 0.24 0.22 DIFFERENTIAL PRESSURE MEASUREMENT INSTRUMENT WITH SWITCH RELAYS & DISPLAY - CLEAN ROOMS - LAMINAR FLOWBOXES - FUME HOODS - FILTER SYSTEMS - AIR LOCKS - ISOLATORS General information Bidirectional differential pressure measurement in pocket size WITH AUTOMATIC ZERO-POINT CALIBRATION 50 45 40 35 30 0.20 0.18 0.16 0.14 0.12 The Pascal-ST/ZB bidirectional differential pressure transmitters are mainly used for clean r o o m a p p l i c a t i o n s w h e r e accuracy and reliability are a must and space is limited. The measurement technology is based on the static principle with piezo-resistive bidirectional membrane. The state-of-the-art electronics and firmware in combination with the automatic zero-point calibration allow very accurate and stable readings without any drift. Pascal-ST/ZB models are available for 2 measurement ranges, -25 to +25 and -100 to +100 Pa. Depending on the application, various model types are available, with integrated alarm switches or with analogue output, with or without display. A l l i n s t r u m e n t s c a n b e programmed, configured and adjusted using the PascalTool- WIN PC software. The Pascal-STVS/ZB model type has 2 integrated programmable alarm switches and can be used for a 2-point control purposes e.g. for air lock access or fi lter saturation level monitoring. This compact size product range among differential pressure measuring instruments excels by robust design and highest long-term performance. Features Applications Versions : Pascal-STVS 25 ZB: P/N 260 1245 Meas. range : -25...+25 Pa (bidirectional) Alarm signals : 2 switch relays with adjustable time delay & hysteresis Pascal-STVS 100 ZB: P/N 260 1246 Meas. range : -100...+100 Pa (bidirectional) Alarm signals : 2 switch relays with adjustable time delay & hysteresis 25 20 15 10 5 0.10 0.08 0.06 0.04 0.02 High cost effi ciency Excellent accuracy and reproducibility Automatic Zero-Point calibration No position dependency Long term stable Easy adjustable and confi gurable by PC Password protection Easy mounting and startup 2 freely adjustable alarm outputs Alarm visualisation by LED Integrated 2-line LCDisplay Possibility to measure the air velocity SWISS-MADE Quality Measurement and control of low differential air pressures and air velocities: Industrial HVAC installations for processes Clean rooms applications Isolators, Laminar Flowboxes Hospitals, operating rooms Laboratories, Testing rooms Monitoring systems Confi guration software PascalTool-WIN 0 Pa 0 in H 2 0 Technical data see overleaf

Technical data Type Pascal-STVS 25 ZB Pascal-STVS 100 ZB Part no. 260 1245 260 1246 Measurement range -25... +25 Pa -100... +100 Pa Max. permissible operating pressure +/- 25 Pa +/- 100 Pa Accuracy at 20 C typical ± 0.15 Pa typical ± 0.25 Pa Temperature effect max. ± 0.20 Pa (at constant operation temperature out of adjustment temperature) Max. resolution 0.1 Pa Measurement interval approx. 20 measurements / second Hysteresis < ± 0.15 Pa Offset-Drift under TLV conditions ± 0.15 Pa (with automatic zero-point calibration) Max. permissible overpressure ± 20 000 Pa Operating temperature 5... 45 C Display Dot matrix 2 line LCD (36 x 14 mm) Switch relays Galvanic separated NO/NC, <= 48VAC/DC, 2A (max. 60 VA ohmic) Digital interface RS-232 (ASCII-string, complex protocol) Power supply 10.5...35 VDC Power consumption max. 2.5 W (in operation) Protection IP 54 / EMC Measurement medium dry, not condensing, non aggressive gases Accessories + Spare parts Part no. External power supply 90...260 VAC 50/60 Hz -> 24VDC US/JP/EUR plug 252 4210 PascalTool Win CD (alternative as freeware as download from Novasina homepage) 111 6848 Confi guration cable for communication with Pascal instrument 111 6849 Factory calibration certifi cate on 3 measuring points (must be ordered separately) 111 7603 Customer specifi c confi guration 111 6074 Mobile dp calibrator and reference instrument CALIBOX 200 (range 0...200 Pa) 260 0538 Technical data subject to changes without notice Plug - P/N 252 4210 R S - 2 3 2 c a b l e 1. 5 m with D-Sub 9 - P/N 111 6849 005166.00 CALIBOX 200 - P/N 260 0538 Novasina AG, Neuheimstrasse 12, CH-8853 Lachen, Switzerland Phone +41-55-642 67 67, Fax +41-55-642 67 70, e-mail: info@novasina.ch, www.novasina.com